Search NASA⌕ Search

SEARCH · Search NASA

Results for “error quantification”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

SU-E-T-792: Validation of a Secondary TPS for IROC-H Recalculation of Anthropomorphic Phantoms

Purpose: To validate a secondary treatment planning system (sTPS) for use by the Imaging & Radiation Oncology Core-Houston (IROC-H). The TPS will recalculate phantom irradiations submitted by institutions to IROC-H and compare plan results of the institution to the sTPS. Methods: In-field dosimetric data was collected by IROC-H for numerous linacs at 6, 10, 15, and 18 MV. The data was aggregated and used to define reference linac classes; each class was then modeled in the sTPS (Mobius3D) by matching the in-field characteristics. Fields used to collect IROC-H data were recreated and recalculated using Mobius3D. The same dosimetric points were measured in the recalculation and compared to the initial collection data. Additionally, a 6MV Monte Carlo beam configuration was used to compare penumbrae in the Mobius3D models. Finally, a handful of IROC-H head and neck phantoms were recalculated using Mobius3D. Results: Recalculation and quantification of differences between reference data and Mobius3D values resulted in a relative matching score of 12.45 (0 is a perfect match) for the default 6MV Mobius3D beam configuration. By adjusting beam configuration options, iterations resulted in scores of 8.45, 6.32, and 3.52, showing that customization could have a dramatic effect on beam configuration. After in-field optimization, penumbra was compared between Monte Carlo and Mobius3D for the reference fields. For open jaw fields, FWHM field widths and penumbra widths were different by <0.6 and <1mm respectively; for MLC open fields the penumbra widths were up to 1.5mm different. Phantom recalculations showed good agreement, having an average of 0.6% error per beam. Conclusion: A secondary TPS has been validated for simple irradiation geometries using reference data collected by IROC-H. The beam was customized to the reference data iteratively and resulted in a good match. This system can provide independent recalculation of phantom plans based on independent reference data.

60 APPLIED LIFE SCIENCES↗

Adaptive Bayesian Inference for Prediction

Performing rigorous predictive simulation necessitates that all available data be incorporated into the modeling process in order to accurately quantify uncertainties in predictions of the model. Statistical Bayesian inference is the most commonly used approach for incorporating data into uncertainty estimates. Statistical Bayesian inference uses data and an assumed error model to inform posterior distributions of model input variables and model discrepancies. An explicit characterization of the posterior distribution is not formed, but rather methods such as Markov chain Monte-Carlo (MCMC) are used to draw samples from the posterior. These samples are then used to evaluate statistics, such as integrals, of predicted quantities of interest (QoI). Recently the authors have developed an alternative reformulation of Bayesian inference based upon a measure-theoretic inversion technique. Unlike traditional statistical Bayesian inference, this reformulation allows us to directly interrogate the posterior distribution and, consequently, to generate samples from the posterior without MCMC. In this work we use forward propagation uncertainty quantification techniques to reduce the cost of approximating the posterior distribution. Specifically we investigate goal-oriented adaptive sparse grid approximation methods. These adaptive methods concentrate high-fidelity model evaluations in regions of the parameter space that both significantly contribute to the uncertainty in specified QoI and are informed by the available data. Numerical results are presented to compare our approach with the standard statistical Bayesian approach and to demonstrate the effectiveness of the goal-oriented adaptivity.

97 MATHEMATICS AND COMPUTING↗

Application of quantitative methods for reliability testing of a nuclear power plant digital rod position indication diagnostic system - 391

Obsolescence, aging, reliability, and performance issues are driving nuclear facilities to replace conventional analog Instrumentation and Control (I and C) systems with digital technologies. In addition, the designs of the next generation of nuclear reactors, including Small Modular Reactors (SMRs), will incorporate digital I and C for most, if not all, of their safety and non-safety related functions. As part of an on-going research and development (R and D) effort under the auspices of the U.S. Department of Energy (DOE), Analysis and Measurement Services Corporation (AMS) is developing a platform to provide automated testing of digital I and C systems and create a standard method of evaluation for reliability assessments. This hands-on R and D effort has produced a Software Reliability Tester (SRT), which is a set of software and hardware tools designed to automate the testing of digital I and C systems to measure and quantify how well the systems perform under normal operating conditions and in the presence of faults. Furthermore, the SRT provides the foundation for a practical tool to automate verification and validation (V and V) activities and reduce the amount of testing time of digital I and C systems. When combined with its capabilities of integrating both reliability and fault tolerance quantification, the SRT can be used to ensure that digital I and C implementations are both safe and cost-effective for the nuclear industry. This paper describes the application of the SRT to perform V and V of a new Digital Rod Position Indication (DRPI) diagnostic system. The DRPI diagnostic system is a digital system that monitors the rod address and rod position data bus voltages of typical DRPI systems in nuclear power plants to detect and diagnose faults. For this application, the SRT was configured to exercise the inputs of the DRPI diagnostic system, and test cases were generated for common system faults such as address and data bit errors, bus voltage, and timing problems. These test cases were applied by the SRT hardware as voltage inputs to the DRPI diagnostic system and the outputs were compared to expected values generated by a model of the DRPI diagnostic system. Included in the paper is a description of the overall design of the SRT including the hardware and software architectures. Methodologies for automating test cases are also described. V and V using the SRT demonstrates the benefits of automated testing and qualification to provide a quantitative assessment of reliability and cost effective implementation of digital I and C in existing and next generation nuclear power plants. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Maximum Likelihood Spectrum Decomposition for Isotope Identification and Quantification

A spectral decomposition method has been implemented to identify and quantify isotopic source terms in high-resolution gamma-ray spectroscopy in static geometry and shielding scenarios. Monte Carlo simulations were used to build the response matrix of a shielded high-purity germanium detector monitoring an effluent stream with a Marinelli configuration. The decomposition technique was applied to a series of calibration spectra taken with the detector using a multi-nuclide standard. These results are compared with decay-corrected values from the calibration certificate. For most nuclei in the standard ( 241 Am, 109 Cd, 137 Cs, and 60 Co), the deviations from the certificate values were generally no more than 6% with a few outliers as high as 10%. Furthermore, for 57 Co, the radionuclide with the lowest activity, the deviations from the standard reached as high as 25%, driven by the meager statistics in the calibration spectra. In addition, a complete treatment of error propagation for the technique is presented.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Three-dimensional liver motion tracking using real-time two-dimensional MRI

Purpose: Combined magnetic resonance imaging (MRI) systems and linear accelerators for radiotherapy (MR-Linacs) are currently under development. MRI is noninvasive and nonionizing and can produce images with high soft tissue contrast. However, new tracking methods are required to obtain fast real-time spatial target localization. This study develops and evaluates a method for tracking three-dimensional (3D) respiratory liver motion in two-dimensional (2D) real-time MRI image series with high temporal and spatial resolution. Methods: The proposed method for 3D tracking in 2D real-time MRI series has three steps: (1) Recording of a 3D MRI scan and selection of a blood vessel (or tumor) structure to be tracked in subsequent 2D MRI series. (2) Generation of a library of 2D image templates oriented parallel to the 2D MRI image series by reslicing and resampling the 3D MRI scan. (3) 3D tracking of the selected structure in each real-time 2D image by finding the template and template position that yield the highest normalized cross correlation coefficient with the image. Since the tracked structure has a known 3D position relative to each template, the selection and 2D localization of a specific template translates into quantification of both the through-plane and in-plane position of the structure. As a proof of principle, 3D tracking of liver blood vessel structures was performed in five healthy volunteers in two 5.4 Hz axial, sagittal, and coronal real-time 2D MRI series of 30 s duration. In each 2D MRI series, the 3D localization was carried out twice, using nonoverlapping template libraries, which resulted in a total of 12 estimated 3D trajectories per volunteer. Validation tests carried out to support the tracking algorithm included quantification of the breathing induced 3D liver motion and liver motion directionality for the volunteers, and comparison of 2D MRI estimated positions of a structure in a watermelon with the actual positions. Results: Axial, sagittal, and coronal 2D MRI series yielded 3D respiratory motion curves for all volunteers. The motion directionality and amplitude were very similar when measured directly as in-plane motion or estimated indirectly as through-plane motion. The mean peak-to-peak breathing amplitude was 1.6 mm (left-right), 11.0 mm (craniocaudal), and 2.5 mm (anterior-posterior). The position of the watermelon structure was estimated in 2D MRI images with a root-mean-square error of 0.52 mm (in-plane) and 0.87 mm (through-plane). Conclusions: A method for 3D tracking in 2D MRI series was developed and demonstrated for liver tracking in volunteers. The method would allow real-time 3D localization with integrated MR-Linac systems.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluating Probabilistic Deep Learning Methods for Uncertainty Quantification of Precipitation Bias Correction

Climate models often exhibit biases in their precipitation predictions, particularly underestimating high-intensity events and overestimating low precipitation. Deep learning approaches offer promising solutions, but their epistemic uncertainty associated with a deep learning–based bias correction method has not previously been quantified for reliable downstream climate impact studies. While methods for capturing the epistemic uncertainty in deep learning frameworks exist, there is currently no consensus on the best method. In this work, we compare three uncertainty quantification (UQ) methods—Deep Ensembles (DEns), Monte Carlo Dropout (MCD), and Flipout—by assessing the reliability of their uncertainty estimates using standard measures such as sharpness and calibration. These UQ methods are applied to an existing deep learning precipitation bias correction model known as UFNet: a coupled U-Net and fully connected neural network. The methods utilized to assess the models’ uncertainties are 1) calibration, which ensures that the expected probabilities of the model align with reality and 2) sharpness, which is a measure of the precision of the model’s probabilistic predictions. Of the three UQ methods evaluated, the DEns and MCD methods demonstrated the best-calibrated performance (expected calibration error of 0.36 and 0.35, respectively), compared to Flipout (0.58). In contrast, Flipout had the sharpest predictions and the highest metric performance in bias correcting precipitation—especially for higher-order moments such as kurtosis with a spatial correlation of 72% compared to 32% and 55% spatial correlation for DEns and MCD, respectively. Of the three UQ methods, MCD was found to be the most suitable method for UQ purposes based on its calibration, sharpness, and computational requirements.

Bayesian methods↗

Regulatory Decision-Making Process Using 'Weight of Evidence: An Evidence Integration Approach' by the State of Washington at the Hanford Site - 20163

Performance Assessment and Environmental Impact Statement Modeling, Human and Ecological Risk Assessments are the tools used by the Washington State Department of Ecology (Ecology) to make regulatory decisions for permitting and cleanup. These efforts all inherently have large amounts of uncertainty no matter how many alternative approaches are attempted. Professional feedback from tribal governments, stakeholders, federal and state regulators, the public and independent peer review groups are taken into account in this process of informed decision making. The process also includes full evaluation of the comments and the associated reviews made by the various peer review groups such as the Low -Level Waste Disposal Facility Federal Review Group (DOE order 435.1) and the Nuclear Regulatory Commission (NRC). The evolution of technology has produced quicker and more efficient fate and transport modeling tools with related quantification of uncertainties and their significance. Groundwater and vadose zone models have been expanded across the entire Hanford site. Many of the technical approaches identified in the Washington State Regulations are updated using current knowledge to better understand the complexities of the Hanford Site using the latest state of the art tools for risk assessment and modeling. More emphasis and time are directed on defining uncertainty and then managing the uncertainty. One added tool is to run sensitivity cases based on informed decision making. The weight of evidence approach considers all relevant information in an integrative assessment that takes into account the kinds of evidence available, the quality and quantity, the uncertainty and error associated with each type, and how they fit together. Evidence of integration involves looking at systematic reviews and evaluating their strengths and weaknesses. In conclusion, Ecology, Washington State's lead regulatory agency at the Hanford site, has had to modify its site closure approach compared to the rest of the state. A more holistic approach dealing with the Hanford site as an integrated system has evolved leading to a defensible informed approach for regulatory closure decisions. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Quantification of Physical and Numerical Mixing in a Coastal Ocean Model Using Salinity Variance Budgets

Numerical mixing, the spurious mixing primarily generated by the discretization of advection, is often significant in estuarine and coastal models due to sharp, energetic fronts. In this study, we compare on- and offline estimates of numerical mixing in a submesoscale-resolving realistic simulation of the ocean state over the Texas-Louisiana continental shelf. While offline estimates of numerical mixing differ from online estimates, offline methods may be the only analysis available. This study offers insight into the differences between the on- and offline methods. We use two methods to estimate numerical mixing offline, based on salinity squared $s^2$ and volume-mean salinity variance $s^{\prime^2}$. Numerical mixing estimated from the $s^{\prime^2}$ budget is generally within 60\% of the magnitude for the online method but captures the temporal variability well. However, the $s^2$ budget compares poorly due to larger truncation errors associated with the tendency and advection terms, which can be reduced by increasing the model output frequency. We also investigate the effects of horizontal resolution on numerical mixing using a two-way nested grid. The volume-integrated numerical mixing constitutes 57\% of the bulk physical mixing -- the mixing prescribed by the turbulence closure scheme -- in the coarse model and may exceed the physical mixing by half an order of magnitude. We find that numerical mixing is reduced by 35\% on average in the nested model, less than expected based on scaling of the numerical mixing for an upwind advection scheme, likely due to new dynamical processes that emerge in the nested simulation.

54 ENVIRONMENTAL SCIENCES↗

A probability density function model describing height estimation uncertainty due to image pixel intensity noise in digital fringe projection measurements

Digital fringe projection is a surface-profiling technique used for highly accurate non-contact measurements. As with any measurement technique, a variety of sources degrade to the measurement accuracy of the method. Here, this paper presents an analytically-derived probability density function that explicitly models the surface height measurement error due to inevitable phase measurement error, and it includes the specific case of pixel noise inducing the phase measurement error that ultimately leads to the height estimation error. The accuracy of the model was validated through Monte-Carlo simulations of resultant height distributions subject to arbitrarily correlated pixel intensity noise and experimental digital fringe projection measurements where the pixel-by-pixel height uncertainty estimations were compared to the predictions of the derived model.

42 ENGINEERING↗

Improving the trust in results of numerical simulations and scientific data analytics

This white paper investigates several key aspects of the trust that a user can give to the results of numerical simulations and scientific data analytics. In this document, the notion of trust is related to the integrity of numerical simulations and data analytics applications. This white paper complements the DOE ASCR report on Cybersecurity for Scientific Computing Integrity by (1) exploring the sources of trust loss; (2) reviewing the definitions of trust in several areas; (3) providing numerous cases of result alteration, some of them leading to catastrophic failures; (4) examining the current notion of trust in numerical simulation and scientific data analytics; (5) providing a gap analysis; and (6) suggesting two important research directions and their respective research topics. To simplify the presentation without loss of generality, we consider that trust in results can be lost (or the results’ integrity impaired) because of any form of corruption happening during the execution of the numerical simulation or the data analytics application. In general, the sources of such corruption are threefold: errors, bugs, and attacks. Current applications are already using techniques to deal with different types of corruption. However, not all potential corruptions are covered by these techniques. We firmly believe that the current level of trust that a user has in the results is at least partially founded on ignorance of this issue or the hope that no undetected corruptions will occur during the execution. This white paper explores the notion of trust and suggests recommendations for developing a more scientifically grounded notion of trust in numerical simulation and scientific data analytics. We first formulate the problem and show that it goes beyond previous questions regarding the quality of results such as V&V, uncertainly quantification, and data assimilation. We then explore the complexity of this difficult problem, and we sketch complementary general approaches to address it. This paper does not focus on the trust that the execution will actually complete. The product of simulation or of data analytic executions is the final element of a potentially long chain of transformations, where each stage has the potential to introduce harmful corruptions. These corruptions may produce results that deviate from the user-expected accuracy without notifying the user of this deviation. There are many potential sources of corruption before and during the execution; consequently, in this white paper we do not focus on the protection of the end result after the execution.

97 MATHEMATICS AND COMPUTING↗

Structural analysis of cortical porosity applied to HR-pQCT data

Purpose: The investigation of cortical porosity is an important aspect of understanding biological, pathoetiological, and biomechanical processes occurring within the skeleton. With the emergence of HR-pQCT as a noninvasive tool suitable for clinical use, cortical porosity at appendicular sites can be directly visualizedin vivo. The aim of this study was to introduce a novel topological analysis of the cortical pore network for HR-pQCT data and determine the influence of resolution on measures of cortical pore network microstructure and topology. Methods: Cadaveric radii were scanned using HR-pQCT at two different voxel sizes (41 and 82μm) and also using μCT at a voxel size of 18 μm. HR-pQCT and μCT image sets were spatially coregistered. Segmentation and quantification of cortical porosity (Ct.Po) and mean pore diameter (Ct.Po.Dm) were achieved using an established extended cortical analysis technique. Topological classification of individual pores was performed using topology-preserving skeletonization and multicolor dilation algorithms. Based on the pore skeleton topological classification, the following parameters were quantified: total number of planar surface-skeleton canals (N.Slabs), tubular curve-skeleton canals (N.Tubes), and junction elements (N.Junctions), mean slab volume (Slab.Vol), mean tube volume (Tube.Vol), mean slab orientation (Slab.θ), mean tube orientation (Tube.θ), N.Slabs/N.Tubes, and integral (total) slab volume/integral tube volume (iSlab.Vol/iTube.Vol). An in vivo reproducibility study was also conducted to assess short-term precision of the topology parameters. Precision error was characterized using root mean square coefficient of variation (RMSCV%). Results: Correlations toμCT values for Ct.Po were significant for both the 41 and 82 μm HR-pQCT data (41: r{sup 2} = 0.82, p < 0.001, 82: r{sup 2} = 0.75, p < 0.001). For Ct.Po.Dm, only the 41 μm data were significantly predictive of μCT values (r{sup 2} = 0.72, p < 0.01) Data at both HR-pQCT voxel sizes were strongly predictive of the μCT values for N.Slabs (41: r{sup 2} = 0.93, p < 0.001; 82: r{sup 2} = 0.84, p < 0.001), N.Tubes (41: r{sup 2} = 0.94, p < 0.001; 82: r{sup 2} = 0.84, p < 0.001), and N.Junctions (41: r{sup 2} = 0.93, p < 0.001; 82: r{sup 2} = 0.78, p < 0.001), though proportional bias was evident in these correlations. Weak correlations were seen for iSlab.Vol/iTube.Vol at both voxel sizes (41: r{sup 2} = 0.52, p < 0.01; 82: r{sup 2} = 0.39, p < 0.05). Slab.Vol was significantly correlated to μCT data at 41 μm (r{sup 2} = 0.60, p < 0.01) but not at 82 μm, while Tube.Vol was significantly correlated at both voxel sizes (41: r{sup 2} = 0.79, p < 0.001; 82: r{sup 2} = 0.68, p < 0.01). In vivo precision error for these parameters ranged from 2.31 to 9.68 RMSCV%. Conclusions: Strong correlations betweenμCT- and HR-pQCT-derived measurements were found, particularly in HR-pQCT images obtained at 41 μm. These data are in agreement with our previous study investigating the effect of voxel size on standard HR-pQCT metrics of trabecular and cortical microstructure, and extend our previous findings to include topological descriptors of the cortical pore network.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

FAIR Data and Interpretable AI Framework for Architectured Metamaterials (Final Report)

This research program established a transformative framework for the discovery and design of mechanical metamaterials, which are architected structures engineered to control physical phenomena like sound and vibration in ways natural materials cannot. To overcome the traditional reliance on trial-and-error, the project developed an interpretable Artificial Intelligence (AI) framework that moves beyond "black box" models to reveal the specific geometric patterns—such as "unit-cell templates"—that govern a material’s performance. A major breakthrough was the development of a hierarchical design method, which allows a single material to block vibrations across multiple frequency ranges simultaneously by layering patterns at different scales without them interfering with one another. This was further expanded to include irregular, graph-based designs that use spanning tree algorithms to ensure structural connectivity while allowing for customized, direction-dependent properties like stiffness and acoustic impedance. Beyond design, the project addressed the practicalities of real-world production by developing uncertainty quantification techniques that account for manufacturing defects and material variability, reducing the need for expensive physical testing by orders of magnitude. To speed up the discovery process, the team implemented Gaussian Process Regression and other surrogate models that provide accurate performance predictions at a fraction of the traditional computational cost. The AI-generated designs were successfully validated through fabrication of physical samples and wave propagation experiments, confirming their ability to accurately guide or reflect waves as predicted. By contributing these tools and high-quality FAIR benchmark datasets to the wider scientific community, this work provides a scalable foundation for advancing technologies in aerospace vibration control, medical imaging, and noise reduction.

36 MATERIALS SCIENCE↗

Hierarchical Modeling to Enhance Spectrophotometry Measurements—Overcoming Dynamic Range Limitations for Remote Monitoring of Neptunium

A robust hierarchical model has been demonstrated for monitoring a wide range of neptunium concentrations (0.75–890 mM) and varying temperatures (10–80 °C) using chemometrics and feature selection. The visible–near infrared electronic absorption spectrum (400–1700 nm) of monocharged neptunyl dioxocation (Np(V) = NpO2+) includes many bands, which have molar absorption coefficients that differ by nearly 2 orders of magnitude. The shape, position, and intensity of these bands differ with chemical interactions and changing temperature. These challenges make traditional quantification by univariate methods unfeasible. Measuring Np(V) concentration over several orders of magnitude would typically necessitate cells with varying path length, optical switches, and/or multiple spectrophotometers. Alternatively, the differences in the molar extinction coefficients for multiple absorption bands can be used to quantify Np(V) concentration over 3 orders of magnitude with a single optical path length (1 mm) and a hierarchical multivariate model. In this work, principal component analysis was used to distinguish the concentration regime of the sample, directing it to the relevant partial least squares regression submodels. Each submodel was optimized with unique feature selection filters that were selected by a genetic algorithm to enhance predictions. Through this approach, the percent root mean square error of prediction values were ≤1.05% for Np(V) concentrations and ≤4% for temperatures. This approach may be applied to other nuclear fuel cycle and environmental applications requiring real-time spectroscopic measurements over a wide range of conditions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

North Slope of Alaska Snow Intensive Operational Period Field Campaign Report

The campaign was motivated by the need to improve the quantification of measurements of ice-phase precipitation in the Arctic and was by the acquisition and deployment of the new X- and Ka/W-band radars. These radars opened up an opportunity for the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) Climate Research Facility to obtain spatial estimates of snowfall rates using the polarimetric X-band measurements and dual-frequency measurements (using different combinations of the three wavelengths). However, calculations of X- and Ka-band radar back-scattering of ice crystal aggregates with their complex structure suggest that the commonly used T-matrix approach (Matrosov et al. 2007) for modeling the radar back-scattering underestimates the reflectivity by several decibels, with errors increasing with increasing radar frequency (Botta et al. 2010, 2011). Moreover, the X-band polarimetric measurements and the Ka/W-band measurements are sensitive to the assumed shape of the snow (Botta et al. 2011). One of the five ARM two-dimensional video disdrometers (manufactured by Joanneum Research) were deployed in Barrow at the ARM North Slope of Alaska (NSA) site from 1 October, 2011 to 31 May, 2012 in an attempt to use the instrument in a novel way. The instrument was originally designed to measure the drop size distribution of rain but it seemed worthwhile to explore its capability to quantify ice precipitation particle size and shape distributions in the cold north for scattering calculations and precipitation estimations. Furthermore, this deployment gave us an opportunity to see how reliable it could be in arctic conditions.

Ka-band radar↗

Smoothing-based compressed state Kalman filter for joint state-parameter estimation: Applications in reservoir characterization and CO 2 storage monitoring

The operation of most engineered hydrogeological systems relies on simulating physical processes using numerical models with uncertain parameters and initial conditions. Predictions by such uncertain models can be greatly improved by Kalman-filter techniques that sequentially assimilate monitoring data. Each assimilation constitutes a nonlinear optimization, which is solved by linearizing an objective function about the model prediction and applying a linear correction to this prediction. However, if model parameters and initial conditions are uncertain, the optimization problem becomes strongly nonlinear and a linear correction may yield unphysical results. In this paper, we investigate the utility of one-step ahead smoothing, a variant of the traditional filtering process, to eliminate nonphysical results and reduce estimation artifacts caused by nonlinearities. Here, we present the smoothing-based compressed state Kalman filter (sCSKF), an algorithm that combines one step ahead smoothing, in which current observations are used to correct the state and parameters one step back in time, with a nonensemble covariance compression scheme, that reduces the computational cost by efficiently exploring the high-dimensional state and parameter space. Numerical experiments show that when model parameters are uncertain and the states exhibit hyperbolic behavior with sharp fronts, as in CO 2 storage applications, one-step ahead smoothing reduces overshooting errors and, by design, gives physically consistent state and parameter estimates. We compared sCSKF with commonly used data assimilation methods and showed that for the same computational cost, combining one step ahead smoothing and nonensemble compression is advantageous for real-time characterization and monitoring of large-scale hydrogeological systems with sharp moving fronts.

42 ENGINEERING↗

Rapid quantitative analysis of trace elements in plutonium alloys using a handheld laser-induced breakdown spectroscopy (LIBS) device coupled with chemometrics and machine learning

Here, we present the first reported quantification of trace elements in plutonium via a portable laser-induced breakdown spectroscopy (LIBS) device and demonstrate the use of chemometric analysis to enhance the handheld device's sensitivity and precision. Quantification of trace elements such as iron and nickel in plutonium metal via LIBS is a challenging problem due to the complex nature of the plutonium optical emission spectra. While rapid analysis of plutonium alloys has been demonstrated using portable LIBS devices, such as the SciAps Z300, their detection limits for trace elements are severely constrained by their achievable pulse power and length, light collection optics, and detectors. In this paper, analytical methods are evaluated as a means to circumvent the detection constraints. Three chemometric methods often used in analytical spectroscopy are evaluated; principal component regression, partial least-squares regression, and artificial neural networks. These models are evaluated based on goodness-of-fit metrics, root mean-squared error, and their achievable limits of detection (LoDs). Partial least squares proved superior for determining content of iron and nickel in plutonium metal, yielding LoDs of 15 and 20 ppm, respectively. These results of identifying the undesirable trace elements in plutonium components are critical for applications such as fabricating radioisotope thermoelectric generators or nuclear fuel.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Exploring experimental conditions to reduce uncertainties in the optical potential

Uncertainty quantification for nuclear theories has gained a more prominent role in the field, with more groups attempting to understand the uncertainties in their calculations. However, recent studies have shown that the uncertainties on the optical potentials are too large for the theory to be useful. The goal of this work is to explore possible experimental conditions that may reduce the uncertainties on elastic scattering and single-nucleon transfer cross sections that come from the fitting of the optical model parameters to experimental data. Using Bayesian methods, we explore the effect of the uncertainties of optical model parameters on the angular grid of the differential cross section, including cross-section data at nearby energies, and changes in the experimental error bars. We also study the effect on the resulting uncertainty when other observables are included in the fitting procedure, particularly the total (reaction) cross sections. We study proton and neutron elastic scattering on 48 Ca and 208 Pb. We explore the parameter space with the Markov-chain Monte Carlo method, produce posterior distributions for the optical model parameters, and construct the corresponding 95% confidence intervals on the elastic-scattering cross sections. We also propagate the uncertainties on the optical potentials to the 48 Ca(d,p) 49 Ca(g.s.) and 208 Pb(d,p) 209 Pb(g.s.) cross sections. We find little sensitivity to the angular grid and an improvement of up to a factor of 2 on the uncertainties by including data at a nearby energy. Although reducing the error bars on the data does reduce the uncertainty, the gain is often considerably smaller than one would naively expect. We also find that the inclusion of total reaction cross section can improve the uncertainty although the magnitude of the effect depends strongly on the cases considered.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Uncertainty Quantification with MCMC method and BFBT Data

The reliability of predictions of the system codes is closely related to the validation of their physical models. For example, the accuracy of void fraction prediction in a Boiling Water Reactor (BWR) using TRACE code depends on the uncertainties of closure relations developed for the two-phase flow models. This work focus on quantifying the uncertainties of two physical models, interfacial drag model and subcooled boiling model, using Markov Chain Monte Carlo (MCMC) method and BFBT experimental benchmark data. We applied the MCMC and MLE algorithms to BFBT benchmark data and estimated the uncertainty distribution of two model parameters: subcooled boiling heat transfer coefficient and interfacial drag (bubbly/slug rod bundle) coefficient. These algorithms tend to give various estimation results. Despite the differences in these algorithms, we find that the estimation results are consistent. After obtaining the uncertainty estimates, we validated the uncertainty estimates by applying the estimated distributions of model parameters to TRACE prediction. The new predictions succeed in reducing the void fraction prediction error, but it is not possible to eliminate all prediction error. We are only adjusting two model parameters, and there exists uncertainties in all model parameters. Application of the algorithms to other physical models and experimental data will be helpful for future work. (authors)

42 ENGINEERING↗