Search NASA⌕ Search

SEARCH · Search NASA

Results for “Bayesian parameter estimation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Artificial Neural Network-Based Monitoring of the Fuel Assembly Temperature Sensor and FPGA Implementation

Numerous methods have been developed around the world to model the dynamic behavior and detect a faulty operating mode of a temperature sensor. In this context, we present in this study a new method based on the dependence between the fuel assembly temperature profile on control rods positions, and the coolant flow rate in a nuclear reactor. This seems to be possible since the insertion of control rods at different axial positions and variations in flow rate of the reactor coolant results in different produced thermal power in the reactor. This is closely linked to the instant fuel rod temperature profile. In a first step, we selected parameters to be used and confirmed the adequate correlation between the chosen parameters and those to be estimated by the proposed monitoring system. In the next step, we acquired and de-noised the data of corresponding parameters, the qualified data is then used to design and train the artificial neural network. The effective data denoising was done by using the wavelet transform to remove a various kind of artifacts such as inherent noise. With the suitable choice of wavelet level and smoothing method, it was possible for us to remove all the non-required artifacts with a view to verify and analyze the considered signal. In our work, several potential mother wavelet functions (Haar, Daubechies, Bi-orthogonal, Reverse Bi-orthogonal, Discrete Meyer and Symlets) were investigated to find the most similar function with the being processed signals. To implement the proposed monitoring system for the fuel rod temperature sensor (03 wire RTD sensor), we used the Bayesian artificial neural network 'BNN' technique to model the dynamic behavior of the considered sensor, the system correlate the estimated values with the measured for the concretization of the proposed system we propose an FPGA (field programmable gate array) implementation. The monitoring system use the correlation. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

The decay of HIV under anti-retroviral therapy is biphasic even in humanized mice with just T cells

HIV-1 plasma viral load decays in a biphasic manner during antiretroviral therapy (ART). It was hypothesized that this is due to infection of different cell types, namely CD4+ T cells and macrophages. We studied this possibility directly by modeling the decay of HIV-1 in humanized mice. We utilized previously published data from humanized T-cell only mice (TOM) and myeloid-only mice (MOM) infected with HIV-1 and treated with a potent ART regimen. Viral load decay dynamics were modeled using either a single or a biexponential decay fitted using nonlinear mixed effects techniques. Fits were compared using the corrected Bayesian information criterion (BICc). In TOM, the biphasic model was significantly better than a single-phase decay model (ΔBICc ≈ 16) despite additional parameters. In MOM, the biphasic decay was statistically better, but there was substantial uncertainty because the virus goes below detection very fast. The first-phase half-life was consistent between groups (1.2 days in MOM and 1.3 days in TOM) and similar to the half-life estimated in human infection. The second-phase decay in these mice was minimal likely due to low initial viral loads. Additional analyses with mice containing both CD4+ T cells and macrophages or X4-tropic virus-infected MOM mice confirmed the biphasic pattern, demonstrating the robustness of this result. The biphasic decline in HIV-1 occurs, even with only CD4+ T cells, refuting the hypothesis that distinct cell populations (CD4+ T cells and macrophages) drive each decay phase. These findings support an alternative model in which the observed dynamics arise from intrinsic properties of the viral infection lifecycle rather than from cellular compartmentalization.

59 BASIC BIOLOGICAL SCIENCES↗

Hierarchical Bayesian Thermonuclear Rate for the 7 Be(n,p) 7 Li Big Bang Nucleosynthesis Reaction

Big Bang nucleosynthesis provides the earliest probe of standard model physics, at a time when the universe was less than 1000 seconds old. It determines the abundances of the lightest nuclides, which give rise to the subsequent history of the visible matter in the universe. This work derives new 7 Be(n,p) 7 Li thermonuclear reaction rates based on all available experimental information. This reaction sensitively impacts the primordial abundances of 7 Be and 7 Li during big bang nucleosynthesis. We critically evaluate all available data and disregard experimental results that are questionable. For the nuclear model, we adopt an incoherent sum of single-level, two-channel, R -matrix approximation expressions, which are implemented into a hierarchical Bayesian model, to analyze the remaining six data sets we deem most reliable. In the fitting of the data, we consistently model all known sources of uncertainty, including discrepant absolute normalizations of different data sets, and also take the variation of the neutron and proton channel radii into account, hence providing less biased estimates of the 7 Be(n,p) 7 Li thermonuclear rates. From the resulting posteriors, we extract R -matrix parameters ($E_r, γ^2_n, γ^2_p$) and derive excitation energies and partial and total widths. Our fit is sensitive to the contributions of the first three levels above the neutron threshold. Reaction rates were computed by integrating 10,000 samples of the reduced cross section. Our 7 Be(n,p) 7 Li thermonuclear rates have uncertainties between 1.5% and 2.0% at temperatures of ≤1 GK. Finally, we compare our rates to previous results and find that the 7 Be(n,p) 7 Li rates most commonly used in big bang simulations have uncertainties that are too optimistic.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Covariance Matrix Evaluations for Independent Mass Fission Yields

Recent needs for more accurate fission product yields include covariance information to allow improved uncertainty estimations of the parameters used by design codes. The aim of this work is to investigate the possibility to generate more reliable and complete uncertainty information on independent mass fission yields. Mass yields covariances are estimated through a convolution between the multi-Gaussian empirical model based on Brosa's fission modes, which describe the pre-neutron mass yields, and the average prompt neutron multiplicity curve. The covariance generation task has been approached using the Bayesian generalized least squared method through the CONRAD code. Preliminary results on mass yields variance-covariance matrix will be presented and discussed from physical grounds in the case of {sup 235}U(n{sub th}, f) and {sup 239}Pu(n{sub th}, f) reactions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Uncertainty-Aware Machine Learning for Small-Angle X-ray Scattering Analysis in Autonomous Experimentation

Small-angle X-ray scattering (SAXS) is a powerful high-throughput characterization tool for probing nanoscale structure in native sample environments, providing real-time morphological information such as nanoparticle size and shape during synthesis. However, automated SAXS data analysis for extracting meaningful structural parameters is non-trivial and remains a bottleneck in closed-loop experimentation towards autonomous materials discovery, which demands fast, reliable, and uncertainty-aware data analysis. Here, we develop a machine-learning approach for automated SAXS analysis tailored to closed-loop nanoparticle synthesis. A Random Forest (RF) regression model is trained on 100,000 synthetic SAXS curves generated from polydisperse spherical nanoparticles with realistic background contributions. Using normalized one-dimensional SAXS intensity profiles as input, the RF model directly predicts nanoparticle radius, size polydispersity, and background parameters, while the ensemble standard deviation across trees provides built-in uncertainty quantification (UQ). On synthetic data, we show that combining fit-quality metrics (R 2 , MAE) with thresholds on prediction uncertainty reliably identifies accurate parameter estimates without access to ground truth. We then apply the trained model to 365 experimental SAXS profiles of citrate-reduced gold nanoparticles synthesized using an automated droplet-flow microreactor with in situ SAXS at a synchrotron beamline, classifying the results into high- and low-confidence subsets based on UQ metrics. Finally, we integrate RF-based SAXS analysis into a simulated closed-loop optimization campaign using Gaussian process Bayesian optimization to minimize nanoparticle polydispersity, benchmarking against conventional automated Levenberg–Marquardt fitting. The RF-guided campaign exhibits substantially faster convergence and lower relative opportunity cost (∼0.07 vs ∼0.3), demonstrating that uncertainty-aware machine-learning SAXS analysis significantly enhances the efficiency and robustness of autonomous nanomaterials synthesis workflows.

Bayesian optimization↗

Calibration of Multi-Parameter Models of Avascular Tumor Growth Using Time Resolved Microscopy Data

Abstract Two of the central challenges of using mathematical models for predicting the spatiotemporal development of tumors is the lack of appropriate data to calibrate the parameters of the model, and quantitative characterization of the uncertainties in both the experimental data and the modeling process itself. We present a sequence of experiments, with increasing complexity, designed to systematically calibrate the rates of apoptosis, proliferation, and necrosis, as well as mobility, within a phase-field tumor growth model. The in vitro experiments characterize the proliferation and death of human liver carcinoma cells under different initial cell concentrations, nutrient availabilities, and treatment conditions. A Bayesian framework is employed to quantify the uncertainties in model parameters. The average difference between the calibration and the data, across all time points is between 11.54% and 14.04% for the apoptosis experiments, 7.33% and 23.30% for the proliferation experiments, and 8.12% and 31.55% for the necrosis experiments. The results indicate the proposed experiment-computational approach is generalizable and appropriate for step-by-step calibration of multi-parameter models, yielding accurate estimations of model parameters related to rates of proliferation, apoptosis, and necrosis.

60 APPLIED LIFE SCIENCES↗

Host Star Metallicity of Directly Imaged Wide-orbit Planets: Implications for Planet Formation

Directly imaged planets (DIPs) are self-luminous companions of pre-main-sequence and young main-sequence stars. They reside in wider orbits (∼tens to thousands of astronomical units) and generally are more massive compared to the close-in (≲10 au) planets. Determining the host star properties of these outstretched planetary systems is important to understand and discern various planet formation and evolution scenarios. We present the stellar parameters and metallicity ([Fe/H]) for a subsample of 18 stars known to host planets discovered by the direct imaging technique. We retrieved the high-resolution spectra for these stars from public archives and used the synthetic spectral fitting technique and Bayesian analysis to determine the stellar properties in a uniform and consistent way. For eight sources, the metallicities are reported for the first time, while the results are consistent with the previous estimates for the other sources. Our analysis shows that metallicities of stars hosting DIPs are close to solar with a mean [Fe/H] = −0.04 ± 0.27 dex. The large scatter in metallicity suggests that a metal-rich environment may not be necessary to form massive planets at large orbital distances. We also find that the planet mass–host star metallicity relation for the directly imaged massive planets in wide orbits is very similar to that found for the well-studied population of short-period (≲1 yr) super-Jupiters and brown dwarfs around main-sequence stars.

36 MATERIALS SCIENCE↗

Measuring the Hubble Constant with Dark Neutron Star–Black Hole Mergers

Abstract Detection of gravitational waves (GWs) from neutron star-black hole (NSBH) standard sirens provides local measurements of the Hubble constant (H 0 ), regardless of the detection of an electromagnetic (EM) counterpart, given that matter effects can be exploited to break the redshift degeneracy of the GW waveforms. The distinctive merger morphology and the high-redshift detectability of tidally disrupted NSBH make them promising candidates for this method. Also, the detection prospects of an EM counterpart for these systems will be limited toz< 0.8 in the optical, in the era of future GW detectors. Using recent constraints on the equation of state of NSs from multi-messenger observations of NICER and LIGO/Virgo/KAGRA, we show the prospects of measuringH 0 solely from GW observation of NSBH systems, achievable by the Einstein telescope (ET) and Cosmic Explorer (CE) detectors. We first analyze individual events to quantify the effect of high-frequency (≥500 Hz) tidal distortions on the inference of NS tidal deformability parameter (Λ) and hence onH 0 . We find that disruptive mergers can constrain Λ up to  ( 60 % ) more precisely than nondisruptive ones. However, this precision is not sufficient to place stringent constraints on theH 0 from individual events. By performing Bayesian analysis on simulated NSBH data (up toN= 100 events, corresponding to a day of observation) in the ET+CE detectors, we find that NSBH systems enable unbiased 4%–13% precision on the estimate ofH 0 (68% credible interval). This is a similar measurement precision found in studies analyzing NSBH mergers with EM counterparts in the LVKC O5 era.

Astronomy & Astrophysics↗

Rao-Blackwellization for Adaptive Gaussian Sum Nonlinear Model Propagation

When dealing with imperfect data and general models of dynamic systems, the best estimate is always sought in the presence of uncertainty or unknown parameters. In many cases, as the first attempt, the Extended Kalman filter (EKF) provides sufficient solutions to handling issues arising from nonlinear and non-Gaussian estimation problems. But these issues may lead unacceptable performance and even divergence. In order to accurately capture the nonlinearities of most real-world dynamic systems, advanced filtering methods have been created to reduce filter divergence while enhancing performance. Approaches, such as Gaussian sum filtering, grid based Bayesian methods and particle filters are well-known examples of advanced methods used to represent and recursively reproduce an approximation to the state probability density function (pdf). Some of these filtering methods were conceptually developed years before their widespread uses were realized. Advanced nonlinear filtering methods currently benefit from the computing advancements in computational speeds, memory, and parallel processing. Grid based methods, multiple-model approaches and Gaussian sum filtering are numerical solutions that take advantage of different state coordinates or multiple-model methods that reduced the amount of approximations used. Choosing an efficient grid is very difficult for multi-dimensional state spaces, and oftentimes expensive computations must be done at each point. For the original Gaussian sum filter, a weighted sum of Gaussian density functions approximates the pdf but suffers at the update step for the individual component weight selections. In order to improve upon the original Gaussian sum filter, Ref. [2] introduces a weight update approach at the filter propagation stage instead of the measurement update stage. This weight update is performed by minimizing the integral square difference between the true forecast pdf and its Gaussian sum approximation. By adaptively updating each component weight during the nonlinear propagation stage an approximation of the true pdf can be successfully reconstructed. Particle filtering (PF) methods have gained popularity recently for solving nonlinear estimation problems due to their straightforward approach and the processing capabilities mentioned above. The basic concept behind PF is to represent any pdf as a set of random samples. As the number of samples increases, they will theoretically converge to the exact, equivalent representation of the desired pdf. When the estimated qth moment is needed, the samples are used for its construction allowing further analysis of the pdf characteristics. However, filter performance deteriorates as the dimension of the state vector increases. To overcome this problem Ref. [5] applies a marginalization technique for PF methods, decreasing complexity of the system to one linear and another nonlinear state estimation problem. The marginalization theory was originally developed by Rao and Blackwell independently. According to Ref. [6] it improves any given estimator under every convex loss function. The improvement comes from calculating a conditional expected value, often involving integrating out a supportive statistic. In other words, Rao-Blackwellization allows for smaller but separate computations to be carried out while reaching the main objective of the estimator. In the case of improving an estimator's variance, any supporting statistic can be removed and its variance determined. Next, any other information that dependents on the supporting statistic is found along with its respective variance. A new approach is developed here by utilizing the strengths of the adaptive Gaussian sum propagation in Ref. [2] and a marginalization approach used for PF methods found in Ref. [7]. In the following sections a modified filtering approach is presented based on a special state-space model within nonlinear systems to reduce the dimensionality of the optimization problem in Ref. [2]. First, the adaptive Gaussian sum propagation is explained and then the new marginalized adaptive Gaussian sum propagation is derived. Finally, an example simulation is presented.

state estimation↗

PINN surrogate of Li-ion battery models for parameter inference, Part II: Regularization and application of the pseudo-2D model

Bayesian parameter inference is useful to improve Li-ion battery diagnostics and can help formulate battery aging models. However, it is computationally intensive and cannot be easily repeated for multiple cycles, multiple operating conditions, or multiple replicate cells. To reduce the computational cost of Bayesian calibration, numerical solvers for physics-based models can be replaced with faster surrogates. A physics-informed neural network (PINN) is developed as a surrogate for the pseudo-2D (P2D) battery model calibration. For the P2D surrogate, additional training regularization was needed as compared to the PINN single-particle model (SPM) developed in Part I. Both the PINN SPM and P2D surrogate models are exercised for parameter inference and compared to data obtained from a direct numerical solution of the governing equations. A parameter inference study highlights the ability to use these PINNs to calibrate scaling parameters for the cathode Li diffusion and the anode exchange current density. By realizing computational speed-ups of ~2250x for the P2D model, as compared to using standard integrating methods, the PINN surrogates enable rapid state-of-health diagnostics. Finally, in the low-data availability scenario, the testing error was estimated to ~2 mV for the SPM surrogate and ~10 mV for the P2D surrogate which could be mitigated with additional data.

25 ENERGY STORAGE↗

Bayesian optimization to design a novel x-ray shaping device

In radiation therapy, x-ray dose must be precisely sculpted to the tumor, while simultaneously avoiding surrounding organs at risk. This requires modulation of x-ray intensity in space and/or time. Typically, this is achieved using a multi leaf collimator (MLC) - a complex mechatronic device comprising over one hundred individually powered tungsten ‘leaves’ that move in or out of the radiation field as required. Here, an all-electronic x-ray collimation concept with no moving parts is presented, termed “SPHINX”: Scanning Pencil-beam High-speed Intensity-modulated X-ray source. SPHINX utilizes a spatially distributed bremsstrahlung target and collimator array in conjunction with magnetic scanning of a high energy electron beam to generate a plurality of small x-ray “beamlets.” A simulation framework was developed in Topas Monte Carlo incorporating a phase space electron source, transport through user defined magnetic fields, bremsstrahlung x-ray production, transport through a SPHINX collimator, and dose in water. This framework was completely parametric, meaning a simulation could be built and run for any supplied geometric parameters. This functionality was coupled with Bayesian optimization to find the best parameter set based on an objective function which included terms to maximize dose rate for a user defined beamlet width while constraining inter-channel cross talk and electron contamination. Designs for beamlet widths of 5, 7, and 10 mm 2 were generated. Each optimization was run for 300 iterations and took approximately 40 h on a 24-core computer. For the optimized 7-mm model, a simulation of all beamlets in water was carried out including a linear scanning magnet calibration simulation. Finally, a back-of-envelope dose rate formalism was developed and used to estimate dose rate under various conditions. The optimized 5–, 7–, and 10-mm models had beamlet widths of 5.1 , 7.2 , and 10.1 mm 2 and dose rates of 3574, 6351, and 10 015 Gy/C, respectively. The reduction in dose rate for smaller beamlet widths is a result of both increased collimation and source occlusion. For the simulation of all beamlets in water, the scanning magnet calibration reduced the offset between the collimator channels and beam centroids from 2.9 ±1.9 mm to 0.01 ±0.03 mm. A slight reduction in dose rate of approximately 2% per degree of scanning angle was observed. Based on a back-of-envelope dose rate formalism, SPHINX in conjunction with next-generation linear accelerators has the potential to achieve substantially higher dose rates than conventional MLC-based delivery, with delivery of an intensity modulated 100 x 100 mm 2 field achievable in 0.9 to 10.6 s depending on the beamlet widths used. Bayesian optimization was coupled with Monte Carlo modeling to generate SPHINX geometries for various beamlet widths. A complete Monte Carlo simulation for one of these designs was developed, including electron beam transport of all beamlets through scanning magnets, x-ray production and collimation, and dose in water. These results demonstrate that SPHINX is a promising candidate for sculpting radiation dose with no moving parts, and has the potential to vastly improve both the speed and robustness of radiotherapy delivery. A multi-beam SPHINX system may be a candidate for delivering magavoltage FLASH RT in humans.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Diagnostics: Chapter 8 of the special issue: on the path to tokamak burning plasma operation

This chapter presents the activity conducted by the ITPA topical group (TG) on Diagnostics over about the last 15 years. Following a general introduction of the ITER Diagnostics led by their measurement roles, the document is organized in several subchapters detailing the design support, research and development activity conducted by each of the specialist working groups (WGs) of the TG. Please note that the magnetic diagnostics were supported at the TG without a specific WG. Their status is included in the general introduction. In the following some highlights of the subchapter’s contents are provided. Recent advances in ITER first wall (FW) diagnostics for the measurements of plasma-metallic wall interaction in support of the ITER research plan are reported. An InfraRed imaging Video Bolometer for ITER has been developed and tested on several tokamaks to measure the radiated power loss. A laser-induced breakdown spectroscopy (LIBS) technique which utilizes a pulsed laser beam to ablate locally by forming a crater, will measure local tritium inventory in the FW material. Real-time Residual Gas Analyzers will measure the neutral gas composition in a divertor port and an equatorial port during plasma operation. Due to the full metallic FW environment, the plasma-wall interaction in ITER will face several challenges such as the compromised radiated power and divertor heat flux measurements by reflection. Ray tracing and analysis codes have been developed to eliminate and correct the effects of reflection in the measurements. The characteristics of the reflecting surfaces depending on the roughness and angle of the incidence have been measured by dedicated experiments, and the results were applied to the reflection elimination. For the measurement of the metallic impurity radiation induced by eroded metallic atoms, a vacuum ultraviolet spectrometer has been developed and tested. An extensive thermonuclear diagnostic suite will be required to support the operation of ITER and the planned experimental program for future burning plasma experiments. Due to the harsh environmental conditions, the implementation of diagnostic systems in ITER is a major challenge. These conditions include high levels of neutron and gamma fluxes, neutron heating, particle bombardment. Therefore, the selection and design of diagnostic systems must take into account a number of phenomena previously unseen in diagnostic design. For this reason, the measurement of neutrons and confined or lost fast ions, with particular emphasis on alpha particles, is critical to ITER. The diagnostics associated with these measurements will be important for future plasma-burning experiments at ITER. The high neutron emission and very large plasma size in ITER make neutron diagnostics the main diagnostic method used to measure plasma parameters such as fusion power, fusion power density, ion temperature, energy of fast ions and their spatial distributions in the plasma core. Active spectroscopy techniques are methods where a neutral particle beam is injected into the plasma and information on plasma parameters is extracted from the measurement of line emission resulting from the beam-plasma interaction, either by plasma ions or by beam atoms. Spatial localization is achieved by crossing the beamline and multiple observation lines. The ITER plasma will be a high temperature, moderately dense, fully ionized collisional plasma. The plasma facing surfaces are principally metallic being fashioned from beryllium or tungsten but many other elements, arising from either structural or from operational needs, may enter this plasma. The energy range of the emitted photons range from meV (infra-red) to multi keV (x-rays) and originate from all areas of the plasma volume. The primary role of passive emission diagnostics is to identify what is in the plasma from spectral signatures. Extracting quantitative information from these measurements such as impurity content, ion temperature, rotation, degree of detachment and radiated power depends on calibrated instruments, a physics model of the atomic and molecular processes and plasma transport and an analysis workflow that takes into account environmental effects such as reflections. The particular needs for ITER have prompted a multi-machine, many-year effort to address all these aspects and this chapter reviews the work on diagnostic design, experiments and new analysis techniques. An overview of the laser diagnostics to be implemented on ITER is also provided in this paper. This includes descriptions of the Thomson scattering in the core, edge and divertor regions, polarimetry and interferometry diagnostics used for measuring plasma density and also measurements of helium density in the divertor using Laser Induced Flourescence. Techniques which can allow improvements on current measurements are also addressed in particular expanding poloidal polarimetry measurements to measure field fluctuations and proposed use of dispersion interferometery which has a number of advantages over existing methods. This paper identifies particular areas where further research and testing on existing tokamaks is useful even at this advanced stage to inform the design of diagnostics for ITER. Outstanding areas of concern for the implementation of laser diagnostics, in particular with a view to reliable operation are identified. An overview of the latest developments of microwave diagnostic systems and techniques is given. The primary focus is the contributions for ITER—the next step burning plasma experiment—which is supplemented by describing recent progress of techniques applicable for fusion experiments beyond ITER. The contributions are intentionally kept concise, and are being supplemented by a rich list of references for further studies. Radiation induced effects are receiving continuous and well-deserved attention of the ITER diagnostic community and they are in many cases one of the primary design drivers of the ITER diagnostic systems. The paper summarizes recent progress in this area focusing primarily on the ITER diagnostics but in some cases provides also outlook for the possible solutions for even more demanding radiation environment of fusion reactors beyond ITER. Despite advancements in the area of modeling and simulation of various radiation induced effects, experimental testing in a nuclear environment as close as possible to the target one is still seen as unavoidable for proper qualification of particular diagnostic functional elements. Recent advancement within three diagnostic areas: optical diagnostics, magnetics and bolometers is covered. Encouraging results on qualification of silica glass vacuum window assemblies are presented. In the area of magnetic sensors, progress of irradiation tests performed on ITER in-vessel LTCC inductive sensors is presented with outlook for novel technological approaches to inductive sensors utilizing thick printing and photolithography technologies being highlighted. Summary of advancements in the area of steady state magnetic field sensors based on Hall effect is given. New results of neutron irradiation test of the ITER borosilicate glass inserts for vacuum electrical feedthroughs are summarized finding negligible swelling at target level of neutron fluence. Off-line irradiation tests of fiber optic current sensors for plasma current measurement demonstrated that both for gamma doses up to 5 MGy and a total neutron fluence up to 10 15 cm −2 , radiation induced changes are still compatible with required measurement accuracy on ITER. The ITER bolometers are given as an example how considering radiation effects may influence the diagnostic design. Finally, outlook for future main R&D directions is outlined. All optical and laser-based diagnostics in ITER will be using mirrors to guide plasma radiation toward detectors, cameras and sensors. In the hostile plasma, radiation and particle environment the optical characteristics of diagnostic mirrors will degrade directly affecting the entire performance of involved diagnostic systems. An assessment of factors affecting mirror performance is provided. Among the prime adverse factors are deposition of plasma impurities, sputtering of mirror surface and steam ingress in the vicinity of mirrors. Within the International Tokamak Physics Activity with active support by ITER central team and domestic agencies, the structured research and development (R&D) program on mitigation of risks for diagnostic mirrors is underway. Within this program the mirror material development, the passive mitigation of mirror degradation by using diagnostic ducts and shutters along with an active mirror recovery program comprising the in-situ mirror cleaning and calibration is underway. Recent developments in diagnostic mirror R&D are described in this Chapter along with an example of their implementation of R&D solutions in ITER Infrared Thermography diagnostic. An assessment of still open engineering and physics questions, considerations on mirror risks during an early phase of ITER operation are given along with an overview of diagnostic mirror evolution in the late ITER operation stage toward the demonstration fusion power plant. Several crucial areas of diagnostic R&D outlined in ITER Research Plan are addressed. The basic control groups in a fusion reactor can be broken-down in five categories: (1) plasma position, magnetic configuration, and plasma current control, (2) profile control and confinement optimization, (3) MHD control and suppression, (4) edge dissipation control, radiation and plasma exhaust control and (5) break-down optimization. These categories are coupled via the physics (a control action in one domain will affect the other domains) and via shared actuators (e.g. ECRH for impurity accumulation avoidance, current density distribution control and MHD suppression). Consequently, a supervisory control system should determine the priority of the various control tasks, their couplings, and the interfaces with the safety and interlock system. For the systematic development of the various controllers taking the complexity of the plasma and the control system into account, a model-based approach is required. A short historical overview is given of the developments in systems and control theory and control engineering with special emphasis on those developments that are most relevant for Nuclear Fusion research and operation. An overview is given of the state of the field of fusion plasma control for the control categories. It will be shown how synthetic diagnostics are being developed in ITER and how they are used in diagnostic design and design validation and how they can be in model-based controller synthesis using relatively simple models. In modern control methods, multiple diagnostics are used to constrain relatively simple models. The constrained models provide an estimate for the state. This opens the route to state controllers, such as model predictive control. A major challenge in nuclear fusion research is the coherent combination of data from heterogeneous diagnostics and modeling codes for machine control and safety as well as physics studies. Measured data from different diagnostics often provide information about the same subset of physical parameters. Additionally, information provided by some diagnostics might be needed for the analysis of other diagnostics. A joint analysis of complementary and redundant data allows, e.g. to improve the reliability of parameter estimation, to increase the spatial and temporal resolution of profiles, to obtain synergistic effects, to consider diagnostics interdependencies and to find and resolve data inconsistencies. Physics-based modeling and parameter relationships provide additional information improving the treatment of ill-posed inversion problems. A coherent combination of all kind of available information within a probabilistic framework allows for improved data analysis results. The concept of integrated data analysis (IDA) in the framework of Bayesian probability theory is outlined and contrasted with conventional data analysis. Components of the probabilistic approach are summarized and specific ingredients beneficial for data analysis at fusion devices are discussed.

ITER↗

A Bayesian method for inferring transmission chains in a partially observed epidemic.

We present a Bayesian approach for estimating transmission chains and rates in the Abakaliki smallpox epidemic of 1967. The epidemic affected 30 individuals in a community of 74; only the dates of appearance of symptoms were recorded. Our model assumes stochastic transmission of the infections over a social network. Distinct binomial random graphs model intra- and inter-compound social connections, while disease transmission over each link is treated as a Poisson process. Link probabilities and rate parameters are objects of inference. Dates of infection and recovery comprise the remaining unknowns. Distributions for smallpox incubation and recovery periods are obtained from historical data. Using Markov chain Monte Carlo, we explore the joint posterior distribution of the scalar parameters and provide an expected connectivity pattern for the social graph and infection pathway.

59 BASIC BIOLOGICAL SCIENCES↗

What’s Driving Uncertainty? The Model or the Model Parameters (What’s Driving Uncertainty? The influences of model and model parameters in data analysis)

Here, one of the substantial improvements to the practice of data analysis in recent decades is the change from reporting just a point estimate for a parameter or characteristic, to now including a summary of uncertainty for that estimate. Understanding the precision of the estimate for the quantity of interest provides better understanding of what to expect and how well we are able to predict future behavior from the process. For example, when we report a sample average as an estimate of the population mean, it is good practice to also provide a confidence interval (or credible interval, if you are doing a Bayesian analysis) to accompany that summary. This helps to calibrate what ranges of values are reasonable given the variability observed in the sample and the amount of data that were included in producing the summary.

97 MATHEMATICS AND COMPUTING↗

Progress in Accurate Chemical Kinetic Modeling, Simulations, and Parameter Estimation for Heterogeneous Catalysis

Chemical kinetic modeling in heterogeneous catalysis is gaining ground in its ability to provide qualitatively or even quantitatively accurate prediction of real-world behavior because of new advances in the physical and chemical representations of catalytic systems, estimation of relevant kinetic parameters, and capabilities in kinetic modeling. This Perspective chronicles current trends and future areas of advancement in chemical kinetic modeling, simulation, and parameter estimation: ranging from elementary step calculations to multiscale modeling to the role of advanced statistical methods for incorporating uncertainties in predictions. Multiple new or growing methodologies are covered, examples are provided, and forward-looking topics for advancement are noted.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Using PyBioNetFit to leverage qualitative and quantitative data in biological model parameterization and uncertainty quantification

Data generated in studies of cellular regulatory systems are often qualitative. For example, measurements of signaling readouts in the presence and absence of mutations may reveal a rank ordering of responses across conditions but not the precise extents of mutation-induced differences. Qualitative data are often ignored by mathematical modelers or are considered in an ad hoc manner, as in the study of Kocieniewski and Lipniacki (2013) [Phys Biol 10: 035006], which was focused on the roles of MEK isoforms in ERK activation. In this earlier study, model parameter values were tuned manually to obtain consistency with a combination of qualitative and quantitative data. This approach is not reproducible, nor does it provide insights into parametric or prediction uncertainties. Here, starting from the same data and the same ordinary differential equation (ODE) model structure, we generate formalized statements of qualitative observations, making these observations more reusable, and we improve the model parameterization procedure by applying a systematic and automated approach enabled by the software package PyBioNetFit. We also demonstrate uncertainty quantification (UQ), which was absent in the original study. Our results show that PyBioNetFit enables qualitative data to be leveraged, together with quantitative data, in parameterization of systems biology models and facilitates UQ. These capabilities are important for reliable estimation of model parameters and model analyses in studies of cellular regulatory systems and reproducibility.

59 BASIC BIOLOGICAL SCIENCES↗

Bayesian approach to model-based extrapolation of nuclear observables

Here, we considered 10 global models based on nuclear density functional theory with realistic energy density functionals as well as two more phenomenological mass models. The emulators of two-neutron separation energy residuals and Bayesian confidence intervals defining theoretical error bars were constructed using Bayesian Gaussian processes and Bayesian neural networks. By establishing statistical methodology and parameters, we carried out extrapolations toward the two-neutron dripline. While both Gaussian processes (GP) and Bayesian neural networks reduce the root-mean-square (rms) deviation from experiment significantly, GP offers a better and much more stable performance. The increase in the predictive power of microscopic models aided by the statistical treatment is quite astonishing: The resulting rms deviations from experiment on the testing dataset are similar to those of more phenomenological models. The estimated credibility intervals on predictions make it possible to evaluate predictive power of individual models and also make quantified predictions using groups of models. The proposed robust statistical approach to extrapolation of nuclear model results can be useful for assessing the impact of current and future experiments in the context of model developments. The new Bayesian capability to evaluate residuals is also expected to impact research in the domains where experiments are currently impossible, for instance, in simulations of the astrophysical r process.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Castagna, M., M. W. Becker, and A. Bellin (2011), Joint estimation of transmissivity and storativity in a bedrock fracture, Water Resour. Res., 47, W09504, doi:10.1029/2010WR009262.

The spatial variability of transmissivity (T) and storativity (S) in a sandstone bedding plane fracture was investigated through field and numerical hydraulic tomography experiments. Cross-hole pumping tests were conducted in a single subhorizontal bedrock fracture, thereby constraining the problem to two dimensions. A Bayesian method implementing pilot points was used to invert the drawdown, under the hypothesis that T and S are independent random space functions, where integral scale, mean, and variance of the random fields were parameters of inversion in addition to pilot point values. An ensemble of 20 Monte Carlo realizations was created for each model scenario. Inversion of the measured cross-hole drawdown resulted in spatially variable T and S fields. To determine the accuracy of the method, a suite of synthetic inversions modeled after the field site were also conducted. The synthetic experiments demonstrate that the assumed spatial structure of S influences the accuracy of both the T and S inversions. When the S field is spatially heterogeneous and is assumed to be heterogeneous in the inversion, a consistent representation of the T and S fields is obtained. When the S field is spatially heterogeneous but is assumed to be homogeneous in the inversion, a consistent representation of the T field is still obtained, but the S field is entirely misrepresented; if the S field is actually homogeneous but assumed to be heterogeneous, a poor representation of the T and S fields is obtained along with high uncertainty in the inversion statistics of confidence.

54 ENVIRONMENTAL SCIENCES↗