Search NASA⌕ Search

SEARCH · Search NASA

Results for “Beam Distribution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

High-flux source of low-energy neutral beams using reflection of ions from metals

Reflection of low-energy ions from surfaces can be applied as a method of producing high-flux beams of low-energy neutral particles, and is an important effect in several areas of plasma technology, such as in the edge region of fusion devices. We have developed a beam source based on acceleration and reflection of ions from a magnetically confined coaxial RF plasma source. The beam provides a large enough flux to allow the energy distribution of the reflected neutrals to be measured despite the inefficiency of detection, by means of an electrostatic cylindrical mirror analyzer coupled with a quadrupole mass spectrometer. Energy distributions have been measured for oxygen, nitrogen, and inert gas ions incident with from 15 to 70 eV reflected from amorphous metal surfaces of several compositions. For ions of lighter atomic mass than the reflecting metal, reflected beams have peaked energy distributions; beams with the peak at 4-32 eV have been measured. The energy and mass dependences of the energy distributions as well as measurements of absolute flux, and angular distribution and divergence are reported. Applications of the neutral beams produced are described.

Cuthbertson, John W.↗

Exact relativistic kinetic theory of the full unstable spectrum of an electron-beam-plasma system with Maxwell-Juettner distribution functions

Following a recent Letter by Bret et al. [Phys. Rev. Lett. 100, 205008 (2008)], we present a detailed report of the entire unstable k spectrum of a relativistic collisionless beam-plasma system within a fully kinetic framework. In contrast to a number of previously published studies, our linear analysis makes use of smooth momentum distribution functions of the Maxwell-Juettner form. The three competing classes of instabilities, namely, two-stream, filamentation, and oblique modes, are dealt with in a unified manner, no approximation being made regarding the beam-plasma densities, temperatures, and drift energies. We investigate the hierarchy between the competing modes, paying particular attention to the relatively poorly known quasielectrostatic oblique modes in the regime where they govern the system. The properties of the fastest growing oblique modes are examined in terms of the system parameters and compared to those of the dominant two-stream and filamentation modes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Optical distributed sensing and computation for a proposed flexible beam experiment

A new technology is being developed that supports distributed sensing and computation wherein crystal mediums are used with real-time holography to gather images that contain vibration and instantaneous geometry data for a spacecraft. Optical computation techniques are employed to process the image data and to compute commands to actuators located on the spacecraft. This paper presents an integrated sensor/processor design for an experiment to demonstrate this technology. A performance estimate for the design is presented in terms of the optical spatial bandwidth of the imaging system, as opposed to the temporal bandwidth. The advantages of an integrated optical sensor/processor relative to control of large spacecraft are addressed.

Welch, S. S.↗

The effect of voxel size on dose distribution in Varian Clinac iX 6 MV photon beam using Monte Carlo simulation

Recently, Monte Carlo (MC) calculation method has reported as the most accurate method of predicting dose distributions in radiotherapy. The MC code system (especially DOSXYZnrc) has been used to investigate the different voxel (volume elements) sizes effect on the accuracy of dose distributions. To investigate this effect on dosimetry parameters, calculations were made with three different voxel sizes. The effects were investigated with dose distribution calculations for seven voxel sizes: 1 × 1 × 0.1 cm{sup 3}, 1 × 1 × 0.5 cm{sup 3}, and 1 × 1 × 0.8 cm{sup 3}. The 1 × 10{sup 9} histories were simulated in order to get statistical uncertainties of 2%. This simulation takes about 9-10 hours to complete. Measurements are made with field sizes 10 × 10 cm2 for the 6 MV photon beams with Gaussian intensity distribution FWHM 0.1 cm and SSD 100.1 cm. MC simulated and measured dose distributions in a water phantom. The output of this simulation i.e. the percent depth dose and dose profile in d{sub max} from the three sets of calculations are presented and comparisons are made with the experiment data from TTSH (Tan Tock Seng Hospital, Singapore) in 0-5 cm depth. Dose that scored in voxels is a volume averaged estimate of the dose at the center of a voxel. The results in this study show that the difference between Monte Carlo simulation and experiment data depend on the voxel size both for percent depth dose (PDD) and profile dose. PDD scan on Z axis (depth) of water phantom, the big difference obtain in the voxel size 1 × 1 × 0.8 cm{sup 3} about 17%. In this study, the profile dose focused on high gradient dose area. Profile dose scan on Y axis and the big difference get in the voxel size 1 × 1 × 0.1 cm{sup 3} about 12%. This study demonstrated that the arrange voxel in Monte Carlo simulation becomes important.

61 RADIATION PROTECTION AND DOSIMETRY↗

A New Method of Selective Laser Cladding

A new approach to selective laser cladding using conical laser beams has been elaborated. The initial round laser beam is divided into two or more circular beams with regulated distribution of the laser power between them. The circular beams are converted into conical beams that are focused separately on the surface and on different areas of the deposited material for their efficient heating. The delivery of laser energy into the powder stream is very effective because it provides a complete uniform absorption of laser energy in a dense powder stream (10{sup 4}–10{sup 6} cm{sup –3}). Under wire deposition, substrate heating reduces residual stresses due to temperature gradients and compensates for heat loss from the deposition zone by thermal conduction. The required power density for melt contact formation is significantly reduced.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Optimization of a charge-state analyzer for electron cyclotron resonance ion source beams

A detailed experimental and simulation study of the extraction of a 24 keV He{sup +} beam from an ECR ion source and the subsequent beam transport through an analyzing magnet is presented. We find that such a slow ion beam is very sensitive to space-charge forces, but also that the neutralization of the beam's space charge by secondary electrons is virtually complete for beam currents up to at least 0.5 mA. The beam emittance directly behind the extraction system is 65 {pi} mm mrad and is determined by the fact that the ion beam is extracted in the strong magnetic fringe field of the ion source. The relatively large emittance of the beam and its non-paraxiality lead, in combination with a relatively small magnet gap, to significant beam losses and a five-fold increase of the effective beam emittance during its transport through the analyzing magnet. The calculated beam profile and phase-space distributions in the image plane of the analyzing magnet agree well with measurements. The kinematic and magnet aberrations have been studied using the calculated second-order transfer map of the analyzing magnet, with which we can reproduce the phase-space distributions of the ion beam behind the analyzing magnet. Using the transfer map and trajectory calculations we have worked out an aberration compensation scheme based on the addition of compensating hexapole components to the main dipole field by modifying the shape of the poles. The simulations predict that by compensating the kinematic and geometric aberrations in this way and enlarging the pole gap the overall beam transport efficiency can be increased from 16% to 45%.

43 PARTICLE ACCELERATORS↗

Measurements of the effective electron density in an electron beam ion trap using extreme ultraviolet spectra and optical imaging

In an electron beam ion trap (EBIT), the ions are not confined to the electron beam, but rather oscillate in and out of the beam. As a result, the ions do not continuously experience the full density of the electron beam. To determine the effective electron density, n e,eff , experienced by the ions, the electron beam size, the nominal electron density n e , and the ion distribution around the beam, i.e., the so-called ion cloud, must be measured. We use imaging techniques in the extreme ultraviolet (EUV) and optical to determine these. The electron beam width is measured using 3 d → 3 p emission from Fe xii and xiii between 185 and 205 Å. These transitions are fast and the EUV emission occurs only within the electron beam. The measured spatial emission profile and variable electron current yield a nominal electron density range of n e ~ 10 11 –10 13 cm –3 . We determine the size of the ion cloud using optical emission from metastable levels of ions with radiative lifetimes longer than the ion orbital periods. Here, the resulting emission maps out the spatial distribution of the ion cloud. We find a typical electron beam radius of ~60 μm and an ion cloud radius of ~300 μ m. These yield a spatially averaged effective electron density, ne,eff, experienced by the ions in EBIT spanning ~ 5 × 10 9 –5 × 10 11 cm –3 .

47 OTHER INSTRUMENTATION↗

Valence Electron Distributions from Sub-Angstrom Convergent Beam Electron Diffraction

Modern aberration-corrected scanning transmission electron microscopes can acquire four-dimensional data sets (“4D STEM”) by recording convergent beam electron diffraction (CBED) patterns, using precisely positioned, sub-angstrom probes. Here, we demonstrate that these patterns can probe the site symmetry, atomic displacements, and valence electron distributions at individual atomic columns. To this end, 4D STEM CBED patterns were acquired from SrTiO 3 single crystals and compared with patterns calculated using scattering potentials derived from density functional theory. Here, we show that an aspherical valence electron charge build-up at the oxygen sites causes intensity asymmetries in the low-angle scattering portion of the patterns. Using strained SrTiO 3 films containing subtle polar displacements within nanometer-sized domains, it is shown that the high-angle scattering portion in each pattern is sensitive to atomic displacements.

36 MATERIALS SCIENCE↗

Depth-dose relations for heavy ion beams

Radiation transport of heavy ions in matter is of interest to radiological protection in space and high-altitude aircraft. In addition, heavy ion beams are expected to be of advantage in radiotherapy since their characteristic Bragg curve allows a relative reduction of the dose in reaching a tumor site and the near elimination of exposure beyond the tumor region as the beam exits the body. Furthermore, the radioresistance of tumorous cells due to their hypoxic state may be reduced or eliminated by the high specific ionization of heavy ion beams. The depth-dose distribution of heavy ion beams consists of energy deposited by the attenuated primary beam with its characteristic Bragg curve and a relatively unstructured background due to secondary radiations produced in nuclear reactions. As the ion mass increases, the secondary contribution becomes more structured and may add significantly to the Bragg peak of the primary ions. The result for heavy ions (z greater than 20) is a greatly broadened Bragg peak region, especially in comparison to straggling effects, which may prove to be of importance in radiotherapy and biomedical research.

Wilson, J. W.↗

Re-Analysis of DARHT Axis 2 S4 Magnet Sweep Measurements

The Dual-Axis Radiographic Hydrodynamic Test (DARHT) facility provides flash radiography capabilities using two electron Linear Induction Accelerators (LIA’s). Understanding fundamental properties of the electron beams is essential to optimizing spot size and dose for radiography. This work describes distribution measurements of a single-kicked electron beam (16.5MeV, 1.7kA, 60ns) at a location downstream at imaging station C on DARHT Axis 2. The beam at station C is focused by the S4 solenoid located upstream. The beam distribution is measured by imaging optical transition radiation (OTR) from electrons striking a 51-µm thick titanium foil. This data and analysis were originally published by Ekdahl. The results here are a re-analysis of the asymmetric halo emittance contribution as compared to the emittance resulting from the FWHM of the distribution. This is accomplished using xtr2 fits to the data which include non-linear magnetic field effects in S4. Also examined are the calculated S4 spherical aberration contributions to the emittance using xtr.

43 PARTICLE ACCELERATORS↗

EB_Profiler

EB_Profiler, v2.2 is a LabVIEW program which uses computed tomography to determine the power distribution in the beams of electron beam welders. It requires that the National Instruments LabVIEW Run-Time Engine be installed. The program takes in beam profile data from a data acquisition device or from a data file. Beam parameters necessary for calculations are entered by the user or automatically extracted from header information in the data file. The result is a two-dimensional reconstruction of the power distribution in the beam.

Teruya, Alan↗

Attacking a practical quantum-key-distribution system with wavelength-dependent beam-splitter and multiwavelength sources

It is well known that the unconditional security of quantum-key distribution (QKD) can be guaranteed by quantum mechanics. However, practical QKD systems have some imperfections, which can be controlled by the eavesdropper to attack the secret key. With current experimental technology, a realistic beam splitter, made by fused biconical technology, has a wavelength-dependent property. Based on this fatal security loophole, we propose a wavelength-dependent attacking protocol, which can be applied to all practical QKD systems with passive state modulation. Moreover, we experimentally attack a practical polarization encoding QKD system to obtain all the secret key information at the cost of only increasing the quantum bit error rate from 1.3 to 1.4%.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Area-selected Ion Milling for Reflection Wavefront Error Correction of Soft X-ray Multilayer Mirrors

For accurate reflection wavefront error correction of imaging soft X-ray multilayer mirrors, a period-by-period ion milling system was developed. A stable and homogenized radial distribution of ion beam was realized for an ion milling over a whole area of 100 mm-wide multilayer. To demonstrate the wavefront error correction principle, a dielectric multilayer mirror for visible light was locally milled by our system. Wavefront as measured by a phase shifting interferometer showed the reflection phase of local milling multilayer advanced. Area-selected ion millings with mask templates made of Mo and Si, and by photoresist contact masks were carried out. Although striped patterns generated by the difference of spectroscopic reflectance between Mo and Si were observed at peripherals of milling area when templates were used, a clear and sharp edge pattern was obtained with contact mask. Soft X-ray reflectance of a Mo/Si multilayer milled with photoresist contact mask showed good feasibility of precise wavefront error correction of multilayers. These results proved our phase correction method is promising and practical for the 0.1 nm-period correction of soft X-ray multilayer mirror.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Energy Characterization of the UMD Electron Accelerator

Multiple different groups at Los Alamos National Laboratory have a cited interest in understanding the effects of ionizing radiation in materials. Of especial interest to the ISR division is understanding the effects in materials that are used in the space environment, where radiation is omnipresent and impossible to fully shield from. Development is under way to simulate the effects of radiation damage in detectors and electronics, primarily with particle transport codes such as Geant4 and RAMPART, a code that provides a user friendly interface to Geant4. However, these simulations need benchmarking to experimental tests, some of which have been performed at a variety of small electron accelerator facilities. One of these facilities is the Linear Electron Accelerator at the University of Maryland Radiation Facilities. This facility can provide electron beams on the order of 100 mA delivered in tight macropulse bunches, which allows for experiments where the behavior of electronics is monitored as a function of pulse number. While the beam rates per macropulse of this accelerator is monitored during an experiment via a current pick-off connected to a large graphite beamstop, the energy distribution of this electron beam is not measured during the experiment and has not been well characterized. The energy distribution of the beam is pertinent for these types of experiments, since dose is directly related to energy deposited in a medium. Further, these experiments are performed in open air and sample placement in the room can dictate what dose rate they receive per macropulse. We have created simulated dosemaps for the UMD vault room, but these simulations assume a given energy of the beam, both for calculating the dose and to simulate how much the beam diverges in the air. There have been two attempts now to characterize this accelerator beam energy with a plate type spectrometer, including the most recent experiment earlier this year to quantify the beam energy distribution. These results will also be compared to a dosimetry experiment performed by collaborators at the UMD facility, the details of which are described in Reference. Understanding the electron beam energy is important for future experiments, because the energy directly impacts the dose and radiation damage given to a sample and is important for properly simulating the electron beam when comparing simulation to experiment.

43 PARTICLE ACCELERATORS↗

Simulation of Electron-Beam Irradiation of Skin Tissue Model

Monte Carlo simulation of electrons stopping in liquid water was used to model the penetration and dose distribution of electron beams incident on the full-thickness EpiDermTM skin model (MatTek, Ashland, VA). This 3D tissue model has a fully developed basement membrane separating an epidermal layer of keratinocytes in various stages of differentiation from a dermal layer of fibroblast embedded in collagen. The simulations were motivated by a desire to selectively expose the epidermal layer to low linear-energy-transfer (LET) radiation in the presence of a non-irradiated dermal layer. Using the variable energy electron microbeam at the Pacific Northwest National Laboratory (PNNL) as a model of device characteristics and irradiation geometry, we find that at the highest beam energy available (90 keV), the estimated 90th percentile of penetration remains in the epidermal layer. To investigate the depth-dose distribution, we calculated lineal energy spectra for 10um thick layers near the 10th, 50th, and 90th percentile of penetration by the 90 keV electron beam. Biphasic spectra showed an increasing component of "stoppers" with increasing depth. Despite changes in the lineal energy spectra, the main effect on dose deposition with increasing depth is the screening effect of tissue above the layer of interest.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Spatial evolution of an ion beam created by a geometrically expanding low-pressure argon plasma

The spatial distribution of an ion beam--created at the interface of a small diameter plasma source and much larger diameter diffusion chamber--is studied in a low-pressure inductively coupled plasma using a retarding field energy analyzer. It is found that the ion beam density decays axially and radially in the diffusion chamber following the expansion of the plasma from the source region. The radial distribution of the ion beam indicates that the acceleration region has a convex shape and is located just outside the source exit, giving rise to a hemispherical plasma expansion into the diffusion chamber.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Optical transition radiation used in the diagnostic of low energy and low current electron beams in particle accelerators

Optical transition radiation (OTR) plays an important role in beam diagnostics for high energy particle accelerators. Its linear intensity with beam current is a great advantage as compared to fluorescent screens, which are subject to saturation. Moreover, the measurement of the angular distribution of the emitted radiation enables the determination of many beam parameters in a single observation point. However, few works deals with the application of OTR to monitor low energy beams. In this work we describe the design of an OTR based beam monitor used to measure the transverse beam charge distribution of the 1.9-MeV electron beam of the linac injector of the IFUSP microtron using a standard vision machine camera. The average beam current in pulsed operation mode is of the order of tens of nano-Amps. Low energy and low beam current make OTR observation difficult. To improve sensitivity, the beam incidence angle on the target was chosen to maximize the photon flux in the camera field-of-view. Measurements that assess OTR observation (linearity with beam current, polarization, and spectrum shape) are presented, as well as a typical 1.9-MeV electron beam charge distribution obtained from OTR. Some aspects of emittance measurement using this device are also discussed.

43 PARTICLE ACCELERATORS↗

Definition of the Spatial Resolution of X-Ray Microanalysis in Thin Foils

The spatial resolution of X-ray microanalysis in thin foils is defined in terms of the incident electron beam diameter and the average beam broadening. The beam diameter is defined as the full width tenth maximum of a Gaussian intensity distribution. The spatial resolution is calculated by a convolution of the beam diameter and the average beam broadening. This definition of the spatial resolution can be related simply to experimental measurements of composition profiles across interphase interfaces. Monte Carlo calculations using a high-speed parallel supercomputer show good agreement with this definition of the spatial resolution and calculations based on this definition. The agreement is good over a range of specimen thicknesses and atomic number, but is poor when excessive beam tailing distorts the assumed Gaussian electron intensity distributions. Beam tailing occurs in low-Z materials because of fast secondary electrons and in high-Z materials because of plural scattering.

Williams, D. B.↗