Examining the Effect of Cumulative Low Dose Radiation on TK6 Human Lymphoblastoid Cells During Simulated Microgravity
No abstract available
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
No abstract available
Power systems designed for use in NASA space missions are required to work reliably under harsh conditions including radiation, thermal cycling, and extreme temperature exposures. Silicon carbide devices show great promise for use in future power electronics systems, but information pertaining to performance of the devices in the space environment is very scarce. A silicon carbide N-channel enhancement-mode power MOSFET called the CMF20120 is of interest for use in space environments. Samples of the device were exposed to radiation followed by long-term thermal cycling to address their reliability for use in space applications. The results of the experimental work are presentd and discussed.
The gate all around transistor is investigated through experiment. The suspended silicon nanowire for the next generation is fabricated on bulk substrate by plasma etching method. The scallop pattern generated by Bosch process is utilized to form a floating silicon nanowire. By combining anisotropic and istropic silicon etch process, the shape of nanowire is accurately controlled. From the suspended nanowire, the gate all around transistor is demonstrated. As the silicon nanowire is fully surrounded by the gate, the device shows excellent electrostatic characteristics.
No abstract available
INTRODUCTION As with most computational analyses, a tradeoff exists between problem complexity, resource availability and response accuracy when modeling radiation transport from the source to a detector. The largest amount of analyst time for setting up an analysis is often spent ensuring that any simplifications made have minimal impact on the results. The vehicle shield geometry of interest is typically simplified from the original CAD design in order to reduce computation time, but this simplification requires the analyst to "re-draw" the geometry with a limited set of volumes in order to accommodate a specific radiation transport software package. The resulting low-fidelity geometry model cannot be shared with or compared to other radiation transport software packages, and the process can be error prone with increased model complexity. The work presented here demonstrates the use of the DAGMC (Direct Accelerated Geometry for Monte Carlo) Toolkit from the University of Wisconsin, to model the impacts of several space radiation sources on a CAD drawing of the US Lab module. METHODS The DAGMC toolkit workflow begins with the export of an existing CAD geometry from the native CAD to the ACIS format. The ACIS format file is then cleaned using SpaceClaim to remove small holes and component overlaps. Metadata is then assigned to the cleaned geometry file using CUBIT/Trelis from csimsoft (Registered Trademark). The DAGMC plugin script removes duplicate shared surfaces, facets the geometry to a specified tolerance, and ensures that the faceted geometry is water tight. This step also writes the material and scoring information to a standard input file format that the analyst can alter as desired prior to running the radiation transport program. The scoring results can be transformed, via python script, into a 3D format that is viewable in a standard graphics program. RESULTS The CAD model of the US Lab module of the International Space Station, inclusive of all the racks and components, was simplified to remove holes and volume overlaps. Problematic features within the drawing were also removed or repaired to prevent runtime issues. The cleaned drawing was then run through the DAGMC workflow to prepare for analysis. Pilot tests modeling transport of 1GeV proton and 800MeV/A oxygen sources show that reasonable results are converged upon in an acceptable amount of overall computation time from drawing preparation to data analysis. The FLUKA radiation transport code will next be used to model both a GCR and a trapped radiation source. These results will then be compared with measurements that have been made by the radiation instrumentation deployed inside the US Lab module. DISCUSSION Early analyses have indicated that the DAGMC workflow is a promising toolkit for running vehicle geometries of interest to NASA through multiple radiation transport codes. In addition, recent work has shown that a realistic human phantom, provided via a subcontract with the University of Florida, can be placed inside any vehicle geometry for a combinatorial analysis. This added functionality gives the user the ability to score various parameters at the organ level, and the results can then be used as input for cancer risk models.
A data device includes a memory having a plurality of memory cells configured to store data values in accordance with a predetermined rank modulation scheme that is optional and a memory controller that receives a current error count from an error decoder of the data device for one or more data operations of the flash memory device and selects an operating mode for data scrubbing in accordance with the received error count and a program cycles count.
A combination of spaceflight-relevant factors (fluid-shift and radiation) created a different gene expression profile than either factor individually. Some gene pathways including reduced transcriptional machinery, increased neurogenesis and neuropeptide production, and dysregulated cell structure and cell signaling. Gene expression differences can persist for at least 4 months after a 21- day exposure to a combination of fluid-shift and radiation in the brain tissue of mice. Brain-related transcriptional changes are dynamic during readaptation phase from exposure to spaceflight-like conditions, which may lead to long-term neurological consequences.
No abstract available
Explore the source record for details and available documents.
This paper discusses the effect of ionizing radiation on two types of deformable MEMS mirrors.
Explore the source record for details and available documents.
Explore the source record for details and available documents.