Search NASA⌕ Search

SEARCH · Search NASA

Results for “test system test”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

LANSCE Wire Scanner System Prototype: Switchyard Test

On November 19, 2011, the beam diagnostics team of Los Alamos National Laboratory's LANSCE accelerator facility conducted a test of a prototype wire scanner system for future deployment within the accelerator's switchyard area. The primary focus of this test was to demonstrate the wire scanner control system's ability to extend its functionality beyond acquiring lower energy linac beam profile measurements to acquiring data in the switchyard. This study summarizes the features and performance characteristics of the electronic and mechanical implementation of this system with details focusing on the test results.

42 ENGINEERING↗

Evaluation of Carbon Dioxide Capture From Existing Coal Fired Plants by Hybrid Sorption Using Solid Sorbents

A novel hybrid solid sorbent technology for CO₂ capture and separation from coal combustion-derived flue gas was evaluated. The technology – Capture of CO₂ by Hybrid Sorption (CACHYS™) – is a solid sorbent technology based on the following ideas: 1) reduction of energy for sorbent regeneration, 2) utilization of novel process chemistry, 3) contactor conditions that minimize sorbent-CO₂ heat of reaction and promote fast CO₂ capture, and 4) low-cost method of heat management. This report provides key information developed during the course of the project that includes sorbent performance, energy for sorbent regeneration, physical properties of the sorbent, the integration of process components, sizing of equipment, and overall capital and operational cost of the integrated CACHYS™ system. Seven sorbent formulations were prepared and evaluated at the lab-scale for energy requirements and CO₂ capture performance. Sorbent heat of regeneration ranged from 30-80 kJ/mol CO₂ and was found to be dependent on process conditions. Two sorbent formulations (designated HCK-4 & HCK-7) were down-selected for additional fixed-bed testing. Additional testing involved subjecting the sorbents to 100 continuous cycles in the fixed-bed reactor to determine performance as a function of time. The working capacity achieved for HCK-4 sorbent ranged from 5.5-8.0 g CO₂/100 g sorbent, while the HCK-7 typically ranged from 8.0-10.0 g CO₂/100 g sorbent. Overall, there was no deterioration in capacity with continuous cycling for either sorbent. The CACHYS™ bench-scale testing system designed and fabricated under this award consists of a dual circulating fluidized-bed adsorber and a moving-bed regenerator. The system takes a flue gas slipstream from the University of North Dakota’s coal-fired steam plant. Prior to being sent to the adsorber, the flue gas is scrubbed to remove SO₂ and particulate. During parametric testing of the adsorber, CO₂ capture achieved using the 2-bed configuration with recirculation in both beds was 65-70% with a high flue gas CO₂ loading (~7%) and up to 85% with a low flue gas CO₂ loading (~4%). A sorbent regenerator system consisting of a pre-heater, desorber, and cooler is used to heat the CO₂-rich sorbent with direct and indirect steam producing a nearly 100% pure stream of CO₂. Parametric testing of the regenerator system demonstrated the impact of process conditions on both desorption rate and the heat of regeneration. Clear evidence of the use of specific process conditions that lower the overall energy of desorption was identified. This observation validates measurements made at the laboratory-scale. Several longer-term continuous tests were conducted to evaluate the performance of the sorbent/process as a function of time. Using a 2-bed configuration, sustained capture efficiency of 40-60% with a high flue gas CO₂ loading (~8%) and 70-80% with a low flue gas CO₂ loading (~4%) were achieved. However, sorbent working capacity was found to be considerably lower than laboratory-scale measurements. The low working capacity is attributed to insufficient sorbent/gas contact time in the adsorber. Sorbent properties that had a significant impact on CO₂ capture performance were identified. The results show that controlling these sorbent properties substantially improves CO₂ capture performance, with preliminary estimates indicating that relative improvement of ~30% is possible. Testing culminated with an operationally trouble-free test of 15 hours with sustainable performance. Overall, several practical strategies to increase performance of the sorbent and process were identified. The initial technical and economic assessment of the CACHYS™ process estimated the cost of CO2 capture was $36.19/ton with a 48.6% increase in levelized cost of electricity (LCOE) for the 550 MWe net plant. Using additional data gathered over the course of the project, and with revised technical and economic assumptions, the estimated cost of CO₂ capture with the CACHYS™ process is $39/ton (only includes the cost of the CO2 capture system) with an increase in LCOE of 55.9%. Overall, CACHYS™ represents a significant improvement over the benchmark MEA system, and has demonstrated progress towards achieving DOE’s goals for CO₂ capture technologies.

01 COAL, LIGNITE, AND PEAT↗

A Cyber Threat Mitigation Approach For Wide Area Control of SVCs using Stability Monitoring

We propose a stability monitoring approach for the mitigation of cyber threats directed at the wide area control (WAC) system used for coordinated control of Flexible AC Transmission Systems (FACTS) used for power oscillation damping (POD) of active power flow on inter-area tie lines. The approach involves monitoring the modes of the active power oscillation on an inter-area tie line using the Matrix Pencil (MP) method. We use the stability characteristics of the observed modes as a proxy for the presence of destabilizing cyber threats. We monitor the system modes to determine whether any destabilizing modes appear after the WAC system engages to control the POD. If the WAC signal exacerbates the POD performance, the FACTS falls back to POD using local measurements. The proposed approach does not require an expansive system-wide view of the network. We simulate replay, control integrity, and timing attacks for a test system and present results that demonstrate the performance of the SM approach for mitigation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Localized Cyber Threat Mitigation Approach For Wide Area Control of FACTS

We propose a localized oscillation amplitude monitoring (OAM) method for the mitigation of cyber threats directed at the wide area control (WAC) system used to coordinate control of Flexible AC Transmission Systems (FACTS) for power oscillation damping (POD) of active power flow on inter-area tie lines. The method involves monitoring the inter-area tie line active power oscillation amplitude over a sliding window. We use system instability - inferred from oscillation amplitudes growing instead of damping - as evidence of an indication of a malfunction in the WAC of FACTS, possibly indicative of a cyber attack. Monitoring the presence of such a growth allows us to determine whether any destabilizing behaviors appear after the WAC system engages to control the POD. If the WAC signal increases the oscillation amplitude over time, thereby diminishing the POD performance, the FACTS falls back to POD using local measurements. The proposed method does not require an expansive system-wide view of the network. We simulate replay, control integrity, and timing attacks for a test system and present results that demonstrate the performance of the OAM method for mitigation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Stability of Transactive Energy Market-Based Power Distribution System Under Data Integrity Attack

Future smart power distribution system with multiple active consumers and aggregators exchanging real-time electricity pricing and electricity consumption information over a communication network is prone to cyberattack. The goal of this paper is to understand the impact of attacks on pricing/load signals on the physical grid within a transactive energy market framework. First, this paper models the interaction between real-time electricity price and total energy demand in the form of a discrete time nonlinear autonomous dynamical system. Second, equilibrium electricity price and energy demand associated with this coupled dynamical system is derived and conditions for bounded input bounded output (BIBO) stability are identified. Third, a BIBO stable algorithm to design real-time electricity pricing scheme from a techno-economic perspective is developed. Finally, the impact of various levels of false data injection (FDI) attack on price of electricity, demand, and distribution system voltage is investigated. The proposed model is analyzed using simulations on the IEEE 69-bus test system and the impact of FDI attack on both electricity price/demand and distribution grid voltage is quantified. In conclusion, this paper shows that impact of FDI attack on electricity prices is more severe than an attack on electricity demand.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Quantifying the Economic and Grid Reliability Impacts of Improved Wind Power Forecasting

Wind power forecasting is an important tool in power system operations to address variability and uncertainty. Accurately doing so is important to reducing the occurrence and length of curtailment, enhancing market efficiency, and improving the operational reliability of the bulk power system. This research quantifies the value of wind power forecasting improvements in the IEEE 118-bus test system as modified to emulate the generation mixes of Midcontinent, California, and New England independent system operator balancing authority areas. To measure the economic value, a commercially available production cost modeling tool was used to simulate the multi-timescale unit commitment (UC) and economic dispatch process for calculating the cost savings and curtailment reductions. To measure the reliability improvements, an in-house tool, FESTIV, was used to calculate the system's area control error and the North American Electric Reliability Corporation Control Performance Standard 2. The approach allowed scientific reproducibility of results and cross-validation of the tools. A total of 270 scenarios were evaluated to accommodate the variation of three factors: generation mix, wind penetration level, and wind fore-casting improvements. The modified IEEE 118-bus systems utilized 1 year of data at multiple timescales, including the day-ahead UC, 4-hour-ahead UC, and 5-min real-time dispatch. The value of improved wind power forecasting was found to be strongly tied to the conventional generation mix, existence of energy storage devices, and the penetration level of wind energy. The simulation results demonstrate that wind power forecasting brings clear benefits to power system operations.

17 WIND ENERGY↗

Evaluation Report on "The Department's Unclassified Cyber Security Program"

Industry experts report that security challenges and threats are continually evolving as malicious activity has become more web-based and attackers are able to rapidly adapt their attack methods. In addition, the number of data breaches continues to rise. In an effort to mitigate and address threats and protect valuable information, the Department of Energy anticipated spending about $275 million in Fiscal Year (FY) 2009 to implement cyber security measures necessary to protect its information technology resources. These systems and data are designed to support the Department's mission and business lines of energy security, nuclear security, scientific discovery and innovation, and environmental responsibility. The Federal Information Security Management Act of 2002 (FISMA) provides direction to agencies on the management and oversight of information security risks, including design and implementation of controls to protect Federal information and systems. As required by FISMA, the Office of Inspector General conducts an annual independent evaluation to determine whether the Department's unclassified cyber security program adequately protects its information systems and data. This memorandum and the attached report present the results of our evaluation for FY 2009. The Department continued to make incremental improvements in its unclassified cyber security program. Our evaluation disclosed that most sites had taken action to address weaknesses previously identified in our FY 2008 evaluation report. They improved certification and accreditation of systems; strengthened configuration management of networks and systems; performed independent assessments; and, developed and/or refined certain policies and procedures. In addition, the Department instituted a centralized incident response organization designed to eliminate duplicative efforts throughout the Department. As we have noted in previous reports, the Department continued to maintain strong network perimeter defenses against malicious intruders and other externals threats. These are positive accomplishments. However, in our judgment, additional action is required to further enhance the Department's unclassified cyber security program and help reduce risks to its systems and data. For example, our current review identified opportunities for improvements in areas such as security planning and testing, systems inventory, access controls, and configuration management. In particular, we issued a number of findings at sites managed by the National Nuclear Security Administration (NNSA). We also identified weaknesses across various Department program elements. Issues that warrant further attention include: (1) Weaknesses such as outdated security plans and not completing annual security control self-assessments were identified at several sites; (2) The Department had not yet resolved systems inventory issues and had yet to deploy a complex-wide automated asset management tool to help track information technology resources and identify interfaces between systems or networks; (3) Although certain improvements had been made to enhance access controls, we noted deficiencies such as a lack of periodic account reviews and inadequate password management at a number of sites; and (4) Previously identified weaknesses in configuration management had been corrected, however, we found problems related to weak administrator account settings and failure to install software patches, as well as incomplete implementation of the Federal Desktop Core Configuration. These internal control weaknesses existed, at least in part, because certain cyber security roles and responsibilities were not clearly delineated. Program officials also had not effectively performed monitoring and review activities essential for evaluating the adequacy of cyber security performance. In some cases, officials had not ensured that weaknesses discovered during audits and other evaluations were recorded and tracked to resolution in the organizations' Plans of Action and Milestones. Our testing disclosed that about 39 percent of existing corrective action milestones had missed estimated remediation dates, with many exceeding planned completion dates by at least one year. As a consequence, the risk of compromise to the Department's information and systems remained higher than necessary. To assist the continuing efforts to improve, we made several recommendations designed to help the Department's managers to strengthen the unclassified cyber security program and, thereby, protect its computer resources from unauthorized modification, loss, or disclosure of information. Due to security considerations, information on specific vulnerabilities and locations has been omitted from this report. Management officials at the sites evaluated were provided with detailed information regarding identified vulnerabilities, and, in many instances, initiated corrective actions.

99 GENERAL AND MISCELLANEOUS↗

Smart Infrared Inspection System Field Operational Test (Final Report)

The Smart InfraRed Inspection System (SIRIS) is a tool designed to assist inspectors in determining which vehicles passing through the SIRIS system are in need of further inspection by measuring the thermal data from the wheel components. As a vehicle enters the system, infrared cameras on the road measure temperatures of the brakes, tires, and wheel bearings on both wheel ends of commercial motor vehicles (CMVs) in motion. This thermal data is then presented to enforcement personal inside of the inspection station on a user friendly interface. Vehicles that are suspected to have a violation are automatically alerted to the enforcement staff. The main goal of the SIRIS field operational test (FOT) was to collect data to evaluate the performance of the prototype system and determine the viability of such a system being used for commercial motor vehicle enforcement. From March 2010 to September 2010, ORNL facilitated the SIRIS FOT at the Greene County Inspection Station (IS) in Greeneville, Tennessee. During the course of the FOT, 413 CMVs were given a North American Standard (NAS) Level-1 inspection. Of those 413 CMVs, 384 were subjected to a SIRIS screening. A total of 36 (9.38%) of the vehicles were flagged by SIRIS as having one or more thermal issues; with brakes issues making up 33 (91.67%) of those. Of the 36 vehicles flagged as having thermal issues, 31 (86.11%) were found to have a violation and 30 (83.33%) of those vehicles were placed out-of-service (OOS). Overall the enforcement personnel who have used SIRIS for screening purposes have had positive feedback on the potential of SIRIS. With improvements in detection algorithms and stability, the system will be beneficial to the CMV enforcement community and increase overall trooper productivity by accurately identifying a higher percentage of CMVs to be placed OOS with minimal error. No future evaluation of SIRIS has been deemed necessary and specifications for a production system will soon be drafted.

brake system↗

Force Modulator System

Many metal parts manufacturers use large metal presses to shape sheet metal into finished products like car body parts, jet wing and fuselage surfaces, etc. These metal presses take sheet metal and - with enormous force - reshape the metal into a fully formed part in a manner of seconds. Although highly efficient, the forces involved in forming metal parts also damage the press itself, limit the metals used in part production, slow press operations and, when not properly controlled, cause the manufacture of large volumes of defective metal parts. To date, the metal-forming industry has not been able to develop a metal-holding technology that allows full control of press forces during the part forming process. This is of particular importance in the automotive lightweighting efforts under way in the US automotive manufacturing marketplace. Metalforming Controls Technology Inc. (MC2) has developed a patented press control system called the Force Modulator that has the ability to control these press forces, allowing a breakthrough in stamping process control. The technology includes a series of hydraulic cylinders that provide controlled tonnage at all points in the forming process. At the same time, the unique cylinder design allows for the generation of very high levels of clamping forces (very high tonnages) in very small spaces; a requirement for forming medium and large panels out of HSS and AHSS. Successful production application of these systems testing at multiple stamping operations - including Ford and Chrysler - has validated the capabilities and economic benefits of the system. Although this technology has been adopted in a number of stamping operations, one of the primary barriers to faster adoption and application of this technology in HSS projects is system cost. The cost issue has surfaced because the systems currently in use are built for each individual die as a custom application, thus driving higher tooling costs. This project proposed to better marry the die-specific Force Modulator technology with stamping presses in the form of a press cushion. This system would be designed to operate the binder ring for multiple parts, thus cutting the per-die cost of the technology. This study reports the results of technology field application. This project produced the following conclusions: (1) The Force Modulator system is capable of operating at very high tempos in the stamping environment; (2) The company can generate substantial, controlled holding tonnage (binder ring pressure) necessary to hold high strength steel parts for proper formation during draw operations; (3) A single system can be designed to operate with a family of parts, thus significantly reducing the per-die cost of a FM system; (4) High strength steel parts made with these systems appear to show significant quality improvements; (5) The amounts of steel required to make these parts is typically less than the amounts required with traditional blank-holding technologies; and (6) This technology will aid in the use of higher strength steels in auto and truck production, thus reducing weight and improving fuel efficiency.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Determination of Thermoelectric Module Efficiency A Survey

The development of thermoelectrics (TE) for energy conversion is in the transition phase from laboratory research to device development. There is an increasing demand to accurately determine the module efficiency, especially for the power generation mode. For many thermoelectrics, the figure of merit, ZT, of the material sometimes cannot be fully realized at the device level. Reliable efficiency testing of thermoelectric modules is important to assess the device ZT and provide the end-users with realistic values on how much power can be generated under specific conditions. We conducted a general survey of efficiency testing devices and their performance. The results indicated the lack of industry standards and test procedures. This study included a commercial test system and several laboratory systems. Most systems are based on the heat flow meter method and some are based on the Harman method. They are usually reproducible in evaluating thermoelectric modules. However, cross-checking among different systems often showed large errors that are likely caused by unaccounted heat loss and thermal resistance. Efficiency testing is an important area for the thermoelectric community to focus on. A follow-up international standardization effort is planned.

efficiency↗

Formulation of an experimental substructure model using a Craig-Bampton based transmission simulator

An experimental–analytical substructuring is attractive when there is motivation to replace one or more system subcomponents with an experimental model. This experimentally derived substructure can then be coupled to finite element models of the rest of the structure to predict the system response. The transmission simulator method couples a fixture to the component of interest during a vibration test in order to improve the experimental model for the component. The transmission simulator is then subtracted from the tested system to produce the experimental component. This method reduces ill-conditioning by imposing a least squares fit of constraints between substructure modal coordinates to connect substructures, instead of directly connecting physical interface degrees of freedom. This paper presents an alternative means of deriving the experimental substructure model, in which a Craig–Bampton representation of the transmission simulator is created and subtracted from the experimental measurements. The corresponding modal basis of the transmission simulator is described by the fixed-interface modes, rather than free modes that were used in the original approach. Moreover, these modes do a better job of representing the shape of the transmission simulator as it responds within the experimental system, leading to more accurate results using fewer modes. The new approach is demonstrated using a simple finite element model based example with a redundant interface.

42 ENGINEERING↗

Permeability scaling relationships of volcanic tuff from core to field scale measurements

A recent chemical explosive test in P-Tunnel at the Nevada National Security Site, Nevada, USA, was conducted to better understand how signals propagate from explosions in the subsurface. A primary signal of interest is the migration of gases that can be used to differentiate chemical from nuclear explosions. Gas migration is highly dependent on the rock permeability which is notoriously difficult to determine experimentally in the field due to a potentially large dependence on the scale over which measurements are made. Here, we present pre-explosion permeability estimates to characterize the geologic units surrounding the recent test. Permeability measurements were made at three scales of increasing size: core samples (≈2 cm), borehole packer system tests (≈1 m), and a pre-shot cavity pressurization test (> 10 m) across ten tuff units. Permeability estimates based on core measurements showed little difference from borehole packer tests. However, permeability in most rock units calibrated from cavity pressurization tests resulted in higher permeability estimates by up to two orders of magnitude. Here, we demonstrate that the scale of the measurement significantly impacts the characterization efforts of hydraulic properties in volcanic tuff, and that local-scale measurements (< 10 m scale) do not incorporate enough heterogeneity to accurately predict field-scale flow and mass transport.

Environmental sciences↗

On some categories of Monge-Ampere systems of equations

The paper looks at differential-geometric structures associated with Monge-Ampere systems of equations on manifolds and how they can be applied in the reduction of these equations. The category of Monge-Ampere systems of equations is investigated; its morphisms are changes of independent and dependent variables. Some subcategories of this category are also studied. The main emphasis is on subcategories of equations of locally equivalent triangular and semitriangular systems, systems that are linear with respect to derivatives (semilinear systems), systems with constant coefficients, and also complete differential systems. Tests, which can be verified effectively, are proved; these make it possible to establish whether a given system of Monge-Ampere equations belongs to the subcategories listed above. As corollaries, conditions for a Monge-Ampere system to be locally reducible to a single first- or second-order equation are obtained. Bibliography: 14 titles.

97 MATHEMATICS AND COMPUTING↗

Multi-Objective PMU Allocation for Resilient Power System Monitoring

Phasor measurement units (PMUs) enable better system monitoring and security enhancement in smart grids. In order to enhance power system resilience against outages and blackouts caused by extreme weather events or man-made attacks, it remains a major challenge to determine the optimal number and location of PMUs. In this paper, a multi-objective resilient PMU placement (MORPP) problem is formulated, and solved by a modified Teaching-Learning-Based optimization (MO-TLBO) algorithm. Three objectives are considered in the MORPP problem, minimizing the number of PMUs, maximizing the system observability, and minimizing the voltage stability index. The effectiveness of the proposed method is validated through testing on IEEE 14-bus, 30-bus, and 118-bus test systems. The advantage of the MO-TLBO-based MORPP is demonstrated through the comparison with other methods in the literature, in terms of iteration number, optimality and time of convergence.

Multi-Objective Optimization↗

End-to-end Analytics for Grid Arch Design & All-hazard Assessment

Resiliency, reliability, and security of the next-generation smart grid depend upon leveraging advanced communication and computing technologies, integrating them with physical power systems, and developing real-time, fast, data-based applications to help in wide-area monitoring and control of the grid. Using a high sampling data rate from phasor measurement units (PMUs) to develop applications has opened the door to achieving the next-generation grid requirements. The North American Synchrophasor Initiative Network (NASPlnet) was developed in 2007-09 to create a standard and guide for PMU data exchanges. With the advancement in both networking and grid requirements, it is necessary to evaluate the performance of different NASPInet versions and their impact on applications. Therefore, we need a cyber-power cosimulation framework that supports very large-scale co-simulation capable of running in parallel, high-performance computing platforms and capturing real-life network behavior. This work presents a cyber-physical co-simulation testbed using NS3 to model the communication network, GridPACK to model the power grid, and HELICS as a co-simulation engine. Comparative analysis of latency in synchrophasor networks and a performance evaluation of a power system stabilizer application based on PMU data in an Institute of Electrical and Electronics Engineers 39-bus test system is presented using this co-simulation testbed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A Review of Quantum Computing Technologies in Power System Optimization

As modern power grids increasingly integrate variable renewable generation, distributed energy resources, and energy storage systems, classical optimization techniques are facing unprecedented challenges. This review examines the emerging application of quantum computing to overcome these challenges in power system optimization, including optimal power flow (OPF), unit commitment (UC), economic dispatch (ED), and intelligent switching and topology optimization (IS-TO). Recent research has introduced various quantum methodologies—such as gate-based, annealing-based, variational algorithms, and quantum-inspired algorithms—to address the combinatorial complexity inherent in grid reconfiguration and energy management. The review summaries the quantum algorithms, quantum devices and the power system test cases, highlighting hybrid quantum–classical strategies that leverage the complementary strengths of both paradigms. Some quantum advantages have been observed, including theoretical speedup, accurate simulation results, scalable qubit usage, efficient QUBO mapping. In particular, the review emphasizes the importance of integrating quantum optimization techniques with classical control frameworks, these hybrid approaches demonstrate the potential to improve real-time grid management and operational reliability. A significant portion of the analysis is devoted to the practical limitations of current quantum devices. Present-day quantum hardware, operating in the noisy intermediate-scale quantum (NISQ) era, remains highly sensitive to noise and limited in qubit connectivity, which constrains the scale and accuracy of implemented algorithms. The review delves into specific challenges such as the need for qubit-efficient encoding techniques and error mitigation strategies that are critical for handling real-world grid optimization problems. In addition, the work draws attention to the performance discrepancies between theoretical quantum speedups and experimental validations, underscoring the importance of rigorous benchmark studies using representative power grid test cases. In summary, this review highlights both the promise and limitations of quantum computing for power system optimization. It provides a comprehensive overview of the state-of-the-art technologies, categorizes recent advancements in algorithm design, and discusses practical considerations for implementation, and serves as an informative resource on current research. Future research directions include developing robust hybrid frameworks, advancing qubit-efficient formulations, and scaling up experimental demonstrations to confirm the theoretical advantages of quantum methods in large-scale power system operations.

24 POWER TRANSMISSION AND DISTRIBUTION↗

RE-INTEGRATE EMT Simulation Tool: Input Data Processing Layer for Bulk Power System

This paper introduces an advanced input data processing layer for EMT simulations of large-scale bulk power systems. The paper proposes two versions of the RE-INTEGRATE EMT simulation tool, RE-INTEGRATE Gen-0 and RE-INTEGRATE Gen-1, which are developed to enhance simulation generalizability, scalability, and accuracy. The framework leverages a generic class design for components to incorporate linear equations, which are generated by discretizing the Differential-Algebraic Equations (DAEs) that represent the dynamics of the components. In addition, the framework employs a parsing algorithm that parses a power system’s raw and dyr files to generate a connectivity graph which is then traversed to form the overall system’s dynamics. The proposed input data processing layer is used to simulate the IEEE 39-bus test system. The obtained results demonstrate the framework’s capability to achieve simulation scalability and accuracy. Further, the results indicate that EMT simulations performed using the proposed automations can effectively handle complex grid configurations.

Mishra, Rahul [ORNL] (ORCID:0000000328205932)↗

Flue gas cleanup using the Moving-Bed Copper Oxide Process

The use of copper oxide on a support had been envisioned as a gas cleanup technique to remove sulfur dioxide (SO{sub 2}) and nitric oxides (NO{sub x}) from flue gas produced by the combustion of coal for electric power generation. In general, dry, regenerable flue gas cleanup techniques that use a sorbent can have various advantages, such as simultaneous removal of pollutants, production of a salable by-product, and low costs when compared to commercially available wet scrubbing technology. Due to the temperature of reaction, the placement of the process into an advanced power system could actually increase the thermal efficiency of the plant. The Moving-Bed Copper Oxide Process is capable of simultaneously removing sulfur oxides and nitric oxides within the reactor system. In this regenerable sorbent technique, the use of the copper oxide sorbent was originally in a fluidized bed, but the more recent effort developed the use of the sorbent in a moving-bed reactor design. A pilot facility or life-cycle test system was constructed so that an integrated testing of the sorbent over absorption/regeneration cycles could be conducted. A parametric study of the total process was then performed where all process steps, including absorption and regeneration, were continuously operated and experimentally evaluated. The parametric effects, including absorption temperature, sorbent and gas residence times, inlet SO{sub 2} and NO{sub x} concentration, and flyash loadings, on removal efficiencies and overall operational performance were determined. Although some of the research results have not been previously published because of previous collaborative restrictions, a summary of these past findings is presented in this communication. Additionally, the potential use of the process for criteria pollutant removal in oxy-firing of fossil fuel for carbon sequestration purposes is discussed.

20 FOSSIL-FUELED POWER PLANTS↗