Search NASA⌕ Search

SEARCH · Search NASA

Results for “variability analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Mesoscale Variability in SUCCESS Data

Analysis of meteorological, chemical, and microphysical data from the airborne SUCCESS mission is reported. Careful analysis of the complex DC-8 flight pattern of May 2, 1996 reveals 19 linear or nearly linear flight segments within six main geographical areas, which we have analyzed. Significant mountain wave activity is revealed in the data from the MMS and MTP instruments on the DC-8, which resembles previous observations of mountain wave structures near Boulder, CO. Strong mountain-wave-induced upwelling downwind of the Rockies is noted. Turbulence is also noted in regions of the mountain wave consistent with overturning near the tropopause. Zonal winds recorded on the ER-2 are shown to consistent with mountain wave breaking at or near critical levels in the stratosphere, consistent with the strong turbulence reported by the pilot during the ER-2 flight. Those observations have been supported with spectral analyses and modeling studies. "Postcasts" of mountain wave activity on May 2, 1996, using the Naval Research Laboratory Mountain Wave Forecast Model (NRL/MWFM) predicts both strong mountain wave activity near the tropopause (as measured by the DC-8) and strong mountain-wave-induced turbulence in the stratosphere (as encountered by the ER-2). Two-dimensional simulations of fluid flow over topography reveal similar isentropic structures to observations.

Eckermann, Stephen D.↗

Mesoscale Variability in SUCCESS Data

Analysis of meteorological, chemical and microphysical data from the airborne SUCCESS (SUbsonic aircraft Contrail and Cloud Effects Special Study) mission is reported. Careful analysis of the complex DC-8 flight pattern of May 2, 1996 reveals 19 linear flight segments within six main geographical areas, which we have analyzed. Significant mountain wave activity is revealed in the data from the MMS (Meteorology Measurement System) and MTP (Microwave Temperature Profiler) instruments on the DC-8, which resembles previous observations of mountain wave structures near Boulder, Colorado. Strong mountain-wave-induced upwelling downwind of the Rockies is noted. Turbulence is also noted in regions of the mountain wave consistent with overturning near the tropopause. Zonal winds recorded on the ER-2 are shown to be consistent with mountain wave breaking at or near critical levels in the stratosphere, consistent with the strong turbulence reported by the pilot during the ER-2 flight. These observations have been supported with spectral analyses and modeling studies. 'Postcasts' of mountain wave activity on May 2, 1996 using the Naval Research Laboratory Mountain Wave Forecast Model predicts both strong mountain wave activity near the tropopause and strong mountain-wave-induced turbulence in the stratosphere.

Eckermann, Stephen D.↗

Model Analysis of the Factors Regulating Trends and Variability of Methane, Carbon Monoxide and OH: 1. Model Validation

Methane (CH4) is the second most important anthropogenic greenhouse gas (GHG). Its 100-year global warming potential (GWP) is 25 times larger than that for carbon dioxide. The 100-yr integrated GWP of CH4 is sensitive to changes in OH levels. Methane's atmospheric growth rate was estimated to be more than 10 ppb yr(exp -1) in 1998 but less than zero in 2001, 2004 and 2005 (Kirschke et al., 2013). Since 2006, the CH4 is increasing again. This phenomena is yet not well understood. Oxidation of CH4 by OH is the main loss process, thus affecting the oxidizing capacity of the atmosphere and contributing to the global ozone background. Current models typically use an annual cycle of offline OH fields to simulate CH4. The implemented OH fields in these models are typically tuned so that simulated CH4 growth rates match that measured. For future and climate simulations, the OH tuning technique may not be suitable. In addition, running full chemistry, multi-decadal CH4 simulations is a serious challenge and currently, due to computational intensity, almost impossible.

OH↗

Analysis of Correlation between Cold Weather Meteorological Variables and Electricity Outages

The significance of the impact of weather on the electric grid has grown as climate change continues to increase the frequency and intensity of extreme weather events. In recent years (2021-2022) in particular, extreme winter weather has affected the grid in locations in the US rarely exposed to extreme low temperatures, snow and icing conditions. Here we analyze the correlation between cold weather meteorological variables and electricity outages during two large winter storm events, Uri (February 2021) and Landon (February 2022) using Random Forest machine learning and Pearson’s correlation coefficient. Our geographical focus across the two storms is the state of Texas. Extrapolation of the method to winter weather impacts over other years and additional locations is proposed.

Dumas, Melissa↗

PULSE-PHASE-RESOLVED SPECTROSCOPY OF VELA X-1 WITH SUZAKU

We present a detailed pulse-phase-resolved spectral analysis of the persistent high-mass X-ray binary pulsar Vela X-1 observed with Suzaku during 2008 June. The pulse profiles exhibit both intensity and energy dependence with multiple peaks at low energies and double peaks at higher energies. The source shows some spectral evolution over the duration of the observation and care has been taken to average over data with minimum spectral variability for the analysis. We model the continuum with a phenomenological partial covering high-energy cutoff model and a more physical partial covering thermal Comptonization model (CompTT) excluding the time ranges having variable hardness ratio and intensity dependence. For both the models, we detect a cyclotron resonant scattering feature (CRSF) and its harmonic at {approx}25 keV and {approx}50 keV. Both the CRSF fundamental and harmonics parameters are strongly variable over the pulse phase, with the ratio of the two line energies deviating from the classical value of 2. The continuum parameters also show significant variation over the pulse phase and give us some idea about the changing physical conditions that are seen with the changing viewing angle at different pulse phases and obscuration by the accretion stream at some pulse phases.

79 ASTRONOMY AND ASTROPHYSICS↗

NASTRAN variance analysis and plotting of HBDY elements

The NASTRAN Thermal Analyzer has been intended to do variance analysis and plot the thermal boundary elements. The objective of the variance analysis addition is to assess the sensitivity of temperature variances resulting from uncertainties inherent in input parameters for heat conduction analysis. The plotting capability provides the ability to check the geometry (location, size and orientation) of the boundary elements of a model in relation to the conduction elements. Variance analysis is the study of uncertainties of the computed results as a function of uncertainties of the input data. To study this problem using NASTRAN, a solution is made for both the expected values of all inputs, plus another solution for each uncertain variable. A variance analysis module subtracts the results to form derivatives, and then can determine the expected deviations of output quantities.

Harder, R. L.↗

Colorado Front Range Disasters: Understanding the Impact of Forest Management on the Cameron Peak and CalWood Fire

Along the Colorado Front Range, forest management has gained significant attention due to uncharacteristically large fires that burned late in 2020. The Cameron Peak Fire (largest in Colorado recorded history) and the CalWood Fire collectively burned an estimated 219,019 acres from August through December of 2020. Project partners at the Coalition for the Poudre River Watershed, Colorado State Forest Service, Ben Delatour Scout Ranch, The Nature Conservancy, Colorado Forest Restoration Institute, and Colorado State University were interested in understanding the effectiveness of previous forest treatments in reducing burn severity within the Cameron Peak Fire and the CalWood Fire. We first collated a forest treatment dataset from pre-existing datasets by reclassifying over 29,000 treatments, which occurred across the Northern Colorado Front Range between 1970-2020. Secondly, we mapped three burn severity indices using Landsat 8 OLI and Sentinel-2 MSI Earth observations and compared them to soil burn severity field data. Thirdly, a total of 35 topographic, disturbance, forest structure, and treatment predictor variables were generated across the fires. Finally, we assessed relationships between these predictor variables and burn severity using the random forest algorithm. Model results indicate that the primary drivers of burn severity were elevation and distance to treatment edge for the Cameron Peak Fire and fire area and forest canopy cover for the CalWood Fire. Further analysis of these variables paired with field data is necessary to understand the relationship between burn severity and treatments to guide future restoration efforts, improve forest resiliency, and mitigate fire risks.

Neal Swayze↗

Probabilistic structural analysis computer code (NESSUS)

Probabilistic structural analysis has been developed to analyze the effects of fluctuating loads, variable material properties, and uncertain analytical models especially for high performance structures such as SSME turbopump blades. The computer code NESSUS (Numerical Evaluation of Stochastic Structure Under Stress) was developed to serve as a primary computation tool for the characterization of the probabilistic structural response due to the stochastic environments by statistical description. The code consists of three major modules NESSUS/PRE, NESSUS/FEM, and NESSUS/FPI. NESSUS/PRE is a preprocessor which decomposes the spatially correlated random variables into a set of uncorrelated random variables using a modal analysis method. NESSUS/FEM is a finite element module which provides structural sensitivities to all the random variables considered. NESSUS/FPI is Fast Probability Integration method by which a cumulative distribution function or a probability density function is calculated.

Shiao, Michael C.↗

Evaluation of global teleconnections in CMIP6 climate projections using complex networks

In climatological research, the evaluation of climate models is one of the central research subjects. As an expression of large-scale dynamical processes, global teleconnections play a major role in interannual to decadal climate variability. Their realistic representation is an indispensable requirement for the simulation of climate change, both natural and anthropogenic. Therefore, the evaluation of global teleconnections is of utmost importance when assessing the physical plausibility of climate projections. We present an application of the graph-theoretical analysis tool δ-MAPS, which constructs complex networks on the basis of spatio-temporal gridded data sets, here sea surface temperature and geopotential height at 500 hPa. Complex networks complement more traditional methods in the analysis of climate variability, like the classification of circulation regimes or empirical orthogonal functions, assuming a new non-linear perspective. While doing so, a number of technical tools and metrics, borrowed from different fields of data science, are implemented into the δ-MAPS framework in order to overcome specific challenges posed by our target problem. Those are trend empirical orthogonal functions (EOFs), distance correlation and distance multicorrelation, and the structural similarity index. δ-MAPS is a two-stage algorithm. In the first place, it assembles grid cells with highly coherent temporal evolution into so-called domains. In a second step, the teleconnections between the domains are inferred by means of the non-linear distance correlation. We construct 2 unipartite and 1 bipartite network for 22 historical CMIP6 climate projections and 2 century-long coupled reanalyses (CERA-20C and 20CRv3). Potential non-stationarity is taken into account by the use of moving time windows. The networks derived from projection data are compared to those from reanalyses. Our results indicate that no single climate projection outperforms all others in every aspect of the evaluation. But there are indeed models which tend to perform better/worse in many aspects. Differences in model performance are generally low within the geopotential height unipartite networks but higher in sea surface temperature and most pronounced in the bipartite network representing the interaction between ocean and atmosphere.

58 GEOSCIENCES↗

Dynamic Power Spectral Analysis of Solar Measurements from Photospheric, Chromospheric, and Coronal Sources

An important aspect in the power spectral analysis of solar variability is the quasistationary and quasiperiodic nature of solar periodicities. In other words, the frequency, phase, and amplitude of solar periodicities vary on time scales ranging from active region lifetimes to solar cycle time scales. Here, researchers employ a dynamic, or running, power spectral density analysis to determine many periodicities and their time-varying nature in the projected area of active sunspot groups (S sub act). The Solar Maximum Mission/Active Cavity Radiometer Irradiance Monitor (SMM/ACRIM) total solar irradiance (S), the Nimbus-7 MgII center-to-wing ratio (R (MgII sub c/w)), the Ottawa 10.7 cm flux (F sub 10.7), and the GOES background x ray flux (X sub b) for the maximum, descending, and minimum portions of solar cycle 21 (i.e., 1980 to 1986) are used. The technique dramatically illustrates several previously unrecognized periodicities. For example, a relatively stable period at about 51 days has been found in those indices which are related to emerging magnetic fields. The majority of solar periodicities, particularly around 27, 150 and 300 days, are quasiperiodic because they vary in amplitude and frequency throughout the solar cycle. Finally, it is shown that there are clear differences between the power spectral densities of solar measurements from photospheric, chromospheric, and coronal sources.

Bouwer, S. D.↗

Polarization Angle Swings in Blazars Detected in the Millimeter-wave with the South Pole Telescope

We present the first systematic search for electric vector position angle (EVPA) swings in the millimeter-wave (mm-wave) emission of blazars, using five years of observations from the South Pole Telescope SPT-3G camera at 95 and 150 GHz, and investigate their connection to gamma-ray flares. Of the 168 bright sources in the ~1500 square degrees SPT-3G Main Field, eight have sufficient polarization signal-to-noise for reliable EVPA measurement, four of which have continuous Fermi LAT gamma-ray detections. We detect EVPA swings in all four gamma-ray-active blazars and in none of the remaining four, consistent with the established connection between EVPA swings and high-energy emission seen at optical wavelengths. The observed swing amplitudes and rotation rates are smaller than those found in optical studies, consistent with mm-wave EVPA variability being slower than at shorter wavelengths. Random walk simulations of the polarization angle using a multi-cell model fail to reproduce both the number, amplitude, and duration of the observed swings, suggesting that this mechanism is insufficient to explain the observed swing population. Analysis of EVPA variability on one-week timescales is consistent with the anti-correlation between polarization degree and EVPA rotation rate previously observed at optical wavelengths. Of the 14 detected swings, eight are within 30 days of a gamma-ray flare. While many individual swing-flare associations are found to have a very low probability of happening by chance, the full ensembles of 95 and 150 GHz swing time lags with respect to gamma-ray flares are found to be consistent with random coincidence.

Simpson, A. [Chicago U., Astron. Astrophys. Ctr.; ↗

Lifestyle Factors in U.S. Residential Electricity Consumption

A multivariate statistical approach to lifestyle analysis of residential electricity consumption is described and illustrated. Factor analysis of selected variables from the 2005 U.S. Residential Energy Consumption Survey (RECS) identified five lifestyle factors reflecting social and behavioral choices associated with air conditioning, laundry usage, personal computer usage, climate zone of residence, and TV use. These factors were also estimated for 2001 RECS data. Multiple regression analysis using the lifestyle factors yields solutions accounting for approximately 40% of the variance in electricity consumption for both years. By adding the associated household and market characteristics of income, local electricity price and access to natural gas, variance accounted for is increased to approximately 54%. Income contributed only {approx}1% unique variance to the 2005 and 2001 models, indicating that lifestyle factors reflecting social and behavioral choices better account for consumption differences than income. This was not surprising given the 4-fold range of energy use at differing income levels. Geographic segmentation of factor scores is illustrated, and shows distinct clusters of consumption and lifestyle factors, particularly in suburban locations. The implications for tailored policy and planning interventions are discussed in relation to lifestyle issues.

03 NATURAL GAS↗

Advanced supersonic propulsion study, phases 3 and 4

An evaluation of various advanced propulsion concepts for supersonic cruise aircraft resulted in the identification of the double-bypass variable cycle engine as the most promising concept. This engine design utilizes special variable geometry components and an annular exhaust nozzle to provide high take-off thrust and low jet noise. The engine also provides good performance at both supersonic cruise and subsonic cruise. Emission characteristics are excellent. The advanced technology double-bypass variable cycle engine offers an improvement in aircraft range performance relative to earlier supersonic jet engine designs and yet at a lower level of engine noise. Research and technology programs required in certain design areas for this engine concept to realize its potential benefits include refined parametric analysis of selected variable cycle engines, screening of additional unconventional concepts, and engine preliminary design studies. Required critical technology programs are summarized.

Allan, R. D.↗

Materials properties numerical database system established and operational at CINDAS/Purdue University

A computerized comprehensive numerical database system on the mechanical, thermophysical, electronic, electrical, magnetic, optical, and other properties of various types of technologically important materials such as metals, alloys, composites, dielectrics, polymers, and ceramics has been established and operational at the Center for Information and Numerical Data Analysis and Synthesis (CINDAS) of Purdue University. This is an on-line, interactive, menu-driven, user-friendly database system. Users can easily search, retrieve, and manipulate the data from the database system without learning special query language, special commands, standardized names of materials, properties, variables, etc. It enables both the direct mode of search/retrieval of data for specified materials, properties, independent variables, etc., and the inverted mode of search/retrieval of candidate materials that meet a set of specified requirements (which is the computer-aided materials selection). It enables also tabular and graphical displays and on-line data manipulations such as units conversion, variables transformation, statistical analysis, etc., of the retrieved data. The development, content, accessibility, etc., of the database system are presented and discussed.

Ho, C. Y.↗

Performance of Variable Capacity Heat Pumps in a Mixed Humid Climate

Variable capacity heat pumps represent the next wave of technology for heat pumps. In this report, the performance of two variable capacity heat pumps (HPs) is compared to that of a single or two stage baseline system. The units were installed in two existing research houses located in Knoxville, TN. These houses were instrumented to collect energy use and temperature data while both the baseline systems and variable capacity systems were installed. The homes had computer controlled simulated occupancy, which provided consistent schedules for hot water use and lighting. The temperature control and energy use of the systems were compared during both the heating and cooling seasons. Multiple linear regression models were used along with TMY3 data for Knoxville, TN in order to normalize the effect that the outdoor air temperature has on energy use. This enables a prediction of each system's energy use over a year with the same weather. The first system was a multi-split system consisting of 8 indoor units and a single outdoor unit. This system replaced a 16 SEER single stage HP with a zoning system, which served as the baseline. Data was collected on the baseline system from August 2009 to December 2010 and on the multi-split system from January 2011 to January 2012. Soon after the installation of the multi-split system, some of the smaller rooms began over-conditioning. This was determined to be caused by a small amount of continuous refrigerant flow to all of the indoor units when the outdoor unit was running regardless of whether they were calling for heat. This, coupled with the fact that the indoor fans run continuously, was providing enough heat in some rooms to exceed the set point. In order to address this, the indoor fans were disabled when not actively heating per the manufacturer's recommendation. Based on the measured data, the multi-split system was predicted to use 40% more energy in the heating season and 16% more energy in the cooling season than the baseline system, for the typical meteorological year weather data. The AHRI ratings indicated that the baseline system would perform slightly better than the multi-split system, but not by as large of a margin as seen in this study. The multi-split system was able to maintain more consistent temperature throughout the house than the baseline system, but it did allow relative humidity levels to increase above 60% in the summer. The second system was a split system with an inverter driven compressor and a single ducted air handler. This unit replaced a 16 SEER two stage HP with a zoning system. Data was collected on the baseline system from July 2009 to November 2010 and on the ducted inverter system from December 2010 to January 2012. The ducted inverter system did not offer a zone controller, so it functioned as a single zone system. Due to this fact, the registers had to be manually adjusted in order to better maintain consistent temperatures between the two levels of the house. The predicted heating season energy use for the ducted inverter system, based on the measured energy use, was 30% less than that of the baseline system for the typical meteorological year. However, the baseline system was unable to operate in its high stage due to a wiring issue with the zone controller. This resulted in additional resistance heat use during the winter and therefore higher energy use than would be expected in a properly performing unit. The AHRI ratings would indicate that the baseline system would use less energy than the ducted inverter system, which is opposite to the results of this study. During the cooling season, the ducted inverter system was predicted to use 23% more energy than the baseline system during the typical meteorological year. This is also opposite of the results expected by comparing the AHRI ratings. After a detailed comparison of the ducted inverter system's power use compared to that of a recently installed identical system at a retro-fit study house, there is concern that the unit is not operating as intended. The power use and cycles indicate that the unit is performing more like a single stage unit than a variable capacity unit. Analysis of the data indicates that a change in operating behavior occurred during a service call shortly after the installation of the unit. The logbook only indicates that refrigerant charge was added, but does not indicate any other change. This is being investigated further. While the energy comparison results of these two variable capacity heat pumps is generally underwhelming, it is difficult to draw any hard conclusions about the maximum attainable efficiency of these units when optimally installed. Both units appear to have undesirable conditions associated with the installation or operation, which could have had an adverse effect on their energy use.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗