Search NASA⌕ Search

SEARCH · Search NASA

Results for “electrical connectivity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Controlled workplace charging of electric vehicles: The impact of rate schedules on transformer aging

To accelerate adoption of non-residential charging for electric vehicles, sites must maximize utilization of existing electrical infrastructure. In this study we model electric vehicle charging at a workplace using real charging data and evaluate the lifetime of the site’s transformer as the number of charging stations is incrementally increased. We implement and compare a range of control schemes for workplace charging including minimizing the peak load, capping the total load, minimizing bills under different rate structures with time-of-use energy costs and demand charges, and directly minimizing the transformer’s aging. These are compared by the number of vehicles they allow the transformer to support, the transformer’s health, and the operator’s electricity bill. We draw a connection between minimizing the peak load and improving the transformer’s health. We observe that minimizing the electricity bill is the best scheme by both criteria when the bill includes a demand charge; in our experiment it allowed the infrastructure to support over 67% more cars than under uncontrolled charging. To protect the transformer we recommend that demand charges or capacity management be applied to parking lots of charging electric vehicles with high infrastructure utilization, and operators schedule charging to minimize their electricity bills.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Model-Based Framework to Optimize Charger Station Deployment for Battery Electric Vehicles

The development of battery electric vehicles (BEVs) is accelerating due to their environmental advantages over gasoline and diesel-powered vehicles, including a decrease in air pollution and an increase in energy efficiency. The deployment of charging infrastructure will need to increase to keep pace with demand, especially for large commercial vehicles for which few public chargers currently exist. In this paper, a new flexible framework is proposed for optimizing the placement of charging stations for BEVs, within which different physical models and optimization techniques may be used. Furthermore, a set of metrics is suggested to help enforce complex constraints and facilitate direct comparison between different optimization techniques. Unlike many existing charger placement techniques, the proposed method directly considers the historical driving patterns on a vehicle-by-vehicle basis, using transparent models to assess impacts of candidate charger placements, thus improving the explainability of the results. In the developed framework, modeled BEVs are first generated along the road network to mimic historical traffic data and are simulated traveling along a given route according to a simplified vehicle model. During the simulation, the charger placement problem is initially relaxed to allow vehicles to charge at any node along the road network, and vehicle states are tracked to assess areas of high charging demand. Charging stations are then placed based on the results of the relaxed simulation, and suggested placements are evaluated via road network simulation with fixed charger locations. This proposed framework is applied to a sample problem of placing charging stations along five major highway corridors for Class 8 over-the-road electric trucks. A novel mixed integer programming (MIP) formulation is proposed to optimize charger placements based upon the expected charging demand. Constraints were imposed on the final placement results to limit expected wait times at each station and ensure a minimum threshold of trucking routes are viable for BEVs. The results demonstrate the flexibility and potential effectiveness of the developed model-based framework for scalable charger station deployment.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Inflight IFR procedures simulator

An inflight IFR procedures simulator for generating signals and commands to conventional instruments provided in an airplane is described. The simulator includes a signal synthesizer which generates predetermined simulated signals corresponding to signals normally received from remote sources upon being activated. A computer is connected to the signal synthesizer and causes the signal synthesizer to produce simulated signals responsive to programs fed into the computer. A switching network is connected to the signal synthesizer, the antenna of the aircraft, and navigational instruments and communication devices for selectively connecting instruments and devices to the synthesizer and disconnecting the antenna from the navigational instruments and communication device. Pressure transducers are connected to the altimeter and speed indicator for supplying electrical signals to the computer indicating the altitude and speed of the aircraft. A compass is connected for supply electrical signals for the computer indicating the heading of the airplane. The computer upon receiving signals from the pressure transducer and compass, computes the signals that are fed to the signal synthesizer which, in turn, generates simulated navigational signals.

Parker, L. C.↗

Audi e-tron Green Light Optimized Speed Advisory On-Road Data

To aid researchers in studying the capabilities and benefits of vehicle-to-infrastructure communication, Argonne National Laboratory collected a robust set of on-road driving data of the Audi Green Light Optimized Speed Advisory (GLOSA) system implemented in the e-tron battery electric vehicle. This dataset includes 33 tests, each roughly 27 miles in length and roughly 45 to 75 minutes in duration. The team selected Kane County Highway Route 34 from Main Street in Batavia, Illinois to Middlecreek Lane in St. Charles, Illinois as the route do to its high density of GLOSA-active lights and the most opportunities to observe the system per hour of test time. The data include parameters from the following sources: GLOSA system driving the dash indicators, multiple powertrain parameters including real-time battery power/energy consumption, GPS, front radar gap, and rear radar gap. ![audio-e-tron image](audi-e-tron.jpg)

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

National Reactor Innovation Center (NRIC) Grid Connection Roadmap

In an effort to define the roadmap for establishing the necessary electrical infrastructure at the Idaho National Laboratory to fully support connection of NRIC reactors, this roadmap serves to identify the current forecasted reactors planned for installation at INL and provide a consolidated list of the identified infrastructure improvements that will be necessary to support testing of NRIC reactors. Additionally, the roadmap will leverage this information to establish an integrated timeline to support detailed planning and execution of system improvements. To drive this planning, requirements, as derived from authoritative sources, will be identified. A clear definition of impacted stakeholders will be established, as well as a list of risks that will need to be managed as the program moves forward.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

PV Field Reliability Status--Analysis of 100,000 Solar Systems

In this paper, we analyzed annual production data from 100 000 photovoltaic systems as well as comments relating to their performance and maintenance. Our analysis revealed that 80% to 90% of all systems performed within 10% of the predicted production or better. Also, 56% of the systems were still performing above P50 or the median at 5 years. However, a small but significant tail of about 7000 systems perform below P90 expectations. In general, residential systems have a lower rate of failure than utility or commercial systems. Despite higher rates of component failures, utility systems lose less power than residential or commercial systems. This outcome is likely due to closer monitoring and better operations and maintenance practices. Inverters are still the components that reportedly fail most often (4%-6%), but other failures such as unspecified repair and meters cause more production loss. Reported module failures are relatively rare (0.2%) and are within the range of historical values. Installation quality affects performance and safety as indicated by data showing connector, wiring, breaker, and fuse failures due to undersizing, electrical design, and improper connection. Lastly, early detection of degradation and proactive response resulted in less impact on production than reactive, unplanned repairs.

14 SOLAR ENERGY↗

Impact of climate change on water availability and its propagation through the Western U.S. power grid

Climate impact assessment for power systems has tended to focus on the effects of water availability on generation without explicitly considering how these impacts propagate through the interconnected grid to affect generation in other locations. We investigate the impact of projected water availability on the operations of the contemporary Western U.S. power grid, focusing specifically on regional interdependencies. Hydrologic simulations derived from three GCMs (CCSM4, INMCM4 and GFDL-CM3) and two radiative scenarios (RCP4.5 and RCP8.5) are used to force a large-scale, distributed water management model (MOSART-WM), which translates water availability into power generation constraints at hydropower plants and water-dependent thermo-electric plants. Power system dynamics are evaluated using the production cost model PLEXOS. We find that the inter-regional connections across the Western U.S. electricity infrastructure are key in managing drastic variations in regional water availability. Net generation in the Northwest and Northern California is substantially sensitive to local water availability. Generation from the Desert Southwest emerges as a critical resource to compensate for variations in water availability in those regions. Climate change impacts on Northwestern water availability therefore drive future changes in other regions’ generation and regional power flows. The large inter-annual hydrological variability of Northern California exacerbates grid stress arising from long-term changes in water availability in the Northwest. While the regional power flow directions seem insensitive to long-term variations in water availability, the analysis highlights the need to consider other compounding regional factors such as changes in Southern California net load or changes in regional fuel prices.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Programmable intrusion detection for distributed energy resources in cyber–physical networked microgrids

We present a programmable intrusion detection method is presented to identify the malicious attacks to distributed energy resources (DERs) in the cyber-physical networked microgrids. The proposed method injects small programmable signals into the system and uses the response to identify abnormal conditions. Because of the low or even zero inertia induced by integrations of DER power-electronic-interfaces, microgrids have very limited resilience capability; and thus, being sensitive to attacks. One microgrid's malfunction caused by attacks can easily propagate to its neighboring systems when several microgrids are connected, leading to catastrophic electricity supply failures. Through the presented method, malicious intrusions can be effectively detected, located, and defended for securing microgrids. Theoretical derivations are provided to define the programmable detection rules. The detection rule is easy and flexible to update, making it difficult for attack actors to gain the knowledge of the detection rules, in order to avoid being detected. Numerical results on a cyber-physical networked microgrids system show that the proposed method is effective and efficient in precisely locating intrusion attacks to the microgrids system.

42 ENGINEERING↗

Suppressed electric quadrupole collectivity in 49 Ti

Single-step Coulomb excitation of 46,48,49,50 Ti is presented. A complete set of E2 matrix elements for the quintuplet of states in 49 Ti, centred on the core excitation, was measured for the first time. A total of nine E2 matrix elements are reported, four of which were previously unknown. $^{49}_{22}$Ti 27 shows a 20% quenching in electric quadrupole transition strength as compared to its semi-magic $^{50}_{22}$Ti 28 neighbour. This 20% quenching, while empirically unprecedented, can be explained with a remarkably simple two-state mixing model, which is also consistent with other ground-state properties such as the magnetic dipole moment and electric quadrupole moment. A connection to nucleon transfer data and the quenching of single-particle strength is also demonstrated. The simplicity of the 49 Ti- 50 Ti pair (i.e., approximate single-j 0 7/2 valence space and isolation of yrast states from non-yrast states) provides a unique opportunity to disentangle otherwise competing effects in the ground-state properties of atomic nuclei, the emergence of collectivity, and the role of proton-neutron interactions.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Rural EVSE Planning and Analysis

The dataset includes detailed anonymized public charging station usage from several rural stations on the ChargePoint and Shell Recharge Solutions (formerly Greenlots) networks situated in and around Athens, Ohio, a rural Appalachian community. Both Level 2 and DC fast charging stations are represented. Historical data in the set date back to 2019; additional data will be uploaded semiannually until the project's completion in 2023. Each charging session recorded includes information on date and time, location, charging station level, session duration, energy delivered, and fuel savings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Specifying Calibration of Energy-Measuring Equipment

Instruments and standards need to be calibrated periodically to ensure that their use yields accurate measurements. Calibration needs, however, vary in sophistication, based on user expectations. This white paper reviews calibration terminology and standards, and describes best practices that have been developed for a) calibrating measurement equipment to ensure some known level of accuracy, and b) accrediting calibration service providers. Calibration is discussed in the context of metrological traceability, and excerpts from laboratory scopes of accreditation are shared to reveal the diversity of terminology and format among them. In an effort to aid those who currently calibrate measuring equipment or who have new or changing needs for calibrating measuring equipment, rationale is provided for why a specification might be used to request calibration services that meet specific test needs. Given the growing interest in using data to manage the energy consumption of systems, and the increasing number and variety of systems (e.g., building, computing) that can report such information, use cases requiring energy data are used to facilitate further discussion and provide examples. Commercially available service providers who are accredited for energy-measuring equipment calibration are compared and contrasted, and a specification template that might be used for requesting this calibration is presented. The specification template should be tailored to meet each user’s needs. To illustrate, an example set of energy-measuring-equipment test conditions (reflecting the planned usage of the device to be calibrated) is used to develop a customized calibration specification, and commercially available service providers are assessed in terms of their qualifications for calibration to that particular implementation of the specification template.

47 OTHER INSTRUMENTATION↗

Energy-Efficient Maneuvering of Connected and Automated Vehicles (CAVs) with Situational Awareness at Intersections (Final Progress Report)

The increased development of Connected and Automated Vehicle (CAV) systems, currently used for safety and driver convenience, presents new opportunities to improve the energy efficiency of vehicles. Southwest Research Institute (SwRI) achieved a 20% energy consumption reduction in a 2017 Toyota Prius Prime plug-in hybrid by using connectivity (V2V, V2I, V2X) as part of the Next Generation Energy Technologies for Connected and Automated on-Road Vehicles (NEXTCAR) program. The energy consumption gains were achieved by a combination of vehicle dynamics and powertrain control algorithms with a focus on SAE L1 and L2 automated vehicles where a human is still responsible for safe operation. SwRI is now involved in NEXTCAR-II, focusing on energy-efficient control tech for SAE Level 4/5 automated vehicles, aiming for a 30% energy reduction compared to stock hybrids. The rise of Mobility as a Service (MaaS) is driving investments in L4 and L5 automated vehicles. A study by the University of Michigan shows these vehicles might increase energy use and emissions by 3-20%. Technology similar to NEXTCAR can enhance energy efficiency in highly automated vehicles, leveraging improved sensing and actuation capabilities. While the NEXTCAR programs targeted energy efficiency improvements for a single vehicle, this program adopts a more expansive approach. It places its focus on understanding and testing the cumulative effects within a region or corridor, aiming to assess how a subset of vehicles equipped with NEXTCAR-style technologies influence the overall energy consumption of all vehicles traveling within that area. Additionally, the program explores infrastructure-based mobility solutions to optimize efficiency, and seeks to understand and quantify public perception and likelihood of technology adoption.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Overview of Building Electrification Technologies and Market Opportunities

This report provides an overview of building electrification drivers and select building electrification technologies and their markets and performance. Covered topics: Building Electrification Drivers and Context; Heat Pumps for Space Conditioning; Heat Pump Market Opportunities; Life Cycle GHG Emissions Impacts of Heat Pump Space Conditioning Technologies; Heat Pump Water Heaters; Electrification of Gas Loads: Commercial and Residential; Residential Panel Capacity; Electric Vehicle Impacts and Connections to Buildings; and Building Envelope Improvements and Thermal Energy Storage (TES) Opportunities.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Efficient, reliable and cost-effective reversible solid oxide cell technology for hydrogen and electricity production

This report summarizes the work performed by University of California San Diego (UCSD) – OxEon Energy LLC (OxEon) for the U. S. Department of Energy/National Energy Technology Laboratory (DOE/NETL) under Cooperative Agreement DE-FE0031940 entitled “Efficient, Reliable and Cost Effective Reversible Solid Oxide Cell Technology for Hydrogen and Electricity Production”. This reversible solid oxide cell (RSOC) technology has two main novel elements: (i) a compact and low-cost stack architecture that consists of multi-cell cell modules in electrical parallel and series connections and (ii) high performance and fuel-flexible reversible cells with electrodes or all components made by sputtering deposition process for efficient operation in both fuel cell (power generation) and electrolysis (hydrogen production) modes.

30 DIRECT ENERGY CONVERSION↗

Cybersecurity Considerations for Grid-Connected Batteries with Hardware Demonstrations

The share of renewable and distributed energy resources (DERs), like wind turbines, solar photovoltaics and grid-connected batteries, interconnected to the electric grid is rapidly increasing due to reduced costs, rising efficiency, and regulatory requirements aimed at incentivizing a lower-carbon electricity system. These distributed energy resources differ from traditional generation in many ways including the use of many smaller devices connected primarily (but not exclusively) to the distribution network, rather than few larger devices connected to the transmission network. DERs being installed today often include modern communication hardware like cellular modems and WiFi connectivity and, in addition, the inverters used to connect these resources to the grid are gaining increasingly complex capabilities, like providing voltage and frequency support or supporting microgrids. To perform these new functions safely, communications to the device and more complex controls are required. The distributed nature of DER devices combined with their network connectivity and complex controls interfaces present a larger potential attack surface for adversaries looking to create instability in power systems. To address this area of concern, the steps of a cyberattack on DERs have been studied, including the security of industrial protocols, the misuse of the DER interface, and the physical impacts. These different steps have not previously been tied together in practice and not specifically studied for grid-connected storage devices. In this work, we focus on grid-connected batteries. We explore the potential impacts of a cyberattack on a battery to power system stability, to the battery hardware, and on economics for various stakeholders. We then use real hardware to demonstrate end-to-end attack paths exist when security features are disabled or misconfigured. Our experimental focus is on control interface security and protocol security, with the initial assumption that an adversary has gained access to the network to which the device is connected. We provide real examples of the effectiveness of certain defenses. This work can be used to help utilities and other grid-connected battery owners and operators evaluate the severity of different threats and the effectiveness of defense strategies so they can effectively deploy and protect grid-connected storage devices.

25 ENERGY STORAGE↗

Portable tool cleans pipes and tubing

Portable tool cleans and polishes the external surfaces of tubes and pipes without contaminating the interior areas with loose particles. The tool is driven by an electric drill and is connected to a vacuum source that removes debris resulting from the cleaning and polishing action.

Headley, C. A.↗

French wind generator systems

The experimental design of a wind driven generator with a rated power of 800 kilovolt amperes and capable of being connected to the main electrical network is reported. The rotor is a three bladed propeller; each blade is twisted but the fixed pitch is adjustable. The asynchronous 800-kilovolt ampere generator is driven by the propeller through a gearbox. A dissipating resistor regulates the machine under no-load conditions. The first propeller on the machine lasted 18 months; replacement of the rigid propeller with a flexible structure resulted in breakdown due to flutter effects.

Noel, J. M.↗

Molecular effect on equilibrium charge-state distributions

The paper describes an experiment consisting of the acceleration of N(+) and N2(+) ions to energies between 0.25 and 1.75 MeV and their injection through a thin carbon foil, whereupon they were charge-state analyzed with an electrostatic analyzer. A foil-covered electrically suppressed Faraday cup, connected to a stepping motor, moved in the plane of the dispersed beams. The Faraday cup current, which was proportional to the number of incident ions, was sent to a current digitizer and computer programmed as a multiscaler. The energy-dependent charge-state fractions, the mean charge and the distribution width were calculated. It was shown that for incident atoms, the charge state distribution appeared to be spread over more charge states, while for the incident molecules, there was a greater fraction of charge states near the mean charge.

Wickholm, D.↗