Search NASA⌕ Search

SEARCH · Search NASA

Results for “trajectory data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Accelerating Dynamic Magnetic Resonance Imaging (MRI) for Lung Tumor Tracking Based on Low-Rank Decomposition in the Spatial–Temporal Domain: A Feasibility Study Based on Simulation and Preliminary Prospective Undersampled MRI

Purpose: To evaluate a low-rank decomposition method to reconstruct down-sampled k-space data for the purpose of tumor tracking. Methods and Materials: Seven retrospective lung cancer patients were included in the simulation study. The fully-sampled k-space data were first generated from existing 2-dimensional dynamic MR images and then down-sampled by 5 × -20 × before reconstruction using a Cartesian undersampling mask. Two methods, a low-rank decomposition method using combined dynamic MR images (k-t SLR based on sparsity and low-rank penalties) and a total variation (TV) method using individual dynamic MR frames, were used to reconstruct images. The tumor trajectories were derived on the basis of autosegmentation of the resultant images. To further test its feasibility, k-t SLR was used to reconstruct prospective data of a healthy subject. An undersampled balanced steady-state free precession sequence with the same undersampling mask was used to acquire the imaging data. Results: In the simulation study, higher imaging fidelity and low noise levels were achieved with the k-t SLR compared with TV. At 10 × undersampling, the k-t SLR method resulted in an average normalized mean square error <0.05, as opposed to 0.23 by using the TV reconstruction on individual frames. Less than 6% showed tracking errors >1 mm with 10 × down-sampling using k-t SLR, as opposed to 17% using TV. In the prospective study, k-t SLR substantially reduced reconstruction artifacts and retained anatomic details. Conclusions: Magnetic resonance reconstruction using k-t SLR on highly undersampled dynamic MR imaging data results in high image quality useful for tumor tracking. The k-t SLR was superior to TV by better exploiting the intrinsic anatomic coherence of the same patient. The feasibility of k-t SLR was demonstrated by prospective imaging acquisition and reconstruction.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Actinium–DOTA coordination in water from hybrid ML/MM: Structure, free energies, and water-exchange pathways

Quantitative simulation of trivalent ƒ-block chelates in water remains challenging because bonded and non-bonded force-field models make different approximations for coordination structure, exchange dynamics, and ion–ligand interactions in highly charged systems. Here, we develop a hybrid machine-learning/molecular-mechanics (ML/MM) framework for Ac 3+ –DOTA in explicit solvent by training an E(3)-equivariant neural network potential (MACELES) on mechanically embedded QM/MM data for Ac aquo and Ac–DOTA species and coupling it to NAMD 2.14 with particle-mesh Ewald electrostatics. Nanosecond ML/MM trajectories remain numerically stable and preserve chelate integrity, yielding a compact DOTA inner shell with an inner-sphere water coordination number of CN Ac,O w ≈ 1.7 arising from a dynamic equilibrium between one- and two-water states (37.5% and 59.9% of frames; three waters 2.5%). A 5 ns potential of mean force shows two low-lying basins at CN Ac,O w ≈ 1 and CN Ac,O w ≈ 2. DFT end-state free energies are consistent with the ML/MM profile, and DFT minimum-energy paths provide a qualitative electronic-structure reference for the observed basin connectivity. State-resolved kinetics reveal picosecond water-exchange pathways that couple hydration changes to transient DOTA arm fluctuations, and training-set comparisons show that temperature-matched Ac–DOTA data optimize energy/force accuracy while more diverse solvated data improve charge prediction. Overall, the present hybrid ML/MM model provides a practical description of Ac 3+ –DOTA hydration thermodynamics and short-time exchange behavior in explicit water at MD-like cost.

Actinium↗

Automated identification and calculation of prompt effects in kinetic mechanisms using statistical models

The kinetics of prompt dissociation involves rovibrationally excited species (generally formed by exothermic reactions) which may dissociate or isomerize prior to thermalization via collisions with the bath gas. Treating such rovibrationally excited species (so-called "hot" species) with standard kinetic phenomenology may result in incorrect macroscopic representation of their reactivity. Here this work presents the first fully automated methodology for the calculation of prompt effects of a chosen species in a kinetic mechanism, including (i) reaction selection; (ii) theoretical calculation of rate constants and prompt branching fractions; and (iii) final rate constant fitting. The energy partition between hot fragments is estimated using a variety of statistical models, including a new physically sound microcanonical statistical model based on the rovibrational density of states of the fragments. The methodology is validated against literature data for the prompt dissociations of HCO and C 3 H 7 radicals. The microcanonical statistical model is in better agreement with trajectory simulations for larger species and is thus applicable for practical systems that typically involve large molecules, for which direct dynamics calculations are impractical. The automated workflow is applied to the evaluation of the effects of prompt dissociation for two isomeric radicals C 4 H 7 1-3 (1-methylallyl) and C 4 H 7 1-4 (3-buten-1-yl). Twelve H-atom abstraction reactions are selected and the corresponding rate constants are computed with first principles theory. The microcanonical statistical model predicts that prompt dissociations of C 4 H 7 1-3 and C 4 H 7 1-4 are already significant at 1000K, resulting in differences of up to an order of magnitude at 2000K with respect to the phenomenological thermal rate constants. To illustrate the effects of prompt dissociation on simulations of experimental data, the calculated prompt rate constants are implemented in both CRECK and C3MechV3.3 kinetic mechanisms. Simulations of experimental flame data illustrate the noticeable impact of prompt dissociation kinetics on the high-temperature combustion reactivity of C 4 H 8 -1 and C 4 H 8 -2.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The influence of magmatic differentiation on the oxidation state of Fe in a basaltic arc magma

Subduction zone basalts are more oxidized than basalts from other tectonic settings (e.g., higher Fe{sup 3+}/{Sigma}Fe), and this contrast may play a central role in the unique geochemical processes that generate arc and continental crust. The processes generating oxidized arc magmas, however, are poorly constrained, although they appear inherently linked to subduction. Near-surface differentiation processes unique to arc settings might drive oxidation of magmas that originate in equilibrium with a relatively reduced mantle source. Alternatively, arc magmas could record the oxidation conditions of a relatively oxidized mantle source. Here, we present new measurements of olivine-hosted melt inclusions from a single eruption of Agrigan volcano, Marianas, in order to test the influence of differentiation processes vs. source conditions on the Fe{sup 3+}/{Sigma}Fe ratio, a proxy for system oxygen fugacity (fO{sub 2}). We determined Fe{sup 3+}/{Sigma}Fe ratios in glass inclusions using {mu}-XANES and couple these data with major elements, dissolved volatiles, and trace elements. After correcting for post-entrapment crystallization, Fe{sup 3+}/{Sigma}Fe ratios in the Agrigan melt inclusions (0.219 to 0.282), and their modeled fO{sub 2}s ({Delta}QFM + 1.0 to + 1.8), are uniformly more oxidized than MORB, and preserve a portion of the evolution of this magma from 5.7 to 3.2 wt.% MgO. Fractionation of olivine {+-} clinopyroxene {+-} plagioclase should increase Fe{sup 3+}/{Sigma}Fe as MgO decreases in the melt, but the data show Fe{sup 3+}/{Sigma}Fe ratios decreasing as MgO decreases below 5 wt.% MgO. The major element trajectories, taken in combination with this strong reduction trend, are inconsistent with crystallization of common ferromagnesian phases found in the bulk Agrigan sample, including magnetite. Rather, decreasing Fe{sup 3+}/{Sigma}Fe ratios correlate with decreasing S concentrations, suggesting that electronic exchanges associated with SO{sub 2} degassing may dominate Fe{sup 3+}/{Sigma}Fe variations in the melt during differentiation. In the case of this magma, the dominant effect of differentiation on magmatic fO{sub 2} is reduction rather than oxidation. Tracing back Agrigan melts with MgO > 5 wt.% (i.e., minimally degassed for S) along a modeled olivine fractionation trend to primary melts in equilibrium with Fo{sub 90} olivine reveals melts in equilibrium with the mantle beneath Agrigan at fO{sub 2}s of {Delta}QFM + 1 to + 1.6, significantly more oxidized than current constraints for the mantle beneath mid-ocean ridges.

58 GEOSCIENCES↗

The derivation of CRSS in pure Ti and Ti-Al alloys

The work focuses on the determination of the critical resolved shear stress (CRSS) in titanium (Ti) and titanium-aluminum (Ti-Al) alloys, influenced by an array of factors such as non-symmetric fault energies and minimum energy paths, dislocation core-widths, short-range order (SRO) effects which alter the local atomic environment, and tension-compression (T-C) asymmetry affected by intermittent slip motion. To address these multifaceted complexities, an advanced theory has been developed, offering an in-depth understanding of the mechanisms underlying slip behavior. The active slip systems in these materials are basal, prismatic, and pyramidal planes, with the latter involving both $\langle$a$\rangle$ and $\langle$c + a$\rangle$ dislocations. Each slip system is characterized by distinct Wigner-Seitz cell configurations for misfit energy calculations, varying partial dislocation separation distances, and unique dislocation trajectories—all critical to precise CRSS calculations. The theoretical CRSS results were validated against a comprehensive range of experimental data, demonstrating a strong agreement and underscoring the model's efficacy.

Critical stress↗

Electrostatic Matching of a High Current Proton Beam to a RFQ

In order to demonstrate the operation of a prototype DWA (dielectric wall accelerator), it was necessary to modify the LEBT of a commercially procured proton RFQ (Radio Frequency Quadrupole) injector linac. The relatively high output current (35 mA) of the duoplasmatron ion source at the low injection energy of 35 keV to the RFQ presented a matching problem in the beam transport due to the high space charge, the fixed transport length, and the small beam size required at the RFQ. In addition, only the use of electrostatic lenses was considered in order to minimize the size of the system. The standard AccSys design using one decel-accel einzel lens proved to be insufficient, so three new solutions were proposed, each using a pair of decelerating einzel lenses. The tool used to optimize these designs was a newly developed feature of the program IGUN. The RFQ acceptance ellipse is plotted on top of the phase space data of the transport calculation together with an ellipse with the same Twiss parameters which just encloses all the trajectories. The quality of matching is then given as the ratio of the areas of these two ellipses, making optimization easy. This paper will present the results of this optimization and the performance of the actual equipment built and tested.

43 PARTICLE ACCELERATORS↗

Stochastic simulation of electron avalanches on supercomputers

In the paper, we present a three-dimensional parallel Monte Carlo algorithm named ELSHOW which is developed for simulation of electron avalanches in gases. Parallel implementation of the ELSHOW was made on supercomputers with different architectures (massive parallel and hybrid ones). Using the ELSHOW, calculations of such integral characteristics as the number of particles in an avalanche, the coefficient of impact ionization, the drift velocity, and the others were made. Also, special precise computations were made to select an appropriate size of the time step using the technique of dependent statistical tests. Particularly, the algorithm consists of special methods of distribution modeling, a lexicographic implementation scheme for “branching” of trajectories, justified estimation of functionals. A comparison of the obtained results for nitrogen with previously published theoretical and experimental data was made.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Suitability of markerless EPID tracking for tumor position verification in gated radiotherapy

Purpose: To maximize the benefits of respiratory gated radiotherapy (RGRT) of lung tumors real-time verification of the tumor position is required. This work investigates the feasibility of markerless tracking of lung tumors during beam-on time in electronic portal imaging device (EPID) images of the MV therapeutic beam. Methods: EPID movies were acquired at ∼2 fps for seven lung cancer patients with tumor peak-to-peak motion ranges between 7.8 and 17.9 mm (mean: 13.7 mm) undergoing stereotactic body radiotherapy. The external breathing motion of the abdomen was synchronously measured. Both datasets were retrospectively analyzed inPortalTrack, an in-house developed tracking software. The authors define a three-step procedure to run the simulations: (1) gating window definition, (2) gated-beam delivery simulation, and (3) tumor tracking. First, an amplitude threshold level was set on the external signal, defining the onset of beam-on/-off signals. This information was then mapped onto a sequence of EPID images to generate stamps of beam-on/-hold periods throughout the EPID movies in PortalTrack, by obscuring the frames corresponding to beam-off times. Last, tumor motion in the superior-inferior direction was determined on portal images by the tracking algorithm during beam-on time. The residual motion inside the gating window as well as target coverage (TC) and the marginal target displacement (MTD) were used as measures to quantify tumor position variability. Results: Tumor position monitoring and estimation from beam's-eye-view images during RGRT was possible in 67% of the analyzed beams. For a reference gating window of 5 mm, deviations ranging from 2% to 86% (35% on average) were recorded between the reference and measured residual motion. TC (range: 62%–93%; mean: 77%) losses were correlated with false positives incidence rates resulting mostly from intra-/inter-beam baseline drifts, as well as sudden cycle-to-cycle fluctuations in exhale positions. Both phenomena can lead to considerable deviations (with MTD values up to a maximum of 7.8 mm) from the intended tumor position, and in turn may result in a marginal miss. The difference between tumor traces determined within the gating window against ground truth trajectory maps was 1.1 ± 0.7 mm on average (range: 0.4–2.3 mm). Conclusions: In this retrospective analysis of motion data, it is demonstrated that the system is capable of determining tumor positions in the plane perpendicular to the beam direction without the aid of fiducial markers, and may hence be suitable as an online verification tool in RGRT. It may be possible to use the tracking information to enable on-the-fly corrections to intra-/inter-beam variations by adapting the gating window by means of a robotic couch.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Acoustic Rocket Signatures Collected by Smartphones

Rockets generate complex acoustic signatures that can be detected over a thousand kilometers from their source. While many far-field acoustic rocket signatures have been collected and released to the public, very few signatures collected at distances less than 100 km are available. This work presents a curated and annotated dataset of acoustic signatures of 243 rocket launches collected by a network of smartphones stationed at distances between 10 and 70 km from the launch sites, resulting in 1089 individual recordings. Due to the frequency dependence of atmospheric attenuation and the relatively short propagation distances, higher-frequency features not preserved in most publicly available data are observed. The signals are time-aligned to allow for different segments of the signal (ignition, launch, trajectory, chronology) to be more easily examined and compared. Initial analysis of the features of these rocket launch stages is performed, observed features are compared to those found in the existing literature, and comparisons between signals from launches of different rocket types are made. The dataset is annotated and made available to the public to aid future analysis of the characteristics and source mechanisms of rocket acoustics as well as applications such as rocket detection and classification models.

33 ADVANCED PROPULSION SYSTEMS↗

A Novel Respiratory Motion Perturbation Model Adaptable to Patient Breathing Irregularities

Purpose: To develop a physical, adaptive motion perturbation model to predict tumor motion using feedback from dynamic measurement of breathing conditions to compensate for breathing irregularities. Methods and Materials: A novel respiratory motion perturbation (RMP) model was developed to predict tumor motion variations caused by breathing irregularities. This model contained 2 terms: the initial tumor motion trajectory, measured from 4-dimensional computed tomography (4DCT) images, and motion perturbation, calculated from breathing variations in tidal volume (TV) and breathing pattern (BP). The motion perturbation was derived from the patient-specific anatomy, tumor-specific location, and time-dependent breathing variations. Ten patients were studied, and 2 amplitude-binned 4DCT images for each patient were acquired within 2 weeks. The motion trajectories of 40 corresponding bifurcation points in both 4DCT images of each patient were obtained using deformable image registration. An in-house 4D data processing toolbox was developed to calculate the TV and BP as functions of the breathing phase. The motion was predicted from the simulation 4DCT scan to the treatment 4DCT scan, and vice versa, resulting in 800 predictions. For comparison, noncorrected motion differences and the predictions from a published 5-dimensional model were used. Results: The average motion range in the superoinferior direction was 9.4 ± 4.4 mm, the average ΔTV ranged from 10 to 248 mm{sup 3} (−26% to 61%), and the ΔBP ranged from 0 to 0.2 (−71% to 333%) between the 2 4DCT scans. The mean noncorrected motion difference was 2.0 ± 2.8 mm between 2 4DCT motion trajectories. After applying the RMP model, the mean motion difference was reduced significantly to 1.2 ± 1.8 mm (P=.0018), a 40% improvement, similar to the 1.2 ± 1.8 mm (P=.72) predicted with the 5-dimensional model. Conclusions: A novel physical RMP model was developed with an average accuracy of 1.2 ± 1.8 mm for interfraction motion prediction, similar to that of a published lung motion model. This physical RMP was analytically derived and is able to adapt to breathing irregularities. Further improvement of this RMP model is under investigation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

How Advances in Imaging Will Affect Precision Radiation Oncology

Radiation oncology is 1 of the most structured disciplines in medicine. It is of a highly technical nature with reliance on robotic systems to deliver intervention, engagement of diverse expertise, and early adoption of digital approaches to optimize and execute the application of this highly effective cancer treatment. As a localized intervention, the dependence on sensitive, specific, and accurate imaging to define the extent of disease, its heterogeneity, and adjacency to normal tissues directly affects the therapeutic ratio. Image-based in vivo temporal monitoring of the response to treatment enables adaptation and further affects the therapeutic ratio. Thus, more precise intervention will enable fractionation schedules that better interoperate with advances such as immunotherapy. In the data set–rich era that promises precision and personalized medicine, the radiation oncology field will integrate these new data into highly protocoled pathways of care that begin with multimodality prediction and enable patient-specific adaptation of therapy based on quantitative measures of the individual's dose–volume temporal trajectory and midtherapy predictions of response. In addition to advancements in computed tomography imaging, emerging technologies, such as ultra-high-field magnetic resonance and molecular imaging will bring new information to the design of treatments. Next-generation image guided radiation therapy systems will inject high specificity and sensitivity data and stimulate adaptive replanning. In addition, a myriad of pre- and peritherapeutic markers derived from advances in molecular pathology (eg, tumor genomics), automated and comprehensive imaging analytics (eg, radiomics, tumor microenvironment), and many other emerging biomarkers (eg, circulating tumor cell assays) will need to be integrated to maximize the benefit of radiation therapy for an individual patient. We present a perspective on the promise and challenges of fully exploiting imaging data in the pursuit of personalized radiation therapy, drawing from the presentations and broader discussions at the 2016 American Society of Therapeutic Radiation Oncology–National Cancer Institute workshop on Precision Medicine in Radiation Oncology (Bethesda, MD).

62 RADIOLOGY AND NUCLEAR MEDICINE↗

r-process abundances in neutron-rich merger ejecta given different theoretical nuclear physics inputs

This data release contains nucleosynthesis predictions for the r-process abundances presented in Côté, Eichler, Yagüe, Vassh et al. (2021) for compact object merger ejecta based on the publicly available simulation trajectories of Rosswog et al. (2013). All ejecta for the merger scenarios considered here are very neutron-rich (Ye ~ 0.016-0.11). Calculations were performed with the PRISM code (Mumpower et al. 2018) which accounts for nuclear reheating (here with a reheating efficiency of 50%). Results are reported for several different theoretical nuclear physics inputs but all calculations make use of the GEF fission yield prescription (see Vassh et al. 2019). All abundances are given at 1 Myr (10^6 years) post-merger. Please see the README file for more details and references. When using these nucleosynthesis yields, please cite this Zenodo data release (Vassh et al. 2021), and refer to Vassh et al. (2019) and Côté, Eichler, Yagüe, Vassh et al. (2021) for further details on the nuclear data applied as well as Rosswog et al. (2013), Piran et al. (2013), and Korobkin et al. (2012) for further details on the merger ejecta trajectories.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Four-Dimensional Patient Dose Reconstruction for Scanned Ion Beam Therapy of Moving Liver Tumors

Purpose: Estimation of the actual delivered 4-dimensional (4D) dose in treatments of patients with mobile hepatocellular cancer with scanned carbon ion beam therapy. Methods and Materials: Six patients were treated with 4 fractions to a total relative biological effectiveness (RBE)–weighted dose of 40 Gy (RBE) using a single field. Respiratory motion was addressed by dedicated margins and abdominal compression (5 patients) or gating (1 patient). 4D treatment dose reconstructions based on the treatment records and the measured motion monitoring data were performed for the single-fraction dose and a total of 17 fractions. To assess the impact of uncertainties in the temporal correlation between motion trajectory and beam delivery sequence, 3 dose distributions for varying temporal correlation were calculated per fraction. For 3 patients, the total treatment dose was formed from the fractional distributions using all possible combinations. Clinical target volume (CTV) coverage was analyzed using the volumes receiving at least 95% (V{sub 95}) and 107% (V{sub 107}) of the planned doses. Results: 4D dose reconstruction based on daily measured data is possible in a clinical setting. V{sub 95} and V{sub 107} values for the single fractions ranged between 72% and 100%, and 0% and 32%, respectively. The estimated total treatment dose to the CTV exhibited improved and more robust dose coverage (mean V{sub 95} > 87%, SD < 3%) and overdose (mean V{sub 107} < 4%, SD < 3%) with respect to the single-fraction dose for all analyzed patients. Conclusions: A considerable impact of interplay effects on the single-fraction CTV dose was found for most of the analyzed patients. However, due to the fractionated treatment, dose heterogeneities were substantially reduced for the total treatment dose. 4D treatment dose reconstruction for scanned ion beam therapy is technically feasible and may evolve into a valuable tool for dose assessment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Comparison of GEANT4 Simulations with Experimental Data for Thick Al Absorbers

Proton beams in medical applications deal with relatively thick targets like the human head or trunk. Therefore, relatively small differences in the total proton stopping power given, for example, by the different models provided by GEANT4 can lead to significant disagreements in the final proton energy spectra when integrated along lengthy proton trajectories. This work presents proton energy spectra obtained by GEANT4.8.2 simulations using ICRU49, Ziegler1985 and Ziegler2000 models for 19.68 MeV protons passing through a number of Al absorbers with various thicknesses. The spectra were compared with the experimental data, with TRIM/SRIM2008 and MCNPX2.4.0 simulations, and with the Payne analytical solution for the transport equation in the Fokker-Plank approximation. It is shown that the MCNPX simulations reasonably reproduce well all experimental spectra. For the relatively thin targets all the methods give practically identical results but this is not the same for the thick absorbers. It should be noted that all the spectra were measured at the proton energies significantly above 2 MeV, i.e., in the so-called 'Bethe-Bloch region'. Therefore the observed disagreements in GEANT4 results, simulated with different models, are somewhat unexpected. Further studies are necessary for better understanding and definitive conclusions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Four dimensional magnetic resonance imaging with retrospective k-space reordering: A feasibility study

Purpose: Current four dimensional magnetic resonance imaging (4D-MRI) techniques lack sufficient temporal/spatial resolution and consistent tumor contrast. To overcome these limitations, this study presents the development and initial evaluation of a new strategy for 4D-MRI which is based on retrospective k-space reordering. Methods: We simulated a k-space reordered 4D-MRI on a 4D digital extended cardiac-torso (XCAT) human phantom. A 2D echo planar imaging MRI sequence [frame rate (F) = 0.448 Hz; image resolution (R) = 256 × 256; number of k-space segments (N{sub KS}) = 4] with sequential image acquisition mode was assumed for the simulation. Image quality of the simulated “4D-MRI” acquired from the XCAT phantom was qualitatively evaluated, and tumor motion trajectories were compared to input signals. In particular, mean absolute amplitude differences (D) and cross correlation coefficients (CC) were calculated. Furthermore, to evaluate the data sufficient condition for the new 4D-MRI technique, a comprehensive simulation study was performed using 30 cancer patients’ respiratory profiles to study the relationships between data completeness (C{sub p}) and a number of impacting factors: the number of repeated scans (N{sub R}), number of slices (N{sub S}), number of respiratory phase bins (N{sub P}), N{sub KS}, F, R, and initial respiratory phase at image acquisition (P{sub 0}). As a proof-of-concept, we implemented the proposed k-space reordering 4D-MRI technique on a T2-weighted fast spin echo MR sequence and tested it on a healthy volunteer. Results: The simulated 4D-MRI acquired from the XCAT phantom matched closely to the original XCAT images. Tumor motion trajectories measured from the simulated 4D-MRI matched well with input signals (D = 0.83 and 0.83 mm, and CC = 0.998 and 0.992 in superior–inferior and anterior–posterior directions, respectively). The relationship between C{sub p} and N{sub R} was found best represented by an exponential function (C{sub P}=100(1−e{sup −0.18N{sub R}}), when N{sub S} = 30, N{sub P} = 6). At a C{sub P} value of 95%, the relative error in tumor volume was 0.66%, indicating that N{sub R} at a C{sub P} value of 95% (N{sub R,95%}) is sufficient. It was found that N{sub R,95%} is approximately linearly proportional to N{sub P} (r = 0.99), and nearly independent of all other factors. The 4D-MRI images of the healthy volunteer clearly demonstrated respiratory motion in the diaphragm region with minimal motion induced noise or aliasing. Conclusions: It is feasible to generate respiratory correlated 4D-MRI by retrospectively reordering k-space based on respiratory phase. This new technology may lead to the next generation 4D-MRI with high spatiotemporal resolution and optimal tumor contrast, holding great promises to improve the motion management in radiotherapy of mobile cancers.

60 APPLIED LIFE SCIENCES↗

Continuous-scanning laser Doppler vibrometry: Extensions to arbitrary areas, multi-frequency and 3D capture

To date, differing implementations of continuous scan laser Doppler vibrometry have been demonstrated by various academic institutions, but since the scan paths were defined using step or sine functions from function generators, the paths were typically limited to 1D line scans or 2D areas such as raster paths or Lissajous trajectories. The excitation was previously often limited to a single frequency due to the specific signal processing performed to convert the scan data into an ODS. In this paper, a configuration of continuous-scan laser Doppler vibrometry is demonstrated which permits scanning of arbitrary areas, with the benefit of allowing multi-frequency/broadband excitation. Various means of generating scan paths to inspect arbitrary areas are discussed and demonstrated. Further, full 3D vibration capture is demonstrated by the addition of a range-finding facility to the described configuration, and iteratively relocating a single scanning laser head. Here, the range-finding facility was provided by a Microsoft Kinect, an inexpensive piece of consumer electronics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Inferring demographic and selective histories from population genomic data using a 2-step approach in species with coding-sparse genomes: an application to human data

Abstract The demographic history of a population, and the distribution of fitness effects (DFE) of newly arising mutations in functional genomic regions, are fundamental factors dictating both genetic variation and evolutionary trajectories. Although both demographic and DFE inference has been performed extensively in humans, these approaches have generally either been limited to simple demographic models involving a single population, or, where a complex population history has been inferred, without accounting for the potentially confounding effects of selection at linked sites. Taking advantage of the coding-sparse nature of the genome, we propose a 2-step approach in which coalescent simulations are first used to infer a complex multi-population demographic model, utilizing large non-functional regions that are likely free from the effects of background selection. We then use forward-in-time simulations to perform DFE inference in functional regions, conditional on the complex demography inferred and utilizing expected background selection effects in the estimation procedure. Throughout, recombination and mutation rate maps were used to account for the underlying empirical rate heterogeneity across the human genome. Importantly, within this framework it is possible to utilize and fit multiple aspects of the data, and this inference scheme represents a generalized approach for such large-scale inference in species with coding-sparse genomes.

Soni, Vivak (ORCID:0000000294969562)↗

Liver motion during cone beam computed tomography guided stereotactic body radiation therapy

Purpose: Understanding motion characteristics of liver such as, interfractional and intrafractional motion variability, difference in motion within different locations in the organ, and their complex relationship with the breathing cycles are particularly important for image-guided liver SBRT. The purpose of this study was to investigate such motion characteristics based on fiducial markers tracked with the x-ray projections of the CBCT scans, taken immediately prior to the treatments. Methods: Twenty liver SBRT patients were analyzed. Each patient had three fiducial markers (2 Multiplication-Sign 5-mm gold) percutaneously implanted around the gross tumor. The prescription ranged from 2 to 8 fractions per patient. The CBCT projections data for each fraction ({approx}650 projections/scan), for each patient, were analyzed and the 2D positions of the markers were extracted using an in-house algorithm. In total, >55 000 x-ray projections were analyzed from 85 CBCT scans. From the 2D extracted positions, a 3D motion trajectory of the markers was constructed, from each CBCT scans, resulting in left-right (LR), anterior-posterior (AP), and cranio-caudal (CC) location information of the markers with >55 000 data points. The authors then analyzed the interfraction and intrafraction liver motion variability, within different locations in the organ, and as a function of the breathing cycle. The authors also compared the motion characteristics against the planning 4DCT and the RPM Trade-Mark-Sign (Varian Medical Systems, Palo Alto, CA) breathing traces. Variations in the appropriate gating window (defined as the percent of the maximum range at which 50% of the marker positions are contained), between fractions were calculated as well. Results: The range of motion for the 20 patients were 3.0 {+-} 2.0 mm, 5.1 {+-} 3.1 mm, and 17.9 {+-} 5.1 mm in the planning 4DCT, and 2.8 {+-} 1.6 mm, 5.3 {+-} 3.1 mm, and 16.5 {+-} 5.7 mm in the treatment CBCT, for LR, AP, and CC directions, respectively. The range of respiratory period was 3.9 {+-} 0.7 and 4.2 {+-} 0.8 s during the 4DCT simulation and the CBCT scans, respectively. The authors found that breathing-induced AP and CC motions are highly correlated. That is, all markers moved cranially also moved posteriorly and vice versa, irrespective of the location. The LR motion had a more variable relationship with the AP/CC motions, and appeared random with respect to the location. That is, when the markers moved toward cranial-posterior direction, 58% of the markers moved to the patient-right, 22% of the markers moved to the patient-left, and 20% of the markers had minimal/none motion. The absolute difference in the motion magnitude between the markers, in different locations within the liver, had a positive correlation with the absolute distance between the markers (R{sup 2}= 0.69, linear-fit). The interfractional gating window varied significantly for some patients, with the largest having 29.4%-56.4% range between fractions. Conclusions: This study analyzed the liver motion characteristics of 20 patients undergoing SBRT. A large variation in motion was observed, interfractionally and intrafractionally, and that as the distance between the markers increased, the difference in the absolute range of motion also increased. This suggests that marker(s) in closest proximity to the target be used.

60 APPLIED LIFE SCIENCES↗