Search NASA⌕ Search

SEARCH · Search NASA

Results for “interface failure”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Navigation in large information spaces represented as hypertext: A review of the literature

The problem addressed is the failure of information-space navigation tools when the space grows to large. The basic goal is to provide the power of the hypertext interface in such a way as to be most easily comprehensible to the user. It was determined that the optimal structure for information is an overlapping, simplified hierarchy. The hierarchical structure should be made obvious to the user, and many of the non-hierarchical links in the information space should either by eliminated, or should be de-emphasized so that the novice user is not confused by them. Only one of the hierarchies should be very simple.

Brown, Marcus↗

Programs Help Create And Evaluate Markov Models

Pade Approximation With Scaling (PAWS) and Scaled Taylor Exponential Matrix (STEM) computer programs provide flexible, user-friendly, language-based interface for creation and evaluation of Markov models describing behaviors of fault-tolerant reconfigurable computer systems. Produce exact solution for probabilities of system failures and provide conservative estimates of numbers of significant digits in solutions. Also offer as part of bundled package with SURE and ASSIST, two other reliable analysis programs developed by Systems Validation Methods group at Langley Research Center.

Butler, Ricky W.↗

Space Station module Power Management And Distribution (PMAD) system

This project consists of several tasks which are unified toward experimentally demonstrating the operation of a highly autonomous, user-supportive power management and distribution system for Space Station Freedom (SSF) habitation/laboratory modules. This goal will be extended to a demonstration of autonomous, cooperative power system operation for the whole SSF power system through a joint effort with NASA's Lewis Research Center, using their Autonomous Power System. Short term goals for the space station module power management and distribution include having an operational breadboard reflecting current plans for SSF, improving performance of the system communications, and improving the organization and mutability of the artificial intelligence (AI) systems. In the middle term, intermediate levels of autonomy will be added, user interfaces will be modified, and enhanced modeling capabilities will be integrated in the system. Long term goals involve conversion of all software into Ada, vigorous verification and validation efforts and, finally, seeing an impact of this research on the operation of SSF. Conversion of the system to a DC Star configuration is now in progress, and should be completed by the end of October, 1989. This configuration reflects the latest SSF module architecture. Hardware is now being procured which will improve system communications significantly. The Knowledge-Based Management System (KBMS) is initially developed and the rules from FRAMES have been implemented in the KBMS. Rules in the other two AI systems are also being grouped modularly, making them more tractable, and easier to eventually move into the KBMS. Adding an intermediate level of autonomy will require development of a planning utility, which will also be built using the KBMS. These changes will require having the user interface for the whole system available from one interface. An Enhanced Model will be developed, which will allow exercise of the system through the interface without requiring all of the power hardware to be operational. The functionality of the AI systems will continue to be advanced, including incipient failure detection. Ada conversion will begin with the lowest level processor (LLP) code. Then selected pieces of the higher level functionality will be recorded in Ada and, where possible, moved to the LLP level. Validation and verification will be done on the Ada code, and will complete sometimes after completion of the Ada conversion.

Walls, Bryan↗

Fault recovery in the reliable multicast protocol

The Reliable Multicast Protocol (RMP) provides a unique, group-based model for distributed programs that need to handle reconfiguration events at the application layer. This model, called membership views, provides an abstraction in which events such as site failures, network partitions, and normal join-leave events are viewed as group reformations. RMP provides access to this model through an application programming interface (API) that notifies an application when a group is reformed as the result of a some event. RMP provides applications with reliable delivery of messages using an underlying IP Multicast (12, 5) media to other group members in a distributed environment even in the case of reformations. A distributed application can use various Quality of Service (QoS) levels provided by RMP to tolerate group reformations. This paper explores the implementation details of the mechanisms in RMP that provide distributed applications with membership view information and fault recovery capabilities.

Callahan, John R.↗

Specification and Design of a Fault Recovery Model for the Reliable Multicast Protocol

The Reliable Multicast Protocol (RMP) provides a unique, group-based model for distributed programs that need to handle reconfiguration events at the application layer. This model, called membership views, provides an abstraction in which events such as site failures, network partitions, and normal join-leave events are viewed as group reformations. RMP provides access to this model through an application programming interface (API) that notifies an application when a group is reformed as the result of a some event. RMP provides applications with reliable delivery of messages using an underlying IP Multicast media to other group members in a distributed environment even in the case of reformations. A distributed application can use various Quality of Service (QoS) levels provided by RMP to tolerate group reformations. This paper explores the implementation details of the mechanisms in RMP that provide distributed applications with membership view information and fault recovery capabilities.

Montgomery, Todd↗

Progressive Damage Analyses of Skin/Stringer Debonding

The debonding of skin/stringer constructions is analyzed using a step-by-step simulation of material degradation based on strain softening decohesion elements and a ply degradation procedure. Decohesion elements with mixed-mode capability are placed at the interface between the skin and the flange to simulate the initiation and propagation of the delamination. In addition, the initiation and accumulation of fiber failure and matrix damage is modeled using Hashin-type failure criteria and their corresponding material degradation schedules. The debonding predictions using simplified three-dimensional models correlate well with test results.

Daville, Carlos G.↗

Performance of High Temperature Operational Amplifier, Type LM2904WH, under Extreme Temperatures

Operation of electronic parts and circuits under extreme temperatures is anticipated in NASA space exploration missions as well as terrestrial applications. Exposure of electronics to extreme temperatures and wide-range thermal swings greatly affects their performance via induced changes in the semiconductor material properties, packaging and interconnects, or due to incompatibility issues between interfaces that result from thermal expansion/contraction mismatch. Electronics that are designed to withstand operation and perform efficiently in extreme temperatures would mitigate risks for failure due to thermal stresses and, therefore, improve system reliability. In addition, they contribute to reducing system size and weight, simplifying its design, and reducing development cost through the elimination of otherwise required thermal control elements for proper ambient operation. A large DC voltage gain (100 dB) operational amplifier with a maximum junction temperature of 150 C was recently introduced by STMicroelectronics [1]. This LM2904WH chip comes in a plastic package and is designed specifically for automotive and industrial control systems. It operates from a single power supply over a wide range of voltages, and it consists of two independent, high gain, internally frequency compensated operational amplifiers. Table I shows some of the device manufacturer s specifications.

Patterson, Richard↗

Space Suit Portable Life Support System Fastener and Insert Summary, Issues, and Testing Results

Fasteners are included in every assembly on the Exploration External Mobility Unity Portable Life Support System (xEMU PLSS). However, fasteners and inserts have been the cause of many issues seen on the PLSS during development; furthermore, inserts with thermoplastics are not very well understood. The materials used in the PLSS are sometimes softer and lighter weight metals or thermoplastics which require the installation of inserts to improve the interface strength. In addition, space flight requirements call out the need for an additional running/locking torque, so they do not detach in case of failure of the final torque. The xEMU PLSS has experienced various issues with fasteners and inserts, from the bolt binding in an insert or the running torque failing prematurely. A study has been completed to address the running torque life problem. This study compares the insert and locking feature combinations to determine the combination which maximizes life. The study found that using a locking patch with an insert fails after the first installation. Therefore, it is no longer recommended to use a locking patch fastener with an insert for future installments. For the bolt binding issue, inserts have been installed too deep and have caused the bolt to bind near the final threads of the inserts where the hole is not tapped deep enough. Thermoplastics, on the other end, can either use standard helical inserts or heat set inserts. Another study was performed using tangless inserts and heat inserts installed in thermoplastics to quantify the expected pull-out strength for various insert installation parameters (insert type, temperature, and pressure). This paper will review the issues and lessons learned with fasteners on the xEMU PLSS, provide results of a locking feature study, and provide results and recommended installation settings from a heat insert study.

Ryan Ogilvie↗

Advanced Technologies for Future Spacecraft Cockpits and Space-based Control Centers

The National Aeronautics and Space Administration (NASA) is embarking on a new era of Space Exploration, aimed at sending crewed spacecraft beyond Low Earth Orbit (LEO), in medium and long duration missions to the Lunar surface, Mars and beyond. The challenges of such missions are significant and will require new technologies and paradigms in vehicle design and mission operations. Current roles and responsibilities of spacecraft systems, crew and the flight control team, for example, may not be sustainable when real-time support is not assured due to distance-induced communication lags, radio blackouts, equipment failures, or other unexpected factors. Therefore, technologies and applications that enable greater Systems and Mission Management capabilities on-board the space-based system will be necessary to reduce the dependency on real-time critical Earth-based support. The focus of this paper is in such technologies that will be required to bring advance Systems and Mission Management capabilities to space-based environments where the crew will be required to manage both the systems performance and mission execution without dependence on the ground. We refer to this concept as autonomy. Environments that require high levels of autonomy include the cockpits of future spacecraft such as the Mars Exploration Vehicle, and space-based control centers such as a Lunar Base Command and Control Center. Furthermore, this paper will evaluate the requirements, available technology, and roadmap to enable full operational implementation of onboard System Health Management, Mission Planning/re-planning, Autonomous Task/Command Execution, and Human Computer Interface applications. The technology topics covered by the paper include enabling technology to perform Intelligent Caution and Warning, where the systems provides directly actionable data for human understanding and response to failures, task automation applications that automate nominal and Off-nominal task execution based on human input or integrated health state-derived conditions. Shifting from Systems to Mission Management functions, we discuss the role of automated planning applications (tactical planning) on-board, which receive data from the other cockpit automation systems and evaluate the mission plan against the dynamic systems and mission states and events, to provide the crew with capabilities that enable them to understand, change, and manage the timeline of their mission. Lastly, we discuss the role of advanced human interface technologies that organize and provide the system md mission information to the crew in ways that maximize their situational awareness and ability to provide oversight and control of aLl the automated data and functions.

Garcia-Galan, Carlos↗

Validated Reactive Force Field Quantifies MXene Interfacial Properties, Mechanics, and Thermal Transport

MXenes combine rich surface chemistry, mechanical strength, and high conductivity for a multitude of emerging applications. Predictive modeling supports accelerated materials designs and has been limited by the absence of validated and transferable force fields. Here, we introduce an interpretable, reactive INTERFACE force field (IFF and IFF-R) for Ti 3 C 2 T x MXenes that is trained based on chemical knowledge and achieves quantitative agreement with experiments across lattice parameters (<0.5%), density (<0.2%), liquid contact angles, Raman spectra, and the in-plane elastic modulus (∼320 GPa). The models cover surface terminations from hydroxyl (−OH) to fluorine (−F) groups and are extensible to other chemistries. We introduce pH-resolved surface chemistry and identify dopamine adsorption mechanisms at MXene–aqueous interfaces supported by QCM-D and UV–Vis experiments. The data reveal coplanar and perpendicular binding modes and concentration-dependent multilayer assembly. We predict previously inaccessible properties, including termination-dependent cleavage energies, interlayer shear moduli and dynamic shear failure, nanoindentation and brittle fracture, anisotropic in-plane and out-of-plane thermal conductivities, including the role of defects. Agreement with available experimental data is consistently close and exceeds DFT accuracy across the benchmark properties examined. The IFF/IFF-R model is compatible with CHARMM, AMBER, OPLS, and CVFF force fields for simulations of MXenes with diverse surface terminations, electrolyte interfaces, biointerfaces, and polymer composites without additional parameters. Parameter sets, 3D models, and analysis scripts are provided for community use. The validated, reactive, and transferable IFF framework facilitates predictive design of MXene-based films, membranes, sensing interfaces, and composites.

MXene↗

Single fiber peel test to assess ultra high molecular weight polyethylene fiber mesostructure interactions

ABSTRACT In this work, a variable angle, single fiber peel test is developed to analyze the effects of fiber structure on the mixed mode failure within ultra high molecular weight polyethylene fibers. The Mode I and Mode II peel energy release rates are quantified and the effects of fiber meso/nanostructure on these modes are examined. Comparison of the load‐extension curves from the peel test with in‐situ video, and post‐mortem analysis using high‐resolution microscopy techniques indicates that Mode I and Mode II splitting are both significantly influenced by the deformation of nanoscale fibrils within a mesoscale network. The fibrils in the network are placed in tension across the peel/shear interface resulting in elevated values of peel energy release rates with an increasing number of engaged fibrils. The number of engaged fibrils is shown to increase with decreasing peel angle and increasing Mode II failure contribution. A bi‐linear mixed‐mode failure criterion is established. The results, and analysis of the fiber structure are discussed in context of their implications for load pathways in the fiber. © 2018 Wiley Periodicals, Inc. J. Appl. Polym. Sci. 2018 , 135 , 46156.

McDaniel, Preston B.↗

Interface Characterization within a Nuclear Fuel Plate

To predict the performance of nuclear fuels and materials, irradiated fuel plates must be characterized efficiently and accurately in highly radioactive environments. The characterization must take place remotely and work in settings largely inhospitable to modern digital instrumentation. Characterization techniques based on non-contacting laser sensing methods enable remote operation in a robust manner within a hot-cell environment. Laser characterization instrumentation can offer high spatial resolution and remain effective for scanning large areas. A laser shock (LS) system is currently being developed as a post-irradiation examination (PIE) technique in the hot fuel examination facility (HFEF) at the Idaho National Laboratory (INL). The laser shock technique will characterize material properties and failure loads/mechanisms in various composite components and materials such as plate fuel and next-generation fuel forms in high radiation areas. The laser shock-technique induces large amplitude shock waves to mechanically characterize interfaces such as the fuel–clad bond. As part of the laser shock system, a laser-based ultrasonic C-scan system will be used to detect and characterize debonding caused by the application of the laser shock. The laser shock system has been used to characterize the resulting bond strength within plate fuels which have been fabricated using different fabrication processes. The results of this study will be to select the fabrication process that provides the strongest interface.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Comparison of Nb 3 Sn Insulation Systems With as Received and De-Sized Glass

Epoxy cracking has been the main suspected contributor to training in Nb 3 Sn magnets for some time, as it leads to energy release and magnet quenching. Cracking in a superconducting composite can occur from several modes, and the likelihood of these modes is not well understood. Failure has been observed between insulation systems and the superconducting cable itself rather than within the cable or insulation. To target the behavior at the interface, samples have been fabricated and tested for Mode I fracture toughness in an adapted version of ASTM D5528. This work seeks to better characterize the fracture toughness of this interface to better understand how to model and design insulation systems.

Krave, Steven T. [Fermilab] (ORCID:000000021752145↗

Interlaminar Fracture Toughness Testing of Nb3Sn Insulation Systems

Epoxy cracking has been the main suspected contributor to training in Nb3Sn magnets for some time, as it leads to energy release and magnet quenching. Cracking in a superconducting composite can occur from several modes, and the likelihood of these modes is not well understood. Failure has been observed between insulation systems and the superconducting cable itself rather than within the cable or insulation. To target the behavior at the interface, samples have been fabricated and tested for mode I fracture toughness in an adapted version of ASTM D5528. This work seeks to better characterize the fracture toughness of this interface to better understand how to model and design insulation systems.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A model for a space shuttle safing and failure-detection expert

The safing and failure-detection expert (SAFE) is a prototype for a malfunction detection, diagnosis, and safing system for the atmospheric revitalization subsystem (ARS) in the Space Shuttle orbiter. SAFE, whose knowledge was extracted from expert-provided heuristics and documented procedures, automatically manages all phases of failure handling: detection, diagnosis, testing procedures, and recovery instructions. The SAFE architecture allows it to handle correctly sensor failures and multiple malfunctions. Since SAFE is highly interactive, it was used as a test bed for the evaluation of various advanced human-computer interface (HCI) techniques. The use of such expert systems in the next generation of space vehicles would increase their reliability and autonomy to levels not achievable before.

Zeilingold, Daphna↗

ACARA user's manual

ACARA (Availability, Cost, and Resource Allocation) is a computer program which analyzes system availability, lifecycle cost (LCC), and resupply scheduling using Monte Carlo analysis to simulate component failure and replacement. This manual was written to: (1) explain how to prepare and enter input data for use in ACARA; (2) explain the user interface, menus, input screens, and input tables; (3) explain the algorithms used in the program; and (4) explain each table and chart in the output.

Stalnaker, Dale K.↗

Design/Analysis of Metal/Composite Bonded Joints for Survivability at Cryogenic Temperatures

A major design and analysis challenge for the JWST ISM structure is the metal/composite bonded joints that will be required to survive down to an operational ultra-low temperature of 30K (-405 F). The initial and current baseline design for the plug-type joint consists of a titanium thin walled fitting (1-3mm thick) bonded to the interior surface of an M555/954-6 composite truss square tube with an axially stiff biased lay-up. Metallic fittings are required at various nodes of the truss structure to accommodate instrument and lift-point bolted interfaces. Analytical experience and design work done on metal/composite bonded joints at temperatures below liquid nitrogen are limited and important analysis tools, material properties, and failure criteria for composites at cryogenic temperatures are virtually nonexistent. Increasing the challenge is the difficulty in testing for these required tools and parameters at 30K. A preliminary finite element analysis shows that failure due to CTE mismatch between the biased composite and titanium or aluminum is likely. Failure is less likely with Invar, however an initial mass estimate of Invar fittings demonstrates that Invar is not an automatic alternative. In order to gain confidence in analyzing and designing the ISM joints, a comprehensive joint development testing program has been planned and is currently running. The test program is designed for the correlation of the analysis methodology, including tuning finite element model parameters, and developing a composite failure criterion for the effect of multi-axial composite stresses on the strength of a bonded joint at 30K. The testing program will also consider stress mitigation using compliant composite layers and potential strength degradation due to multiple thermal cycles. Not only will the finite element analysis be correlated to the test data, but the FEA will be used to guide the design of the test. The first phase of the test program has been completed and the preliminary analysis has been revisited based on the test data In this work, we present an overview of the test plan, results today, and resulting design improvements.

Bartoszyk, Andrew E.↗

Thermostructural Evaluation of Joggle Region on the Shuttle Orbiter's Wing Leading Edge

An investigation was initiated to determine the cause of coating spallation occurring on the Shuttle Orbiter's wing leading edge panels in the slip-side joggle region. The coating spallation events were observed, post flight, on differing panels on different missions. As part of the investigation, the high re-entry heating occurring on the joggles was considered here as a possible cause. Thus, a thermostructural evaluation was conducted to determine the detailed state-of-stress in the joggle region during re-entry and the feasibility of a laboratory test on a local joggle specimen to replicate this state-of-stress. A detailed three-dimensional finite element model of a panel slip-side joggle region was developed. Parametric and sensitivity studies revealed significant stresses occur in the joggle during peak heating. A critical interlaminar normal stress concentration was predicted in the substrate at the coating interface and was confined to the curved joggle region. Specifically, the high interlaminar normal stress is identified to be the cause for the occurrence of failure in the form of local subsurface material separation occurring in the slip-side joggle. The predicted critical stresses are coincident with material separations that had been observed with microscopy in joggle specimens obtained from flight panels.

Walker, Sandra P.↗