Search NASA⌕ Search

SEARCH · Search NASA

Results for “(alpha)-variation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Absolute calibration of the Lyman-α measurement apparatus at DIII-D

The LLAMA (Lyman-Alpha Measurement Apparatus) diagnostic was recently installed on the DIII-D tokamak [Rosenthal et al., Rev. Sci. Instrum. (submitted) (2020)]. LLAMA is a pinhole camera system with a narrow band Bragg mirror, a bandpass interference filter, and an absolute extreme ultraviolet photodiode detector array, which measures the Ly-α brightness in the toroidal direction on the inboard, high field side (HFS) and outboard, low field side (LFS). This contribution presents a setup and a procedure for an absolute calibration near the Ly-α line at 121.6 nm. The LLAMA in-vacuum components are designed as a compact, transferable setup that can be mounted in an ex situ vacuum enclosure that is equipped with an absolutely calibrated Ly-α source. The spectral purity and stability of the Ly-α source are characterized using a vacuum ultraviolet spectrometer, while the Ly-α source brightness is measured by a NIST-calibrated photodiode. The non-uniform nature of the Ly-α source emission was overcome by performing a calibration procedure that scans the Ly-α source position and employs a numerical optimization to determine the emission pattern. Nominal and measured calibration factors are determined and compared, showing agreement within their uncertainties. A first conversion of the measured signal obtained from DIII-D indicates that the Ly-α brightness on the HFS and LFS is on the order of 1020 Ph sr-1 m-2 s-1. The established calibration setup and procedure will be regularly used to re-calibrate the LLAMA during DIII-D vents to monitor possible degradation of optical components and detectors.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

High-resolution radiation detection using Ni/SiO 2 /n-4H-SiC vertical metal-oxide-semiconductor capacitor

In this article, we demonstrate the radiation detection performance of vertical metal-oxide-semiconductor (MOS) capacitors fabricated on 20 μm thick n-4H-SiC epitaxial layers with the highest energy resolution ever reported. The 100 nm SiO2 layer was achieved on the Si face of n-4H-SiC epilayers using dry oxidation in air. The Ni/SiO2/n-4H-SiC MOS detectors not only demonstrated an excellent energy resolution of 0.42% (ΔE/E 100) for 5.48 MeV alpha particles but also caused a lower enhancement in the electronic noise components of the spectrometer compared with that observed for the best high-resolution Schottky barrier detectors. The MOS detectors also exhibited a high charge collection efficiency (CCE) of 96% at the optimized operating bias despite the presence of the oxide layer. A drift-diffusion model applied to the CCE vs gate bias voltage data revealed a minority (hole) carrier diffusion length of 24 μm. Capacitance mode deep level transient spectroscopy (C-DLTS) scans in the temperature range 84–800 K were carried out to identify the resolution limiting electrically active defects. Interestingly, the C-DLTS spectra revealed both positive and negative peaks, indicating the simultaneous presence of electron (majority) and hole (minority) trap centers. It has been inferred that at the steady-state bias for the C-DLTS measurement, the MOS detector operates in the inversion mode at certain device temperatures, causing holes to populate the minority trap centers and, hence, manifests minority carrier peaks as well.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Single-event burnout in homojunction GaN vertical PiN diodes with hybrid edge termination design

GaN devices play a major role in modern electronics, providing high-power handling, efficient high-frequency operation, and resilience in harsh environments. However, electric field crowding at the edge of the anode often limits its full potential, leading to single-event effects (SEEs) at lower bias voltages under heavy ion radiation. Here, in this work, we report on the performance of homojunction GaN vertical PiN diodes with a hybrid edge termination design under heavy ion irradiation, specifically, oxygen ions, chlorine ions, Cf-252 fission fragments, and alpha particles from an Am-241 source. The unique hybrid edge termination (HET) design provides better electric field management, preventing breakdown from occurring at the edge of the anode at lower voltages. The results of this study reveal that these devices exhibit excellent tolerance to 12-MeV oxygen and 16-MeV chlorine ions, owing to their low linear energy transfer (LET) and range in GaN. However, single-event burnout (SEB) is observed during the Cf-252 exposure at about 50% of the diodes' electrical breakdown voltage due to the presence of higher LET and longer-range ions. Optical and scanning electron microscopy (SEM) reveal that the damage that caused by SEB lies close to the center of these devices rather than the anode edge. Devices with junction termination extension (JTE) instead of HET edge termination also show similar SEB when irradiated with Cf-252 fission fragments. Physical damage due to SEB occurs at the edge of the anode for these devices. These comparative results show the benefits of HET for enhancing the resistance of GaN-based PiN diodes to heavy ion irradiation.

42 ENGINEERING↗

Reproducibility of real-time time-dependent density functional theory calculations of electronic stopping power in warm dense matter

Real-time time-dependent density functional theory (TDDFT) is widely considered to be the most accurate available method for calculating electronic stopping powers from first principles, but there have been relatively few assessments of the consistency of its predictions across different implementations. This problem is particularly acute in the warm dense regime, where computational costs are high and experimental validation is rare and resource intensive. We report a comprehensive cross-verification of stopping power calculations in conditions relevant to inertial confinement fusion conducted using four different TDDFT implementations. We find excellent agreement among both the post-processed stopping powers and relevant time-resolved quantities for alpha particles in warm dense hydrogen. We also analyze sensitivities to a wide range of methodological details, including the exchange-correlation model, pseudopotentials, initial conditions, observable from which the stopping power is extracted, averaging procedures, projectile trajectory, and finite-size effects. We show that among these details, pseudopotentials, trajectory-dependence, and finite-size effects have the strongest influence, and we discuss different strategies for controlling the latter two considerations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

First look at neutron emission shape characteristics of ignition hotspots at the National Ignition Facility (invited)

The nuclear imaging system has been capturing neutron images of inertial confinement fusion (ICF) driven implosions for over a decade at the National Ignition Facility. This imaging system has evolved from one to three nearly orthogonal lines-of-sight, allowing for the study of three-dimensional shape characteristics of ignition shots. Limited-view tomography algorithms help visualize the burning hotspot in 3D and assess neutron source geometry using Legendre mode parameters. With its neutron, gamma-ray, and x-ray image reconstruction capabilities, NIS has provided critical insight into mechanisms that have limited implosion performance, such as fill tube diameter for ignition-type targets. This comprehensive diagnostic suite opens a window into the shape characteristics of ignition shots and how symmetry affects ICF implosion performance. In more recent ignition shots, neutron yields have visibly increased. Analyzing the shape and size of the reconstructed neutron source has shown an expansion of the burn volume, which is indicative of more efficient alpha heating during the implosion process.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

De novo designed protein inhibitors of amyloid aggregation and seeding

Neurodegenerative diseases are characterized by the pathologic accumulation of aggregated proteins. Known as amyloid, these fibrillar aggregates include proteins such as tau and amyloid-β (Aβ) in Alzheimer’s disease (AD) and alpha-synuclein (αSyn) in Parkinson’s disease (PD). The development and spread of amyloid fibrils within the brain correlates with disease onset and progression, and inhibiting amyloid formation is a possible route toward therapeutic development. Recent advances have enabled the determination of amyloid fibril structures to atomic-level resolution, improving the possibility of structure-based inhibitor design. In this work, we use these amyloid structures to design inhibitors that bind to the ends of fibrils, “capping” them so as to prevent further growth. Using de novo protein design, we develop a library of miniprotein inhibitors of 35 to 48 residues that target the amyloid structures of tau, Aβ, and αSyn. Biophysical characterization of top in silico designed inhibitors shows they form stable folds, have no sequence similarity to naturally occurring proteins, and specifically prevent the aggregation of their targeted amyloid-prone proteins in vitro. The inhibitors also prevent the seeded aggregation and toxicity of fibrils in cells. In vivo evaluation reveals their ability to reduce aggregation and rescue motor deficits in Caenorhabditis elegans models of PD and AD.

59 BASIC BIOLOGICAL SCIENCES↗

Development of a tomographic reconstruction method for axisymmetric D α emission profiles in the ITER plasma boundary

A tomographic method for reconstructing the axially symmetric D α emission profile in the ITER scrape-off layer and divertor from D α intensity measurements in the fields of view (FoV) of Vis/IR TV and Divertor Impurity Monitor diagnostics is under development. The method takes into account the strong background signal due to stray light from divertor produced by reflections from the metal wall of the vacuum chamber. The method allows to filter out the reflections in D α signals measured in the main chamber. Here, the accuracy of this method is tested within the framework of a synthetic diagnostic, which uses the Raysect and Cherab numerical codes for ray-tracing simulations. The D α emission profiles, simulated with the SOLPS and OEDGE codes, are used as synthetic experimental data. Uncertainty in light reflection properties of the first wall (FW) is the major factor affecting the accuracy of the D α emission reconstruction. The dependence on the uncertainty in the FW surface roughness and on the ratio of diffusive to specular reflection of the error in recovering useful D α signals (the direct light without reflections) in the FoV of the ITER main chamber H-alpha and Visible Spectroscopy Diagnostic is obtained.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Radiation induced non-linear oscillations in ITER baseline scenario plasmas in DIII-D

Abstract This work shows how the radiation brought about by metals or metal-equivalent radiators such as Kr and Xe produces non-linear dynamics on otherwise stationary β N flattops of DIII-D ITER Baseline Scenario demonstration discharges. The Kr and Xe gases are used to reproduce the radiative loss rates of W in present machines that operate at core temperatures much lower than the expected ITER temperature. Experiments on DIII-D with injection of Kr and Xe, as well as with sources of intrinsic metals reach the range of radiated fraction values expected in the ITER core and experience slow oscillations in temperature and radiated power. In many cases of high radiated fraction, the core temperature decreases enough for the safety factor profile to rise above the 1/1 rational surface, naturally eliminating sawteeth and occasionally producing a persistent helical core. The oscillations can be reproduced by a modified Lotka–Volterra system for temperature and radiated fraction if diffusion and noise are included, which indicates that the interplay between temperature and radiation can be the main cause of the cyclic nature of the system. A new physics based model which includes equations for temperature, density and input power can also reproduce the oscillations observed in the experiments. The present results suggest that the non-linearity of the system can be increased by the inclusion of the inherently non-linear alpha heating term, which is proportional to ∼ n e 2 T i 2 , and obtains oscillations in the model when added to an otherwise more stationary system.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Fast ion studies in the extended high-performance high β P plasma on EAST

Comprehending and optimizing fast ion behaviors is critical for the enhancement of performance in Experimental Advanced Superconducting Tokamak (EAST). This study explores the potential benefits of several factors that can improve the fast ion confinement. First, experiments show the change in the direction of the NBI2 from counter-I p to co-I p leads to a significant reduction in fast ion losses. TRANSP/NUBEAM simulation and tomography results based on fast-ion D-alpha measurements reveal that after the neutral beam injection (NBI) upgrade, the beam ion prompt loss is reduced by approximately 50%. Second, the upgraded ion cyclotron resonant frequency (ICRF) antenna at the N-port features twice the coupling resistance of the original antennas at EAST. This improved ICRF power coupling has enhanced the synergistic heating effect of NBI + ICRF, where the ICRF wave field accelerates beam ions at the harmonics. Experiments demonstrate that NBI + ICRF synergistic not only enhances plasma neutron yield and β P , but also accelerates beam ions to hundreds of keV. Further, the electron density and the neutral beam voltage have been optimized to reduce the fast ion slowing-down time and beam ion losses. Experimental and simulation results indicate that increasing the electron density reduces beam ion losses and enhances the bootstrap current fraction. While higher beam voltage results in a slight decrease in beam power absorption, it can increase the fraction of bootstrap current. With the understanding of these optimization of fast ion confinement, experiments have demonstrated fully non-inductive operation at high density (n e /n G ∼ 0.67, β P ∼ 3.1, β N ∼ 2.1, H 98,y2 ∼ 1.2) even without the support of co-I p beam NBI2. This investigation presents a potential regime to enhance fast ion confinement and extend performance in the high β P plasma for future experiments.

EAST tokamak↗

$\mathrm{α}$ decay of the longest-lived Cm isotope: $^{247}_{96}\mathrm{Cm}$

We report alpha decay of 247 Cm was studied fifty years ago using a 1.6 Bq source containing 99.4 % 247 Cm and levels in 243 Pu were deduced. Using the same source, γ-ray spectra were measured with a more efficient Ge detector. A γ-ray spectrum was also measured in coincidence with α particles for a period of two months and has 80 times more counts than the previously published spectrum. Gamma-ray energies were determined with higher precision and four new γ rays were identified. A new high-energy γ ray of 564.5 keV was observed, which is interpreted as a transition between a level at 564.5 keV and the ground state of 243 Pu. The 564.5-keV level has been tentatively assigned to the 7/2 - [743] Nilsson state.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

α decay of the neutron-deficient isotope At 190

The alpha decay of the neutron-deficient 190 At isotope was observed following the 103 Rh( 90 Zr, 3n) 190 At reaction at Argonne National Laboratory. The reaction products were separated from the beam using the Argonne Gas-Filled Analyzer and implanted into a double-sided Si strip detector. The spatial and temporal correlations between implanted nuclei and subsequent α decays towards the known daughter isotope 186 Bi were used to identify and characterize 190 At nuclei. In this paper, two possible decay scenarios are proposed for the 190 At → 186 Bi decay.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Comparison of NMC estimates with trans-stilbene, EJ-309, and He-3 detection systems

Neutron multiplicity counting (NMC) is a technique for the assay of fissile material. In this work, three detection systems are utilized for active interrogation assay of shells of the Rocky Flats shells (highly enriched uranium, 93% 235U) stacked from 13.25-54.92 kg assemblies. The singles ($R_1$) and doubles ($R_2$) rates are calculated with each system to estimate two sample parameters: $M_L$- the leakage multiplication and F - the sample fission rate. The estimated mass, m, is found by dividing F by a constant activity per unit mass. Since we are interrogating HEU, the α ratio of (α; n) to fission neutrons is taken to be zero. The system of equations to calculate these quantities was originally derived. The Neutron Multiplicity 3 He Array Detector (NOMAD) consists of 15 3 He tubes inside polyethylene and is the traditional, capture-based detection system for NMC. The polyethylene moderates incoming neutrons for thermal capture in individual tubes. The low gamma background, discrete capture signals, and high efficiency of the NOMAD are beneficial for NMC. However, the time to slow down neutrons to thermal energies leads to a system die away time on the scale of microseconds. Comparatively, the Rossi-alpha Measurements – Rapid Organic (n, γ) Discrimination Detector (RAMRODD) and the Organic Scintillator Array (OSCAR) are scatter-based detection systems. RAMRODD consists of 8, 5.08 by 5.08 cm EJ-309 liquid scintillators in 4 pairs, evenly-spaced with 90 degrees separation about the center of each assembly. OSCAR consists of a single array of 12, 5.08 by 5.08 cm trans-stilbene crystals aligned with the center of the assembly. Scatter-based systems detect fast neutrons without any moderation, leading to system die away times on the scale of tens of nanoseconds. This allows much shorter timing gate widths compared to thermal systems, thus increasing counting statistics of true correlated fission events. However, scatter-based systems are susceptible to neutron cross-talk when an incident neutron scatters off one detector and interacts in an adjacent detector, causing two seemingly correlated detection signals. The equations developed adjust for cross-talk to conduct NMC with scatter-based systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

EUCLID Sensitivity Database

This report documents the EUCLID sensitivity database along with its several use-cases. EUCLID computed sensitivities for the following integral responses: Criticality of ICSBEP critical assemblies, LLNL pulsed-sphere neutron-leakage spectra, reaction rates in selected ICBSEP critical assemblies, delayed neutron factions of selected ICSBEP critical assemblies, reactivity coefficients in two ICSBEP critical assemblies, sub-critical assembly responses and Rossi-alpha of selected critical assemblies. It is described for each response what the reported observable constitutes, the method we used to obtain the sensitivities, and which integral experiments were studied. It is also documented briefly in what format these sensitivities are stored. These sensitivities were used for many aspects of the EUCLID project, like ML-supported large-scale nuclear-data validation, or optimization of integral experiments. But these sensitivities can also be applied for more established processes in the nuclear-data application field such as adjustment or assessing the upper sub-critical limit.

Delayed Neutron Fraction↗

Analysis of a Bulk 237 Np Oxide Sample for Trace Actinides

A neptunium oxide sample was dissolved and trace actinide constituents were measured by isotope dilution ICP-MS (for 239–244 Pu, 233–238 U, 237 Np, 241–243 Am) and alpha spectrometry ( 238 Pu, 242 Cm, 244 Cm). This material contained significant quantities of transuranic elements, notably americium and curium. The isotopic composition of the material will continue to evolve over time due to radioactive decay; the measurements reported here include all isotopes decay corrected to a reference date of 1/1/2022. These factors may be considerations in criticality studies of the related 237 Np sphere.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Final Scientific/Technical Report: Simultaneous Lithium Extraction and Thin-Film Deposition of Lithium Metal for Low-Cost, High-Energy Anodes from Brine Resources

This report describes the scale-up and pilot validation of Alpha-En's Reductive Lithium Extraction (RLE) process, which directly converts lithium ions from aqueous brine-derived feedstocks into thin-film lithium metal anodes, demonstrating greater than 50% extraction efficiency, battery performance matching or exceeding commercial lithium metal controls in coin and pouch cells, and continuous roll-to-roll production of a meter-scale lithium metal anode strip.

25 ENERGY STORAGE↗

Omics-Lethal Human Viruses, Interferon-Stimulated Response Experiment IFNaCL001

The purpose of this experiment was to evaluate the host interferon-stimulated cellular response to interferon alpha (IFNα) treatment. Sample data was obtained from human lung adenocarcinoma cells (Calu-3) treated with or without IFNα for mRNA and miRNA transcriptome expression analysis. Secondary host-associated viral dataset downloads contain one or more statistically processed (normalization data transformation) quantitative dataset collections resulting in qualitative expression analyses of primary host-pathogen experimental study designs. Transcriptomics dataset download have a direct relationship to a primary sample submission corresponding to a specific interferon response to viral infection.

59 BASIC BIOLOGICAL SCIENCES↗

Omics-Lethal Human Viruses, Interferon-Stimulated Response Experiment IFNaIHH001

The purpose of this experiment was to evaluate the host interferon-stimulated cellular response to interferon alpha (IFNα) treatment. Sample data was obtained from human immortalized human hepatocyte cells (IHH) treated with or without IFNα for mRNA and miRNA transcriptome expression analysis.

59 BASIC BIOLOGICAL SCIENCES↗