LANL Experimental and modeling studies to explore the feasibility of CO2-EOR/storage in unconventional reservoirs
Explore the source record for details and available documents.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Abstract not provided.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Modeling and correlation studies of solar cells was discussed. Recursive relationships were used to generate solutions at a number of mesh points within the emitter region. Photoexcited hole concentration and built-in electric field were calculated as a function of position. Simulated and experimentally determined I-V curves were shown to have good fit.
Nowadays, buildings are expected to offer demand side services to the power grid to enhance the electrical load flexibility, which leads to the concepts of grid-interactive efficient buildings (GEBs). Phase change material (PCM)-based thermal energy storage has seen increasing attention in recent years for peak load shifting of grid-interactive efficient buildings (GEBs). Numerical models are critical tools for design and evaluation of PCM-integrated systems. Most industrial-grade PCMs are reported to melt/freeze over a temperature range instead of at a unique temperature. Such thermal hysteresis effect significantly affects the reliability of simulation results because not only the heat transfer process depends on melting and freezing temperatures, the PCM thermal properties change significantly during the phase change process as well. This study is aimed to develop a model for the PCMs used in the building envelope with the capability to accurately simulate hysteretic behaviors. Further, this model is based on a two-phase assumption and is implemented in a whole building energy performance simulation program (i.e., EnergyPlus). A comparison between numerical results and experimental data shows that during a complete phase transition, the two-phase model could achieve a good agreement with the experimental data. During a partial phase transition, the two-phase model could lead to significant improvements compared to other alternative PCM models, including the existing PCM model in EnergyPlus. Last, whole building simulations were performed to study this model's performance regarding heating/cooling loads and zone mean air temperature of a given building. The results show that the difference in hourly heating/cooling loads introduced by the models was less than 1% in design conditions, while significant changes were observed in both hourly heating/cooling loads and zone mean air temperature when the PCM envelope underwent partial phase transition processes.
Turbulence Model Verification study for the Fourth High Lift Prediction Workshop to be held at Aviation 2021
Microphysical processes in deep convective clouds are sensitive to the number concentrations of cloud condensation nuclei (CCN) and ice nucleating particles (INPs), but the effects of INPs are less studied. Modeling studies investigating the effects of INPs and/or CCN on deep convection typically retain a volume‐dependent raindrop freezing relation. The resulting neglect of aerosol accumulation in raindrops via drop collisions has likely produced unrealistic storm responses to INPs in past studies. To address this deficiency, a new immersion freezing algorithm was developed and embedded in a bulk microphysics scheme that freezes both cloud drops and raindrops using the same immersion freezing INP (IF‐INP) activity spectrum based on measurements. Multiple idealized simulations of a single case of deep convection observed during the Clouds, Aerosols, and Complex Terrain Interactions (CACTI) field campaign were conducted, with microphysical differences produced by independently altering IF‐INP temperature dependencies and CCN number concentrations from their observed values. Surface precipitation in all simulations resulted almost exclusively from riming graupel that melted upon descending to the surface. Rainfall and cold pools were substantially and systematically weakened with increased CCN due to decreased graupel riming rates but were relatively insensitive to variations in the magnitude and slope of IF‐INP spectra due to compensating depletion of supercooled liquid water. These compensating processes were a consequence of the accumulation of IF‐INPs in raindrops, encouraging caution in studying IF‐INP effects upon thunderstorms using traditional volume‐dependent drop freezing relationships.
Models designed to support the hydrologic studies associated with urban water resources planning require input parameters that are defined in terms of land cover. Estimating the land cover is a difficult and expensive task when drainage areas larger than a few sq. km are involved. Conventional and LANDSAT based methods for estimating the land cover based input parameters required by hydrologic planning models were compared in a case study of the 50.5 sq. km (19.5 sq. mi) Four Mile Run Watershed in Virginia. Results of the study indicate that the LANDSAT based approach is highly cost effective for planning model studies. The conventional approach to define inputs was based on 1:3600 aerial photos, required 110 man-days and a total cost of $14,000. The LANDSAT based approach required 6.9 man-days and cost $2,350. The conventional and LANDSAT based models gave similar results relative to discharges and estimated annual damages expected from no flood control, channelization, and detention storage alternatives.
Guideline for the construction of security constrained economic dispatch models for use in NETL studies.
We present the model-independent studies of non attractor inflation in the context of effective field theory (EFT) of inflation. Within the EFT approach two independent branches of non-attractor inflation solutions are discovered in which a near scale-invariant curvature perturbation power spectrum is generated from the interplay between the variation of sound speed and the second slow roll parameter η. The first branch captures and extends the previously studied models of non-attractor inflation in which the curvature perturbation is not frozen on super-horizon scales and the single field non-Gaussianity consistency condition is violated. We present the general expression for the amplitude of local-type non-Gaussianity in this branch. The second branch is new in which the curvature perturbation is frozen on super-horizon scales and the single field non-Gaussianity consistency condition does hold in the squeezed limit. Depending on the model parameters, the shape of bispectrum in this branch changes from an equilateral configuration to a folded configuration while the amplitude of non-Gaussianity is less than unity.
We study the impact of fuel prices, technology innovation, and a CO2 emissions reduction policy on both the electric power and end-use sectors by comparing outputs from four U.S. energy-economic models through the year 2050. Achieving innovation goals decreases CO2 emissions in all models, regardless of natural gas price, due to increased energy efficiency and low-carbon generation becoming more cost competitive. For the models that include domestic natural gas markets, achieving innovation goals lowers wholesale electricity prices, but this effect diminishes as projected natural gas prices increase. Higher natural gas prices lead to higher wholesale electricity prices but fewer coal capacity retirements. A CO2 electric power sector emissions cap influences electric sector evolution under reference technology assumptions but has little to no incremental influence when added to innovation goals. Long-term, meeting innovation goals achieves a generation mix with similar CO2 emissions compared to the CO2 policy but with smaller increases to wholesale electricity prices. In the short-term, the relative effect on wholesale prices differs by model. Finally, higher natural gas prices, achieving innovation goals, and the combination of the two, increases the amount of renewable generation that is cost-effective to build and operate while slowing the growth of natural-gas fired generation, which is the predominant generation type in 2050 under reference conditions.
Nudging as an assimilation technique has seen increased use in recent years in the development and evaluation of climate models. Constraining the simulated wind and temperature fields using global weather reanalysis facilitates more straightforward comparison between simulation and observation, and reduces uncertainties associated with natural variabilities of the large-scale circulation. On the other hand, the forcing introduced by nudging can be strong enough to change the basic characteristics of the model climate. In the paper we show that for the Community Atmosphere Model version 5 (CAM5), due to the systematic temperature bias in the standard model and the sensitivity of simulated ice formation to anthropogenic aerosol concentration, nudging towards reanalysis results in substantial reductions in the ice cloud amount and the impact of anthropogenic aerosols on long-wave cloud forcing. In order to reduce discrepancies between the nudged and unconstrained simulations, and meanwhile take the advantages of nudging, two alternative experimentation methods are evaluated. The first one constrains only the horizontal winds. The second method nudges both winds and temperature, but replaces the long-term climatology of the reanalysis by that of the model. Results show that both methods lead to substantially improved agreement with the free-running model in terms of the top-of-atmosphere radiation budget and cloud ice amount. The wind-only nudging is more convenient to apply, and provides higher correlations of the wind fields, geopotential height and specific humidity between simulation and reanalysis. Results from both CAM5 and a second aerosol–climate model ECHAM6-HAM2 also indicate that compared to the wind-and-temperature nudging, constraining only winds leads to better agreement with the free-running model in terms of the estimated shortwave cloud forcing and the simulated convective activities. This suggests nudging the horizontal winds but not temperature is a good strategy for the investigation of aerosol indirect effects since it provides well-constrained meteorology without strongly perturbing the model's mean climate.
System modeling is critical when studying operation faults in chiller plants and boiler plants. However, current fault models have difficulties faithfully representing the operation of chiller plants and boiler plants under the effects of those faults, especially the control-related ones. In this study, we present a systematic method to develop high-fidelity models for approximating the behaviors of chiller plants and boiler plants under faulty conditions. Compared to existing ones, the resulting fault models have two advantages: first, they better characterize the dynamic patterns in the system operation. In those models, control architecture and control logic are faithfully implemented. Thus, they can be used to study control-related faults, such as incorrect staging control due to sensor bias and mistuned feedback control. Second, they are readily extensible and can support large-scale investigations to explore different faulty conditions/scenarios. Those models are established in a hierarchical structure while modules in each layer can be redeclared and parameterized at upper layers. In such a case, modifications to the models can be realized through model modifiers and the process can be easily streamlined with scripts. We applied the proposed models in a comprehensive fault impact evaluation of the 13 control-related faults of chiller and boiler plants. In this evaluation, the proposed plant model is coupled with the EnergyPlus thermal load model to study the impact of various faulty scenarios. Based on the evaluation results, we identified the faults that have the most significant impacts on the operation of the chiller and boiler plants, respectively. We also found that the relationship between the impacts of the studied faults and the severity level of the faults are highly non-linear