Search NASA⌕ Search

SEARCH · Search NASA

Results for “structure imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Concomitant Imaging Dose and Cancer Risk in Image Guided Thoracic Radiation Therapy

Purpose: Kilovoltage cone beam computed tomography (CT) (kVCBCT) imaging guidance improves the accuracy of radiation therapy but imposes an extra radiation dose to cancer patients. This study aimed to investigate concomitant imaging dose and associated cancer risk in image guided thoracic radiation therapy. Methods and Materials: The planning CT images and structure sets of 72 patients were converted to CT phantoms whose chest circumferences (C{sub chest}) were calculated retrospectively. A low-dose thorax protocol on a Varian kVCBCT scanner was simulated by a validated Monte Carlo code. Computed doses to organs and cardiac substructures (for 5 selected patients of various dimensions) were regressed as empirical functions of C{sub chest}, and associated cancer risk was calculated using the published models. The exposures to nonthoracic organs in children were also investigated. Results: The structural mean doses decreased monotonically with increasing C{sub chest}. For all 72 patients, the median doses to the heart, spinal cord, breasts, lungs, and involved chest were 1.68, 1.33, 1.64, 1.62, and 1.58 cGy/scan, respectively. Nonthoracic organs in children received 0.6 to 2.8 cGy/scan if they were directly irradiated. The mean doses to the descending aorta (1.43 ± 0.68 cGy), left atrium (1.55 ± 0.75 cGy), left ventricle (1.68 ± 0.81 cGy), and right ventricle (1.85 ± 0.84 cGy) were significantly different (P<.05) from the heart mean dose (1.73 ± 0.82 cGy). The blade shielding alleviated the exposure to nonthoracic organs in children by an order of magnitude. Conclusions: As functions of patient size, a series of models for personalized estimation of kVCBCT doses to thoracic organs and cardiac substructures have been proposed. Pediatric patients received much higher doses than did the adults, and some nonthoracic organs could be irradiated unexpectedly by the default scanning protocol. Increased cancer risks and disease adverse events in the thorax were strongly related to higher imaging doses and smaller chest dimensions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

3D Optical Coherence Tomography image processing in BISCAP: characterization of biofilm structure and properties

Abstract Motivation BISCAP is a state-of-the-art tool for automatically characterizing biofilm images obtained from Optical Coherence Tomography. Limited availability of other software tools is reported in the field. BISCAP’s first version processes 2D images only. Processing 3D images is a problem of greater scientific relevance since it deals with the entire structure of biofilms instead of their 2D slices. Results Building on the image-processing principles and algorithms proposed earlier for 2D images, these were adapted to the 3D case, and a more general implementation of BISCAP was developed. The primary goal concerns the extension of the initial methodology to incorporate the depth axis in 3D images; multiple improvements were also made to boost computational performance. The calculation of structural properties and visual outputs was extended to offer new insights into the 3D structure of biofilms. BISCAP was tested using 3D images of biofilms with different morphologies, consistently delivering accurate characterizations of 3D structures in a few minutes using standard laptop machines. Low user dependency is required for image analysis. Availability and implementation BISCAP is available from https://github.com/diogonarciso/BISCAP. All images used in the tutorials and the validation examples are available from https://web.fe.up.pt/∼fgm/biscap3d.

Narciso, Diogo A. C. (ORCID:0000000227767477)↗

MILLIMETER SOURCE 13 S IN R CrA: OBSERVATIONS OF A PROTO-HERBIG Ae SYSTEM CANDIDATE

Compelled to observe a young, intermediate mass (IM) protostar candidate, we image velocity structure in a variety of molecular lines toward a strong millimeter continuum peak, MMS 13, in the young stellar object cluster R Corona Australis. We report the detection of N{sub 2}H{sup +} (1–0) and C{sup 34}S (2–1) corresponding to a filamentary IM core coincident with a site of turbulent flow convergence and Spitzer infrared emission minimum. Several emission features including a central decay of turbulence, kinematic signatures of bulk infall, and strong winds support mass and age estimates in indicating the presence of a proto-Herbig Ae system in the region. Channeling of center velocity flow with turbulence amplification along the rotation axis drives wind generation in the system candidate.

79 ASTRONOMY AND ASTROPHYSICS↗

Enhanced Exciplex Emission of Pyrene Thin Films Doped by Perylene: Structural, Photophysical and Morphological Investigation

The present work reports on the preparation of thin films of pyrene luminophors doped by varying amounts of perylene by spin coating technique. The structural, morphological, and photophysical properties of pyrene thin films have been investigated as a function of perylene contents. X-ray diffraction studies of doped thin films show well-defined peaks, and estimated crystallite size decreases with increasing perylene content, due to the formation of closed packed crystal structure. SEM images of pure pyrene revealed smooth, and compact and separated crystals with amounts of perylene. The result of absorption spectra showed decrease in intensity with perylene content. However, the fluorescence spectra of pyrene containing higher amounts of perylene showed broad and structureless exciplex emission at 510 nm. The emission colour of pyrene luminophors tuned from blue to green by controlling the concentration of perylene. The phenomenon of change in colour was seen due to efficient excitation energy transfer from pyrene to perylene in thin films. It also found that the intensity of exciplex emission increases with increasing concentration of perylene is of high demand in fluorescent lamp as well as green organic light emitting diodes.

36 MATERIALS SCIENCE↗

DEEPER BY THE DOZEN: UNDERSTANDING THE CROSS-FIELD TEMPERATURE DISTRIBUTIONS OF CORONAL LOOPS

Spectroscopic analysis of coronal loops has revealed a variety of cross-field temperature distributions. Some loops appear to be isothermal while others require multithermal plasma. The EUV Imaging Spectrometer on Hinode has the spatial resolution and temperature coverage required for differential emission measure (DEM) analysis of coronal loops. Our results also use data from the X-Ray Telescope on Hinode as a high-temperature constraint. Of our 12 loops, two were post-flare loops with broad temperature distributions, two were narrow but not quite isothermal, and the remaining eight were in the mid range. We consider our DEM methods to be a significant advance over previous work, and it is also reassuring to learn that our findings are consistent with results available in the literature. For the quiescent loops analyzed here, 10 MK plasma, a signature of nanoflares, appears to be absent at a level of approximately two orders of magnitude down from the DEM peak. We find some evidence that warmer loops require broader DEMs. The cross-field temperatures obtained here cannot be modeled as single flux tubes. Rather, the observed loop must be composed of several or many unresolved strands. The plasma contained in each of these strands could be cooling at different rates, contributing to the multithermal nature of the observed loop pixels. An important implication of our DEM results involves observations from future instruments. Once solar telescopes can truly resolve X-ray and EUV coronal structures, these images would have to reveal the loop substructure implied by our multithermal results.

79 ASTRONOMY AND ASTROPHYSICS↗

Data for: Subsurface Interface Structure Controlling Local Electronic Properties of Epitaxial Graphene on SiC(0001)

Recently realized high-mobility semiconducting epitaxial graphene on silicon carbide, provided an important step towards integration of the graphene-based system into active components in post-silicon micro- and nano-electronics. However, the exact atomic-scale structure and the complex bonding configurations of the first epitaxial graphene carbon layer remain an open problem. Our recent report has shed new light on understanding this interface, where the external transverse electric field-dependent dynamic switching behavior of the Cbuffer-SiC bonds was observed. Here, using scanning tunneling microscopy and spectroscopy (STM and STS), we present the direct evidence of silicon (Si) vacancies at the interface and provide their distribution at the topmost reconstructed SiC(0001) layer. Experimental STM and density functional theory modeling data were used in the preparation of figures in a published article in the Journal of Physical Chemistry Letters. Files related to the figures and supplementary materials in the article are present in this dataset in .txt format.

Condensed matter imaging↗

Data for: Subsurface Interface Structure Controlling Local Electronic Properties of Epitaxial Graphene on SiC(0001)

Recently realized high-mobility semiconducting epitaxial graphene on silicon carbide, provided an important step towards integration of the graphene-based system into active components in post-silicon micro- and nano-electronics. However, the exact atomic-scale structure and the complex bonding configurations of the first epitaxial graphene carbon layer remain an open problem. Our recent report has shed new light on understanding this interface, where the external transverse electric field-dependent dynamic switching behavior of the Cbuffer-SiC bonds was observed. Here, using scanning tunneling microscopy and spectroscopy (STM and STS), we present the direct evidence of silicon (Si) vacancies at the interface and provide their distribution at the topmost reconstructed SiC(0001) layer. Experimental STM and density functional theory modeling data were used in the preparation of figures in a published article in the Journal of Physical Chemistry Letters. Files related to the figures and supplementary materials in the article are present in this dataset in .txt format.

Condensed matter imaging↗

Weighted simultaneous algebraic reconstruction technique for tomosynthesis imaging of objects with high-attenuation features

Purpose: This paper introduces a nonlinear weighting scheme into the backprojection operation within the simultaneous algebraic reconstruction technique (SART). It is designed for tomosynthesis imaging of objects with high-attenuation features in order to reduce limited angle artifacts. Methods: The algorithm estimates which projections potentially produce artifacts in a voxel. The contribution of those projections into the updating term is reduced. In order to identify those projections automatically, a four-dimensional backprojected space representation is used. Weighting coefficients are calculated based on a dissimilarity measure, evaluated in this space. For each combination of an angular view direction and a voxel position an individual weighting coefficient for the updating term is calculated. Results: The feasibility of the proposed approach is shown based on reconstructions of the following real three-dimensional tomosynthesis datasets: a mammography quality phantom, an apple with metal needles, a dried finger bone in water, and a human hand. Datasets have been acquired with a Siemens Mammomat Inspiration tomosynthesis device and reconstructed using SART with and without suggested weighting. Out-of-focus artifacts are described using line profiles and measured using standard deviation (STD) in the plane and below the plane which contains artifact-causing features. Artifacts distribution in axial direction is measured using an artifact spread function (ASF). The volumes reconstructed with the weighting scheme demonstrate the reduction of out-of-focus artifacts, lower STD (meaning reduction of artifacts), and narrower ASF compared to nonweighted SART reconstruction. It is achieved successfully for different kinds of structures: point-like structures such as phantom features, long structures such as metal needles, and fine structures such as trabecular bone structures. Conclusions: Results indicate the feasibility of the proposed algorithm to reduce typical tomosynthesis artifacts produced by high-attenuation features. The proposed algorithm assigns weighting coefficients automatically and no segmentation or tissue-classification steps are required. The algorithm can be included into various iterative reconstruction algorithms with an additive updating strategy. It can also be extended to computed tomography case with the complete set of angular data.

60 APPLIED LIFE SCIENCES↗

Dragonfly : an implementation of the expand–maximize–compress algorithm for single-particle imaging

Single-particle imaging (SPI) with X-ray free-electron lasers has the potential to change fundamentally how biomacromolecules are imaged. The structure would be derived from millions of diffraction patterns, each from a different copy of the macromolecule before it is torn apart by radiation damage. The challenges posed by the resultant data stream are staggering: millions of incomplete, noisy and un-oriented patterns have to be computationally assembled into a three-dimensional intensity map and then phase reconstructed. In this paper, the Dragonfly software package is described, based on a parallel implementation of the expand–maximize–compress reconstruction algorithm that is well suited for this task. Auxiliary modules to simulate SPI data streams are also included to assess the feasibility of proposed SPI experiments at the Linac Coherent Light Source, Stanford, California, USA.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Adaptive AFM scan speed control for high aspect ratio fast structure tracking

Improved imaging rates in Atomic Force Microscopes (AFM) are of high interest for disciplines such as life sciences and failure analysis of semiconductor wafers, where the sample topology shows high aspect ratios. Also, fast imaging is necessary to cover a large surface under investigation in reasonable times. Since AFMs are composed of mechanical components, they are associated with comparably low resonance frequencies that undermine the effort to increase the acquisition rates. In particular, high and steep structures are difficult to follow, which causes the cantilever to temporarily loose contact to or crash into the sample. Here, we report on a novel approach that does not affect the scanner dynamics, but adapts the lateral scanning speed of the scanner. The controller monitors the control error signal and, only when necessary, decreases the scan speed to allow the z-piezo more time to react to changes in the sample's topography. In this case, the overall imaging rate can be significantly increased, because a general scan speed trade-off decision is not needed and smooth areas are scanned fast. In contrast to methods trying to increase the z-piezo bandwidth, our method is a comparably simple approach that can be easily adapted to standard systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sources of and Remedies for Removing Unwanted Reflections in Millimeter Wave Images of Complex SOFI-Covered Space Shuttle Structures

In the recent years, continuous-wave near-field and lens-focused millimeter wave imaging systems have been effectively used to demonstrate their utility for producing high-resolution images of metallic structures covered with spay on foam insulation (SOFI) such as the Space Shuttle external fuel tank. However, for some specific structures a certain interference -pattern may be superimposed on the produced images. There are methods by which the influence of this unwanted interference can be reduced, such as the incorporation of an incidence .angle and the proper use of signal polarization. This paper presents the basics of this problem and describes the use of the methods for reducing this unwanted influence through specific examples.

Kharkovsky, S.↗

Metal artifact correction for x-ray computed tomography using kV and selective MV imaging

Purpose: The overall goal of this work is to improve the computed tomography (CT) image quality for patients with metal implants or fillings by completing the missing kilovoltage (kV) projection data with selectively acquired megavoltage (MV) data that do not suffer from photon starvation. When both of these imaging systems, which are available on current radiotherapy devices, are used, metal streak artifacts are avoided, and the soft-tissue contrast is restored, even for regions in which the kV data cannot contribute any information. Methods: Three image-reconstruction methods, including two filtered back-projection (FBP)-based analytic methods and one iterative method, for combining kV and MV projection data from the two on-board imaging systems of a radiotherapy device are presented in this work. The analytic reconstruction methods modify the MV data based on the information in the projection or image domains and then patch the data onto the kV projections for a FBP reconstruction. In the iterative reconstruction, the authors used dual-energy (DE) penalized weighted least-squares (PWLS) methods to simultaneously combine the kV/MV data and perform the reconstruction. Results: The authors compared kV/MV reconstructions to kV-only reconstructions using a dental phantom with fillings and a hip-implant numerical phantom. Simulation results indicated that dual-energy sinogram patch FBP and the modified dual-energy PWLS method can successfully suppress metal streak artifacts and restore information lost due to photon starvation in the kV projections. The root-mean-square errors of soft-tissue patterns obtained using combined kV/MV data are 10–15 Hounsfield units smaller than those of the kV-only images, and the structural similarity index measure also indicates a 5%–10% improvement in the image quality. The added dose from the MV scan is much less than the dose from the kV scan if a high efficiency MV detector is assumed. Conclusions: The authors have shown that it is possible to improve the image quality of kV CTs for patients with metal implants or fillings by completing the missing kV projection data with selectively acquired MV data that do not suffer from photon starvation. Numerical simulations demonstrated that dual-energy sinogram patch FBP and a modified kV/MV PWLS method can successfully suppress metal streak artifacts and restore information lost due to photon starvation in kV projections. Combined kV/MV images may permit the improved delineation of structures of interest in CT images for patients with metal implants or fillings.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

MO-F-CAMPUS-T-02: Optimizing Orientations of Hundreds of Intensity-Modulated Beams to Treat Multiple Brain Targets

Purpose: To investigate a new modulated beam orientation optimization (MBOO) approach maximizing treatment planning quality for the state-of-the-art flattening filter free (FFF) beam that has enabled rapid treatments of multiple brain targets. Methods: MBOO selects and optimizes a large number of intensity-modulated beams (400 or more) from all accessible beam angles surrounding a patient’s skull. The optimization algorithm was implemented on a standalone system that interfaced with the 3D Dicom images and structure sets. A standard published data set that consisted of 1 to 12 metastatic brain tumor combinations was selected for MBOO planning. The planning results from various coplanar and non-coplanar configurations via MBOO were then compared with the results obtained from a clinical volume modulated arc therapy (VMAT) delivery system (Truebeam RapidArc, Varian Oncology). Results: When planning a few number of targets (n<4), MBOO produced results equivalent to non-coplanar multi-arc VMAT planning in terms of target volume coverage and normal tissue sparing. For example, the 12-Gy and 4-Gy normal brain volumes for the 3-target plans differed by less than 1 mL ( 3.0 mLvs 3.8 mL; and 35.2 mL vs 36.3 mL, respectively) for MBOO versus VMAT. However, when planning a larger number of targets (n≥4), MBOO significantly reduced the dose to the normal brain as compared to VMAT, though the target volume coverage was equivalent. For example, the 12-Gy and 4-Gy normal brain volumes for the 12-target plans were 10.8 mL vs. 18.0 mL and 217.9 mL vs. 390.0 mL, respectively for the non-coplanar MBOO versus the non-coplanar VMAT treatment plans, yielding a reduction in volume of more than 60% for the case. Conclusion: MBOO is a unique approach for maximizing normal tissue sparing when treating a large number (n≥4) of brain tumors with FFF linear accelerators. Dr Ma and Dr Sahgal are currently on the board of international society of stereotactic radiosurgery. Dr Sahgal has received support for educational presentations from Elekta company.

60 APPLIED LIFE SCIENCES↗

Autocorrelation and regularization in digital images. I - Basic theory

Spatial structure occurs in remotely sensed images when the imaged scenes contain discrete objects that are identifiable in that their spectral properties are more homogeneous within than between them and other scene elements. The spatial structure introduced is manifest in statistical measures such as the autocovariance function and variogram associated with the scene, and it is possible to formulate these measures explicitly for scenes composed of simple objects of regular shapes. Digital images result from sensing scenes by an instrument with an associated point spread function (PSF). Since there is averaging over the PSF, the effect, termed regularization, induced in the image data by the instrument will influence the observable autocovariance and variogram functions of the image data. It is shown how the autocovariance or variogram of an image is a composition of the underlying scene covariance convolved with an overlap function, which is itself a convolution of the PSF. The functional form of this relationship provides an analytic basis for scene inference and eventual inversion of scene model parameters from image data.

Jupp, David L. B.↗

A new generic method for the semi-automatic extraction of river and road networks in low and mid-resolution satellite images

This paper addresses the problem of semi-automatic extraction of road or hydrographic networks in satellite images. For that purpose, we propose an approach combining concepts arising from mathematical morphology and hydrology. The method exploits both geometrical and topological characteristics of rivers/roads and their tributaries in order to reconstruct the complete networks. It assumes that the images satisfy the following two general assumptions, which are the minimum conditions for a road/river network to be identifiable and are usually verified in low- to mid-resolution satellite images: (i) visual constraint: most pixels composing the network have similar spectral signature that is distinguishable from most of the surrounding areas; (ii) geometric constraint: a line is a region that is relatively long and narrow, compared with other objects in the image. While this approach fully exploits local (roads/rivers are modeled as elongated regions with a smooth spectral signature in the image and a maximum width) and global (they are structured like a tree) characteristics of the networks, further directional information about the image structures is incorporated. Namely, an appropriate anisotropic metric is designed by using both the characteristic features of the target network and the eigen-decomposition of the gradient structure tensor of the image. Following, the geodesic propagation from a given network seed with this metric is combined with hydrological operators for overland flow simulation to extract the paths which contain most line evidence and identify them with the target network.

47 OTHER INSTRUMENTATION↗

Estimating Belowground Carbon Stocks in Isolated Wetlands of the Northern Everglades Watershed, Central Florida, Using Ground Penetrating Radar and Aerial Imagery

Abstract Peat soils store a large fraction of the global soil carbon (C) pool and comprise 95% of wetland C stocks. While isolated freshwater wetlands in temperate and tropical biomes account for more than 20% of the global peatland C stock, most studies of wetland soil C have occurred in expansive peatlands in northern boreal and subarctic biomes. Furthermore, the contribution of small depressional wetlands in comparison to larger wetland systems in these environments is very uncertain. Given the fact that these wetlands are numerous and variable in terms of their internal geometry, innovative methods are needed for properly estimating belowground C stocks and their overall C contribution to the landscape. In this study, we use a combination of ground penetrating radar (GPR), aerial imagery, and direct measurements (coring) in conjunction with C core analysis to develop a relation between C stock and surface area, and estimate the contribution of subtropical depressional wetlands to the total C stock of pine flatwoods at the Disney Wilderness Preserve (DWP), Florida. Additionally, GPR surveys were able to image collapse structures underneath the peat basin of depressional wetlands, depicting lithological controls on the formation of depressional wetlands at the DWP. Results indicate the importance of depressional wetlands as critical contributors to the landscape C budget at the DWP and the potential of GPR‐based approaches for (1) rapidly and noninvasively estimating the contribution of depressional wetlands to regional C stocks and (2) evaluating the formational processes of depressional wetlands.

McClellan, Matthew↗

Synthesis and characterization of porous polydimethylsiloxane structures with adjustable porosity and pore morphology using emulsion templating technique

Abstract Porous polydimethylsiloxane (PDMS) framework with adjustable pore structures has been fabricated by polymerization of the continuous phase in the emulsion templates. Different types of surfactants, including nonionic (Triton X‐100), cationic (Benzalkonium chloride), anionic (sodium dodecyl sulfate), and silicone‐based block copolymer were used to stabilize the water‐in‐oil emulsion system. Deionized water with a wide range of internal phases varying from 10% to 60% by weight was employed to make the low internal phase emulsion and medium internal phase emulsion. The effect of surfactant type, surfactant concentration, and the internal phase volume on the stability of the emulsion, pore morphology, and pore size distribution was explored. The stability of the emulsion was investigated by comparing the pore morphology of the cured sample at different set times, such as 0, 6, and 72 h. Scanning electron microscopy was employed for the characterization of the porous structures. The image analysis was conducted, and the pore size distribution, porosity, and open‐cell ratio of each sample were calculated. Interconnected pores have been seen in the porous PDMS made from emulsions with an internal phase larger than 30%. The results demonstrated that the frequency of open‐cell pores and the pore size is dependent on the surfactant types.

Abshirini, Mohammad↗

Magnetic Properties and Photocatalytic Behavior of Co Co-doped BiFeO{sub 3}:Er

The multiferroic materials Bi{sub 0.95}Er{sub 0.05}Fe{sub 1−x}Co{sub x} O{sub 3} (x = 0, 0.01, 0.03, and 0.05) are synthesized by solvothermal method. X-ray diffraction pattern is used to confirm the formation of rhombohedral crystal structure. TEM images show agglomerated nanosize particles. With the concentration of Co, a red shift is observed in the charge transfer transition of O{sub 2p}-Fe{sub 3d} band and band gap decreases. At higher concentration of Co, the saturation magnetization enhances and coercivity also varies with the concentration of Co. The photocatalytic degradation of methylene blue is evaluated under the visible light with the assistance of H{sub 2}O{sub 2}. With the increase in Co concentration, the photocatalytic activity decreases. The main species responsible for the degradation is found out using scavengers like ammonium oxalate, silver nitrate, p-benzoquinone, and tert-butyl-alcohol. The possible mechanism for the degradation of dye is explained.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗