Search NASA⌕ Search

SEARCH · Search NASA

Results for “vertically aligned”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 595 records · Page 33

Alignment and Testing of a Telecentric Zoom Lens Used for the Cygnus X-ray Source

Cygnus is a high-energy radiographic x-ray source. Three large zoom lenses have been assembled to collect images from large scintillators. A large elliptical pellicle (394 × 280 mm) deflects the scintillator light out of the x-ray path into an eleven-element zoom lens coupled to a CCD camera. The zoom lens and CCD must be as close as possible to the scintillator to maximize light collection. A telecentric lens design minimizes image blur from a volume source. To maximize the resolution of objects of different sizes, the scintillator and zoom lens are translated along the x-ray axis, and the zoom lens magnification changes. Zoom magnification is also changed when different-sized recording cameras are used (50 or 62 mm square format). The LYSO scintillator measures 200 × 200 mm and is 5 mm thick. The scintillator produces blue light peaking at 435 nm, so special lens materials are required. By swapping out one doublet and allowing all other lenses to be repositioned, the zoom lens can also use a CsI(Tl) scintillator that produces green light centered at 540 nm (for future operations). All lenses have an anti-reflective coating for both wavelength bands. Two sets of doublets, the stop, the scintillator, and the CCD camera move during zoom operations. One doublet has x-y compensation. Alignment of the optical elements was accomplished using counter propagating laser beams and monitoring the retro-reflections and steering collections of laser spots. Each zoom lens uses 60 lb of glass inside the 425 lb mechanical structure, and can be used in either vertical or horizontal orientation.

zoom lens, telecentric lens design, optical metrol↗

SU-E-J-237: Image Feature Based DRR and Portal Image Registration

Purpose: Two-dimensional (2D) matching of the kV X-ray and digitally reconstructed radiography (DRR) images is an important setup technique for image-guided radiotherapy (IGRT). In our clinics, mutual information based methods are used for this purpose on commercial linear accelerators, but with often needs for manual corrections. This work proved the feasibility that feature based image transform can be used to register kV and DRR images. Methods: The scale invariant feature transform (SIFT) method was implemented to detect the matching image details (or key points) between the kV and DRR images. These key points represent high image intensity gradients, and thus the scale invariant features. Due to the poor image contrast from our kV image, direct application of the SIFT method yielded many detection errors. To assist the finding of key points, the center coordinates of the kV and DRR images were read from the DICOM header, and the two groups of key points with similar relative positions to their corresponding centers were paired up. Using these points, a rigid transform (with scaling, horizontal and vertical shifts) was estimated. We also artificially introduced vertical and horizontal shifts to test the accuracy of our registration method on anterior-posterior (AP) and lateral pelvic images. Results: The results provided a satisfactory overlay of the transformed kV onto the DRR image. The introduced vs. detected shifts were fit into a linear regression. In the AP image experiments, linear regression analysis showed a slope of 1.15 and 0.98 with an R2 of 0.89 and 0.99 for the horizontal and vertical shifts, respectively. The results are 1.2 and 1.3 with R2 of 0.72 and 0.82 for the lateral image shifts. Conclusion: This work provided an alternative technique for kV to DRR alignment. Further improvements in the estimation accuracy and image contrast tolerance are underway.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-E-T-588: Characterization and Clinical Validation of the Varian Pivotal™ Treatment Solution for Prone Breast Care

Purpose: To report on the clinical validation of the Varian Pivotal™ Treatment Solution for Prone Breast Care: a platform for prone breast radiation therapy. Methods: Patients treated using Breast Conserving Radiation Therapy may benefit from treatment in the prone position with the breast tissue falling freely away from the body. This geometry allows the breast tissue to be treated while avoiding the lung and heart tissue. Eighteen patients simulated and treated using the Varian Medical Systems Pivotal™ Treatment Solution for Prone Breast Care were monitored over the course of treatment for positioning integrity and reproducibility. As this carbon-fiber platform actually replaces a portion of the couch top, indexing is inherent to its design. Patients were positioned on the couch and aligned using fiducial markers and lateral SSD to the breast fiducial point. The daily couch coordinates then serves as indicators for positioning variability with this system. Results: The variations in couch vertical, longitudinal and lateral positions were centered on a mean value of zero with standard deviations of 0.44cm, 0.75cm and 0.79cm respectively. Other factors explored were variations in distance of mid-sternum to table edge and patient rotation into the opening. The median rotation of the chest wall was found to be 11.5 degrees at CT-Simulation with a median distance of 2.5cm from midsternum to support opening. Patient rotation was not associated with either breast size or distance from edge of platform. Conclusion: The Pivotal™ Treatment solution consists of a couch top that replaces the standard top and as such is open from beneath without obstruction. This is a distinction from all other solutions which rely on a platform positioned above and indexed to the treatment couch. We found the reproducibility to be consistent with our historical measures while offering benefits of an integrated solution as stated above. supported by Professional Services Agreeement with Varian Medical Systems.

60 APPLIED LIFE SCIENCES↗

Three-dimensional photonic crystals by large-area membrane stacking

We designed and analyzed a “mesh-stack” three-dimensional photonic crystal of a 12.4% bandgap with a dielectric constant ratio of 12:1. The mesh-stack consists of four offset identical square-lattice air-hole patterned membranes in each vertical period that is equal to the in-plane period of the square lattice. This design is fully compatible with the membrane-stacking fabrication method, which is based on alignment and stacking of large-area single-crystal membranes containing engineered defects. A bandgap greater than 10% is preserved as long as the membranes are subjected to in-plane misalignment less than 3% of the square period. By introducing a linear defect with a nonsymmorphic symmetry into the mesh-stack, we achieved a single-mode waveguide over a wide bandwidth.

36 MATERIALS SCIENCE↗

Systems for passive microwave remote sensing and their calibration methods

A system for passive microwave remote sensing using at least one microwave radiometer includes a fixed body portion, the fixed body portion being configured to attach to a mobile platform, and a mobile body portion, the mobile body portion being configured for rotatably coupling with the fixed body portion for rotation about a rotation axis. The mobile body portion is configured for supporting the at least one microwave radiometer therein such that the at least one microwave radiometer rotates about the rotation axis when the mobile body portion is rotated about the rotation axis such that a polarization axis of the at least one radiometer is aligned with an earth axis. The fixed body portion includes a motor mechanism for effecting rotation of the mobile body portion such that the at least one microwave radiometer provides a vertical scanning below and above the mobile platform.

Klein, Marian↗

Polarization ratio enhancement of a-plane GaN light emitting diodes by asymmetric two-dimensional photonic crystals

Fabricating photonic crystals (PhCs) on GaN based non-polar light emitting diodes (LEDs) is an effective way to increase light extraction and meanwhile to preserve or improve polarization ratio. In this work, a-plane GaN LEDs with two-dimensional PhCs were demonstrated. With the E // m polarized modes (which mean the optical polarization with the electric field parallel to m-axis) as the target of diffraction, we matched E//m modes to the photonic bands and aligned E//c modes to fall within the photonic band gap. The results show stronger E//m but weaker E//c mode diffractions on both c- and m-axes. At the vertical direction, the polarization ratio is enhanced from 45.8% for the planar device to 52.3% for the LEDs with PhCs.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Imaging microscopic electronic contrasts at the interface of single-layer WS 2 with oxide and boron nitride substrates

The electronic properties of devices based on two-dimensional materials are significantly influenced by interactions with the substrate and electrode materials. In this work, we use photoemission electron microscopy to investigate the real- and momentum-space electronic structures of electrically contacted single-layer WS 2 stacked on hBN, SiO 2 , and TiO 2 substrates. Furthermore, using work function and X-ray absorption imaging, we single-out clean microscopic regions of each interface type and collect the valence band dispersion. We infer the alignments of the electronic bandgaps and electron affinities from the measured valence band offsets of WS2 and the three substrate materials using a simple electron affinity rule and discuss the implications for vertical band structure engineering using mixed three- and two-dimensional materials.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Thermal deflection in neutron scattering sample environments at Oak Ridge National Laboratory

The neutron sources at Oak Ridge National Laboratory use a wide suite of sample environment equipment to deliver extreme conditions for a number of experiments. Much of this instrumentation focuses on extremes of temperature, such as cryostats, closed-cycle refrigerators in both low and high temperature configurations, and radiant heating furnaces. When the temperature is controlled across a large range, thermal deflection effects can notably move the sample and affect its alignment in the beam. Here, we combine these sample environments with neutron imaging and machine vision to determine the motion of a representative sample with respect to the neutron beam. We find vertical sample displacement on the order of 1–2 mm and horizontal displacement that varies from near-negligible to 1.2 mm. While these deflections are not relevant for some of the beamlines at the first target station at the spallation neutron source and the high flux isotope reactor, they will become critical for upcoming instrumentation at the second target station, as well as any instruments targeting sub-mm samples, as neutron sources and optics evolve to smaller and more focused beams. We discuss mitigation protocols and potential modifications to the environment to minimize the effect of misalignment due to thermal deflection.

47 OTHER INSTRUMENTATION↗

Analysis of Doppler Lidar Data Acquired During the Pentagon Shield Field Campaign

Observations from two coherent Doppler lidars deployed during the Pentagon Shield field campaign are analyzed in conjunction with other sensors to characterize the overall boundary-layer structure, and identify the dominant flow characteristics during the entire two-week field campaign. Convective boundary layer (CBL) heights and cloud base heights (CBH) are estimated from an analysis of the lidar signal-to-noise-ratio (SNR), and mean wind profiles are computed using a modified velocity-azimuth-display (VAD) algorithm. Three-dimensional wind field retrievals are computed from coordinated overlapping volume scans, and the results are analyzed by visualizing the flow in horizontal and vertical cross sections. The VAD winds show that southerly flows dominate during the two-week field campaign. Low-level jets (LLJ) were evident on all but two of the nights during the field campaign. The LLJs tended to form a couple hours after sunset and reach maximum strength between 03 and 07 UTC. The surface friction velocities show distinct local maxima during four nights when strong LLJs formed. Estimates of the convective boundary layer height and residual layer height are obtained through an analysis of the vertical gradient of the lidar signal-to-noise-ratio (SNR). Strong minimum in the SNR gradient often develops just above the surface after sunrise. This minimum is associated with the developing CBL, and increases rapidly during the early portion of the daytime period. On several days, this minimum continues to increase until about sunset. Secondary minima in the SNR gradient were also observed at higher altitudes, and are believed to be remnants of the CBL height from previous days, i.e. the residual layer height. The dual-Doppler analysis technique used in this study makes use of hourly averaged radial velocity data to produce three-dimensional grids of the horizontal velocity components, and the horizontal velocity variance. Visualization of horizontal and vertical cross sections of the dual-Doppler wind retrievals often indicated a jet-like flow feature over the Potomac River under southerly flow conditions. This linear flow feature is roughly aligned with the Potomac River corridor to the south of the confluence with the Anatostia River, and is most apparent at low levels (i.e. below ~150 m MSL). It is believed that this flow arises due to reduced drag over the water surface and when the large scale flow aligns with the Potomac River corridor. A so-called area-constrained VAD analysis generally confirmed the observations from the dual-Doppler analysis. When the large scale flow is southerly, wind speeds over the Potomac River are consistently larger than the at a site just to the west of the river for altitudes less than 100 m MSL. Above this level, the trend is somewhat less obvious. The data suggest that the depth of the wind speed maximum may be reduced by strong directional shear aloft.

54 ENVIRONMENTAL SCIENCES↗

Optimizing the operation of a high resolution vertical Johann spectrometer using a high energy fluorescer x-ray source

This paper describes the operation and testing for a vertical Johann spectrometer (VJS) operating in the 13 keV range. The spectrometer is designed to use thin curved mica crystals or thick germanium crystals. The VJS must have a resolution of E/{Delta}E=3000 or better to measure the Doppler broadening of highly ionized krypton and operate at a small x-ray angle in order to be used as a diagnostic in a laser plasma target chamber. The VJS was aligned, tested, and optimized using a fluorescer type high energy x-ray (HEX) source located at National Security Technologies (NSTec), LLC, in Livermore, CA. The HEX uses a 160 kV x-ray tube to excite fluorescence from various targets. Both rubidium and bismuth fluorescers were used for this effort. This presentation describes the NSTec HEX system and the methods used to optimize and characterize the VJS performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Designing Ta C Virtual Substrates for Vertical Al x Ga 1 − x N Power Electronics Devices

Power electronics are critical for a sustainable energy future, playing a key role in electrification and integration of renewable energy sources into the grid. Advances in ultrawide band gap materials are needed to handle higher powers in smaller form factors while reducing electrical and thermal losses. High Al content Al x Ga 1 − x N is theoretically capable of meeting these demands, but its impact in power electronics has been severely restricted by a lack of substrates that can satisfy conductivity, lattice matching, and/or thermal expansion requirements. We demonstrate that electrically conductive Ta C can be used as a virtual substrate for Al x Ga 1 − x N heteroepitaxy. Scaleably sputtered Ta C grown on Al 2 O 3 , followed by high-temperature face-to-face annealing, produces a thin film Ta C template with an effective hexagonal lattice constant matched to Al 0.70 Ga 0.30 N . Annealing of the Ta C promotes recrystallization, significantly improving crystallinity and reducing crystalline defects from as-deposited columnar grains to a step-and-terrace surface morphology, enabling the subsequent growth of high-quality Al 0.70 Ga 0.30 N by molecular beam epitaxy. X-ray diffraction and scanning transmission electron microscopy confirm that the Al x Ga 1 − x N layer is heteroepitaxially aligned, strain-free, and lattice-matched, transitioning abruptly from Ta C to Al x Ga 1 − x N without intermediate phases. These results demonstrate Ta C virtual substrates as electrically conductive, lattice-matched, and thermally compatible templates for vertical Al x Ga 1 − x N devices that can meet the growing power needs of a sustainable energy future. Published by the American Physical Society 2024

36 MATERIALS SCIENCE↗

Beam-Based Alignment, Tuning and Beam Dynamics Studies for the ATF2 Extraction Line and Final Focus System

Using a new extraction line currently under construction, the ATF2 experiment plans to test the novel compact final focus optics design with local chromaticity correction intended for use in future linear colliders. With a 1.3 GeV design beam of 30nm normalized vertical emittance extracted from the ATF damping ring, the primary goal is to achieve a vertical spot-size at the IP waist of 37nm. We discuss our planned strategy for tuning the ATF2 beam to meet the primary goal. Simulation studies have been performed to asses the effectiveness of the strategy, including 'static' (installation) errors and dynamical effects (ground-motion, mechanical vibration, ring extraction jitter etc.). We have simulated all steps in the tuning procedure, from initial orbit establishment to final IP spot-size tuning. Through a Monte Carlo study of 100's of simulation seeds we find we can achieve a spot-size within {approx}10% of the design optics value in at least 75% of cases. We also ran a simulation to study the long-term performance with the use of beam-based feedbacks.

43 PARTICLE ACCELERATORS↗

Development and applications of a two-dimensional tip-tilting stage system with nanoradian-level positioning resolution

In this paper, designs of a novel rotary weak-link stage for a vertical rotation axis and a two-dimensional tip-tilting system are presented. Applications of these new stage systems include: an advanced X-ray stereo imaging instrument for particle tracking velocimetry, an alignment stage system for hard X-ray nano-focusing Montel mirror optics, and an ultra-precision crystal manipulator for cryo-cooling optical cavities of an X-ray free-electron-laser oscillator (XFELO).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cryogen-free modular scanning tunneling microscope operating at 4-K in high magnetic field on a compact ultra-high vacuum platform

One of the daunting challenges in modern low temperature scanning tunneling microscopy (STM) is the difficulty of combining atomic resolution with cryogen-free cooling. Further functionality needs, such as ultra-high vacuum (UHV), high magnetic field (HF), and compatibility with μm-sized samples, pose additional challenges to an already ambitious build. We present the design, construction, and performance of a cryogen-free, UHV, low temperature, and high magnetic field system for modular STM operation. An internal vibration isolator reduces vibrations in this system, allowing for atomic resolution STM imaging while maintaining a low base temperature of ∼4 K and magnetic fields up to 9 T. Samples and tips can be conditioned in situ utilizing a heating stage, an ion sputtering gun, an e-beam evaporator, a tip treater, and sample exfoliation. In situ sample and tip exchange and alignment are performed in a connected UHV room temperature stage with optical access. Multisite operation without breaking vacuum is enabled by a unique quick-connect STM head design. A novel low-profile vertical transfer mechanism permits transferring the STM between room temperature and the low temperature cryostat.

Instruments & Instrumentation↗

A 20 Gbps PAM4 data transmitter ASIC for particle physics experiments

We present the design and test results of a novel data transmitter ASIC operating up to 20.48 Gbps with 4-level Pulse-Amplitude-Modulation (PAM4) for particle physics experiments. This ASIC, named GBS20, is fabricated in a 65 nm CMOS technology. Two serializers share a 5.12 GHz Phase Locked Loop (PLL) clock. The outputs from the serializers are combined into a PAM4 signal that directly drives a Vertical-Cavity-Surface-Emitting-Laser (VCSEL). The input data channels, each at 1.28 Gbps, are scrambled with an internal 2$^{7}$-1 Pseudo-Random Binary Sequence (PRBS), which also serves as a frame aligner. GBS20 is tested to work at 10.24 and 20.48 Gbps with a VCSEL-based Transmitter-Optical-Subassembly (TOSA). The power consumption of GBS20 is below 238 mW and reduced to 164 mW in the low-power mode.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measuring the Radial Component of the Magnetic Field in the Muon g-2 Experiment

A leading systematic error in the muon electric dipole moment (EDM) analysis at Muon g-2 is the presence of radial magnetic fields because they cause indistinguishable effects to the muon spin precession plane from a true EDM measurement. Measuring a non-zero EDM would place a constraint in CP-violation, indicating new physics beyond the Standard Model. The radial field is composed of an applied radial field by the surface correction coils (SCC) and a background radial field due to imperfections in the materials and alignment of magnetic elements. We determine an optimal SCC setting that best minimizes the background radial field by performing a scan at different electro-static quadrupole settings and studying its relation with the vertical beam position and applied radial field. In this talk I will present our results and describe our efforts to design an apparatus outfitted with Hall probes and tilt sensors to directly measure the radial magnetic field as a function of az imuth.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Magnetic Materials Research at SRNL

Fig: Rietveld Refinement of room temperature PXRD data for annealed Ce2Fe14B (left panel), (Y0.1Ce1.9)Fe14B (middle panel), and (Lu0.1Ce1.90)Fe14B (right panel) alloys. All annealed alloys plotted are composed primarily of Ce2Fe14B phase with small α-Fe impurities. Vertical blue ticks correspond to the position of the calculated Bragg peaks of all phases (from top to bottom, 2-14-1 and α-Fe). Fig: (Left Panel) Field dependent magnetization measurements on aligned powder with the magnetic field applied along the easy direction for annealed Ce2Fe14B and (YxCe2-x)Fe14B (x=0.1, 0.2, 0.3, 0.4, 0.5) alloys. (Middle Panel) Field dependent magnetization measurements on aligned powder with the magnetic field applied along the hard direction for annealed Ce2Fe14B and (YxCe2-x)Fe14B (x=0.1, 0.2, 0.3, 0.4, 0.5) alloys. (Right Panel) The saturation magnetization of Ce2Fe14B and (YxCe2-x)Fe14B (x=0.1, 0.2, 0.3, 0.4, 0.5) alloys as determined from easy axis field dependent magnetization measurements.

Bretana, Alex↗