Search NASA⌕ Search

SEARCH · Search NASA

Results for “variability study”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Enhanced Boundary Layer Height Detection Using Ceilometer, Surface Meteorology, and Radiation Products With a Random Forest Ensemble Method

This study develops and evaluates a Random Forest (RF) model for estimating planetary boundary layer height (PBLH) using 9 years of data from the Atmospheric Radiation Measurement Southern Great Plains (ARM SGP) user facility, with potential application in the NOAA Surface Radiation (SURFRAD) Network. The model integrates ceilometer, surface meteorology, and radiation measurements, and is trained using thermodynamic PBLH estimates derived from radiosondes. This approach aims to bridge gaps between aerosol-based and thermodynamic-based PBLH estimates. The RF model outperformed traditional methods during daytime and better captured transition periods, demonstrating improved accuracy and robustness. At ARM SGP, it showed a substantial reduction in both bias and RMSE, with a bias near zero (−4.9 m) compared with traditional Haar Wavelet (HW) (70.9 m) and Vaisala BL-View software (124.1 m), and an RMSE of 303.2 m, lower than both BL-View (566.9 m) and HW (404.6 m). During daytime hours, RF consistently outperformed both alternatives, maintaining lower bias and RMSE across all periods. At a second evaluation site, RF achieved the lowest overall RMSE (323.7 m), similar to HW (326.4 m) and significantly better than BL-View (738.3 m). However, all models showed reduced accuracy under stable nighttime conditions, limiting the reliability of PBLH estimates. Key predictors for the model included the lifting condensation level height (LCLH), aerosol gradients, and month for seasonal variability. The study underscores the potential of integrating machine learning with multiple data sets such as surface energy and thermodynamic data to advance PBLH estimation.

boundary layer height↗

Image-derived and arterial blood sampled input functions for quantitative PET imaging of the angiotensin II subtype 1 receptor in the kidney

Purpose: The radioligand {sup 11}C-KR31173 has been introduced for positron emission tomography (PET) imaging of the angiotensin II subtype 1 receptor in the kidney in vivo. To study the biokinetics of {sup 11}C-KR31173 with a compartmental model, the input function is needed. Collection and analysis of arterial blood samples are the established approach to obtain the input function but they are not feasible in patients with renal diseases. The goal of this study was to develop a quantitative technique that can provide an accurate image-derived input function (ID-IF) to replace the conventional invasive arterial sampling and test the method in pigs with the goal of translation into human studies. Methods: The experimental animals were injected with [{sup 11}C]KR31173 and scanned up to 90 min with dynamic PET. Arterial blood samples were collected for the artery derived input function (AD-IF) and used as a gold standard for ID-IF. Before PET, magnetic resonance angiography of the kidneys was obtained to provide the anatomical information required for derivation of the recovery coefficients in the abdominal aorta, a requirement for partial volume correction of the ID-IF. Different image reconstruction methods, filtered back projection (FBP) and ordered subset expectation maximization (OS-EM), were investigated for the best trade-off between bias and variance of the ID-IF. The effects of kidney uptakes on the quantitative accuracy of ID-IF were also studied. Biological variables such as red blood cell binding and radioligand metabolism were also taken into consideration. A single blood sample was used for calibration in the later phase of the input function. Results: In the first 2 min after injection, the OS-EM based ID-IF was found to be biased, and the bias was found to be induced by the kidney uptake. No such bias was found with the FBP based image reconstruction method. However, the OS-EM based image reconstruction was found to reduce variance in the subsequent phase of the ID-IF. The combined use of FBP and OS-EM resulted in reduced bias and noise. After performing all the necessary corrections, the areas under the curves (AUCs) of the AD-IF were close to that of the AD-IF (average AUC ratio =1 ± 0.08) during the early phase. When applied in a two-tissue-compartmental kinetic model, the average difference between the estimated model parameters from ID-IF and AD-IF was 10% which was within the error of the estimation method. Conclusions: The bias of radioligand concentration in the aorta from the OS-EM image reconstruction is significantly affected by radioligand uptake in the adjacent kidney and cannot be neglected for quantitative evaluation. With careful calibrations and corrections, the ID-IF derived from quantitative dynamic PET images can be used as the input function of the compartmental model to quantify the renal kinetics of {sup 11}C-KR31173 in experimental animals and the authors intend to evaluate this method in future human studies.

60 APPLIED LIFE SCIENCES↗

Ion chamber absorbed dose calibration coefficients, N{sub D,w}, measured at ADCLs: Distribution analysis and stability

Purpose: To analyze absorbed dose calibration coefficients, N{sub D,w}, measured at accredited dosimetry calibration laboratories (ADCLs) for client ionization chambers to study (i) variability among N{sub D,w} coefficients for chambers of the same type calibrated at each ADCL to investigate ion chamber volume fluctuations and chamber manufacturing tolerances; (ii) equivalency of ion chamber calibration coefficients measured at different ADCLs by intercomparing N{sub D,w} coefficients for chambers of the same type; and (iii) the long-term stability of N{sub D,w} coefficients for different chamber types by investigating repeated chamber calibrations. Methods: Large samples of N{sub D,w} coefficients for several chamber types measured over the time period between 1998 and 2014 were obtained from the three ADCLs operating in the United States. These are analyzed using various graphical and numerical statistical tests for the four chamber types with the largest samples of calibration coefficients to investigate (i) and (ii) above. Ratios of calibration coefficients for the same chamber, typically obtained two years apart, are calculated to investigate (iii) above and chambers with standard deviations of old/new ratios less than 0.3% meet stability requirements for accurate reference dosimetry recommended in dosimetry protocols. Results: It is found that N{sub D,w} coefficients for a given chamber type compared among different ADCLs may arise from differing probability distributions potentially due to slight differences in calibration procedures and/or the transfer of the primary standard. However, average N{sub D,w} coefficients from different ADCLs for given chamber types are very close with percent differences generally less than 0.2% for Farmer-type chambers and are well within reported uncertainties. Conclusions: The close agreement among calibrations performed at different ADCLs reaffirms the Calibration Laboratory Accreditation Subcommittee process of ensuring ADCL conformance with National Institute of Standards and Technology standards. This study shows that N{sub D,w} coefficients measured at different ADCLs are statistically equivalent, especially considering reasonable uncertainties. This analysis of N{sub D,w} coefficients also allows identification of chamber types that can be considered stable enough for accurate reference dosimetry.

07 ISOTOPE AND RADIATION SOURCES↗

Observation of the Spectrally Invariant Properties of Clouds in Cloudy-to-Clear Transition Zones During the MAGIC Field Campaign

We use the spectrally invariant method to study the variability of cloud optical thickness τau and droplet effective radius r(sub eff) in transition zones (between the cloudy and clear sky columns) observed from Solar Spectral Flux Radiometer (SSFR) and Shortwave Array Spectroradiometer-Zenith (SASZe) during the Marine ARM GPCI Investigation of Clouds (MAGIC) field campaign. The measurements from the SSFR and the SASZe are different, however inter-instrument differences of self-normalized measurements (divided by their own spectra at a fixed time) are small. The spectrally invariant method approximates the spectra in the cloud transition zone as a linear combination of definitely clear and cloudy spectra, where the coefficients, slope and intercept, characterize the spectrally invariant properties of the transition zone. Simulation results from the SBDART (Santa Barbara DISORT Atmospheric Radiative Transfer) model demonstrate that (1) the slope of the visible band is positively correlated with the cloud optical thickness τ while the intercept of the near-infrared band has high negative correlation with the cloud drop effective radius r(sub eff)even without the exact knowledge of τau; (2) the above relations hold for all Solar Zenith Angle (SZA) and for cloud-contaminated skies. In observations using redundant measurements from SSFR and SASZe, we find that during cloudy-to-clear transitions, (a) the slopes of the visible band decrease, and (b) the intercepts of the near-infrared band remain almost constant near cloud edges. The findings in simulations and observations suggest that, while the optical thickness decreases during the cloudy-to-clear transition, the cloud drop effective radius does not change when cloud edges are approached. These results support the hypothesis that inhomogeneous mixing dominates near cloud edges in the studied cases.

spectral invariance↗

Sampling analysis for the Earth Radiation Budget Satellite System mission based on orbital coverage and cloud variability

The reported study represents an extension of an investigation by Harrison et al. (1976). Based on the results of sampling studies, two 98 deg inclined orbits coupled with a 56 deg inclination orbit appear to satisfy the science requirements on both regional and zonal scales. The NOAA sun-synchronous satellites in the TIROS-N series could adequately cover the high latitudes and a satellite having an inclination of 56 deg could provide sampling in the mid and low latitude areas where variations in radiation energetics are most dynamic. Attention is given to studies of time and space coverage, zonal evaluations, a regional analysis, and statistics describing the regional variations of cloud cover. A table is presented with data concerning the uncertainty of monthly mean reflected irradiance due to cloud variability for selected northern hemisphere regions.

Harrison, E. F.↗

Sensitivity of Fine‐Resolution Urban Heat Island Simulations to Soil Moisture Parameterization

ABSTRACT Urban areas experience the impact of natural disasters, such as heatwaves and flash floods, disparately in different neighbourhoods across a city. The demand for precise urban hydrometeorological and hydroclimatological modelling to examine this disparity, and the interacting challenges posed by climate change and urbanisation, has thus surged. The Weather Research and Forecasting (WRF) model has served such operational and research purposes for decades. Recent advancements in WRF, including enhanced numerical schemes and sophisticated urban atmospheric‐hydrological parameterizations, have empowered the simulation of urban geophysical processes at high resolution (~1 km), but even this resolution misses significant urban microclimate variability. This study applies the large‐eddy simulations (LES) mode within WRF, coupled with single‐layer urban canopy models (SLUCM), to enable even finer‐scale modelling (150 m) of the Urban Heat Island (UHI) effect in the Baltimore metropolitan area. We run nine scenarios to evaluate various methods of initializing soil moisture and various spinup lead times, and to assess the impact of WRF's Mosaic approach in depicting subgrid‐scale processes. We evaluate the scenarios by comparing the WRF simulated land surface temperature (LST) against Landsat LST and the WRF simulated hourly 2‐m air temperatures (AT) with observations from eight weather stations across the domain. Results underscore the paramount influence of the lead spinup time on the spatiotemporal distribution of simulated soil moisture, consequently shaping WRF's efficacy in predicting the UHI. Furthermore, interpolating soil moisture‐related parameters from the parent for child domain initialization yields a notable reduction in mean and root‐mean‐squared errors. This improvement was particularly evident in simulations with the longest spinup time, affirming the importance of carefully designing the initialization of soil moisture for improved urban temperature predictions.

Talebpour, Mahdad↗

Thin-layer chromatography and mass spectrometry coupled using proximal probe thermal desorption with electrospray or atmospheric pressure chemica lionization

An atmospheric pressure proximal probe thermal desorption sampling method coupled with secondary ionization by electrospray or atmospheric pressure chemical ionization was demonstrated for the mass spectrometric analysis of a diverse set of compounds (dyestuffs, pharmaceuticals, explosives and pesticides) separated on various high-performance thin-layer chromatography plates. Line scans along or through development lanes on the plates were carried out by moving the plate relative to a stationary heated probe positioned close to or just touching the stationary phase surface. Vapors of the compounds thermally desorbed from the surface were drawn into the ionization region of a combined electrospray ionization/atmospheric pressure chemical ionization source where they merged with reagent ions and/or charged droplets from a corona discharge or an electrospray emitter and were ionized. The ionized components were then drawn through the atmospheric pressure sampling orifice into the vacuum region of a triple quadrupole mass spectrometer and detected using full scan, single ion monitoring, or selected reaction monitoring mode. Studies of variable parameters and performance metrics including the proximal probe temperature, gas flow rate into the ionization region, surface scan speed, read-out resolution, detection limits, and surface type are discussed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Safety and Feasibility of Transradial Access for Visceral Interventions in Patients with Thrombocytopenia

PurposeTransradial access (TRA) has shown lower morbidity and decreased bleeding complications compared to transfemoral access. This study evaluates the safety and feasibility of TRA in thrombocytopenic patients undergoing visceral interventions.Methods and MaterialsPatients who underwent visceral interventions via the radial artery with platelet count less than or equal to 50,000/µL were included in the study. Outcome variables included technical success, access site, bleeding, transfusion, and neurological complications.ResultsFrom July 1, 2012, to May 31, 2015, a total of 1353 peripheral interventions via TRA were performed, of which 85 procedures were performed in 64 patients (mean age 62.2 years) with a platelet count <50,000/µL (median 39,000/µL). Interventions included chemoembolization (n = 46), selective internal radiation therapy (n = 30), and visceral embolization (n = 9). Technical success was 97.6 % with two cases of severe vessel spasm requiring ipsilateral femoral crossover. There was no major access site, bleeding, or neurological adverse events at 30 days. Minor access site hematomas occurred in five cases (5.9 %) and were treated conservatively in all cases. Pre-procedural platelet transfusions were administered in 23 (27.1 %) cases. There was no statistically significant difference in access site or bleeding complications between the transfused and nontransfused groups.ConclusionsTransradial visceral interventions in patients with thrombocytopenia are both feasible and safe, possibly without the need for platelet transfusions.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Asymptotic Behaviour of Ground States for Mixtures of Ferromagnetic and Antiferromagnetic Interactions in a Dilute Regime

We consider randomly distributed mixtures of bonds of ferromagnetic and antiferromagnetic type in a two-dimensional square lattice with probability 1−p and p, respectively, according to an i.i.d. random variable. We study minimizers of the corresponding nearest-neighbour spin energy on large domains in ℤ{sup 2}. We prove that there exists p{sub 0} such that for p≤p{sub 0} such minimizers are characterized by a majority phase; i.e., they take identically the value 1 or − 1 except for small disconnected sets. A deterministic analogue is also proved.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Continuous Dependence on Translations of the Independent Variable for Solutions of Boundary-Value Problems for Differential-Difference Equations

We consider boundary-value problems for differential-difference operators with perturbations in translations of the independent variable. We prove that the family of differential-difference operators is positive definite uniformly with respect to translations of the independent variable. Solutions of such problems depend continuously on these translations. We consider the coercivity problem for differential-difference operators with incommensurable translations of the independent variable and study the approximation of such operators by rational operators.

97 MATHEMATICS AND COMPUTING↗

Capturing Hidden Geochemical Anomalies in Scarce Data by Fractal Analysis and Stochastic Modeling

Fractal/multifractal modeling is a widely used geomathematical approach to capturing different populations in geochemical mapping. The rationale of this methodology is based on empirical frequency density functions attained from global or local distributions. This approach is quite popular because of its simplicity and versatility; it accounts for the frequency and spatial distribution of geochemical data considering self-similarity across a range of scales. Using this technique for detection of geochemical anomalies in scarce data, however, is problematic and can lead to systematic bias in the characterization of the underlying populations. In this paper, an innovative technique is presented that provides good results without a priori assumptions. A simulation approach is adopted for fractal analysis by generating different possible distribution scenarios for the variable under study to reveal the underlying populations that are frequently hidden due to lack of data. The proposed technique is called the global simulated size–number method, and it is validated in a case study with two synthetic datasets and another case study with real dataset from the Ushtagan gold deposit in northeast Kazakhstan.

58 GEOSCIENCES↗

Code Verification and Solution Verification framework in pin-resolved neutron transport code MPACT

Program verification in scientific computing encompasses the application of formal and mathematical techniques to a scientific computing code for its credibility, accuracy, and validity. Code Verification identifies bugs and performance issues in the software development stage. Solution Verification assesses the applicability of the code and the accuracy of the solution to problems of interest. Both activities utilize application cases and quantify the error against prescribed acceptance criteria. However, simply executing more application cases does not guarantee stronger or more comprehensive credibility. Here, we establish a verification framework that involves Code Verification and Solution Verification, both of which work together such that the overarching goal of “converge to the correct answer for the intended application” can be reasonably inferred. The application of such a verification framework is demonstrated using the pin-resolved neutron transport code MPACT, where standard unit tests and regression tests are covered, and where the Method of Exact Solutions and the Method of Manufactured Solutions are successfully used. Additionally, the applicability of Method of Manufactured Solutions is extended to the OECD/NEA C5G7 benchmark problems of practical material and geometric configurations. Solution Verification activities are demonstrated on a practical hierarchy of application models of increasing complexity ranging from 2D pin cell problems to 3D assembly problems. The convergence behavior and rate of convergence with respect to each individual variable are studied and provided. This framework can be adapted broadly to other fields involving scientific computing codes.

97 MATHEMATICS AND COMPUTING↗

Interpretation of the underground muon charge ratio.

The MINOS experiment has observed a rise in the underground muon charge ratio r{sub {mu}} = {mu}{sup +}/{mu}{sup -}. This ratio can be related to the atmospheric production ratios of {pi}{sup +}/{pi}{sup -} and K{sup +}/K{sup -}. Our analysis indicates that the relevant variable for studying the charge ratio is E{sub {mu}}{sup surface} cos {theta}, rather than E{sub {mu}}{sup surface}. We compare a simple energy dependent parameterization of the rise in the charge ratio with more detailed previously published Monte Carlo simulations and an analytical calculation. We also estimate the size of two previously neglected effects in this context: the charge sign dependency of the dE/dx in rock, and the energy dependence of heavy primaries on the derived K{sup +}/K{sup -} ratio.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Accuracy and Utility of Deformable Image Registration in {sup 68}Ga 4D PET/CT Assessment of Pulmonary Perfusion Changes During and After Lung Radiation Therapy

Purpose: Measuring changes in lung perfusion resulting from radiation therapy dose requires registration of the functional imaging to the radiation therapy treatment planning scan. This study investigates registration accuracy and utility for positron emission tomography (PET)/computed tomography (CT) perfusion imaging in radiation therapy for non–small cell lung cancer. Methods: {sup 68}Ga 4-dimensional PET/CT ventilation-perfusion imaging was performed before, during, and after radiation therapy for 5 patients. Rigid registration and deformable image registration (DIR) using B-splines and Demons algorithms was performed with the CT data to obtain a deformation map between the functional images and planning CT. Contour propagation accuracy and correspondence of anatomic features were used to assess registration accuracy. Wilcoxon signed-rank test was used to determine statistical significance. Changes in lung perfusion resulting from radiation therapy dose were calculated for each registration method for each patient and averaged over all patients. Results: With B-splines/Demons DIR, median distance to agreement between lung contours reduced modestly by 0.9/1.1 mm, 1.3/1.6 mm, and 1.3/1.6 mm for pretreatment, midtreatment, and posttreatment (P<.01 for all), and median Dice score between lung contours improved by 0.04/0.04, 0.05/0.05, and 0.05/0.05 for pretreatment, midtreatment, and posttreatment (P<.001 for all). Distance between anatomic features reduced with DIR by median 2.5 mm and 2.8 for pretreatment and midtreatment time points, respectively (P=.001) and 1.4 mm for posttreatment (P>.2). Poorer posttreatment results were likely caused by posttreatment pneumonitis and tumor regression. Up to 80% standardized uptake value loss in perfusion scans was observed. There was limited change in the loss in lung perfusion between registration methods; however, Demons resulted in larger interpatient variation compared with rigid and B-splines registration. Conclusions: DIR accuracy in the data sets studied was variable depending on anatomic changes resulting from radiation therapy; caution must be exercised when using DIR in regions of low contrast or radiation pneumonitis. Lung perfusion reduces with increasing radiation therapy dose; however, DIR did not translate into significant changes in dose–response assessment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of Health Economics in Radiation Oncology: A Systematic Review

Purpose: Despite the rising costs in radiation oncology, the impact of health economics research on radiation therapy practice analysis patterns is unclear. We performed a systematic review of cost-effectiveness analyses (CEAs) and cost-utility analyses (CUAs) to identify trends in reporting quality in the radiation oncology literature over time. Methods and Materials: A systematic review of radiation oncology economic evaluations up to 2014 was performed, using MEDLINE and EMBASE databases. The Consolidated Health Economic Evaluation Reporting Standards guideline informed data abstraction variables including study demographics, economic parameters, and methodological details. Tufts Medical Center CEA registry quality scores provided a basis for qualitative assessment of included studies. Studies were stratified by 3 time periods (1995-2004, 2005-2009, and 2010-2014). The Cochran-Armitage trend test and linear trend test were used to identify trends over time. Results: In total, 102 articles were selected for final review. Most studies were in the context of a model (61%) or clinical trial (28%). Many studies lacked a conflict of interest (COI) statement (67%), a sponsorship statement (48%), a reported study time horizon (35%), and the use of discounting (29%). There was a significant increase over time in the reporting of a COI statement (P<.001), health care payer perspective (P=.019), sensitivity analyses using multivariate (P=.043) or probabilistic methods (P=.011), incremental cost-effectiveness threshold (P<.001), secondary source utility weights (P=.010), and cost effectiveness acceptability curves (P=.049). There was a trend toward improvement in Tuft scores over time (P=.065). Conclusions: Recent reports demonstrate improved reporting rates in economic evaluations; however, there remains significant room for improvement as reporting rates are still suboptimal. As fiscal pressures rise, we will rely on economic assessments to guide our practice decisions and policies. We recommend improved adherence to published guidelines and further research to determine the clinical implications of our findings.

62 RADIOLOGY AND NUCLEAR MEDICINE↗