Search NASA⌕ Search

SEARCH · Search NASA

Results for “multiple beams”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Radiography Capabilities for Matter-Radiation Interactions in Extremes

The Matter-Radiation Interactions in Extremes (MaRIE) experimental facility will be used to discover and design the advanced materials needed to meet 21st century national security and energy security challenges. This new facility will provide the new tools scientists need to develop next-generation materials that will perform predictably and on-demand for currently unattainable lifetimes in extreme environments. The MaRIE facility is based on upgrades to the existing LANSCE 800-MeV proton linac and a new 12-GeV electron linac and associated X-ray FEL to provide simultaneous multiple probe beams, and new experimental areas. In addition to the high-energy photon probe beam, both electron and proton radiography capabilities will be available at the MaRIE facility. Recently, detailed radiography system studies have been performed to develop conceptual layouts of high-magnification electron and proton radiography systems that can meet the experimental requirements for the expected first experiments to be performed at the facility. A description of the radiography systems, their performance requirements, and a proposed facility layout are presented.

43 PARTICLE ACCELERATORS↗

Solar light systems, and related components and methods

A solar light system may include two stages of optical concentration with intermediate removal of infrared radiation between the optical concentration stages. A second stage of optical concentration may prepare multiple concentrating beams of processed solar radiation with visible light with each such concentrating beam directed to a different corresponding light conduit for transmission to an interior space for interior lighting. System modularization may provide flexibility to accommodate a variety of interior lighting applications.

14 SOLAR ENERGY↗

Evaluation of Electron Energy Spread in CsBr Based Photocathodes

Photocathodes with relatively low energy spread (<0.5 eV) are required for electron sources in several applications including single and multiple electron beam inspection and lithography tools and free electron lasers. CsBr based photocathodes have been shown to be very robust and capable of operation at high current density (>150 A/cm{sup 2}) with very long lifetime (approximately hundreds of hours/spot). Experimental results of the photoelectron energy spread obtained in CsBr films deposited on both metal and InGaN substrates will be presented in this paper.

36 MATERIALS SCIENCE↗

A tetrahedron beam computed tomography benchtop system with a multiple pixel field emission x-ray tube

Purpose: To demonstrate the feasibility of Tetrahedron Beam Computed Tomography (TBCT) using a carbon nanotube (CNT) multiple pixel field emission x-ray (MPFEX) tube. Methods: A multiple pixel x-ray source facilitates the creation of novel x-ray imaging modalities. In a previous publication, the authors proposed a Tetrahedron Beam Computed Tomography (TBCT) imaging system which comprises a linear source array and a linear detector array that are orthogonal to each other. TBCT is expected to reduce scatter compared with Cone Beam Computed Tomography (CBCT) and to have better detector performance. Therefore, it may produce improved image quality for image guided radiotherapy. In this study, a TBCT benchtop system has been developed with an MPFEX tube. The tube has 75 CNT cold cathodes, which generate 75 x-ray focal spots on an elongated anode, and has 4 mm pixel spacing. An in-house-developed, 5-row CT detector array using silicon photodiodes and CdWO{sub 4} scintillators was employed in the system. Hardware and software were developed for tube control and detector data acquisition. The raw data were preprocessed for beam hardening and detector response linearity and were reconstructed with an FDK-based image reconstruction algorithm. Results: The focal spots were measured at about 1 x 2 mm{sup 2} using a star phantom. Each cathode generates around 3 mA cathode current with 2190 V gate voltage. The benchtop system is able to perform TBCT scans with a prolonged scanning time. Images of a commercial CT phantom were successfully acquired. Conclusions: A prototype system was developed, and preliminary phantom images were successfully acquired. MPFEX is a promising x-ray source for TBCT. Further improvement of tube output is needed in order for it to be used in clinical TBCT systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Total skin electron therapy (TSET): A reimplementation using radiochromic films and IAEA TRS-398 code of practice

Purpose: The aim of this work is to present an updated implementation of total skin electron therapy (TSET) using IAEA TRS-398 code of practice for absolute dosimetry and taking advantage of the use of radiochromic films. The optimization of quality control tests is also included. Methods: A Varian 2100 C/D linear accelerator equipped with the special procedure HDTSe{sup -} (high dose rate total skin electron mode, E=6 MeV) was employed to perform TSET irradiations using the modified Stanford technique. The commissioning was performed following the AAPM report 23 recommendations. In particular, for dual-field beams irradiation, the optimal tilt angle was investigated and the dose distribution in the treatment plane was measured. For a complete six dual-field beams irradiation, the treatment skin dose on the surface of a cylindrical phantom was evaluated by radiochromic films and the B factor which relates the single dual-field skin dose to the six dual-field skin dose was assessed. Since the TRS-398 reference conditions do not meet the requirements of TSET absolute dosimetry, GafChromic EBT films were also employed to check and validate the application of the protocol. Simplified procedures were studied to verify beam constancy in PMMA phantoms without the more difficult setup of total skin irradiation. Results: The optimized geometrical setup for dual-field beams was: Tilt angle={+-}19 deg., SSD=353 cm, and the beam degrader (200x100x1 cm{sup 3}) placed at 320 cm from the source. As regards to dose homogeneity in the treatment plane, for dual-field beams irradiation, the mean relative dose value was 97%{+-}5% (normalizing to 100% at the calibration point level). For six dual-field beams irradiation, the multiplication factor B was 2.63. In addition, beam quality, dose rate, and bremsstrahlung contribution were also suitable for TSET treatments. The TRS-398 code of practice was used for TSET dosimetry, as dose measurements performed by ionization chamber and radiochromic film agreed within 2.5%. Simplified quality control tests and baseline values were presented in order to check flatness, symmetry, and field size with radiochromic films and output and beam quality constancy with ionization chamber. Short-term reproducibility and MU linearity tests were also included. Conclusions: Commissioning parameters met the requirements of TSET treatments and the matching of AAPM guidelines with the IAEA code of practice was successful. Frequent beam performance controls can be easily performed through the presented quality assurance tests. Radiochromic dosimetry facilitated the TSET commissioning and played a major role to validate the application of TRS-398.

60 APPLIED LIFE SCIENCES↗

Characterization of GaAlAs optical waveguide heterostructures grown by molecular beam epitaxy

Multiple-layer GaAlAs optical waveguide heterostructures have been grown by MBE. These samples were designed to operate at 840 nm with negligible coupling of guided light to the absorbing GaAs substrate. The Al concentration was 13 percent for the guiding layer and was 16 percent for the cladding layers. The process for growing waveguide layers was calibrated primarily by high-energy electron diffraction, with the optical quality confirmed by photoluminescence measurements. Channel waveguide structures having widths of 5 microns were etched in a low-pressure magnetically confined multipolar plasma reactor. The resulting waveguide structures were characterized by Raman spectroscopy, ellipsometry, AES, and optical-waveguide loss measurements.

Radens, C. J.↗

Multiple-mode nonlinear free and forced vibrations of beams using finite element method

Effects of large deflection geometric nonlinearity and multiple modes for free and forced vibrations of beams are investigated. Inplane displacement and inplane inertia are included in the formulation. The finite element method is employed. A harmonic force matrix is derived for forced vibration analysis. The relations of amplitude, frequency ratio and forcing intensity for beams of different boundary conditions and various load conditions are presented.

Mei, Chuh↗

Design of a multi beam klystron cavity from its single beam parameters

The klystron is a well-known microwave amplifier which uses kinetic energy of an electron beam for amplification of the RF signal. There are some limitations of conventional single beam klystron such as high operating voltage, low efficiency and bulky size at higher power levels, which are very effectively handled in Multi Beam Klystron (MBK) that uses multiple low purveyance electron beams for RF interaction. Each beam propagates along its individual transit path through a resonant cavity structure. Multi-Beam klystron cavity design is a critical task due to asymmetric cavity structure and can be simulated by 3D code only. The present paper shall discuss the design of multi beam RF cavities for klystrons operating at 2856 MHz (S-band) and 5 GHz (C-band) respectively. The design approach uses some scaling laws for finding the electron beam parameters of the multi beam device from their single beam counter parts. The scaled beam parameters are then used for finding the design parameters of the multi beam cavities. Design of the desired multi beam cavity can be optimized through iterative simulations in CST Microwave Studio.

42 ENGINEERING↗

Study of the crystal device for deflecting high-energy proton beams using synchrotron radiation diffraction

Currently, bent silicon single crystals are used at large accelerators to extract and collimate proton beams. A device for multiple deflection of a proton beam based on several bent silicon strips operating in the volume reflection mode has recently been developed. In this device, the bending of silicon strips successively located on the surface of a thick plate is implemented due to the internal stress induced by grooves mechanically formed on the crystal surface (Twyman effect). Topography based on angular scanning and synchrotron radiation was applied to measure the bending of individual deflector strips and the crystal as a whole. The measurement results are compared with the data obtained with a proton beam.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

High Brightness High Duty Factor Negative Ion Beam Injector [Slides]

The high brightness negative ion injector combines multiple individual low-duty-factor H- ion sources (multiplexing) in a manner that allows flexibility in final pulse format and beam duty factor up to CW and increases reliability by eliminating an otherwise single-point failure usually associated with using a single ion source. The multiplexing of multiple beams in new injector system also preserves the beam quality of each individual ion source, eliminating a significant source of beam quality degradation usually associated with combining beams.

43 PARTICLE ACCELERATORS↗

Attosecond x-ray free-electron lasers utilizing an optical undulator in a self-selection regime

Accelerator-based x-ray free-electron lasers (XFELs) are the latest addition to the revolutionary tools of discovery for the 21st century. The two major components of an XFEL are an accelerator-produced electron beam and a magnetic undulator, which tend to be kilometer-scale long and expensive. A proof-of-principle demonstration of free-electron lasing at 27 nm using beams from compact laser wakefield accelerators was shown recently by using a magnetic undulator. However, scaling these concepts to x-ray wavelengths is far from straightforward as the requirements on the beam quality and jitters become much more stringent. Here, we present an ultracompact scheme to produce tens of attosecond x-ray pulses with several GW peak power utilizing a novel aspect of the FEL instability using a highly chirped, prebunched, and ultrabright tens of MeV electron beam from a plasma-based accelerator interacting with an optical undulator. The FEL resonant relation between the prebunched period and the energy selects resonant electrons automatically from the highly chirped beam which leads to a stable generation of attosecond x-ray pulses. Furthermore, two-color attosecond pulses with subfemtosecond separation can be produced by adjusting the energy distribution of the electron beam so that multiple FEL resonances occur at different locations within the beam. Such a tunable coherent attosecond x-ray sources may open up a new area of attosecond science enabled by x-ray attosecond pump/probe techniques. Published by the American Physical Society 2024

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Experimental characterization of quantum correlated triple beams generated by cascaded four-wave mixing processes

Quantum correlations and entanglement shared among multiple modes are fundamental ingredients of most continuous-variable quantum technologies. Recently, a method used to generate multiple quantum correlated beams using cascaded four-wave mixing (FWM) processes was theoretically proposed and experimentally realized by our group [Z. Qin et al., Phys. Rev. Lett. 113, 023602 (2014)]. Our study of triple-beam quantum correlation paves the way to showing the tripartite entanglement in our system. Our system also promises to find applications in quantum information and precision measurement such as the controlled quantum communications, the generation of multiple quantum correlated images, and the realization of a multiport nonlinear interferometer. For its applications, the degree of quantum correlation is a crucial figure of merit. In this letter, we experimentally study how various parameters, such as the cell temperatures, one-photon, and two-photon detunings, influence the degree of quantum correlation between the triple beams generated from the cascaded two-FWM configuration.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Alternative Beam Efficiency Calculations for a Large-aperture Multiple-frequency Microwave Radiometer (LAMMR)

The fundamental definition of beam efficiency, given in terms of a far field radiation pattern, was used to develop alternative definitions which improve accuracy, reduce the amount of calculation required, and isolate the separate factors composing beam efficiency. Well-known definitions of aperture efficiency were introduced successively to simplify the denominator of the fundamental definition. The superposition of complex vector spillover and backscattered fields was examined, and beam efficiency analysis in terms of power patterns was carried out. An extension from single to dual reflector geometries was included. It is noted that the alternative definitions are advantageous in the mathematical simulation of a radiometer system, and are not intended for the measurements discipline where fields have merged and therefore lost their identity.

Schmidt, R. F.↗

Analysis of the NorthStar Inconel 718 Window

NorthStar Medical Radioisotopes, LLC, is planning to produce the important medical radioisotope molybdenum-99 (Mo-99) through photonuclear reactions in molybdenum-100 (Mo-100). In this approach, a target comprising multiple thin disks of enriched molybdenum metal will be bombarded with a 40-MeV electron beam. Because enriched Mo-100 is expensive, there is a desire to utilize as much beam power as possible to achieve maximum production yield and minimize the size of the target. This requirement leads to very high beam power density (heat deposition in the target), which sets challenging requirements for cooling of the target. In the latest concept developed by NorthStar, a stack of target (sintered molybdenum) disks is irradiated from two sides by a 40-MeV electron beam, with a total power of 240 kW (120 kW from each side). As shown in Figure 1, the target disks are cooled by pressurized helium gas flowing through channels between the disks. A housing encloses the target disks and helium coolant. Thinned regions on opposite sides of the housing act as windows, forming the pressure boundary between the helium within the housing and the evacuated beam tube. A pulsed (50-Hz) 40-MeV electron beam is used, with 120 kW total power and a 10% duty cycle. The pulsing beam creates a corresponding cyclic thermal load within the window material. To examine the effects of the cyclic thermal load on the window, a combination of analyses was performed, including computational fluid dynamics (CFD) and finite element analysis (FEA). The analyses presented in this report were primarily performed using the finite element method. However, because of the curved surface of the window, CFD analysis was used to calculate the convective cooling boundary included in the FEA model. Transient thermal and structural models were used to explore the window geometry, including thickness, radius of curvature, and diameter, while staying within the temperature and stress limits of the material as well as maintaining mechanical stability (i.e., avoiding buckling). Additionally, variations in the size and location of the electron beam were evaluated. Multiple parameters for the window and the electron beam were examined throughout the analysis. Upper and lower bounds were established for the window geometry parameters, and limitations were established for the size and position of the electron beam.

62 RADIOLOGY AND NUCLEAR MEDICINE↗