Search NASA⌕ Search

SEARCH · Search NASA

Results for “direct simulation Monte Carlo methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Experimentally observed field–gas interaction in intense optical lattices

When a gas perturbed by a laser interference pattern, an optical lattice, exhibits a periodic modulation of its refractive index, strong Bragg diffraction of the perturbing light can occur. This scattering reduces the field's ability to further manipulate the gas. Experimental observations of Bragg scattering, evidence of a two-way coupling, are compared to the evolution of the light fields calculated by solutions to the wave equation. Comparison indicates momentum deposition as a prime contributor to the shape of the scattering function vs. lattice velocity, a rationale further supported through additional direct simulation Monte Carlo simulation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Ab Initio Calculation of Effective Sherman Functions in MeV Mott Scattering

A Mott polarimeter operating at energies from 1 to 3.5 MeV and at backward scattering angle of 164 degree has been installed at the MAMI accelerator. Its detection system is based on magnetic spectrometers allowing for efficient background suppression. The useful range of primary currents is between 10 nA and 100 {mu}A, hence adapted to the typical beam currents at MAMI. The reduction of analyzing power due to multiple scattering can be calculated directly from the cross sections with the help of Monte Carlo simulation.

43 PARTICLE ACCELERATORS↗

Stochastic Particle Real Time Analyzer (SPARTA) Validation and Verification Suite

This report presents the test cases used to verify, validate and demonstrate the features and capabilities of the first release of the 3D Direct Simulation Monte Carlo (DSMC) code SPARTA (Stochastic Real Time Particle Analyzer). The test cases included in this report exercise the most critical capabilities of the code like the accurate representation of physical phenomena (molecular advection and collisions, energy conservation, etc.) and implementation of numerical methods (grid adaptation, load balancing, etc.). Several test cases of simple flow examples are shown to demonstrate that the code can reproduce phenomena predicted by analytical solutions and theory. A number of additional test cases are presented to illustrate the ability of SPARTA to model flow around complicated shapes. In these cases, the results are compared to other well-established codes or theoretical predictions. This compilation of test cases is not exhaustive, and it is anticipated that more cases will be added in the future.

97 MATHEMATICS AND COMPUTING↗

Stochastic Particle Real Time Analyzer (SPARTA) Validation and Verification Suite

This report presents the test cases used to verify, validate and demonstrate the features and capabilities of the first release of the 3D Direct Simulation Monte Carlo (DSMC) code SPARTA (Stochastic Real Time Particle Analyzer). The test cases included in this report exercise the most critical capabilities of the code like the accurate representation of physical phenomena (molecular advection and collisions, energy conservation, etc.) and implementation of numerical methods (grid adaptation, load balancing, etc.). Several test cases of simple flow examples are shown to demonstrate that the code can reproduce phenomena predicted by analytical solutions and theory. A number of additional test cases are presented to illustrate the ability of SPARTA to model flow around complicated shapes. In these cases, the results are compared to other well-established codes or theoretical predictions. This compilation of test cases is not exhaustive, and it is anticipated that more cases will be added in the future.

97 MATHEMATICS AND COMPUTING↗

Production of high-energy gamma rays by cosmic ray interactions in the atmosphere and lunar surface

The production of gamma rays above 10 MeV by the interaction of cosmic rays in the atmosphere and the lunar surface is simulated using Monte Carlo methods. The calculation incorporates a new model of high-energy nucleon-nucleus interactions based on empirical fits to inclusive cross sections for the production of pions and nucleons. The atmospheric gamma ray flux is calculated as a function of direction, energy, and atmospheric depth. These calculations are compared with observations from balloons and from the SAS 2 satellite. Estimates of the flux of earth albedo electrons produced by cosmic ray interactions are presented. The lunar gamma ray albedo is calculated and compared with an upper limit based on SAS 2 measurements.

Morris, D. J.↗

Calculating Alpha Eigenvalues and Eigenfunctions with a Markov Transition Rate Matrix Monte Carlo Method

For a nuclear system in which the entire α-eigenvalue spectrum is known, eigenfunction expansion yields the time-dependent flux response to any arbitrary source. Applications in which this response is of interest include pulsed-neutron experiments, accelerator-driven subcritical systems, and fast burst reactors, where a steady-state assumption used in neutron transport is invalid for characterizing the time-dependent flux. To obtain the α-eigenvalue spectrum, the transition rate matrix method (TRMM) tallies transition rates describing neutron behavior in a discretized position-direction-energy phase space using Monte Carlo. Interpretation of the resulting Markov process transition rate matrix as the operator in the adjoint α-eigenvalue problem provides an avenue for determining a large finite set of α eigenvalues and eigenfunctions of a nuclear system. Results from the TRMM are verified using analytic solutions, time-dependent Monte Carlo simulations, and modal expansion from diffusion theory. For simplified infinite-medium and one-dimensional geometries, the TRMM accurately calculates eigenvalues, eigenfunctions, and eigenfunction expansion solutions. Applications and comparisons to measurements are made for the small fast burst reactor CALIBAN and the Fort St. Vrain high-temperature gas-cooled reactor. For large three-dimensional geometries, discretization of the large position-energy-direction phase space limits the accuracy of eigenfunction expansion solutions using the TRMM, but it can still generate a fair estimate of the fundamental eigenvalue and eigenfunction. These results show that the TRMM generates an accurate estimate of a large number of α eigenvalues. This is not possible with existing Monte Carlo–based methods.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Design and measurement methods for a lithium vapor box similarity experiment

The lithium vapor box divertor is a concept for handling the extreme divertor heat fluxes in magnetic fusion devices. In a baffled slot divertor, plasma interacts with a dense cloud of Li vapor which radiates and cools the plasma, leading to recombination and detachment. Before testing on a tokamak the concept should be validated: we plan to study detachment and heat redistribution by a Li vapor cloud in laboratory experiments.Mass changes and temperatures are measured to validate a Direct Simulation Monte Carlo model of neutral Li.The initial experiment involves a 5 cm diameter steel box containing 10g of Li held at 650 degrees C as vapor flows out a wide nozzle into a similarly-sized box at a lower temperature. Diagnosis is made challenging by the required material compatibility with lithium vapor. Vapor pressure is a steep function of temperature, so to validate mass flow models to within 10%, absolute temperature to within 4.5K is required. The apparatus is designed to be used with an analytical balance to determine mass transport. Details of the apparatus and methods of temperature and mass flow measurements are presented.

lithium vapor↗

On recontamination and directional-bias problems in Monte Carlo simulation of PDF turbulence models

Turbulent combustion can not be simulated adequately by conventional moment closure turbulence models. The difficulty lies in the fact that the reaction rate is in general an exponential function of the temperature, and the higher order correlations in the conventional moment closure models of the chemical source term can not be neglected, making the applications of such models impractical. The probability density function (pdf) method offers an attractive alternative: in a pdf model, the chemical source terms are closed and do not require additional models. A grid dependent Monte Carlo scheme was studied, since it is a logical alternative, wherein the number of computer operations increases only linearly with the increase of number of independent variables, as compared to the exponential increase in a conventional finite difference scheme. A new algorithm was devised that satisfies a restriction in the case of pure diffusion or uniform flow problems. Although for nonuniform flows absolute conservation seems impossible, the present scheme has reduced the error considerably.

Hsu, Andrew T.↗

Cascaded analysis of signal and noise propagation through a heterogeneous breast model

Purpose: The detectability of lesions in radiographic images can be impaired by patterns caused by the surrounding anatomic structures. The presence of such patterns is often referred to as anatomic noise. Others have previously extended signal and noise propagation theory to include variable background structure as an additional noise term and used in simulations for analysis by human and ideal observers. Here, the analytic forms of the signal and noise transfer are derived to obtain an exact expression for any input random distribution and the ''power law'' filter used to generate the texture of the tissue distribution. Methods: A cascaded analysis of propagation through a heterogeneous model is derived for x-ray projection through simulated heterogeneous backgrounds. This is achieved by considering transmission through the breast as a correlated amplification point process. The analytic forms of the cascaded analysis were compared to monoenergetic Monte Carlo simulations of x-ray propagation through power law structured backgrounds. Results: As expected, it was found that although the quantum noise power component scales linearly with the x-ray signal, the anatomic noise will scale with the square of the x-ray signal. There was a good agreement between results obtained using analytic expressions for the noise power and those from Monte Carlo simulations for different background textures, random input functions, and x-ray fluence. Conclusions: Analytic equations for the signal and noise properties of heterogeneous backgrounds were derived. These may be used in direct analysis or as a tool to validate simulations in evaluating detectability.

60 APPLIED LIFE SCIENCES↗

Tetris-inspired detector with neural network for radiation mapping

Abstract Radiation mapping has attracted widespread research attention and increased public concerns on environmental monitoring. Regarding materials and their configurations, radiation detectors have been developed to identify the position and strength of the radioactive sources. However, due to the complex mechanisms of radiation-matter interaction and data limitation, high-performance and low-cost radiation mapping is still challenging. Here, we present a radiation mapping framework using Tetris-inspired detector pixels. Applying inter-pixel padding for enhancing contrast between pixels and neural networks trained with Monte Carlo (MC) simulation data, a detector with as few as four pixels can achieve high-resolution directional prediction. A moving detector with Maximum a Posteriori (MAP) further achieved radiation position localization. Field testing with a simple detector has verified the capability of the MAP method for source localization. Our framework offers an avenue for high-quality radiation mapping with simple detector configurations and is anticipated to be deployed for real-world radiation detection.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurements of Nuclear Effects and the $\bar \nu_\mu +H \to \mu^+ + n$ Cross Section in MINERνA with Neutron Tagging

MINERνA, or Main INjector ExpeRiment for ν-A, at Fermilab, is an experimentdedicated to the study of neutrino-nucleus interactions in the GeV regime. Itsgoal is to illustrate the interplay between hadronic and nuclear physics and measure intranuclear dynamics crucial for the present and future neutrino oscillationmeasurements. We first measure a set of variables sensitive to how Monte Carlo(MC) simulations of neutrino-nucleus interactions implement binding energy andthen move on to measure the antineutrino CCQE cross section on the hydrogentargets in MINERνA’s CH detector. We have developed a method to preferentially select events on the hydrogen by comparing outgoing neutrons’ directions totheoretical neutron directions assuming two-body interactions. We measured thecross section, extracted the axial form factor, and performed a Z-expansion fit. Weobserve larger values in the axial form factor at high Q2than current best fits. Finally, we show a preliminary selection of events with both protons and neutrons toinvestigate nuclear processes responsible for producing these final states.

Cai, Tejin↗

Annealed Importance Sampling Reversible Jump MCMC algorithms

It will soon be 20 years since reversible jump Markov chain Monte Carlo (RJ-MCMC) algorithms have been proposed. They have significantly extended the scope of Markov chain Monte Carlo simulation methods, offering the promise to be able to routinely tackle transdimensional sampling problems, as encountered in Bayesian model selection problems for example, in a principled and flexible fashion. Their practical efficient implementation, however, still remains a challenge. A particular difficulty encountered in practice is in the choice of the dimension matching variables (both their nature and their distribution) and the reversible transformations which allow one to define the one-to-one mappings underpinning the design of these algorithms. Indeed, even seemingly sensible choices can lead to algorithms with very poor performance. The focus of this paper is the development and performance evaluation of a method, annealed importance sampling RJ-MCMC (aisRJ), which addresses this problem by mitigating the sensitivity of RJ-MCMC algorithms to the aforementioned poor design. As we shall see the algorithm can be understood as being an “exact approximation” of an idealized MCMC algorithm that would sample from the model probabilities directly in a model selection set-up. Such an idealized algorithm may have good theoretical convergence properties, but typically cannot be implemented, and our algorithms can approximate the performance of such idealized algorithms to an arbitrary degree while not introducing any bias for any degree of approximation. Our approach combines the dimension matching ideas of RJ-MCMC with annealed importance sampling and its Markov chain Monte Carlo implementation. We illustrate the performance of the algorithm with numerical simulations which indicate that, although the approach may at first appear computationally involved, it is in fact competitive.

annealed importance sampling↗

Design and measurement methods for a lithium vapor box similarity experiment

Here, the lithium vapor box divertor is a concept for handling the extreme divertor heat fluxes in magnetic fusion devices. In a baffled slot divertor, plasma interacts with a dense cloud of Li vapor which radiates and cools the plasma, leading to recombination and detachment. Before testing on a tokamak, the concept should be validated: we plan to study detachment and heat redistribution by a Li vapor cloud in laboratory experiments. Mass changes and temperatures are measured to validate a direct simulation Monte Carlo model of neutral Li. The initial experiment involves a 5 cm diameter steel box containing 10 g of Li held at 650 °C as vapor flows out a wide nozzle into a similarly sized box at a lower temperature. Diagnosis is made challenging by the required material compatibility with lithium vapor. Vapor pressure is a steep function of temperature, so to validate mass flow models to within 10%, absolute temperature to within 4.5 K is required. The apparatus is designed to be used with an analytical balance to determine mass transport. Details of the apparatus and methods of temperature and mass flow measurements are presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A fast Monte Carlo cell-by-cell simulation for radiobiological effects in targeted radionuclide therapy using pre-calculated single-particle track standard DNA damage data

Introduction: We developed a new method that drastically speeds up radiobiological Monte Carlo radiation-track-structure (MC-RTS) calculations on a cell-by-cell basis. Methods: The technique is based on random sampling and superposition of single-particle track (SPT) standard DNA damage (SDD) files from a “pre-calculated” data library, constructed using the RTS code TOPAS-nBio, with “time stamps” manually added to incorporate dose-rate effects. This time-stamped SDD file can then be input into MEDRAS, a mechanistic kinetic model that calculates various radiation-induced biological endpoints, such as DNA double-strand breaks (DSBs), misrepairs and chromosomal aberrations, and cell death. As a benchmark validation of the approach, we calculated the predicted energy-dependent DSB yield and the ratio of direct-to-total DNA damage, both of which agreed with published in vitro experimental data. We subsequently applied the method to perform a superfast cell-by-cell simulation of an experimental in vitro system consisting of neuroendocrine tumor cells uniformly incubated with 177 Lu. Results and discussion: The results for residual DSBs, both at 24 and 48 h post-irradiation, are in line with the published literature values. Our work serves as a proof-of-concept demonstration of the feasibility of a cost-effective “in silico clonogenic cell survival assay” for the computational design and development of radiopharmaceuticals and novel radiotherapy treatments more generally.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Multiscale Mathematics for Plasma Kinetics Spanning Multiple Collisionality Regimes (Final Technical Report)

This is the Final Technical Report on this grant. The subject of this grant is accelerated simulation for plasma kinetics, in particular for Coulomb collisions in a plasma. The goal of this project is the development of accelerated simulation methods for plasma kinetics and the application of these methods to prob lems of interest for plasma fusion. Specifically, this project is developing methods for simulation of Coulomb collisions between charged particles. Collisional effects can be significant in the edge plasma of a fusion device, but correct simulation of the collisional effects is a computational bottleneck for current simulation methods. We developed two approaches to acceleration of simulation for Coulomb collisions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Poster — Thur Eve — 45: Comparison of different Monte Carlo methods of scoring linear energy transfer in modulated proton therapy beams

In this work, we demonstrate inconsistencies in commonly used Monte Carlo methods of scoring linear energy transfer (LET) in proton therapy beams. In particle therapy beams, the LET is an important parameter because the relative biological effectiveness (RBE) depends on it. LET is often determined using Monte Carlo techniques. We used a realistic Monte Carlo model of a proton therapy nozzle to score proton LET in spread-out Bragg peak (SOBP) depth-dose distributions. We used three different scoring and calculation techniques to determine average LET at varying depths within a 140 MeV beam with a 4 cm SOBP and a 250 MeV beam with a 10 cm SOBP. These techniques included fluence-weighted (Φ-LET) and dose-weighted average (D-LET) LET calculations from: 1) scored energy spectra converted to LET spectra through a lookup table, 2) directly scored LET spectra and 3) accumulated LET scored ‘on-the-fly’ during simulations. All protons (primary and secondary) were included in the scoring. Φ-LET was found to be less sensitive to changes in scoring technique than D-LET. In addition, the spectral scoring methods were sensitive to low-energy (high-LET) cutoff values in the averaging. Using cutoff parameters chosen carefully for consistency between techniques, we found variations in Φ-LET values of up to 1.6% and variations in D-LET values of up to 11.2% for the same irradiation conditions, depending on the method used to score LET. Variations were largest near the end of the SOBP, where the LET and energy spectra are broader.

07 ISOTOPE AND RADIATION SOURCES↗

Calculation of the replacement correction factors for ion chambers in megavoltage beams by Monte Carlo simulation

This article describes four methods of calculating the replacement correction factor, P{sub repl} (or the product p{sub cav}p{sub dis} in the IAEA's notation), for a plane-parallel chamber in both electron and photon beams, and for a Farmer chamber in photon beams, by using the EGSnrc Monte Carlo code. The accuracy of underlying assumptions and relative merits of each technique are assessed. With careful selection of parameters it appears that all four methods give reasonable answers although the direct methods are more intellectually satisfying and more accurate in some cases. The direct methods are shown to have an accuracy of 0.1% when appropriate calculation parameters are selected. The depth dependence of P{sub repl} for the NACP02 plane-parallel chamber has been calculated in both 6 and 18 MeV electron beams. At the reference depth (0.6R{sub 50}-0.1 cm) P{sub repl} is 0.9964 for the 6 MeV beam and 1.0005 for the 18 MeV beam for this well-guarded chamber; at the depth of maximum dose for the 18 MeV beam, P{sub repl} is 1.0010. P{sub repl} is also calculated for the NACP02 chamber and a Farmer chamber (diameter 6 mm) at a depth of 5 cm in a {sup 60}Co photon beam, giving values of 1.0063 and 0.9964, respectively. For the Farmer chamber, P{sub repl} is about half a percent higher than the value (0.992) recommended by the AAPM dosimetry protocol. It is found that the dosimetry protocols may have adopted an incorrect value of P{sub repl} for cylindrical chambers in photon beams. The nonunity values of P{sub repl} for plane-parallel chambers in lower energy electron beams imply a variety of values used in dosimetry protocols must be reassessed.

61 RADIATION PROTECTION AND DOSIMETRY↗

Electrostatic focal spot correction for x-ray tubes operating in strong magnetic fields

Purpose: A close proximity hybrid x-ray/magnetic resonance (XMR) imaging system offers several critical advantages over current XMR system installations that have large separation distances (∼5 m) between the imaging fields of view. The two imaging systems can be placed in close proximity to each other if an x-ray tube can be designed to be immune to the magnetic fringe fields outside of the MR bore. One of the major obstacles to robust x-ray tube design is correcting for the effects of the MR fringe field on the x-ray tube focal spot. Any fringe field component orthogonal to the x-ray tube electric field leads to electron drift altering the path of the electron trajectories. Methods: The method proposed in this study to correct for the electron drift utilizes an external electric field in the direction of the drift. The electric field is created using two electrodes that are positioned adjacent to the cathode. These electrodes are biased with positive and negative potential differences relative to the cathode. The design of the focusing cup assembly is constrained primarily by the strength of the MR fringe field and high voltage standoff distances between the anode, cathode, and the bias electrodes. From these constraints, a focusing cup design suitable for the close proximity XMR system geometry is derived, and a finite element model of this focusing cup geometry is simulated to demonstrate efficacy. A Monte Carlo simulation is performed to determine any effects of the modified focusing cup design on the output x-ray energy spectrum. Results: An orthogonal fringe field magnitude of 65 mT can be compensated for using bias voltages of +15 and −20 kV. These bias voltages are not sufficient to completely correct for larger orthogonal field magnitudes. Using active shielding coils in combination with the bias electrodes provides complete correction at an orthogonal field magnitude of 88.1 mT. Introducing small fields (<10 mT) parallel to the x-ray tube electric field in addition to the orthogonal field does not affect the electrostatic correction technique. However, rotation of the x-ray tube by 30° toward the MR bore increases the parallel magnetic field magnitude (∼72 mT). The presence of this larger parallel field along with the orthogonal field leads to incomplete correction. Monte Carlo simulations demonstrate that the mean energy of the x-ray spectrum is not noticeably affected by the electrostatic correction, but the output flux is reduced by 7.5%. Conclusions: The maximum orthogonal magnetic field magnitude that can be compensated for using the proposed design is 65 mT. Larger orthogonal field magnitudes cannot be completely compensated for because a pure electrostatic approach is limited by the dielectric strength of the vacuum inside the x-ray tube insert. The electrostatic approach also suffers from limitations when there are strong magnetic fields in both the orthogonal and parallel directions because the electrons prefer to stay aligned with the parallel magnetic field. These challenging field conditions can be addressed by using a hybrid correction approach that utilizes both active shielding coils and biasing electrodes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗