Search NASA⌕ Search

SEARCH · Search NASA

Results for “testing and evaluation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Evaluation of the DC bus link capacitors and power transistor modules in the qualification testing of PV inverters

To achieve useful, fair, and cost-effective design qualification and type approval testing for PV inverters, two procedures were developed and demonstrated to evaluate the bus link capacitors and power transistor—and where applicable, its module—for long-term reliability. We evaluate the inverter under simulated use conditions with heat run tests to find the highest operating temperatures reached by these components. The procedures are demonstrated in this study with a 4-kVA class string inverter. The maximum temperature of the DC bus link capacitors was determined to be 76.4°C when the ambient temperature was at the inverter's maximum rated temperature of 60°C with derating occurring. On the other hand, the power transistor module's maximum temperature using the heat sink temperature as the index, 92.6°C, occurred in an ambient of 40.8°C when derating was not occurring. The conditions found for upper temperatures exhibited by these components are, respectively, proposed for implementation in the dry heat and thermal cycling tests in the IEC 62093 “Power conversion equipment for photovoltaic systems – Design qualification testing” international standard draft so that the levels applied in the tests are in proportion to those experienced in the field. Finally as a result, fairer evaluation of inverter reliability is realized.

14 SOLAR ENERGY↗

A High-Voltage High-Current Benchtop Test Stand for Solid-State Switch Testing at the SNS

Solid-state switches already replaced thyratrons in the SNS extraction kicker power supplies, offering improved efficiency and reliability. However, recent supply chain disruptions, combined with a self-firing issue, led us to explore alternative solutions. A vendor-developed MOS-Gated Thyristor switch was introduced but ultimately failed during testing. To investigate the failure and assess possible improvements, a benchtop test stand was constructed to evaluate the performance of a single stage board. This test stand features a Pulse Forming Network (PFN) that operates at 6 kV and 6 kA, with a repetition rate exceeding 60 Hz, simulating real operational conditions. By utilizing this setup, we seek to gain a better understanding of the failure mechanisms, refine the switch designs, and ultimately develop a more reliable alternative for the extraction kicker power supplies.

Bullman, Austin [ORNL]↗

Sirius Irradiation Experiments and Post-Irradiation Examinations for Nuclear Thermal Propulsion

Nuclear Thermal Propulsion (NTP) systems hold promise in reducing transit times for exploration of the solar system by both crewed and uncrewed missions. NTP systems currently under investigation include a once-through high temperature gas-cooled fission reactor to provide thermal energy to heat the coolant which also serves as the propellant. The fuel systems of angular UN fuel particles dispersed in a matrix of W/Re, creating a ceramic and metallic composite or cermet, has been irradiated in Idaho National Laboratory’s (INL) Transient Reactor Test Facility (TREAT) enabling evaluation of these materials under representative nuclear heating rates (~95 K/s) and peak temperatures (~2527 K). These tests named Sirius-1 (UN-W/Re), have been irradiated and this paper will present post-irradiation examination results. The Sirius-1 test produced cracks in the fuel specimen and spalling of surface material. Uranium soot was found on the inner wall of the irradiation capsule indicating loss of some fissile material from the fuel specimen. Spalling from the surfaces was also noted upon visual inspection. Uranium diffusion from the fuel particles resulted in the formation of U/Re phases and edge features producing a laminar microstructure.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Crystalline Silicotitanate Batch Contact Testing with Ba, Ca, Pb, and Sr

Washington River Protection Solutions is working to support initial production of immobilized low-activity waste (LAW) by feeding Hanford tank supernate from tank farms to the Hanford Waste Treatment and Immobilization Plant (WTP) LAW Facility. This goal incorporates the design of a Tank Side Cesium Removal system, which filters tank waste supernate to remove suspended solids and then removes Cs by processing it through crystalline silicotitanate (CST) ion exchange media manufactured by Honeywell UOP, LLC. The 137 Cs-depleted product is intended to be sent to the WTP for vitrification. Processing of actual tank waste supernate showed effectively complete uptake of Sr and Ba by CST and significant uptake of Ca. Further, Campbell et al. (2019) analyzed CST post-column testing and found significant (>1E-2 mmoles/g) uptake of Ca and Pb along with some Ba, Cd, Fe, Sr, and U. This led to concern that selected metals, particularly the +2 cations, Ca, Sr, Ba, and Pb may be consuming Cs exchange sites and possibly reducing CST capacity for Cs. Exchange of +2 cations was assumed to be associated with the M(OH) + species for the metal (M) ion in the caustic solution. A series of batch contact testing was conducted to evaluate the exchange behavior of Ba, Ca, Pb, and Sr onto CST. The Cs exchange behavior was also tested as a benchmark for direct comparisons. The CST was provided in the sodium form by Honeywell UOP, as IONSIV TM R9140-B, Lot 2002009604, 18 x 50 mesh. A <30-mesh aliquot was collected to match the sieve fraction expected for use in upcoming small column test configurations. Kinetic exchange rate and isotherms were measured at metal concentrations benchmarked from the AP-107 tank waste feed composition and as limited by the metal solubility in the alkaline solution. Two simplified matrices were tested: 1) 1.0 M NaOH/4.6 M NaNO 3 and 2) 0.1 M NaOH/5.5 M NaNO 3 ; these matrices represented the expected 5.6 M Na concentration of process feed and served to address the hydroxide concentration effect on exchange behavior.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Iodine Removal in the DFLAW Flow-Sheet

In support of the WTP project, off-gas system and regulatory testing has been conducted previously on the DM1200 pilot melter equipped with a prototypical off-gas system installed at The Catholic University of America’s Vitreous State Laboratory (VSL). During the regulatory tests, an AC-S test bed filled with Kombisorb BAT 37 was included in the prototypical off-gas system and evaluated for response to HLW and LAW exhaust streams. Offline testing and small-scale testing of that media were also conducted. Testing demonstrated that a temperature rise occurred in the activated carbon media when water vapor was first introduced to virgin Kombisorb BAT 37, in response to high nitrogen oxide concentrations, and in response to the presence of organic compounds. Conditioning of the test bed by gradually increasing the NOx concentration prior to the introduction of organics was found to be an important operational strategy for preventing larger temperature excursions. However, no mercury was present in the exhaust stream during DM1200 testing and therefore comparable test data for mercury removal efficiency or temperature response of the carbon media in the presence of mercury were not collected in the DM1200 tests. In view of the need for data on mercury removal performance, BNI contracted with Atkins and the VSL to install and operate a suitable test system at VSL to collect the required data. That testing was designed to assess the performance of Kombisorb BAT-37 and the guard bed material, Sofnolime RG, for simulated melter exhaust streams that contain the highest concentrations of mercury, nitrogen oxides, acid gases, and organic compounds expected in WTP LAW melter exhaust. During shakedown testing with the new system, however, it became evident that a number of issues with Sofnolime RG as the guard bed material would render it unsuitable for this application. BNI subsequently determined that the guard bed was redundant for removal of acid gases since they could be adequately removed by the SBS and WESP. However, since the guard bed material was also credited with significant iodine removal , there was a need for a replacement material that would adequately perform that role. BNI identified several candidate media but performance data in gas compositions that are representative of the WTP LAW off-gas were not available. Accordingly, there was a need to test and evaluate the performance of these candidate media prior to performing the originally-planned tests. To that end, small scale tests were conducted to assess the performance of various adsorbents in simulated melter exhaust streams that contain mercury, iodine, nitrogen oxides, acid gases, and acetonitrile, which are expected to be present in WTP LAW melter exhaust.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Conservative Numerical Schemes with Optimal Dispersive Wave Relations: Part II. Numerical Evaluations

A new energy and enstrophy conserving scheme (EEC) for the shallow water equations is proposed and evaluated using a suite of test cases over the global spherical or bounded domain. The evaluation is organized around a set of pre-defined properties: accuracy of individual operators, accuracy of the whole scheme, conservation of key quantities, control of the divergence variable, representation of the energy and enstrophy spectra, and simulation of nonlinear dynamics. The results confirm that the scheme is between the first and second order accurate, and conserves the total energy and potential enstrophy up to the time truncation errors. Here, the scheme is capable of producing more physically realistic energy and enstrophy spectra, indicating that it can help prevent the unphysical energy cascade towards the finest resolvable scales. With an optimal representation of the dispersive wave relations, the scheme is able to keep the flow close to being non-divergent, and maintain the geostrophically balanced structures with large-scale geophysical flows over long-term simulations.

54 ENVIRONMENTAL SCIENCES↗

Unraveling capacity fading in lithium-ion batteries using advanced cyclic tests: A real-world approach

Battery lifespan estimation is essential for effective battery management systems, aiding users and manufacturers in strategic planning. However, accurately estimating battery capacity is complex, owing to diverse capacity fading phenomena tied to factors such as temperature, charge-discharge rate, and rest period duration. In this work, we present an innovative approach that integrates real-world driving behaviors into cyclic testing. Unlike conventional methods that lack rest periods and involve fixed charge-discharge rates, our approach involves 1000 unique test cycles tailored to specific objectives and applications, capturing the nuanced effects of temperature, charge-discharge rate, and rest duration on capacity fading. This yields comprehensive insights into cell-level battery degradation, unveiling growth patterns of the solid electrolyte interface (SEI) layer and lithium plating, influenced by cyclic test parameters. Here, the results yield critical empirical relations for evaluating capacity fading under specific testing conditions.

25 ENERGY STORAGE↗

Hanford Double Shell Waste Tank Corrosion Studies FY2020 (Final Report)

For fiscal year (FY) 2020, the Savannah River National Laboratory (SRNL) focused on three experimental tasks related to Hanford Double Shell Tank (DST) chemistry and integrity. The first task focused on understanding risk of corrosion due to formation of either continuous layers or discrete patches of deposits on the tanks’ inner sidewalls and bottoms. The second task studied vapor space corrosion (VSC) of the secondary liner using two commercially available vapor corrosion inhibitors (VCIs) at manufacturer recommended dosages. Finally, the third task investigated the long-term open circuit potential (OCP) drift for mill-scale coupons, coupons with polished surfaces, and partial mill-scale coupons that were exposed to tank waste simulants. Additional tests were performed to evaluate the OCP drift as a function of the quantity and composition of organic compounds added to the simulant. A test that was included in the matrix that established the new chemistry limits for tank corrosion, but was previously unreported, was presented and reviewed as well.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Closing the Loop on Automotive Carbon Fiber Prepreg Manufacturing Scrap

The project demonstrated how to “close the loop” on carbon fiber by integrating industrial carbon fiber scrap into new functional components in an automotive lightweighting application. The project serves as a validation of discontinuous recycled carbon fiber in a commercial context, while generating comprehensive material data throughout the production chain. To this end, the project exhibited increasing complexity as material evaluation progressed from benchtop to commercial scale through full-scale part production, with key material properties thoroughly characterized throughout the process. Of particular focus was the form of the fiber that was fed into compounding, as recycled fiber has historically been problematic to feed at commercial-scale. Carbon fiber is energy-intensive to manufacture, so reuse of existing fiber material can reduce costs and increase sustainability. Additionally, by integrating recovered short fiber into a thermoplastic, regrind processes can be used to provide feedstock for later generations of product. While regrind plastics are not “infinitely recyclable”, reusing the manufacturing scrap over several generations of products can greatly increase material sustainability and lower the fractional embodied energy of each successive product. As such, this project supports the IACMI technical goals of (1) 25% lower carbon fiber-reinforced polymer (CFRP) cost, (2) 50% reduction in CFRP embodied energy, and (3) 80% composite recyclability into useful products. The initial stage of the project involved down selecting surface treatment (sizing) chemistries. Sizing evaluations were performed on Vartega’s chemically recycled intermediate modulus fiber along with standard modulus dry scrap which was oversized with sizing provided by Michelman. More dramatic improvements from sizing were found on the standard rather than the intermediate modulus fibers. The strength of the chemically recycled individual fibers were evaluated by Michelman and ORNL through single fiber testing and found to be comparable to similarly evaluated virgin fibers. UDRI’s mechanical testing on injection molded test specimens identified similar mechanical properties and fiber distribution relative to benchmark specimens. Additional surface chemistry tests and visualizations were performed by the Colorado School of Mines to confirm close conformance between the benchmark and recycled-fiber specimens. As the mechanical test results exceeded the 80% threshold established as the go/no-go(GNG), the project scale was increased to use commercial-scale equipment that would both better characterize the manufacturing utility of the target product format and allow qualitative assessment of a complex commercial part. An upscaled compounding evaluation was performed with a 27 mm twin-screw compounding extruding using oversized standard modulus fibers that were formatted to improve bulk solids transfer. The project team anticipated that milestone mechanical benchmarks could be achieved given the favorable performance of the sized standard modulus material identified in the initial micro-compounding trials. While the mechanical performance did meet the milestone target for that phase of the project, mechanical properties for this standard modulus-based compound were still less than those of the Ford specification. To compare the performance, the project team oversized intermediate modulus dry fibers and compounded them with the project resin at BASF using a 40 mm compounder. Test specimen mechanical performance exceeded the targets laid out in both the project milestone and the Ford specification. A series of prototype parts were successfully molded, albeit with instances of short shot components due to the high thermal conductivity of the carbon fiber compared to glass fiber for which the prototype tool was designed for. The project demonstrated that recycled carbon fiber is a viable option in fiber reinforced compound, providing greatly increased strength and modulus for applications that require them. The “agglomerated” format that facilitated effective bulk solids transfer of recovered fiber showed promise for industrial application.

36 MATERIALS SCIENCE↗

Conceptual Neutronics Scoping for Ramp Testing in the Advanced Test Reactor

With the closer of the Halden Boiling Water Reactor in 2018, the global capacity for in-reactor power ramp testing has been lost. As such tests provide valuable data for understanding pellet-cladding interaction (PCI) phenomena, finding new facilities for ramp testing is of interest to the United States Accident-Tolerant Fuel (ATF) Program. Several options at Idaho National Laboratory (INL) are being evaluated for adding ramp test capabilities. In the Transient Reactor Test Facility (TREAT), one option is testing inside a Transient Water Irradiation System in TREAT (TWIST) capsule. In the Advanced Test Reactor (ATR), one option under consideration is testing in an I-Loop toward the outer edge of the core. Another is testing in Loop-2A, located in the Center Flux Trap (CFT) of the ATR. In this paper, we examine the conceptual scoping for the Loop-2A experiment known as ATF-2Ramp.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Conceptual Neutronics Scoping for Ramp Testing in the Advanced Test Reactor

With the closure of the Halden Boiling Water Reactor in 2018, the global capacity for in-reactor power ramp testing has been lost. As such tests provide valuable data for understanding pellet-cladding interaction (PCI) phenomena, finding new facilities for ramp testing is of interest to the United States Accident-Tolerant Fuel (ATF) Program. Several options at Idaho National Laboratory (INL) are being evaluated for adding ramp test capabilities. In the Transient Reactor Test Facility (TREAT), one option is testing inside a Transient Water Irradiation System in TREAT (TWIST) capsule. In the Advanced Test Reactor (ATR), one option under consideration is testing in an I-Loop toward the outer edge of the core. Another is testing in Loop-2A, located in the Center Flux Trap (CFT) of the ATR. In this paper, we examine the conceptual scoping for the Loop-2A experiment known as ATF-2Ramp.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

In Vitro Thrombogenicity Testing of Biomaterials in a Dynamic Flow Loop: Effects of Length and Quantity of Test Samples

Abstract The results of in vitro dynamic thrombogenicity testing of biomaterials and medical devices can be significantly impacted by test conditions. To develop and standardize a robust dynamic in vitro thrombogenicity tool, the key test parameters need to be appropriately evaluated and optimized. We used a flow loop test system previously developed in our laboratory to investigate the effects of sample length and the number of samples per test loop on the thrombogenicity results. Porcine blood heparinized to a donor-specific target concentration was recirculated at room temperature through polyvinyl chloride (PVC) tubing loops containing test materials for 1 h at 200 mL/min. Four test materials (polytetrafluoroethylene (PTFE), latex, PVC, and silicone) with various thrombotic potentials in two sample lengths (12 and 18 cm) were examined. For the 12-cm long materials, two different test configurations (one and two samples per loop) were compared. Thrombogenicity was assessed through percent thrombus surface coverage, thrombus weight, and platelet count reduction in the blood. The test system was able to effectively differentiate the thrombogenicity profile of the materials (latex > silicone > PVC ≥ PTFE) at all test configurations. Increasing test sample length by 50% did not significantly impact the test results as both 12 and 18 cm sample lengths were shown to equally differentiate thrombotic potentials between the materials. The addition of a second test sample to each loop did not increase the test sensitivity and may produce confounding results, and thus a single test sample per loop is recommended.

Engineering↗

Parametric Design Study of a Power Electronics Package for Improving Solder Joint Reliability

The lifetime of a power electronics package is, to a large extent, determined by the reliability of its bonded interfaces under major loading conditions in an operational environment. Based on the application-level requirements of the package, bonded interface material is selected based on the results obtained from accelerated tests such as thermal cycling and power cycling. In addition to evaluating the reliability through accelerated tests, it is important to consider the impact of other component layers on the thermomechanical performance of the interface material, both from a material and geometric perspective. The co-efficient of thermal expansion (CTE) mismatch introduced by the use of different materials within a package and its structural design plays a critical role in determining the interface material reliability. In this paper, we present the results of a parametric modeling study of a power electronics package under thermal cycling in which the materials and geometric design of the different component layers were varied with respect to a baseline design to understand their impact on the reliability of the interface material. We chose the volume-averaged strain energy density per cycle computed at the corner region of the interface material as the metric for the reliability comparisons. Our results indicate that in addition to the CTE mismatch, the stiffness of individual component layers has a major impact on reliability. Among the different baseplates that we studied, aluminum silicon-carbide baseplates offered superior reliability over their copper and aluminum counterparts. We also found that the magnitude of the impact of stiffness variation—amongst the adjacent layers—on the reliability of the solder joint is dependent on the inherent CTE mismatch between the layers.

47 OTHER INSTRUMENTATION↗

Evaluation of Cathode Materials with Lithium-Metal Anodes: Baseline Performance and Protocol Standardization of Coin Cells

The collaborative evaluation of electrode materials across multiple research entities requires standardized electrochemical testing protocols to produce reliable, one-to-one comparisons between different systems of interest. Similar to the work done by Long et al. on protocol standardization for coin-cell testing with graphite anodes [J. Electrochem. Soc., 163, A2999, (2016)], here we introduce two standardized testing protocols designed to quickly evaluate important electrochemical properties of cathode materials using lithium-metal anodes. The two protocols measure kinetic and thermodynamic capacity losses, rate- and voltage-dependent cycling capacities, instabilities at high voltage and high cycling rate, and overpotentials at various states of charge. We then apply these protocols to four commercially available cathode materials to establish benchmark performance metrics that can be used to screen and evaluate new cathode materials.

25 ENERGY STORAGE↗

Phasor-Measurement-Unit-Based Data Analytics Using Digital Twin and PhasorAnalytics Software

A major objective of this project was to apply GE’s commercial machine learning and data analytics toolsets to large-scale, real-world, anonymized Phasor Measurement Unit (PMU) datasets in order to extract signatures, correlated and/or causal factors, and precursor patterns associated with significant power system phenomena. The project had a particular emphasis on extraction of insights relevant to asset health monitoring, real-time load modeling and cybersecurity monitoring. Additionally, the team was directed to undertake a comprehensive data quality analysis for the provided datasets and encouraged to estimate the ‘machine-learning readiness’ of the datasets by documenting any major obstacles to the application of commercial machine learning algorithms. To accomplish the aforementioned objectives, the project team’s work centered around the identification of key event signatures and application of the identified event signatures for event detection and event classification. The industry-validated, semi-supervised machine learning strategy employed for event signature identification involved several major tasks, including data-preprocessing, generation of an overabundance of features, normal data identification, normality modeling, and event signature identification through a methodical, quantitative ranking of features in order of relevance to each studied event type. Throughout the project, data quality issues and mitigation techniques were investigated. In this report, insights are provided regarding the readiness of the provided synchrophasor datasets for application of machine learning and data analytics. The methodologies employed for this technical strategy are summarized in this report. With regards to data preprocessing and feature generation, the provided Training and Test Datasets were ingested into GE’s big data environment. Subsequently, the team applied bad data cleansing and data imputation scripts, event detection scripts, and application programming interfaces (APIs) to the datasets for convenient data access. The project team completed development and validation of dozens of physics-based, statistics-based and transformation-based feature functions used for the extraction of over 60 synchrophasor features. Using a new parallel feature generation technology developed on this project, over 60 features have been rapidly generated for the full two years’ worth of Training and Test Dataset data associated with both the Eastern and Western interconnects. Even accommodating for temporal down-sampling inherent to the feature extraction procedure, this parallel feature generation activity resulted in a massive feature set with a storage requirement approximately equal to that of the raw training dataset itself. With regards to normal data identification and normality modeling, a normality model was built using the feature data extracted from the Training Dataset and iteratively refined subsequent to incremental adjustments and expansions of the Training Dataset feature data. With respect to event characterization and signature identification, an event signature identification pipeline was developed and used in conjunction with the normality model to identify over 15 event signatures for key event categories within the Training Dataset. The identified event signatures were used to characterize hundreds of key events in terms of relative severity, duration, and location of the event. An investigation was undertaken to identify correlated and causal factors involved in transformer events. A separate investigation into temporal trends in ring-down analysis results was undertaken to determine possible associations between system dynamics and various other factors such as loading, season or year. To validate the identified event signatures, additional work was undertaken to develop signature-based anomaly detection and classification tools suitable for convenient application to the synchrophasor datasets. The anomaly detection and classification tools, suitable for online application, were then applied to the entirety of the Eastern Interconnect Training and Test Datasets. Performance of the event detection and classification tools was evaluated upon receipt of the Test Dataset event logs (i.e., the labels for events contained in the Test Dataset), and promising results were obtained despite several challenges (documented herein) associated with application of supervised or semi-supervised machine learning methods to large-scale, anonymized datasets. Finally, the detection and classification tools were used to detect, classify, and characterize thousands of new events not included in the original event logs provided by the DOE within both the Training and Test Datasets.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Parametric Design Study of a Power Electronics Package

The lifetime of a power electronics package is, to a large extent, determined by the reliability of its bonded interfaces under major loading conditions in an operational environment. Based on the application-level requirements of the package, bonded interface material is selected based on the results obtained from accelerated tests such as thermal cycling and power cycling. In addition to evaluating the reliability through accelerated tests, it is important to consider the impact of other component layers on the thermomechanical performance of the interface material, both from a material and geometric perspective. The co-efficient of thermal expansion (CTE) mismatch introduced by the use of different materials within a package and its structural design plays a critical role in determining the interface material reliability. In this paper, we present the results of a parametric modeling study of a power electronics package under thermal cycling in which the materials and geometric design of the different component layers were varied with respect to a baseline design to understand their impact on the reliability of the interface material. We chose the volume-averaged strain energy density per cycle computed at the corner region of the interface material as the metric for the reliability comparisons. Our results indicate that in addition to the CTE mismatch, the stiffness of individual component layers has a major impact on reliability. Among the different baseplates that we studied, aluminum silicon-carbide baseplates offered superior reliability over their copper and aluminum counterparts. We also found that the magnitude of the impact of stiffness variation—amongst the adjacent layers—on the reliability of the solder joint is dependent on the inherent CTE mismatch between the layers.