Search NASA⌕ Search

SEARCH · Search NASA

Results for “electron source”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Atomic fluctuations in electronic materials revealed by dephasing

The microscopic origin and timescale of the fluctuations of the energies of electronic states has a significant impact on the properties of interest of electronic materials, with implication in fields ranging from photovoltaic devices to quantum information processing. Spectroscopic investigations of coherent dynamics provide a direct measurement of electronic fluctuations. Modern multidimensional spectroscopy techniques allow the mapping of coherent processes along multiple time or frequency axes and thus allow unprecedented discrimination between different sources of electronic dephasing. Exploiting modern abilities in coherence mapping in both amplitude and phase, we unravel dissipative processes of electronic coherences in the model system of CdSe quantum dots (QDs). The method allows the assignment of the nature of the observed coherence as vibrational or electronic. The expected coherence maps are obtained for the coherent longitudinal optical (LO) phonon, which serves as an internal standard and confirms the sensitivity of the technique. Fast dephasing is observed between the first two exciton states, despite their shared electron state and common environment. This result is contrary to predictions of the standard effective mass model for these materials, in which the exciton levels are strongly correlated through a common size dependence. In contrast, the experiment is in agreement with ab initio molecular dynamics of a single QD. Electronic dephasing in these materials is thus dominated by the realistic electronic structure arising from fluctuations at the atomic level rather than static size distribution. The analysis of electronic dephasing thereby uniquely enables the study of electronic fluctuations in complex materials.

36 MATERIALS SCIENCE↗

Outer heliospheric radio emissions. I - Constraints on emission processes and the source region

Observations by Voyager 1 and 2 of LF radio emissions near 2 and 3 kHz during the interval 1983-1987 while at heliocentric distances from 15 to 27 AU and 11 to 20 AU, respectively, are reported. Constraints on the emission processes and source characteristics are discussed. Minimum Langmuir wave electric fields in the source region, based solely on the kinematics of the radiation processes, lie in the range 1-100 micro-V/m for nominal source and electron beam parameters. Path lengths for fundamental and harmonic emission processes are calculated. The observed levels of radiation can be produced in path lengths and source dimensions smaller than 1 AU provided the participating Langmuir waves have effective temperatures of about 10 exp 17 K. Previous source models for the radiation are discussed.

Cairns, Iver H.↗

Drift-Resonant Interaction of Magnetospheric Relativistic Electrons with Ultra-Low Frequency (ULF) Waves: Comparison between Observations and Simulations

By analyzing CRRES and GOES observations on Aug. 27 1991, Tan et al. [2004] reported evidence of magnetospheric relativistic electron acceleration by resonant interactions with PC5 ULF waves. The event showed strong ULF wave activities after a storm sudden commencement (SSC) and energetic electron fluxes were enhanced in 2 hours. The electron flux peak observed in energy channels (0.6 - 1.1 MeV) were modulated by local electric field observed by CRRES. In this study, we set up a drift-resonant interaction model between ULF wave and magnetospheric relativistic electrons to model the observed electron flux in the event. In this model, the poloidal mode wave is concentrated in the dayside and the toroidal mode wave is concentrated in two flanks. The toroidal mode waves in the dawn and dusk flanks are in anti-phase. We found that electron can be accelerated jointly by the poloidal wave in the dayside and toroidal wave in flanks. The dayside poloidal wave serves as the dominant source of electron acceleration. The simulated electron flux variations agree well with observations both in fine details and long period behavior. These agreements in electron behavior indicate that the ULF wave plays an important role in accelerating MeV relativistic electrons around the geosynchronous orbit.

Fung, Shing↗

Pump–probe experimental methodology at the Linac Coherent Light Source

Experimental methods that use free-electron laser (FEL) sources that can deliver short X-ray pulses below a 10 fs pulse duration and traditional optical lasers are ideal tools for pump–probe experiments. However, these new methods also come with a unique set of challenges, such as how to accurately determine temporal overlap between two sources at the femtosecond scale and how to correct for the pulse-to-pulse beam property fluctuations of the FEL light derived from the self-amplified spontaneous emission process. Over the past several years of performing pump–probe experiments at the Linac Coherent Light Source (LCLS), new methods and tools have been developed to improve the ways experimental timing is measured, monitored and scanned. The aim of this article is to present an overview of the most commonly used techniques at LCLS to perform pump–probe-type experiments.

47 OTHER INSTRUMENTATION↗

Locally Resolved Electron Emission Area and Unified View of Field Emission from Ultrananocrystalline Diamond Films

One of the common problems in case of field emission from polycrystalline diamond films, which typically have uniform surface morphology, is uncertainty in determining exact location of electron emission sites across the surface. Although several studies have suggested that grain boundaries are the main electron emission source, it is not particularly clear what makes some sites emit more than the others. It is also practically unclear how one could quantify the actual electron emission area and therefore field emission current per unit area. In this paper we study the effect of actual, locally resolved, field emission (FE) area on electron emission characteristics of uniform planar highly conductive nitrogen-incorporated ultrananocrystalline diamond ((N)UNCD) field emitters. It was routinely found that field emission from as-grown planar (N)UNCD films is always confined to a counted number of discrete emitting centers across the surface which varied in size and electron emissivity. It was established that the actual FE area critically depends on the applied electric field, as well as that the actual FE area and the overall electron emissivity improve with sp2 fraction present in the film irrespectively of the original substrate roughness and morphology. To quantify the actual FE area and its dependence on the applied electric field, imaging experiments were carried out in a vacuum system in a parallel-plate configuration with a specialty anode phosphor screen. Electron emission micrographs were taken concurrently with I-V characteristics measurements. In addition, a novel automated image processing algorithm was developed to process extensive imaging datasets and calculate emission area per image. By doing so, it was determined that the emitting area was always significantly smaller than the FE cathode surface area. Namely, the actual FE area would change from 5×10-3 % to 1.5 % of the total cathode area with the applied electric field increased. Finally and most importantly, it was shown that when I-E curves as measured in the experiment were normalized by the field-dependent emission area, the resulting j-E curves demonstrated a strong kink and significant deviation from Fowler-Nordheim (FN) law, and eventually saturated at a current density of ~100 mA/cm2 . This value was nearly identical for all (N)UNCD films measured in this study, regardless of the substrate.

36 MATERIALS SCIENCE↗

Electron precipitation zones around major ground-based VLF signal sources

The spatial distribution of electron precipitation induced by VLF signals from ground-based transmitters is determined by using a test particle computer model of the gyroresonant wave-particle interaction (Inan et al., 1982). The results are presented as contours of energy flux on a map of the region around each transmitter. It is shown that the size of the precipitation zones is a strong function of the geographic location of the transmitter, as well as its radiated power and operating frequency. In general, the precipitation zones are much wider in longitude than in latitude and are oriented along lines of constant geomagnetic latitude. Assuming backscatter and/or wave echoing, precipitation zones around the points that are magnetically conjugate to the sources are also estimated. The results presented can be used to interpret satellite- or ground-based measurements of the precipitation induced by ground-based VLF transmitters.

Inan, U. S.↗

High-viscosity injector-based pink-beam serial crystallography of microcrystals at a synchrotron radiation source

Since the first successful serial crystallography (SX) experiment at a synchrotron radiation source, the popularity of this approach has continued to grow showing that third-generation synchrotrons can be viable alternatives to scarce X-ray free-electron laser sources. Synchrotron radiation flux may be increased ∼100 times by a moderate increase in the bandwidth (`pink beam' conditions) at some cost to data analysis complexity. Here, we report the first high-viscosity injector-based pink-beam SX experiments. The structures of proteinase K (PK) and A 2A adenosine receptor (A 2A AR) were determined to resolutions of 1.8 and 4.2 Å using 4 and 24 consecutive 100 ps X-ray pulse exposures, respectively. Strong PK data were processed using existing Laue approaches, while weaker A 2A AR data required an alternative data-processing strategy. This demonstration of the feasibility presents new opportunities for time-resolved experiments with microcrystals to study structural changes in real time at pink-beam synchrotron beamlines worldwide.

36 MATERIALS SCIENCE↗

Review of High Intensity Ion Source Development and Operation

The Electron Cyclotron Resonance Ion Source (ECRIS) has transformed the nuclear physics research field over the last 47 years. Today, the performance of ion sources is the first parameter that defines the design performance of existing facilities as well as the design approach and performance of new facilities. In this paper, I will review the current "state of the art" performance capabilities for ECRISs as well as other ion sources and how those current capabilities form the primary design criteria for new nuclear physics facilities and set the limiting performance for existing facilities. I will close with a short-term look into the future for these ion sources and other competing types.

Pardo, Richard↗

Shell-Based Support Structure for the 45 GHz ECR Ion Source MARS-D

Superconducting electron cyclotron resonance ion sources (ECRISs) using NbTi coils and optimized for 28 GHz resonant heating have been successfully operated for almost two decades. Moving to higher heating frequencies requires increased magnetic fields, but traditional racetrack-and-solenoid ECRIS structures are at their limit using NbTi. Rather than moving to a superconductor untested in this field, we report the Mixed Axial and Radial field System (MARS) being developed at Lawrence Berkeley National Laboratory employs a novel closed-loop-coil design that more efficiently utilizes conductor fields and will allow the use of NbTi in a next-generation, 45 GHz ECRIS. This article presents the design of the shell-based support structure central to the MARS-D magnet design, as well as structural analysis of its components and optimization of pre-load parameters that will guarantee its successful operation.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Free electron lasers driven by linear induction accelerators: High power radiation sources

The technology of Free Electron Lasers (FELs) and linear induction accelerators (LIAs) is addressed by outlining the following topics: fundamentals of FELs; basic concepts of linear induction accelerators; the Electron Laser Facility (a microwave FEL); PALADIN (an infrared FEL); magnetic switching; IMP; and future directions (relativistic klystrons). This presentation is represented by viewgraphs only.

Orzechowski, T. J.↗

The propagation of Jovian electrons to earth

An analysis of the Jovian electron flux increases observed by the earth-orbiting satellite Imp 8 throughout five 13 month Jovian synodic years during the period from launch of the satellite in 1973 to 1979 is presented. The analysis defines the characteristics of Jovian propagation to earth. Corotating interaction regions (CIR) that form at the leading edges of fast solar wind streams continue to modulate the propagation of MeV electrons from Jupiter to the orbit of the earth to produce approximately 27 day recurrent variations in the Jovian electron density. The new and significant result of this study is that these time-intensity profiles are more accurately described not by assumption that Jupiter is a constant source of electrons, but rather by assuming that electron emission is initiated with each passage of CIR by Jupiter with the emission continuing for only several days.

Chenette, D. L.↗

Source variations of interplanetary Jovian electrons - Voyagers 1 and 2 results

The large intensity of interplanetary Jovian electrons at 1 AU and near the Jovian magnetosphere have been attributed to the large scale solar wind structure. The only variations that can be definitely attributed to the source (i.e. the magnetosphere) are the 10 hour variations observed within about 1 AU of Jupiter. During the pre-Jupiter-encounter period, the Voyagers 1 and 2 spacecraft are separated by about 1 corotation day, facilitating the separation of variations due to corotating streams, which occur 1 day apart on the two spacecraft

Conlon, T. F.↗

High Energy Cosmic Electrons: Messengers from Nearby Cosmic Ray Sources or Dark Matter?

This slide presentation reviews the recent discoveries by the Large Area Telescope (LAT) and the Gamma-ray Burst Monitor (GBM) on board the Fermi Gamma-Ray Telescope in reference to high energy cosmic electrons, and whether their source is cosmic rays or dark matter. Specific interest is devoted to Cosmic Ray electrons anisotropy,

Moiseev, Alexander↗

Imaginary admittance and charge transfer resistance correlate to the physiological status of Shewanella oneidensis cultures in real time

Monitoring microbial activity is essential for industrial and environmental applications to proceed efficiently. To minimize time and labor-intensive monitoring, a new paradigm is required for in-situ, real time analysis. Since bioconversion of organics is accomplished by microorganisms through the oxidation of feedstocks linked to the reduction of electron acceptors, microorganisms can be viewed as electrochemical catalysts. In this respect, cell membranes have an electrical potential, which is analogous to a conventional capacitor and linked dynamically to cellular activity. Here, in this study, we demonstrate the use of electrochemical impedance spectrometry (EIS) and cyclic voltammetry (CV) for monitoring microbial metabolic activity in real time, in-situ. The effect of organic electron donors as a function of concentration to the physiological status of strains of Shewanella oneidensis was determined. In this study, the pyomelanin overproducer (S. oneidensis ΔhmgA) and the pyomelanin deficient mutant (S. oneidensis ΔmelA) were chosen due to different surface electrochemical characteristics along with differences in oxygen utilization efficiency. CV, relative admittance, phase shift and permittivity changed with growth status and correlated with electron flow from organic carbon sources and terminal electron acceptor availability. This work offers a novel and inexpensive approach to real time monitoring with the advantage of abundant data.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High precision real-time insertion device and monochromator synchronization at NSLS-II

We report that insertion devices have become the dominant photon source at synchrotron and free electron laser light source facilities the world over. Undulators, characterized by their small deflection parameter, exhibit a high degree of constructive interference in photon production from high energy charged particle beams leading to very high photon rates at specific harmonics of the fundamental frequency with relatively narrow spectral widths. Spectroscopic measurements of interest typically span several of these harmonic widths, which requires precision adjustment of an undulator’s magnetic gap to maintain peak flux within the much narrower bandwidth of a beamline monochromator at the desired energy. High precision insertion device controls are developed at NSLS-II including real-time linked control of monochromator hardware allowing for fast, high precision, hardware triggered, spectroscopic measurements. Furthermore, this fast fly scan method is described, compared statistically for self consistency, and shown to be far superior in both efficiency and accuracy as compared to standard step scan measurements.

36 MATERIALS SCIENCE↗

A possible energy source to power stable auroral red arcs - Precipitating electrons

Results of coincident measurements by ground-based photometers and the low-altitude plasma instrument on board the Dynamics Explorer 2 satellite are presented that demonstrate the association of precipitating low-energy electrons with stable auroral red (SAR) arcs. A search of available data has yielded 23 instances of DE 2 overflights during the presence of SAR arcs being monitored by the photometers. For each case, downward fluxes of electrons are found to be enhanced along field lines penetrating the arcs in relation to regions both north and south of the features. Modeling of the atmospheric response to these influxes indicates that these electrons can represent a major source of the energy required to establish temperature profiles within the ionospheric electron gas that are sufficient to produce the recorded 6300-A emission rates. The sensitivity of these results to uncertainties of the assumed spacecraft potential and thermospheric composition has been investigated and found to be important, but does not alter the conclusion that precipitating electrons are a fundamental link in the production of SAR arcs.

Slater, D. W.↗

The Wind and Temperature Spectrometer (WTS) in the Atmospheric Neutral Density Experiment (ANDE) Satellite

Miniaturization efforts in new spectrometers for ionosphere/thermosphere investigations of the ion-drifts and neutral winds and corresponding temperatures make possible very light (about 250 g) packages consuming less than 0.4 W. Previously described, our approach measures the angular and energy distributions of neutral atoms and molecules (or ions) in two perpendicular planes; using those distributions to determine the full wind vector, the temperature and the relative densities of O and N2, as required for the ANDE mission. The measurements require two separate electron impact ion sources each with its own electron beam cathode. We have developed a low-temperature thermionic emission cathode that delivers 1 mA electron current at 80 mW power, making it possible to operate neutral wind-temperature experiments for the first time with powers less than 0.5 W. Advances in the ion optics of the energy-angle spectrometer enhance the energy resolution-aperture product more than a factor of 3 to enable energy resolutions of a few percent with large apertures. With these technology improvements it is now possible to obtain the full neutral wind vector, temperature and O/N2, density ratio once per second in a 250g/0.4W package with sensitivity up to about 500 km altitude in the thermosphere. We will describe the WTS as deployed in ANDE and show simulated data with the non-linear least squares analysis to illustrate expected performance of the WTS in the estimated errors in the three components of the wind, the temperature, and the relative densities.

Herrero, F. A.↗

Transport modeling of convection dominated helicon discharges in Proto-MPEX with the B2.5-Eirene code

Data-constrained interpretative analyses of plasma transport in convection dominated helicon discharges in the Proto-MPEX linear device, and predictive calculations with additional Electron Cyclotron Heating/Electron Bernstein Wave (ECH/EBW) heating, are reported. The B2.5-Eirene code, in which the multi-fluid plasma code B2.5 is coupled to the kinetic Monte Carlo neutrals code Eirene, is used to fit double Langmuir probe measurements and fast camera data in front of a stainless-steel target. The absorbed helicon and ECH power (11 kW) and spatially constant anomalous transport coefficients that are deduced from fitting of the probe and optical data are additionally used for predictive simulations of complete axial distributions of the densities, temperatures, plasma flow velocities, particle and energy fluxes, and possible effects of alternate fueling and pumping scenarios. The somewhat hollow electron density and temperature radial profiles from the probe data suggest that Trivelpiece-Gould wave absorption is the dominant helicon electron heating source in the discharges analyzed here. There is no external ion heating, but the corresponding calculated ion temperature radial profile is not hollow. Rather it reflects ion heating by the electron-ion equilibration terms in the energy balance equations and ion radial transport resulting from the hollow density profile. With the absorbed power and the transport model deduced from fitting the sheath limited discharge data, calculated conduction limited higher recycling conditions were produced by reducing the pumping and increasing the gas fueling rate, resulting in an approximate doubling of the target ion flux and reduction of the target heat flux.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗