Search NASA⌕ Search

SEARCH · Search NASA

Results for “trapped”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Trapped-ion Quantum Network Real-time Control Software (QuantNet Real-time Control) v0.1.0

This real-time control software for the QUANT-NET testbed is built upon the ARTIQ (Advanced Real-Time Infrastructure for Quantum physics) ecosystem. A central contribution of this work is the software's modular and reusable architecture, which facilitates the creation of hierarchical experimental control sequences by combining precomposed sequences and subsequences as building blocks within the framework.

Cheah, You-Wei [Lawrence Berkeley National Laborat↗

Ambient Ion Trapping and Separations for High Throughput Structurally Selective Material Deposition

While ion mobility coupled to mass spectrometry (IMS/MS) has been increasingly adapted to biological analysis, the structural and molecular specificity offered by IMS/MS has untapped potential for creating novel materials (for energy, catalysis, biomolecular switches etc.) with rationally tailored properties by precisely controlling the chemical structure and composition of these materials. While electrochemical and catalytic properties of the bulk material are understood by mass-selective ion-soft-landing, different structures of one molecule can exhibit distinct properties from the bulk. Many biological phenomenon occur at interfaces and are highly structurally specific. IMS/MS offers means to separate molecules in a sample (which is first ionized and released to gas phase from the condensed phase) based on mass and structure. Species thus separated can potentially be deposited onto surfaces with molecular and structural specificity, to perform fundamental investigations for understanding critical interfacial phenomenon. Key performance metrics for IMS/MS analysis are resolution of separations and sensitivity. Recently developed Structures for Lossless Ion Manipulations (SLIM)4 enabled unprecedented resolution in IMS separations. In addition, high sensitivity was enabled in SLIM due to lossless confinement of ions using radio frequency fields. Thus, SLIM enabled extremely long path length separations (up to 0.1 km thus far) providing efficient separation of molecular ions never before achieved (e.g. isotopologues, D&L amino acids). While SLIM has unprecedented analytical separations power/utility, the use of SLIM platform for depositing mobility and mass selected molecular ions has two specific technological challenges: (a) Pulsed nature of IMS separations and their low duty cycle and (b) the need for a low vacuum of ~4 torr for lossless ion confinement. These limitations lead to long deposition times due to loss of ions generated from the sample. Enabling ion confinement at atmospheric pressure will be path-breaking contribution to the fundamental understanding of ion manipulations and separations and will also enable novel science currently precluded due to the inability of the present technologies to confine ions under ambient conditions. Traditionally used radio frequency fields are ineffective in confining ions at high pressures due to ion/neutral collisions. To address these, we propose to (a) develop methods for confining and manipulating ions for lossless IMS separations at atmospheric pressure enabling high sensitivity and throughput and (b) use the high specificity of IMS/MS and high throughput from ambient ion confinement to perform mobility and mass selective ion deposition at atmospheric pressure. Our goal is to enable the study of the fundamental properties of energy/catalysis materials and biomolecules. This project paves the way for high-throughput, mass and structure selective material deposition for highly specific surface creation/functionalization (discussed in Section 2 of the report). Further, the developments reported continue to push the boundaries of this process to ambient conditions (discussed in Section 3 of the report). We conclude with a list of specific intellectual property and publications which have been the outcome of this funded project.

36 MATERIALS SCIENCE↗

Development of Passive HC/NOx Trap Catalysts for Low Temperature Gasoline Applications

This project aimed to develop fundamental understanding of the chemistry of NO adsorption and reaction in Pd/zeolites so as to facilitate the rational design of passive NOx adsorber catalysts. The approach adopted combined both experimental and computational methods, which together allow a deeper understanding of the governing chemistry than the use of either method alone. The workflow began with Pd/H-CHA and Pd/H-BEA catalyst synthesis and characterization, in which the Si/Al ratio and Al siting were systematically varied. This was followed by catalyst evaluation using temperature-programed adsorption/desorption methods, as well as in situ spectroscopic measurements to probe the chemistry of NO adsorption. In parallel, the adsorption of NO and other relevant species (H 2 O, CO, HCs) was studied by means of quantum chemical calculations in order to rationalize the experimental data and provide additional insights. Catalyst aging studies were also performed with the aim of elucidating the mechanism of catalyst degradation. Finally, the insights gained in this project were applied to the preparation of an optimized HC/NOx adsorber catalyst, the performance of which was studied using exhaust gas from an engine dynamometer.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Study of charge trapping in CZT detectors

A semiconductor detection material, Cadmium Zinc Telluride, was investigated for potential use as a particle detector for space flight applications. Our set of detectors was determined to be flawed for particle detection methods, likely due to charge transport mechanisms within the detector material, or due to reduced voltage required to avoid dielectric breakdown. It was observed that the method of crystal growth may play a role in the performance, but performance may also vary between manufacturers using the same growth method. It is recommended to perform further study at a larger proton beam facility.

47 OTHER INSTRUMENTATION↗