Search NASA⌕ Search

SEARCH · Search NASA

Results for “time of flight”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Instrument design for an inertial confinement fusion ion temperature imager

A mix of contaminant mass is a known, performance-limiting factor for laser-driven inertial confinement fusion (ICF). It has also recently been shown that the contaminant mass is not necessarily in thermal equilibrium with the deuterium–tritium plasma. Contaminant mass temperature is one of the dominant uncertainties in contaminant mass estimates. The MixIT diagnostic is a new and potentially transformative diagnostic, capable of spatially resolving ion temperature. The approach combines principles of neutron time-of-flight and neutron imaging diagnostics. The information from the MixIT diagnostic can be used to optimize ICF target and laser drive designs as well as provide key constraints on ICF radiation-hydrodynamic simulations that are critical to contaminant mass estimates. This work details the design and optimization of the major components of the MixIT diagnostic: the neutron aperture, the neutron detector (scintillator), and the recording system.

47 OTHER INSTRUMENTATION↗

The Vacuum Cherenkov Detector (VCD) for γ-ray measurements in inertial confinement fusion experiments

Inertial confinement fusion experiments at both the National Ignition Facility (NIF) and the Laboratory for Laser Energetics OMEGA laser facility currently utilize Cherenkov detectors, with fused silica as the Cherenkov medium. At the NIF, the Quartz Cherenkov Detectors improve the precision of neutron time-of-flight measurements; and at OMEGA, the Diagnostic for Areal Density provides measurements of capsule shell areal densities. An inherent property of fused silica is the radiator’s relatively low energy threshold for Cherenkov photon production (E threshold < 1 MeV), making it advantageous over gas-based Cherenkov detectors for experiments requiring low-energy γ detection. The Vacuum Cherenkov Detector (VCD) has been specifically designed for efficient detection of low energy γ’s. Its primary use is in implosion experiments, which will study reactions relevant to stellar and big-bang nucleosynthesis, such as T( 4 He,γ) 7 Li, 4 He( 3 He,γ) 7 Be, and 12 C(p,γ) 13 N. Further, the VCD is compatible with LLE’s standard Ten-Inch Manipulator diagnostic insertion module. This work will outline the design and characterization of the VCD as well as provide results from recent experiments conducted at the OMEGA laser facility.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Determination of single-crystal elastic moduli of Li RE F 4 ( RE =Y, Gd, and Tb) by resonant ultrasound spectroscopy

The tetragonal fluoro-scheelite Li RE F 4 compounds (RE = rare earth) have been shown to exhibit a variety of useful optical and magnetic properties. While LiYF 4 has been widely studied, many of the fundamental thermodynamic properties of other members of this family remain unknown. Here, we report the complete elastic tensors (C ij ) of single-crystalline LiYF 4 , LiTbF 4 , and LiGdF 4 using resonant ultrasound spectroscopy and density functional theory (DFT). Here we compare the results for LiYF 4 with prior experimental results using time-of-flight ultrasound methods. This is the first report, however, of the experimental elastic tensors of LiTbF 4 and LiGdF 4 . The present results point to a softening of the elastic moduli of the Li RE F 4 system when Y is replaced by the larger ionic radius of Tb or Gd. Furthermore, we find that just 0.3% doping with Nd on the Y site also leads to a slight softening of the moduli. The variation of the elastic moduli as a function of temperature up to 216°C was also measured. A nearly linear softening of all seven independent elastic moduli was observed with increasing temperature. Phonon dispersions and phonon density of states obtained by DFT support the experimental finding of a significantly higher sound velocity due to lighter Y atoms in LiYF 4 , as compared to heavier LiTbF 4 and LiGdF 4 .

36 MATERIALS SCIENCE↗

Comparing the kinetics of ionized and neutral atoms from single and multi-element laser-produced plasmas

In this work, kinetics of ion and neutral atom emission features were compared for nanosecond laser-produced plasmas generated from several metal targets (i.e., Al, Ti, Zr, Nb, Ta) and an alloy containing all of these as principal alloying elements. Plasmas were produced by focusing 6 ns, 1064 nm pulses from an Nd:YAG laser on the targets of interest in a vacuum. A Faraday cup was used for collecting ion temporal features while spatially and temporally resolved emission spectroscopy was used for measuring the optical time of flight of various neutral atomic transitions. Our results highlight that most probable ion and atom velocities decay with increasing atomic mass. Trends for ions from the alloy target represent a weighted average where all ions contribute. For both ions and atoms, velocities decrease with increasing heat of vaporization and melting temperature, consistent with the thermal mechanisms that contribute to nanosecond laser ablation. Kinetic energies for neutral atoms from pure metal targets have some variability with atomic mass, whereas kinetic energies for atoms from the alloy target are more similar. These more similar kinetic energies observed for neutral atoms in the multi-element plasma may be attributed to collisions between species from all elements in the Knudsen layer.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Mass-selected ion–molecule cluster beam apparatus for ultrafast photofragmentation studies

We describe an apparatus for investigating the excited-state dissociation dynamics of mass-selected ion–molecule clusters by mass-resolving and detecting photofragment-ions and neutrals, in coincidence, using an ultrafast laser operating at high repetition rates. The apparatus comprises a source that generates ion–molecule clusters, a time-of-flight spectrometer, and a mass filter that selects the desired anions, and a linear-plus-quadratic reflectron mass spectrometer that discriminates the fragment anions after the femtosecond laser excites the clusters. The fragment neutrals and anions are then captured by two channeltron detectors. The apparatus performance is tested by measuring the photofragments: I – , CF 3 I – , and neutrals from photoexcitation of the ion–molecule cluster CF 3 I·I – using femtosecond UV laser pulses with a wavelength of 266 nm. Here, the experimental results are compared with our ground state and excited state electronic structure calculations as well as the existing results and calculations, with particular attention to the generation mechanism of the anion fragments and dissociation channels of the ion–molecule cluster CF 3 I·I – in the charge-transfer excited state.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Reliable operation of Cr 2 O 3 :Mg/ $β$-Ga 2 O 3 p–n heterojunction diodes at 600 °C

Beta gallium oxide (β-Ga 2 O 3 )-based semiconductor heterojunctions have recently demonstrated improved performance at high voltages and elevated temperatures and are, thus, promising for applications in power electronic devices and harsh environment sensors. However, the long-term reliability of these ultra-wideband gap (UWBG) semiconductor devices remains barely addressed and may be strongly influenced by chemical reactions at the p–n heterojunction interface. Here, we experimentally demonstrate operation and evaluate the reliability of Cr 2 O 3 :Mg/β-Ga 2 O 3 p–n heterojunction diodes during extended operation at 600 °C, as well as after 30 repeated cycles between 25 and 550 °C. The calculated pO 2 -temperature phase stability diagram of the Ga-Cr-O material system predicts that Ga 2 O 3 and Cr 2 O 3 should remain thermodynamically stable in contact with each other over a wide range of oxygen pressures and operating temperatures. The fabricated Cr 2 O 3 :Mg/β-Ga 2 O 3 p–n heterojunction diodes show room-temperature on/off ratios >104 at ±5 V and a breakdown voltage (V Br ) of -390 V. The leakage current increases with increasing temperature up to 600 °C, which is attributed to Poole–Frenkel emission with a trap barrier height of 0.19 eV. Over the course of a 140-h thermal soak at 600 °C, both the device turn-on voltage and on-state resistance increase from 1.08 V and 5.34 mΩ cm 2 to 1.59 V and 7.1 mΩ cm 2 , respectively. This increase is attributed to the accumulation of Mg and MgO at the Cr 2 O 3 /Ga 2 O 3 interface as observed from the time-of-flight secondary ion mass spectrometry analysis. These findings inform future design strategies of UWBG semiconductor devices for harsh environment operation and underscore the need for further reliability assessments for β-Ga 2 O 3 -based devices.

36 MATERIALS SCIENCE↗

An experimental and computational view of the photoionization of diol–water clusters

In the interstellar medium, diols and other prebiotic molecules adsorb onto icy mantles surrounding dust grains. Water in the ice may affect the reactivity and photoionization of these diols. Ethylene glycol (EG), 1,2-propylene glycol, and 1,3-propylene glycol clusters with water clusters were used as a proxy to study these interactions. The diol–water clusters were generated in a continuous supersonic molecular beam, photoionized by synchrotron-based vacuum ultraviolet light from the Advanced Light Source, and subsequently detected by reflectron time-of-flight mass spectrometry. The appearance energies for the detected clusters were determined from the mass spectra, collected at increasing photon energy. Clusters of both diol fragments and unfragmented diols with water were detected. The lowest energy geometry optimized conformers for the observed EG–water clusters and EG fragment–water clusters have been visualized using density functional theory (DFT), providing insight into hydrogen bonding networks and how these affect fragmentation and appearance energy. As the number of water molecules clustered around EG fragments (m/z 31 and 32) increased, the appearance energy for the cluster decreased, indicating a stabilization by water. This trend was supported by DFT calculations. Fragment clusters from 1,2-propylene glycol exhibited a similar trend, but with a smaller energy decrease, and no trend was observed from 1,3-propylene glycol. In conclusion, we discuss and suggest that the reactivity and photoionization of diols in the presence of water depend on the size of the diol, the location of the hydroxyl group, and the number of waters clustered around the diol.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Comparison of Mg-based liquid metal ion sources for scalable focused-ion-implantation doping of GaN

We compare the suitability of various magnesium-based liquid metal alloy ion sources (LMAISs) for scalable focused-ion-beam (FIB) implantation doping of GaN. We consider GaMg, MgSO 4 $\bullet$7H 2 O, MgZn, AlMg, and AuMgSi alloys. Although issues of oxidation (GaMg), decomposition (MgSO 4 $\bullet$7H 2 O), and excessive vapor pressure (MgZn and AlMg) were encountered, the AuMgSi alloy LMAIS operating in a Wien-filtered FIB column emits all Mg isotopes in singly and doubly charged ionization states. We discuss the operating conditions to achieve <20 nm spot size Mg FIB implantation and present Mg depth profile data from time-of-flight secondary ion mass spectrometry. We also provide insight into implantation damage and recovery based on cathodoluminescence spectroscopy before and after rapid thermal processing. Prospects for incorporating the Mg LMAIS into high-power electronic device fabrication are also discussed.

36 MATERIALS SCIENCE↗

Using real-time nuclear activation detectors for measuring neutron yields from D(D, T)n reactions on the national ignition facility (NIF)

The National Ignition Facility (NIF) has 48 Real-Time Nuclear Activation Detectors distributed around the target chamber capable of measuring deuterium-triton reaction neutron yields with high precision. Here, in this work, we extend this functionality to deuterium–deuterium (DD) reaction neutrons using a nuclear reaction that occurs in the detector’s scintillator material. The corresponding decay of the activated material has a very short half-life of 5 s, which necessitates rapid data collection immediately following an experiment. In this regime, dead time can be very high (>50%) adding significant uncertainty to the measurement. To combat this, we have developed a dead time model that can self-consistently describe the measured data. Initial results show reasonable agreement (within 20%) with DD neutron yields from neutron time-of-flight spectrometers.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Reduced trap state density in AlGaN/GaN HEMTs with low-temperature CVD-grown BN gate dielectric

In this Letter, low-temperature (400 °C) chemical vapor deposition-grown boron nitride (BN) was investigated as the gate dielectric for AlGaN/GaN metal–insulator–semiconductor high electron mobility transistors (MISHEMTs) on a Si substrate. Comprehensive characterizations using x-ray photoelectron spectroscopy, reflection electron energy loss spectroscopy, atomic force microscope, high-resolution transmission electron microscopy, and time-of-flight secondary ion mass spectrometry were conducted to analyze the deposited BN dielectric. Compared with conventional Schottky-gate HEMTs, the MISHEMTs exhibited significantly enhanced performance with 3 orders of magnitude lower reverse gate leakage current, a lower off-state current of 1 × 10−7 mA/mm, a higher on/off current ratio of 108, and lower on-resistance of 5.40 Ω mm. The frequency-dependent conductance measurement was performed to analyze the BN/HEMT interface, unveiling a low interface trap state density (Dit) on the order of 5 × 1011–6 × 1011 cm−2 eV−1. This work shows the effectiveness of low-temperature BN dielectrics and their potential for advancing GaN MISHEMTs toward high-performance power and RF electronics applications.

Physics↗

Gallium oxide (Ga 2 O 3 ) energy dependent scintillation response to fast neutrons and flash gamma-rays

Gallium oxide is a newly emerged ultrawide bandgap (4.9 eV) semiconductor that is suitable as a combined electronics and radiation detection platform. We have experimentally demonstrated fast neutron and gamma-ray scintillation from Czochralski-grown β-Ga 2 O 3 in a recent series (October 2023) of experiments at the unmoderated pulsed neutron spallation source located at the Los Alamos Neutron Science Center. Using the neutron time-of-flight (TOF) technique and a fast-gated intensified CCD camera, we observed energy-dependent neutron scintillation for neutron energies ranging from 1 to 400 MeV, including the 14.1 MeV neutron energy relevant to D–T fusion. Neutron flux is quantified and calibrated by cascading the scintillator after the fission chamber, enabling a detailed analysis of temporal and energy-dependent characteristics of the scintillation events. Further, a pronounced scintillation signal from the spallation gamma flash with a temporal full width of half maximum of ~4 ns is indicative of the material’s rapid response. Neutron energy dependent scintillation is observed using the TOF method at a 22.6-m distance from the neutron source. These results highlight the possibility of developing a Ga 2 O 3 based fusion neutron diagnostic platform integrated with both scintillation and electronics functions on the integrated chip scale.

47 OTHER INSTRUMENTATION↗

Predissociation-based measurements of bond dissociation energies: US 2 , OUS, and USe

The uranium-containing molecules US 2 , OUS, and USe have been investigated using a pulsed laser ablation supersonic beam molecular source with time-of-flight mass spectrometric detection. Spectra have been recorded using the resonant two-photon ionization method over the spectroscopic range from 277 to 238 nm. These species have a myriad of excited electronic states in this spectroscopic region, leading to spectra that are highly congested and appear quasicontinuous. Sharp predissociation thresholds are observed, allowing precise bond dissociation energies to be measured. In the case of the triatomic molecules, it was necessary to use one laser for excitation and a delayed laser for ionization in order to observe a sharp predissociation threshold that allowed a precise bond dissociation energy to be measured. The resulting thermochemical values are D 0 (SU-S) = 4.910 ± 0.003 eV, D 0 (OU-S) = 5.035 ± 0.004 eV, and D 0 (USe) = 4.609 ± 0.009 eV. These results provide the first measurement of D 0 (USe) and reduce the error limits in the previous values of D 0 (SU-S) and D 0 (OU-S) by a factor of more than 70.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Delineation of the impact on temporal behaviors of off-axis photoemission in an ultrafast electron microscope

Efforts to push the spatiotemporal imaging-resolution limits of femtosecond laser-driven ultrafast electron microscopes (UEMs) to the combined angstrom–fs range will benefit from stable sources capable of generating high bunch charges. Recent demonstrations of unconventional off-axis photoemitting geometries are promising, but connections to the observed onset of structural dynamics are yet to be established. Here we use the in-situ photoexcitation of coherent phonons to quantify the relative time-of-flight (r-TOF) of photoelectron packets generated from the Ni Wehnelt aperture and from a Ta cathode set-back from the aperture plane. We further support the UEM experiments with particle-tracing simulations of the precise electron-gun architecture and photoemitting geometries. In this way, we measure discernible shifts in electron-packet TOF of tens of picoseconds for the two photoemitting surfaces. Furthermore, these shifts arise from the impact that the Wehnelt-aperture off-axis orientation has on the electron-momentum distribution, which modifies both the collection efficiency and the temporal-packet distribution relative to on-axis emission. Future needs are identified; we expect this and other developments in UEM electron-gun configuration to expand the range of material phenomena that can be directly imaged on scales commensurate with fundamental structural dynamics.

47 OTHER INSTRUMENTATION↗

Design and performance of a magnetic bottle electron spectrometer for high-energy photoelectron spectroscopy

We describe the design and performance of a magnetic bottle electron spectrometer (MBES) for high-energy electron spectroscopy. Our design features a 2 m long electron drift tube and electrostatic retardation lens, achieving sub-electronvolt (eV) electron kinetic energy resolution for high energy (several hundred eV) electrons with a close to 4π collection solid angle. A segmented anode electron detector enables the simultaneous collection of photoelectron spectra in high resolution and high collection efficiency modes. This versatile instrument is installed at the time-resolved molecular and optical sciences instrument at the Linac Coherent Light Source x-ray free-electron laser (XFEL). In this paper, we demonstrate its high resolution, collection efficiency, and spatial selectivity in measurements where it is coupled to an XFEL source. These combined characteristics are designed to enable high-resolution time-resolved measurements using x-ray photoelectron, absorption, and Auger–Meitner spectroscopy. We also describe the pervasive artifact in MBES time-of-flight spectra that arises from a periodic modulation in electron collection efficiency and present a robust analysis procedure for its removal.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cavity-enhanced high-order harmonic generation for high-performance time-resolved photoemission experiments

Recent breakthroughs in high repetition-rate extreme ultraviolet (XUV) light sources and photoelectron analyzers have led to dramatic advances in the performance of time-resolved photoemission experiments. In this perspective article, we discuss the application of cavity-enhanced high-order harmonic generation, with repetition rates exceeding 10 MHz, to photoemission experiments using advanced endstations incorporating time-of-flight photoelectron analyzers. We discuss recent results, perspective on future areas for further technological improvement, and the wide array of science enabled by ultrafast XUV photoemission experiments, now in a qualitatively new regime.

Allison, Thomas K. (ORCID:0000000302898830)↗

Local charge-screening and polarization switching in a ferroelectric ionic-superconductor

For ferroelectric ionic-conductors, polarization switching is complicated by the interplay between ion mobility and charge screening effects. When the ionic charge carriers also play a key role in the domain reversal, such as in Rb-doped KTiOPO 4 (RKTP), a higher level of complexity is introduced. RKTP provides an ideal platform for investigating the relationship between ionic conductivity and polarization reversal because its highly anisotropic crystal properties allow selective modification of material characteristics through diffusive cation doping. Here, we use indiffused Ba/K doping to create a significant increase in the ionic conductivity. Time-of-flight secondary ion mass spectrometry is employed to map Ba/K doping within the RKTP crystal and correlate it to changes in ionic mobility and polarization switching characteristics under an external field applied to the nonpolar face. Using band-excitation piezoresponse force microscopy, we demonstrate a selective switching-inhibition mechanism driven by the enhanced charge screening.

36 MATERIALS SCIENCE↗

Interpreting scattered neutron spectra on omega cryogenic implosions with measured backgrounds and higher-order scattering

Measurements of the areal density (⁠ρR⁠) of inertially confined implosions are critical to evaluate their performance. On OMEGA, ρR is inferred from measurements of the scattered neutron spectrum via neutron-time-of-flight (nTOF) and magnetic recoil spectrometer detectors. The nTOF measurements, in particular, have the ability to measure a wide range of neutron energies and thus scattering angles, with high precision. However, the neutrons that are backscattered into the detector must transit through the entire dense fuel assembly, and as a result are subject to rescattering effects, which have been heretofore neglected in the interpretation of OMEGA neutron spectra. At the backscatter edge, neglecting rescattering on OMEGA can lead to a ~10 to 20% reduction of the apparent areal density and therefore must be included in the analysis. The low ρR s on OMEGA also mean that backgrounds from non-target physics effects, such as scattering in the target chamber or slow scintillator decays, can significantly alter the measured signal. Here, we discuss how the Monte Carlo neutron spectrum postprocessor IRIS is used to include second-order scattering effects in the interpretation of the scattered neutron spectrum in OMEGA implosion experiments, and how dedicated implosion experiments are used to measure nTOF backgrounds in order to infer backscattered areal densities on OMEGA.

Deuterium↗

FLASH-therapy suitable single-pulse proton generation using TiH 2 under nanosecond laser irradiation

We investigated proton emission from titanium hydride (TiH 2 ) targets irradiated in vacuum by a 6-ns, 1064-nm Nd:YAG laser. Time-of-flight measurements with a Faraday cup and an electrostatic ion analyzer resolved distinct proton peaks at high pulse energies, with yields on the order of 10 9 protons per shot. Systematic scans over pulse energy and up to 1000 repeated shots showed that, while the peak amplitude gradually decreased, the integrated proton number remained nearly constant. This behavior is consistent with surface-induced broadening of the plasma expansion while bulk hydrogen is replenished by diffusion and repeated ablation of fresh TiH 2 layers. Using the measured proton numbers and pulse widths, a simple direct-plasma-injection-style scaling indicates peak currents of ∼100 mA and sub-microsecond pulse durations. The pulse structure and yield satisfy key ultra-high-dose-rate criteria and, together with sustained output over 1000 shots, support TiH 2 -based laser ion sources as practical candidates for FLASH-therapy (ultra-high-dose-rate)-oriented studies and injector development using direct plasma injection.

43 PARTICLE ACCELERATORS↗