Search NASA⌕ Search

SEARCH · Search NASA

Results for “Angular dependence”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Imaging the molecular dynamics of dissociative electron attachment to water

Momentum imaging experiments on dissociative electron attachment to the water molecule are combined with ab initio theoretical calculations of the angular dependence of the quantum mechanical amplitude for electron attachment to provide a detailed picture of the molecular dynamics of dissociation attachment via the two lowest energy Feshbach resonances. The combination of momentum imaging experiments and theory can reveal dissociation dynamics for which the axial recoil approximation breaks down and thus provides a powerful reaction microscope for DEA to polyatomics.

74 ATOMIC AND MOLECULAR PHYSICS↗

Magnetic Damping Modulation in IrMn 3 / Ni 80 Fe 20 via the Magnetic Spin Hall Effect

Noncollinear antiferromagnets can have additional spin Hall effects due to the net chirality of their magnetic spin structure, which provides for more complex spin-transport phenomena compared to ordinary nonmagnetic materials. Here we investigated how ferromagnetic resonance of permalloy (Ni 80 Fe 20 ) is modulated by spin Hall effects in adjacent epitaxial IrMn 3 films. We observe a large dc modulation of the ferromagnetic resonance linewidth for currents applied along the [001] IrMn 3 direction. Furthermore, this very strong angular dependence of spin-orbit torques from dc currents through the bilayers can be explained by the magnetic spin Hall effect where IrMn 3 provides novel pathways for modulating magnetization dynamics electrically.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Signatures of Multiband Effects in High-Harmonic Generation in Monolayer MoS 2

High-harmonic generation (HHG) in solids has been touted as a way to probe ultrafast dynamics and crystal symmetries in condensed matter systems. Here, we investigate the polarization properties of high-order harmonics generated in monolayer MoS 2 , as a function of crystal orientation relative to the mid-infrared laser field polarization. At several different laser wavelengths we experimentally observe a prominent angular shift of the parallel-polarized odd harmonics for energies above approximately 3.5 eV, and our calculations indicate that this shift originates in subtle differences in the recombination dipole strengths involving multiple conduction bands. Further, this observation is material specific and is in addition to the angular dependence imposed by the dynamical symmetry properties of the crystal interacting with the laser field, and may pave the way for probing the vectorial character of multiband recombination dipoles.

2-dimensional systems↗

Enhancement of Rydberg Blockade via Microwave Dressing

Experimental control over the strength and angular dependence of interactions between atoms is a key capability for advancing quantum technologies. Here, in this work, we use microwave dressing to manipulate and enhance Rydberg-Rydberg interactions in an atomic ensemble. By varying the cloud length relative to the blockade radius and measuring the statistics of the light retrieved from the ensemble, we demonstrate a clear enhancement of the interaction strength due to microwave dressing. These results are successfully captured by a theoretical model that accounts for the excitation dynamics, atomic density distribution, and phase-matched retrieval efficiency. Our approach offers a versatile platform for further engineering interactions by exploiting additional features of the microwave fields, such as polarization and detuning, opening pathways for new quantum control strategies.

collective effects in quantum optics↗

First-principles calculation of spin-orbit torque in a Co/Pt bilayer

The angular dependence of spin-orbit torque in a disordered Co/Pt bilayer is calculated using a first-principles nonequilibrium Green's function formalism with an explicit supercell averaging over Anderson disorder. In addition to the usual dampinglike and fieldlike terms, the odd torque contains a sizable planar Hall-like term (m∙E)m × (z × m) whose contribution to current-induced damping is consistent with experimental observations. The dampinglike and planar Hall-like torquances depend weakly on disorder strength, while the fieldlike torquance declines with increasing disorder. The torques that contribute to damping are almost entirely due to spin-orbit coupling on the Pt atoms, but the fieldlike torque does not require it.

36 MATERIALS SCIENCE↗

Giant anisotropic magnetoresistance in oxygen-vacancy-ordered epitaxial La 0.5 Sr 0.5 CoO 3–δ films

Recent advances in complex oxide heterostructures have realized extraordinary control over oxygen vacancies ($V_\text{O}$), including strain-tuned $V_\text{O}$ order, and electric-field-controlled transformations between perovskite and $V_\text{O}$-ordered structures. Perovskite cobaltites such as La 1– x Sr x CoO 3–δ provide a prime example, recent work demonstrating that strain engineering of $V_\text{O}$ ordering induces large (~10 7 erg/cm 3 ) perpendicular magnetic anisotropy. Here we show that $V_\text{O}$-ordered epitaxial La 0.5 Sr 0.5 CoO 3–δ films exhibit not only strong magnetic anisotropy, but also a giant form of anisotropic magnetoresistance (AMR). This has magnetic field, temperature, and angular dependencies in quantitative accord with conventional AMR, but with AMR ratios up to an extraordinary 40.3%, 20 times enhanced over bulk cobaltites, and ~10–100 times larger than typical transition metals. This giant AMR has no strong dependence on heteroepitaxial strain (between –2.1% and +1.8%) or thickness, and is instead ascribed to symmetry lowering associated with $V_\text{O}$ ordering. The AMR ratios thus obtained in this work are among the largest reported in the over 160-year history of this phenomenon, despite the absence of heavy elements.

36 MATERIALS SCIENCE↗

Capping layer influence and isotropic in-plane upper critical field of the superconductivity at the FeSe / SrTiO 3 interface

Understanding the superconductivity at the interface of FeSe/SrTiO 3 is a problem of great contemporary interest due to the significant increase in critical temperature (T c ) compared to that of bulk FeSe, as well as the possibility of an unconventional pairing mechanism and topological superconductivity. We report a study of the influence of a capping layer on superconductivity in thin films of FeSe grown on SrTiO 3 using molecular beam epitaxy. We used in vacuo four-probe electrical resistance measurements and ex situ magnetotransport measurements to examine the effect of three capping layers that provide distinct charge transfer into FeSe: insulating FeTe, nonmetallic Te, and metallic Zr. Our results show that FeTe provides an optimal cap that barely influences the inherent T c found in pristine FeSe/SrTiO 3 , while the transfer of holes from a nonmetallic Te cap completely suppresses superconductivity and leads to insulating behavior. Finally, we used ex situ magnetoresistance measurements in FeTe capped FeSe films to extract the angular dependence of the in-plane upper critical magnetic field. Our observations reveal an almost isotropic in-plane upper critical field, providing insight into the symmetry and pairing mechanism of high-temperature superconductivity in FeSe.

36 MATERIALS SCIENCE↗

Two-Fold Reduction of J c Anisotropy in FeSe 0.5 Te 0.5 Films Using Low-Energy Proton Irradiation

High in-field performance and low anisotropy of critical current density J c are important for superconducting wires/tapes in rotating machine and magnet applications. Here, we report measurements of angular dependence of critical current density J c in pro-ton irradiated FeSe 0.5 Te 0.5 (FST) films at magnetic field up to 35 T. Here, we observed two-fold reduction in the J c anisotropy of FST films at 4.2 K and 15 Tesla magnetic field by irradiation with low-energy (190 keV) proton. In light of recent demonstration of roll-to-roll irradiation process successfully incorporated in the standard 2G HTS long length production wire, low-energy proton irradiation can be a practical solution to enhance the performance of iron-based super-conducting wires and tapes, as low-energy ion sources are inexpensive to operate and are readily available commercially.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Hardness assurance for proton direct ionization-induced SEEs using a high-energy proton beam

The low-energy proton energy spectra of all shielded space environments have the same shape. This shape is easily reproduced in the laboratory by degrading a high-energy proton beam, producing a high-fidelity test environment. We use this test environment to dramatically simplify rate prediction for proton direct ionization effects, allowing the work to be done at high-energy proton facilities, on encapsulated parts, without knowledge of the IC design, and with little or no computer simulations required. Proton direct ionization (PDI) is predicted to significantly contribute to the total error rate under the conditions investigated. Scaling effects are discussed using data from 65-nm, 45-nm, and 32-nm SOI SRAMs. These data also show that grazing-angle protons will dominate the PDI-induced error rate due to their higher effective LET, so PDI hardness assurance methods must account for angular effects to be conservative. As a result, we show that this angular dependence can be exploited to quickly assess whether an IC is susceptible to PDI.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Reflectance of Silicon Photomultipliers at Vacuum Ultraviolet Wavelengths

Characterization of the vacuum ultraviolet (VUV) reflectance of silicon photomultipliers (SiPMs) is important for large-scale SiPM-based photodetector systems. In this work, we report the angular dependence of the specular reflectance in vacuum of SiPMs manufactured by Fondazionc Bruno Kessler (FBK) and Hamamatsu Photonics K.K. (HPK) over wavelengths ranging from 120 to 280 nm. Refractive index and extinction coefficient of the thin silicon-dioxide film deposited on the surface of the FBK SiPMs are derived from reflectance data of an FBK silicon wafer with the same deposited oxide film as SiPMs. The diffuse reflectance of SiPMs is also measured at 193 nm. We use the VUV spectral dependence of the optical constants to predict the reflectance of the FBK silicon wafer and FBK SiPMs in liquid xenon.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Characterization of a water-equivalent fiber-optic coupled dosimeter for use in diagnostic radiology

This work reports on the characterization of a new fiber-optic coupled (FOC) dosimeter for use in the diagnostic radiology energy range. The FOC dosimeter was constructed by coupling a small cylindrical plastic scintillator, 500 {mu}m in diameter and 2 mm in length, to a 2 m long optical fiber, which acts as a light guide to transmit scintillation photons from the sensitive element to a photomultiplier tube (PMT). A serial port interface on the PMT permits real-time monitoring of light output from the dosimeter via a custom computer program. The FOC dosimeter offered excellent sensitivity and reproducibility, allowing doses as low as 0.16 mGy to be measured with a coefficient of variation of only 3.64%. Dose linearity was also excellent with a correlation coefficient of 1.000 over exposures ranging from 0.16 to 57.29 mGy. The FOC dosimeter exhibited little angular dependence from axial irradiation, varying by less than 5% over an entire revolution. A positive energy dependence was observed and measurements performed within a scatter medium yielded a 10% variation in sensitivity as beam quality changed due to hardening and scatter across a 16 cm depth range. The current dosimetry system features an array of five PMTs to allow multiple FOC dosimeters to be monitored simultaneously. Overall, the system allows for rapid and accurate dose measurements relevant to a range of diagnostic imaging applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Computed tomography dose measurements with radiochromic films and a flatbed scanner

Gafchromic XR-QA films were developed for patient dosimetry in diagnostic radiology. A possible application of these films is the measurement of doses in computed tomography. In this study a method to evaluate the CTDI using Gafchromic XR-QA film and a flatbed scanner was developed and tested. Film samples were cut to dimensions of 6x170 mm{sup 2} in order to have an integration area similar to that of a pencil ionization chamber, with the possibility of changing the integration length. Prior to exposing these films to a computed tomography beam, the angular dependence of the film dose response was investigated by exposing film strips to a static x-ray beam at different angles in the range 0 deg. - 180 deg. A difference of 49% was found between the response with the axis beam parallel to the film surface (90 deg.) and with the axis beam perpendicular (0 deg. and 180 deg.). Integrating over a 360 deg. exposure like the one in computed tomography, a difference of less than 2% was estimated, which is comparable with the measurement error obtainable with XR-QA film. A calibration with a CT beam in the scout mode was performed and film strips were then exposed to single axial scans and to helical scans both in air and in phantoms. Two different types of flatbed scanners were used to read the film samples, a Microtek ScanMaker 9800XL scanner and an Epson Expression 10000 XL scanner, and the accuracy of the results were compared. For beam collimations above 10 mm differences between CTDI measured by film and CTDI measured by ionization chamber below 9% were found for the Epson scanner, with an average estimated error at 1 {sigma} level of 5%. For the Microtek scanner and for the same film samples, differences below 11% with an average error at 1 {sigma} level of 8% were founded. The 1 {sigma} uncertainty of the measured CTDI was provided by the method for each measurement, and it was shown that about the 95% of the differences between the CTDI measurements with radiochromic films and with the ionization chamber were below the estimated 2 {sigma} uncertainty, for both scanners. After an accurate calibration procedure and the consideration of the uncertainty associated with the measurement, Gafchromic XR-QA films can be used to evaluate the CTDI.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Study of the response of plastic scintillation detectors in small-field 6 MV photon beams by Monte Carlo simulations

Purpose: To investigate the response of plastic scintillation detectors (PSDs) in a 6 MV photon beam of various field sizes using Monte Carlo simulations. Methods: Three PSDs were simulated: A BC-400 and a BCF-12, each attached to a plastic-core optical fiber, and a BC-400 attached to an air-core optical fiber. PSD response was calculated as the detector dose per unit water dose for field sizes ranging from 10x10 down to 0.5x0.5 cm{sup 2} for both perpendicular and parallel orientations of the detectors to an incident beam. Similar calculations were performed for a CC01 compact chamber. The off-axis dose profiles were calculated in the 0.5x0.5 cm{sup 2} photon beam and were compared to the dose profile calculated for the CC01 chamber and that calculated in water without any detector. The angular dependence of the PSDs' responses in a small photon beam was studied. Results: In the perpendicular orientation, the response of the BCF-12 PSD varied by only 0.5% as the field size decreased from 10x10 to 0.5x0.5 cm{sup 2}, while the response of BC-400 PSD attached to a plastic-core fiber varied by more than 3% at the smallest field size because of its longer sensitive region. In the parallel orientation, the response of both PSDs attached to a plastic-core fiber varied by less than 0.4% for the same range of field sizes. For the PSD attached to an air-core fiber, the response varied, at most, by 2% for both orientations. Conclusions: The responses of all the PSDs investigated in this work can have a variation of only 1%-2% irrespective of field size and orientation of the detector if the length of the sensitive region is not more than 2 mm long and the optical fiber stems are prevented from pointing directly to the incident source.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A feasibility study of using couch-based real time dosimetric device in external beam radiotherapy

Purpose: Measurement of actual dose delivered during radiotherapy treatment aids in checking the accuracy of dose delivered to the patient. In this study, a couch-based real time dosimetric device has been proposed to measure the exit or entrance dose to a patient during external beam radiotherapy. The utility and feasibility of such a device using a 2D array of diodes has been demonstrated. Methods: Two MAPCHECK devices: MAPCHECK (1175) and MAPCHECK 2 (both SunNuclear) were embedded in a foam block in the treatment couch of a Varian 21iX linear accelerator. The angular dependence of the detector response for both devices was studied before implementing the MAPCHECKs for experimental purposes. An Alderson Rando head phantom was scanned with the MAPCHECK and MAPCHECK 2 devices separately and four different treatment plans were generated with target volumes at three different positions simulating typical clinical situations. The analytical anisotropic algorithm (AAA) was used to compute the doses in an Eclipse treatment planning system (Varian Medical Systems). The Rando phantom with the MAPCHECK device was exposed in Clinac 21iX linear accelerator. The measured dose distribution was compared with the calculated dose distribution to check for the accuracy in dose delivery. Results: Measured and computed dose distribution were found to agree with more than 93% of pixels passing at 3% and 3 mm gamma criteria for all the treatment plans. The couch-based real time dosimetry system may also be applied for noncoplanar beams where electronic portal imaging device (EPID) is not practical to measure the dose. Other advantages include checking the beam stability during the patient treatment, performing routine morning quality assurance (QA) tests in the linear accelerator, and to perform pretreatment verification of intensity modulated radiation therapy (IMRT). One of the drawbacks of this system is that it cannot be used for measuring the dose at 90 deg. or 270 deg. gantry angles. Conclusions: This preliminary study shows that a 2D array of detectors may be used as part of the treatment couch for real time patient dosimetry in studying the dose delivered to the patient in real time and also for performing routine quality assurance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dosimetric performance and array assessment of plastic scintillation detectors for stereotactic radiosurgery quality assurance

Purpose: To compare the performance of plastic scintillation detectors (PSD) for quality assurance (QA) in stereotactic radiosurgery conditions to a microion-chamber (IC), Gafchromic EBT2 films, 60 008 shielded photon diode (SD) and unshielded diodes (UD), and assess a new 2D crosshair array prototype adapted to small field dosimetry. Methods: The PSD consists of a 1 mm diameter by 1 mm long scintillating fiber (BCF-60, Saint-Gobain, Inc.) coupled to a polymethyl-methacrylate optical fiber (Eska premier, Mitsubishi Rayon Co., Ltd., Tokyo, Japan). Output factors (S{sub c,p}) for apertures used in radiosurgery ranging from 4 to 40 mm in diameter have been measured. The PSD crosshair array (PSDCA) is a water equivalent device made up of 49 PSDs contained in a 1.63 cm radius area. Dose profiles measurements were taken for radiosurgery fields using the PSDCA and were compared to other dosimeters. Moreover, a typical stereotactic radiosurgery treatment using four noncoplanar arcs was delivered on a spherical phantom in which UD, IC, or PSD was placed. Using the Xknife planning system (Integra Radionics Burlington, MA), 15 Gy was prescribed at the isocenter, where each detector was positioned. Results: Output Factors measured by the PSD have a mean difference of 1.3% with Gafchromic EBT2 when normalized to a 10 x 10 cm{sup 2} field, and 1.0% when compared with UD measurements normalized to the 35 mm diameter cone. Dose profiles taken with the PSD crosshair array agreed with other single detectors dose profiles in spite of the presence of the 49 PSDs. Gamma values comparing 1D dose profiles obtained with PSD crosshair array with Gafchromic EBT2 and UD measured profiles shows 98.3% and 100.0%, respectively, of detector passing the gamma acceptance criteria of 0.3 mm and 2%. The dose measured by the PSD for a complete stereotactic radiosurgery treatment is comparable to the planned dose corrected for its SD-based S{sub c,p} within 1.4% and 0.7% for 5 and 35 mm diameter cone, respectively. Furthermore, volume averaging of the IC can be observed for the 5 mm aperture where it differs by as much as 9.1% compared to the PSD measurement. The angular dependency of the UD is also observed, unveiled by an under-response around 2.5% of both 5 and 35 mm apertures. Conclusions: Output Factors and dose profiles measurements performed, respectively, with the PSD and the PSDCA were in agreement with those obtained with the UD and EBT2 films. For stereotactic radiosurgery treatment verification, the PSD gives accurate results compared to the planning system and the IC once the latter is corrected to compensate for the averaging effect of the IC. The PSD provides precise results when used as a single detector or in a dense array, resulting in a great potential for stereotactic radiosurgery QA measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Projection imaging of photon beams by the Cerenkov effect

Purpose: A novel technique for beam profiling of megavoltage photon beams was investigated for the first time by capturing images of the induced Cerenkov emission in water, as a potential surrogate for the imparted dose in irradiated media. Methods: A high-sensitivity, intensified CCD camera (ICCD) was configured to acquire 2D projection images of Cerenkov emission from a 4 Multiplication-Sign 4 cm{sup 2} 6 MV linear accelerator (LINAC) x-ray photon beam operating at a dose rate of 400 MU/min incident on a water tank with transparent walls. The ICCD acquisition was gated to the LINAC sync pulse to reduce background light artifacts, and the measurement quality was investigated by evaluating the signal to noise ratio and measurement repeatability as a function of delivered dose. Monte Carlo simulations were used to derive a calibration factor for differences between the optical images and deposited dose arising from the anisotropic angular dependence of Cerenkov emission. Finally, Cerenkov-based beam profiles were compared to a percent depth dose (PDD) and lateral dose profile at a depth of d{sub max} from a reference dose distribution generated from the clinical Varian ECLIPSE treatment planning system (TPS). Results: The signal to noise ratio was found to be 20 at a delivered dose of 66.6 cGy, and proportional to the square root of the delivered dose as expected from Poisson photon counting statistics. A 2.1% mean standard deviation and 5.6% maximum variation in successive measurements were observed, and the Monte Carlo derived calibration factor resulted in Cerenkov emission images which were directly correlated to deposited dose, with some spatial issues. The dose difference between the TPS and PDD predicted by Cerenkov measurements was within 20% in the buildup region with a distance to agreement (DTA) of 1.5-2 mm and {+-}3% at depths beyond d{sub max}. In the lateral profile, the dose difference at the beam penumbra was within {+-}13% with a DTA of 0-2 mm, {+-}5% in the central beam region, and 2%-3% in the beam umbra. Conclusions: The results from this initial study demonstrate the first documented use of Cerenkov emission imaging to profile x-ray photon LINAC beams in water. The proposed modality has several potential advantages over alternative methods, and upon future refinement may prove to be a robust and novel dosimetry method.

61 RADIATION PROTECTION AND DOSIMETRY↗