Search NASA⌕ Search

SEARCH · Search NASA

Results for “information loading”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Performance of High Stopping Power Bismuth-Loaded Plastic Scintillators for Radiation Portal Monitors

Plastic scintillators are widely used in radiation portal monitors because of their low cost and availability in large sizes. However, due to their low density and low effective atomic number (Z), they offer low intrinsic efficiency and little spectroscopic information. The addition of high-Z constituents to these plastics can greatly increase both their total stopping power and the amount of photoelectric absorption, leading to full-energy deposition and thus useful gamma spectra. Herein, we present the performance of the latest formulation of Bi-loaded plastic scintillators showing their useful spectroscopic information up to relatively high energy (~1 MeV) due to their high stopping power compared to the current commercially available plastics. These Bi-loaded plastics use 20 weight percent (wt%) Bi-pivalate (8 wt% elemental Bi) dissolved in polyvinyltoluene (PVT) matrix and conventional fast fluors (~10 ns decay time). These Bi-loaded plastics achieve up to approximately 6000 photons/MeV and have been produced in sizes up to 17 in 3 . The performance of these Bi-loaded plastics is also demonstrated in the existing portal monitor hardware (Rapiscan Model TSA Trainer 770) showing the possibility to provide improved sensitivity as a drop-in replacement with continued scale-up.

42 ENGINEERING↗

Technical note: Optimization for improved tube-loading efficiency in the dual-energy computed tomography coupled with balanced filter method

Purpose: This article describes the spectral optimization of dual-energy computed tomography using balanced filters (bf-DECT) to reduce the tube loadings and dose by dedicating to the acquisition of electron density information, which is essential for treatment planning in radiotherapy. Methods: For the spectral optimization of bf-DECT, the author calculated the beam-hardening error and air kerma required to achieve a desired noise level in an electron density image of a 50-cm-diameter cylindrical water phantom. The calculation enables the selection of beam parameters such as tube voltage, balanced filter material, and its thickness. Results: The optimal combination of tube voltages was 80 kV/140 kV in conjunction with Tb/Hf and Bi/Mo filter pairs; this combination agrees with that obtained in a previous study [M. Saito, ''Spectral optimization for measuring electron density by the dual-energy computed tomography coupled with balanced filter method,'' Med. Phys. 36, 3631-3642 (2009)], although the thicknesses of the filters that yielded a minimum tube output were slightly different from those obtained in the previous study. The resultant tube loading of a low-energy scan of the present bf-DECT significantly decreased from 57.5 to 4.5 times that of a high-energy scan for conventional DECT. Furthermore, the air kerma of bf-DECT could be reduced to less than that of conventional DECT, while obtaining the same figure of merit for the measurement of electron density and effective atomic number. Conclusions: The tube-loading and dose efficiencies of bf-DECT were considerably improved by sacrificing the quality of the noise level in the images of effective atomic number.

60 APPLIED LIFE SCIENCES↗

Mneme

A simple tool allowing recording the execution of a GPU (CUDA) kernel and replaying that kernel as an independent executable. The tool operates in 3 phases. During compile time the user needs to apply a provided LLVM pass to instrument the code. The pass detects all device global variables and device functions and stores this information with the respective LLVM-IR in the global device memory. The compilation generates a record-able executable. The second phase involves running the application executable with a desired input and using LD_PRELOAD to enable recording. When recording before invoking a device kernel the pre-loaded library stores device memory in persistent storage and associates the memory with the device kernel and an LLVM IR file. At the end of the recorded execution the pre-load library generates a database in the form of a JSON file containing information regarding the LLVM-IR files and the snapshots of device memory. During the third and last phase the user can replay the execution of an kernel as a separate independent executable. Besides executing it the user can modify the LLVM IR file and auto-tune parameters such as kernel launch-bounds or kernel runtime execution parameters (e.g. Kernel Block and Grid Dimensions). Is

Parasyris, Konstantinos↗

Cockpit displayed traffic information and distributed management in air traffic control

A graphical display of information (such as surrounding aircraft and navigation routes) in the cockpit on a cathode ray tube has been proposed for improving the safety, orderliness, and expeditiousness of the air traffic control system. An investigation of this method at NASA-Ames indicated a large reduction in controller verbal work load without increasing pilot verbal load; the visual work may be increased. The cockpit displayed traffic and navigation information system reduced response delays permitting pilots to maintain their spacing more closely and precisely than when depending entirely on controller-issued radar vectors and speed command.

Kreifeldt, J. G.↗

ASME AG-1 Section FC Qualified HEPA Filters; a Particle Loading Comparison - 13435

High Efficiency Particulate Air (HEPA) Filters used to protect personnel, the public and the environment from airborne radioactive materials are designed, manufactured and qualified in accordance with ASME AG-1 Code section FC (HEPA Filters) [1]. The qualification process requires that filters manufactured in accordance with this ASME AG-1 code section must meet several performance requirements. These requirements include performance specifications for resistance to airflow, aerosol penetration, resistance to rough handling, resistance to pressure (includes high humidity and water droplet exposure), resistance to heated air, spot flame resistance and a visual/dimensional inspection. None of these requirements evaluate the particle loading capacity of a HEPA filter design. Concerns, over the particle loading capacity, of the different designs included within the ASME AG-1 section FC code[1], have been voiced in the recent past. Additionally, the ability of a filter to maintain its integrity, if subjected to severe operating conditions such as elevated relative humidity, fog conditions or elevated temperature, after loading in use over long service intervals is also a major concern. Although currently qualified HEPA filter media are likely to have similar loading characteristics when evaluated independently, filter pleat geometry can have a significant impact on the in-situ particle loading capacity of filter packs. Aerosol particle characteristics, such as size and composition, may also have a significant impact on filter loading capacity. Test results comparing filter loading capacities for three different aerosol particles and three different filter pack configurations are reviewed. The information presented represents an empirical performance comparison among the filter designs tested. The results may serve as a basis for further discussion toward the possible development of a particle loading test to be included in the qualification requirements of ASME AG-1 Code sections FC and FK[1]. (authors)

42 ENGINEERING↗

Investigating Marine Environmental Degradation of Additive Manufacturing Materials for Renewable Energy Applications

Marine renewable energy is a relatively young industry where there is a great need for rapid prototyping in design-build-test campaigns to quickly mature groundbreaking technologies. Additive manufacturing has an important role to play in the industry; however, little information is available to marine energy developers to help inform them on which additive manufacturing materials are appropriate for highly loaded structures in harsh marine environments. This paper presents an initial study on the mechanical characterization of polymeric additive manufacturing materials and the degradation effects due to the marine environment. Ultem 9085, acrylonitrile styrene acrylate, and chopped carbon-filled nylon, as well as continuous carbon and glass fiber-reinforced nylon were chosen for this study. Samples were manufactured to perform a variety of tension, shear, and compression mechanical characterization tests on the materials. Half of the samples were conditioned in Pacific Ocean water for approximately 6 months at the Pacific Northwest National Laboratory's Marine and Coastal Research Laboratory before being returned for mechanical characterization. The mechanical testing results showed that the Ultem 9085 and acrylonitrile styrene acrylate materials experienced little to no degradation in stiffness or strength after exposure to the marine environment. On the other hand, the nylon-based materials suffered significant stiffness and strength degradation (over 50% in some cases) after environmental conditioning. Ultimately, these data sets should serve as starting points to allow marine renewable energy developers to make informed additive manufacturing material choices for their prototype deployments.

additive manufacturing↗

Nacelle Aerodynamic and Inertial Loads (NAIL) project

A flight test survey of pressures measured on wing, pylon, and nacelle surfaces and of the operating loads on Boeing 747/Pratt & Whitney JT9D-7A nacelles was made to provide information on airflow patterns surrounding the propulsion system installations and to clarify processes responsible for inservice deterioration of fuel economy. Airloads at takeoff rotation were found to be larger than at any other normal service condition because of the combined effects of high angle of attack and high engine airflow. Inertial loads were smaller than previous estimates indicated. A procedure is given for estimating inlet airloads at low speeds and high angles of attack for any underwing high bypass ratio turbofan installation approximately resembling the one tested. Flight procedure modifications are suggested that may result in better fuel economy retention in service. Pressures were recorded on the core cowls and pylons of both engine installations and on adjacent wing surfaces for use in development of computer codes for analysis of installed propulsion system aerodynamic drag interference effects.

Source record↗

A Study of the Use of Contact Loading to Simulate Low Velocity Impact

Although numerous studies on the impact response of laminated composites have been conducted, there is as yet no agreement within the composites community on what parameter or parameters are adequate for quantifying the severity of an impact event. One of the more interesting approaches that has been proposed uses the maximum contact force during impact to "quantify" the severity of the impact event, provided that the impact velocity is sufficiently low. A significant advantage of this approach, should it prove to be reliable, is that quasi-static contact loading could be used to simulate low velocity impact. In principle, a single specimen, loaded quasi-statically to successively increasing contact loads could be used to map the entire spectrum of damage as a function of maximum contact force. The present study had as its objective assessing whether or not the maximum contact force during impact is a suitable parameter for characterizing an impact. The response of [+/-60/0(sub 4)/+/-60/0(sub 2)](sub s) laminates fabricated from Fiberite T300/934 graphite epoxy and subjected to quasi-static contact loading and to low velocity impact was studied. Three quasi-static contact load levels - 525 lb., 600 lb., and 675 lb. - were selected. Three impact energy levels - 1.14 ft.-lb., 2.0 ft.-lb., and 2.60 ft.-lb. - were chosen in an effort to produce impact events in which the maximum contact forces during the impact events were 525 lb., 600 lb., and 625 lb., respectively. Damage development was documented using dye-penetrant enhanced x-ray radiography. A digital image processing technique was used to obtain quantitative information about the damage zone. Although it was intended that the impact load levels produce maximum contact forces equal to those used in the quasi-static contact experiments, larger contact forces were developed during impact loading. In spite of this, the damage zones developed in impacted specimens were smaller than the damage zones developed in specimens subjected to the corresponding quasi-static contact loading. The impacted specimens may have a greater tendency to develop fiber fracture, but, at present, a quantitative assessment of fiber fracture is not available. In addressing whether or not contact force is an adequate metric for describing the severity of an impact event, the results of this study suggest that it is not. In cases where the quasi-static load level and the maximum contact force during impact were comparable, the quasi-statically loaded specimens consistently developed larger damage zones. It should be noted, however, that using quasi-static damage data to forecast the behavior of impacted material may give conservative estimates of the residual strength of impacted composites.

Highsmith, Alton L.↗

Digitalized two parametric system for gamma/neutron spectrometry - Paper 59

Many types of detectors like stilbene, NE-213 etc. in conjunction with photomultiplier loaded with low working resistance produce pulses of approximately 100 ns length and contain information about deposited particle in the trailing edge. Using fast analog to digital converters (ADC) and field-programmable gate array (FPGA) it is possible to create a spectrometric system working in mixed gamma and neutron fields which is not loaded dead time. The count rate of processed pulses can reach more than one million per second. Such a high count rate of processed pulses can be achieved due to the pulse processing is implemented in FPGA. The output of this pulse processing is amplitude which describes the energy of deposited particle and discrimination parameter whereby it is possible to discriminate photons and neutrons. To increase the dynamic range of energy of detectable particle the signal from photomultiplier is separated into two branches with different amplification. Each branch is digitalized by separate ADC. Components from which the system is composed are so light that the spectrometer can be easily transported. Its weight is less than 3 kilograms. Spectrometer was tested in the research reactor LR-0 in Rez near Prague (Czech Republic). The measured data was processed using deconvolution into a neutron flux density and compared with nowadays used analog spectrometer and simulation result. Measured neutron spectrum of Cf-252 is included. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Load Forecasting in Electric Utility Integrated Resource Planning

Integrated resource planning (IRP) is a process used by many vertically-integrated U.S. electric utilities to determine least-cost/risk supply and demand-side resources that meet government policy objectives and future obligations to customers and, in many cases, shareholders. Forecasts of energy and peak demand are a critical component of the IRP process. There have been few, if any, quantitative studies of IRP long-run (planning horizons of two decades) load forecast performance and its relationship to resource planning and actual procurement decisions. In this paper, we evaluate load forecasting methods, assumptions, and outcomes for 12 Western U.S. utilities by examining and comparing plans filed in the early 2000s against recent plans, up to year 2014. We find a convergence in the methods and data sources used. We also find that forecasts in more recent IRPs generally took account of new information, but that there continued to be a systematic over-estimation of load growth rates during the period studied. We compare planned and procured resource expansion against customer load and year-to-year load growth rates, but do not find a direct relationship. Load sensitivities performed in resource plans do not appear to be related to later procurement strategies even in the presence of large forecast errors. These findings suggest that resource procurement decisions may be driven by other factors than customer load growth. Our results have important implications for the integrated resource planning process, namely that load forecast accuracy may not be as important for resource procurement as is generally believed, that load forecast sensitivities could be used to improve the procurement process, and that management of load uncertainty should be prioritized over more complex forecasting techniques.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

AN ESTIMATE OF SPENT NUCLEAR FUEL MECHANICAL LOADS IN THE GENERAL 30 CM PACKAGE DROP SCENARIO

The US Department of Energy Spent Fuel and Waste Science and Technology (SFWST) program is performing research to determine the mechanical loading conditions applied to spent nuclear fuel (SNF) during normal conditions of transport to inform mechanical tests of SNF and close an important knowledge gap related to the practical disposition of SNF in the US. Researchers at Pacific Northwest National Laboratory (PNNL) have completed an extensive finite element study to characterize and estimate the potential mechanical loads on SNF during a hypothetical 30 cm drop of an SNF transportation package. This modeling study is validated with test data collected by the SFWST program during a physical test campaign that included one-third scale package drop tests and full-scale single fuel assembly drop tests. The test campaign was led by Sandia National Laboratories (SNL) and included international collaboration with Equipos Nucleares S.A, S.M.E (ENSA) and Bundesanstalt für Materialforschung und -prüfung (BAM). The key contribution of the modeling study is to go beyond the limitations of the limited number of physical tests to estimate the impact response to variations in impact angle, initial gap conditions, fuel assembly design, burnup and other parameters that affect the mechanical loads. The methodology of this study included a classic parametric study to calculate the impact response of highly detailed fuel assemblies over many combinations of parameters. Models of a 17x17 pressurized water reactor fuel assembly and a generic 10x10 boiling water reactor fuel assembly were both used in this study to cover the major fuel assembly types in the US inventory. Over 2,000 impact responses were calculated. The results of the parametric study were evaluated using traditional methods and basic statistics. The results were also used to construct a damage model using multiple nonlinear regression techniques to predict the mechanical loads over the full range of all input parameters. The damage model was found to work very well for all impact angle cases where the cask came to rest on its side. It was concluded that end drop cases where the cask remained vertical (instead of tipping over onto its side) were not sufficiently characterized by the current set of parametric study cases to include in the damage model, but it was not a priority to fully investigate that range because the highest mechanical loads were observed in the broader range of side impact cases. This modeling work provides sufficient insight into the mechanical loads on SNF during a hypothetical 30 cm package drop that, when considered along with the physical test data collected by the SNL-led team, the SFSWT program can consider the knowledge gap closed.

Klymyshyn, Nicholas A.↗

Quantifying the debonding of inclusions through tomography and computational homology.

This report describes a Laboratory Directed Research and Development (LDRD) project to use of synchrotron-radiation computed tomography (SRCT) data to determine the conditions and mechanisms that lead to void nucleation in rolled alloys. The Advanced Light Source (ALS) at Lawrence Berkeley National Laboratory (LBNL) has provided SRCT data of a few specimens of 7075-T7351 aluminum plate (widely used for aerospace applications) stretched to failure, loaded in directions perpendicular and parallel to the rolling direction. The resolution of SRCT data is 900nm, which allows elucidation of the mechanisms governing void growth and coalescence. This resolution is not fine enough, however, for nucleation. We propose the use statistics and image processing techniques to obtain sub-resolution scale information from these data, and thus determine where in the specimen and when during the loading program nucleation occurs and the mechanisms that lead to it. Quantitative analysis of the tomography data, however, leads to the conclusion that the reconstruction process compromises the information obtained from the scans. Alternate, more powerful reconstruction algorithms are needed to address this problem, but those fall beyond the scope of this project.

43 PARTICLE ACCELERATORS↗

Active Learning Framework for Non-Intrusive Load Monitoring: Preprint

Non-Intrusive Load Monitoring (NILM) is a set of techniques that estimate the electricity usage of individual appliances from power measurements taken at a limited number of locations in a building. One of the key challenges in NILM is having too much data without class labels yet being unable to label the data manually for cost or time constraints. This paper presents an active learning framework that helps existing NILM techniques to overcome this challenge. Active learning is an advanced machine learning method that interactively queries a user for the class label information. Unlike most existing NILM systems that heuristically request user inputs, the proposed method only needs minimally sufficient information from a user to build a compact and yet highly representative load signature library. Initial results indicate the proposed method can reduce the user inputs by up to 90% while still achieving similar disaggregation performance compared to a heuristic method. Thus, the proposed method can substantially reduce the burden on the user, improve the performance of a NILM system with limited user inputs, and overcome the key market barriers to the wide adoption of NILM technologies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Opportunities for Demand Response in California Agricultural Irrigation: A Scoping Study

California agricultural irrigation consumes more than ten billion kilowatt hours of electricity annually and has significant potential for contributing to a reduction of stress on the grid through demand response, permanent load shifting, and energy efficiency measures. To understand this potential, a scoping study was initiated for the purpose of determining the associated opportunities, potential, and adoption challenges in California agricultural irrigation. The primary research for this study was conducted in two ways. First, data was gathered and parsed from published sources that shed light on where the best opportunities for load shifting and demand response lie within the agricultural irrigation sector. Secondly, a small limited survey was conducted as informal face-to-face interviews with several different California growers to get an idea of their ability and willingness to participate in permanent load shifting and/or demand response programs. Analysis of the data obtained from published sources and the survey reveal demand response and permanent load shifting opportunities by growing region, irrigation source, irrigation method, grower size, and utility coverage. The study examines some solutions for demand response and permanent load shifting in agricultural irrigation, which include adequate irrigation system capacity, automatic controls, variable frequency drives, and the contribution from energy efficiency measures. The study further examines the potential and challenges for grower acceptance of demand response and permanent load shifting in California agricultural irrigation. As part of the examination, the study considers to what extent permanent load shifting, which is already somewhat accepted within the agricultural sector, mitigates the need or benefit of demand response for agricultural irrigation. Recommendations for further study include studies on how to gain grower acceptance of demand response as well as other related studies such as conducting a more comprehensive survey of California growers.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Adaptively controlled fast production of defect-free beryllium ion crystals using pulsed laser ablation

Trapped atomic ions find wide applications ranging from precision measurement to quantum information science and quantum computing. Beryllium ions are widely used due to the light mass and convenient atomic structure of beryllium; however, conventional ion loading from thermal ovens exerts undesirable gas loads for a prolonged duration. Here, we demonstrate a method to rapidly produce pure linear chains of beryllium ions with pulsed laser ablation, serving as a starting point for large-scale quantum information processing. Our method is fast compared to thermal ovens, reduces the gas load to only 10 -12 Torr (10 -10 Pa) level, yields a short recovery time of a few seconds, and also eliminates the need for a deep ultraviolet laser for photoionization. We also study the loading dynamics, which show non-Poissonian statistics in the presence of sympathetic cooling. In addition, we apply feedback control to obtain defect-free ion chains with desirable lengths.

47 OTHER INSTRUMENTATION↗

Energy information systems (EIS): Technology costs, benefit, and best practice uses

Energy information systems are the web-based software, data acquisition hardware, and communication systems used to store, analyze, and display building energy data. They often include analysis methods such as baselining, benchmarking, load profiling, and energy anomaly detection. This report documents a large-scale assessment of energy information system (EIS) uses, costs, and energy benefits, based on a series of focused case study investigations that are synthesized into generalizable findings. The overall objective is to provide organizational decision makers with the information they need to make informed choices as to whether or not to invest in an EIS--a promising technology that can enable up to 20 percent site energy savings, quick payback, and persistent low-energy performance when implemented as part of best-practice energy management programs.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

IM3 + EPRI Data Center Load Projections

This dataset contains scenarios of hourly total electricity demand with and without projected loads from data centers over the period 2022-2040. The root projections without data center demands are identical to those documented in Burleyson et al. 2024. In short, those projections encompass hourly electricity demands for 54 Balancing Authorities (BAs) in the United States across a range of eight of weather and socioeconomic scenarios. Refer to the root dataset and accompanying publication, Burleyson et al. 2025, for information about how those projections were generated. For this derivative dataset we used the base loads from the following scenarios: rcp45hotter_ssp3 rcp45hotter_ssp5 rcp85hotter_ssp3 rcp85hotter_ssp5 The root load projections did not reflect the drastic expansion of data centers that has occurred in the last several years to support artificial intelligence and cloud computing. To reflect growth in data center demand, a second set of load projections were created in which we layered in additional data center load projections based on the data center load growth scenarios described in a 2024 report by the Electric Power Research Institute (EPRI): "Powering Intelligence: Analyzing Artificial Intelligence and Data Center Energy Consumption". The EPRI projections from the report are included in this dataset (EPRI_2024_Projections.xlsx). That report contained annual state-level data center load projections for four year-over-year growth rates for data center demands: Low (3.71% annual growth) Moderate (5% annual growth) High (10% annual growth) Higher (15% annual growth) To homogenize the load projections with and without data centers we had to get them to a common scale. The first step was to take the EPRI annual state-level data center energy consumption values and convert them to 8760-hr loads for each year. We did that by assuming a flat (e.g., not weather- or time-sensitive) load profile and distributing the data center loads in each state evenly across all hours in a year. From there the loads were downscaled from the state-level to the county-level using 2019 county-level populations as weights. Finally, the county-level hourly data center loads were summed to the BA-level using the county-to-BA mapping underpinning the root load projections. The net result is 16 (4 weather and socioeconomic scenarios crossed with 4 data center load growth scenarios) unique load projections for the period 2022-2040. The file format follows that of the root dataset with a single additional column "Scaled_TELL_BA_Load_with_DC_MWh" that contains the hourly loads with the added data center loads for a given BA-year-scenario combination. Please refer to the readme file in the root dataset for more information on the file format.

Burleyson, Casey [Pacific Northwest National Labor↗