Search NASA⌕ Search

SEARCH · Search NASA

Results for “optimized infrastructure”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

The water use of data center workloads: A review and assessment of key determinants

The global importance of data center water use is increasing with the rapid growth of digitalization and artificial intelligence. This study analyzes the factors influencing workload-level water use, measured in liters consumed per workload, to guide water-saving strategies in data centers. Our findings reveal workload-level water use variations exceeding 10,000-fold, driven by over 1000-fold differences in water consumption per kilowatt hour of server electricity consumed and approximately 10-fold differences in server workload efficiency. Key determinants are ranked as server efficiency, electrical grid water consumption factors, server utilization, cooling system type, infrastructure efficiency, climate zone, inactive server percentage, and server refresh cycle. Notably, there is no single recipe for minimizing water use; instead, optimal outcomes depend on tailored combinations of these factors. This analysis addresses critical knowledge gaps by identifying the determinants of data center water use and exploring their achievable minima under diverse site-specific constraints.

Data centers↗

Design and Analysis of a 200 kW Dynamic Wireless Charging System for Electric Vehicles

Dynamic wireless charging of electric vehicles can significantly alleviate or eliminate range anxiety while reducing the required on-board battery capacity. To achieve an electric vehicle charging balance with minimal infrastructure costs, power transfer levels around 200 kW are required. In this paper, a system architecture with a modularized power electronics and optimized power transfer couplers was adopted to enable efficient power transfer. A DC/DC converter was used for secondary-side charging control of the battery. The system performance was validated in an experimental setup at 120 kW with 91.31% efficiency from the DC input on the primary side to the vehicle battery.

Xue, Lincoln↗

Energy-Water Nexus Knowledge Discovery Framework, Experts’ Meeting Report

Energy and water generation and delivery systems are inherently interconnected. With worldwide demandfor energy growing, the energy sector is experiencing increasing competition for water. With increasingpopulation and changing environmental, socioeconomic, and demographic scenarios, new technology andinvestment decisions must be made for optimized and sustainable energy-water resource management. These decisions require novel scientific insights into the complex interdependencies of energy-water infrastructures across multiple space and time scales.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Weather Considerations for Ground-Based Optical Space Situational Awareness Site Selection

Continuous surveillance of the night sky with ground-based optical sensors requires a number of sites distributed around the globe. Due to variable cloud cover, the number of sites required to guarantee nightly observation of all Geosynchronous Earth Orbit slots is greater than that simply required to provide partial coverage. Combining this consideration with the requirements for dark sky sites and adequate supporting infrastructure presents additional limitations on where ground- based telescopes can be located. The authors examine this problem and present results of an optimization approach that can both recommend sites and networks of sites, as well as provide insight into the utility of any individual geographic location.

54 ENVIRONMENTAL SCIENCES↗

Distributed Aviation Concepts and Technologies

Aviation has experienced one hundred years of evolution, resulting in the current air transportation system dominated by commercial airliners in a hub and spoke infrastructure. While the first fifty years involved disruptive technologies that required frequent vehicle adaptation, the second fifty years produced a stable evolutionary optimization of decreasing costs with increasing safety. This optimization has resulted in traits favoring a centralized service model with high vehicle productivity and cost efficiency. However, it may also have resulted in a system that is not sufficiently robust to withstand significant system disturbances. Aviation is currently facing rapid change from issues such as environmental damage, terrorism threat, congestion and capacity limitations, and cost of energy. Currently, these issues are leading to a loss of service for weaker spoke markets. These catalysts and a lack of robustness could result in a loss of service for much larger portions of the aviation market. The impact of other competing transportation services may be equally important as casual factors of change. Highway system forecasts indicate a dramatic slow down as congestion reaches a point of non-linearly increasing delay. In the next twenty-five years, there is the potential for aviation to transform itself into a more robust, scalable, adaptive, secure, safe, affordable, convenient, efficient and environmentally friendly system. To achieve these characteristics, the new system will likely be based on a distributed model that enables more direct services. Short range travel is already demonstrating itself to be inefficient with a centralized model, providing opportunities for emergent distributed services through air-taxi models. Technologies from the on-demand revolution in computers and communications are now available as major drivers for aviation on-demand adaptation. Other technologies such as electric propulsion are currently transforming the automobile industry, and will also significantly alter the functionality of future distributed aviation concepts. Many hurdles exist, including technology, regulation, and perception. Aviation has an inherent governmental role not present in other recent on-demand transformations, which may pose a risk of curtailing aviation democratization .

Moore, Mark D.↗

Automated Work Package: Initial Wireless Communication Platform Design, Development, and Evaluation

The Department of Energy's Light Water Reactor Sustainability Program is developing the scientific basis to ensure long-term reliability, productivity, safety, and security of the nuclear power industry in the United States. The Instrumentation, Information, and Control (II and C) pathway of the program aims to increase the role of advanced II and C technologies to achieve this objective. One of the pathway efforts at Idaho National Laboratory (INL) is to improve the work packages execution process by replacing the expensive, inefficient, bulky, complex, and error-prone paper-based work orders with automated work packages (AWPs). An AWP is an automated and dynamic presentation of the work package designed to guide the user through the work process. It is loaded on a mobile device, such as a tablet, and is capable of communicating with plant equipment and systems to acquire plant and procedure states. The AWP replaces those functions where a computer is more efficient and reliable than a human. To enable the automatic acquisition of plant data, it is necessary to design and develop a prototype platform for data exchange between the field instruments and the AWP mobile devices. The development of the platform aims to reveal issues and solutions generalizable to large-scale implementation of a similar system. Topics such as bandwidth, robustness, response time, interference, and security are usually associated with wireless communication. These concerns, along with other requirements, are listed in an earlier INL report. Specifically, the targeted issues and performance aspects in this work are relevant to the communication infrastructure from the perspective of promptness, robustness, expandability, and interoperability with different technologies. The development of a prompt system entailed significant performance optimization, including the use of parallel processing, parallel communication, modularity, noise filtering, and frequency tuning. A robust system was achieved by enforcing a persistent continuous data exchange that automatically detects and conveys a failure of any link or component in any part of the system, and that automatically restores the communication once the link or component is restored. An expandable topology was enabled by modularity and load sharing. The number of servers, mobile devices, and field instruments is not limited from a system structure point of view. The system interoperability was achieved by enforcing the independence of the field communication application from the mobile device application. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Destined for indecision? A critical analysis of waste management practices in England from 1996 to 2013

Highlights: • Critical analysis of municipal waste management practices and performance in England. • Trends visualised via innovative ternary plots and changes and reasons explored. • Performance 1996–2013 moved slowly away from landfill dominance. • Large variations in %s of waste landfilled, incinerated and recycled/composted. • Progress to resource efficiency slow; affected by poor planning and hostile disputes. - Abstract: European nations are compelled to reduce reliance on landfill as a destination for household waste, and should, in principle, achieve this goal with due recognition of the aims and principles of the waste hierarchy. Past research has predominantly focused on recycling, whilst interactions between changing waste destinies, causes and drivers of household waste management change, and potential consequences for the goal of the waste hierarchy are less well understood. This study analysed Local Authority Collected Waste (LACW) for England, at national, regional and sub-regional level, in terms of the destination of household waste to landfill, incineration and recycling. Information about waste partnerships, waste management infrastructure and collection systems was collected to help identify and explain changes in waste destinies. Since 1996, the proportion of waste landfilled in England has decreased, in tandem with increases in recycling and incineration. At the regional and sub-regional (Local Authority; LA) level, there have been large variations in the relative proportions of waste landfilled, incinerated and recycled or composted. Annual increases in the proportion of household waste incinerated were typically larger than increases in the proportion recycled. The observed changes took place in the context of legal and financial drivers, and the circumstances of individual LAs (e.g. landfill capacity) also explained the changes seen. Where observed, shifts from landfill towards incineration constitute an approach whereby waste management moves up the waste hierarchy as opposed to an attempt to reach the most preferred option(s); in terms of resource efficiency, this practice is sub-optimal. The requirement to supply incinerators with a feedstock over their lifespan reduces the benefits of developing of recycling and waste reduction, although access to incineration infrastructure permits short-term and marked decreases in the proportion of LACW landfilled. We conclude that there is a need for clearer national strategy and co-ordination to inform and guide policy, practice, planning and investment in infrastructure such that waste management can be better aligned with the principles of the circular economy and resource efficiency. If the ongoing stand-off between national political figures and the waste sector continues, England’s waste policy remains destined for indecision.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Towards 5G-Enabled Operational Technology for Process Monitoring and Network Slicing

Cyber-Physical Systems (CPS) are deployed to monitor physical processes in critical cyber-enabled services like power generation. However, CPS ecosystems are typically designed without robust security. While it is important to ensure optimal performance of the Operational Technology (OT) environments, security cannot be overlooked. To modernize traditional OT services, 5G technology is being integrated. 5G technology offers low latency and high availability, making it a suitable infrastructure for managing and monitoring physical processes. How-ever, integrating 5G mechanisms into large-scale OT networks introduces new implementation and performance challenges. Therefore, this paper presents a 5G-enabled CPS architecture (5G-CPS) that describes the necessary components, services, and communication protocols and conducts feasibility study to integrate 5G technology in industrial control system networks to understand the performance merits. The 5G-CPS architecture aims to minimize implementation and operational challenges associated with integrating 5G technology into constrained OT.

Aguayo, Jared M.↗

Optimization of a Secondary Air Injector for a Rich-Quench-Lean (RQL) Ammonia Combustor Using Computational Fluid Dynamics

Ammonia has emerged as a promising medium for moving hydrogen around the globe due to its energy density, existing infrastructure for production, transportation, and storage, and multiple applications from fertilizer to power generation. However, one of the most significant challenges with ammonia combustion for power generation is the formation of nitrogen oxides (NOx) during combustion. Several combustion strategies have been developed to minimize the formation of NOx. One such strategy, known as rich-quench-lean (RQL), is a method that combusts NH3 in a fuel-rich environment, followed by a quick mix section and a lean burnout section. Rapid mixing of secondary air before lean burnout is thought to be important to minimize the formation of NOx. A genetic algorithm (GA) is used to parametrically vary the secondary air injector design, including the diameter, count, and angles over a constrained design space. The designs are evaluated using a non-reacting OpenFOAM model, with the objective function being the uniformity index of the secondary air (modeled as a scalar). Optimization campaigns show that traditional correlation-based designs might not be adequate. After running 414 OpenFOAM models, the optimal design is 32, 1 mm diameter, angled air injectors, increasing the uniformity index at the outlet of the quick mix zone by 36.8%. The most promising designs will be manufactured and tested in a small RQL burner setup, which is expected to lead to validation and insight into the practical usage of NH3 combustion for power generation.

ammonia combustion↗

Analysis of hydrogen infrastructure for the feasibility, economics, and sustainability of a fuel cell powered data center

Data centers used for internet data services, cloud computing, and/or data storage consume vast amounts of electricity and are increasing rapidly in capacity. Consequently, their power consumption has raised concerns about energy sustainability and environmental impacts. Large-scale, on-site renewable energy could help reduce data centers’ carbon footprint; however, wind and solar power alone cannot provide an uninterrupted power supply to computer servers due to their natural variability. Instead, reliable power integration can be achieved by using fuel cells powered by hydrogen from sustainable resources (e.g., wind and solar energy). Establishing a hydrogen infrastructure will be critical for realizing these benefits and establishing fuel cells as a viable power source for data centers. Here, to facilitate the development of novel carbon-free fuel cell data enters, this paper presents renewable power integrated with hydrogen infrastructures in four scenarios to provide reliable hydrogen supply from production to storage. Various paths were analyzed toward a hydrogen supply infrastructure by determining the proper component sizes and calculating the cost of meeting the server load. We used a microgrid modeling software, Hybrid Optimization of Multiple Energy Resources (HOMER), and studied the feasibility of fuel cell powered data centers employing renewable hydrogen. The modeling results show various renewable integration configurations to meet reliable and sustainable power requirement under four scenarios for a carbon-free data center.

08 HYDROGEN↗

Research and Development Priorities for Silicon Photovoltaic Module Recycling to Support a Circular Economy

Large-scale deployment of photovoltaic (PV) modules has considerably increased in recent decades. Given an estimated lifetime of 30 years, the challenge of how to handle large volumes of end-of-life PV modules is starting to emerge. In this Perspective, we assess the global status of practice and knowledge for end-of-life management for crystalline silicon PV modules. We focus in particular on module recycling, a key aspect in the circular economy of photovoltaic panels. We recommend research and development to reduce recycling costs and environmental impacts compared to disposal while maximizing material recovery. We suggest that the recovery of high-value silicon is more advantageous than the recovery of intact silicon wafers. This approach requires the identification of contaminants and the design of purification processes for recovered silicon. The environmental and economic impacts of recycling practices should be explored with techno–economic analyses and life-cycle assessments to optimize solutions and minimize trade-offs. As photovoltaic technology advances rapidly, it is important for the recycling industry to plan adaptable recycling infrastructure.

c-Si↗

CostMAP: an open-source software package for developing cost surfaces using a multi-scale search kernel

Cost surfaces are a crucial aspect of route optimization and least cost path (LCP) calculations and are used in awide range of disciplines including computer science, landscape ecology, and energy-infrastructure modeling. Linear features introduce akey weakness to traditional routing calculations along cost surfaces because they cannot identify whether moving from acell to its adjacent neighbors constitutes crossing alinear barrier (increased cost) or following acorridor (reduced cost). Following and avoiding linear features can drastically change predicted routes. We introduce an approach to address this adjacency issue using asearch kernel that determines these critical barriers and corridors. We have built this method into anew Java-based open-source software package– CostMAP (cost surface multi-layer aggregation program)– which calculates cost surfaces and cost networks using the search kernel. CostMAP allows users to input multiple GIS data layers and to set weights and rules for developing aweighted-cost network. We compare CostMAP performance with traditional cost surface approaches and show significant performance gains– both following corridors and avoiding barriers– by modeling the movement of alarge terrestrial animal– the Baird’s Tapir (Tapirus bairdii)– in amovement ecology framework and by modeling pipeline routing for carbon capture and storage (CCS).

58 GEOSCIENCES↗

Using Artificial Intelligence to Improve Reliability and Operational Efficiency of Small-Scale Hydroelectric Distributed Generation

Reliability and resilience are critical concerns for distributed generation (DG) at the rural electric level. The integration of renewable energy sources, such as small-scale hydroelectric distributed generators (hydro DGs), introduces operational challenges, particularly regarding aging infrastructure and grid stability. Artificial Intelligence (AI)-driven Machine Learning (ML) models and applications of Large Language Models (LLMs) offer promising solutions for optimizing DG operations and enhancing resilience. This paper explores AI-based models for improving efficiency, fault resolution, and outage mitigation in small-scale hydro DGs. Furthermore, it highlights the development of a centralized, AI-powered information portal for rural electric cooperatives and municipalities. The research evaluates hydro DG plant models and discusses the applicability of AI-powered question-answering tools for real-time operations, focusing on statistical data, load flow, voltage regulation, and generation power. The findings demonstrate AI’s potential to transform DG management to ensure greater stability and resilience in rural electric grids.

Bhattacharyya, Arjun [ORNL] (ORCID:000900060976046↗

Behind-the-Meter Solar Generation Disaggregation using Consumer Mixture Models

To facilitate deep penetration of solar energy in smart grids, we need high observability of solar generation at the edges of the grid. Current advanced metering infrastructures (AMI) only monitor the aggregated measurements from net-metered households, but disaggregated consumption and solar generation components are required for grid optimizations. We propose an unsupervised disaggregation model for disaggregating solar generation from AMI measurements without the need of training data. The model requires only AMI measurements from consumers in a region and the solar irradiance as input, and models the consumption of consumers by neighboring households without rooftop photovoltaics (PV) to perform the disaggregation. We evaluate our results on a real life dataset from Austin, Texas. We show that our model is able to disaggregate consumption and solar generation measurements with 42.24% and 31.67% less mean squared error, respectively, in comparison to a baseline technique that uses supervised learning. This shows that our model is capable of disaggregating historical data even if the dataset has no training data and only contains minimal exogenous data.

14 SOLAR ENERGY↗

Application of Site Controllers for Electrification of Commercial Fleet Vehicles

Electrification of transportation fleets presents a significant challenge for commercial customers. These challenges can be specific to region, weather, operating schedule, charging infrastructure, and other factors. This paper presents the value of integrating a site controller to monitor the health of assets and co-optimize the operation of commercial sites with multiple distributed energy resource technologies and electric vehicle fleets. The tests demonstrate smart-charging and vehicle-to-building uses compared to business-as-usual cases. The secondary objectives of power management for the customer vehicle are optimized by a planning tool (REopt) and integrated using the site controller. Any deviations from the planned dispatch are addressed by the real-time controllers offering tertiary controls, such as energy management, and limiting the reverse power flow (back into the grid). The results indicate that site controllers offer an efficient solution to manage the health of the connected assets and a scalable means to optimize the operations of a commercial customer with electrified transportation fleets.

ADVANCED PROPULSION SYSTEMS,POWER TRANSMISSION AND↗

Agent-Based Simulation of Price-Demand Dynamics in Multi-Service Charging Station

As the adoption of electric vehicles and hydrogen fuel-cell vehicles grows, understanding how dynamic pricing strategies influence charging and refueling behaviors becomes crucial for optimizing local energy markets. This paper proposes a simulation-based analysis of a hydrogen-electricity integrated charging station that serves both types of vehicles. A multi-agent simulation framework is developed to model the interactions between vehicles and the station, incorporating price- and delay-sensitive behaviors in decision-making. The station can dynamically adjust energy prices, while vehicles optimize their charging or refueling choices based on their utility values. A series of sensitivity analyses are conducted to evaluate how electricity pricing, infrastructure capacity, and waiting behavior impact station performance. Results highlight that moderate electricity prices maximize user participation without sacrificing profit, infrastructure should be right-sized to demand to avoid over- or underutilization, and delay-toleration also affects service outcomes, which may reach the maximum service coverage at the threshold of 45 minutes.

Wang, Xudong [University of Tennessee, Knoxville (↗

Enabling a Physical Twin for Control Methods Evaluation

Advanced nuclear reactors play an important role in the energy future of the United States and the rest of the world. They are designed and operated based on a different model than that of the current operating fleet, thus enabling deployment in remote locations and allowing for safe semi-autonomous or autonomous operations. Such characteristics require the development of a new reactor control paradigm. A significant factor in the development of control technologies and methods is integration of the various technologies and methods with each other and with hardware (both reactor system hardware and control hardware). A recent workshop on control of advanced reactors identified the lack of a flexible, expandable software/hardware infrastructure to enable such integration as a key gap. A previous phase of the current effort involved developing and demonstrating the Control and Optimization Modular Modeling Application for Nuclear Deployment (COMMAND) platform, which is capable of integrating autonomous-control-enabling technologies and methods, without the constraints imposed by existing software solutions. This platform will enable advanced reactor developers to deploy and test any developed technologies and methods by employing a common framework, and to couple them with their own models and hardware. The present phase of this effort entails using the Microreactor Automated Control System (MACS) platform, which was developed by the U.S. Department of Energy (DOE) Microreactor Program, to serve as a control method testbed. MACS can be used by advanced reactor developers to integrate their control related research activities with any reactor system. For the present effort, MACS was customized to mirror Idaho National Laboratory (INL)’s Microreactor Applications Research Validation and Evaluation (MARVEL) microreactor, and COMMAND was leveraged to enable MACS to emulate the physics of MARVEL, thus positioning MACS as a physical twin of MARVEL.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

NREL Price Series Developed for the ARPA-E FLECCS Program

The price data for four regions (CAISO, ERCOT, MISO-W, and PJM-W) are developed using the ReEDS to PLEXOS conversion as described in (Gagnon et al. 2020). The reference ReEDS case chosen is based on the 2020 Standard Scenario Mid-case, which uses the 2020 ReEDS model version (Cole et al. 2020; Ho et al. 2021). All ReEDS model inputs use 2020 Standard Scenarios Mid-case assumptions except for CO2 prices, which are implemented as linearly increasing CO2 price trajectories beginning at $0/tCO2 in 2020 and ending at either $100/tCO2 or $150/tCO2 in 2035 to dive capacity expansion towards a low-carbon system that could support CCS deployment. However, these scenarios also prohibit CCS deployment in this time frame so that resulting price data are not influenced by the deployment and operation of CCS itself. Implementing the ReEDS to PLEXOS conversion tool, PLEXOS is then simulated using the 2035 ReEDS infrastructure for both CO2 price scenarios, with the following model version and setup: PLEXOS Version: 8.2 Solver: Xpress-MP 35.01.01 Mixed integer optimization relative gap 1% System configuration: • Total number of nodes: 134 (consistent with ReEDS balancing areas) • Line losses enforced using piecewise linear approximation • Energy dump was enabled Price data is aggregated to the ISO/RTO level using load-weighted averages. References: Cole, Wesley, Sean Corcoran, Nathaniel Gates, Daniel Mai, Trieu, and Paritosh Das. 2020. “2020 Standard Scenarios Report: A U.S. Electricity Sector Outlook.” NREL/TP-6A20-77442. Golden, CO: National Renewable Energy Laboratory. https://www.nrel.gov/docs/fy21osti/77442.pdf. Gagnon, Pieter, Will Frazier, Elaine Hale, and Wesley Cole. 2020. “Cambium Documentation: Version 2020.” NREL/TP-6A20-78239. National Renewable Energy Lab. (NREL), Golden, CO (United States). https://doi.org/10.2172/1734551. Ho, Jonathan, Jonathon Becker, Maxwell Brown, Patrick Brown, Ilya (ORCID:0000000284917814) Chernyakhovskiy, Stuart Cohen, Wesley (ORCID:000000029194065X) Cole, et al. 2021. “Regional Energy Deployment System (ReEDS) Model Documentation: Version 2020.” NREL/TP-6A20-78195. Golden, CO: National Renewable Energy Laboratory. https://doi.org/10.2172/1788425.

24 POWER TRANSMISSION AND DISTRIBUTION↗