Search NASA⌕ Search

SEARCH · Search NASA

Results for “BEAM PROFILES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Harmonic plasma waves excitation and structure evolution of intense ion beams in background plasmas

The long-term dynamic evolutions of intense ion beams in plasmas have been investigated with two-dimensional electromagnetic particle simulations, taking into account the effect of the two-stream instability between beam ions and plasma electrons. Depending on the initial beam radial density profile and velocity distribution, ring structures may be formed in the beam edge regions. At the later stage of beam-plasma interactions, the ion beams are strongly modulated by the two-stream instability and multiple density spikes are formed in the longitudinal direction. The formation of these density spikes is shown to result from the excitation of harmonic plasma waves when the instability gets saturated. Comparisons between the beam cases with initial flat-top and Gaussian radial density profiles are made, and a higher instability growth rate is observed for the flat-top profile case.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Demonstration of Current Profile Shaping using Double Dog-Leg Emittance Exchange Beam Line at Argonne Wakefield Accelerator

Emittance exchange (EEX) based longitudinal current profile shaping is the one of the promising current profile shaping technique. This method can generate high quality arbitrary current profiles under the ideal conditions. The double dog-leg EEX beam line was recently installed at the Argonne Wakefield Accelerator (AWA) to explore the shaping capability and confirm the quality of this method. To demonstrate the arbitrary current profile generation, several different transverse masks are applied to generate different final current profiles. The phase space slopes and the charge of incoming beam are varied to observe and suppress the aberrations on the ideal profile. We present current profile shaping results, aberrations on the shaped profile, and its suppression.

43 PARTICLE ACCELERATORS↗

Gas Jet Profile Monitor for Use in IOTA Proton Beam

The Integrable Optics Test Accelerator (IOTA) at the Fermilab Accelerator Science and Technology (FAST) Facility will attempt to demonstrate novel techniques for high current accelerators. An electron beam of 150 MeV/c momentum and a proton beam of 70 MeV/c momentum will be used for a number of experiments, including nonlinear focusing integrable optics, space charge compensation, and optical stochastic cooling. The low energy proton beam will provide a space charge dominated regime with which to investigate Hamiltonian diffusion and chaos. A non-invasive beam instrumentation device is needed to study emittance evolution and halo formation without destroying the beam. A supersonic gas jet curtain can be injected perpendicular to the proton beam, which will preserve the integrity of the beam and provide a two-dimensional turn-by-turn profile measurement. Currently, IOTA and the gas jet monitor are being built and commissioned at Fermilab.

43 PARTICLE ACCELERATORS↗

MO-FG-CAMPUS-JeP1-02: Proton Range Verification of Scanned Pencil Beams Using Prompt Gamma Imaging

Purpose: Prompt gammas are emitted along the proton beam path and have an emission profile correlated with the depth dose profile. In this study, the accuracy of in-vivo proton range verification using a 1-D prompt gamma camera is assessed. Methods: The 1-D camera is comprised of a tungsten slit collimator positioned in front of a linear array of LYSO scintillating crystals coupled to silicon photomultipliers. The imaged gamma profiles of individual pencil beam spots and energy layers were analyzed by determining the relative shifts from the expected gamma profiles based on analytic prediction or reference measurements. The range retrieval precision was evaluated by reproducibility measurements and by irradiation through a heterogeneous phantom composed of materials with known stopping power ratios. The camera was evaluated at clinical doses in pencil beam scanning mode on a head-and-neck phantom (HN). Two scenarios were studied: 5 mm systematic range error; and setup error of 10 mm transverse to the proton beam. Results: The camera range retrieval precision was 2 mm at clinical doses. For the heterogeneous phantom and HN phantom studies, the discrepancies between the analytic model and measurements were less than 2 mm for both spot and iso-energy layer analysis. For the simulated 5 mm range error, the retrieved shifts were 4.3±2.0 mm. For the 10 mm setup error, large shifts (> 4 mm) were observed for some spots due to differences in the irradiated and expected beam path from the measurements without setup error. Conclusion: Our studies demonstrated that in-vivo proton range verification is feasible using a 1D prompt gamma camera with a 2 mm range retrieval precision. Pencil beam spot under or over ranging can be detected via comparison between measured and expected profiles.

60 APPLIED LIFE SCIENCES↗

Update on developments at SNIF

The Small Negative Ion Facility (SNIF) at CCFE has been undergoing continuous development and enhancement to both improve operational reliability and increase diagnostic capability. SNIF uses a CW 13.56MHz, 5kW RF driven volume source with a 30kV triode accelerator. Improvement and characterisation work includes: Installation of a new “L” type RF matching unit, used to calculate the load on the RF generator. Use of the electron suppressing biased insert as a Langmuir probe under different beam extraction conditions. Measurement of the hydrogen Fulcher molecular spectrum, used to calculate gas temperature in the source. Beam optimisation through parameter scans, using copper target plate and visible cameras, with results compared with AXCEL-INP to provide beam current estimate. Modelling of the beam power density profile on the target plate using ANSYS to estimate beam power and provide another estimate of beam current. This work is described, and has allowed an estimation of the extracted beam current of approximately 6mA (4mA/cm2) at 3.5kW RF power and a source pressure of 0.6Pa.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

MO-F-CAMPUS-T-03: Verification of Range, SOBP Width, and Output for Passive-Scattering Proton Beams Using a Liquid Scintillator Detector

Purpose: Liquid scintillators have been shown to provide fast and high-resolution measurements of radiation beams. However, their linear energy transfer-dependent response (quenching) limits their use in proton beams. The purpose of this study was to develop a simple and fast method to verify the range, spread-out Bragg peak (SOBP) width, and output of a passive-scattering proton beam with a liquid scintillator detector, without the need for quenching correction. Methods: The light signal from a 20×20×20 cm3 liquid scintillator tank was collected with a CCD camera. Reproducible landmarks on the SOBP depth-light curve were identified which possessed a linear relationship with the beam range and SOBP width. The depth-light profiles for three beam energies (140, 160 and 180 MeV) with six SOBP widths at each energy were measured with the detector. Beam range and SOBP width calibration factors were obtained by comparing the depth-light curve landmarks with the nominal range and SOBP width for each beam setting. The daily output stability of the liquid scintillator detector was also studied by making eight repeated output measurements in a cobalt-60 beam over the course of two weeks. Results: The mean difference between the measured and nominal beam ranges was 0.6 mm (σ=0.2 mm), with a maximum difference of 0.9 mm. The mean difference between the measured and nominal SOBP widths was 0.1 mm (σ=1.8 mm), with a maximum difference of 4.0 mm. Finally an output variation of 0.14% was observed for 8 measurements performed over 2 weeks. Conclusion: A method has been developed to determine the range and SOBP width of a passive-scattering proton beam in a liquid scintillator without the need for quenching correction. In addition to providing rapid and accurate beam range and SOBP measurements, the detector is capable of measuring the output consistency with a high degree of precision. This project was supported in part by award number CA182450 from the National Cancer Institute.

07 ISOTOPE AND RADIATION SOURCES↗

SU-E-T-361: Energy Dependent Radiation/light-Field Misalignment On Truebeam Linear Accelerator

Purpose: Verifying the co-incidence of the radiation and light field is recommended by TG-142 for monthly and annual checks. On a digital accelerator, it is simple to verify that beam steering settings are consistent with accepted and commissioned values. This fact should allow for physicists to verify radiation-light-field co-incidence for a single energy and accept that Result for all energies. We present a case where the radiation isocenter deviated for a single energy without any apparent modification to the beam steering parameters. Methods: The radiation isocenter was determined using multiple Methods: Gafchromic film, a BB test, and radiation profiles measured with a diode. Light-field borders were marked on Gafchromic film and then irradiated for all photon energies. Images of acceptance films were compared with films taken four months later. A phantom with a radio-opaque BB was aligned to isocenter using the light-field and imaged using the EPID for all photon energies. An unshielded diode was aligned using the crosshairs and then beam profiles of multiple field sizes were obtained. Field centers were determined using Omni-Pro v7.4 software, and compared to similar scans taken during commissioning. Beam steering parameter files were checked against backups to determine that the steering parameters were unchanged. Results: There were no differences between the configuration files from acceptance. All three tests demonstrated that a single energy had deviated from accepted values by 0.8 mm in the inline direction. The other two energies remained consistent with previous measurements. The deviated energy was re-steered to be within our clinical tolerance. Conclusions: Our study demonstrates that radiation-light-field coincidence is an energy dependent effect for modern linacs. We recommend that radiation-light-field coincidence be verified for all energies on a monthly basis, particularly for modes used to treat small fields, as these may drift without influencing results from other tests.

60 APPLIED LIFE SCIENCES↗

Self-focusing of pseudo-nondiffracting laser beams with circular symmetry in collisional plasma under two ramp density profiles

The self-focusing of zeroth-order Bessel–Gaussian beams through plasma under exponential and tangential ramp density profiles is investigated theoretically by using Wentzel–Kramers–Brillouin approximation. To examine the effect of plasma density ramp on self-focusing of the studied beams, the evolution of beam-width parameter with normalized propagation distance is reported for diverse laser beams and plasma parameters. The results reveal that stronger self-focusing is obtained with exponential ramp density profile as compared to the tangential density ramp one.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Device and method for creating Gaussian aberration-corrected electron beams

Electron beam phase gratings have phase profiles that produce a diffracted beam having a Gaussian or other selected intensity profile. Phase profiles can also be selected to correct or compensate electron lens aberrations. Typically, a low diffraction order produces a suitable phase profile, and other orders are discarded.

43 PARTICLE ACCELERATORS↗

Precision Control of the Electron Longitudinal Bunch Shape Using an Emittance-Exchange Beam Line

We report on the experimental generation of relativistic electron bunches with a tunable longitudinal bunch shape. A longitudinal bunch-shaping (LBS) beam line, consisting of a transverse mask followed by a transverse-to-longitudinal emittance exchange (EEX) beam line, is used to tailor the longitudinal bunch shape (or current profile) of the electron bunch. The mask shapes the bunch’s horizontal profile, and the EEX beam line converts it to a corresponding longitudinal profile. The Argonne wakefield accelerator rf photoinjector delivers electron bunches into a LBS beamline to generate a variety of longitudinal bunch shapes. The quality of the longitudinal bunch shape is limited by various perturbations in the exchange process. We develop a simple method, based on the incident slope of the bunch, to significantly suppress the perturbations

Ha, G.↗

Simulations of the Electron Column in IOTA

Future high current proton accelerators will need to minimize beam loss due to space-charge in order to achieve safe operation while achieving the desired physics goals. One method of space-charge compensation to be tested at the Integrable Optics Test Accelerator (IOTA) at Fermilab is the Electron Column. The concept for this device is to allow a circulating beam to ionize a small region of relatively high pressure residual gas, while using electric and magnetic fields to confine and shape the resulting plasma electrons. If the profile of the electrons is matched to the beam profile transversely and longitudinally, the electrons should counteract the space-charge force of the proton beam. Simulations of the IOTA proton beam circulating through the Electron Column have been performed, with the evolution of the electron plasma and its effect on the beam studied.

43 PARTICLE ACCELERATORS↗

Geometry-based, Gaussian profile model for optical knife-edge displacement sensor

This article describes an analytical model for the well-known optical knife-edge displacement sensor that predicts the relationship between the knife-edge displacement and photointerrupter output. The model includes: 1) the geometry of a rectangular knife-edge profile penetrating a circular laser beam perpendicular to the beam axis; and 2) the Gaussian intensity profile for the beam cross-section. A comparison between the model predictions and measured photointerrupter for a linear range of knife-edge displacements is provided. It is shown that good agreement is obtained without model calibration.

42 ENGINEERING↗

Conceptual design of a three-pole wiggler for the APS upgrade

The current design of the Advanced Photon Source Upgrade (APS-U) project is a multi-bend achromat (MBA) lattice, which incorporates three-pole wigglers as radiation sources for the bending magnet beamlines. They are located in the short section between the M4 dipole and Q8 quadrupole magnets. Due to space constraints, a hybrid permanent magnet design is necessary to provide the required magnetic field strength. A three-pole wiggler with a flat peak field profile along the beam axis was designed to enhance the photon flux and flatten the transverse flux density distributions. The magnetic peak field at the center pole reached 1.08 Tesla for a magnetic gap of 26 mm. The maximum power density, integrated over all vertical angles, is 3.1 W/mm{sup 2}, which is substantially higher than that of the existing bending magnets at the APS (0.86 W/mm{sup 2}). Detailed designs of the three-pole wiggler is presented, including calculated spectral-angular flux distributions.

43 PARTICLE ACCELERATORS↗

A determination of the current density in electron beams

Current gathering rotating probe techniques were used to examine the envelope shape and power density profile of electron beams used in electron beam welding devices. The electron power density contours which determine the shape of the weld vapor cavity, penetration, and local heat distribution were considered. A mathematical analysis consistent with a rotating probe technique necessary to determine the current density distribution (assumed symmetrically radial) in a cross-section of the beam is provided. An explanation of the experimental technique for obtaining data, a BASIC language computer program to determine the current density from the data, and a study indicating the level of confidence to be associated with results obtained are also provided. An example of the application of the analysis to some experimental electron beam data is included.

Beil, R. J.↗

The scoping, design, and plasma physics optimization of the Eos neutron source stellarator

On the path to a fusion pilot plant, Thea Energy plans to build Eos, a sub-breakeven, deuterium-deuterium, beam-target fusion, stellarator neutron source facility for producing tritium and other valuable radioisotopes. In this paper, a set of 1D plasma physics models are coupled and used to design the operating point of the facility and predict performance. At this foundational stage of the design, analytic and approximate models are sufficient to capture the leading-order effects, and fast enough to run in the inner loop of an optimizer. Higher-fidelity analyses will follow. Models of 1D profile-dependent neutral beam stopping, ion beam slowing down, beam-target fusion, electron-ion classical heat transfer, energy confinement (ISS04), beam pressure, beam heating of ions and electrons, beam-beam fusion fraction, and neutral beam injection and gyrotron heating electrical efficiencies are included. A numerical optimizer is used to determine the minimum required facility electric power to generate tritium at a given rate. A potentially advantageous regime is described in which modern precisely-quasisymmetric stellarators, new high-temperature superconductors, ITER-derived neutral beam injection, and new high-frequency gyrotrons enable a suitible target plasma with hot electrons, cold ions, peaked density and temperature profiles, and high beam-injected ion density. It appears possible at this time for a facility with a medium-scale and medium-strength stellarator whose required facility electric power is less than 40 MW to produce $2.5\times 10^{17}$ neutrons s -1 for the production of radioisotopes. With the addition of a tritium breeding blanket, such a facility could produce 0.2 grams d -1 or 70 grams yr -1 of tritium.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Fast Thermal Helium Beam diagnostic for measurements of edge electron profiles and fluctuations

The edge of fusion experiments is a region where strong gradients develop, together with the presence of strong fluctuations due to turbulence. The thermal helium beam diagnostic developed for the RFX-mod experiment allows the measurements with a single diagnostic of both low frequency time evolution of the edge radial profiles of electron density and temperature (tens of hertz), and the high frequency fluctuations (hundreds of kHz). To maximize the collected light, the three HeI lines necessary to be measured for the evaluation of n{sub e} and T{sub e} are separated with a spectrograph, and multianode photomultipliers are used as light detectors. The paper describes the diagnostic setup, with the interface hardware with the machine and the optical layout, and the characterization of its performances.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-F-T-160: Commissioning of a Single-Room Double-Scattering Proton Therapy System

Purpose: To report the detailed commissioning experience for a compact double-scattering Mevion S250 proton therapy system at a University Cancer Center site. Methods: The commissioning of the proton therapy system mainly consisted of ensuring integrity of mechanical and imaging system, beam data collection, and commissioning of a treatment planning system (TPS). First, mechanical alignment and imaging were tested including safety, interlocks, positional accuracy of couch and gantry, image quality, mechanical and imaging isocenter and so on. Second, extensive beam data (outputs, PDDs, and profiles) were collected and analyzed through effective sampling of range (R) and modulation width (M) from 24 beam options. Three different output (cGy/MU) prediction models were also commissioned as primary and secondary MU calculation tool. Third, the Varian Eclipse TPS was commissioned through five sets of data collections (in-water Bragg peak scans, in-air longitudinal fluence scans, in-air lateral profiles, in-air half-beam profiles, and an HU-to-stopping-power conversion curve) and accuracy of TPS calculation was tested using in-water scans and dose measurements with a 2D array detector with block and range compensator. Finally, an anthropomorphic phantom was scanned and heterogeneity effects were tested by inserting radiochromic films in the phantom and PET activation scans for range verification in conjunction with end-to-end test. Results: Beam characteristics agreed well with the vendor specifications; however, minor mismatches in R and M were found in some measurements during the beam data collection. These were reflected into the TPS commissioning such that the TPS could accurately predict the R and M within tolerance levels. The output models had a good agreement with measured outputs (<3% error). The end-to-end test using the film and PET showed reasonably the TPS predicted dose, R and M in heterogeneous medium. Conclusion: The proton therapy system was successfully commissioned and was released for clinical use.

60 APPLIED LIFE SCIENCES↗

SU-F-T-71: A Practical Method for Evaluation of Electron Virtual Source Position

Purpose: Since electrons are easily scattered, the virtual source position for electrons is expected to locate below the x-ray target of Medical Linacs. However, the effective SSD method yields the electron virtual position above the x-ray target for some applicators for some energy in Siemens Linacs. In this study, we propose to use IC Profiler (Sun Nuclear) for evaluating the electron virtual source position for the standard electron applicators for various electron energies. Methods: The profile measurements for various nominal source-to-detector distances (SDDs) of 100–115 cm were carried out for electron beam energies of 6–18 MeV. Two methods were used: one was to use a 0.125 cc ion chamber (PTW, Type 31010) with buildup mounted in a PTW water tank without water filled; and the other was to use IC Profiler with a buildup to achieve charge particle equilibrium. The full width at half-maximum (FWHM) method was used to determine the field sizes for the measured profiles. Backprojecting (by a straight line) the distance between the 50% points on the beam profiles for the various SDDs, yielded the virtual source position for each applicator. Results: The profiles were obtained and the field sizes were determined by FWHM. The virtual source positions were determined through backprojection of profiles for applicators (5, 10, 15, 20, 25). For instance, they were 96.415 cm (IC Profiler) vs 95.844 cm (scanning ion chamber) for 9 MeV electrons with 10×10 cm applicator and 97.160 cm vs 97.161 cm for 12 MeV electrons with 10×10 cm applicator. The differences in the virtual source positions between IC profiler and scanning ion chamber were within 1.5%. Conclusion: IC Profiler provides a practical method for determining the electron virtual source position and its results are consistent with those obtained by profiles of scanning ion chamber with buildup.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗