Search NASA⌕ Search

SEARCH · Search NASA

Results for “parameter selection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

The effect of pellet injection on turbulent transport in TJ-II

An improvement in confinement associated with the injection of pellets has been observed in TJ-II and other devices. By means of a simple model, we study here the modification of turbulent transport by the injection of pellets in TJ-II and how this modification affects the particle confinement time. The analysis of the results shows the relationship of the confinement improvement with the evolution of the shear flow due to turbulence, especially near low order rational surfaces. This work is based on pellet injections into the neutral beam injection heated phase of TJ-II plasmas. For this, single, double, or triple hydrogen pellet injection are considered and the post-injection evolution of selected plasma parameters are analyzed and compared.

Physics↗

Quantum dot polarisation converter in an optomechanical cavity

We propose a scheme of a quantum photon polarisation converter, which is based on controlled electron – photon – phonon transitions in a hybrid semiconductor nanostructure. This structure consists of a GaAs/InAs quantum dot (QD) that has a parallelepiped shape and contains a single electron, and an optomechanical microcavity (MC) based on a photonic crystal (PC) that supports two orthogonally polarised photonic modes and one mechanical (phonon) mode. Within the framework of the microscopic theory, the QD and MC performance characteristics are found. Populations of states of the system as functions of time and its parameters are calculated. The principal possibility of photon polarisation conversion using transitions in a five-level resonance scheme for coherent (single-photon) and steady-state (subphoton) regimes is shown. The MC optical and mechanical spectra are simulated, and the PC structure parameters are selected to ensure the efficient operation of the converter. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Features of multilayer mirror application for focusing and collimating X-rays from inverse Compton scattering sources

We have analysed the use of X-ray interference multilayer mirrors as the elements of a focusing scheme for a compact source based on inverse Compton scattering. An algorithm is proposed for selecting mirror parameters, which takes into account the properties of the radiation source. The dependence of wavelength on the viewing angle and the energy line broadening for a fixed viewing angle are found to be the main limitations in the use of multilayer mirrors. Efficient radiation collection calls for the application of broadband mirrors. It is shown that the efficiency of multilayer mirrors in a Kirkpatrick – Baez X-ray focusing setup exceeds that of total external reflection mirrors by an order of magnitude, and that stack multilayer mirrors offer a small advantage over the periodic ones. The overall efficiency of source radiation collection in the photon energy range ΔE = 10 – 12 keV amounts to 12 % for the two-mirror Kirkpatrick – Baez setup. For a spectral region with a bandwidth ΔE/E = 3 %, the efficiency ranges up to 69 %. (paper)

07 ISOTOPE AND RADIATION SOURCES↗

Hybrid Parameter Search and Dynamic Model Selection for Mixed-Variable Bayesian Optimization

Herein this article presents a new type of hybrid model for Bayesian optimization (BO) adept at managing mixed variables, encompassing both quantitative (continuous and integer) and qualitative (categorical) types. Our proposed new hybrid models (named hybridM) merge the Monte Carlo Tree Search structure (MCTS) for categorical variables with Gaussian Processes (GP) for continuous ones. hybridM leverages the upper confidence bound tree search (UCTS) for MCTS strategy, showcasing the tree architecture’s integration into Bayesian optimization. Our innovations, including dynamic online kernel selection in the surrogate modeling phase and a unique UCTS search strategy, position our hybrid models as an advancement in mixed-variable surrogate models. Numerical experiments underscore the superiority of hybrid models, highlighting their potential in Bayesian optimization.

97 MATHEMATICS AND COMPUTING↗

COMPACT DUST CONCENTRATION IN THE MWC 758 PROTOPLANETARY DISK

The formation of planetesimals requires that primordial dust grains grow from micron- to kilometer-sized bodies. Dust traps caused by gas pressure maxima have been proposed as regions where grains can concentrate and grow fast enough to form planetesimals, before radially migrating onto the star. We report new VLA Ka and Ku observations of the protoplanetary disk around the Herbig Ae/Be star MWC 758. The Ka image shows a compact emission region in the outer disk, indicating a strong concentration of big dust grains. Tracing smaller grains, archival ALMA data in band 7 continuum shows extended disk emission with an intensity maximum to the northwest of the central star, which matches the VLA clump position. The compactness of the Ka emission is expected in the context of dust trapping, as big grains are trapped more easily than smaller grains in gas pressure maxima. We develop a nonaxisymmetric parametric model inspired by a steady-state vortex solution with parameters adequately selected to reproduce the observations, including the spectral energy distribution. Finally, we compare the radio continuum with SPHERE scattered light data. The ALMA continuum spatially coincides with a spiral-like feature seen in scattered light, while the VLA clump is offset from the scattered light maximum. Moreover, the ALMA map shows a decrement that matches a region devoid of scattered polarized emission. Continuum observations at a different wavelength are necessary to conclude whether the VLA-ALMA difference is an opacity or a real dust segregation.

79 ASTRONOMY AND ASTROPHYSICS↗

Conceptual design of a hybrid neutron-gamma detector for study of β-delayed neutrons at the RIB facility of RIKEN

Here, the conceptual design of the BRIKEN neutron detector at the radioactive ion beam factory (RIBF) of the RIKEN Nishina Center is reported. The BRIKEN setup is a complex system aimed at detecting heavy-ion implants, β particles, γ rays and β-delayed neutrons. The whole setup includes the Advanced Implantation Detection Array (AIDA), two HPGe Clover detectors and up to 166 3 He-filled counters embedded in a high-density polyethylene moderator. The design is quite complex due to the large number and different types of 3 He-tubes involved and the additional constraints introduced by the ancillary detectors for charged particles and γ rays. This article reports on a novel methodology developed for the conceptual design and optimisation of the 3 He-counter array, aiming for the best possible performance in terms of neutron detection. The algorithm is based on a geometric representation of two selected detector parameters of merit, namely, the average neutron detection efficiency and the efficiency flatness as a function of a reduced number of geometric variables. The response of the neutron detector is obtained from a systematic Monte Carlo simulation implemented in GEANT4. The robustness of the algorithm allowed us to design a versatile detection system, which operated in hybrid mode includes the full neutron counter and two clover detectors for high-precision gamma spectroscopy. In addition, the system can be reconfigured into a compact mode by removing the clover detectors and re-arranging the 3 He tubes in order to maximize the neutron detection performance. Both operation modes shows a rather flat and high average efficiency. In summary, we have designed a system which shows an average efficiency for hybrid mode ( 3 He tubes + clovers) of 68.6% and 64% for neutron energies up to 1 and 5 MeV, respectively. For compact mode (only 3 He tubes), the average efficiency is 75.7% and 71% for neutron energies up to 1 and 5 MeV, respectively. The performance of the BRIKEN detection system has been also quantified by means of Monte Carlo simulations with different neutron energy distributions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The possibility of anesthesia stimulated by a train of current pulses

This study considers a simple theoretical model of blocking the passage of signals (action potentials) from sensory neurons, thereby affecting anesthesia without the use of anesthetics as a result of a sequence of unipolar current pulses generated by an external source. The proposed model allows the selection of parameters and the required frequency of the repetition of current pulses for the possible implementation of anesthesia, depending on the electrical characteristics of the skin and the conductivity of the saline solution in which the myelinated nerve fibers are located.

59 BASIC BIOLOGICAL SCIENCES↗

Dynamics of pion production in heavy-ion collisions around 1A GeV energies

Within the framework of the improved isospin-dependent quantum molecular dynamics model, the dynamics of pion emission in heavy-ion collisions in the region of 1A GeV energies as a probe of nuclear symmetry energy at suprasaturation densities is investigated systematically. The total pion multiplicities and the {pi}{sup -}/{pi}{sup +} yields are calculated for selected Skyrme parameters SkP, SLy6, Ska, and SIII and also for the cases of different stiffness of symmetry energy with the parameter SLy6. The influence of Coulomb potential, symmetry energy, and in-medium pion potential on the pion production is investigated and compared to each other by analyzing the distributions of transverse momentum and longitudinal rapidity and also the excitation functions of the total pion and the {pi}{sup -}/{pi}{sup +} ratio. The directed flow, elliptic flow, and polar-angle distributions are calculated for the cases of different collision centralities and also the various stiffnesses of the symmetry energies. A comparison of the calculations with the available experimental data is performed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Constraining the high-density behavior of the nuclear equation of state from strangeness production in heavy-ion collisions

The dynamics of pions and strange particles in heavy-ion collisions in the region of 1A GeV energies is investigated by the lanzhou quantum molecular dynamics model for probing the nuclear equation of state at suprasaturation densities. The total multiplicities and the ratios obtained in {sup 197}Au+{sup 197}Au over {sup 12}C+{sup 12}C systems are calculated for selected Skyrme parameters SkP, SLy6, Ska, and SIII, which correspond to different modulus of incompressibility of symmetric nuclear matter and different cases of the stiffness of symmetry energy. A decreasing trend of the excitation functions of the ratios for strange particle production with increasing incident energy was observed. The available data of K{sup +} production measured by KaoS collaboration are described well with the parameter SkP, which results in a soft equation of state. The conclusions cannot be modified by an in-medium kaon-nucleon potential.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Pair distribution function analysis of discrete nanomaterials in PDFgui

Pair distribution functions (PDFs) are a leading tool for atomic structure analysis of nanomaterials. However, the most widely used programs for refining atomic structure against PDF data are based on extended crystallographic models, which cannot be applied to discrete, whole nanoparticles. Furthermore, this work describes a straightforward approach to simulate and refine atomistic models of discrete clusters and nanoparticles employing widely used PDF modelling programs such as PDFgui that utilize extended crystallographic models. In this approach, the whole particle to be modelled is contained within an expanded, and otherwise empty, unit cell that is sufficiently large to avoid correlations between atoms in neighbouring unit cells over the r range analyzed. The PDF of the particle is simulated as a composite using two conventional `phases': one that calculates the atom–atom correlations and one that approximates the local number density. This approach is first validated for large nanoparticles that are well modelled by a conventional shape factor model, and then applied to simulate the PDF of discrete particles and low-dimensional materials (graphene and MXene) and to model the experimental PDF data for single-layer FeS nanosheets. A comparison of this approach with the DiffPy-CMI program, which calculates the PDF of discrete species, shows that the composite modelling approach is equally or more accurate. Example input files for implementing this approach within PDFgui and TOPAS, and recommendations for selecting model parameters for reliable application of this refinement strategy, are provided.

36 MATERIALS SCIENCE↗

A simple solution to the Rietveld refinement recipe problem

Rietveld refinements are widely used for many purposes in the physical sciences. Conducting a Rietveld refinement typically requires expert input because correct results may require that parameters be added to the fit in the proper order. This order will depend on the nature of the data and the initial parameter values. A mechanism for computing the next parameter to add to the refinement is shown. The fitting function is evaluated with the current parameter value set and each parameter incremented and decremented by a small offset. This provides the partial derivatives with respect to each parameter, along with information to discriminate meaningful values from numerical computational errors. The implementation of this mechanism in the open-source GSAS-II program is discussed. This new method is discussed as an important step towards the development of automated Rietveld refinement technology.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Metric Learning to Accelerate Convergence of Operator Splitting Methods

Recent developments in machine learning have led to promising advances in accelerating the solution of constrained optimization problems. Increasing demand for real-time decision-making capabilities in applications such as artificial intelligence and optimal control has led to a variety of proposed strategies for learning to produce fast solutions to optimization problems. For example, recent works have shown that it is possible to accelerate the convergence of optimization algorithms by learning to select their parameters, such as gradient descent stepsizes. This work proposes a new approach, in which the underlying metric spaces of proximal operator splitting algorithms are learned to maximize convergence rate. While prior works in optimization theory have derived optimal metrics in simple cases, no such result exists for many practical problem forms including general Quadratic Programming (QP). This paper shows how differentiable optimization can enable the end-to-end learning of proximal metrics, enhancing the convergence of proximal algorithms for QP problems beyond what is possible based on known theory. Additionally, the results illustrate a strong connection between the learned proximal metrics and active constraints at the optima, leading to an interpretation in which the predicted proximal metrics can be viewed as a form of active set prediction.

King, Ethan [BATTELLE (PACIFIC NW LAB)]↗

Examination of a Size-Change Test for Photovoltaic Encapsulation Materials: Preprint

We examine a proposed test standard that can be used to evaluate the maximum representative change in linear dimensions of sheet encapsulation products for photovoltaic modules (resulting from their thermal processing). The proposed protocol is part of a series of material-level tests being developed within Working Group 2 of the Technical Committee 82 of the International ElectrotechnicalCommission. The characterization tests are being developed to aid module design (by identifying the essential characteristics that should be communicated on a datasheet), quality control (via internal material acceptance and process control), and failure analysis. Discovery and interlaboratory experiments were used to select particular parameters for the size-change test. The choice of a sandsubstrate and aluminum carrier is explored relative to other options. The temperature uniformity of +/- 5C for the substrate was confirmed using thermography. Considerations related to the heating device (hot-plate or oven) are explored. The time duration of 5 minutes was identified from the time-series photographic characterization of material specimens (EVA, ionomer, PVB, TPO, and TPU). Thetest procedure was revised to account for observed effects of size and edges. The interlaboratory study identified typical size-change characteristics, and also verified the absolute reproducibility of +/- 5% between laboratories.

14 SOLAR ENERGY↗

The feasibility of a scanner-independent technique to estimate organ dose from MDCT scans: Using CTDI{sub vol} to account for differences between scanners

Purpose: Monte Carlo radiation transport techniques have made it possible to accurately estimate the radiation dose to radiosensitive organs in patient models from scans performed with modern multidetector row computed tomography (MDCT) scanners. However, there is considerable variation in organ doses across scanners, even when similar acquisition conditions are used. The purpose of this study was to investigate the feasibility of a technique to estimate organ doses that would be scanner independent. This was accomplished by assessing the ability of CTDI{sub vol} measurements to account for differences in MDCT scanners that lead to organ dose differences. Methods: Monte Carlo simulations of 64-slice MDCT scanners from each of the four major manufacturers were performed. An adult female patient model from the GSF family of voxelized phantoms was used in which all ICRP Publication 103 radiosensitive organs were identified. A 120 kVp, full-body helical scan with a pitch of 1 was simulated for each scanner using similar scan protocols across scanners. From each simulated scan, the radiation dose to each organ was obtained on a per mA s basis (mGy/mA s). In addition, CTDI{sub vol} values were obtained from each scanner for the selected scan parameters. Then, to demonstrate the feasibility of generating organ dose estimates from scanner-independent coefficients, the simulated organ dose values resulting from each scanner were normalized by the CTDI{sub vol} value for those acquisition conditions. Results: CTDI{sub vol} values across scanners showed considerable variation as the coefficient of variation (CoV) across scanners was 34.1%. The simulated patient scans also demonstrated considerable differences in organ dose values, which varied by up to a factor of approximately 2 between some of the scanners. The CoV across scanners for the simulated organ doses ranged from 26.7% (for the adrenals) to 37.7% (for the thyroid), with a mean CoV of 31.5% across all organs. However, when organ doses are normalized by CTDI{sub vol} values, the differences across scanners become very small. For the CTDI{sub vol}, normalized dose values the CoVs across scanners for different organs ranged from a minimum of 2.4% (for skin tissue) to a maximum of 8.5% (for the adrenals) with a mean of 5.2%. Conclusions: This work has revealed that there is considerable variation among modern MDCT scanners in both CTDI{sub vol} and organ dose values. Because these variations are similar, CTDI{sub vol} can be used as a normalization factor with excellent results. This demonstrates the feasibility of establishing scanner-independent organ dose estimates by using CTDI{sub vol} to account for the differences between scanners.

61 RADIATION PROTECTION AND DOSIMETRY↗

An adaptive regularization parameter choice strategy for multispectral bioluminescence tomography

Purpose: Bioluminescence tomography (BLT) provides an effective tool for monitoring physiological and pathological activities in vivo. However, the measured data in bioluminescence imaging are corrupted by noise. Therefore, regularization methods are commonly used to find a regularized solution. Nevertheless, for the quality of the reconstructed bioluminescent source obtained by regularization methods, the choice of the regularization parameters is crucial. To date, the selection of regularization parameters remains challenging. With regards to the above problems, the authors proposed a BLT reconstruction algorithm with an adaptive parameter choice rule. Methods: The proposed reconstruction algorithm uses a diffusion equation for modeling the bioluminescent photon transport. The diffusion equation is solved with a finite element method. Computed tomography (CT) images provide anatomical information regarding the geometry of the small animal and its internal organs. To reduce the ill-posedness of BLT, spectral information and the optimal permissible source region are employed. Then, the relationship between the unknown source distribution and multiview and multispectral boundary measurements is established based on the finite element method and the optimal permissible source region. Since the measured data are noisy, the BLT reconstruction is formulated as l{sub 2} data fidelity and a general regularization term. When choosing the regularization parameters for BLT, an efficient model function approach is proposed, which does not require knowledge of the noise level. This approach only requests the computation of the residual and regularized solution norm. With this knowledge, we construct the model function to approximate the objective function, and the regularization parameter is updated iteratively. Results: First, the micro-CT based mouse phantom was used for simulation verification. Simulation experiments were used to illustrate why multispectral data were used rather than monochromatic data. Furthermore, the study conducted using an adaptive regularization parameter demonstrated our ability to accurately localize the bioluminescent source. With the adaptively estimated regularization parameter, the reconstructed center position of the source was (20.37, 31.05, 12.95) mm, and the distance to the real source was 0.63 mm. The results of the dual-source experiments further showed that our algorithm could localize the bioluminescent sources accurately. The authors then presented experimental evidence that the proposed algorithm exhibited its calculated efficiency over the heuristic method. The effectiveness of the new algorithm was also confirmed by comparing it with the L-curve method. Furthermore, various initial speculations regarding the regularization parameter were used to illustrate the convergence of our algorithm. Finally, in vivo mouse experiment further illustrates the effectiveness of the proposed algorithm. Conclusions: Utilizing numerical, physical phantom and in vivo examples, we demonstrated that the bioluminescent sources could be reconstructed accurately with automatic regularization parameters. The proposed algorithm exhibited superior performance than both the heuristic regularization parameter choice method and L-curve method based on the computational speed and localization error.

61 RADIATION PROTECTION AND DOSIMETRY↗

Evaluation of a semiautomated lung mass calculation technique for internal dosimetry applications

Purpose: The authors sought to evaluate a simple, semiautomated lung mass estimation method using computed tomography (CT) scans obtained using a variety of acquisition techniques and reconstruction parameters for mass correction of medical internal radiation dose-based internal radionuclide radiation absorbed dose estimates.Methods: CT scans of 27 patients with lung cancer undergoing stereotactic body radiation therapy treatment planning with PET/CT were analyzed retrospectively. For each patient, free-breathing (FB) and respiratory-gated 4DCT scans were acquired. The 4DCT scans were sorted into ten respiratory phases, representing one complete respiratory cycle. An average CT reconstruction was derived from the ten-phase reconstructions. Mid expiration breath-hold CT scans were acquired in the same session for many patients. Deep inspiration breath-hold diagnostic CT scans of many of the patients were obtained from different scanning sessions at similar time points to evaluate the effect of contrast administration and maximum inspiration breath-hold. Lung mass estimates were obtained using all CT scan types, and intercomparisons made to assess lung mass variation according to scan type. Lung mass estimates using the FB CT scans from PET/CT examinations of another group of ten male and ten female patients who were 21–30 years old and did not have lung disease were calculated and compared with reference lung mass values. To evaluate the effect of varying CT acquisition and reconstruction parameters on lung mass estimation, an anthropomorphic chest phantom was scanned and reconstructed with different CT parameters. CT images of the lungs were segmented using the OsiriX MD software program with a seed point of about −850 HU and an interval of 1000. Lung volume, and mean lung, tissue, and air HUs were recorded for each scan. Lung mass was calculated by assuming each voxel was a linear combination of only air and tissue. The specific gravity of lung volume was calculated using the formula (lung HU − air HU)/(tissue HU − air HU), and mass = specific gravity × total volume × 1.04 g/cm{sup 3}.Results: The range of calculated lung masses was 0.51–1.29 kg. The average male and female lung masses during FB CT were 0.80 and 0.71 kg, respectively. The calculated lung mass varied across the respiratory cycle but changed to a lesser degree than did lung volume measurements (7.3% versus 15.4%). Lung masses calculated using deep inspiration breath-hold and average CT were significantly larger (p < 0.05) than were some masses calculated using respiratory-phase and FB CT. Increased voxel size and smooth reconstruction kernels led to high lung mass estimates owing to partial volume effects.Conclusions: Organ mass correction is an important component of patient-specific internal radionuclide dosimetry. Lung mass calculation necessitates scan-based density correction to account for volume changes owing to respiration. The range of lung masses in the authors’ patient population represents lung doses for the same absorbed energy differing from 25% below to 64% above the dose found using reference phantom organ masses. With proper management of acquisition parameters and selection of FB or midexpiration breath hold scans, lung mass estimates with about 10% population precision may be achieved.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

TU-C-BRE-08: IMRT QA: Selecting Meaningful Gamma Criteria Based On Error Detection Sensitivity

Purpose: To develop a strategy for defining meaningful tolerance limits and studying the sensitivity of IMRT QA gamma criteria by inducing known errors in QA plans. Methods: IMRT QA measurements (ArcCHECK, Sun Nuclear) were compared to QA plan calculations with induced errors. Many (>24) gamma comparisons between data and calculations were performed for each of several kinds of cases and classes of induced error types with varying magnitudes (e.g. MU errors ranging from -10% to +10%), resulting in over 3,000 comparisons. Gamma passing rates for each error class and case were graphed against error magnitude to create error curves in order to represent the range of missed errors in routine IMRT QA using various gamma criteria. Results: This study demonstrates that random, case-specific, and systematic errors can be detected by the error curve analysis. Depending on location of the peak of the error curve (e.g., not centered about zero), 3%/3mm threshold=10% criteria may miss MU errors of up to 10% and random MLC errors of up to 5 mm. Additionally, using larger dose thresholds for specific devices may increase error sensitivity (for the same X%/Ymm criteria) by up to a factor of two. This analysis will allow clinics to select more meaningful gamma criteria based on QA device, treatment techniques, and acceptable error tolerances. Conclusion: We propose a strategy for selecting gamma parameters based on the sensitivity of gamma criteria and individual QA devices to induced calculation errors in QA plans. Our data suggest large errors may be missed using conventional gamma criteria and that using stricter criteria with an increased dose threshold may reduce the range of missed errors. This approach allows quantification of gamma criteria sensitivity and is straightforward to apply to other combinations of devices and treatment techniques.

60 APPLIED LIFE SCIENCES↗

WE-G-18A-01: JUNIOR INVESTIGATOR WINNER - Low-Dose C-Arm Cone-Beam CT with Model-Based Image Reconstruction for High-Quality Guidance of Neurosurgical Intervention

Purpose: To address the challenges of image quality, radiation dose, and reconstruction speed in intraoperative cone-beam CT (CBCT) for neurosurgery by combining model-based image reconstruction (MBIR) with accelerated algorithmic and computational methods. Methods: Preclinical studies involved a mobile C-arm for CBCT imaging of two anthropomorphic head phantoms that included simulated imaging targets (ventricles, soft-tissue structures/bleeds) and neurosurgical procedures (deep brain stimulation (DBS) electrode insertion) for assessment of image quality. The penalized likelihood (PL) framework was used for MBIR, incorporating a statistical model with image regularization via an edgepreserving penalty. To accelerate PL reconstruction, the ordered-subset, separable quadratic surrogates (OS-SQS) algorithm was modified to incorporate Nesterov's method and implemented on a multi-GPU system. A fair comparison of image quality between PL and conventional filtered backprojection (FBP) was performed by selecting reconstruction parameters that provided matched low-contrast spatial resolution. Results: CBCT images of the head phantoms demonstrated that PL reconstruction improved image quality (∼28% higher CNR) even at half the radiation dose (3.3 mGy) compared to FBP. A combination of Nesterov's method and fast projectors yielded a PL reconstruction run-time of 251 sec (cf., 5729 sec for OS-SQS, 13 sec for FBP). Insertion of a DBS electrode resulted in severe metal artifact streaks in FBP reconstructions, whereas PL was intrinsically robust against metal artifact. The combination of noise and artifact was reduced from 32.2 HU in FBP to 9.5 HU in PL, thereby providing better assessment of device placement and potential complications. Conclusion: The methods can be applied to intraoperative CBCT for guidance and verification of neurosurgical procedures (DBS electrode insertion, biopsy, tumor resection) and detection of complications (intracranial hemorrhage). Significant improvement in image quality, dose reduction, and reconstruction time of ∼4 min will enable practical deployment of low-dose C-arm CBCT within the operating room. AAPM Research Seed Funding (2013-2014); NIH Fellowship F32EB017571; Siemens Healthcare (XP Division)

60 APPLIED LIFE SCIENCES↗