Search NASA⌕ Search

SEARCH · Search NASA

Results for “CEBAF”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

A Magnetized Electron Source For Ion Beam Cooling

A number of electron-ion collider facilities for nuclear physics research are under consid- eration in the United States. At Brookhaven National Lab (BNL), the eRHIC (electron Relativistic Heavy Ion Collider) facility would augment the existing ion/proton facility with an electron accelerator. Thomas Jefferson National Accelerator Facility (JLab) plans to use the existing CEBAF machine and add an ion/proton accelerator, as part of the Jefferson Lab Electron-Ion Collider (JLEIC). All such facilities require cooling of the ion beams in order to reach the luminosity goals. Different methods of cooling the ions using an electron beam are envisaged. BNL is pursuing coherent electron cooling and non-magnetized, bunched-beam cooling, while JLab is considering magnetized cooling. In addition to electron cooling, magnetized beams are of interest for other applica- tions, such as flat beam klystrons and novel means for producing bright beams for micro- undulators and compact X-ray sources. For example, flat beams generated from a mag- netized injector, in conjunction with low emittance, enable RF sources with frequencies above 100 GHz. While the market for high-performance injectors for electron cooling is limited, the market for high-frequency RF sources and compact X-ray systems is con- siderable. Thus, the design methodologies developed in this project have a wide range of applicability. In Phase I of this SBIR project, Xelera Research LLC performed simulations and calcu- lations to develop a prototype design for a magnetized electron injector that can be used as a source for cooling an ion beam. We developed general design methodologies and tech- niques that are applicable not only to specific machine designs but to other applications requiring magnetized injectors as well. In this Phase II SBIR project, Xelera Research LLC, in collaboration with a team at JLab, designed, built, and tested a thermionic elec- tron source for driving a magnetized electron cooler in a future electron-ion collider project. This device was delivered to JLab in July 2019 and achieved first beam in December 2019.

43 PARTICLE ACCELERATORS↗

Exotic Meson Photoproduction at GlueX – Search for the hybrid candidate Y

Understanding the hadron spectrum is one of the primary goals of non-perturbative QCD. Many predictions have experimentally been confirmed, others still remain under experimental investigation. Of particular interest is how gluonic excitations give rise to states with constituent glue. One class of such states are hybrid mesons that are predicted by theoretical models and Lattice QCD calculations. Searching for and understanding the nature of these states is a primary physics goal of the GlueX experiment at the CEBAF accelerator at Jefferson Lab. A search for a JPC = 1-- hybrid meson candidate, the Y (2175), in phi(1020)pi+pi+ and phi(1020)f0(980) channels in photoproduction on a proton target has been conducted. A first measurement of non-resonant phi(1020)pi+pi+ and phi(1020)f0(980) total cross sections in photoproduction has been performed. An upper limit on the resonance production cross section for the Y (2175) -> phi(1020)pi+pi+ and Y (2175) -> phi(1020)f0(980) channels are estimated. Since the analysis essentially depends on the quality of the charged kaon identification, also an optimization of particle identification through an improvement of the energy loss estimation in the CDC by a truncated mean method has been investigated.

Hamdi, Abdennacer↗

Photo-Production of eta Mesons

In this work we present the GlueX experiment extensive high statistics measurements of the eta meson photo-production differential cross sections at beam energies between 3 GeV and 11.6 GeV. We compared the low energy (2.9 GeV< Ey < 5.9 GeV) differential cross section (d-sigma/d-Omega) results to previous experimental results from the Continuous Electron Beam Accelerator Facility (CEBAF) Large Acceptance Spectrometer (CLAS) collaboration. These (d-sigma/d-Omega) results are also compared to the theoretical isobar model EtaMAID2018 by Tiator et. al., and the Regge model by Nys et. al. The differential cross section d-sigma/dt is also presented and compared to the previous experimental results, and to the above models, in addition to a model by J. M. Laget. The high energy (6.2 GeV< Ey < 11.6 GeV) cross section results (d-sigma/d-Omega, and d-sigma/dt) are compared to the isobar model EtaMAID2018. These results will provide new constraints on eta photo-production mechanisms and high energy t-channel processes.

Kamel, Mahmoud↗

Isotope Production at the Jefferson Lab LERF Facility (Final Report)

The project initially proceeded well, meeting all of the Milestones. However, the need to create a new irradiation area in the LERF (the initial proposal was to use the CEBAF Injector) used up a larger fraction of the budget than foreseen. A further problem arose when the hot-cell became unavailable at VCU, followed by VCU dropping out of the collaboration. This meant that we were unable to separate the 67 Cu from the gallium. We replaced this by carrying out detailed gamma spectroscopy to determine the quantity of 67 Cu produced.

07 ISOTOPE AND RADIATION SOURCES↗

INITIAL STUDIES OF CAVITY FAULT PREDICTION AT JEFFERSON LABORATORY

The Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Laboratory is a CW recirculating linac that utilizes over 400 superconducting radio-frequency (SRF) cavities to accelerate electrons up to 12 GeV through 5-passes. Recent work has shown that, given RF signals from a cavity during a fault as input, machine learning approaches can accurately classify the fault type. In this paper we report on initial results of predicting a fault onset using only data prior to the failure event. A data set was constructed using time-series data immediately before a fault (’unstable’) and 1.5 seconds prior to a fault (’stable’) gathered from over 5,000 saved fault events. The data was used to train a binary classifier. The results gave key insights into the behavior of several fault types and provided motivation to investigate whether data prior to a failure event could also predict the type of fault. We discuss our method using a sliding window approach and report on initial results. Recent modifications to the low-level RF control system will provide access to streaming signals and we outline a path forward for leveraging deep learning on streaming data

Vidyaratne, Lasitha↗

Electron-Ion Collider - Plans for Realization

Understanding the emergence of nucleons and nuclei and their interactions from the properties and dynamics of quarks and gluons in Quantum Chromo-Dynamics (QCD) is a fundamental and compelling goal of nuclear science. An Electron-Ion Collider (EIC) was designated in the 2007 Nuclear Physics Long Range Plan as "embodying the vision for reaching the next QCD frontier," extending the QCD science programs in the U.S. established at both the CEBAF accelerator at JLab and RHIC at BNL in dramatic and fundamentally important ways. The 2013 Report of the NSAC Subcommittee on Major Nuclear Physics Facilities for the Next Decade reaffirmed an EIC as "absolutely central in its ability to contribute to world-leading science in the next decade." Two proposals for the EIC are being considered in the U.S.: one each at BNL and at Jefferson Laboratory. In this presentation we will review these proposals of the EIC, their implementation plan, and comment on the physics opportunities they present to the nuclear science communities in the next decade

Rossi, Patrizia↗

Nucleon structure studies via deeply virtual exclusive reactions at Jlab

Deeply virtual exclusive reactions, and in particular deeply virtual Compton scattering (DVCS), are expected to give access to the generalized parton distributions (GPDs) in the nucleon. After summarizing the connection between DVCS and GPDs, the impact of recent results from dedicated DVCS experiments at Jefferson Lab will be discussed. Preliminary results on vector meson exclusive production will be shown as well. In 2007-2009, DVCS experiments will be performed at CLAS using unpolarized and polarized targets (both longitudinally and transversely polarized). The latter will yield observables sensitive the GPDs H_tilde and E. In conjunction with the 12 GeV upgrade of the CEBAF accelerator, large scale DVCS experiments have been already approved, both in CLAS12 (which will be described in some details) and in Hall A.

Garcon, Michel↗

SRF Cavity Fault Classification and Prediction at Jefferson Lab

Over the last few years several machine learning projects at Jefferson Lab have had a common focus to optimize operation of superconducting RF (SRF) cavities in the Continuous Electron Beam Accelerator Facility (CEBAF). In this talk we highlight work to identify and classify types of faults from C100-type cavities and then to extend those capabilities to provide real-time fault prediction. Early prediction may enable mitigation strategies to prevent some types of faults. In our approach we apply a two-step fault prediction pipeline. In the first step, a model distinguishes between faulty and normal signals. In the second step, signals flagged as faulty by the first model are classified into one of seven fault types based on learned signatures in the data. Initial results show that our model can successfully predict most fault types 200 ms before onset. In additional to model performance, we also highlight challenges in working with real-world data and challenges for deploying models.

Tennant, C.↗

Present and future of JLab CLAS12 physics program

The CLAS12 detector at Jefferson Lab produced the first results in SIDIS and DI-HADRON reactions. Making use of the CEBAF high energy (up to 11 GeV) and highly longitudinal polartized (up to 90%) electron beam will cover unexplored territories in electron-scattering physics. Exclusive reactions on nuclons and nuclei will be measured with high precision in high luminosity (up to 10e35 cm-2s-1) experiments. Mapping out a new class of structure functions, GPDs and TMDs, detecting and reconstructing exotic meson and baryon states and accessing nucleons correlations in nuclei, in the next decade, the CLAS12 rich physics program will provide insight in the complex dynamics of the QCD paving the road to the EIC physics. In this talk, the CLAS12 detector and JLab Hall-B physics program will be described reporting some preliminary results for flag-ship reactions and plans for future upgrades of the detector.

Battaglieri, Marco↗

Development of High-efficiency and Cost-effective Forged Ingot Niobium Technology for Science Frontiers and Accelerator Applications

Development of Forged Ingot Niobium Technology: Worlds science frontier programs and SRF accelerator applications demand high performance and cost-effective SRF accelerator technology [1-8]. Fine-grain (FG) and Large-grain (LG) ingot niobium technologies have been very well developed and implemented in all the present-day accelerator projects. However, forged ingot niobium technology which is the focus of this development proposal will be much more cost-effective and expected to have several technical advantages. FG niobium sheet production is very complex involving more than ten processing steps making them prone to contamination. As a result, they are very expensive to produce and require stringent QA procedure to be ready for SRF cavity production. The accelerating cavity process steps are also numerous and require strict procedures in order to achieve high accelerating gradients and quality factors needed for science frontier programs. LG niobium disc production, directly sliced from the ingot, is relatively simple and straight forward to keep surface cleanness. The disc production cost is significantly low compared to FG niobium sheet production. However, there are (some) draw backs due to non-homogeneity of the grain boundary distribution, resulting in non-uniform mechanical properties and complex cavity fabrication, although the LG cavities achieve the expected high-gradient performance goals with lower cost. Medium-grain (MG) niobium disk production may be realized with a new approach/process, the disc directly sliced from the forged ingot, involves a simpler process steps contributing major production cost reduction [9]. These discs are expected to be superior as they tend to be homogenous with uniform sub millimeter grains and mechanical properties. We are eagerly looking forward to developing the forged ingot niobium SRF accelerator technology for the benefit of the world-wide science frontier programs, green energy subcritical nuclear energy systems and a wide variety of industrial applications including the production of radio isotopes and nuclear transmutation applications. Measurement of thermal characteristics of the forged ingot niobium: Measurement of the thermal diffusivity, D, of superconducting MG niobium is important to be understood in comparison with FG sheet and LG disc, as well as that of advanced composite material of Nb3Sn film sputtered on forged ingot Nb, which will be determined using transient pump-probe thermo-modulation [10,11]. Transient thermo-modulation is based on using an ultrafast laser pulse to heat the superconducting materials by a few K, then a synchronized laser pulse probes the reflectance of the heated material. For thin films on a substrate (e.g, 100-nm Nb3Sn on Nb), it takes <100 ps for the heat to reach the substrate by diffusion. Therefore, an ultrafast method is needed to probe D of the studied material. D will be measured from room temperature to liquid helium temperatures. Fundamental Research: The increase of rf loss in SRF cavities is related to trapping of residual magnetic field during the cavity cool-down. The study suggested that the micro structure plays the role in flux trapping sensitivity. The research includes the flux trapping and expulsion study as forged ingot niobium goes through several mechanical deformations, crystallization leading to the optimal SRF cavity performance. Furthermore, the cavity made from FG, MG, and LG sheet/disc will be compared to understand the optimal re-crystallization temperature that cavity needed to be heat treated which minimize the flux trapping and increase SRF cavity performance. References: 1. S. Belomestnykh, Overview of recent SRF developments for ERLs, presented at the SRF 2015, Whistler, BC, Canada (2015). 2. A. Yamamoto, M. Yamanaka and G. Myneni, Ingot Nb based SRF Technology for the International Linear Collider, in Science and Technology of Ingot Niobium for Superconducting Radio Frequency Applications, AIP Conf. Proc. 1687, 030005-1 ? 03005-6, 2015 3. Report of the Workshop on Energy and Environmental Applications of Accelerators, DOE Workshop Report. https://science.osti.gov/-/media/hep/pdf/Reports/2020/CASM_WorkshopReport.pdf? la=en&hash=AEB0B318ED0436B1C5FF4EE0FDD6DEB84C2F15B2 4. G. Ciovati, et al., Design of a cw, low-energy, high-power superconducting linac for environmental applications, Phys. Rev. Accel. Beams 21, 091601 (2018). 5. P. Dhakal, et al., Effect of high temperature heat treatments on the quality factor of a large-grain superconducting radio-frequency niobium cavity, Phys. Rev. ST Accel. Beams 16, 042001 (2013). 6. P. Kneisel et al., Review of ingot niobium as a material for superconducting radio frequency accelerating cavities, Nuclear Instruments and Methods in Physics Research A 774, 133 (2015). 7. G. Ciovati, P. Dhakal, and G. R, Myneni, Superconducting radio-frequency cavities made from medium and low-purity niobium ingots, Supercond. Sci. Technol. 29, 064002 (2016). 8. M. Drury et al., commissioning of the prototype C75 cavities in a CEBAF cryomodule, in Proc. of IPAC 2018, Vancouver, BC, Canada (2018) 9. Feasibility of forged-ingot niobium disc and SRF cavity fabrication technology recently demonstrated in cooperation of ATI, BSCE, and KEK (2020). 10. Hani E. Elsayed-Ali, ?Measurements of heat transport in thin films by ultrafast laser-based techniques,? 3rd International Conference on Thermal Issues in Emerging Technologies Theory and Applications, Cairo, Egypt, pp. 347 ? 350 (2010). DOI: 10.1109/ThETA17616.2010 11. W. M. G. Ibrahim, H. E. Elsayed-Ali, M. Schinn, and C. A. Bonner, Jr., ?Ultrafast investigation of electron dynamics in multilayer metals,? Int. J. Heat and Mass Transfer, 47(10?11), 2261?2268 (2004).

Myneni, G.↗

Interaction Region Magnets for Future Electron-Ion Collider at Jefferson Lab

The Jefferson Lab Electron Ion Collider (JLEIC) is a pro-posed new machine for nuclear physics research. It uses the existing CEBAF accelerator as a full energy injector to deliver 3 to 12 GeV electrons into a new electron collider ring. An all new ion accelerator and collider complex will deliver up to 200 GeV protons. The machine has luminosity goals of 1034 cm-2 sec-1. The whole detector region including forward detection covers about 80 meters of the JLEIC complex. The interaction region design has recently been optimized to accommodate 200 GeV proton energy using conventional NbTi superconducting magnet technology. This paper will describe the requirements and preliminary designs for both the ion and electron beam magnets in the most complex 34.5 m long interaction region (IR) around the interaction point (IP). The interaction region has over thirty-four superconducting magnets operating at 4.5K; these include dipoles, quadrupoles, skew quadrupoles, solenoids, horizontal and vertical correctors and higher order multipole magnets. The paper will also dis-cuss the electromagnetic interaction between these magnets.

Rajput-Ghoshal, Renuka↗

Evaluation of a streaming readout solution for Jefferson Lab experiments

Jefferson Lab (JLab) operates the CEBAF accelerator that provides a high energy (up to 12 GeV) and high current (up to 150 µA) polarized electron beam for fixed target experiments. JLab's mission is to provide substantial progress in understanding the Quantum Chromo Dynamics (QCD), the current theory of the spectrum and the dynamics of hadronic matter. Given the broad scientific program a general-purpose detector, CLAS12, has been designed and constructed. Such a detector requires a sophisticated trigger and current experiments use an on-line FPGA-based system that relies upon custom firmware and electronics both of which are difficult reconfigure from one experiment to the next. To overcome these challenges transitioning to a streaming readout has been proposed since it would allow a more flexible, easier to debug, software trigger to be developed. To facilitate this JLab is gaining experience with streaming readout systems and is actively working to design and test a streaming data acquisition architecture. Significant work has already been done to make existing front-end electronics compatible with operation in streaming mode. Software-wise, much work remains to be done but an existing framework, TriDAS, which was developed for underwater neutrino telescopes can, in principle, be used with the existing JLab hardware. A test stand is already in place in the INDRA DAQ development lab at JLab. This paper will present the development of this TriDAS based test system and it?s operation in-beam using parts of the CLAS12 detector to evaluate streaming readout for a large general purpose detector.

Battaglieri, Marco↗

Optimization of an Interaction Region Quadrupole Magnet for a Future Electron-Ion Collider at JLab

The Jefferson Lab Electron Ion Collider (JLEIC) is a proposed new machine for nuclear physics research. It uses the existing CEBAF accelerator as a full energy injector to deliver 3 to 11 GeV electrons into a new electron collider ring. An all new ion accelerator and collider complex will deliver up to 200 GeV protons. The machine has luminosity goals of 10 34 cm -2 sec -1 . The whole detector region including forward detection covers about 80 meters of the JLEIC complex. The lattice file for the machine has changed to accommodate the higher energy; this change requires all the magnets in the interaction region to change. This paper will describe the requirements for both the ion and electron beam superconducting magnets around the interaction point. All the Final Focusing Quadrupole (FFQ) magnets now have preliminary designs. This paper will describe the optimization process for one of these FFQs. The optimization is performed using the optimization module of SIMULIA Opera FEA and compared with ROXIE. An analytical design tool has also been developed to estimate the peak field in the coils. The quadrupole has been optimized for peak field in the coils, and magnetic length.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Polarized Positron in Jefferson Lab Electron Ion Collider (JLEIC)

The Jefferson Lab Electron Ion Collider (JLEIC) is a proposed new nuclear physics facility designed to deliver high luminosity and high polarization electron-ion collisions. JLEIC employs high repetition rate collisions of short low emittance bunches to achieve the electron ion luminosity goal of 10^{33}-10^{34}cm^{-2}s^{-1} over a wide range of center-of-mass energy. With a growing physics interest, a positron-ion collision scheme is under study for JLEIC. The JLEIC positron-ion scheme will use CEBAF as the positron injector with minimal modification, so the Polarized Electrons for Polarized Positrons (PEPPo) based positron generation scheme is chosen. The major challenge of this scheme is to generate the polarized positron bunch trains with the time structure and peak beam current required for the injection/top-off of the electron collider ring. In this talk, we will address the details of this scheme, with the focus on the positron beam formation, as well as the preliminary collider parameters optimized for positron-ion luminosity.

Guo, Jiquan↗

New Measurements of the EMC Effect in Hall-C

The x dependence of the EMC effect has been measured for a variety of nuclei in a multitude of experiments conducted over the past 35 years. Previous EMC ratio measurements for light nuclei (A?12) have shown a dependence on the local nuclear structure of nucleons and the associated modification to nuclear structure functions. The newly commissioned Super High Momentum Spectrometer (SHMS) in Hall-C has been used to collect inclusive electron scattering measurements on various light nuclei utilizing the 12 GeV CEBAF facility at Jefferson Lab. These data obtained during a portion of E12-10-008 includes previously unmeasured nuclei, namely 10B and 11B, and will therefore provide a comparison of nuclei which differ by just one nucleon. This will facilitate the extraction of the nucleon structure function as modified by the nuclear medium. Status of the target-ratio analysis of recently acquired E12-10-008 data will be discussed.

Pooser, Eric↗

Physics reach at JLab with the 12 GeV upgrade

The Continuous Electron Beam Accelerator Facility (CEBAF) and associated experimental equipment at Jefferson Lab comprise a unique facility for nuclear physics research whose upgrade has been just completed. The upgraded facility accelerates electron beams to 11 GeV for experiments in the existing Halls A, B and C. In addition, a 12 GeV beam is provided to a new experimental Hall D to generate a 9 GeV tagged photon beam. This upgrade will quantitatively address the nature of confinement and an era of nuclear femtography through precision measurements of the spectrum and structure of hadrons comprised of light quarks and gluons. This facility also provides new opportunities relevant to neutrino oscillation physics, ``dark photon'' searches, and precision tests of the standard model.

Rossi, Patrizia↗

Review of requirements and challenges

The development of an electron ion collider (EIC) as the next frontier in nuclear physics has been proposed by the National Academy of Sciences. A collider capable of meeting unprecedented energy and luminosity requirements imposes formidable technical challenges in many accelerator physics disciplines. Two EIC concepts have been proposed, one by Jefferson Lab based on a ring-ring collider design with strong ion cooling based on a magnetized beam. The high-energy polarized electron beam would be generated by the present 12 GeV CEBAF accelerator. The other concept proposed by Brookhaven National Laboratory is based on utilizing the existing RHIC ring and a polarized electron beam injected into an additional storage ring. Multiple cooler schemes are being explored for future luminosity upgrades. This talk summarizes the requirements and challenges on the electron source for the various cooler concepts being proposed.

Hernandez-Garcia, Carlos↗

Nb3Sn SRF Cavities for Nuclear Physics Applications

Nuclear physics experiments rely increasingly on accelerators, which employ superconducting RF (SRF) technology. CEBAF, SNS, FRIB, ESS, among others exploit the low surface resistance of SRF cavities to efficiently accelerate particle beams towards experimental targets. Niobium is the cavity material of choice for all current or planned SRF accelerators, but it has been long recognized that other superconductors with high superconducting transition temperatures have the potential to surpass niobium for SRF applications. Among the alternatives, Nb3Sn coated cavities are the most advanced on the path to practical applications: Nb3Sn coatings on R&D cavities have Tc consistently close the optimal 18 K, very low RF surface resistances, and very recently were shown to reach above Hc1 without anomalous RF surface resistance increase. In my talk I will discuss the prospects of Nb3Sn SRF cavities and the research efforts to realize Nb3Sn coatings on practical multi-cell accelerating structures.

Eremeev, Grigory↗