Search NASA⌕ Search

SEARCH · Search NASA

Results for “phantom”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Poster — Thur Eve — 17: In-phantom and Fluence-based Measurements for Quality Assurance of Volumetric-driven Adaptation of Arc Therapy

During volumetric modulated arc therapy (VMAT) of head and neck cancer, some patients lose weight which may result in anatomical deviations from the initial plan. If these deviations are substantial a new treatment plan can be designed for the remainder of treatment (i.e., adaptive planning). Since the adaptive treatment process is resource intensive, one possible approach to streamlining the quality assurance (QA) process is to use the electronic portal imaging device (EPID) to measure the integrated fluence for the adapted plans instead of the currently-used ArcCHECK device (Sun Nuclear). Although ArcCHECK is recognized as the clinical standard for patient-specific VMAT plan QA, it has limited length (20 cm) for most head and neck field apertures and has coarser detector spacing than the EPID (10 mm vs. 0.39 mm). In this work we compared measurement of the integrated fluence using the EPID with corresponding measurements from the ArcCHECK device. In the past year nine patients required an adapted plan. Each of the plans (the original and adapted) is composed of two arcs. Routine clinical QA was performed using the ArcCHECK device, and the same plans were delivered to the EPID (individual arcs) in integrated mode. The dose difference between the initial plan and adapted plan was compared for ArcCHECK and EPID. In most cases, it was found that the EPID is more sensitive in detecting plan differences. Therefore, we conclude that EPID provides a viable alternative for QA of the adapted head and neck plans and should be further explored.

60 APPLIED LIFE SCIENCES↗

Feasibility of RACT for 3D dose measurement and range verification in a water phantom

Purpose: The objective of this study is to establish the feasibility of using radiation-induced acoustics to measure the range and Bragg peak dose from a pulsed proton beam. Simulation studies implementing a prototype scanner design based on computed tomographic methods were performed to investigate the sensitivity to proton range and integral dose. Methods: Derived from thermodynamic wave equation, the pressure signals generated from the dose deposited from a pulsed proton beam with a 1 cm lateral beam width and a range of 16, 20, and 27 cm in water using Monte Carlo methods were simulated. The resulting dosimetric images were reconstructed implementing a 3D filtered backprojection algorithm and the pressure signals acquired from a 71-transducer array with a cylindrical geometry (30 × 40 cm) rotated over 2π about its central axis. Dependencies on the detector bandwidth and proton beam pulse width were performed, after which, different noise levels were added to the detector signals (using 1 μs pulse width and a 0.5 MHz cutoff frequency/hydrophone) to investigate the statistical and systematic errors in the proton range (at 20 cm) and Bragg peak dose (of 1 cGy). Results: The reconstructed radioacoustic computed tomographic image intensity was shown to be linearly correlated to the dose within the Bragg peak. And, based on noise dependent studies, a detector sensitivity of 38 mPa was necessary to determine the proton range to within 1.0 mm (full-width at half-maximum) (systematic error < 150 μm) for a 1 cGy Bragg peak dose, where the integral dose within the Bragg peak was measured to within 2%. For existing hydrophone detector sensitivities, a Bragg peak dose of 1.6 cGy is possible. Conclusions: This study demonstrates that computed tomographic scanner based on ionizing radiation-induced acoustics can be used to verify dose distribution and proton range with centi-Gray sensitivity. Realizing this technology into the clinic has the potential to significantly impact beam commissioning, treatment verification during particle beam therapy and image guided techniques.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-J-53: A Phantom Design to Assist Patient Position Verification System in Daily Image-Guided RT and Comprehensive QA Measurements

Purpose This study is to implement a homemade novel device with surface locking couch index to check daily radiograph (DR) function of adaPTInsight™, stereoscopic image guided system (SIGS), for proton therapy. The comprehensive daily QA checks of proton pencil beam output, field size, flatness and symmetry of spots and energy layers will be followed by using MatriXX dosimetry device. Methods The iBa MatriXX device was used to perform daily dosimetry which is also used to perform SIGS checks. A set of markers were attached to surface of MatriXX device in alignment of DRR of reconstructed CT images and daily DR. The novel device allows MatriXX to be fit into the cradle which was locked by couch index bars on couch surface. This will keep the MatriXX at same XY plane daily with exact coordinates. Couch height Z will be adjusted according to imaging to check isocenter-laser coincidence accuracy. Results adaPTInsight™ provides robotic couch to move in 6-degree coordinate system to align the dosimetry device to be within 1.0 mm / 1.0°. The daily constancy was tightened to be ± 0.5 mm / 0.3° compared to 1.0 mm / 1.0° before. For gantry at 0° and couch all 0° angles (@ Rt ARM 0 setting), offsets measured of the couch systems were ≤ 0.5° in roll, yaw and pitch dimensions. Conclusion Simplicity of novel device made daily image guided QA consistent with accuracy. The offset of the MatriXX isocenter-laser coincident was reproducible. Such easy task not only speeds up the setup, but it increases confidence level in detailed daily comprehensive measurements. The total SIGS alignment time has been shortened with less setup error. This device will enhance our experiences for the future QA when cone beam CT imaging modality becomes available at proton therapy center.

60 APPLIED LIFE SCIENCES↗

Monte Carlo simulations of {sup 3}He ion physical characteristics in a water phantom and evaluation of radiobiological effectiveness

Purpose: {sup 3}He ions may hold great potential for clinical therapy because of both their physical and biological properties. In this study, the authors investigated the physical properties, i.e., the depth-dose curves from primary and secondary particles, and the energy distributions of helium ({sup 3}He) ions. A relative biological effectiveness (RBE) model was applied to assess the biological effectiveness on survival of multiple cell lines. Methods: In light of the lack of experimental measurements and cross sections, the authors used Monte Carlo methods to study the energy deposition of {sup 3}He ions. The transport of {sup 3}He ions in water was simulated by using three Monte Carlo codes—FLUKA, GEANT4, and MCNPX—for incident beams with Gaussian energy distributions with average energies of 527 and 699 MeV and a full width at half maximum of 3.3 MeV in both cases. The RBE of each was evaluated by using the repair-misrepair-fixation model. In all of the simulations with each of the three Monte Carlo codes, the same geometry and primary beam parameters were used. Results: Energy deposition as a function of depth and energy spectra with high resolution was calculated on the central axis of the beam. Secondary proton dose from the primary {sup 3}He beams was predicted quite differently by the three Monte Carlo systems. The predictions differed by as much as a factor of 2. Microdosimetric parameters such as dose mean lineal energy (y{sub D}), frequency mean lineal energy (y{sub F}), and frequency mean specific energy (z{sub F}) were used to characterize the radiation beam quality at four depths of the Bragg curve. Calculated RBE values were close to 1 at the entrance, reached on average 1.8 and 1.6 for prostate and head and neck cancer cell lines at the Bragg peak for both energies, but showed some variations between the different Monte Carlo codes. Conclusions: Although the Monte Carlo codes provided different results in energy deposition and especially in secondary particle production (most of the differences between the three codes were observed close to the Bragg peak, where the energy spectrum broadens), the results in terms of RBE were generally similar.

61 RADIATION PROTECTION AND DOSIMETRY↗

The Acceptability of Iterative Reconstruction Algorithms in Head CT: An Assessment of Sinogram Affirmed Iterative Reconstruction (SAFIRE) vs. Filtered Back Projection (FBP) Using Phantoms

Computed tomography (CT) is the primary imaging investigation for many neurologic conditions with a proportion of patients incurring cumulative doses. Iterative reconstruction (IR) allows dose optimization, but head CT presents unique image quality complexities and may lead to strong reader preferences.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The phantom menace of dynamic soft-shorts in solid-state battery research

Solid-state batteries with lithium metal anodes present the highest energy density batteries for applications in electric vehicles, leading to massive R&D investments over the past decade. Although most research focuses on preventing lithium metal dendrites that eventually short the battery, the nature of these shorts remains elusive. Soft-shorts, in particular, receive little attention or are not recognized, even in published data. Here, in this study, we present a comprehensive outline of the detection and analysis of soft -shorts in solid-state lithium metal cells with composite polymer electrolytes as well as a fundamental understanding of the dynamics of soft -shorts. Transient un-shorting of soft -shorts that occurs on the micro-to-millisecond timescale-driven by joule heating, chemical reactivity, and other processes-limits one's ability to determine whether the cell was or is still shorted. We provide numerous experimental methods to detect and analyze soft-shorts in any battery type as a resource to all battery researchers.

25 ENERGY STORAGE↗

On the Formation of Phantom Electron Phase Space Density Peaks in Single Spacecraft Radiation Belt Data

This study examines the rapid losses and acceleration of trapped relativistic and ultrarelativistic electron populations in the Van Allen radiation belt during the September 7–9, 2017 geomagnetic storm. By analyzing the dynamics of the last closed drift shell (LCDS), and the electron flux and phase space density (PSD), we show that the electron dropouts are consistent with magnetopause shadowing and outward radial diffusion to the compressed LCDS. During the recovery phase, an in-bound pass of Van Allen Probe A shows an apparent local peak in PSD, which does not exist in reality. Here, a careful analysis of the multipoint measurements by the Van Allen Probes reveals instead how the apparent PSD peak arises from aliasing monotonic PSD profiles which are rapidly increasing due to acceleration from very fast inwards radial diffusion. In the absence of such multisatellite conjunctions during fast acceleration events, such peaks might otherwise be associated with local acceleration processes.

79 ASTRONOMY AND ASTROPHYSICS↗

Correspondence: Phantom phonon localization in relaxors

Manley et al. report the observation of an unexpected, weak, phonon mode located in energy between that of the transverse acoustic (TA) and soft transverse optic (TO) modes in the relaxor ferroelectric Pb[(Mg 1/3 Nb 2/3 ) 1-x Ti x ]O 3 (PMN-xPT) with Ti content x = 0.30. Referred to as the local mode (LM), the energy of this extra mode varies little with wave vector in the cubic (paraelectric) phase, and this was interpreted as evidence of phonon localization. Any excitation that is localized in space must be extended in reciprocal space Q. To confirm this property, we performed a standard test on a PMN-xPT single crystal of nominally identical composition. This was done by comparing the rates at which the Bragg, TA phonon, and LM neutron scattering cross-sections decrease as the cubic crystallographic [100] axis is tilted out of the horizontal scattering plane by rotating about the orthogonal [010] axis. We find that the LM cross section varies with tilt in a manner identical to that of the Bragg peak. A local mode with short-range spatial correlations that decay exponentially will exhibit a broad Lorentzian peak as a function of tilt. Instead, we observe a narrow Gaussian peak. We conclude that the LM is not a real mode.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Correspondence: Reply to ‘Phantom phonon localization in relaxors’

The Correspondence by Gehring et al. mistakes Anderson phonon localization for the concept of an atomic-scale local mode. An atomic-scale local mode refers to a single atom vibrating on its own within a crystal. Such a local mode will have an almost flat intensity profile, but this is not the same as phonon localization. Anderson localization is a wave interference effect in a disordered system that results in waves becoming spatially localized. The length scale of the localized waves is set by the wavelength, which is approximately 2 nm in this case. This larger length scale in real space means narrower intensity profiles in reciprocal space. Here, we conclude that the claims in the Correspondence by Gehring et al. are incorrect because they mistakenly assume that the length scale for Anderson localization is atomic, and because the experimental observations rule out multiple scattering as the origin.

36 MATERIALS SCIENCE↗

Cosmic ray radiography of a human phantom

Cosmic ray muons that reach the earth's surface provide a natural source of radiation that is used for radiography. In this paper, we show that radiography using the cosmic radiation background provides a method that can be used to monitor bulk aspects of human anatomy. We describe a method that can be used to measure changes in patients as a function of time by cosmic ray muon radiography. Modeling shows muon tomography could provide hourly readouts of parameters such as lung density with sufficient sensitivity to detect the time changes in the inflammation of the lungs in, e.g., COVID patients.

60 APPLIED LIFE SCIENCES↗

Crossing of the phantom divide using tachyon-Gauss-Bonnet gravity

In this paper we consider two models. First, we study tachyon-Gauss-Bonnet gravity and obtain the condition of the equation of state crossing -1. Second, we discuss the modified Gauss-Bonnet gravity with the tachyon field and show the condition of {omega} crossing -1. Also, we plot figures for {omega} numerically in special potential and coupling function.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗