Search NASA⌕ Search

SEARCH · Search NASA

Results for “quantum interference”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Identifying Muons for Neutrino Oscillation and Cross Section Experiments

Neutrinos ($\nu$) are interesting for many reasons; they are the only fundamental fermions which are electrically neutral; their mass is orders of magnitude smaller than the lightest charged lepton, the electron; and their solely weak interactions make them an excellent probe of the weak nuclear force. However, one of the most interesting aspects of neutrinos is that, unlike their charged lepton partners, neutrino mass and flavor eigenstates are not the same. All leptons possess 'lepton flavor', a property which is conserved in neutrino interactions. However, because of the difference in the mass and weak eigenstates of neutrinos, a quantum-interference effect is seen in the time evolution of neutrinos. This results in energy and distance dependent oscillations of the neutrino's lepton flavor called 'neutrino oscillations'. The MINOS experiment (Main Injector Neutrino Oscillation Search) was designed to measure the neutrino oscillation parameters, $\Delta m^2_{32}$ and $sin^2(2\theta_{32})$. MINOS is composed of two detectors located on a 'beam' of v[subscript mu]s. The MINOS Near Detector is located at Fermilab, and the Far Detector is located at the Soudan Mine in Minnesota, 734 km after the Near Detector. The MINER$\nu$A experiment (Main Injector Neutrino Experiment for $\nu$ - A) is a neutrino experiment placed directly in front of the MINOS Near Detector. MINER$\nu$s goal is to make precision measurements of neutrino cross sections. This will help with uncertainties in oscillation measurements, such as MINOS' at low energy. Although lepton flavor is conserved in neutrino interactions, the final state lepton can be a charged lepton ('charged current' interactions) or a neutrino ('neutral current' interactions) of a particular flavor. The identification of charged current $\nu_\mu$ interactions through the identification of a muon in the final state is a critical component to both neutrino oscillation and cross section measurements; neutral current events are a background to the oscillation signal bec! ause the properties of the incoming neutrino cannot be determined. Such identification is particularly difficult and important for low-energy neutrino events. In this thesis, we will discuss improvements to the MINOS charged current identification at low energies, studies to estimate the effect of the neutral current background on the measurement of the oscillation parameters, and the aspects of muon identification which are similar for the MINOS and MINER$\nu$A experiments. In 2010, the MINOS experiment released a measurement of the oscillation parameters based on $7.32x10^{20}$ POT. The results were $\Delta m^2_{32} = 2.32^{+.012}_{-0.08} x 10^3 eV^2$, and $sin^2(2\theta_{32}) > 0.90(90%,C.L.)$. This is the best measurement of the oscillation parameter, $\Delta m^2_{32}$, and a competitive measurement of $sin^2(2\theta_{32})$. The improvements to the charged current event selection helped MINOS observe a complete oscillation in neutrino energy.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Developing Quantum Levitation of ICF Capsules Coated with MgB 2 Thin Films

Current inertial confinement fusion (ICF) capsule support technologies create implosion perturbations which reduce fusion yield, driving the search for new support paradigms. Quantum levitation of the capsule will eliminate the requirement of a physical support structure, increasing fusion yield. The application of an external magnetic field to a capsule coated with a superconducting film can provide the necessary conditions for levitation. Magnesium diboride (MgB 2 ) is an attractive option for ICF applications as it has a high reported superconducting transition temperature of 39 K and is a low Z compound. This project is part of an ongoing effort which seeks to coat ICF capsules with a thin layer of superconducting MgB 2 . This project studied the synthesis of MgB 2 and diffusion/reaction kinetics of B/Mg/B m ultilayer thin films. These films were sputter deposited on flat glassy carbon substrates. Films were annealed in a tube furnace at temperatures between 400 °C and 650 °C for a total of 29 hours with film characterization done at predetermined intervals. At each interval, superconducting properties of the samples were evaluated with superconducting quantum interference device (SQUID) magnetometry, while Rutherford backscattering (RBS) with 2 MeV 4 He + ions was done to determine the composition and depth profile of the films. Scanning electron microscopy (SEM) and atomic force microscopy (AFM) were used to characterize surface morphology. Superconducting behavior was observed in thin films annealed at and above 450 °C. Formation of superconducting MgB 2 at 450 °C h as not been previously reported below 500 °C. The surface of the samples annealed at 500 °C and below was smooth with a measured roughness of ~3 nm. After 29 hours of annealing time, the 450 °C sample had a transition temperature of 27.3 K. The highest transition temperature measured was 30.9 K and was associated with a sample annealed for 29 hours at 650 °C. Transition temperatures were weakly positively correlated with annealing temperature and showed dependence on initial structural quality and oxygen contamination. Current research is attempting to synthesize superconducting MgB 2 coatings on spherical Si beads with the findings of this study. Future efforts are focused on the construction and testing of a levitation apparatus.

36 MATERIALS SCIENCE↗

SQUID-Detected MRI in the Limit of Zero Static Field

This thesis describes an implementation of the so-called"zero-field MRI" (ZFMRI) pulse sequence, which allows for imaging in an arbitrarily low B 0 field. The ZFMRI sequence created an effective unidirectional gradient field by using a train of pi pulses to average out the concomitant gradient components during encoding. The signals were acquired using a low-transition temperature dc Superconducting QUantum Interference Device (low-Tc dc SQUID) coupled to a first-order axial gradiometer. The experiments were carried out in a liquid helium dewar which was magnetically shielded with a single-layer mu-metal can around the outside and a superconducting Pb can contained within the helium space. We increased the filling factor of the custom-made, double-walled Pyrex insert by placing the liquid alcohol sample, at a temperature of approximately -50 degrees C, at the center of one loop of the superconducting gradiometer, which was immersed in the helium bath.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

SQUID magnetometry from nanometer to centimeter length scales

The development of Superconducting QUantum Interference Device (SQUID)-based magnetometer for two applications, in vivo prepolarized, ultra-low field MRI of humans and dispersive readout of SQUIDs for micro- and nano-scale magnetometery, are the focus of this thesis.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Cationic Ordering and Its Influence on the Magnetic Properties of Co-Rich Cobalt Ferrite Thin Films Prepared by Reactive Solid Phase Epitaxy on Nb-Doped SrTiO 3 (001)

Here, we present the (element-specific) magnetic properties and cation ordering for ultrathin Co-rich cobalt ferrite films. Two Co-rich Co x Fe 3-x O 4 films with different stoichiometry (x=1.1 and x=1.4) have been formed by reactive solid phase epitaxy due to post-deposition annealing from epitaxial CoO/Fe 3 O 4 bilayers deposited before on Nb-doped SrTiO 3 (001). The electronic structure, stoichiometry and homogeneity of the cation distribution of the resulting cobalt ferrite films were verified by angle-resolved hard X-ray photoelectron spectroscopy. From X-ray magnetic circular dichroism measurements, the occupancies of the different sublattices were determined using charge-transfer multiplet calculations. For both ferrite films, a partially inverse spinel structure is found with increased amount of Co 3+ cations in the low-spin state on octahedral sites for the Co 1.4 Fe 1.6 O 4 film. These findings concur with the results obtained by superconducting quantum interference device measurements. Further, the latter measurements revealed the presence of an additional soft magnetic phase probably due to cobalt ferrite islands emerging from the surface, as suggested by atomic force microscope measurements.

36 MATERIALS SCIENCE↗

Structure-Related Electronic and Magnetic Properties in Ultrathin Epitaxial Ni x Fe 3–x O 4 Films on MgO(001)

Off-stoichiometric Ni x Fe 3–x O 4 ultrathin films (x < 2.1) with varying Ni content x and thickness 16 (±2) nm were grown on MgO(001) by reactive molecular beam epitaxy. Synchrotron-based high-resolution X-ray diffraction measurements reveal vertical compressive strain for all films, resulting from a lateral pseudomorphic adaption of the film to the substrate lattice without any strain relaxation. Complete crystallinity with smooth interfaces and surfaces is obtained independent of the Ni content x. For x < 1 an expected successive conversion from Fe 3 O 4 to NiFe 2 O 4 is observed, whereas local transformation into NiO structures is observed for films with Ni content x > 1. However, angle-resolved hard X-ray photoelectron spectroscopy measurements indicate homogeneous cationic distributions without strictly separated phases independent of the Ni content, while X-ray absorption spectroscopy shows that also for x > 1, not all Fe 2+ cations are substituted by Ni 2+ cations. The ferrimagnetic behavior, as observed by superconducting quantum interference device magnetometry, is characterized by decreasing saturation magnetization due to the formation of antiferromagnetic NiO parts.

36 MATERIALS SCIENCE↗

Influence of Resonances on the Noise Performance of SQUID Susceptometers

Scanning Superconducting Quantum Interference Device (SQUID) Susceptometry simultaneously images the local magnetic fields and susceptibilities above a sample with sub-micron spatial resolution. Further development of this technique requires a thorough understanding of the current, voltage, and flux ( I V Φ ) characteristics of scanning SQUID susceptometers. These sensors often have striking anomalies in their current–voltage characteristics, which we believe to be due to electromagnetic resonances. The effect of these resonances on the performance of these SQUIDs is unknown. To explore the origin and impact of the resonances, we develop a model that qualitatively reproduces the experimentally-determined I V Φ characteristics of our scanning SQUID susceptometers. We use this model to calculate the noise characteristics of SQUIDs of different designs. We find that the calculated ultimate flux noise is better in susceptometers with damping resistors that diminish the resonances than in susceptometers without damping resistors. Such calculations will enable the optimization of the signal-to-noise characteristics of scanning SQUID susceptometers.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

SQUIDs vs. Faraday coils for ultlra-low field nuclear magnetic resonance: experimental and simulation comparison

Nuclear magnetic resonance (NMR) methods are widely used in medicine, chemistry and industry. One application area is magnetic resonance imaging or MRI. Recently it has become possible to perform NMR and MRI in ultra-low field (ULF) regime that requires measurement field strengths only of the order of 1 Gauss. These techniques exploit the advantages offered by superconducting quantum interference devices or SQUIDs. Our group at LANL has built SQUID based MRI systems for brain imaging and for liquid explosives detection at airports security checkpoints. The requirement for liquid helium cooling limits potential applications of ULF MRI for liquid identification and security purposes. Our experimental comparative investigation shows that room temperature inductive magnetometers provide enough sensitivity in the 3-10 kHz range and can be used for fast liquid explosives detection based on ULF NMR/MRI technique. We describe an experimental and computer simulation comparison of the world's first multichannel SQUID based and Faraday coils based instruments that are capable of performing ULF MRI for liquids identification.

42 ENGINEERING↗

Co-Registration of MEG and ULF MRI using a 7 channel low-Tc SQUID system

In human brain imaging, e.g. pre-surgical mapping, it is highly desired to obtain images with high spatial and temporal resolution. However, no single imaging device is capable of producing both a high spatial resolution anatomical image and a high temporal resolution functional image. During the last couple of years significant efforts have been directed towards magnetic resonance imaging (MRI) in fields comparable to the Earth's field, i.e. microtesla fields, or lower fields. The fields in this range are called ultra-low fields (ULF). Interestingly, the idea of magnetic resonance at microtesla fields is more than 50 years old. In ULF MR it is essential to use pre-polarization to increase the signal-to-noise ratio of the signal from the precessing spins, since the magnetization from the measurement field alone is very small. Even with the present level of prepolarization the ULF images are not as highly resolved as their high-field counterparts. By using a 7 channel system equipped with low transition temperature (T{sub c}) Superconducting QUantum Interference Devices (SQUIDs) to perform both ULF MRI and magnetoencephalography (MEG), it is possible to coregister a lower resolution ULF MR image and an MEG image obtained during one run. Thereby, the MEG data is aligned to the ULF MR image after performing a calibration run with a phantom. The ULF MR image can then be used to align the MEG data onto a high-field MR image. Recently, our group presented the first brain images obtained by ULF MRI. The MR imaging was combined with an MEG session performed a posteriori. The subject's head was moved in between the MRI run and the MEG run and no reference coils were used to quantify the translation. The main reason for the translation of the head was to improve the coverage of the auditory evoked response. In this paper, we report interleaved ULF MRI and MEG measurements co-registered in the same system.

42 ENGINEERING↗

Single Molecule Junctions: Probing Contact Chemistry and Fundamental Circuit Laws

By exploiting selective link chemistry, formation of single molecule junctions with reproducible conductance has become established. Systematic studies reveal the structure-conductance relationships for diverse molecules. I will draw on experiments from my collaborators at Columbia University, atomic-scale calculations and theory to describe progress in two areas. First, I will describe a novel route to form single molecule junctions, based on SnMe3 terminated molecules, in which gold directly bonds to carbon in the molecule backbone resulting in near ideal contact resistance [1]. Second, comparison of the conductance of junctions formed with molecular species containing either one backbone or two backbones in parallel allows demonstration of the role of quantum interference in the conductance superposition law at the molecular scale [2].

36 MATERIALS SCIENCE↗

Modeling and simulation of electron transport at the nanoscale: illustrations in low-dimensional carbon nanostructures

This chapter showcases a few selected illustrations of various manifestations of nanoscale and molecular electronic effects as investigated by quantum mechanical methods. The examples include results demonstrating (1) how graphitic nanoribbons can be assembled into multi-terminal networks and the influence on electron transport; (2) how the position of a single embedded molecule can be modified to change the overall conduction state of a nanowire; (3) how quantum chemical modeling can lead to the design of electrodes with enhanced interface for molecular coupling; (4) how carbon nanotubes can be assembled into complex covalent arrays and how these can be obtained experimentally; (5) how quantum interference can be understood as emerging from the presence of multiple level of confinements in carbon nanorings; and (6) how new functionality can emerge at the nanoscale due the the interplay of magnetic, electronic, and structural properties of individual graphitic nanoribbons assembled into wiggly-like structures.

Meunier, V.↗

Portable MRI developed at Los Alamos

Scientists at Los Alamos National Laboratory are developing an ultra-low-field Magnetic Resonance Imaging (MRI) system that could be low-power and lightweight enough for forward deployment on the battlefield and to field hospitals in the World's poorest regions. "MRI technology is a powerful medical diagnostic tool," said Michelle Espy, the Battlefield MRI (bMRI) project leader, "ideally suited for imaging soft-tissue injury, particularly to the brain." But hospital-based MRI devices are big and expensive, and require considerable infrastructure, such as large quantities of cryogens like liquid nitrogen and helium, and they typically use a large amount of energy. "Standard MRI machines just can't go everywhere," said Espy. "Soldiers wounded in battle usually have to be flown to a large hospital and people in emerging nations just don't have access to MRI at all. We've been in contact with doctors who routinely work in the Third World and report that MRI would be extremely valuable in treating pediatric encephalopathy, and other serious diseases in children." So the Los Alamos team started thinking about a way to make an MRI device that could be relatively easy to transport, set up, and use in an unconventional setting. Conventional MRI machines use very large magnetic fields that align the protons in water molecules to then create magnetic resonance signals, which are detected by the machine and turned into images. The large magnetic fields create exceptionally detailed images, but they are difficult and expensive to make. Espy and her team wanted to see if images of sufficient quality could be made with ultra-low-magnetic fields, similar in strength to the Earth's magnetic field. To achieve images at such low fields they use exquisitely sensitive detectors called Superconducting Quantum Interference Devices, or SQUIDs. SQUIDs are among the most sensitive magnetic field detectors available, so interference with the signal is the primary stumbling block. "SQUIDs are so sensitive they'll respond to a truck driving by outside or a radio signal 50 miles away," said Al Urbaitis, a bMRI engineer. The team's first generation bMRI had to be built in a large metal housing in order to shield it from interference. Now the Los Alamos team is working in the open environment without the large metal housing using a lightweight series of wire coils that surround the bMRI system to compensate the Earth’s magnetic field. In the future, the field compensation system will also function similar to noise-cancelling headphones to eradicate invading magnetic field signals on-the-fly.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

TUNING THE MAGNETOELECTRIC PROPERTIES WITH STRAIN IN EPITAXIAL CO0.9SN0.1FE2O4 THIN FILMS

We have grown epitaxial Sn substituted cobalt ferrite thin films of various thicknesses on piezoelectric Pb(Mg1/3Nb2/(3))(0.72)Ti0.28O3 substrates and investigated the strain-induced changes of magnetic properties. All films described in this work have been deposited by pulsed laser deposition (PLD) from stoichiometric target of Co0.9Sn0.1Fe2O4. The lattice structure, crystallinity and orientation of the thin films were determined by X-ray diffraction analysis. The magnetization of thin films was measured for both, in-plane and out-of-plane configurations, using a superconductor quantum interference device (SQUID) magnetometer at 300 K. The measurements reveal that the magnetic anisotropy is altered by the strain imposed from the substrate upon application of an electric field. The magnetoelastic coupling is demonstrated by a change of the remanent magnetisation. However, we find that this strain effect is thickness dependent. The biggest strain effect is recorded for the thickest film (400nm) where an electric-field-controlled contraction of the substrate of 0.1% induces a relative change in magnetic moment of 9.3%. The relative change of the remanent magnetisation is reduced with decreasing film thickness and is smaller than 3% for the thinnest film (25nm).

epitaxy↗

QUPITER -- Space Quantum Sensors for Jovian-Bound Dark Matter

We propose utilizing space quantum sensors to detect ultralight dark matter (ULDM) bound to planetary bodies, focusing on Jupiter as the heaviest planet in the solar system. Leveraging Jupiter's deep gravitational potential and the wealth of experience from numerous successful missions, we present strong sensitivity projections on the mass and couplings of scalar ULDM. Future space missions offer unique opportunities to probe the ULDM interactions using quantum sensors, including superconducting quantum interference device (SQUID) magnetometers. By measuring dark matter-induced magnetic field oscillations, we expect to achieve sensitivity orders of magnitude beyond the terrestrial probes and significantly improve detection prospects of theoretically motivated ULDM candidates.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Scanning magnetic imaging of Sr2RuO4

We magnetically imaged the ab-plane surface of single crystals of the unconventional superconductor Sr{sub 2}RuO{sub 4}, including one sample with an array of microholes, using scanning superconducting quantum interference device and Hall probe microscopy in a dilution refrigerator at low applied magnetic fields. The images show dilute trapped vortices, as would be expected in conventional type-II superconductors, and no other magnetic features. We found no direct signs of the spontaneous magnetization that would be expected in a time-reversal symmetry-breaking (TRSB) superconductor. These measurements set upper limits on the presence of TRSB signatures in this material.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Phase control of light propagation via Fano interference in asymmetric double quantum wells

We investigate the light propagation and dynamical control of a weak pulsed probe field in asymmetric double quantum wells via Fano interference, which is caused by tunneling from the excited subbands to the same continuum. Our results show that the system can produce anomalous and normal dispersion regions with negligible absorption by choosing appropriate coupling strength of the tunneling and the Fano interference. Interesting enough, the dispersion can be switched between normal and anomalous by adjusting the relative phase between the pulsed probe and coherent control fields owing to the existence of the perfectly Fano interference. Thus, the relative phase can be regarded as a switch to manipulate light propagation with subluminal or superluminal. The temporal and spatial dynamics of the pulsed probe field with hyperbolic secant envelope are analyzed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Discovery of an unconventional quantum echo by interference of Higgs coherence

Detecting photon echoes from superconducting Higgs modes is challenging due to the necessity of preserving and retrieving phase coherence encoded in multiple Higgs and quasiparticle (QP) excitations. Here, we demonstrate the emergence of a Higgs echo in niobium superconductors. This approach disentangles unique quantum pathways involving the Higgs mode and QP excitations. Using Higgs echo spectroscopy, we also uncover unconventional echo formation caused by inhomogeneous broadening and “soft” QP bands, which dynamically evolve under terahertz (THz) driving. Specifically, THz pulse pairs modulate the superconducting gap, imprinting coherence and forming a temporal “Higgs grating.” This grating produces echoes with distinctive characteristics: (i) echo rephasing spectral peaks at superconducting gap frequencies, (ii) asymmetric echo formation delays unlike those observed in atoms or semiconductors, and (iii) negative-time echo signals stemming from Higgs-QP anharmonic interactions. Combined with advanced time-frequency analysis, these findings distinguish Higgs from QP responses and clarify their intricate interactions in THz-driven superconductivity.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗