Search NASA⌕ Search

SEARCH · Search NASA

Results for “failure temperature”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

High Speed Thermal Imaging on Ballistic Impact of Triaxially Braided Composites

Ballistic impact experiments were performed on triaxially braided polymer matrix composites to study the heat generated in the material due to projectile velocity and penetration damage. Quantifying the heat generation phenomenon is crucial for attaining a better understanding of composite behavior and failure under impact loading. The knowledge gained can also be used to improve physics-based models which can numerically simulate impact of composites. Triaxially braided (0/+60/-60) composite panels were manufactured with T700S standard modulus carbon fiber and two epoxy resins. The PR520 (toughened) and 3502 (untoughened) resin systems were used to make different panels to study the effects of resin properties on temperature rise. Ballistic impact tests were conducted on these composite panels using a gas gun, and different projectile velocities were applied to study the effect on the temperature results. Temperature contours were obtained from the rear surface of the panel during the test through a high speed, infrared (IR) thermal imaging system. The contours show that high temperatures were locally generated and more pronounced along the axial tows for the T700S/PR520 composite specimens; whereas, tests performed on T700S/3502 composite panels using similar impact velocities demonstrated a widespread area of lower temperature rises. Nondestructive, ultrasonic C-scan analyses were performed to observe and verify the failure patterns in the impacted panels. Overall, the impact experimentation showed temperatures exceeding 525 K (485degF) in both composites which is well above the respective glass transition temperatures for the polymer constituents. This expresses the need for further high strain rate testing and measurement of the temperature and deformation fields to fully understand the complex behavior and failure of the material in order to improve the confidence in designing aerospace components with these materials.

thermal imaging↗

Evaluation of high-contact-ratio spur gears with profile modification

Scoring tests, surface fatigue tests, and single-tooth bending fatigue tests were conducted with four sets of spur gears of standard design and three sets of spur gears of the new tooth form (NTF) design. Scoring tests were conducted in a gear test rig at a speed of 10,000 rpm using a synthetic polyester C5, C6, C7 substituted pentaerythritol oil. Surface fatigue tests were conducted in the same rig at a speed of 10,000 rpm and Hertz stresses of 173 x 10 to the 7th power and 143 x 10 to the 7th power Pa (250,000 and 214,000 psi). Single tooth bending fatigue tests were conducted on both the standard and NTF gears at an initial load that produced a 10.35 x 10 to the eight power Pa (150,000-psi) bending stress. The gears were load cycled to failure or for 3 x 10 to the 6th power cycles, whichever occurred first. The load was increased after test until failure occurred at 3 x 10 to the 6th power cycles or less. Both the standard and NTF gears scored at a gear bulk temperature of approximately 409 K (277 F). At this temperature the load on the NTF gears was 22 percent less than the load on the standard gears. The scoring failure was a function of gear bulk temperature, where for a given lubricant the temperature is a function of gear design, operating load, and speed.

Townsend, D. P.↗

Sliding wear of self-mated Al2O3-SiC whisker reinforced composites at 23-1200 C

Microstructural changes occurring during sliding wear of self-mated Al2O3-SiC whisker reinforced composites were studied using optical, scanning electron microscopy, and transmission electron microscopy. Pin-on-disk specimens were slid in air at 2.7 m/sec sliding velocity under a 26.5 N load for 1 hr. Wear tests were conducted at 23, 600, 800, and 1200 C. Mild wear with a wear factor of 2.4 times 10(exp -7) to 1.5 times 10(exp -6) cu mm/Nm was experienced at all test temperatures. The composite shows evidence of wear by fatigue mechanisms at 800 C and below. Tribochemical reaction (SiC oxidation and reaction of SiO2 and Al2O3) leads to intergranular failure at 1200 C. Distinct microstructural differences existing at each test temperature are reported.

Farmer, Serene C.↗

Sliding wear of self-mated Al2O3-SiC whisker-reinforced composites at 23-1200 C

Microstructural changes occurring during sliding wear of self-mated Al2O3 SiC whisker-reinforced composites were studied using optical, scanning electron microscopy and transmission electron microscopy. Pin-on-disc specimens were slid in air at 2.7 m/s sliding velocity under a 26.5 N load for 1 h. Wear tests were conducted at 23, 600, 800 and 1200 C. Mild wear with a wear factor of 2.4 x 10 exp -7 - 1.5 x 10 exp -6 cu mm /N per m was experienced at all test temperatures. The composite showed evidence of wear by fatigue mechanisms at 800 C and below. Tribochemical reaction (SiC oxidation and reaction of SiO2 and Al2O3) leads to intergranular failure at 1200 C. Distinct microstructural differences existing at each test temperature are reported.

Farmer, S. C.↗

ASTM and VAMAS activities in titanium matrix composites test methods development

Titanium matrix composites (TMC's) are being considered for a number of aerospace applications ranging from high performance engine components to airframe structures in areas that require high stiffness to weight ratios at temperatures up to 400 C. TMC's exhibit unique mechanical behavior due to fiber-matrix interface failures, matrix cracks bridged by fibers, thermo-viscoplastic behavior of the matrix at elevated temperatures, and the development of significant thermal residual stresses in the composite due to fabrication. Standard testing methodology must be developed to reflect the uniqueness of this type of material systems. The purpose of this paper is to review the current activities in ASTM and Versailles Project on Advanced Materials and Standards (VAMAS) that are directed toward the development of standard test methodology for titanium matrix composites.

Johnson, W. S.↗

Unlocking large compressive strains in thin active elastocaloric layers

Elastocaloric cooling attracts broad interest and rapidly growing attention due to its potential for high efficiency and low environmental impact. While it is common knowledge that triggering reversible entropy and temperature changes with stress applied in compression prevents rapid failures of materials, realizing this regime in elastocaloric systems is highly challenging because nearly all geometries suited for efficient heat transfer are prone to buckling even under modest loads. This work describes a concept of a novel composite, where an active NiTi layer is embedded into a polymer support structure such that the elastocaloric material is entirely in compression when the assembly is subjected to bending. The active layer achieves 8.1 K temperature change at 2.5% compressive strain without buckling. After 10,000 cycles at 2% compressive strain, the composite maintains mechanical integrity without degradation of the elastocaloric effect. The results demonstrate that NiTi and, potentially, other elastocalorically active materials in geometries previously thought impossible can be successfully implemented in regenerative cooling systems operating in compression.

42 ENGINEERING↗

Characterization of Properties of Laser Powder Bed Fusion 3D-Printed Inconel 718 for Centrifugal Turbomachinery Applications

Here, this paper presents the results of a comprehensive effort to characterize the properties of Inconel 718 produced by a form of laser powder bed fusion (LPBF) additive manufacturing (AM) or 3D-printing, subsequently subjected to hot isostatic pressing (HIP) and heat treatment according to standards F3055-14a and AMS 5663, respectively. Material property data, while broadly available for traditional Inconel 718 presentations (e.g. forgings or castings), is currently lacking for the 3D-printed material. It is expected that while limited in size, the experimental data sets presented provide sufficient information to glean the capability of LPBF Inconel 718. These include: 1) Chemical composition, electron backscatter diffraction (EBSD), and x-ray energy dispersive spectroscopy (XEDS) characterization of 3D-printed material structure; 2) Tensile properties — 0.2% yield stress, ultimate stress, modulus of elasticity, and elongation to failure — based on 108 samples, as functions of temperature and sample print orientation; 3) Creep rupture data including the Larson-Miller parameter, based on 21 samples; and 4) High cycle fatigue data based on 21 samples as a function of temperature. Results are compared to available standards and/or data for forged, cast, and other AM Inconel 718. A key observation of this study, based on the EBSD results, is that while the material appears to approach full recrystallization following heat treatment, there is a detectable fraction of the material that does not fully recrystallize, resulting in a material with mechanical properties (e.g. yield stress, creep rupture) measurably lower than those of forgings, but higher than those of castings.

30 DIRECT ENERGY CONVERSION↗

Device for obtaining separation of oxygen

Permeation membrane of a magnesium-nickel alloy of silver has the ability to permeate oxygen at high temperatures for an extended period of operation without failure. The measured rates of oxygen permeation in a tubular configuration of this alloy are higher than any previous rates published.

Glueckert, A. J.↗

Design and testing a high fuel volume fraction, externally finned, thermionic emitter.

A prototypical, high fuel volume fraction, thermionic emitter body was designed and tested. The emitter body is all tungsten, with a 1.40-cm ID, a 3.23-cm OD, and eight full-length axial fins. The emitter thickness is 0.15 cm while the fins and outer clad are 0.075 cm thick. Different methods of fabrication were used in making the test samples. Stress analysis was performed with a three-dimensional elastic code. Thermal testing of the samples, duplicating calculated radial temperature gradients, heatup and cooldown rates, and emitter body temperatures in operation, was performed with no structural failures noted (six heatup and cooldown cycles per sample). Further emitter analysis and testing is planned.

Peelgren, M. L.↗

Exploratory development of a glass ceramic automobile thermal reactor

This report summarizes the design, fabrication and test results obtained for glass-ceramic (CER-VIT) automotive thermal reactors. Several reactor designs were evaluated using both engine-dynamometer and vehicle road tests. A maximum reactor life of about 330 hours was achieved in engine-dynamometer tests with peak gas temperatures of about 1065 C (1950 F). Reactor failures were mechanically induced. No evidence of chemical degradation was observed. It was concluded that to be useful for longer times, the CER-VIT parts would require a mounting system that was an improvement over those tested in this program. A reactor employing such a system was designed and fabricated.

Gould, R. E.↗

A promising new cryogenic seal candidate

The Space Shuttle carries more than 500,000 kg of liquid oxygen (LO2) and 100,000 kg of liquid hydrogen (LH2) propellant. Seals for this main propellant system therefore must provide extremely high reliability under prolonged service at cryogenic temperatures. The chief threat to consistently reliable operation is not the cryogenic service itself, but the 325 K temperature variation encountered during each individual mission. Moreover, this reliability must be sustained during the entire 100-mission/ten-year projected life of the Space Shuttle. It was feared that conventional liquid oxygen seal materials (filled Teflon and Kel-F) could cold flow or compression set to such an extent during the high-temperature phases of the 100 successive missions that failures could result. Thus, in addition to LO2 compatibility and cryogenic serviceability, this program was directed toward seals that were not thermoplastic and had good compression set resistance

Merz, P. L.↗

Ferrographic analysis of wear debris from full-scale bearing fatigue tests

The Ferrograph was used to determine the types and quantities of wear particles generated during full scale bearing fatigue tests. Deep-groove ball bearings made from steel were used. A tetraester lubricant was used in a recirculating lubricant system containing a 49 micrometers absolute filter. Test conditions include a maximum Hertz stress of 2.4 GPa, a shaft speed of 15,000 rpm, and a lubricant supply temperature of 74 C (165 F). Four fatigue failures were detected by accelerometers in this test set. In general, the Ferrograph was more sensitive (up to 23 hr) in detecting spall initiation than either accelerometers or the normal spectrographic oil analysis. Four particle types were observed: normal rubbing weather particles, spheres, nonferrous particles, and severe wear (spall) fragments.

Jones, W. R., Jr.↗

Analysis of wear-debris from full-scale bearing fatigue tests using the ferrograph

The ferrograph was used to determine the types and quantities of wear particles generated during full-scale bearing fatigue tests. Deep-groove ball bearings made from AISI 52100 steel were used. A MIL-L-23699 tetraester lubricant was used in a recirculating lubrication system containing a 49 mm absolute filter. Test conditions included a maximum Hertz stress of 2.4 GPa, a shaft speed of 15,000 rpm, and a lubricant supply temperature of 74 C (165 F). Four fatigue failures were detected by accelerometers in this test set. In general, the ferrograph was more sensitive (up to 23 hr) in detecting spall initiation than either accelerometers or the normal spectrographic oil analysis. Four particle types were observed: normal rubbing wear particles, spheres, nonferrous particles, and severe wear (spall) fragments.

Jones, W. R.↗

Analysis of wear debris from full-scale bearing fatigue tests using the Ferrograph

The Ferrograph was used to determine the types of quantities of wear particles generated during full-scale bearing fatigue tests. Deep-groove ball bearings made from AISI 52100 steel were used. A MIL-L-23699 tetraester lubricant was used in a recirculating lubrication system containing a 49-micron absolute filter. Test conditions included a maximum Hertz stress of 2.4 GPa, a shaft speed of 15,000 rpm and a lubricant supply temperature of 74 C (165 F). Four fatigue failures were detected by accelerometers in this test set. In general, the Ferrograph was more sensitive (up to 23 h) in detecting spall initiation than either accelerometers or the normal spectrographic oil analysis (SOAP). Four particle types were observed: normal rubbing wear particles, spheres, nonferrous particles, and severe wear (spall) fragments.

Jones, W. R., Jr.↗

An accelerated test design for use with synchronous orbit

The Naval Weapons Support Center at Crane, Indiana has conducted a large scale accelerated test of 6.0 Ah Ni-Cd cells. Data from the Crane test have been used to develop an equation for the description of Ni-Cd cell behavior in geosynchronous orbit. This equation relates the anticipated time to failure for a cell in synchronous orbit to temperature and overcharge rate sustained by the cell during the light period. A test design is suggested which uses this equation for setting test parameters for future accelerated testing.

Mcdermott, P. P.↗

Impact penetration studies of graphite/epoxy laminates

A study was conducted to provide an initial insight into the role of the matrix in impact energy absorption of graphite/epoxy laminates. A single epoxy system, NARMCO 5208, in both composite and cured neat-resin form was studied with a constant velocity impact test apparatus. The parameters investigated include resin cure temperature, fiber type, ply thickness and orientation, and impact velocity. The results from the study show that matrix chemistry, as obtained by cure temperature changes, has a significant effect upon the failure mode and energy absorption during impact.

Sykes, G. F.↗

Validation of structural analysis methods using burner liner cyclic rig test data

The objectives of the hot section technology (HOST) burner liner cyclic rig test program are basically threefold: (1) to assist in developing predictive tools needed to improve design analyses and procedures for the efficient and accurate prediction of burner liner structural response; (2) to calibrate, evaluate and validate these predictive tools by comparing the predicted results with the experimental data generated in the tests; and (3) to evaluate existing as well as advanced temperature and strain measurement instrumentation, both contact and noncontact, in a simulated engine cycle environment. The data generated will include measurements of the thermal environment (metal surface temperatures) as well as structural (strain) and life (fatigue) responses of simulated burner liners and specimens under controlled boundary and operating conditions. These data will be used to calibrate, compare and validate analytical theories, methodologies and design procedures, as well as improvements in them, for predicting liner temperatures, stress-strain responses and cycles to failure. Comparison of predicted results with experimental data will be used to show where the predictive theories, etc. need improvements. In addition, as the predictive tools, as well as the tests, test methods, and data acquisition and reduction techniques, are developed and validated, a proven, integrated analysis/experiment method will be developed to determine the cyclic life of a simulated burner liner.

Thompson, R.↗

Adhesive evaluation of water-soluble LARC-TPI

The water-soluble polyimide, identified as TPI(MTC)/H2O, was evaluated as a high temperature thermoplastic adhesive for bonding Ti-6Al-4V and comparing those results primarily with results reported in earlier work with the polyamic-acid/diglyme material. The lap shear strength test was the primary test performed to evaluate the adhesive before (controls) and after thermal exposure in air at 204 C for up to 5000 hours and after a 72 hour water-boil exposure. Lap shear strengths were determined at RT, 177, 204, and 232 C. The adhesive was also characterized after fracture by determining the glass transition temperature as well as defining the mode of failure by visual observation. In general, the results indicate that the TPI(MTC)/H2O retains high lap shear strengths after thermal exposure but had reduced strengths after the water-boil exposure. All failures were cohesive. The TPI(MTC)/H2O compared very well with previous data reported for the standard polyamic-acid/diglyme LARC-TPI results, and therefore, shows promise as a water-soluble adhesive for use in various applications.

Progar, Donald J.↗