Search NASA⌕ Search

SEARCH · Search NASA

Results for “Automation & Control Systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

From natural language to control signals: a conceptual framework for semantic channel finding in complex experimental infrastructure

Modern experimental platforms such as particle accelerators, fusion devices, telescopes, and industrial process control systems expose tens to hundreds of thousands of control and diagnostic channels, accumulated over decades of hardware evolution. Operators and AI systems alike depend on informal expert knowledge, inconsistent naming conventions, and scattered documentation to locate the signals required for monitoring, troubleshooting, and automated control, creating a persistent bottleneck for reliability, scalability, and emerging language-model-driven interfaces. We formalize semantic channel finding, the task of mapping natural-language intent to concrete control-system signals, as a general problem in complex experimental infrastructure, and introduce a four-paradigm conceptual framework to guide architecture selection based on facility-specific data regimes. The paradigms span (i) direct in-context lookup over small, curated channel dictionaries, (ii) constrained hierarchical navigation through structured trees, (iii) interactive agent exploration using iterative reasoning and tool-based database queries, and (iv) ontology-grounded semantic search that decouples channel meaning from facility-specific naming conventions. We demonstrate the practical feasibility of each paradigm through proof-of-concept implementations at four operational facilities spanning two orders of magnitude in scale: from compact free-electron lasers to large synchrotron light sources, operating under diverse control-system architectures ranging from clean hierarchical naming schemes to legacy environments with decades of heterogeneous conventions. Where evaluated against expert-curated operational queries, these instantiations achieve 90%–97% accuracy, validating the framework’s applicability across real-world deployment scenarios. To accelerate adoption across the broader scientific and industrial control-system community, we release open-source, plug-and-play implementations of all three interactive paradigms-direct lookup, hierarchical navigation, and middle-layer exploration-within the Osprey framework, together with tools for channel database generation, interactive testing, and minimal-configuration deployment. This work establishes semantic channel finding as a foundational capability for human-centric and agentic AI interfaces at large-scale facilities, providing both a systematic framework for architecture design and practical resources to enable adoption without building custom infrastructure from scratch.

channel finding↗

A New Layer to the PRA: Operational Performance Risk Assessment

A supervisory control system (SCS) concept developed by Oak Ridge National Laboratory provides automated risk-informed decision-making capabilities with the ultimate goal of significantly boosting plant availability while reducing dependency on human resources for multi-module advanced reactors. The decision-making process integrates online-monitoring systems, and the associated diagnostic and prognostics tools to continuously take into account the component health in an integrated probabilistic/deterministic meta model to capture the system behavior during a select set of postulated anticipated operational occurrence scenarios. The operational performance risk assessment (OPRA) approach is introduced to support SCS decisions probabilistically to minimize/prevent unnecessary trips and challenges to plant safety systems. OPRA identifies and ranks the success paths, combination of the non-safety systems and components, with the real-time failure data using event tree/fault tree method. OPRA does not interfere with the safety systems and adds a buffer zone to the existing probabilistic risk assessment (PRA) domain by minimizing the possible transients. In this work, failure scenarios of feedwater and turbine control valves are analyzed for ALMR PRISM (Power Reactor Innovative Small Module) design at full power. As an alternative to the default shutdown option, five and seven success paths (full and reduced power operation) are defined respectively within the OPRA framework.

Guler Yigitoglu, Askin↗

ARCADE Analysis Methods & Validation Pathway

The Advanced Reactor Cyber Analysis and Development Environment (ARCADE) provides an automated analysis system which supports risk-informed performance based (RIPB) evaluations of nuclear control systems. Every possible cyber threat which could lead to consequence is identified by simulating the unsafe control action sequences which transform digital harm into physical harm. Eliminating the simulation of complex digital cyber attack chains cuts out unnecessary computational overhead and focuses directly on the physics of cyber-physical attacks. This focus enables designers to make informed decisions which can entirely eliminate categories of cyber threats against advanced reactors through the physical nature of the plant design. This narrowing of cyber threat against nuclear power plants through the physics of the system is intended to make any remaining threat management and cost efficient. This is the goal of the Tiered Cyber Analysis (TCA) outlined in NRC Draft Regulation Guide (RG) 5.96, which provides a RIPB cybersecurity approach for new reactors. ARCADE has been custom developed to meet the demands of the rigorous analysis required in Tier 1 of the TCA, which forms the foundation of the TCA process. Currently, ARCADE is still under development, but has made significant leaps in capability. A pilot analysis on the opensource Asherah simulator was performed which demonstrated key functionality goals. The next stage of ARCADE development involves improvements to the applications which support the analysis system, and enabling the analysis system to utilize the full suite of unsafe control action simulations. Since the analysis method’s core functions are complete, validation of the analysis method will be started concurrent to the next development stages. The automated analysis ARCADE will provide can radically change the cybersecurity design process for advanced reactors, reducing the cost of security implementation while enhancing cyber resilience. The pathway for ARCADE’s development to this goal has become much clearer. The majority of technical hurdles have been cleared, and the remaining development needs have been solidified. ARCADE is now capable of assisting the advanced reactor design process and directly support advanced reactor industry RIPB practices.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Architectural Approaches for Integrating ADMS and DERMS: Challenges, Comparisons, and Real-World Use Cases

The electrical distribution landscape is rapidly transforming due to the proliferation of distributed energy resources (DERs) such as solar panels, wind turbines, battery storage systems, combined heat and power units, and electric vehicles, introducing variability and uncontrollability that traditional grid operators are ill-equipped to manage. This transformation is further accelerated by advancements in Information and Communication Technology infrastructure that connects control centers with end devices, demanding automation and a deeper understanding of new technologies by utility personnel. Advanced grid control techniques using system-level optimization, Artificial Intelligence, and Machine Learning at the enterprise level and distributed level are evolving to address these issues. There is also an opportunity to utilize the enormous data created by these new DER technologies in the grid. Advanced Distribution Management Systems (ADMS) and Distributed Energy Resource Management Systems (DERMS) are critical in addressing these challenges by automating grid operations and enhancing reliability. Given the relatively recent development of ADMS and DERMS, and the still relatively low level of ADMS and DERMS deployment in the industry, there is a notable deficiency in the comprehensive understanding of the challenges and benefits associated with these new technologies, especially with their complementary natures and integration architectures. This paper aims to bridge the knowledge gap in ADMS and DERMS integration, presenting three distinct integration architectures currently available, and discussing the challenges and benefits of each architecture to guide utilities, industry professionals, and researchers in optimizing grid management and decision-making processes for a resilient and efficient energy future.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Performance of Integrated Systems of Automated Roller Shade Systems and Daylight Responsive Dimming Systems

Daylight responsive dimming systems have been used in few buildings to date because they require improvements to improve reliability. The key underlying factor contributing to poor performance is the variability of the ratio of the photosensor signal to daylight workplane illuminance in accordance with sun position, sky condition, and fenestration condition. Therefore, this paper describes the integrated systems between automated roller shade systems and daylight responsive dimming systems with an improved closed-loop proportional control algorithm, and the relative performance of the integrated systems and single systems. The concept of the improved closed-loop proportional control algorithm for the integrated systems is to predict the varying correlation of photosensor signal to daylight workplane illuminance according to roller shade height and sky conditions for improvement of the system accuracy. In this study, the performance of the integrated systems with two improved closed-loop proportional control algorithms was compared with that of the current (modified) closed-loop proportional control algorithm. In the results, the average maintenance percentage and the average discrepancies of the target illuminance, as well as the average time under 90percent of target illuminance for the integrated systems significantly improved in comparison with the current closed-loop proportional control algorithm for daylight responsive dimming systems as a single system.

30 DIRECT ENERGY CONVERSION↗

Development of a Discrepancy Checker for the Digital Twin in a Supervisory Control System for a Thermal Energy Delivery System

Defined as a virtual representation of a physical object, process, or service, and used to support real-world decision-making, a digital twin (DT) can be utilized to combine classical and novel frameworks in sensors, state predictions, and multi-input/multi-output systems, and to enable optimal autonomous operations. However, a DT’s usefulness largely depends on its ability to adequately mirror the state of its physical counterpart, and this adequacy should be reflected by the level of uncertainty in the underlying simulation models when estimating and predicting quantities of interest (QOIs). Moreover, simulation models in a DT may involve multiple fidelities of representations—ranging from physics-based models to data-driven ones—but classical uncertainty quantification (UQ) methods struggle to handle numerous uncertainty sources, nor are they designed for real-time applications. This work presents a UQ-based discrepancy checking and diagnosis tool for a DT-based supervisory control system applied to a thermal energy delivery system (TEDS) at Idaho National Laboratory. The discrepancy checker was developed using metadata from an automated DT development process, and these metadata included different combinations of physical model forms and model parameters, training data and hyperparameters for surrogate models, and design parameters for supervisory control systems. Next, correlations between the uncertainty results and the metadata were established and then applied to the DT operations. The discrepancy checker evaluates the discrepancies between model predictions from virtual and sensor measurements and backtraces them to the corresponding major sources of uncertainty. The discrepancy checker showed reasonable performance in detecting discrepancies and diagnosing sources of uncertainty in testing scenarios.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Autonomous elemental characterization enabled by a low cost robotic platform built upon a generalized software architecture

Despite the rapidly growing applications of robots in industry, the use of robots to automate tasks in scientific laboratories is less prolific due to the lack of generalized methodologies and the high cost of hardware. This paper focuses on the automation of characterization tasks necessary for reducing cost while maintaining generalization and proposes a software architecture for building robotic systems in scientific laboratory environments. A dual-layer (Socket.IO and ROS) action server design is the basic building block, which facilitates the implementation of a web-based front end for user-friendly operation and the use of ROS Behavior Trees for convenient task planning and execution. A robotic platform for automating mineral and material sample characterization is built upon the architecture, with an open-source, low-cost three-axis computer numerical control gantry system serving as the main robot. A handheld laser induced breakdown spectroscopy (LIBS) analyzer is integrated with a 3D printed adapter, enabling (1) automated 2D chemical mapping and (2) autonomous sample measurement (with the support of an RGB-Depth camera). We demonstrate the utility of automated chemical mapping by scanning the surface of a spodumene-bearing pegmatite core sample with a 1071-point dense hyperspectral map acquired at a rate of 1520 bits per second. Furthermore, we showcase the autonomy of the platform in terms of perception, dynamic decision-making, and execution, through a case study of LIBS measurement of multiple mineral samples. The platform enables controlled and autonomous chemical quantification in the laboratory that complements field-based measurements acquired with the same handheld device, linking resource exploration and processing steps in the supply chain for lithium-based battery materials.

Cao, Xuan [Lawrence Berkeley National Laboratory (↗

Modular Controllable Transformers (MCT)

Large Power Transformers (LPTs) are at the heart of the electricity infrastructure and are critical pieces in today’s grid. Aging assets, long turn-around times, transportation delays and dependence on foreign manufacturing for these components have created conditions for points of failure across the system. Moreover, there is no available dynamic control on these passive sections of the grid. For all the automation embedded on the low voltage side of the low voltage side of the system there is absolutely no flexibility on the high voltage side. Changes in power flow patterns are brought about by altering dispatch patterns for generators which requires a coordinated effort and is often time consuming. Traditional FACTS based approaches such as UPFC or HVDC light involve massive modifications to the existing infrastructure. Recent instances of physical attacks on LPTs and the slow recovery process associated with fixing or replacing these damaged units has created an increased awareness for this issue. LPT designs are highly customized owing to specific field requirements. Long lead times coupled with transportation delays make procuring and installing LPTs a lengthy process. In an attempt to minimize the recovery time following an LPT failure, transformer manufacturers have developed mobile transformer units. These units typically consist of either a single-phase or three-phase transformer mounted on a truck and characterized by compact form factors. By reducing the assembly time and transport time these units offer a fast and temporary solution to LPT failures. Several efforts led by DOE, Edison Electric Company (EEI) and North American Electric Reliability Corporation (NERC) have led to the RecX program. RecX transformers consist of single phase transformers transported on specialized assemblies to enable fast restoration and minimal installation time. NERC and EEI have instituted transformer sharing programs like Spare Equipment Database (SED) as well as Spare Transformer Equipment Database (STEP) which encourage utilities to maintain and share a fleet of LPTs. Mobile transformers are typically limited to less than 100 MVA to enable transportation on a trailer. Also, the efficiency of mobile transformer units and RecX transformers is lower since they are temporary solutions. The ideal replacement solution would be one that could utilize a set of standardized transformers while incorporating flexibility to influence metrics like power flow, apparent impedance and voltage profiles. In view of these issues the team at Georgia Tech proposed a concept called Modular Controllable Transformers (MCTs). This project was commissioned as a part of DOE’s Transformer Resiliency and Advance Component (TRAC) program. The approach consists of splitting one large unit rated upwards of 100 MVA with smaller modular, standardized units. Each of these smaller units are augmented with a converter to add power flow, voltage and impedance control. Splitting the power level into multiple units has two important implications. By making smaller units, the transportation times can be reduced drastically. Moreover, even though these units have very specific impedance and other parameters, the augmented converters can make it emulate the unit being replaced. Thus, faster replacement times and added controls are achieved making this an extremely resilient approach. In the event of one modular units failure, the other two controllable units can operate in the most resilient fashion keeping the net system overloads to a minimum. Moreover, for the same probability of failure only a fraction of the system capacity is lost. The converter is augmented on to the tertiary winding of the transformer making it retrofittable in the field without massive modifications to the system. The material proposed in this report highlights design considerations to minimize recovery time as well as results displaying overall improvement in resiliency. The cost analysis of this approach shows significant savings compared to UPFC and HVDC lite based approaches. Extensive analysis was conducted on numerous aspects of this project over the course of this project. Simulation studies were conducted to prove the 5MVA converter design. Challenging BIL constraints and transient issues were addressed over the course of this project. Simulations on EMTP platform presented in consequent sections were used to finely tune the control for the same. A final design for a back-to-back 5MVA neutral-point-clamped (NPC) converter was completed in this project. Furthermore, switching components like high power IGBTs from IXYS Westcode Press-Pack series and ABB Stackpack series were identified for this application. These devices exhibit a blocking voltage of 6.5 kV and a nominal collector current of 900 A. Potential housing options as well as existing commercial option were identified for this converter design. A 56 MVA modular transformer unit was designed with Delta Star Inc. with consultation and inputs from all project members. The transformer cooling systems were chosen to be Oil Natural Air Forced (ONAF) to optimize ease of transport. A full Product Requirement Document (PRD) for the converter and the transformer was generated. The team also investigated key aspects of resiliency and how to quantify the same. A metric was developed to analyze resiliency and numerous simulation cases were presented. Increased (N-1) resiliency and outage resistance was showcased through simulation on the Texas Large scale power system. Dynamic control capabilities were also showcased on numerous system level simulations. An IEEE 30 bus system was used to show the ability of the MCT approach to reduce line congestion. Power flow control; a part of the MCTs abilities, showcased a 29% reduction in transformer loading on the same system. Full control over tie line flows was demonstrated on a modified IEEE 13 bus system. Dynamic LTC capabilities were shown through simulation and were compared to traditional LTCs. Furthermore, the ability of the MCTs to alter apparent transformer impedance was simulated to promote standardization of modular transformer units while retaining the ability to emulate a varied range of impedance characteristics. Thus granular control over power flow, voltages, impedances and was presented. Regulatory analysis conducted by Oak Ridge National Laboratory (ORNL) further bolstered the efficacy of the MCT approach and verified the added resiliency achieved due to this approach. As a conclusion, it was proved that the resilience improvement obtained from using the MCT approach is justified by just one failure in a 30-year period. This means that the benefits obtained from using the MCT approach far outweigh the cost of setting this approach up. As a part of the future efforts, the team is proposing building a (12.47-24) kV/400 kVA scaled down unit to control 5MVA of power flows. Emphasis would be laid on using commercial components to speed up the build of these units. Further the actual transport of the modular transformer unit would be a part of this operation and would provide insight into transportation issues. The approach shows much promise and adds key dynamic control on passive sub transmission and transmission sectors.

24 POWER TRANSMISSION AND DISTRIBUTION↗

QA Issues for Computer-Controlled Treatment Delivery: This Is Not Your Old R/V System Any More{exclamation_point}

State-of-the-art radiotherapy treatment delivery has changed dramatically during the past decade, moving from manual individual field setup and treatment to automated computer-controlled delivery of complex treatments, including intensity-modulated radiotherapy and other similarly complex delivery strategies. However, the quality assurance methods typically used to ensure treatment is performed precisely and correctly have not evolved in a similarly dramatic way. This paper reviews the old manual treatment process and use of record-and-verify systems, and describes differences with modern computer-controlled treatment delivery. The process and technology used for computer-controlled treatment delivery are analyzed in terms of potential (and actual) problems, as well as relevant published guidance on quality assurance. The potential for improved quality assurance for computer-controlled delivery is discussed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

lumicap v0.1

Automated HDR luminance imaging system designed for daylighting research and building science. It controls a fisheye-lens camera to capture time-lapse bracket sequences, merges them into calibrated HDR images, and runs a full post-processing pipeline — all unattended. Features: - Scheduled LDR bracket capture via gphoto2 - HDR merging with vignetting, ND filter, and fisheye projection corrections - Illuminance and luminance meter integration (Konica Minolta T-10A, LS-100/150) - Daylight glare probability (DGP) and solar position computation - Automated false-color rendering, JPEG thumbnails, and daily time-lapse video - CSV data logging per timestep Uses: - Long-term monitoring of daylight conditions in buildings - Glare analysis for occupant comfort research - Solar irradiance and sky luminance studies Advantages: - End-to-end automation — capture, calibration, analysis, and archiving run without manual intervention - Built on the proven Radiance toolchain, ensuring photometrically accurate HDR output - Hardware-agnostic meter support via serial auto-detection - Lightweight — no GUI overhead, deployable on a headless Raspberry Pi or similar embedded system

Wang, Taoning [Lawrence Berkeley National Laborato↗

Considerations for AMI-Based Operations for Distribution Feeders

More than $5 billion in investments in advanced metering infrastructure (AMI) technologies, AMI deployments, as pervasive secondary network voltage monitoring systems, provide opportunities for utility operations and controls. This paper focuses on the considerations for AMI-based tools and techniques as the industry moves toward operationalizing such large data sets. Phase identification is a first such tool. Numerous distribution network analysis, monitoring, and control applications - including volt/volt-ampere reactive control, state estimation, and distribution automation - require accurate phase connectivity information in the system models. The phase connectivity database maintained by utilities is inaccurate because of a significant amount of missing data, restoration activities, and network reconfiguration. Existing phase identification techniques that estimate phase connectivity work well in distribution feeders that have low or no photovoltaic (PV) generation; however, they fail to identify the phases accurately when considerable PV generation is present. This work addresses the phase identification problem in the presence of high PV generation using statistical analysis methods. Further, insights into the AMI data requirements for this application in terms of data window length and resolution are provided using sensitivity analysis performed on an actual distribution feeder model of San Diego Gas & Electric Company. The results of this study show that the phase connectivity, even in the presence of high PV generation, can be accurately identified using statistical analysis of AMI data of 1 day.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Considerations for AMI-Based Operations for Distribution Feeders: Preprint

More than $5 billion in investments in advanced metering infrastructure (AMI) technologies, AMI deployments, as pervasive secondary network voltage monitoring systems, provide opportunities for utility operations and controls. This paper focuses on the considerations for AMI-based tools and techniques as the industry moves toward operationalizing such large data sets. Phase identification is a first such tool. Numerous distribution network analysis, monitoring, and control applications - including volt/volt-ampere reactive control, state estimation, and distribution automation - require accurate phase connectivity information in the system models. The phase connectivity database maintained by utilities is inaccurate because of a significant amount of missing data, restoration activities, and network reconfiguration. Existing phase identification techniques that estimate phase connectivity work well in distribution feeders that have low or no photovoltaic (PV) generation; however, they fail to identify the phases accurately when considerable PV generation is present. This work addresses the phase identification problem in the presence of high PV generation using statistical analysis methods. Further, insights into the AMI data requirements for this application in terms of data window length and resolution are provided using sensitivity analysis performed on an actual distribution feeder model of San Diego Gas & Electric Company. The results of this study show that the phase connectivity, even in the presence of high PV generation, can be accurately identified using statistical analysis of AMI data of 1 day.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Maximum-impact Adversary Design for Network-based Control System: A Case Study on Grid-interactive Efficient Buildings

The Internet of Things (IoT) technology has dramatically improved the efficiency of today's building operation and management. By connecting controllable devices into a communication network, control signals can be easily passed to the devices, and operating status can be acquired from measurable ends with minimal effort. However, this all-connected configuration could also expose the network-based control system (NBCS) to malicious actions, such as cyberattacks. One of the common NBCSs is the building automation system. With the promotion of grid-interactive efficient buildings (GEBs), there has been increasing attention on securing the buildings from the network perspective. This research proposes a maximum-impact adversary design framework so that the adversary can provide the most adversarial impact on the controlled system while remaining stealthy. The proposed framework is numerically demonstrated on a network-based building energy and control system. The building energy system is built in a Modelica-based simulation environment and controlled by the state-of-the-art ASHRAE Guideline 36 control sequences. The control commands at the supervisory level, generated from the Guideline 36 controller, are assumed to be sent to local devices through communication networks using the BACnet protocol. Simulation results show that the proposed maximum-impact adversary on such a system can stealthily affect the building system's performance to its maximum extent. It is anticipated that results can be used by researchers and practitioners in the building automation industry to design efficient and robust cyber-attack detection algorithms, especially for stealthy attacks.

Chu, Mengyuan↗

Open Automated Demand Response Dynamic Pricing Technologies and Demonstration

This study examines the use of OpenADR communications specification, related data models, technologies, and strategies to send dynamic prices (e.g., real time prices and peak prices) and Time of Use (TOU) rates to commercial and industrial electricity customers. OpenADR v1.0 is a Web services-based flexible, open information model that has been used in California utilities' commercial automated demand response programs since 2007. We find that data models can be used to send real time prices. These same data models can also be used to support peak pricing and TOU rates. We present a data model that can accommodate all three types of rates. For demonstration purposes, the data models were generated from California Independent System Operator's real-time wholesale market prices, and a California utility's dynamic prices and TOU rates. Customers can respond to dynamic prices by either using the actual prices, or prices can be mapped into"operation modes," which can act as inputs to control systems. We present several different methods for mapping actual prices. Some of these methods were implemented in demonstration projects. The study results demonstrate show that OpenADR allows interoperability with existing/future systems/technologies and can be used within related dynamic pricing activities within Smart Grid.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Exploration of PG&E Auto DR Incentive Options (Final Project Report)

Demand Response programs offer incentives to customers to modify energy use during times of peak demand. There is a growing trend toward automating demand response. The market benefits from the use of common communication standards to facilitate automation because it allows communication and control companies to build technology using common protocols that reduces the cost of integrating ADR technologies into buildings. Common communication standards also allow electricity providers to build common platforms to communicate with customer or aggregator end-use equipment. This report considers strategies for increasing the use of automated DR technology for residential and small and medium business (SMB) customers within the Pacific Gas and Electric (PG&E) service territory. PG&E is interested in designing new incentive structures for automated DR equipment. In developing these new structures, it is important to understand the incremental cost of the automated demand response (ADR) communication technology. This technology is usually imbedded in end-use controls to communicate with an end-use device. Standards based ADR technologies require that the control system have the ability to communicate using an open standard communication protocol, usually either Open Automated Demand Response (OpenADR, certification for which is available through the OpenADR Alliance) or Smart Energy Profile.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Science & Technology Review November/December 2008

This months issue has the following articles: (1) Innovation Is Key to Prosperity and Security --Commentary by Erik J. Stenehjem; (2) Taking Ultrafast Snapshots of Material Changes--The dynamic transmission electron microscope captures images a million times faster than conventional instruments; (3) Automated Technology for Laser Fusion Systems--The first completely computer-controlled system for aligning laser beams is helping make fusion research possible; (4) Protecting the Nation through Secure Cargo--A new device tracks and monitors cargo containers during transit to improve national security; (5) Atom by Atom, Layer by Layer--Extremely thin sandwiches of materials called nanolaminates exhibit remarkable, highly useful properties; and (6) Predicting the Bizarre Properties of Plutonium--A supercomputing 'grand challenge' team has made highly precise predictions of the behavior of plutonium's most important solid phase.

36 MATERIALS SCIENCE↗

VOLTTRON - An Intelligent Agent Platform for the Smart Grid

The distributed nature of the Smart Grid, such as responsive loads, solar and wind generation, and automation in the distribution system present a complex environment not easily controlled in a centralized manner.

24 POWER TRANSMISSION AND DISTRIBUTION↗