Search NASA⌕ Search

SEARCH · Search NASA

Results for “optical Interferometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

MegaMIR: The Megapixel Mid-Infrared Instrument for the Large Binocular Telescope Interferometer

The Megapixel Mid-infrared Instrument (MegaMIR) is a proposed Fizeau-mode camera for the Large Binocular Telescope operating at wavelengths between 5 and 28 micrometers. The camera will be used in conjunction with the Large Binocular Telescope Interferometer (LBTI), a cryogenic optical system that combines the beams from twin 8.4-m telescopes in a phase coherent manner. Unlike other interferometric systems, the co-mounted telescopes on the LBT satisfy the sine condition, providing diffraction-limited resolution over the 40" field of view of the camera. With a 22.8-m baseline, MegaMIR will yield 0.1" angular resolution, making it the highest resolution wide field imager in the thermal infrared for at least the next decade. MegaMIR will utilize a newly developed 1024 x 1024 pixel Si:As detector array that has been optimized for use at high backgrounds. This new detector is a derivative of the Wide-field Infrared Survey Explorer (WISE) low-background detector. The combination of high angular resolution and wide field imaging will be a unique scientific capability for astronomy. Key benefits will be realized in planetary science, galactic, and extra-galactic astronomy. High angular resolution is essential to disentangle highly complex sources, particularly in star formation regions and external galaxies, and MegaMIR provides this performance over a full field of view. Because of the great impact being made by space observatories like the Spitzer Space Telescope, the number of available targets for study has greatly increased in recent years, and MegaMIR will allow efficient follow up science.

ultraluminous galaxies↗

A Massive Bipolar Outflow and a Dusty Torus with Large Grains in the Preplanetary Nebula IRAS 22036+5306

We report high angular resolution (approx.1") CO J=3-2 interferometric mapping using the Submillimeter Array (SMA) of IRAS 22036+5306 (I22036), a bipolar preplanetary nebula (PPN) with knotty jets discovered in our HST snapshot survey of young PPNs. In addition, we have obtained supporting lower resolution (approx.10") CO and 13CO J=1-0 observations with the Owens Valley Radio Observatory (OVRO) interferometer, as well as optical long-slit echelle spectra at the Palomar Observatory. The CO J=3-2 observations show the presence of a very fast (approx.220 km/s), highly collimated, massive (0.03 Solar Mass) bipolar outflow with a very large scalar momentum (about 10(exp 39) g cm/s), and the characteristic spatiokinematic structure of bow shocks at the tips of this outflow. The H(alpha) line shows an absorption feature blueshifted from the systemic velocity by approx.100 km/s, which most likely arises in neutral interface material between the fast outflow and the dense walls of the bipolar lobes at low latitudes. The fast outflow in I22036, as in most PPNs, cannot be driven by radiation pressure. We find an unresolved source of submillimeter (and millimeter-wave) continuum emission in I22036, implying a very substantial mass (0.02-0.04 Solar Mass) of large (radius > or approx.1 mm), cold (< or approx.50 K) dust grains associated with I22036's toroidal waist. We also find that the C-13/C-12 ratio in I22036 is very high (0.16), close to the maximum value achieved in equilibrium CNO nucleosynthesis (0.33). The combination of the high circumstellar mass (i.e., in the extended dust shell and the torus) and the high C-13/C-12 ratio in I22036 provides strong support for this object having evolved from a massive (> or approx.4 Solar Mass) progenitor in which hot-bottom-burning has occurred.

stars↗

Polarization Effects Aboard the Space Interferometry Mission

For precision displacement measurements, laser metrology is currently one of the most accurate measurements. Often, the measurement is located some distance away from the laser source, and as a result, stringent requirements are placed on the laser delivery system with respect to the state of polarization. Such is the case with the fiber distribution assembly (FDA) that is slated to fly aboard the Space Interferometry Mission (SIM) next decade. This system utilizes a concatenated array of couplers, polarizers and lengthy runs of polarization-maintaining (PM) fiber to distribute linearly-polarized light from a single laser to fourteen different optical metrology measurement points throughout the spacecraft. Optical power fluctuations at the point of measurement can be traced back to the polarization extinction ration (PER) of the concatenated components, in conjunction with the rate of change in phase difference of the light along the slow and fast axes of the PM fiber.

fiber distribution↗

Multi-Point Interferometric Rayleigh Scattering using Dual-Pass Light Recirculation

This paper describes for the first time an interferometric Rayleigh scattering system using dual-pass light recirculation (IRS-LR) capable of simultaneously measuring at multiple points two orthogonal components of flow velocity in combustion flows using single shot laser probing. An additional optical path containing the interferometer input mirror, a quarter-wave plate, a polarization dependent beam combiner, and a high reflectivity mirror partially recirculates the light that is rejected by the interferometer. Temporally- and spatially-resolved acquisitions of Rayleigh spectra in a large-scale combustion-heated supersonic axi-symmetric jet were performed to demonstrate the technique. Recirculating of Rayleigh scattered light increases the number of photons analyzed by the system up to a factor of 1.8 compared with previous configurations. This is equivalent to performing measurements with less laser energy or performing measurements with the previous system in gas flows at higher temperatures.

Bivolaru, Daniel↗

The Primordial Inflation Explorer (PIXIE) Mission

The Primordial Inflation Explorer (PIXIE) is an Explorer-class mission to map the absolute intensity and linear polarization of the cosmic microwave background and diffuse astrophysical foregrounds over the full sky from frequencies 30 GHz to 6 THz (I cm to 50 I-tm wavelength). PIXIE uses a polarizing Michelson interferometer with 2.7 K optics to measure the difference spectrum between two orthogonal linear polarizations from two co-aligned beams. Either input can view either the sky or a temperature-controlled absolute reference blackbody calibrator. The multimoded optics and high etendu provide sensitivity comparable to kilo-pixel focal plane arrays, but with greatly expanded frequency coverage while using only 4 detectors total. PIXIE builds on the highly successful COBEIFIRAS design by adding large-area polarization-sensitive detectors whose fully symmetric optics are maintained in thermal equilibrium with the CMB. The highly symmetric nulled design provides redundant rejection of major sources of systematic uncertainty. The principal science goal is the detection and characterization of linear polarization from an inflationary epoch in the early universe, with tensor-to-scalar ratio r much less than 10(exp -3). PIXIE will also return a rich data set constraining physical processes ranging from Big Bang cosmology, reionization, and large-scale structure to the local interstellar medium. Keywords: cosmic microwave background, polarization, FTS, bolometer

Kogut, Alan J.↗

Nonlinear interferometer systems and methods

Nonlinear interferometers include a nonlinear optical medium that is situated to produce a conjugate optical beam in response to a pump beam and a probe beam. The pump, probe, and conjugate beams propagate displaced from each other along a common optical path. One of the beams is selectively phase shifted, and the beams are then returned to the nonlinear medium, with the selectively phase shift beam phase shifted again. The nonlinear medium provides phase sensitive gain to at least one of the probe or conjugate beams, and the amplified beam is detected to provide an estimate of the phase shift.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Fourier Transform Fabry-Perot Interferometer

We are developing a compact, rugged, high-resolution remote sensing instrument with wide spectral scanning capabilities. This relatively new type of instrument, which we have chosen to call the Fourier-Transform Fabry-Perot Interferometer (FT-FPI), is accomplished by mechanically scanning the etalon plates of a Fabry-Perot interferometer (FPI) through a large optical distance while examining the concomitant signal with a Fourier-transform analysis technique similar to that employed by the Michelson interferometer. The FT-FPI will be used initially as a ground-based instrument to study near-infrared atmospheric absorption lines of trace gases using the techniques of solar absorption spectroscopy. Future plans include modifications to allow for measurements of trace gases in the stratosphere using spectral lines at terahertz frequencies.

Snell, Hilary E.↗

Visibility bound caused by a distinguishable noise particle

We investigate how the distinguishability of a 'noise' particle degrades interference of the 'signal' particle. The signal, represented by an equatorial state of a photonic qubit, is mixed with noise, represented by another photonic qubit, via linear coupling on a beam splitter. We report on the degradation of the signal photon interference depending on the degree of indistinguishability between the signal and noise photons. When the photons are completely distinguishable in principle but technically indistinguishable, the visibility drops to the value 1/{radical}(2). As the photons become more indistinguishable, the maximal visibility increases and reaches the unit value for completely indistinguishable photons. We have examined this effect experimentally using a setup with a fiber-optics two-photon Mach-Zehnder interferometer.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Silicon Carbide Mounts for Fabry-Perot Interferometers

Etalon mounts for tunable Fabry- Perot interferometers can now be fabricated from reaction-bonded silicon carbide structural components. These mounts are rigid, lightweight, and thermally stable. The fabrication of these mounts involves the exploitation of post-casting capabilities that (1) enable creation of monolithic structures having reduced (in comparison with prior such structures) degrees of material inhomogeneity and (2) reduce the need for fastening hardware and accommodations. Such silicon carbide mounts could be used to make lightweight Fabry-Perot interferometers or could be modified for use as general lightweight optical mounts. Heretofore, tunable Fabry-Perot interferometer structures, including mounting hardware, have been made from the low-thermal-expansion material Invar (a nickel/iron alloy) in order to obtain the thermal stability required for spectroscopic applications for which such interferometers are typically designed. However, the high mass density of Invar structures is disadvantageous in applications in which there are requirements to minimize mass. Silicon carbide etalon mounts have been incorporated into a tunable Fabry-Perot interferometer of a prior design that originally called for Invar structural components. The strength, thermal stability, and survivability of the interferometer as thus modified are similar to those of the interferometer as originally designed, but the mass of the modified interferometer is significantly less than the mass of the original version.

Lindemann, Scott↗

Lateral shearing interferometry for high-NA EUV wavefront metrology

Copyright © 2018 SPIE. We present a lateral shearing interferometer suitable for high-NA EUV wavefront metrology. In this interferometer, a geometric model is used to accurately characterize and predict systematic errors that come from performing interferometry at high NA. This interferometer is compatible with various optical geometries, including systems where the image plane is tilted with respect to the optical axis, as in the Berkeley MET5. Simulation results show that the systematic errors in tilted geometries can be reduced by aligning the shearing interferometer grating and detector parallel to the image plane. Subsequent residual errors can be removed by linear fitting.

Zhu, Wenhua↗

Measurement of ultrasonic fields in transparent media using a scanning differential interferometer

An experimental system for the detection of three dimensional acoustic fields in optically transparent media using a dual beam differential interferometer is described. In this system, two coherent, parallel, focused laser beams are passed through the specimen and the interference fringe pattern which results when these beams are combined shifts linearly by an amount which is related to the optical pathlength difference between the two beams. It is shown that for small signals, the detector output is directly proportional to the amplitude of the acoustic field integrated along the optical beam path through the specimen. A water tank and motorized optical platform were constructed to allow these dual beams to be scanned through an ultrasonic field generated by a piezoelectric transducer at various distances from the transducer. Scan data for the near, Fresnel, and far zones of a uniform, circular transducer are presented and an algorithm for constructing the radial field profile from this integrated optical data, assuming cylindrical symmetry, is described.

Dockery, G. D.↗

Digital holographic interferometry: A novel optical calorimetry technique for radiation dosimetry

Purpose: To develop and demonstrate the proof-of-principle of a novel optical calorimetry method to determine radiation absorbed dose in a transparent medium. Methods: The calorimetric property of water is measured during irradiation by means of an interferometer, which detects temperature-induced changes in the refractive index that can be mathematically related to absorbed dose. The proposed method uses a technique called digital holographic interferometry (DHI), which comprises an optical laser interferometer setup and consecutive physical reconstruction of the recorded wave fronts by means of the Fresnel transform. This paper describes the conceptual framework and provides the mathematical basis for DHI dosimetry. Dose distributions from a high dose rate Brachytherapy source were measured by a prototype optical setup to demonstrate the feasibility of the approach. Results: The developed DHI dosimeter successfully determined absorbed dose distributions in water in the region adjacent to a high dose rate Brachytherapy source. A temperature change of 0.0381 K across a distance of 6.8 mm near the source was measured, corresponding to a dose of 159.3 Gy. The standard deviation in a typical measurement set was ±3.45 Gy (corresponding to an uncertainty in the temperature value of ±8.3 × 10{sup −4} K). The relative dose fall off was in agreement with treatment planning system modeled data. Conclusions: First results with a prototype optical setup and a Brachytherapy source demonstrate the proof-of-principle of the approach. The prototype achieves high spatial resolution of approximately 3 × 10{sup −5} m. The general approach is fundamentally independent of the radiation type and energy. The sensitivity range determined indicates that the method is predominantly suitable for high dose rate applications. Further work is required to determine absolute dose in all three dimensions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Fiber-optic projected-fringe digital interferometry

A phase-stepped projected-fringe interferometer was developed which uses a closed-loop fiber-optic phase-control system to make very accurate surface profile measurements. The closed-loop phase-control system greatly reduces phase-stepping error, which is frequently the dominant source of error in digital interferometers. Two beams emitted from a fiber-optic coupler are combined to form an interference fringe pattern on a diffusely reflecting object. Reflections off of the fibers' output faces are used to create a phase-indicating signal for the closed-loop optical phase controller. The controller steps the phase difference between the two beams by pi/2 radians in order to determine the object's surface profile using a solid-state camera and a computer. The system combines the ease of alignment and automated data reduction of phase-stepping projected-fringe interferometry with the greatly improved phase-stepping accuracy of our closed-loop phase-controller. The system is demonstrated by measuring the profile of a plate containing several convex surfaces whose heights range from 15 to 25 micron high.

Mercer, Carolyn R.↗

Optical pathlength control in the nanometer regime on the JPL phase B interferometer testbed

This paper describes experimental research being performed at the Jet Propulsion Laboratory to develop and validate control concepts arising out of NASA's Control Structure Interaction program. The facility is meant to be a ground testbed with relevance to a broad class of future precision optical space systems. The objective of the experimental program is to investigate a multi-layer control approach to the maintenance of nanometer level optical pathlength control in the presence of external disturbances and multiple structural resonances. A brief overview of the experimental facility is presented. The control design methodology is discussed, and several experimental results are presented.

O'Neal, Michael C.↗

Implementation of Nonlinear Control Laws for an Optical Delay Line

This paper discusses the implementation of a globally stable nonlinear controller algorithm for the Real-Time Interferometer Control System Testbed (RICST) brassboard optical delay line (ODL) developed for the Interferometry Technology Program at the Jet Propulsion Laboratory. The control methodology essentially employs loop shaping to implement linear control laws. while utilizing nonlinear elements as means of ameliorating the effects of actuator saturation in its coarse, main, and vernier stages. The linear controllers were implemented as high-order digital filters and were designed using Bode integral techniques to determine the loop shape. The nonlinear techniques encompass the areas of exact linearization, anti-windup control, nonlinear rate limiting and modal control. Details of the design procedure are given as well as data from the actual mechanism.

Hench, John J.↗

LISA Optics and Orbital Motions

The Laser Interferometer Space Antenna (LISA) telescopes must be able to send to and receive light from the other two distant spacecraft. The angle between the distant spacecraft will vary by about one degree in the course of a year. In addition the send and receive directions, for any one telescope, will also vary because of changes in distance, relative velocities of the spacecraft and the flight time of the light. All of these (angular) motions place requirements on the telescope pointing mechanism and the compensating proof mass motions. In this paper we will present the magnitudes of these angular motions, within the context of Keplerian orbits, and the resulting image motions on the detectors.

Waluschka, Eugene↗

Non-destructive testing using two-component/two-wave mixing interferometer

A new laser-based ultrasonic (LBU) receiver was recently introduced. The novel architecture is based on two-wave mixing in photorefractive materials and allows simultaneous measurement of in-plane and out-of-plane displacements (two- component). By taking advantage of recent developments in electronic processing and our knowledge on multi-channel interferometer, we achieved a compact optical system using only a single collecting aperture and a single laser probe beam. We will characterize the system performances and present experimental results demonstrating the capability for this compact two-component interferometer.

42 ENGINEERING↗