Search NASA⌕ Search

SEARCH · Search NASA

Results for “multimodal data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Comparison of prone versus supine 18F-FDG-PET of locally advanced breast cancer: Phantom and preliminary clinical studies

Purpose: Previous studies have demonstrated how imaging of the breast with patients lying prone using a supportive positioning device markedly facilitates longitudinal and/or multimodal image registration. In this contribution, the authors’ primary objective was to determine if there are differences in the standardized uptake value (SUV) derived from [{sup 18}F]fluorodeoxyglucose (18F-FDG) positron emission tomography (PET) in breast tumors imaged in the standard supine position and in the prone position using a specialized positioning device. Methods: A custom positioning device was constructed to allow for breast scanning in the prone position. Rigid and nonrigid phantom studies evaluated differences in prone and supine PET. Clinical studies comprised 18F-FDG-PET of 34 patients with locally advanced breast cancer imaged in the prone position (with the custom support) followed by imaging in the supine position (without the support). Mean and maximum values (SUV{sub peak} and SUV{sub max}, respectively) were obtained from tumor regions-of-interest for both positions. Prone and supine SUV were linearly corrected to account for the differences in 18F-FDG uptake time. Correlation, Bland–Altman, and nonparametric analyses were performed on uptake time-corrected and uncorrected data. Results: SUV from the rigid PET breast phantom imaged in the prone position with the support device was 1.9% lower than without the support device. In the nonrigid PET breast phantom, prone SUV with the support device was 5.0% lower than supine SUV without the support device. In patients, the median (range) difference in uptake time between prone and supine scans was 16.4 min (13.4–30.9 min), which was significantly—but not completely—reduced by the linear correction method. SUV{sub peak} and SUV{sub max} from prone versus supine scans were highly correlated, with concordance correlation coefficients of 0.91 and 0.90, respectively. Prone SUV{sub peak} and SUV{sub max} were significantly lower than supine in both original and uptake time-adjusted data across a range of index times (P < < 0.0001, Wilcoxon signed rank test). Before correcting for uptake time differences, Bland–Altman analyses revealed proportional bias between prone and supine measurements (SUV{sub peak} and SUV{sub max}) that increased with higher levels of FDG uptake. After uptake time correction, this bias was significantly reduced (P < 0.01). Significant prone-supine differences, with regard to the spatial distribution of lesions relative to isocenter, were observed between the two scan positions, but this was poorly correlated with the residual (uptake time-corrected) prone-supine SUV{sub peak} difference (P = 0.78). Conclusions: Quantitative 18F-FDG-PET/CT of the breast in the prone position is not deleteriously affected by the support device but yields SUV that is consistently lower than those obtained in the standard supine position. SUV differences between scans arising from FDG uptake time differences can be substantially reduced, but not removed entirely, with the current correction method. SUV from the two scan orientations is quantitatively different and should not be assumed equivalent or interchangeable within the same subject. These findings have clinical relevance in that they underscore the importance of patient positioning while scanning as a clinical variable that must be accounted for with longitudinal PET measurement, for example, in the assessment of treatment response.

60 APPLIED LIFE SCIENCES↗

SANE: strategic autonomous non-smooth exploration for multiple optima discovery in multi-modal and non-differentiable black-box functions

Both computational and experimental material discovery bring forth the challenge of exploring multidimensional and multimodal parameter spaces, such as phase diagrams of Hamiltonians with multiple interactions, composition spaces of combinatorial libraries, material structure image spaces, and molecular embedding spaces. Often these systems are black-boxes and time-consuming to evaluate, which resulted in strong interest towards active learning methods such as Bayesian optimization (BO). However, these systems are often noisy which make the black box function severely multi-modal and non-differentiable, where a vanilla BO can get overly focused near a single or faux optimum, deviating from the broader goal of scientific discovery. To address these limitations, here we developed Strategic Autonomous Non-Smooth Exploration (SANE) to facilitate an intelligent Bayesian optimized navigation with a proposed cost-driven probabilistic acquisition function to find multiple global and local optimal regions, avoiding the tendency to becoming trapped in a single optimum. To distinguish between a true and false optimal region due to noisy experimental measurements, a human (domain) knowledge driven dynamic surrogate gate is integrated with SANE. We implemented the gate-SANE into pre-acquired piezoresponse spectroscopy data of a ferroelectric combinatorial library with high noise levels in specific regions, and piezoresponse force microscopy (PFM) hyperspectral data. SANE demonstrated better performance than classical BO to facilitate the exploration of multiple optimal regions and thereby prioritized learning with higher coverage of scientific values in autonomous experiments. Our work showcases the potential application of this method to real-world experiments, where such combined strategic and human intervening approaches can be critical to unlocking new discoveries in autonomous research.

Biswas, Arpan [University of Tennessee, Knoxville,↗

Integrated adaptive optics optical coherence tomography and adaptive optics scanning laser ophthalmoscope system for simultaneous cellular resolution in vivo retinal imaging

We describe an ultrahigh-resolution (UHR) retinal imaging system that combines adaptive optics Fourier-domain optical coherence tomography (AO-OCT) with an adaptive optics scanning laser ophthalmoscope (AO-SLO) to allow simultaneous data acquisition by the two modalities. The AO-SLO subsystem was integrated into the previously described AO-UHR OCT instrument with minimal changes to the latter. This was done in order to ensure optimal performance and image quality of the AO- UHR OCT. In this design both imaging modalities share most of the optical components including a common AO-subsystem and vertical scanner. One of the benefits of combining Fd-OCT with SLO includes automatic co-registration between two acquisition channels for direct comparison between retinal structures imaged by both modalities (e.g., photoreceptor mosaics or microvasculature maps). Because of differences in the detection scheme of the two systems, this dual imaging modality instrument can provide insight into retinal morphology and potentially function, that could not be accessed easily by a single system. In this paper we describe details of the components and parameters of the combined instrument, including incorporation of a novel membrane magnetic deformable mirror with increased stroke and actuator count used as a single wavefront corrector. We also discuss laser safety calculations for this multimodal system. Finally, retinal images acquired in vivo with this system are presented.

59 BASIC BIOLOGICAL SCIENCES↗

Multimodal fission from self-consistent calculations

When multiple fission modes coexist in a given nucleus, distinct fragment yield distributions appear. Multimodal fission has been observed in a number of fissioning nuclei spanning the nuclear chart, and this phenomenon is expected to affect the nuclear abundances synthesized during the rapid neutron-capture process (𝑟-process). In this study, we generalize the previously proposed hybrid model for fission-fragment yield distributions to predict competing fission modes and estimate the resulting yield distributions. Here, our framework allows for a comprehensive large-scale calculation of fission-fragment yields suited for 𝑟-process nuclear network studies. Nuclear density functional theory is employed to obtain the potential energy and collective inertia tensor on a multidimensional collective space defined by mass multipole moments. Fission pathways and their relative probabilities are determined using the nudged elastic band method. Based on this information, mass and charge fission yields are predicted using the recently developed hybrid model. Fission properties of fermium isotopes are calculated in the axial quadrupole-octupole collective space for three energy density functionals (EDFs). Disagreement between the EDFs appears when multiple fission modes are present. Within our framework, the UNEDF⁢1 HFB EDF agrees best with experimental data. Calculations in the axial quadrupole-octupole-hexadecapole collective space improve the agreement with the experiment for SkM*. We also discuss the sensitivity of fission predictions on the choice of EDF for several superheavy nuclei. Fission-fragment yield predictions for nuclei with multiple fission modes are sensitive to the underlying EDF. For large-scale calculations in which a minimal number of collective coordinates is considered, UNEDF⁢1 HFB provides the best description of experimental data, though the sensitivity motivates robust quantification of the uncertainties of the theoretical model.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Capturing Travel Mode Adoption in Designing On-Demand Multimodal Transit Systems

This paper studies how to integrate rider mode preferences into the design of on-demand multimodal transit systems (ODMTSs). It is motivated by a common worry in transit agencies that an ODMTS may be poorly designed if the latent demand, that is, new riders adopting the system, is not captured. This paper proposes a bilevel optimization model to address this challenge, in which the leader problem determines the ODMTS design, and the follower problems identify the most cost efficient and convenient route for riders under the chosen design. The leader model contains a choice model for every potential rider that determines whether the rider adopts the ODMTS given her proposed route. To solve the bilevel optimization model, the paper proposes an exact decomposition method that includes Benders optimal cuts and no-good cuts to ensure the consistency of the rider choices in the leader and follower problems. Moreover, to improve computational efficiency, the paper proposes upper and lower bounds on trip durations for the follower problems, valid inequalities that strengthen the no-good cuts, and approaches to reduce the problem size with problem-specific preprocessing techniques. The proposed method is validated using an extensive computational study on a real data set from the Ann Arbor Area Transportation Authority, the transit agency for the broader Ann Arbor and Ypsilanti region in Michigan. The study considers the impact of a number of factors, including the price of on-demand shuttles, the number of hubs, and access to transit systems criteria. The designed ODMTSs feature high adoption rates and significantly shorter trip durations compared with the existing transit system and highlight the benefits of ensuring access for low-income riders. Finally, the computational study demonstrates the efficiency of the decomposition method for the case study and the benefits of computational enhancements that improve the baseline method by several orders of magnitude. Funding: This research was partly supported by National Science Foundation [Leap HI Proposal NSF-1854684] and the Department of Energy [Research Award 7F-30154].

Operations Research & Management Science↗

Multimodality instrument for tissue characterization

A system with multimodality instrument for tissue identification includes a computer-controlled motor driven heuristic probe with a multisensory tip. For neurosurgical applications, the instrument is mounted on a stereotactic frame for the probe to penetrate the brain in a precisely controlled fashion. The resistance of the brain tissue being penetrated is continually monitored by a miniaturized strain gauge attached to the probe tip. Other modality sensors may be mounted near the probe tip to provide real-time tissue characterizations and the ability to detect the proximity of blood vessels, thus eliminating errors normally associated with registration of pre-operative scans, tissue swelling, elastic tissue deformation, human judgement, etc., and rendering surgical procedures safer, more accurate, and efficient. A neural network program adaptively learns the information on resistance and other characteristic features of normal brain tissue during the surgery and provides near real-time modeling. A fuzzy logic interface to the neural network program incorporates expert medical knowledge in the learning process. Identification of abnormal brain tissue is determined by the detection of change and comparison with previously learned models of abnormal brain tissues. The operation of the instrument is controlled through a user friendly graphical interface. Patient data is presented in a 3D stereographics display. Acoustic feedback of selected information may optionally be provided. Upon detection of the close proximity to blood vessels or abnormal brain tissue, the computer-controlled motor immediately stops probe penetration. The use of this system will make surgical procedures safer, more accurate, and more efficient. Other applications of this system include the detection, prognosis and treatment of breast cancer, prostate cancer, spinal diseases, and use in general exploratory surgery.

Mah, Robert W.↗

Multimodality Instrument for Tissue Characterization

A system with multimodality instrument for tissue identification includes a computer-controlled motor driven heuristic probe with a multisensory tip is discussed. For neurosurgical applications, the instrument is mounted on a stereotactic frame for the probe to penetrate the brain in a precisely controlled fashion. The resistance of the brain tissue being penetrated is continually monitored by a miniaturized strain gauge attached to the probe tip. Other modality sensors may be mounted near the probe tip to provide real-time tissue characterizations and the ability to detect the proximity of blood vessels, thus eliminating errors normally associated with registration of pre-operative scans, tissue swelling, elastic tissue deformation, human judgement, etc., and rendering surgical procedures safer, more accurate, and efficient. A neural network, program adaptively learns the information on resistance and other characteristic features of normal brain tissue during the surgery and provides near real-time modeling. A fuzzy logic interface to the neural network program incorporates expert medical knowledge in the learning process. Identification of abnormal brain tissue is determined by the detection of change and comparison with previously learned models of abnormal brain tissues. The operation of the instrument is controlled through a user friendly graphical interface. Patient data is presented in a 3D stereographics display. Acoustic feedback of selected information may optionally be provided. Upon detection of the close proximity to blood vessels or abnormal brain tissue, the computer-controlled motor immediately stops probe penetration.

Mah, Robert W.↗

Radioactive EGFR Antibody Cetuximab in Multimodal Cancer Treatment: Stability and Synergistic Effects With Radiotherapy

Purpose: Systemic therapies when added to whole brain radiotherapy have failed to improve the survival of patients with multiple brain metastases. The epidermal growth factor receptor antibody cetuximab is an attractive option, if it is able to cross the blood-brain barrier. This might be proven with molecular imaging if the radiolabeled antibody is stable long enough to be effective. This study investigated the stability of radiolabeled cetuximab (Erbitux) ({sup 131}I-Erbi) and potential synergistic effects with radiotherapy in vitro. Methods and Materials: Two cell lines were investigated, A431 with numerous epidermal growth factor receptors, and JIMT without epidermal growth factor receptors. We labeled 0.4 mg cetuximab with 50 MBq of [{sup 131}I] iodide. Stability was determined for 72 h. The cell cultures were incubated with {sup 131}I-Erbi or cold cetuximab for 72 h. Uptake and cell proliferation were measured every 24 h after no radiotherapy or irradiation with 2, 4, or 10 Gy. Results: The radiolabeling yield of {sup 131}I-Erbi was always >80%. The radiochemical purity was still 93.6% after 72 h. A431 cells showed a {sup 131}I-Erbi uptake about 100-fold greater than the JIMT controls. After 48 h, the A431 cultures showed significantly decreased proliferation. At 72 h after irradiation, {sup 131}I-Erbi resulted in more pronounced inhibition of cell proliferation than the cold antibody in all radiation dose groups. Conclusion: {sup 131}I-Erbi was stable for <=72 h. Radiotherapy led to increased tumor cell uptake of {sup 131}I-Erbi. Radiotherapy and {sup 131}I-Erbi synergistically inhibited tumor cell proliferation. These results provide the prerequisite data for a planned in vivo study of whole brain radiotherapy plus cetuximab for brain metastases.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Role for Adjuvant RFA in Managing Hepatic Metastases from Gastrointestinal Stromal Tumors (GIST) After Treatment with Targeted Systemic Therapy Using Kinase Inhibitors

Purpose: This study was designed to assess the role of radiofrequency ablation (RFA) in the multimodality management of gastrointestinal stromal tumors (GIST) in patients undergoing targeted tyrosine kinase inhibitor therapy (TKI) for liver metastases. Methods: Outcomes of 17 patients who underwent liver RFA for 27 metastatic GIST after TKI therapy, from January 2004 to March 2012, were retrospectively analyzed. Mean maximum tumor diameter was 2.5 ± 1 cm (range 0.9–4.5 cm). In seven patients (group A), RFA of all residual tumors was performed, with curative intent, and TKI therapy was discontinued. In five patients (group B), RFA of all residual tumors was performed upon achieving the best morphological response with TKI therapy, which was maintained after RFA. In another five patients (group C), RFA was performed on individual liver metastases which were progressive under TKI therapy. Results: All 27 targeted tumors were completely ablated, without local recurrence during the mean follow-up period of 49 months. No major complications occurred. Two minor complications were reported (11 %). Only two patients (both in group C) died at 20 and 48 months. Two-year progression-free survival (PFS) after RFA was 29 % in group A, 75 % in group B, and 20 % in group C. Conclusions: RFA in patients, previously treated with TKI, is feasible and safe. Our data suggest that RFA is a useful therapeutic option in patients with metastatic GIST and should be performed at the time of best clinical response with patient maintained under TKI after the procedure.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Probing the deep nonlinear stage of the ablative Rayleigh-Taylor instability in indirect drive experiments on the National Ignition Facility

Academic tests in physical regimes not encountered in Inertial Confinement Fusion will help to build a better understanding of hydrodynamic instabilities and constitute the scientifically grounded validation complementary to fully integrated experiments. Under the National Ignition Facility (NIF) Discovery Science program, recent indirect drive experiments have been carried out to study the ablative Rayleigh-Taylor Instability (RTI) in transition from weakly nonlinear to highly nonlinear regime [A. Casner et al., Phys. Plasmas 19, 082708 (2012)]. In these experiments, a modulated package is accelerated by a 175 eV radiative temperature plateau created by a room temperature gas-filled platform irradiated by 60 NIF laser beams. The unique capabilities of the NIF are harnessed to accelerate this planar sample over much larger distances (≃1.4 mm) and longer time periods (≃12 ns) than previously achieved. This extended acceleration could eventually allow entering into a turbulent-like regime not precluded by the theory for the RTI at the ablation front. Simultaneous measurements of the foil trajectory and the subsequent RTI growth are performed and compared with radiative hydrodynamics simulations. We present RTI growth measurements for two-dimensional single-mode and broadband multimode modulations. The dependence of RTI growth on initial conditions and ablative stabilization is emphasized, and we demonstrate for the first time in indirect-drive a bubble-competition, bubble-merger regime for the RTI at ablation front.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Operando Structure Determination of Cu and Zn on Supported MgO/SiO 2 Catalysts during Ethanol Conversion to 1,3-Butadiene

Electronic structure and reactivity of Cu- and Zn-promoted wet kneaded MgO/SiO 2 catalysts was interrogated during ethanol reaction to 1,3-BD. A multimodal nature of characterization, including in situ or operando X-ray, electron, light spectroscopies and steady state reactivity measurements demonstrated critical new information on the temporal evolution of the catalyst active sites including key measurements performed operando using synchrotron source (EXAFS and XANES). In situ DRIFT spectroscopy allowed to decouple the aldol condensation and dehydrogenation reactive steps due to the promotion with enhanced ability to carry out aldol condensation, as correlated with the steady state reactivity experiments . In situ UV-Vis spectroscopy presented a complex picture of the adsorbates with π- π* electronic transitions due to the allylic cations, cyclic or aromatic species while also suggesting oligomeric CuO species were formed. Operando X-ray measurements combined with ab initio multiple scattering modelling performed as a function of temperature identified a new transient intermediate assigned to a 4-fold coordinate Cu species that was key leading to increase in Cu-Cu pair number. For the first time, two types of Zn pairs, namely Zn-O and Zn-Mg, were identified during X-ray analysis under operating conditions. With Zn nearly 6-coordinated when in the vicinity of Mg while Zn-O species coordinated to nearly 4 nearest neighbors. The data suggest that such supported catalyst deactivation might proceed not only via carbon coking mechanism but also through the dispersed Cu site diffusion and growth due to the nearest neighbor oxygen atoms loss. The results presented suggest intermediates for segregation/deactivation mechanisms for a broader set of supported Cu and Zn catalysts used for alcohol upgrading catalytic reactions.

1,3-butadiene↗

Assessment of Flow-Enhanced Electrochemical Sensor Testing and Deployments for MSRs

This report serves as the deliverable for Milestone M3RS-23AN0401061 that is part of Work Package RS-23AN040106 (Flow Enhanced Sensors for MSRs – ANL). The goal of this milestone was to determine performance of the flow enhanced electrochemical sensor (FEES) and modular flow instrumentation testbed (MFIT) in safeguards relevant scenarios. Flow enhanced electrochemical sensors are a type of electroanalytical sensor that has been developed at Argonne National Laboratory to be installed directly into MSR flow conduits to make measurements of the salt composition. These sensors represent a significant improvement in capabilities compared to earlier electroanalytical sensors that instead can only be operated in quiescent conditions. Previous work has focused on testing of the FEES in flowing conditions provided by the MFIT to assess the accuracy and precision of the sensor measurements. To further improve this capability, in FY23 we undertook a campaign of safeguards relevant scenarios in molten salt containing a range of uranium chloride concentrations (0 to 3 wt%). All the testing carried out in FY23 was aided by a control system designed to automatically actuate flow conditions and collect data. This new automation system is estimated to have increased experimental throughput by a factor of four and enabled testing in a variety of complex conditions. The advancements in throughput and repeatability led to improved quantification of actinide concentrations using the in-flow sensors, with a reduction of the mean absolute relative error from 5.6% in FY22 to 3.1% in FY23. In addition to safeguards scenarios run in the MFIT, FY23 work included deployment of a FEES at a partner institution where it will be tested in a flowing salt loop. The FEES was successfully integrated into that loop and is being tested prior to loop startup. In FY23, work also continued on the smaller flow system that we have named the mini-MFIT. This smaller system is capable of rapid prototyping of new sensor designs prior to installation in the larger MFIT radiological flow system. Work was carried out to test this new system in non-radiological molten salts in a separate glovebox. This work is helping us to enhance the accuracy of our salt monitoring capabilities through the integration of multiple types of sensors. The high degree of accuracy required by 10 CFR 74 represents a significant challenge, and further design evolution and integration of the sensors into multimodal sensing frameworks will be needed to further push the measurement accuracy to the needed level.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Arbitrary-ratio power splitter based on nonlinear multimode interference coupler

We propose an ultra-compact multimode interference (MMI) power splitter based on nonlinear effects from simulations using nonlinear modal propagation analysis (NMPA) cooperation with finite difference Method (FDM) to access free choice of splitting ratio. Conventional multimode interference power splitter could only obtain a few discrete ratios. The power splitting ratio may be adjusted continuously while the input set power is varying by a tunable laser. In fact, using an ultra- compact MMI with a simple structure that is launched by a tunable nonlinear input fulfills the problem of arbitrary-ratio in integrated photonics circuits. Silicon on insulator (SOI) is used as the offered material due to the high contrast refractive index and Centro symmetric properties. The high-resolution images at the end of the multimode waveguide in the simulated power splitter have a high power balance, whereas access to a free choice of splitting ratio is not possible under the linear regime in the proposed length range except changes in the dimension for any ratio. The compact dimensions and ideal performance of the device are established according to optimized parameters. The proposed regime can be extended to the design of M×N arbitrary power splitters ratio for programmable logic devices in all optical digital signal processing. The results of this study indicate that nonlinear modal propagation analysis solves the miniaturization problem for all-optical devices based on MMI couplers to achieve multiple functions in a compact planar integrated circuit and also overcomes the limitations of previously proposed methods for nonlinear MMI.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Heterogeneous fatigue damage in a nickel-based single-crystal superalloy unraveled using correlative 3D X-ray technology

Nickel-based single-crystal (Ni-SX) superalloys under cyclic stress are susceptible to cracking at stress-concentration sites, eventually leading to low-cycle fatigue (LCF) failure. LCF cracks typically originate from intrinsic defects (e.g., voids and carbides) within solidified dendrites. However, systematic quantitative experimental analyses of defect-mediated local damage remain limited. To thoroughly understand the microscopic origins and evolution of LCF damage, correlated 3D mapping of dendrites across various regions is essential. Here, in this study, macroscale micro-computed tomography (μ-CT) was initially used to capture internal interdendritic secondary cracks within bulk DD413 superalloy after LCF testing at 760 °C. Subsequently, a multimodal methodology combining synchrotron 3D microdiffraction (3D-μXRD), high-resolution μ-CT, and electron microscopy was established. This approach allowed precise localization of internal damage zones near interdendritic secondary cracks and detailed mapping of the 3D correlated distributions of dendrites, defects, and residual stress/strain fields within these zones at submicron spatial resolution. Finally, the same approach was applied to specimens subjected to interrupted loading at approximately 40 % of the fatigue life to uncover the early damage states of dendrites. The dendrite cores (DCs) and interdendritic regions (IDs) exhibit microscale heterogeneous mechanical responses: nearly defect-free DCs accumulate local irreversible slip along specific slip systems to generate slip bands, while the IDs containing various defects accommodate local microplasticity through the activation of multiple slip systems around these defects. The local tensile stress near defects in the IDs exceeds that in the DC slip band regions by more than threefold, leading to the generation of local damage zones within the IDs. Chain-like defect distributions facilitate the interconnection of these local zones into a continuous damage region, further elevating the overall tensile stress in the IDs. Additionally, geometrically necessary dislocations alone are insufficient as indicators of LCF damage; both the internal stress state and its magnitude must be considered. These experimental results provide critical data and insights for the development of multi-physics fatigue models.

Localized deformation↗

NASA Tech Briefs, November 2009

Topics covered include: Cryogenic Chamber for Servo-Hydraulic Materials Testing; Apparatus Measures Thermal Conductance Through a Thin Sample from Cryogenic to Room Temperature; Rover Attitude and Pointing System Simulation Testbed; Desktop Application Program to Simulate Cargo-Air-Drop Tests; Multimodal Friction Ignition Tester; Small-Bolt Torque-Tension Tester; Integrated Spacesuit Audio System Enhances Speech Quality and Reduces Noise; Hardware Implementation of a Bilateral Subtraction Filter; Simple Optoelectronic Feedback in Microwave Oscillators; Small X-Band Oscillator Antennas; Free-Space Optical Interconnect Employing VCSEL Diodes; Discrete Fourier Transform Analysis in a Complex Vector Space; Miniature Scroll Pumps Fabricated by LIGA; Self-Assembling, Flexible, Pre-Ceramic Composite Preforms; Flight-speed Integral Image Analysis Toolkit; Work Coordination Engine; Multi-Mission Automated Task Invocation Subsystem; Autonomously Calibrating a Quadrupole Mass Spectrometer; Determining Spacecraft Reaction Wheel Friction Parameters; Composite Silica Aerogels Opacified with Titania; Multiplexed Colorimetric Solid-Phase Extraction; Detecting Airborne Mercury by Use of Polymer/Carbon Films; Lattice-Matched Semiconductor Layers on Single Crystalline Sapphire Substrate; Pressure-Energized Seal Rings to Better Withstand Flows; Rollerjaw Rock Crusher; Microwave Sterilization and Depyrogenation System; Quantifying Therapeutic and Diagnostic Efficacy in 2D Microvascular Images; NiF2/NaF:CaF2/Ca Solid-State High-Temperature Battery Cells; Critical Coupling Between Optical Fibers and WGM Resonators; Microwave Temperature Profiler Mounted in a Standard Airborne Research Canister; Alternative Determination of Density of the Titan Atmosphere; Solar Rejection Filter for Large Telescopes; Automated CFD for Generation of Airfoil Performance Tables; Progressive Classification Using Support Vector Machines; Active Learning with Irrelevant Examples; A Data Matrix Method for Improving the Quantification of Element Percentages of SEM/EDX Analysis; Deployable Shroud for the International X-Ray Observatory; Improved Model of a Mercury Ring Damper; Optoelectronic pH Meter: Further Details; X-38 Advanced Sublimator; and Solar Simulator Represents the Mars Surface Solar Environment.

Source record↗

Impact of Blast Overpressure on the Pharmacokinetics of Various Antibiotics in Sprague Dawley Rats

ABSTRACT Introduction Combat injuries are complex and multimodal. Most injuries to the extremities occur because of explosive devices such as improvised explosive devices. Blast exposure dramatically increases the risk of infection in combat wounds, and there is limited available information on the best antibiotic treatments for these injuries. We previously demonstrated that mice exposed to blast displayed a delayed clearance of cefazolin from the plasma and liver; further semi-mechanistic modeling determined that cefazolin concentrations in the skin of these mice were reduced. Our objective was to investigate the effects of blast on the pharmacokinetics of antibiotics of different types used for the treatment of combat wounds in the rat model. Materials and Methods Male Sprague Dawley rats were exposed to blast overpressure followed by injection of a bolus of animal equivalent doses of an antibiotic (cefazolin, cefepime, ertapenem, or clindamycin) into the tail vein at 1-hour post-blast exposure. Blood was collected at predetermined time points via repeated sampling from the tail vein. Animals were also euthanized at predetermined time points, at which time liver, kidney, skin, and blood via cardiac puncture were collected. Antibiotic concentrations were determined by ultra-performance liquid chromatography–tandem mass spectrometry. Results Blast-exposed rats exhibited a similar rate of clearance compared to non-blasted rats in the blood, liver, kidney, and skin, which is inconsistent with the data regarding cefazolin in blast-exposed mice. Conclusions Our results in rats do not recapitulate our previous observation of delayed cefazolin clearance in mice following the blast overpressure exposure. Although using rats permitted us to collect multiple blood samples from the same animals, rats may not be a suitable model for measuring the pharmacokinetics of antibiotics following blast. The interpretation of the results may be challenging because of variation in data among rat subjects in the same sample groups.

General & Internal Medicine↗

Addressing Critical Problems in Materials Science Through Multiscale and Multimode Characterization (Project 1); Characterization and Optimization of Novel Triple-Conducting Oxide Materials for Energy Applications (Project 2) (CRADA Final Report)

PROJECT 1: Address critical problems in materials science and simultaneously advance the state-of-the-art in multiscale and multimode characterization using the combined advanced analytical capabilities and expertise of Colorado School of Mines (CSM) and the National Renewable Energy Laboratory (NREL). The primary effort of the Phase I of this CRADA is to establish the International Center for Multiscale Characterization using shared resources at both NREL and CSM. Phase II will focus on capability development and marketing, choosing candidate materials science issues in the areas of structure imaging, chemical composition mapping, and correlating properties and performance of materials for impact in energy-related, environmental and critical materials areas. The CRADA will be modified to include specific topics of concern in materials science to industry member partners. Advanced analytical capabilities and expertise at CSM and NREL will be used to advance materials understanding and performance through characterization of multiscale phenomena including structural imaging, chemical composition mapping, and other techniques correlating properties and performance of materials. PROJECT 2: As part of the International Center for Materials Characterization, work under Modification #1 will be led by Colorado School of Mines (CSM), working in collaboration with NREL staff to mentor and advise CSM postdoctoral researchers on set up of diffusion annealing experiments. The purpose of the modification is to provide for NREL staff to mentor and advise CSM postdoctoral researchers on set up of diffusion annealing experiments, including mentoring and advising the CSM-NREL team on proper Secondary Ion Mass Spectrometry (SIMS) data analysis as needed. SIMS measurements of 10-20 samples will be performed at NREL during the project duration.

08 HYDROGEN↗

Multimodality Local Therapy for Retroperitoneal Sarcoma

Purpose: Soft-tissue sarcomas of the retroperitoneum are rare tumors comprising less than 1% of all malignancies. Although surgery continues as the mainstay of treatment, the large size of these tumors coupled with their proximity to critical structures make resection with wide margins difficult to achieve. The role and timing of radiotherapy are controversial. This study updates our institutional experience using multimodality local therapy for resectable retroperitoneal sarcoma and identifies prognostic factors impacting disease control and survival. Methods and Materials: Between 1974 and 2007, 58 patients with nonmetastatic retroperitoneal sarcoma were treated with surgery and radiation at University of Florida. The median age at radiotherapy was 57 years old (range, 18-80 years). Forty-two patients received preoperative radiotherapy and 16 received postoperative radiotherapy. Nineteen patients received 1.8 Gy once daily and 39 patients received 1.2 Gy twice daily. Variables analyzed for prognostic value included age, grade, kidney involvement, histology, de novo versus recurrent presentation, tumor diameter, margin status, radiotherapy sequencing (preoperative vs. postoperative), total radiation dose, fractionation scheme, and treatment era. Results: The 5-year overall survival, cause-specific survival, and local control rates were 49%, 58%, and 62%, respectively. Nearly two-thirds of disease failures involved a component of local progression. On multivariate analysis, only margin status was significantly associated with improved 5-year local control (85%, negative margins; 63%, microscopic positive margins; 0%, gross positive margins; p < 0.0001) and 5-year overall survival (64%, negative margins; 56%, microscopic positive margins; 13%, gross positive margins; p = 0.0012). Thirty-one Grade 3 or greater toxicities were observed in 22 patients, including two treatment-related deaths (3%). Conclusion: For retroperitoneal sarcoma, local control remains a challenge and combined-modality therapy may be associated with significant acute and late morbidity. Our patterns of failure data suggest that improvements in local control may translate into a survival benefit.

62 RADIOLOGY AND NUCLEAR MEDICINE↗