Search NASA⌕ Search

SEARCH · Search NASA

Results for “scoring system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Electron contamination modeling and skin dose in 6 MV longitudinal field MRIgRT: Impact of the MRI and MRI fringe field

Purpose: In recent times, longitudinal field MRI-linac systems have been proposed for 6 MV MRI-guided radiotherapy (MRIgRT). The magnetic field is parallel with the beam axis and so will alter the transport properties of any electron contamination particles. The purpose of this work is to provide a first investigation into the potential effects of the MR and fringe magnetic fields on the electron contamination as it is transported toward a phantom, in turn, providing an estimate of the expected patient skin dose changes in such a modality. Methods: Geant4 Monte Carlo simulations of a water phantom exposed to a 6 MV x-ray beam were performed. Longitudinal magnetic fields of strengths between 0 and 3 T were applied to a 30 x 30 x 20 cm{sup 3} phantom. Surrounding the phantom there is a region where the magnetic field is at full MRI strength, consistent with clinical MRI systems. Beyond this the fringe magnetic field entering the collimation system is also modeled. The MRI-coil thickness, fringe field properties, and isocentric distance are varied and investigated. Beam field sizes of 5 x 5, 10 x 10, 15 x 15 and 20 x 20 cm{sup 2} were simulated. Central axis dose, 2D virtual entry skin dose films, and 70 {mu}m skin depth doses were calculated using high resolution scoring voxels. Results: In the presence of a longitudinal magnetic field, electron contamination from the linear accelerator is encouraged to travel almost directly toward the patient surface with minimal lateral spread. This results in a concentration of electron contamination within the x-ray beam outline. This concentration is particularly encouraged if the fringe field encompasses the collimation system. Skin dose increases of up to 1000% were observed for certain configurations and increases above Dmax were common. In nonmagnetically shielded cases, electron contamination generated from the jaw faces and air column is trapped and propagated almost directly to the phantom entry region, giving rise to intense dose hot spots inside the x-ray treatment field. These range up to 1000% or more of Dmax at the CAX, depending on field size, isocenter, and coil thickness. In the case of a fully magnetically shielded collimation system and the lowest MRI field of 0.25 T, the entry skin dose is expected to increase to at least 40%, 50%, 65%, and 80% of Dmax for 5 x 5, 10 x 10, 15 x 15, and 20 x 20 cm{sup 2}, respectively. Conclusions: Electron contamination from the linac head and air column may cause considerable skin dose increases or hot spots at the beam central axis on the entry side of a phantom or patient in longitudinal field 6 MV MRIgRT. This depends heavily on the properties of the magnetic fringe field entering the linac beam collimation system. The skin dose increase is also related to the MRI-coil thickness, the fringe field, and the isocenter distance of the linac. The results of this work indicate that the properties of the MRI fringe field, electron contamination production, and transport must be considered carefully during the design stage of a longitudinal MRI-linac system.

43 PARTICLE ACCELERATORS↗

Implementation of IMRT and VMAT using Delta4 phantom and portal dosimetry as dosimetry verification tools

In this study we analyzed and compared the dose distribution of different IMRT and VMAT plans with the intent to provide pre-treatment quality assurance using two different tools. Materials/Methods: We have used the electronic portal imaging device EPID after calibration to dose and correction for the background offset signal and also the Delta4 phantom after en evaluation of angular sensitivity. The Delta4 phantom has a two-dimensional array with ionization chambers. We analyzed three plans for each anatomical site calculated by Eclipse treatment planning system. The measurements were analyzed using γ-evaluation method with passing criteria 3% absolute dose and 3 mm distance to agreement (DTA). For all the plans the range of score has been from 97% to 99% for gantry fixed at 0° while for rotational planes there was a slightly decreased pass rates and above 95%. Point measurement with a ionization chamber were done in additional to see the accuracy of portal dosimetry and to evaluate the Delta4 device to various dose rates. Conclusions: Both Delt4 and Portal dosimetry shows good results between the measured and calculated doses. While Delta4 is more accurate in measurements EPID is more time efficient. We have decided to use both methods in the first steps of IMRT and VMAT implementation and later on to decide which of the tools to use depending on the complexity of plans, how much accurate we want to be and the time we have on the machine.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Anomaly detection in Hyper Suprime-Cam galaxy images with generative adversarial networks

ABSTRACT The problem of anomaly detection in astronomical surveys is becoming increasingly important as data sets grow in size. We present the results of an unsupervised anomaly detection method using a Wasserstein generative adversarial network (WGAN) on nearly one million optical galaxy images in the Hyper Suprime-Cam (HSC) survey. The WGAN learns to generate realistic HSC-like galaxies that follow the distribution of the data set; anomalous images are defined based on a poor reconstruction by the generator and outlying features learned by the discriminator. We find that the discriminator is more attuned to potentially interesting anomalies compared to the generator, and compared to a simpler autoencoder-based anomaly detection approach, so we use the discriminator-selected images to construct a high-anomaly sample of ∼13 000 objects. We propose a new approach to further characterize these anomalous images: we use a convolutional autoencoder to reduce the dimensionality of the residual differences between the real and WGAN-reconstructed images and perform UMAP clustering on these. We report detected anomalies of interest including galaxy mergers, tidal features, and extreme star-forming galaxies. A follow-up spectroscopic analysis of one of these anomalies is detailed in the Appendix; we find that it is an unusual system most likely to be a metal-poor dwarf galaxy with an extremely blue, higher-metallicity H ii region. We have released a catalogue with the WGAN anomaly scores; the code and catalogue are available at https://github.com/kstoreyf/anomalies-GAN-HSC; and our interactive visualization tool for exploring the clustered data is at https://weirdgalaxi.es.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-E-T-325: The New Evaluation Method of the VMAT Plan Delivery Using Varian DynaLog Files and Modulation Complexity Score (MCS)

Purpose: The aim of the study is to evaluate the use of Varian DynaLog files to verify VMAT plans delivery and modulation complexity score (MCS) of VMAT. Methods: Delivery accuracy of machine performance was quantified by multileaf collimator (MLC) position errors, gantry angle errors and fluence delivery accuracy for volumetric modulated arc therapy (VMAT). The relationship between machine performance and plan complexity were also investigated using the modulation complexity score (MCS). Plan and Actual MLC positions, gantry angles and delivered fraction of monitor units were extracted from Varian DynaLog files. These factors were taken from the record and verify system of MLC control file. Planned and delivered beam data were compared to determine leaf position errors and gantry angle errors. Analysis was also performed on planned and actual fluence maps reconstructed from those of the DynaLog files. This analysis was performed for all treatment fractions of 5 prostate VMAT plans. The analysis of DynaLog files have been carried out by in-house programming in Visual C++. Results: The root mean square of leaf position and gantry angle errors were about 0.12 and 0.15, respectively. The Gamma of planned and actual fluence maps at 3%/3 mm criterion was about 99.21. The gamma of the leaf position errors were not directly related to plan complexity as determined by the MCS. Therefore, the gamma of the gantry angle errors were directly related to plan complexity as determined by the MCS. Conclusion: This study shows Varian dynalog files for VMAT plan can be diagnosed delivery errors not possible with phantom based quality assurance. Furthermore, the MCS of VMAT plan can evaluate delivery accuracy for patients receiving of VMAT. Machine performance was found to be directly related to plan complexity but this is not the dominant determinant of delivery accuracy.

60 APPLIED LIFE SCIENCES↗

Parasail: SIMD C library for global, semi-global, and local pairwise sequence alignments

Sequence alignment algorithms are a key component of many bioinformatics applications. Though various fast Smith-Waterman local sequence alignment implementations have been developed for x86 CPUs, most are embedded into larger database search tools. In addition, fast implementations of Needleman-Wunsch global sequence alignment and its semi-global variants are not as widespread. This article presents the first software library for local, global, and semi-global pairwise intra-sequence alignments and improves the performance of previous intra-sequence implementations. As a result, a faster intra-sequence pairwise alignment implementation is described and benchmarked. Using a 375 residue query sequence a speed of 136 billion cell updates per second (GCUPS) was achieved on a dual Intel Xeon E5-2670 12-core processor system, the highest reported for an implementation based on Farrar’s ’striped’ approach. When using only a single thread, parasail was 1.7 times faster than Rognes’s SWIPE. For many score matrices, parasail is faster than BLAST. The software library is designed for 64 bit Linux, OS X, or Windows on processors with SSE2, SSE41, or AVX2. Source code is available from https://github.com/jeffdaily/parasail under the Battelle BSD-style license. In conclusion, applications that require optimal alignment scores could benefit from the improved performance. For the first time, SIMD global, semi-global, and local alignments are available in a stand-alone C library.

97 MATHEMATICS AND COMPUTING↗

A comparison of head and manual control for a position-control pursuit tracking task

Head control was compared with manual control in a pursuit tracking task involving proportional controlled-element dynamics. An integrated control/display system was used to explore tracking effectiveness in horizontal and vertical axes tracked singly and concurrently. Compared with manual tracking, head tracking resulted in a 50 percent greater rms error score, lower pilot gain, greater high-frequency phase lag and greater low-frequency remnant. These differences were statistically significant, but differences between horizontal- and vertical-axis tracking and between 1- and 2-axis tracking were generally small and not highly significant. Manual tracking results were matched with the optimal control model using pilot-related parameters typical of those found in previous manual control studies. Head tracking performance was predicted with good accuracy using the manual tracking model plus a model for head/neck response dynamics obtained from the literature.

Levison, W. H.↗

Target tracking system

Methods and apparatuses for identifying a track for a target are disclosed herein. In a general embodiment, trees for targets are identified. Each tree in the trees includes observations that are connected to each other by branches and each observation has a score. A selected track in a tree is identified within the trees with an observation having a highest score. A group of branches is added to the selected track from other trees other than the tree having the selected track to form the track for a target, enabling reducing processing resources used to identify the track.

99 GENERAL AND MISCELLANEOUS↗

New framework for benchmarking decadal predictions leveraging the PCMDI Metric Package with interactive visualization

Reliable climate predictions across multiple timescales are increasingly critical as climate-related risks continue to rise. With the growing number and diversity of climate prediction systems, systematic intercomparison has become essential. Here, we present a comprehensive evaluation framework based on the PCMDI Metric Package to assess the performance of multiple decadal climate prediction systems. Unlike uninitialized simulations, initialized predictions exhibit bias and predictive skill that evolve with forecast lead time. To address this, we introduce (1) model-by-lead-time portrait plots, which efficiently summarize metrics of global temperature, precipitation, and Arctic/Antarctic sea-ice extent, and (2) an HTML-based interactive visualization platform that provides detailed regional and seasonal diagnostics of model bias, skill scores, and ensemble spread for each model and lead time. Comparisons with uninitialized simulations further quantify the relative impacts of initialization and external forcing on prediction skill. The proposed framework provides a scalable and transparent approach for multi-model climate prediction assessments and can be readily extended to a wide range of operational and research forecasting systems.

54 ENVIRONMENTAL SCIENCES↗

A Geo-Data Science Method for Assessing Unconventional Rare-Earth Element Resources in Sedimentary Systems

Abstract Rare-earth elements (REEs) supply raw materials that constitute many of our modern critical infrastructure, defense, technology, and electrification needs. Despite REE accumulations occurring in conventional bedrock and ion-adsorption deposits sourced from weathering of igneous rocks, unconventional host materials such as coal and related sedimentary strata have been identified as promising sources of REEs to meet growing demand. To maximize the potential of unconventional resources such as REE-coal systems, new approaches are needed overcome challenges from mineral systems with no known deposits and areas with sparse geochemical data. This article presents a systematic knowledge-data resource assessment method for predicting and identifying REE resource potential and occurrence in these unconventional systems. The method utilizes a geologic and geospatial knowledge-data approach informed and guided by REE accumulation mechanisms to systematically assess and identify areas of higher enrichment. An assessment of the Powder River Basin is presented as a test case to demonstrate the method workflow and results. The key output is a potential enrichment score map reported with varying confidence levels based on the amount of supporting evidence. Results from the test case indicate several locations with promising potential for different types of coal-REE deposits, demonstrating the viability of the method for exploration and assessment of unconventional REE resources. The method is flexible by design and, with sufficient applicable knowledge and data, can be adapted for assessing critical mineral systems in other sedimentary systems as well.

58 GEOSCIENCES↗

Measurement and evaluation of sustainable development

This paper develops a methodology to analyse, measure and evaluate sustainable development (SD). A holistic approach (systems analysis) is applied to operationalise the SD concept and an integrated approach (composite indicator construction) is adopted for the measurement of SD. The operationalisation of the SD concept is based on an in-depth systems analysis of issues associated with economic, social and environmental problems in a policy context. The composite indicator (overall sustainability index) is developed based on the three composite sub-indicators of the SD dimensions. The valuation of the SD is based both on the aggregated sub-indicators and the overall composite indicator. The methodology is used to evaluate the SD of the North Aegean islands between different temporal points. The assessment of the change in the islands' SD is based on a quartile grading scale of the overall SD composite scores.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Evaluation of Planetary Extravehicular Activity Prebreathe Protocols using a 56.5 kPa, 34% O2, 66% N2 Saturation Cabin Atmosphere in an 11-day Hypobaric Hypoxia Study

INTRODUCTION: Apollo missions used 100% O2 cabin atmospheres which effectively eliminated the risk of decompression sickness (DCS) during Lunar extravehicular activities (EVAs, ‘spacewalks’); however, this atmosphere presented a flammability risk that is no longer acceptable to NASA. Denitrogenation prebreathe protocols used to mitigate DCS risk for Space Shuttle and International Space Station EVAs are validated for the microgravity environment, but the significantly increased risk of DCS during equivalent ambulatory surface EVAs make these protocols inapplicable to planetary/Lunar missions. A cabin/vehicle “Exploration Atmosphere” of 56.5 kPa (8.2 psia), 34% O2, 66% N2 has been recommended by NASA for future Moon and Mars missions as a compromise that balances subsequent pre-EVA prebreathe duration, hypoxia, and flammability risk, assuming a 29.6 kPa (4.3 psi) spacesuit. Prebreathe validation studies were initiated utilizing a three-story 6m diameter hypobaric chamber at NASA’s Johnson Space Center. Here, we report the results of a 11-day human-in-the-loop system checkout. METHODS: Six volunteers lived in a hyboparic chamber for 11 days with an ‘exploration atmosphere’ of 56.6kPa/34% O2 66% N2. Subjects acclimated to the exploration atmosphere for 48hrs and thereafter participated in five 6-hour simulated EVAs at 34kPa/85% O2 / 15% N2 over the course of 11 days. Prior to each simulated EVA, subjects underwent a 20-minute prebreathe at 85% O2. The EVA simulation was designed to include tasks that are physically and ergonomically representative of future planetary EVAs, proportionate to the subject’s VO2max. Decompression stress was evaluated during the simulated EVA by serial doppler and echocardiographs alternating every 15min, as well as clinical monitoring for DCS signs/symptoms. RESULTS AND DISCUSSION: Venous gas emboli (VGE) were present in 3 of 6 subjects during EVAs, with peak Grade II VGE as evaluated by Doppler and a peak Eftedal-Brubakk score of 5 by cardiac ultrasonography. Two cases of DCS were diagnosed during the 11-day test chamber. No acute hypoxic symptoms were noted. Musculoskeletal and gastrointestinal complaints were noted, likely associated with the exercise load and the food system. Two cases of DCS (8%) does not cross either accept or reject pre-test criterion, so an additional study is planned for 2023 to meet our pre-test thresholds.

Alejandro Garbino↗

Score-P: A Joint Performance Measurement Run-Time Infrastructure for Periscope, Scalasca, TAU, and Vampir.

This paper gives an overview about the Score-P performance measurement infrastructure which is being jointly developed by leading HPC performance tools groups. It motivates the advantages of the joint undertaking from both the developer and the user perspectives, and presents the design and components of the newly developed Score-P performance measurement infrastructure. Furthermore, it contains first evaluation results in comparison with existing performance tools and presents an outlook to the long-term cooperative development of the new system.

Application Execution↗

Cell source-dependent in vivo immunosuppressive properties of mesenchymal stem cells derived from the bone marrow and synovial fluid of minipigs

The in vitro differentiation and immunosuppressive capacity of mesenchymal stem cells (MSCs) derived from synovial fluid (SF-MSCs) and bone marrow extract (BM-MSCs) in an isogenic background of minipigs were comparatively analyzed in a collagen-induced arthritis (CIA) mouse model of rheumatoid arthritis (RA). The proliferation capacity and expression of pluripotent transcription factors (Oct3/4 and Sox2) were significantly (P<0.05) higher in SF-MSCs than in BM-MSCs. The differentiation capacity of SF-MSCs into adipocytes, osteocytes and neurocytes was significantly (P<0.05) lower than that of BM-MSCs, and the differentiation capacity of SF-MSCs into chondrocytes was significantly (P<0.05) higher than that of BM-MSCs. Systemic injection of BM- and SF-MSCs significantly (P<0.05) ameliorated the clinical symptoms of CIA mice, with SF-MSCs having significantly (P<0.05) higher clinical and histopathological recovery scores than BM-MSCs. Furthermore, the immunosuppressive properties of SF-MSCs in CIA mice were associated with increased levels of the anti-inflammatory cytokine interleukin (IL)-10, and decreased levels of the pro-inflammatory cytokine IL-1β and osteoclast-related sRANKL. In conclusion, SF-MSCs exhibited eminent pluripotency and differentiation capacity into chondrocytes, addition to substantial in vivo immunosuppressive capacity by elevating IL-10 and reducing IL-1β levels in CIA mice. - Highlights: • Immunosuppressive capacity of BM-, SM-, and SF-MSCs was evaluated in an RA model. • Proliferation, pluripotency and chondrogenic differentiation capacity were higher in SF-MSCs. • SF-MSCs exhibited improved therapeutic effects than BM-MSCs. • SF-MSCs may have applications as immunosuppressive therapy in autoimmune diseases.

60 APPLIED LIFE SCIENCES↗

Effects of Temporal Light Modulation on Individuals Sensitive to Pattern Glare

Solid-state lighting systems can vary widely in the degree of temporal light modulation (TLM) of their light output. TLM is known to have visual, cognitive, and behavioral effects but there are few recommendations for limits on the acceptable TLM in everyday lighting systems and there is little information concerning individual differences in sensitivity. This paper is a re-analysis of previously presented data, focusing on two subgroups in a larger sample: those scoring low or high on the Wilkins Pattern Glare Sensitivity (PGS) test, which is a validated test that identifies people at high risk of visual stress. In conclusion, the results show that the PGS groups differed in their sensitivity to TLM conditions, despite short exposures and a restricted field of view.

60 APPLIED LIFE SCIENCES↗

Efficient Speaker Verification Using Gaussian Mixture Model Component Clustering

In speaker verification (SV) systems that employ a support vector machine (SVM) classifier to make decisions on a supervector derived from Gaussian mixture model (GMM) component mean vectors, a significant portion of the computational load is involved in the calculation of the a posteriori probability of the feature vectors of the speaker under test with respect to the individual component densities of the universal background model (UBM). Further, the calculation of the sufficient statistics for the weight, mean, and covariance parameters derived from these same feature vectors also contribute a substantial amount of processing load to the SV system. In this paper, we propose a method that utilizes clusters of GMM-UBM mixture component densities in order to reduce the computational load required. In the adaptation step we score the feature vectors against the clusters and calculate the a posteriori probabilities and update the statistics exclusively for mixture components belonging to appropriate clusters. Each cluster is a grouping of multivariate normal distributions and is modeled by a single multivariate distribution. As such, the set of multivariate normal distributions representing the different clusters also form a GMM. This GMM is referred to as a hash GMM which can be considered to a lower resolution representation of the GMM-UBM. The mapping that associates the components of the hash GMM with components of the original GMM-UBM is referred to as a shortlist. This research investigates various methods of clustering the components of the GMM-UBM and forming hash GMMs. Of five different methods that are presented one method, Gaussian mixture reduction as proposed by Runnall's, easily outperformed the other methods. This method of Gaussian reduction iteratively reduces the size of a GMM by successively merging pairs of component densities. Pairs are selected for merger by using a Kullback-Leibler based metric. Using Runnal's method of reduction, we were able to achieve a factor of 2.77 reduction in a posteriori probability calculations with no loss in accuracy when the original UBM consisted of 256 component densities. When clustering was implemented with a 1024 component UBM, we achieved a computation reduction of 5 with no loss in accuracy and a reduction by a factor of 10 with less than 2.4% relative loss in accuracy.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measuring the Interestingness of Articles in a Limited User Environment

Search engines, such as Google, assign scores to news articles based on their relevancy to a query. However, not all relevant articles for the query may be interesting to a user. For example, if the article is old or yields little new information, the article would be uninteresting. Relevancy scores do not take into account what makes an article interesting, which varies from user to user. Although methods such as collaborative filtering have been shown to be effective in recommendation systems, in a limited user environment, there are not enough users that would make collaborative filtering effective. A general framework, called iScore, is presented for defining and measuring the 'interestingness' of articles, incorporating user-feedback. iScore addresses various aspects of what makes an article interesting, such as topic relevancy, uniqueness, freshness, source reputation, and writing style. It employs various methods to measure these features and uses a classifier operating on these features to recommend articles. The basic iScore configuration is shown to improve recommendation results by as much as 20%. In addition to the basic iScore features, additional features are presented to address the deficiencies of existing feature extractors, such as one that tracks multiple topics, called MTT, and a version of the Rocchio algorithm that learns its parameters online as it processes documents, called eRocchio. The inclusion of both MTT and eRocchio into iScore is shown to improve iScore recommendation results by as much as 3.1% and 5.6%, respectively. Additionally, in TREC11 Adaptive Filter Task, eRocchio is shown to be 10% better than the best filter in the last run of the task. In addition to these two major topic relevancy measures, other features are also introduced that employ language models, phrases, clustering, and changes in topics to improve recommendation results. These additional features are shown to improve recommendation results by iScore by up to 14%. Due to varying reasons that users hold regarding why an article is interesting, an online feature selection method in naive Bayes is also introduced. Online feature selection can improve recommendation results in iScore by up to 18.9%. In summary, iScore in its best configuration can outperform traditional IR techniques by as much as 50.7%. iScore and its components are evaluated in the news recommendation task using three datasets from Yahoo! News, actual users, and Digg. iScore and its components are also evaluated in the TREC Adaptive Filter task using the Reuters RCV1 corpus.

99 GENERAL AND MISCELLANEOUS↗

NOAA-20 ATMS Status: ATMS SDR Team

Data quality looks better than Suomi-NPP (Suomi National Polar-orbiting Partnership): similar biases. Smaller standard deviation of first guess departures and diagnosed observation errors. Weaker striping signal than Suomi-NPP ATMS (Advanced Technology Microwave Sounder). Improved first guess fits to: temperature observations (AMSU-A (Advanced Microwave Sounding Unit-A), CrIS (Cross-track Infrared Sounder), GPSRO (Global Positioning System Radio Occultation)); Humidity observations (MHS (Microwave Humidity Sounder), GEO CSRs (Geostationary Orbit Clear Sky Radiances)). Indicates improved accuracy of short range temperature and humidity forecasts. Neutral to slightly positive forecast scores.

Sensor Data Record (SDR)↗

Development of Digital Mock-Up for the Assessment of Dismantling Scenarios

As the number of superannuated research reactors and nuclear power plants increase, dismantling nuclear power facilities has become a big issue. However, decommissioning a nuclear facility is still a costly and possibly hazardous task. So prior to an actual decommission, what should be done foremost is to establish a proper procedure. Due to the fact that a significant difference in cost, exposure to a radiation, and safety might occur, a proper procedure is imperative for the entire engineering process. The purpose of this paper is to develop a system for evaluating the decommissioning scenarios logically and systematically. So a digital mockup system with functions such as a dismantling schedule, decommissioning costs, wastes, worker's exposure dose, and a radiation distribution was developed. Also on the basis of the quantitative information calculated from a DMU system and the data evaluated by decommissioning experts about qualitatively evaluating the items, the best decommissioning scenarios were established by using the analytic hierarchy process (AHP) method. Finally, the DMU was implemented in the thermal column of KRR-1 and adequate scenarios were provided after comparing and analyzing the two scenarios. In this paper, we developed the virtual environment of KRR-1 by using computer graphic technology and simulating the dismantling processes. The data-computing modules were also developed for quantitatively comparing the decommissioning scenarios. The decommissioning DMU system was integrated with both the VE system and the data-computing modules. In addition, we presented a decision-making method for selecting the best decommissioning scenario through the AHP. So the scenarios can be evaluated logically and quantitatively through the decommissioning DMU. As an implementation of the AHP, the plasma cutting scenario and the nibbler cutting scenario of the thermal column were prioritized. The fact that the plasma cutting scenario ranked the better than the nibbler cutting scenario is that the plasma scenario mostly got the higher scores than the nibbler scenario in the decommissioning cost and safety sections that have high weighting factors. Finally we decided that the plasma cutting scenario is appropriate to dismantle the thermal column. This study has a great meaning in that it can present a reliable scenario through the decommissioning DMU system while this work had only been done through a subjective evaluation in the past. The DMU system will be applied to the KRR-1 decommissioning project to obtain the best scenarios. We believe it will be a useful engineering tool for other nuclear facility decommissioning.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗