Search NASA⌕ Search

SEARCH · Search NASA

Results for “Building performance simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Establishing a Comprehensive Wind Energy Program

This project was directed at establishing a comprehensive wind energy program in Indiana, including both educational and research components. A graduate/undergraduate course ME-514 - Fundamentals of Wind Energy has been established and offered and an interactive prediction of VAWT performance developed. Vertical axis wind turbines for education and research have been acquired, instrumented and installed on the roof top of a building on the Calumet campus and at West Lafayette (Kepner Lab). Computational Fluid Dynamics (CFD) calculations have been performed to simulate these urban wind environments. Also, modal dynamic testing of the West Lafayette VAWT has been performed and a novel horizontal axis design initiated. The 50-meter meteorological tower data obtained at the Purdue Beck Agricultural Research Center have been analyzed and the Purdue Reconfigurable Micro Wind Farm established and simulations directed at the investigation of wind farm configurations initiated. The virtual wind turbine and wind turbine farm simulation in the Visualization Lab has been initiated.

17 WIND ENERGY↗

Bill Savings vs. Backup Power: Evaluating operational tradeoffs for home solar+storage systems [Slides]

Adoption of residential solar photovoltaic+energy storage systems (PVESS) is driven by both bill savings opportunities and customer demand for backup power. Prior work by this team (Gorman et al., 2022; Gorman et al., 2023) explored PVESS backup power capabilities during long-duration power interruptions (e.g., due to severe weather events), when customers are assumed to be able to anticipate the event and charge their batteries in advance. In many cases, however, power interruptions are unpredictable (and often relatively short); for those types of events, a customer will typically set its battery to maintain some minimum capacity in reserve in case of an interruption, which reduces the capacity available for managing utility bills. This study evaluates this operational tradeoff to help customers and installers configure backup reserve settings, and to inform decision-making more generally about the customer value of backup power services compared to utility bill savings. This study utilizes Berkeley Lab’s PRESTO tool to produce stochastic simulations of (predominantly short-duration) power interruption events, and builds on an earlier case-study demonstrating PVESS backup performance during short-duration interruptions (Baik et al., 2023).

14 SOLAR ENERGY↗

Predicting Wind Loading and Instability in Solar Tracking PV Arrays

Wind loading and the fluctuating pressure loads it creates on PV panel surfaces are associated with multiple degradation mechanisms and failures. Modest wind speeds create reversing loads that can initiate cell cracks and weather cracked cells. Stronger wind speeds and extreme weather events can lead to larger scale forces and the aerodynamic instability known as torsional galloping. All these effects are dependent on the complex coupling between wind speed, panel orientation, and a myriad of other hardware and site-specific factors. In this work, we present the latest developments from our work to build an open-source, high-performance computing (HPC) fluid dynamics solver to predict and mitigate these effects. This simulation package allows users to easily specify different array layouts, solar-tracking angles, panel geometries, and weather conditions before automatically generating a refined computational mesh and solving for the unsteady loading on each panel surface. Small domains (e.g., a single panel row in isolation) can be solved on a modern laptop, while larger domains or very high-fidelity studies can be solved on distributed or HPC resources with minimal modifications to the underlying problem specification. We present preliminary case studies obtained using this simulation package and highlight how increased wind speeds combined with sub-optimal tracking angles can exacerbate degradation drivers.

aerodynamics↗

Investigation into the instantaneous centre of rotation for enhanced design of floating offshore wind turbines

The dynamic behaviour of floating offshore wind turbines (FOWTs) involves complex interactions of multivariate loads from wind, waves, and currents, which result in complex motion characteristics. Although methods for analysing global motion responses are well-established, the time- and location-dependent kinematics remain underexplored. This paper investigates the instantaneous centre of rotation (ICR), a point of zero velocity at a time instance of general plane motion. Understanding and strategically positioning the ICR can reduce the dynamic motion in critical structural locations, enhancing the performance and structural robustness of FOWTs. The paper presents a method for computing the ICR using time-domain simulation results and proposes a statistical analysis approach suitable for design studies. Building on prior research, it examines the sensitivity of the ICR to external loading and design features, providing insights into how these factors influence motion response and how the motion response influences the statistics of the ICR, structural loads, and other performance metrics of interest. The study explores two FOWT configurations, a spar and a semisubmersible, identifying design variables that most effectively control the ICR statistics and identifying the ICR statistics most correlated with the responses of interest. Finally, through two case studies, we demonstrate how to apply these new insights in a practical design scenario. By adjusting the design variables most correlated with the ICR (fairlead vertical position and centre of mass for the spar and mooring line length and offset column diameter for the semisubmersible), we successfully modified the designs of the floating support structures to reduce the loads in the mooring lines, tower base, and blade roots, improving the ultimate strength and fatigue characteristics compared to the original designs.

17 WIND ENERGY↗

Benchmarking the Performance of Neuromorphic and Spiking Neural Network Simulators

Software simulators play a critical role in the development of new algorithms and system architectures in any field of engineering. Neuromorphic computing, which has shown potential in building brain-inspired energy-efficient hardware, suffers a slow-down in the development cycle due to a lack of flexible and easy-to-use simulators of either neuromorphic hardware itself or of spiking neural networks (SNNs), the type of neural network computation executed on most neuromorphic systems. While there are several openly available neuromorphic or SNN simulation packages developed by a variety of research groups, they have mostly targeted computational neuroscience simulations, and only a few have targeted small-scale machine learning tasks with SNNs. Evaluations or comparisons of these simulators have often targeted computational neuroscience-style workloads. In this work, we seek to evaluate the performance of several publicly available SNN simulators with respect to non-computational neuroscience workloads, in terms of speed, flexibility, and scalability. We evaluate the performance of the NEST, Brian2, Brian2GeNN, BindsNET and Nengo packages under a common front-end neuromorphic framework. Our evaluation tasks include a variety of different network architectures and workload types to mimic the computation common in different algorithms, including feed-forward network inference, genetic algorithms, and reservoir computing. We also study the scalability of each of these simulators when running on different computing hardware, from single core CPU workstations to multi-node supercomputers. Our results show that the BindsNET simulator has the best speed and scalability for most of the SNN workloads (sparse, dense, and layered SNN architectures) on a single core CPU. However, when comparing the simulators leveraging the GPU capabilities, Brian2GeNN outperforms the others for these workloads in terms of scalability. NEST performs the best for small sparse networks and is also the most flexible simulator in terms of reconfiguration capability NEST shows a speedup of at least 2x compared to the other packages when running evolutionary algorithms for SNNs. The multi-node and multi-thread capabilities of NEST show at least 2x speedup compared to the rest of the simulators (single core CPU or GPU based simulators) for large and sparse networks. We conclude our work by providing a set of recommendations on the suitability of employing these simulators for different tasks and scales of operations. We also present the characteristics for a future generic ideal SNN simulator for different neuromorphic computing workloads.

97 MATHEMATICS AND COMPUTING↗

Validation of edge turbulence codes against the TCV-X21 diverted L-mode reference case

Self-consistent full-size turbulent-transport simulations of the divertor and scrape-off-layer (SOL) of existing tokamaks have recently become feasible. This enables the direct comparison of turbulence simulations against experimental measurements. In this work, we perform a series of diverted ohmic L-mode discharges on the tokamak à configuration variable (TCV) tokamak, building a first-of-a-kind dataset for the validation of edge turbulence models. This dataset, referred to as TCV-X21, contains measurements from five diagnostic systems from the outboard midplane (OMP) to the divertor targets—giving a total of 45 one- and two-dimensional comparison observables in two toroidal magnetic field directions. The experimental dataset is used to validate three flux-driven 3D fluid-turbulence models—GBS, GRILLIX and TOKAM3X. With each model, we perform simulations of the TCV-X21 scenario, individually tuning the particle and power source rates to achieve a reasonable match of the upstream separatrix value of density and electron temperature. We find that the simulations match the experimental profiles for most observables at the OMP—both in terms of profile shape and absolute magnitude—while a comparatively poorer agreement is found towards the divertor targets. The match between simulation and experiment is seen to be sensitive to the value of the resistivity, the heat conductivities, the power injection rate and the choice of sheath boundary conditions. Additionally, despite targeting a sheath-limited regime, the discrepancy between simulations and experiment also suggests that the neutral dynamics should be included. The results of this validation show that turbulence models are able to perform simulations of existing devices and achieve reasonable agreement with experimental measurements. Where disagreement is found, the validation helps to identify how the models can be improved. By publicly releasing the experimental dataset and validation analysis, this work should help to guide and accelerate the development of predictive turbulence simulations of the edge and SOL.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Hierarchical fuzzy control of low-energy building systems

A hierarchical fuzzy supervisory controller is described that is capable of optimizing the operation of a low-energy building, which uses solar energy to heat and cool its interior spaces. The highest level fuzzy rules choose the most appropriate set of lower level rules according to the weather and occupancy information; the second level fuzzy rules determine an optimal energy profile and the overall modes of operation of the heating, ventilating and air-conditioning system (HVAC); the third level fuzzy rules select the mode of operation of specific equipment, and assign schedules to the local controllers so that the optimal energy profile can be achieved in the most efficient way. Computer simulation is used to compare the hierarchical fuzzy control scheme with a supervisory control scheme based on expert rules. The performance is evaluated by comparing the energy consumption and thermal comfort. (author)

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Simplified Performance Rating Method - Review of Existing Tools, Rulesets, and Programs. Literature and technical review

The Performance Rating Method (PRM) in ASHRAE Standard 90.1 (ASHRAE 2016) is a simulation ruleset for establishing minimum code compliance and for rating a building’s beyond-code applications. Building energy modeling (BEM) to comply with the PRM is often expensive and time consuming due to the complexity of code requirements. The goal of this project is to develop and codify a simplified PRM (S-PRM) approach for commercial buildings that will expand the use of BEM for small or simple buildings by defining a low-cost, simplified approach for creating robust and detailed models. This report summarizes a review of (i) the more commonly used existing codes, (ii) incentive programs, and (iii) the existing simplified energy modeling tools to identify which requirements are good candidates for simplification.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Laboratory Testing of Demand-Response Enabled Household Appliances

With the advent of the Advanced Metering Infrastructure (AMI) systems capable of two-way communications between the utility's grid and the building, there has been significant effort in the Automated Home Energy Management (AHEM) industry to develop capabilities that allow residential building systems to respond to utility demand events by temporarily reducing their electricity usage. Major appliance manufacturers are following suit by developing Home Area Network (HAN)-tied appliance suites that can take signals from the home's 'smart meter,' a.k.a. AMI meter, and adjust their run cycles accordingly. There are numerous strategies that can be employed by household appliances to respond to demand-side management opportunities, and they could result in substantial reductions in electricity bills for the residents depending on the pricing structures used by the utilities to incent these types of responses. The first step to quantifying these end effects is to test these systems and their responses in simulated demand-response (DR) conditions while monitoring energy use and overall system performance.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Provenance In Sensor Data Management: A Cohesive, Independent Solution

In today's information-driven workplaces, data is constantly undergoing transformations and being moved around. The typical business-as-usual approach is to use email attachments, shared network locations, databases, and now, the cloud. More often than not, there are multiple versions of the data sitting in different locations and users of this data are confounded by the lack of metadata describing its provenance, or in other words, its lineage. Our project is aimed to solve this issue in the context of sensor data. The Oak Ridge National Laboratory's Building Technologies Research and Integration Center has reconfigurable commercial buildings deployed on the Flexible Research Platforms (FRPs). These FRPs are instrumented with a large number of sensors which measure a number of variables such as HVAC efficiency, relative humidity, and temperature gradients across doors, windows, and walls. Sub-minute resolution data from hundreds of channels is acquired. This sensor data, traditionally, was saved to a shared network location which was accessible to a number of scientists for performing complicated simulation and analysis tasks. The sensor data also participates in elaborate quality assurance exercises as a result of inherent faults. Sometimes, faults are induced to observe building behavior. It became apparent that proper scientific controls required not just managing the data acquisition and delivery, but to also manage the metadata associated with temporal subsets of the sensor data. We built a system named ProvDMS, or Provenance Data Management System for the FRPs, which would both allow researchers to retrieve data of interest as well as trace data lineage. This provides researchers a one-stop shop for comprehensive views of various data transformation allowing researchers to effectively trace their data to its source so that experiments, and derivations of experiments, may be reused and reproduced without much overhead of the repeatability of experiments that use it. Using these traces, researchers can determine exactly what happens to data as it moves through its life cycle.

Hensley, Zachary P↗

Laboratory Testing of Demand-Response Enabled Household Appliances

With the advent of the Advanced Metering Infrastructure (AMI) systems capable of two-way communications between the utility's grid and the building, there has been significant effort in the Automated Home Energy Management (AHEM) industry to develop capabilities that allow residential building systems to respond to utility demand events by temporarily reducing their electricity usage. Major appliance manufacturers are following suit by developing Home Area Network (HAN)-tied appliance suites that can take signals from the home's 'smart meter,' a.k.a. AMI meter, and adjust their run cycles accordingly. There are numerous strategies that can be employed by household appliances to respond to demand-side management opportunities, and they could result in substantial reductions in electricity bills for the residents depending on the pricing structures used by the utilities to incent these types of responses.The first step to quantifying these end effects is to test these systems and their responses in simulated demand-response (DR) conditions while monitoring energy use and overall system performance.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Status on the Development of a Modeling and Simulation Framework for the Economic Assessment of Nuclear Hybrid Energy Systems

An effort to design and build a modeling and simulation framework to assess the economic viability of Nuclear Hybrid Energy Systems (NHES) was undertaken in fiscal year 2015 (FY15). The purpose of this report is to document the various tasks associated with the development of such a framework and to provide a status on its progress. Several tasks have been accomplished. First, starting from a simulation strategy, a rigorous mathematical formulation has been achieved in which the economic optimization of a Nuclear Hybrid Energy System is presented as a constrained robust (under uncertainty) optimization problem. Some possible algorithms for the solution of the optimization problem are presented. A variation of the Simultaneous Perturbation Stochastic Approximation algorithm has been implemented in RAVEN and preliminary tests have been performed. The development of the software infrastructure to support the simulation of the whole NHES has also moved forward. The coupling between RAVEN and an implementation of the Modelica language (OpenModelica) has been implemented, migrated under several operating systems and tested using an adapted model of a desalination plant. In particular, this exercise was focused on testing the coupling of the different code systems; testing parallel, computationally expensive simulations on the INL cluster; and providing a proof of concept for the possibility of using surrogate models to represent the different NHES subsystems. Another important step was the porting of the RAVEN code under the Windows™ operating system. This accomplishment makes RAVEN compatible with the development environment that is being used for dynamic simulation of NHES components. A very simplified model of a NHES on the electric market has been built in RAVEN to confirm expectations on the analysis capability of RAVEN to provide insight into system economics and to test the capability of RAVEN to identify limit surfaces even for stochastic constraints. This capability will be needed in the future to enforce the stochastic constraints on the electric demand coverage from the NHES. The development team gained experience with many of the tools that are currently envisioned for use in the economic analysis of NHES and completed several important steps. Given the complexity of the project, preference has been given to a structural approach in which several independent efforts have been used to build the cornerstone of the simulation framework. While this is good approach in establishing such a complex framework, it may delay reaching more complete results on the performance of analyzed system configurations. The integration of the previously reported exergy analysis approach was initially proposed as part of this milestone. However, in reality, the exergy-based apportioning of cost will take place only in a second stage of the implementation since it will be used to properly allocate cost among the different NHES subsystems. Therefore, exergy does not appear at the level of the main drivers in the analysis framework; the latter development of the base framework is the focus of this report.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Advanced Energy Retrofit Guide Retail Buildings

The Advanced Energy Retrofit Guide for Retail Buildings is a component of the Department of Energy’s Advanced Energy Retrofit Guides for Existing Buildings series. The aim of the guides is to facilitate a rapid escalation in the number of energy efficiency projects in existing buildings and to enhance the quality and depth of those projects. By presenting general project planning guidance as well as financial payback metrics for the most common energy efficiency measures, these guides provide a practical roadmap to effectively planning and implementing performance improvements for existing buildings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

High‐Performance Low‐Emissivity Paints Enabled by N‐Doped Poly(benzodifurandione) (n‐PBDF) for Energy‐Efficient Buildings

Abstract Low‐emissivity (low‐e) paints reduce radiative heat exchange between buildings and the environment, stabilizing indoor climates and lowering air conditioning demand. However, low‐cost, durable, and colored low‐e paints have yet to be demonstrated. Here, an approach is proposed using n‐doped poly(benzodifurandione) (n‐PBDF), a transparent organic conducting polymer, coated over colored commercial paints. This achieves a low thermal emissivity of 0.19 in the mid‐infrared spectrum, attributed to the efficient charge transport of delocalized π‐electrons in n‐PBDF structure. The reduction in thermal emissivity aids in regulating building temperatures by minimizing heat transfer between buildings and their surroundings across diverse climate zones and seasons. The n‐PBDF coating preserves the underlying paint's color due to its high visible transparency, meeting aesthetic requirements. It also shows strong stability in accelerated indoor weathering tests, ensuring long‐term performance. Simulations estimate annual HVAC energy savings of over 10,800 kWh in San Francisco and 5,500 kWh in Chicago for the typical mid‐rise apartments. The paint's versatility, scalability, and durability make it suitable for buildings, vehicles, and greenhouses, aiding urban heat island mitigation.

Liu, Xiaojie [School of Mechanical Engineering and↗

Laboratory Performance Evaluation of Residential Integrated Heat Pump Water Heaters

This paper explores the laboratory performance of five integrated Heat Pump Water Heaters (HPWHs) across a wide range of operating conditions representative of U.S. climate regions. HPWHs are expected to provide significant energy savings in certain climate zones when compared to typical electric resistance water heaters. Results show that this technology is a viable option in most climates, but differences in control schemes and design features impact the performance of the units tested. Tests were conducted to map heat pump performance across the operating range and to determine the logic used to control the heat pump and the backup electric heaters. Other tests performed include two unique draw profile tests, reduced air flow performance tests and the standard DOE rating tests. The results from all these tests are presented here for all five units tested. The results of these tests will be used to improve the EnergyPlus heat pump water heater for use in BEopt™ whole-house building simulations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluating Domestic Hot Water Distribution System Options with Validated Analysis Models

A developing body of work is forming that collects data on domestic hot water consumption, water use behaviors, and energy efficiency of various distribution systems. Transient System Simulation Tool (TRNSYS) is a full distribution system developed that has been validated using field monitoring data and then exercised in a number of climates to understand climate impact on performance. In this study, the Building America team built upon previous analysis modeling work to evaluate differing distribution systems and the sensitivities of water heating energy and water use efficiency to variations of climate, load, distribution type, insulation and compact plumbing practices. Overall, 124 different TRNSYS models were simulated. The results of this work are useful in informing future development of water heating best practices guides as well as more accurate (and simulation time efficient) distribution models for annual whole house simulation programs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy and economic assessment of desiccant cooling systems coupled with single glazed air and hybrid PV/thermal solar collectors for applications in hot and humid climate

This paper presents a detailed analysis of the energy and economic performance of desiccant cooling systems (DEC) equipped with both single glazed standard air and hybrid photovoltaic/thermal (PV/t) collectors for applications in hot and humid climates. The use of 'solar cogeneration' by means of PV/t hybrid collectors enables the simultaneous production of electricity and heat, which can be directly used by desiccant air handling units, thereby making it possible to achieve very energy savings. The present work shows the results of detailed simulations conducted for a set of desiccant cooling systems operating without any heat storage. System performance was investigated through hourly simulations for different systems and load combinations. Three configurations of DEC systems were considered: standard DEC, DEC with an integrated heat pump and DEC with an enthalpy wheel. Two kinds of building occupations were considered: office and lecture room. Moreover, three configurations of solar-assisted air handling units (AHU) equipped with desiccant wheels were considered and compared with standard AHUs, focusing on achievable primary energy savings. The relationship between the solar collector's area and the specific primary energy consumption for different system configurations and building occupation patterns is described. For both occupation patterns, sensitivity analysis on system performance was performed for different solar collector areas. Also, this work presents an economic assessment of the systems. The cost of conserved energy and the payback time were calculated, with and without public incentives for solar cooling systems. It is worth noting that the use of photovoltaics, and thus the exploitation of related available incentives in many European countries, could positively influence the spread of solar air cooling technologies (SAC). An outcome of this work is that SAC systems equipped with PV/t collectors are shown to have better performance in terms of primary energy saving than conventional systems fed by vapour compression chillers and coupled with PV cells. All SAC systems present good figures for primary energy consumption. The best performances are seen in systems with integrated heat pumps and small solar collector areas. The economics of these SAC systems at current equipment costs and energy prices are acceptable. They become more interesting in the case of public incentives of up to 30% of the investment cost (Simple Payback Time from 5 to 10 years) and doubled energy prices. (author)

14 SOLAR ENERGY↗

Multi-fidelity physics-informed machine learning for probabilistic damage diagnosis

Machine learning (ML) models are gaining popularity in structural health monitoring (SHM) because of their ability to learn the complex relationship between damage and sensor data. However, the lack of sufficient experimental data for structures with different degrees of damage is a key problem in training ML models for SHM. This problem can be alleviated by using physics-based models to generate the required training data to build physics-informed ML (PIML) models for SHM. However, it takes significant computational effort to perform enough high-fidelity simulations of the diagnostic test. It is thus desirable to know whether the available computational resource budget should be expended on numerous low-fidelity physics simulations, or a small number of high-fidelity simulations, or their combination. In this paper, we investigate this aspect of generating adequate training data for PIML, by constructing multi-fidelity PIML models. We evaluate the performance of several PIML models, trained with different amounts of low-fidelity and high-fidelity data, in locating hidden cracks in concrete structures using a nonlinear dynamics-based diagnosis technique. Here, we find that high-fidelity physics simulations that do not cover the (test and damage) parameter space do not improve the performance of diagnostic PIML models built using data from many low-fidelity physics simulations.

42 ENGINEERING↗