Search NASA⌕ Search

SEARCH · Search NASA

Results for “frequency range”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Statistical Study of Auroral Kilometric Radiation Fine Structure Striations Observed by Polar

We have conducted a statistical survey of a semirandom sample of the auroral kilometric radiation (AKR) data observed by the plasma wave instrument wideband receiver on board the Polar spacecraft. We have determined that AKR fine structure patterns with very narrowband, negative drifting striations occur in approximately 6% of the high-resolution wideband spectrograms when AKR is present. Positive sloping striations are also observed, but at a much lower rate. More than 8200 AKR stripes have been scaled. The stripes are predominantly found in the 40 to 215-kHz frequency range and have a frequency extent of about 4 kHz and a duration of usually less than 2 s. The majority of the stripes have drift rates between -8 and -2 kHz/s, with a peak in the distribution between -6 and -4 kHz/s. There is also a much smaller group of striations with positive drift rates of up to about 5 or 6 kHz/s. We have further investigated the change of drift rate with frequency. Almost all striations are observed in the lowest two frequency bands of the wideband receiver (f < 215 kHz). There is an increase in the statistical drift rate with increasing frequency. The statistical slope of the striations increases with frequency from about -4.4 kHz/s at 75 kHz to about -5.7 kHz/s at 170 kHz. This frequency dependence of the drift rate is consistent, under certain conditions, with a production mechanism stimulated by an upward propagating electromagnetic ion cyclotron wave, as had been suggested earlier. However, such a changing drift rate is also compatible with a stimulated source region that propagates upward along the magnetic field line at the velocity of an ion beam accelerated by a local, upward directed electric field, as is typically observed in the auroral region. An explanation for this association is not apparent at this time.

Menietti, J. D.↗

Real-Time Stability Margin Measurements for X-38 Robustness Analysis

A method has been developed for real-time stability margin measurement calculations. The method relies on a tailored-forced excitation targeted to a specific frequency range. Computation of the frequency response is matched to the specific frequencies contained in the excitation. A recursive Fourier transformation is used to make the method compatible with real-time calculation. The method was incorporated into the X-38 nonlinear simulation and applied to an X-38 robustness test. X-38 stability margins were calculated for different variations in aerodynamic and mass properties over the vehicle flight trajectory. The new method showed results comparable to more traditional stability analysis techniques, and at the same time, this new method provided coverage that is more complete and increased efficiency.

Bosworth, John T.↗

High-Resolution Inspection of the Space Shuttle External Tank Spray-on-Foam Insulation (SOFI) using Focused Millimeter Waves at D-Band (150 GHz)

Space Shuttle Columbia's catastrophic failure has been attributed to a piece of spray-on-foam insulation (SOFI) that was dislodged from the external tank and struck the leading edge of the left wing. A piece of SOFI was also dislodged in the recent Space Shuttle Discovery's flight. Clearly, there is a great and urgent need to inspect the external tank SOFI and other similar insulating structures (including the acreage heat tile) in a reliable and robust fashion. In the past two years, millimeter wave nondestructive testing methods, using both real and synthetic focusing techniques, have shown great potential for this purpose. Recently obtained real-focused images from several different and complex SOFI panels have demonstrated the utility of these methods as being viable, robust, repeatable, simple, portable and effective. D-band frequency range which covers a frequency spectrum of 110- 170 GHz is well-suited for this purpose given the nature of the foam which causes significant scattering at much higher frequencies. This paper presents the results of using continuous-wave (CW) reflectometry conducted on several typical and complex SOFI panes at 150 GHz.

Kharkovsky, S.↗

'Exploration of finite ion orbit effects in the ion cyclotron range of frequencies

The rf-SciDAC collaboration is developing computer simulations to predict the damping of radio frequency (rf) waves in fusion plasmas. Here we extend self-consistent quasi-linear calculations of ion cyclotron resonant heating to include the finite drift of ions from magnetic flux surfaces and rf induced spatial transport. The all-orders spectral wave solver AORSA is iteratively coupled with a particle based update of the plasma distribution function.

43 PARTICLE ACCELERATORS↗

Exploration of finite ion orbit effects in the ion cyclotron range of frequencies

The rf-SciDAC collaboration is developing computer simulations to predict the damping of radio frequency (rf) waves in fusion plasmas. Here we extend self-consistent quasi-linear calculations of ion cyclotron resonant heating to include the finite drift of ions from magnetic flux surfaces and rf induced spatial transport. The all-orders spectral wave solver AORSA is iteratively coupled with a particle based update of the plasma distribution function.

ABSORPTION↗

Device and method for generating a beam of acoustic energy from a borehole, and applications thereof

In some aspects of the invention, a method of generating a beam of acoustic energy in a borehole is disclosed. The method includes generating a first acoustic wave at a first frequency; generating a second acoustic wave at a second frequency different than the first frequency, wherein the first acoustic wave and second acoustic wave are generated by at least one transducer carried by a tool located within the borehole; transmitting the first and the second acoustic waves into an acoustically non-linear medium, wherein the composition of the non-linear medium produces a collimated beam by a non-linear mixing of the first and second acoustic waves, wherein the collimated beam has a frequency based upon a difference between the first frequency range and the second frequency, and wherein the non-linear medium has a velocity of sound between 100 m/s and 800 m/s.

47 OTHER INSTRUMENTATION↗

Intrinsic dielectric frequency dependent spectrum of a single domain tetragonal BaTiO3

The intrinsic dielectric frequency dependent spectrum of single domain barium titanate (BaTiO3) at room temperature is investigated by considering the vibration of phonons and the conductivity of the tetragonal system in a wide frequency range up to THz. The proposed model combines Debye type of dissipation, soft mode theory, and the influence of conductivity on the dielectric loss to obtain a more precise dielectric frequency spectrum. The calculated results were compared with experimental data on single domain nanocrystals of BaTiO3, both free standing and suspended in a low dielectric medium. The comparisons provide insight into the mechanism for the dielectric behavior, which can be extended to apply to a range of composites that comprise single domain dielectrics embedded in continuous media. At the lower frequency range, conductivity plays a dominant role in the contribution to the dielectric loss along both a-and c-axes, while the phonon vibration controls the dielectric behavior of the system at higher frequency range. When the conductivity of the system increases, the dielectric loss increases below the MHz range, with such an effect diminishing when the frequency reaches the GHz regime. (C) 2012 American Institute of Physics. [http://dx.doi.org/10.1063/1.4734004]

Liu, SY↗

All-dielectric periodic terajet waveguide using an array of coupled cuboids

In this paper, the recently proposed technique to produce photonic jets (terajets at terahertz (THz) frequencies) using 3D dielectric cuboids is applied in the design of a mesoscale cuboid-chain waveguide. The chains are basically designed with several dielectric cubes with side λ{sub 0} placed periodically along the axial z-axis and separated by an air-gap. Based on this, a systematic study of the focusing properties and wave guiding of this chain is performed when the air-gap between the dielectric cubes is changed from 0.25λ{sub 0} to 3λ{sub 0} with the best performance achieved at 2.5λ{sub 0}. An analysis when losses are included in the cubes is also done, demonstrating a robust performance. Finally, the wave guiding is experimentally demonstrated at sub-THz frequencies with a good agreement with numerical results. The simulation results of focusing and transport properties are carried out using Finite Integration Technique. The results here presented may be scaled to any frequency ranges such as millimeter, sub-millimeter, and optical frequencies.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Broadband (0–5 Hz) Fully Deterministic 3D Ground‐Motion Simulations of a Magnitude 7.0 Hayward Fault Earthquake: Comparison with Empirical Ground‐Motion Models and 3D Path and Site Effects from Source Normalized Intensities

We report on high‐performance computing (HPC) fully deterministic simulation of ground motions for a moment magnitude (⁠Mw⁠) 7.0 scenario earthquake on the Hayward fault resolved to 5 Hz using the SW4 finite‐difference code. We computed motions obeying physics‐based 3D wave propagation at a regional scale with an Mw 7.0 kinematic rupture model generated following Graves and Pitarka (2016). Both plane‐layered (1D) and 3D Earth models were considered, with 3D subsurface material properties and topography interpolated from a model of the U.S. Geological Survey (USGS). The resulting ground‐motion intensities cover a broader frequency range than typically considered in regional‐scale simulations, including higher frequencies relevant for engineering analysis of structures. Median intensities for sites across the domain are within the reported between‐event uncertainties (⁠τ⁠) of ground‐motion models (GMMs) across spectral periods 0.2–10 s (frequencies 0.1–5 Hz). The within‐event standard deviation ϕ of ground‐motion intensity measurement residuals range 0.2–0.5 natural log units with values consistently larger for the 3D model. Source‐normalized ratios of intensities (3D/1D) reveal patterns of path and site effects that are correlated with known geologic structure. These results demonstrate that earthquake simulations with fully deterministic wave propagation in 3D Earth models on HPC platforms produce broadband ground motions with median and within‐event aleatory variability consistent with empirical models. Systematic intensity variations for the 3D model caused by path and site effects suggest that these epistemic effects can be estimated and removed to reduce variation in site‐specific hazard estimates. This study motivates future work to evaluate the validity of the USGS 3D model and investigate the development of path and site corrections by running more scenarios.

Rodgers, Arthur J.↗

Review of High-Speed Fiber Optic Grating Sensors Systems

Fiber grating sensors can be used to support a wide variety of high speed measurement applications. This includes measurements of vibrations on bridges, traffic monitoring on freeways, ultrasonic detection to support non-destructive tests on metal plates and providing details of detonation events. This paper provides a brief overview of some of the techniques that have been used to support high speed measurements using fiber grating sensors over frequency ranges from 10s of kHz, to MHZ and finally toward frequencies approaching the GHz regime. Very early in the development of fiber grating sensor systems it was realized that a high speed fiber grating sensor system could be realized by placing an optical filter that might be a fiber grating in front of a detector so that spectral changes in the reflection from a fiber grating were amplitude modulated. In principal the only limitation on this type of system involved the speed of the output detector which with the development of high speed communication links moved from the regime of 10s of MHz toward 10s of GHz. The earliest deployed systems involved civil structures including measurements of the strain fields on composite utility poles and missile bodies during break tests, bridges and freeways. This was followed by a series of developments that included high speed fiber grating sensors to support nondestructive testing via ultrasonic wave detection, high speed machining and monitoring ship hulls. Each of these applications involved monitoring mechanical motion of structures and thus interest was in speeds up to a few 10s of MHz. Most recently there has been interest in using fiber grating to monitor the very high speed events such as detonations and this has led to utilization of fiber gratings that are consumed during an event that may require detection speeds of hundreds of MHz and in the future multiple GHz.

42 ENGINEERING↗

Tunable all-angle negative refraction and photonic band gaps in two-dimensional plasma photonic crystals with square-like Archimedean lattices

In this paper, the tunable all-angle negative refraction and photonic band gaps (PBGs) in two types of two-dimensional (2D) plasma photonic crystals (PPCs) composed of homogeneous plasma and dielectric (GaAs) with square-like Archimedean lattices (ladybug and bathroom lattices) for TM wave are theoretically investigated based on a modified plane wave expansion method. The type-1 structure is dielectric rods immersed in the plasma background, and the complementary structure is named as type-2 PPCs. Theoretical simulations demonstrate that the both types of PPCs with square-like Archimedean lattices have some advantages in obtaining the higher cut-off frequency, the larger PBGs, more number of PBGs, and the relative bandwidths compared to the conventional square lattices as the filling factor or radius of inserted rods is same. The influences of plasma frequency and radius of inserted rod on the properties of PBGs for both types of PPCs also are discussed in detail. The calculated results show that PBGs can be manipulated by the parameters as mentioned above. The possibilities of all-angle negative refraction in such two types of PPCs at low bands also are discussed. Our calculations reveal that the all-angle negative phenomena can be observed in the first two TM bands, and the frequency range of all-angle negative refraction can be tuned by changing plasma frequency. Those properties can be used to design the optical switching and sensor.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The emissions of broadband electrostatic noise in the near vicinity of the Shuttle Orbiter

Measurements of the Space Shuttle environment from the STS-3 and Spacelab 2 missions indicate the presence of oblique ion streams and broadband electrostatic noise. A two-dimensional theoretical model is applied to study a possible causal relationship between the ion streams and the broadband noise, especially in terms of the ion acoustic wave and ion-ion wave modes. This model predicts the generation of waves with frequencies ranging from the ion cyclotron frequency up to values greater than the ion plasma frequency, with the maximum growth rate occurring in the 10-kHz range. These results are consistent with the observational data from the STS-3 mission. The model also shows that these two wave modes can coexist only when the wave vectors of the two wave modes are nearly perpendicular. The parametric dependence of the wave instabilities on the plasma parameters and the inclination of the wave propagation vector is also studied.

Hwang, K. S.↗

Electron density dependence of impedance probe plasma potential measurements

In earlier works, we used spheres of various sizes as impedance probes in demonstrating a method of determining plasma potential, φ{sub p}, when the probe radius is much larger than the Debye length, λ{sub D}. The basis of the method in those works [Walker et al., Phys. Plasmas 13, 032108 (2006); ibid. 15, 123506 (2008); ibid. 17, 113503 (2010)] relies on applying a small amplitude signal of fixed frequency to a probe in a plasma and, through network analyzer-based measurements, determining the complex reflection coefficient, Γ, for varying probe bias, V{sub b}. The frequency range of the applied signal is restricted to avoid sheath resonant effects and ion contributions such that ω{sub pi} ≪ ω ≪ ω{sub pe}, where ω{sub pi} is the ion plasma frequency and ω{sub pe} is the electron plasma frequency. For a given frequency and applied bias, both Re(Z{sub ac}) and Im(Z{sub ac}) are available from Γ. When Re(Z{sub ac}) is plotted versus V{sub b}, a minimum predicted by theory occurs at φ{sub p} [Walker et al., Phys. Plasmas 17, 113503 (2010)]. In addition, Im(Z{sub ac}) appears at, or very near, a maximum at φ{sub p}. As n{sub e} decreases and the sheath expands, the minimum becomes harder to discern. The purpose of this work is to demonstrate that when using network analyzer-based measurements, Γ itself and Im(Z{sub ac}) and their derivatives are useful as accompanying indicators to Re(Z{sub ac}) in these difficult cases. We note the difficulties encountered by the most commonly used plasma diagnostic, the Langmuir probe. Spherical probe data is mainly used in this work, although we present limited data for a cylinder and a disk. To demonstrate the effect of lowered density as a function of probe geometry, we compare the cylinder and disk using only the indicator Re(Z{sub ac})

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Glass transition and composite formation in InF{sub 3}-containing oxyfluoroniobate system

The glasses in the system MnNbOF{sub 5}-BaF{sub 2}-InF{sub 3} have been firstly synthesized and studied. The thermal parameters of these glasses are analyzed. It was stated that glass of the composition 40MnNbOF{sub 5}-40BaF{sub 2}-20InF{sub 3} is the most thermal stable in the system under study. By X-ray analysis the compositions of the crystalline phases obtained at the glass thermal treatment were determined: the main phases are Ba{sub 3}In{sub 2}F{sub 12} and BaNbOF{sub 5}. By Raman and IR spectra analysis it was stated that the networks of glasses in the system are built by the structural type of the glasses in NbO{sub 2}F-BaF{sub 2} system: (NbO{sub n}F{sub m}) polyhedra joined oxygen bridges. Indium trifluoride forms InF{sub 6} polyhedra, which are embeded between oxyfluoroniobate ions, forming a common networks or forms its own layers from InF{sub 6} polyhedra. IR-spectroscopy method showed that at devitrification of the sample 30MnNbOF{sub 5}-50BaF{sub 2}-20InF{sub 3} the band position and shape change in going from glass state to crystalline. The bands in the range 900–700 cm{sup −1} shift into the low-frequency range and transformed into narrow peaks characteristic for the crystalline state. It was determined that for this sample the IR-spectroscopy method fixes the presence of the crystalline phases at 340°C without time of exposure, despite the fact that X-ray analysis shows an amorphous state for this sample at the same temperature. It was suggested, that controlling the composition and conditions of annealing of the glasses it can be obtain the transparent glass-ceramics of definite composition.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Determining moisture content of Traditional Chinese Medicines using a near-infrared LED-based moisture content sensor with spectrum analysis

In Traditional Chinese Medicine (TCM), moisture content (MC) inspection using voltage level or a lock-in amplifier, with a features-based near-infrared light-emitting diode sensor is possible. Abundant absorption response in a wide frequency range and information in both the time-domain and frequency-domain can be obtained, with the square excitation method. However, planeness, heterogeneous particle sizes, and measurement noise negatively affect the time-domain feature during MC inspection. In this work, spectrum analysis (SA) for feature extraction is investigated, to precisely measure the MC of Dutong pills. The principal components for low and high frequencies, are aimed at counteracting the dimensional methods, which are used for supplying the lower dimensional features. The SA experimental results demonstrate that the low frequency components, ranging from the base to the 3rd harmonic components, have a high linear correlation with the MC. The calibration and validation experimental results reveal that the MC can be a monotonic function about the SA amplitudes or first principal component (PC1), with the proposed sensor. This method has the potential to be used for gauging automatic, in situ MCs, particularly for quality control and Process Analytical Technology in TCM. Future research opportunities include improving accuracy and application of the method under field conditions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A compact high-performance low-field NMR apparatus for measurements on fluids at very high pressures and temperatures

We discuss an innovative new high-performance apparatus for performing low-field Nuclear Magnetic Resonance (NMR) relaxation times and diffusion measurements on fluids at very high pressures and high temperatures. The apparatus sensor design and electronics specifications allow for dual deployment either in a fluid sampling well logging tool or in a laboratory. The sensor and electronics were designed to function in both environments. This paper discusses the use of the apparatus in a laboratory environment. The operating temperature and pressure limits, and the signal-to-noise ratio (SNR) of the new system exceed by a very wide margin what is currently possible. This major breakthrough was made possible by a revolutionary new sensor design that breaks many of the rules of conventional high pressure NMR sensor design. A metallic sample holder capable of operating at high pressures and temperatures is provided to contain the fluid under study. The sample holder has been successfully tested for operation up to 36 Kpsi. A solenoid coil wound on a slotted titanium frame sits inside the metallic sample holder and serves as an antenna to transmit RF pulses and receive NMR signals. The metal sample holder is sandwiched between a pair of gradient coils which provide a linear field gradient for pulsed field gradient diffusion measurements. The assembly sits in the bore of a low-gradient permanent magnet. The system can operate over a wide frequency range without the need for tuning the antenna to the Larmor frequency. The SNR measured on a water sample at room temperature is more than 15 times greater than that of the commercial low-field system in our laboratory. Thus, the new system provides for data acquisition more than 200 times faster than was previously possible. Laboratory NMR measurements of relaxations times and diffusion coefficients performed at pressures up to 25 Kpsi and at temperatures up to 175 °C with crude oils enlivened with dissolved hydrocarbon gases (referred to as “live oils”) are shown. This is the first time low-field NMR measurements have been performed at such high temperatures and pressures on live crude oil samples. We discuss the details of the apparatus design, tuning, calibration, and operation. NMR data acquired at multiple temperatures and pressures on a live oil sample are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

ARTEMIS Observations of Plasma Waves in Laminar and Perturbed Interplanetary Shocks

The ‘Acceleration, Reconnection, Turbulence and Electrodynamics of the Moon's Interaction with the Sun’ (ARTEMIS) mission provides a unique opportunity to study the structure of interplanetary shocks and the associated generation of plasma waves with frequencies between ~50-8000 Hz due to its long duration electric and magnetic field burst waveform captures. We compare wave properties and occurrence rates at 11 quasi-perpendicular interplanetary shocks with burst data within 10 minutes (~3200 proton gyroradii upstream, ~1900 downstream) of the shock ramp. A perturbed shock is defined as possessing a large amplitude whistler precursor in the quasi-static magnetic field with an amplitude greater than ⅓ the difference between the upstream and downstream average magnetic field magnitudes; laminar shocks lack these large precursors and have a smooth, step function-like transition. In addition to wave modes previously observed, including ion acoustic, whistler, and electrostatic solitary waves, waves in the ion acoustic frequency range that show rapid temporal frequency change are common. Three shocks had burst captures in the ramp; of these, the two laminar shocks with burst data in the ramp contained a wide range of large amplitude wave modes in the ramp whereas the one perturbed shock contained no such waves. Thus, energy dissipation through wave-particle interactions is more prominent in these two laminar shocks than in the perturbed shock. Based on observations from all 11 shocks, the The wave occurrence rates for laminar shocks are higher in the transition region, especially the ramp, than downstream. In contrast, perturbed shocks have approximately 2-3 times the wave occurrence rate downstream than laminar shocks.

L. A. Davis↗