Search NASA⌕ Search

SEARCH · Search NASA

Results for “Advanced Instrumentation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

BORE II

Bore II, co-developed by Berkeley Lab researchers Frank Hale, Chin-Fu Tsang, and Christine Doughty, provides vital information for solving water quality and supply problems and for improving remediation of contaminated sites. Termed "hydrophysical logging," this technology is based on the concept of measuring repeated depth profiles of fluid electric conductivity in a borehole that is pumping. As fluid enters the wellbore, its distinct electric conductivity causes peaks in the conductivity log that grow and migrate upward with time. Analysis of the evolution of the peaks enables characterization of groundwater flow distribution more quickly, more cost effectively, and with higher resolution than ever before. Combining the unique interpretation software Bore II with advanced downhole instrumentation (the hydrophysical logging tool), the method quantifies inflow and outflow locations, their associated flow rates, and the basic water quality parameters of the associated formation waters (e.g., pH, oxidation-reduction potential, temperature). In addition, when applied in conjunction with downhole fluid sampling, Bore II makes possible a complete assessment of contaminant concentration within groundwater.

Source record↗

Dark Matter Hunt with LUX-ZEPLIN (LZ)

SLAC is helping to build and test the LUX-ZEPLIN or LZ detector, one of the biggest and most sensitive detectors ever designed to catch hypothetical dark matter particles known as WIMPs. Researchers at the Department of Energy’s SLAC National Accelerator Laboratory are on a quest to solve one of physics’ biggest mysteries: What exactly is dark matter – the invisible substance that accounts for 85 percent of all the matter in the universe but can’t be seen even with our most advanced scientific instruments? Most scientists believe it’s made of ghostly particles that rarely bump into their surroundings; that’s why billions of dark matter particles might zip right through our bodies every second without us even noticing. Leading candidates for dark matter particles are WIMPs, or weakly interacting massive particles. Now SLAC is helping to build and test one of the biggest and most sensitive detectors ever designed to catch a WIMP – the LUX-ZEPLIN or LZ detector.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Monitoring and Control of the Hybrid Laser-Gas Metal-Arc Welding Process

Methods are currently being developed towards a more robust system real time feedback in the high throughput process combining laser welding with gas metal arc welding. A combination of ultrasonic, eddy current, electronic monitoring, and visual techniques are being applied to the welding process. Initial simulation and bench top evaluation of proposed real time techniques on weld samples are presented along with the concepts to apply the techniques concurrently to the weld process. Consideration for the eventual code acceptance of the methods and system are also being researched as a component of this project. The goal is to detect defects or precursors to defects and correct when possible during the weld process.

36 MATERIALS SCIENCE↗

A Guide for Selecting Appropriate Human Factors Methods and Measures in Control Room Modernization Efforts in Nuclear Power Plants

Abstract. Many of the U.S. nuclear power plants are approaching the end of their 60-year licensing period. The U.S. Department of Energy Light Water Reactor Sustainability Program is conducting targeted research to extend the lives and ensure long-term reliability, productivity, safety, and security of these plants through targeted research, such as with integrating advanced digital instrumentation and control technologies in the main control room. There are many challenges to this, one being the integration of human factors engineering in the design and evaluation of these upgrades. This paper builds upon recent efforts in developing utility-specific guidance for integrating human factors engineering in the control room modernization process by providing commonly used data collection methods that are applicable at various phases of the upgrade process. Advantages and disadvantages of each method is provided for consideration of an optimal human factors evaluation plan to be used throughout the lifespan of the upgrade process.

99 GENERAL AND MISCELLANEOUS↗

Axion Dark Matter

Axions are well-motivated dark matter candidates with simple cosmological production mechanisms. They were originally introduced to solve the strong CP problem, but also arise in a wide range of extensions to the Standard Model. This Snowmass white paper summarizes axion phenomenology and outlines next-generation laboratory experiments proposed to detect axion dark matter. There are vibrant synergies with astrophysical searches and advances in instrumentation including quantum-enabled readout, high-Q resonators and cavities and large high-field magnets. This white paper outlines a clear roadmap to discovery, and shows that the US is well-positioned to be at the forefront of the search for axion dark matter in the coming decade.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Experimental Approaches for Solution X-Ray Scattering And Fiber Diffraction

X-ray scattering and diffraction from non-crystalline systems have gained renewed interest in recent years, as focus shifts from the structural chemistry information gained by high-resolution studies to the context of structural physiology at larger length scales. Such techniques permit the study of isolated macromolecules as well as highly organized macromolecular assemblies as a whole under near-physiological conditions. Time-resolved approaches, made possible by advanced synchrotron instrumentation, add a crucial dimension to many of these investigations. This article reviews experimental approaches in non-crystalline X-ray scattering and diffraction that may be used to illuminate important scientific questions such as protein/nucleic acid folding and structure-function relationships in large macromolecular assemblies.

43 PARTICLE ACCELERATORS↗

The ISRU Field Tests 2010 and 2012 at Mauna Kea, Hawaii: Results from the Miniaturised Mossbauer Spectrometers Mimos II and Mimos IIA

The 2010 and 2012 In-Situ Resource Utilization Analogue Test (ISRU) [1] on the Mauna Kea volcano in Hawai'i was coordinated by the Northern Centre for Advanced Technology (NORCAT) in collaboration with the Canadian Space Agency (CSA), the German Aerospace Center (DLR), and the National Aeronautics and Space Administration (NASA), through the PISCES program. Several instruments were tested as reference candidates for future analogue testing at the new field test site at the Mauna Kea volcano in Hawai'i. The fine-grained, volcanic nature of the material is a suitable lunar and martian analogue, and can be used to test excavation, site preparation, and resource utilization techniques. The 2010 location Pu'u Hiwahine, a cinder cone located below the summit of Mauna Kea (19deg45'39.29" N, 155deg28'14.56" W) at an elevation of ~2800 m, provides a large number of slopes, rock avalanches, etc. to perform mobility tests, site preparation or resource prospecting. Besides hardware testing of technologies and systems related to resource identification, also in situ science measurements played a significant role in integration of ISRU and science instruments. For the advanced Mössbauer instrument MIMOS IIA, the new detector technologies and electronic components increase sensitivity and performance significantly. In combination with the high energy resolution of the SDD it is possible to perform Xray fluorescence analysis simultaneously to Mössbauer spectroscopy. In addition to the Fe-mineralogy, information on the sample's elemental composition will be gathered. The 2010 and 2012 field campaigns demonstrated that in-situ Mössbauer spectroscopy is an effective tool for both science and feedstock exploration and process monitoring. Engineering tests showed that a compact nickel metal hydride battery provided sufficient power for over 12 hr of continuous operation for the MIMOS instruments.

Klingelhoefer, G.↗

International comparative study of systems for the government advancement of research and development

The reorganization, structure and instruments of government advancement of research in three countries was compared: France, Sweden and the USA. In France the powers are centralized; in Sweden and the USA, decentralized. Assistance to projects is provided with grants and contracts in all three countries. France and Sweden also give loans with conditional waiving of reimbursement in case of failure. In all three countries indirect assistance is provided only with small tax breaks.

Ripke, M.↗

Radiation-Hardened GaN HEMT and Cell Design, Modeling, and Fabrication for Nuclear Instrumentation Applications

Recent advances in nuclear power generation technologies show great promise for efficient, safe generation of carbon-free power in the near future. Consequently, many new generation reactor designs are being pursued by government and industry groups, including both fission- and fusion-based technologies. Radiation- and temperature-tolerant sensor technology continues to advance, yet development of the electronics/instrumentation technologies suitable for these environments have fallen behind. Industry has adequately addressed harsh environment electronics needs for low earth orbit satellites, but the much more extreme conditions associated with electronics placed near or in a reactor core remain unaddressed. This project investigates the use of gallium nitride (GaN) circuit technology to address the unique needs for sensor interface electronics and communications in reactor environments. This report provides a summary of the first year’s project activities related to developing and optimizing devices and circuits for this GaN high electronic mobility transistor (HEMT) process. Activities reported include multiple analog and digital circuit designs simulated using custom Verilog-A models generated from measured GaN devices fabricated in the target process. Digital circuit designs included fundamental logic circuits such as an inverter, NAND, NOR, AND and OR gates, as well as a 5-stage ring oscillator. Each design was simulated using an open-source SPICE simulator, and an integrated circuit layout was produced of each design for use in future fabrication. Analog circuit designs focused on the fundamental building blocks to be used to construct sensor interface and communications circuits. These included current mirrors, matched differential pairs, and a Gilbert cell mixer design, each with an associated integrated circuit layout. Layout tools used for these designs included two open-source packages—KLayout and Magic—which were customized for specific use with the OSU GaN process layers. Design rules and preliminary device extraction capabilities were built for the Magic tool to enable device extraction and subsequent netlist generation for SPICE simulation. Finally, future research directions for year two are summarized. When the year-two directions are implemented, the project will be in position to advance the state of the art in electronics for near- or in-reactor sensor interfacing and communications.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

AXAF, a permanent orbiting X-ray observatory - Telescope and instrumentation plans

The Advanced X-ray Astrophysics Facility (AXAF) now under study is to be a long-lived X-ray observatory in space. It is to be launched by the Space Shuttle, maintainable on-orbit, and retrievable for ground re-furbishment. The AXAF is conceived as an X-ray telescope with 6 nested grazing incidence X-ray mirrors (with a maximum aperture of 1.2 m) and interchangeable and replaceable focal plane instruments. The optics will provide 0.5 arcsecond imagery over a several arcminute field and somewhat reduced resolution over 1 degree in the X-ray band from 0.1 to 10 keV (1.2 to 120 A). The characteristics and expected performance of the observatory are described.

Zombeck, M. V.↗

AXAF, a permanent orbiting X-ray observatory - Telescope and instrumentation plans

The Advanced X-ray Astrophysics Facility (AXAF) now under study is to be a long-lived X-ray observatory in space. It is to be launched by the Space Shuttle, maintainable on-orbit, and retrievable for ground re-furbishment. The AXAF is conceived as an X-ray telescope with 6 nested grazing incidence X-ray mirrors (with a maximum aperture of 1.2 microns) and interchangeable and repleceable focal plane instruments. The optics will provide 0.5 arcsecond imagery over a several arcminute field and somewhat reduced resolution over 1 degree in the X-ray band from 0.1 to 10 keV (1.2 to 120 A). The characteristics and expected performance of the observatory are described.

Zombeck, M. V.↗

eVTOL Vehicle-Agnostic Instrument Flight Procedures Test Plan

NASA Advanced Air Mobility National Campaign is researching the utility of electric vertical takeoff and land (eVTOL) advanced air mobility (AAM) instrument flight procedures. The result will be dynamic and tailored procedures that align to the following modus operandi: maximize safety, optimize efficiency, support passenger comfort and minimize acoustics. This is achieved through dynamic airspace procedure design, which is a modular approach to create an airspace construct that customizes procedures to vehicle design and configuration, operation and environmental conditions. The test plan supports different eVTOL platforms and envisioned operations for flight test or simulation and may be leveraged by AAM aircraft manufacturers and operators for any given aircraft, location and operation.

eVTOL test plan↗

Assessment of ASI-developed Sensors for Inclusion in METL Testing

The Advanced Sensors and Instrumentation (ASI) program facilitates the development of new sensors for both conventional and advanced reactors. Advanced reactor concepts utilize coolants other than light water, such as molten salts, liquid sodium, and high-temperature helium. Qualification of sensors developed for these advanced reactors is complicated by the relatively small number of facilities available that can provide relevant testing conditions (e.g., temperature, flow, and coolant chemistry). This report identifies sensors that were developed under the ASI program and may be tested in one available testbed: the Mechanisms Engineering Test Loop (METL) at Argonne National Laboratory (ANL), a non-nuclear liquid sodium flow facility.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Critical Evaluation of 0-30 km Profile Information in Ground-Based Zenith-Sky and Satellite-Measured Backscattered UV Radiation

We now have several decades of experience in deriving vertical ozone profiles from the measurements of diffuse ultraviolet radiation by both ground and satellite-based instruments using Umkehr and BUV techniques. Continuing technological advances are pushing the state-of-the-art of these measurements to high spectral resolution and broader wavelength coverage. These modern instruments include the ground-based Brewer and satellite-based Global Ozone Monitoring Experiment (GOME) instruments, as well as advanced instruments being developed by ESA(SCIAMACHY), Netherlands(OMI) and Japan(ODUS). However, one of the issues that remains unresolved is the 0-30 km ozone profile information retrievable from these measurements. Though it is commonly believed that both the Umkehr and the satellite-based BUV techniques have very limited profile information below 30 km, there are those who argue that the data from these instruments should continue to be reported in this altitude range for they compare well with ozonesondes and hence there is useful scientific information. Others claim that the limitations of the Umkehr and BUV techniques are largely due to their low spectral resolution, and that the profile information below 30 km can be greatly improved by going to high spectral resolution instruments, such as Brewer and GOME. The purpose of this paper is to provide a critical evaluation of the 0-30 km ozone profile information in the various UV remote sensing techniques. We use a database of individual ozone profiles created using ozonesondes and SAGE and 4D ozone fields generated by data assimilation techniques to simulate radiances measured by the various techniques. We then apply a common inversion approach to all the methods to systematically examine how much profile information is available simply from the knowledge of total ozone, how much additional profile information is added by the traditional Dobson Umkehr and satellite buv techniques, and how much better one can do by adding additional wavelengths and by going to higher spectral resolution. An open and honest discussion of these issues is critical to provide the ozone science community a realistic assessment of the quality of data in the lower stratosphere and troposphere expected from both past and future instruments.

Bhartia, Pawan↗

An Overview of Argonne’s Advanced Mobility Technology Laboratory Vehicle Systems Instrumentation and Evaluation Methodology

This report will provide a general overview of the testing facilities, research equipment, and general testing methodologies Argonne utilizes to conduct vehicle technology evaluations of advanced technology research vehicles. Data is captured from vehicle evaluations that provide powertrain operation and corresponding energy consumption based on a combination of in-depth instrumentation and focused testing. This resulting dataset of hundreds of time-resolved vehicle signals provide a basis for direct analysis and model validation of vehicle specific technologies. Argonne has attempted to standardize the approach to vehicle instrumentation and testing at Argonne, but it should be noted that each vehicle, and the corresponding assessment, remains unique. It is suggested that the reader reference vehicle specific testing reports for an overview of the unique aspects for each test vehicle. Additionally, the datasets for research vehicles are made publicly available through the Advanced Mobility Technology Laboratory’s Downloadable Driving Database (D3) at www.anl.gov/d3.

33 ADVANCED PROPULSION SYSTEMS↗

Employee Spotlight: Karena Chapman

A spotlight on Argonne National Laboratory's employee, Karena Chapman, who works as a chemist in the X-ray Science Division on running instruments at the Advanced Photon Source.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cold Spray Cobalt Magnetostrictive Electromagnetic Acoustic Transducers for High Temperature Structure Monitoring

The Department of Energy’s Advanced Sensors and Instrumentation program seeks to develop and qualify advanced sensors for the nuclear industry. Reliable high temperature and high radiation sensors for detection and characterization of structural flaws in pipes, vessels, and structurally critical components is a weakness for both conventional light water reactors with coolant T-hot approaching 350oC, and for advanced reactors with T-hot temperatures in excess of 500 to 800oC. Magnetostrictive Electromagnetic Acoustic Transducers using a cold spray cobalt coating have been proposed as a sensor design that can withstand these kinds of temperatures and radiation levels to serve as online sensors to detect flaws before cracks, pits, or erosion/corrosion flaws progress to through-wall failures. This report tests cold spray cobalt as part of a magnetostrictive EMAT for high temperature service. Cobalt is known to have strong magnetostrictive properties however the effect of cold spray application is not well studied. This program was surprised to discover that cold sprayed cobalt exhibited little or no magnetostrictive behavior until it was thermally annealed. Following annealing to 650oC however, cold spray cobalt did exhibit a magnetostrictive response. Work to date prior to this milestone report publication showed that magnetostrictive EMAT was successfully tested to 400oC with an alnico permanent magnet. The program plans to extend testing with an electromagnet to higher temperatures. This follow-on work will be reported under subsequent publications or as a revision to this report.

Glass, Samuel W.↗