Search NASA⌕ Search

SEARCH · Search NASA

Results for “sampling methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Predicted aboveground biomass of Typha angustifolia in an upland brackish tidal marsh, PIE LTER, Byfield, MA (2022-2024)

This dataset contains predicted monthly aboveground Typha angustifolia biomass per sample and per square meter in a brackish tidal marsh site dominated by Typha angustifolia near the Parker River in the upper estuary of the Plum Island Sound, Massachusetts (MA) during the growing seasons (May-September) of 2022, 2023, and 2024. This site is also located within the Plum Island Ecosystems Long Term Ecological Research Station (PIE LTER). Allometric equations were developed from dry weight data and associated maximum heights collected in 2022 and 2023. The goal of this study was to investigate the difference in aboveground biomass between the site’s marsh interior (MI) and the creek bank (CB). Metadata files (Typha_biomass_predictions_dd.csv and Typha_biomass_predictions_flmd.csv) contain detailed information on variable definitions, calculations, sampling methods, and the location of the site.

DATE↗

Typha angustifolia non-destructive biomass data from an upland tidal brackish marsh, PIE LTER, Byfield, MA, (2022-2024)

This dataset contains non-destructive measurements of key features of Typha angustifolia samples. These samples were measured during the growing season in 2022, 2023, and 2024 in an upland brackish tidal wetland along the Parker River, Byfield, Massachusetts (MA), which is within the Plum Island Ecosystems Long Term Ecological Research Station (PIE LTER). Measurements were taken to investigate the difference in above ground biomass between two locations, the marsh interior (MI) and the creek bank (CB) and to support an allometric equation used to predict aboveground Typha angustifolia biomass per square meter. No QA/QC procedures were applied to the data. Metadata files Typha_biomass_observations_dd.csv and Typha_biomass_observations_flmd.csv contain detailed information on variable definitions, sampling methods, and the location of the site.

CULM_D_1↗

Topsoil bulk geochemical compositions - An updated harmonized global dataset

Mineral weathering is a key biogeochemical process because of the capacity of minerals to stabilize organic matter. However, predicting soil weathering status across large spatial areas still isn’t possible due to a lack of global data and theoretical frameworks. To address this knowledge gap, multiple global datasets of bulk topsoil geochemical compositions have been harmonized using R. These datasets document topsoil bulk geochemical compositions across five continents (n = ~16,000 observations). Source data for these observations include the EuroGEOSurveys Geochemical Baseline Database (FOREGS), the US Geological Survey National Geochemical Database (NASGLP), the Geochemical Atlas of Australia (GAA), the US Geological Survey Alaska Geochemical Database (AGD84), the National Cooperative Soil Survey (NCSS), the European Geochemical Mapping of Agricultural Soil (GEMAS), Ecorespira-Amazon (ERA), the New Zealand Geochemical Baseline Survey (NZ_GBS), and the African Soil Information Service (AFSIS). Major elements observed include Aluminum (Al), Calcium (Ca), Iron (Fe), Potassium (K), Magnesium (Mg), Sodium (Na), Titanium (Ti), Manganese (Mn), Phosphorus (P), Carbon (C), and Sulfur (S). This data package includes the harmonized dataset itself, and the R scripts necessary to harmonize these datasets, in addition to metadata that describes all columns, files, and databases used in this project. Methods & Sampling Step 1 – Databases of geochemical data identified This study aimed to leverage existing measurements of topsoil geochemical data. Databases were first identified and deemed appropriate for inclusion if they were measuring soils and performed these measurements on the <2mm soil fraction. Databases such as NCSS and AGD84 needed more post processing to include in the database and this was done using the NCSS_datamerge_031626 R file and Alaska_USGSmerge_031626 R file, respectively. Step 2 – Database harmonization Once appropriate databases were identified, they were harmonized for ease of analysis using the R script Database_Harmonization_031826. This included removing columns from original datasets that would not be used in analysis (removed columns are noted in the code). Then, data cleaning procedures specific to each dataset were undertaken. This includes standardizing columns to include units and adding metadata columns regarding procedures for analyzing specific elements. Functions for standardizing measurements and units are outline in R files: calculate element_mg_kg_031626, calculate_oxide_wt_perc_031626, change_oxide_caps_031626, and conv_2_numeric_031626. This also included adding a unique identifier for each sample to identify it with its respective database (see CD_ID in data dictionary). Geographic information: Data reflect a compilation of datasets collected globally. Geographic areas covered by each of the datasets include: - EuroGEOSurveys Geochemical Baseline Database (FOREGS) - European continent - North American Soil Geochemical Landscapes (NASGLP) - continental United States and limited parts of Canada (see database key for more details) - National Geochemical Survey of Australia (GAA) - Australia - Alaska geochemical database (AGDB4) - Alaska - National Cooperative Soil Survey (NCSS) - Global measurements, but concentrated in the continental United States - Geochemical data for arable land and land under permanent grass cover in continental Europe (GEMAS) - continental Europe - Ecorespira-Amazon (ERA) - Geochemical data from the Amazon basin - Geochemical baseline data for New Zealand (NZGBS) - New Zealand - Geochemical data collected across continental Africa (AfSIS) - Measurements across Africa

EARTH SCIENCE > LAND SURFACE > SOILS↗

REACTION SAMPLING IN MCATK: Using the Thermal Motion of the Target Nucleus to Perform Elastic and Inelastic Scattering (U)

We describe how the reaction sampling is currently performed in MCATK. The current reaction sampling method is modeled on the method coded in MCNP6 and briefly described in the MCNP manual. The method is validated using the MCATK criticality validation suite for comparison with MCNP6. The results of this validation suite show good agreement with results obtained with MCNP6.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

2012 Groundwater Monitoring Report Central Nevada Test Area, Subsurface Corrective Action Unit 443

The Central Nevada Test Area was the site of a 0.2- to 1-megaton underground nuclear test in 1968. The surface of the site has been closed, but the subsurface is still in the corrective action process. The corrective action alternative selected for the site was monitoring with institutional controls. Annual sampling and hydraulic head monitoring are conducted as part of the subsurface corrective action strategy. The site is currently in the fourth year of the 5-year proof-of-concept period that is intended to validate the compliance boundary. Analytical results from the 2012 monitoring are consistent with those of previous years. Tritium remains at levels below the laboratory minimum detectable concentration in all wells in the monitoring network. Samples collected from reentry well UC-1-P-2SR, which is not in the monitoring network but was sampled as part of supplemental activities conducted during the 2012 monitoring, indicate concentrations of tritium that are consistent with previous sampling results. This well was drilled into the chimney shortly after the detonation, and water levels continue to rise, demonstrating the very low permeability of the volcanic rocks. Water level data from new wells MV-4 and MV-5 and recompleted well HTH-1RC indicate that hydraulic heads are still recovering from installation and testing. Data from wells MV-4 and MV-5 also indicate that head levels have not yet recovered from the 2011 sampling event during which several thousand gallons of water were purged. It has been recommended that a low-flow sampling method be adopted for these wells to allow head levels to recover to steady-state conditions. Despite the lack of steady-state groundwater conditions, hydraulic head data collected from alluvial wells installed in 2009 continue to support the conceptual model that the southeast-bounding graben fault acts as a barrier to groundwater flow at the site.

54 ENVIRONMENTAL SCIENCES↗

CASL Institutional Computing Report, CY2013 [Slides]

• FY14: Mini-PIRTs conducted on challenge problems to provide subject matter input on important physics models, experimental data, and figures of merit – Progression problem 6, CIPS, PCI – RIA and LOCA up next • Tailor “generic” VUQ plan (FY14 milestone) to each challenge problem – Appendix to challenge problem charters • FY15: Full implementation of probabilistic model calibration capability – Complete implementation of GPMSA in QUESO – Complete verification tests of sampling algorithms in QUESO – Complete Dakota-QUESO interface • FY15: Demonstrate dimension reduction capability for large input spaces – Hybrid sampling methods for ESM dimension reduction and probabilistic calibration.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Verifying and Validating Simulation Models

This presentation is a high-level discussion of the Verification and Validation (V&V) of computational models. Definitions of V&V are given to emphasize that “validation” is never performed in a vacuum; it accounts, instead, for the current state-of-knowledge in the discipline considered. In particular comparisons between physical measurements and numerical predictions should account for their respective sources of uncertainty. The differences between error (bias), aleatoric uncertainty (randomness) and epistemic uncertainty (ignorance, lack-of- knowledge) are briefly discussed. Four types of uncertainty in physics and engineering are discussed: 1) experimental variability, 2) variability and randomness, 3) numerical uncertainty and 4) model-form uncertainty. Statistical sampling methods are available to propagate, and analyze, variability and randomness. Numerical uncertainty originates from the truncation error introduced by the discretization of partial differential equations in time and space. Model-form uncertainty is introduced by assumptions often formulated to render a complex problem more tractable and amenable to modeling and simulation. The discussion concludes with high-level guidance to assess the “credibility” of numerical simulations, which stems from the level of rigor with which these various sources of uncertainty are assessed and quantified.

Mathematics & Computing(97)↗

An Uncertainty Analysis of the Hydrogen Source Term for a Station Blackout Accident in Sequoyah Using MELCOR 1.8.5

A methodology for using the MELCOR code with the Latin Hypercube Sampling method was developed to estimate uncertainty in various predicted quantities such as hydrogen generation or release of fission products under severe accident conditions. In this case, the emphasis was on estimating the range of hydrogen sources in station blackout conditions in the Sequoyah Ice Condenser plant, taking into account uncertainties in the modeled physics known to affect hydrogen generation. The method uses user-specified likelihood distributions for uncertain model parameters, which may include uncertainties of a stochastic nature, to produce a collection of code calculations, or realizations, characterizing the range of possible outcomes. Forty MELCOR code realizations of Sequoyah were conducted that included 10 uncertain parameters, producing a range of in-vessel hydrogen quantities. The range of total hydrogen produced was approximately 583kg ± 131kg. Sensitivity analyses revealed expected trends with respected to the parameters of greatest importance, however, considerable scatter in results when plotted against any of the uncertain parameters was observed, with no parameter manifesting dominant effects on hydrogen generation. It is concluded that, with respect to the physics parameters investigated, in order to further reduce predicted hydrogen uncertainty, it would be necessary to reduce all physics parameter uncertainties similarly, bearing in mind that some parameters are inherently uncertain within a range. It is suspected that some residual uncertainty associated with modeling complex, coupled and synergistic phenomena, is an inherent aspect of complex systems and cannot be reduced to point value estimates. The probabilistic analyses such as the one demonstrated in this work are important to properly characterize response of complex systems such as severe accident progression in nuclear power plants.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Importance Sampling Variance Reduction in GRESS ATMOSIM

This document is intended to introduce the importance sampling method of variance reduction to a Geant4 user for application to neutral particle Monte Carlo transport through the atmosphere, as implemented in GRESS ATMOSIM.

47 OTHER INSTRUMENTATION↗

Reducing Computation and Communication in Scientific Computing: Connecting Theory to Practice.

This report summarizes the work produced as part of a Truman Fellowship appointment and its associated LDRD project. The overall goal of the project was to develop better algorithms and implementations for key computational kernels within the field of scientific computing by designing them to be communication efficient, moving as little data as possible. The primary problem of interest was dense matrix multiplication; other computations that were addressed include sparse matrix-matrix multiplication, QR factorization, solving symmetric linear systems, and the symmetric eigendecomposition. The project also involved the study of computations at the intersection of scientific computing and data analysis, including nonnegative matrix factorization for discovering latent factors, Tucker tensor decomposition for data compression, and sampling methods for similarity search.

97 MATHEMATICS AND COMPUTING↗

Results of the 2018 Wood Stove Design Challenge

The 2018 Wood Stove Design Challenge was an international design competition which sought to identify top performing residential wood stoves based on automation. To prepare for the event, the Northeast States for Coordinated Air Use Management (NESCAUM) developed a testing protocol that challenged the stoves by testing them in more field-like conditions—capturing emissions from start-up, reloading a stove, and the use of larger piece sizes. Flue gas emissions were measured using a combination of in-stack and novel dilution sampling methods, as the event occurred on the National Mall in Washington D.C. in a non-laboratory setting. Particulate matter (PM), carbon monoxide (CO), carbon dioxide (CO2), and methane (CH4) were measured from three stoves in real-time. A combustion efficiency was also calculated for each stove in real-time. Measured PM emission rates ranged between 1.8 and 8.0 g/hr for all stoves and operating conditions, with the highest emissions being measured during cold start in all cases. The test average PM emission rates were 2.4, 4.0, and 2.4 g/hr for stoves A, B, and C, respectively. Results showed emissions measured during transient operations, which are often excluded in current certification methods, can be significantly higher than steady-state periods—echoing other studies and highlighting the importance of testing in various operational modes for more realistic emission estimates. Additionally, the stoves had overall CO emission rates of 48.8, 284.8, and 100.8 g/hr, for stoves A, B and C, respectively. Calculated PM and CO emission factors overall were low considering the testing protocol sought to follow more challenging yet realistic practices in terms of fuel loading and operating procedures. The overall estimated combustion efficiency for stoves A, B, and C was 85%, 78%, 76%, respectively and in all cases was lowest during the cold start period.This report details the successfully proposed and assembled instrumentation that was relatively portable for field-site testing and the results of the emissions measurements for the 2018 Wood Stove Design Challenge competition. Overall, the repeatability of each stove was favorable with coefficients of variation (COV) ranging from 7 to 15% for measured PM concentrations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ComStock Reference Documentation (V.1)

The commercial building sector stock model, or ComStock™, is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual sub-hourly energy consumption of the commercial building stock across the United States. ComStock asks and answers two questions: how is energy used in the U.S. building stock and what are the impact of energy saving technologies. Specifically, ComStock identifies where energy is being consumed geographically, in what building types and end uses, and at what times of day. Simultaneously, it identifies the impact of efficiency measures: how much energy do efficiency measures save; where, or in what use cases do measures save energy; when, or at what time of day do savings occur; and which building stock segments have the biggest savings potential. This document contains the methodology and assumptions behind ComStock and serves as a guide to its use.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

2011 Groundwater Monitoring Report, Central Nevada Test Are, Subsurface Corrective Action Unit 443

The Central Nevada Test Area was the site of a 0.2- to 1-megaton underground nuclear test in 1968. The surface of the site has been closed, but the subsurface is still in the corrective action process. The corrective action alternative selected for the site was proof-of-concept and monitoring with institutional controls. Annual sampling and hydraulic head monitoring are conducted as part of the subsurface corrective action strategy. The site is currently in the third year of the 5-year proof-of-concept period that is intended to validate the compliance boundary. Analytical results from the 2011 monitoring are consistent with those of previous years. Tritium remains at levels below detection in all wells. Water levels continue to rise in the reentry well UC-1-P-2SR that was drilled into the chimney shortly after the detonation, demonstrating the very low permeability of the volcanic rocks. Water level data from the new wells MV-4 and MV-5 and recompleted well HTH-1RC indicate that hydraulic heads are still recovering from installation and testing. Data from wells MV-4 and MV-5 also indicate that head levels do not recover after yearly sampling events during which several thousand gallons of water are purged. It is recommended that low-flow sampling methods be adopted for these wells to allow head levels to recover to steady-state conditions. Despite the lack of steady-state groundwater conditions, hydraulic head data collected from alluvial wells installed in 2009 continue to support the conceptual model that the southeast-bounding graben fault acts as a barrier to flow at the site.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

2013 Groundwater Monitoring Report, Central Nevada Test Area Subsurface Corrective Action Unit 443

The Central Nevada Test Area was the site of a 0.2- to 1-megaton underground nuclear test in 1968. The surface of the site has been closed, but the subsurface is still in the corrective action process. The corrective action alternative selected for the site was monitoring with institutional controls. Annual sampling and hydraulic head monitoring of the well network are conducted as part of the subsurface corrective action strategy for the site. The monitoring well network was enhanced in 2013 with the installation of a new well MV-6. The site is currently in the fifth year of the 5-year proof-of-concept monitoring period. Analytical results from the 2013 monitoring are consistent with those of previous years indicating no tritium or 14 C concentrations above the required detection limits. Water level data from new wells MV-4 and MV-5 and recompleted well HTH-1RC indicate that hydraulic heads are still recovering from installation and testing. Data from wells MV-4 and MV-5 also indicate that head levels have not yet recovered from the 2011 sampling event during which several thousand gallons of water were purged. Low-flow bladder pumps were installed during the November 2013 sampling event to reduce the well purge volumes and the impact purging has on the water levels during sampling. The new bladder pumps allow the collection of groundwater samples using the low-flow sampling method and will allow head levels to recover to steadystate conditions. Despite the lack of steady-state groundwater conditions, hydraulic head data collected from site continue to support the conceptual model that the southeast-bounding graben fault acts as a barrier to groundwater flow at the site.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

End-Use Savings Shapes Measure Documentation: Variable Refrigerant Flow with Heat Recovery and Dedicated Outdoor Air System

Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy's ResStock™ and ComStock™ models over the past 3 years, the objective of this work is to produce national data sets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) measures. "Measures" refers to energy efficiency variables that can be applied to buildings during modeling. An end-use savings shape is the difference in energy consumption between a baseline building and a building with an energy efficiency, electrification, or demand flexibility measure applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology and results of the baseline model are discussed in the final technical report of the End-Use Load Profiles project. This documentation focuses on a single heating, ventilation, and air-conditioning (HVAC) end-use savings shape measure - a variable refrigerant flow with heat recovery (VRF HR) heating and cooling system coupled with a dedicated outdoor air system (DOAS) for ventilation. This measure replaces existing multi-zone variable air volume (VAV) systems or single-zone rooftop units (RTU) with a VRF HR system coupled with a DOAS that includes an energy/heat recovery ventilator (E/HRV). The measure covers 53% of exisiting building stock's floor area and is not applicable to HVAC system types using district heating or cooling or buildings/spaces that include high-ventilation spaces such as kitchens where the amount of exhaust air is large. A DOAS with E/HRV is used to provide required outdoor ventilation air to spaces since ventilation air is generally not supplied by a VRF HR system. An exhaust air energy recovery ventilator (ERV ) with sensible and latent heat exchange is added to humid climate zones while a heat recovery ventilator (HRV ) with sensible only exchange is added to drier climate zones. The ERV is modeled as a fixed membrane plate counterflow heat exchanger, while the HRV is modeled as a sensible-only fixed aluminum plate counterflow heat exchanger. Both systems include a bypass (for temperature control and economizer lockout) and minimum exhaust temperature control for frost prevention.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

End-Use Savings Shapes Measure Documentation: LED Lighting

Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy's ResStock and ComStock models over the past three years, the objective of this work is to produce national data sets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) measures. "Measures" refers to energy efficiency variables that can be applied to buildings during modeling. An end-use savings shape is the difference in energy consumption between a baseline building and a building with an energy efficiency, electrification, or demand flexibility measure applied. It results in a timeseries profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each timestep. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology and results of the baseline model are discussed in the final technical report of the End-Use Load Profiles project. This documentation focuses on a single end-use savings shape measure - LED lighting. The LED lighting measure replaces interior lights with LEDs where applicable. The measure resulted in 1.25 TBtu energy savings across the building stock, with the majority of savings occurring in retail and warehouse buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

End-Use Savings Shapes Measure Documentation: Economizers

Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy's ResStock™ and ComStock™ models over the past 3 years, the objective of this work is to produce national data sets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) measures. "Measures" refers to energy efficiency variables that can be applied to buildings during modeling. An end-use savings shape is the difference in energy consumption between a baseline building and a building with an energy efficiency, electrification, or demand flexibility measure applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each time step. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual subhourly energy consumption of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology and results of the baseline model are discussed in the final technical report of the End-Use Load Profiles project.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

End-Use Savings Shapes Measure Documentation: Boiler Replacement with Air-Source Heat Pump Boiler and Electric Boiler Backup

Building on the successfully completed effort to calibrate and validate the U.S. Department of Energy's ResStock TM and ComStock TM models over the past three years, the objective of this work is to produce national data sets that empower analysts working for federal, state, utility, city, and manufacturer stakeholders to answer a broad range of analysis questions. The goal of this work is to develop energy efficiency, electrification, and demand flexibility end-use load shapes (electricity, gas, propane, or fuel oil) that cover a majority of the high-impact, market-ready (or nearly market-ready) measures. "Measures" refers to energy efficiency variables that can be applied to buildings during modeling. An end-use savings shape is the difference in energy consumption between a baseline building and a building with an energy efficiency, electrification, or demand flexibility measure applied. It results in a time-series profile that is broken down by end use and fuel (electricity or on-site gas, propane, or fuel oil use) at each timestep. ComStock is a highly granular, bottom-up model that uses multiple data sources, statistical sampling methods, and advanced building energy simulations to estimate the annual sub hourly energy consumption of the commercial building stock across the United States. The baseline model intends to represent the U.S. commercial building stock as it existed in 2018. The methodology and results of the baseline model are discussed in the final technical report of the End-Use Load Profiles project. This documentation focuses on a single end-use savings shape measure—boiler replacement by air-source heat pump boiler. This measure replaces space heating natural gas boilers by air-source heat pump boilers when applicable and helps quantify the decarbonization as well as the energy savings potential from the replacement. The measure resulted higher savings in natural gas consumption compared to the increase in electricity consumption, with a ratio of 2.9. The total natural gas energy consumption was reduced by 20%, whereas the total electricity consumption was increased by 2.5%.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗