Search NASA⌕ Search

SEARCH · Search NASA

Results for “CONGESTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Effects of the State of Network on PTP accuracy – An ESnet Case Study

This report presents some of the effects and observations of the "state of network" on Precision Time Protocol (PTP) accuracy. "State of network" here refers to things like traffic on the network, network congestion, network routes, differences in paths taken in communication between two entities, etc. The network under consideration is ESnet.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Proxy Applications for Converged Workloads: DMC LDRD Initiative

Modern scientific applications are complicated and require coordination of several components. Proxy application driven software-hardware co-design plays a vital role in driving innovation among the developments of applications, software infrastructure and hardware architecture. Proxy applications are self-contained and simplified codes that are intended to model the performance-critical computations within applications. Applications executing on modern High Performance Computing (HPC) systems are susceptible to network congestion, insufficient memory bandwidth within and across compute nodes, and inadvertent loss of performance due to bugs and unoptimized programming models. Modern numerical simulations and machine learning models play a critical role in studying physical phenomenon under myriad uncertainties. Such applications often exhibit irregular computation and memory accesses at specific regions of the application code, which can contribute to various performance bottlenecks at scale. To mitigate such issues and prepare the next generation hardware for a variety of computation and data movement contingencies, a well-known practice is to consider "proxy" applications as representative motifs for various classes of scientific applications. While there is disagreement in the HPC community on the mechanisms of construction of the proxy applications, there is a strong consensus on their positive impact in co-design. Proxy Applications for Converged Workloads (PACER) is about facilitating software-hardware co-design through proxy applications with the goal of improving the performance of converged science workflows on heterogeneous systems.

97 MATHEMATICS AND COMPUTING↗

New Two-Cylinder Prototype Demonstration and Concept Design of a Next Generation Class 3-6 Opposed Piston Engine (Final Report)

The objective of the project is to research, develop, and test an Opposed Piston (OP) engine prototype capable of ≥10% fuel economy improvement over a 2015 baseline diesel engine while meeting prevailing emissions standards and include a cost analysis of the proposed technologies that validates an operating cost payback of less than 2 years. Results: In direct comparison with the baseline Isuzu model, the OP engine exhibited a noteworthy average fuel economy improvement exceeding 12% across five distinct driving cycles, including the Interstate cycle, Congested interstate cycle, GM-city cycle, HWFET cycle, and FTP cycle, with Interstate cycle benefited the most.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Options for Meeting Data Center Demand in Virginia: Focus on GETs and Reconductoring [Slides]

Data center demand growth in Virginia will need to met with many options - GETs and/or reconductoring have the potential to be part of the solution suite in the short-term and medium-term. Almost all GETs and reconductoring technologies have more favorable economics than transmission wires investments considering relatively low levels of existing wide-scale deployment. Deployment of GETs and/or reconductoring is not a one size fits all - requires detailed analysis. The complementary nature of GETs and/or reconductoring impacts have the potential to be synergistic (more congestion relief, more transfer capability, more cost savings - when implemented together).

24 POWER TRANSMISSION AND DISTRIBUTION↗

Integrating the Mobility Energy Productivity Metric into the CDOT Statewide Model

The Mobility Energy Productivity (MEP) metric measures the quality of mobility at a specific location and can be used to evaluate how changes to transportation systems impact the mobility of that location over time, such as through infrastructure investments. The objective of this study is to demonstrate integration of the MEP metric into CDOT's transportation planning process by leveraging data from their statewide travel demand model. We evaluate the MEP metric in 2015 as well as 2030 baselines and projected impacts in 2030 for two different regions in Colorado under multiple scenarios across multiple modes (driving, walking, biking, and transit). It was found that increasing development (increasing population density, jobs, and opportunities) had a significant impact on MEP, independent of any specific alternatives. For drive mode, there was a trade- off of increasing congestion on the road network and increasing job and opportunity access. Impacts to bike, walk, and transit MEP were also demonstrated in both regions. This report shows how MEP can be used as a tool to support evaluating the impacts of various transportation projects across the state. With projections of significant growth across the state of Colorado, access to the increasing opportunities and jobs will be important to understand through the context of energy efficiency. MEP could support future project evaluation and decision-making by enabling the unique and important dimension of energy- efficient accessibility of a transportation system.

33 ADVANCED PROPULSION SYSTEMS↗

A Review of Value of Solar Studies In Theory and In Practice

This brief summarizes a collection of state- and utility-commissioned value-of-solar (VoS) studies and related literature, with a focus on who commissioned the study, which value and cost categories were discussed and/or quantified, and the methods used. Our objective is to compile information on prior VoS studies to inform state regulators and other stakeholders that may pursue related studies or integrate findings into rate design. The brief is organized into three parts: 1) an introduction to distributed solar photovoltaic (DPV) compensation; 2) a review of theoretical research on VoS; and 3) a review of VoS studies. The vast majority of VoS studies have served an informational role of quantifying the net benefits of PV. Three studies were commissioned in states or utility service territories that subsequently implemented VoS tariffs in California, New York, and Austin, Texas. When applied as a tariff, VoS aims to compensate PV output as efficiently as possible by doing so at rates that reflect the marginal benefits and costs of PV through value and cost categories that may vary temporally and/or geographically. This could lead to higher compensation in locations and times where more PV output is more valuable and consequently drive adoption in those locations to provide more societal benefits. Value and cost factors can be broadly grouped into five categories: generation, transmission, distribution, other utility, and other social categories. Those conducting VoS studies must weigh various tradeoffs when deciding which categories to include and quantify. Tradeoffs include prioritizing values based on their magnitude of value or cost impact, as well as taking into account the feasibility of data collection and accurate quantification. Values of higher magnitude and estimation feasibility are quantified in the majority of studies, including the earliest of studies conducted in the 2000s and 2010s. Additionally, some values of higher magnitude but low feasibility in the earliest of studies have become quantifiable in recent years. There are some values with low average system-wide levels but very high magnitude in specific locations or hours. The value magnitude in some cases can be tied to DPV penetration with low value in areas with little congestion and/or low penetration and vice versa. In these cases, values that are easier to quantify are often incorporated, while those that are more difficult are often addressed via a placeholder value. The placeholder value is paired with a discussion around data needs and methods to improve future estimates, as well as a conversation about when these value categories may increase in magnitude and necessitate more rigorous quantification. This brief summarizes findings from two meta-analyses of VoS studies that took place between 2005 and 2018, as well as findings from four additional studies published from 2018 to 2023. Table ES-1 summarizes the various value and cost categories included in each respective study and whether they were quantified, discussed, or omitted. Values such as avoided energy, capacity, transmission capacity, line losses, and avoided environmental costs are quantified in every study. Some categories were deemed harder to quantify and less impactful at the time of the study, so they were discussed but not quantified (e.g., ancillary services). Other categories, including many at the distribution level, were very locationally and/or temporally specific and dependent on high DPV penetration. These were sometimes quantified and at other times discussed. Notably, when it came to utility costs, integration costs were discussed in all cases, though they were deemed to have a small impact. Other utility costs were omitted for the most part; however, the utility-commissioned study (by NorthWestern Energy in Montana) included both lost utility revenue and programmatic/administrative cost categories. While there are some similarities across studies, each had fairly unique methods that are detailed in the body of this brief.

14 SOLAR ENERGY↗

Unraveling the Noise: An Investigation Plan for Signal Interference in Hearing Aids

Bluetooth Low Energy (BLE) has revolutionized the performance of hearing aids with functionalities like seamless audio streaming and enhanced auditory functions. However, BLE operates within the highly congested 2.4 GHz frequency band, making it susceptible to signal interference that can degrade performance, reduce audio quality, and impact user experience. This paper documents interference patterns in BLE communication and introduces practical mitigation techniques aimed at improving the reliability of hearing aids. Attack vectors associated with Bluetooth enabled hearing aids include communication jamming, the interception of data between target devices, and GATT handle exploitation. Attackers could also use the vulnerabilities to block communications or intercept sensitive audio streams, posing significant security and privacy risks. These threats compromise two critical components of the CIA triad: (1) availability, by causing persistent connectivity issues, and (2) integrity, by enabling unauthorized data modifications. It is necessary to deal with these problems to ensure hearing aids work well and safely. This study investigates the impact of BLE signal interference on hearing aids, using tools such as HackRF [1], a Python tool to simulate interference scenarios, and Ubertooth [2] to sniff Bluetooth traffic between hearing aids and the device with the application. This paper investigates testing of BLE traffic in search of specific interference patterns that would impact the functionality of hearing aids, including jamming and flooding. This research focuses on developing robust mitigation techniques with the aim of securing BLE-enabled hearing aids against those vulnerabilities.

Baldwin, David [Savannah River National Laboratory↗

Investigation into the Performance Benefits of Exposing Network Backpressure in UPC++ and GASNet-EX

This document is a brief summary of the research, and supporting development efforts, conducted by the project "Investigation into Improving Dynamic Adaptivity to System-Level Asynchrony in UPC++". We tested the hypothesis "The UPC++ and GASNet-EX runtimes can expose information from the network stack that enables applications to dynamically adapt to congestion, improving total throughput". We present experimental results from both a microbenchmark and an application benchmark that support this hypothesis.

97 MATHEMATICS AND COMPUTING↗

Empirical Indicators of Transmission Value in the Southeast United States

Concurrent differences in energy price between different parts of the electric grid are a key indicator of the value of additional transmission. In areas without a wholesale electricity market, such as the Southeast, an alternative indicator to price is the Federal Energy Regulatory Commission’s (FERC) system lambda data. This economic metric represents the minimized marginal production costs of thermal generators, including fuel and other variable operation and maintenance expenses. Balancing Authorities report a single system lambda for their entire balancing area. Most Southeastern lambdas exhibit sufficient price variation to support a transmission valuation analysis, although incomplete accounting of congestion costs or scarcity rents during peak load hours may underestimate the true value of transmission capacity. With transmission value defined as the annual average hourly absolute price difference between two regions and FERC’s system lambda data used as a price proxy, we find the following results in the Southeast region during 2012-2023 (reported in $\$2024$/MWh): Intra‐regional findings: Annual averages historically span $\$2$–$\$28$/MWh and average $\$12$/MWh in SERTP and span $\$4$–$\$19$/MWh and average $\$9$/MWh in FRCC, disregarding transmission value driven by anomalous data. The ranges of transmission value reported here are large, spanning an order of magnitude in some cases. Much of this variation is driven by year-to-year changes, with 2022 having a particularly high intra-regional transmission value due to elevated natural gas prices. Inter‐regional corridors: Annual average transmission values across three broader regions range from $\$6$ to $\$28$/MWh with a long-term average of $\$11$/MWh. Much of the transmission value is concentrated in a small portion of hours. Across all regions, severe weather—particularly polar vortex events in January 2018, February 2021, and December 2022—drives the largest price spreads. Seasonal patterns also emerge, with summer afternoons and fall mornings contributing consistently to transmission value, as for example between MISO and SOCO in 2023.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Analyzing Trip Chaining Behavior in New York State Using 2009 and 2017 National Household Travel Survey

Trip chaining, defined as the sequential linking of trips by individuals throughout a given day, provides critical insights into daily mobility patterns and activity sequencing. Understanding these patterns has significant implications for transportation demand forecasting, congestion management, and local economic activity. This analysis examines trip chaining behaviors in New York State (NYS) for the years 2009 and 2017 and compares the Middle Atlantic Census Division with other U.S. regions in 2022, utilizing data from the National Household Travel Survey (NHTS). Through demographic, geographic, and temporal analysis, this study characterizes how populations organize travel for work, personal errands, and social activities, providing empirical evidence of evolving trip chaining behaviors to inform transportation planning strategies.

99 GENERAL AND MISCELLANEOUS↗

Surveillance & Detection (CRADA 567 Final Report)

This Cooperative Research and Development Agreement (CRADA) Final Report covers the work achieved by PNNL and it's commercial partner (Consolidated Resource Imaging, LLC) on video analytics for the DHS S&T Surveillance & Detection project. This project has been focused on development of the next-generation camera system (Guardian iiS) with extremely high resolution and video analytics specifically designed for crowded urban environments and congested transportation hubs.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

New Mobility Technology Assessment - Benefits, Risks, and Safety

The age of vehicle automation is upon us. The fundamental perception and control technology is maturing as we speak (and write) with robo-taxis proliferating in select US cities. The news cycle is no longer filled with technological skepticism, but rather societal commentary on our collective response and use of the technology. This maturing of the technology is also accompanied by a renaissance in new types of urban movement technology to more effectively link people with goods, services, and employment, particularly in dense development areas where vehicle congestion (even automated vehicles) prevents high quality mobility. The National Renewable Energy Laboratory, through the DOE Clean Energy to Communities (C2C) program has worked with two jurisdictions to assess the benefits, risks, and safety concerns for a new product offering based on suspended cable technology which is fully automated and proposes an aerial network of self-propelled gondolas. The recognized need, independent of the technology, is to fairly assess the benefits of the proposed transportation system, assess its technical maturity, as well as risks and safety concerns. Using this new technology as an example, a technology represented by Swyft Cities, NREL developed a succession of mini-studies that characterized the technical maturity level, assessed the proposed benefits for Greenville, SC, examined the risks involved in moving forward with an emerging mobility technology, and determined the governing safety protocols and standards that are applicable to the space. These mini-case studies, though centered on Swyft Cities aerial automated gondola technology, are highly transferable to any type of new mobility technology and lays out a repeatable process for assessing new technology within an city or community context.

33 ADVANCED PROPULSION SYSTEMS↗

Station Impact Analysis 2025

As part of the U.S. DOE EVs@Scale consortium, the NextGen Profiles (NGP) project presents analysis and results from the study of High Power Charging Electric Vehicles and Battery Charging Infrastructure. High Power Charging equipment is capable of recharging electric vehicle traction batteries at power levels of 200KW and above. The intent of the project is to further understand the most recent technological capabilities of the electric mobility industry related to charging performance. The project aims to develop EV, EVSE, and Fleet characterization testing practices and comprehensive analysis with inputs from key industry stakeholders. The results published in this NextGen Profiles project report provide data and insight for use by numerous entities including modeling and simulation organizations, policy makers, fleet planners, industry stakeholders and the general public involved with the development, deployment and operation of electrified transportation technologies. The factors influencing Electric Vehicle (EV) Direct Current Fast Charging (DCFC), including EV battery specifications, temperature effects on lithium-ion battery and power electronics performance, lithium-ion battery SOC bounding and charging station design considerations are specifically investigated to analyze their impacts on charging station operation and recommendations are made to minimize charge station dwell time, reduce charging costs and mitigate electric grid and charge station congestion. Additional high-power charging results are anticipated in future publications in support of the U.S. DOE EVs@Scale consortium NextGen Profiles project.

33 ADVANCED PROPULSION SYSTEMS↗

Use of Digital Real-Time Simulation and Optimization to Identify Maximum Real Power Injection on Banshee Distribution Network

This study investigates the hosting capacity of the Banshee Distribution Network by optimizing the real power injection at carefully selected Distributed Energy Resource (DER) locations. The analysis is conducted within the framework of power system operational constraints, including bus voltage ranges, thermal line ratings, and transformer loading limits. A Python-based Genetic Algorithm (GA), implemented using the PyGAD library, is employed to iteratively identify the optimal power injection configuration that maximizes network utilization while preserving system reliability. The methodology integrates a real-time simulation environment using the Real-Time Digital Simulator (RTDS), allowing high-fidelity evaluation of power flow and voltage behavior under each proposed injection scenario. By coupling the optimization algorithm with real-time simulation feedback, this approach ensures that both static and dynamic constraints are enforced during the evaluation process. The GA leverages evolutionary operators such as selection, crossover, and mutation to navigate the nonlinear search space efficiently. The results of the study delineate the feasible hosting capacity at three targeted buses, reflecting maximum real power levels that can be injected without causing voltage violations, transformer overloading, or line congestion. These findings provide a decision- support tool for distribution planners and utilities aiming to integrate higher penetrations of DERs in existing infrastructure. Additionally, the work lays the foundation for extending such optimization techniques to multi-objective formulations, including economic dispatch and reactive power coordination, in future studies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Precursor Analysis Report: SQL Slammer Worm Infection of Davis-Besse Nuclear Power Plant 2003

The SQL Slammer Worm Infection of Davis-Besse Nuclear Power Plant 2003 Precursor Analysis Report leverages publicly available information about Davis-Besse’s 2003 cyber attack and catalogs anomalous observables for each technique employed in the attack. This analysis is based upon the methodology of the Cybersecurity for the Operational Technology Environment (CyOTE) program. On 25 January 2003, the SQL Slammer worm infected more than 90% of vulnerable hosts and crashed the internet in 10 to 15 minutes, making it one of the fastest spreading worms in history. SQL Slammer is a fileless, memory-resident worm that remotely exploits a stack-based buffer overflow vulnerability on local hosts to intensively scan and rapidly self-propagate across the internet. The worm infected approximately 300,000 unpatched hosts running Microsoft Structured Query Language (SQL) Server 2000 or Microsoft Desktop Engine (MSDE) 2000 with SQL Server Resolution Service. The SQL Slammer worm indirectly infected FirstEnergy’s Davis-Besse nuclear power plant by first infecting a consultant’s company network server and then propagating through an external misconfigured connection into Davis-Besse’s site network. The infection caused major network congestion, slow performance, data overloads, and the inability of local hosts to communicate with each other, which eventually caused a loss of availability and a loss of view when the Safety Parameter Display System (SPDS) and Plant Process Computer (PPC) crashed. At the time of the infection, the plant was already offline, the digital monitoring systems had redundant analog backups, and the plant control and safety functions were not affected, so there were no concerns of a safety breach. However, this incident resulted in many lessons learned and spawned important discussions about cybersecurity’s role in nuclear safety and electric power reliability regulation, policy, and guidance. Researchers and analysts identified 10 unique techniques utilized during the attack with a total of 640 observables using MITRE ATT&CK® for Industrial Control Systems. The CyOTE program assesses observables accompanying techniques used prior to the triggering event to identify opportunities to detect malicious activity. If observables accompanying the attack techniques are perceived and investigated prior to the triggering event, earlier comprehension of malicious activity can take place. Eight of the identified techniques used during Davis-Besse cyber attack were precursors to the triggering event. Analysis identified 596 observables associated with these precursor techniques, 428 of which were assessed to have an increased likelihood of being perceived in the 331 days preceding the triggering event. The response and comprehension time could have been reduced if the observables had been identified earlier. The information gathered in this report contributes to a library of observables tied to a repository of artifacts, data sources, and technique detection references for practitioners and developers to support the comprehension of indicators of attack. Asset owners and operators can use these products if they experience similar observables or to prepare for comparable scenarios.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Potential of Data Center Controls in Grid Services

The rapid proliferation of large data centers brings both challenges and opportunities for grid reliability. The data center resources and their potential flexibility have the potential to contribute resources to grid operations. Through capabilities like energy shifting and resource coordination, data centers can help reduce their net demand on the transmission network, as well as provide additional grid services to support reliable operation on the grid. While transient and long-term grid planning and operations are the scenarios that draw most attention, the quasi-steady state timeseries (QSTS) operation of data centers and grid bring interesting scenarios that can help evaluate the data center controls to aid grid services. This work is focused on modeling data centers for QSTS applications – incorporating the AI data center load profiles and building on the PNNL digital twin model for the thermal management loads to enable simulation studies to reveal the impact of data center controls on grid performance. This includes the integration of a QSTS battery and natural gas generator model to incorporate local resource impacts to the system. The simulation study is performed with a modified IEEE 24-Bus transmission system. Scenarios are focused on evaluating the data center load impacts on the transmission system and leveraging both data center and local generation controls to mitigate those impacts and provide additional grid services. The data center controls revealed the ability to contribute to two main kinds of grid services: preventing congestion on a weak grid by coordinating the data center resources with the collocated BESS and onsite generation; and the ability to help the grid operations during stressed times of operation like during a contingency. Leveraging these and other capabilities has the potential to help data centers become grid responsive assets, aiding in both their integration into the power system and grid reliability.

power grid simulation↗

Privacy-Preserving Transactive Energy System

In this paper, the privacy issue of recently proposed transactive energy systems for electric power systems is studied for the first time. It is identified that the private information of individual market participants is subject to the risk of leakage during their market-based interaction. In order to protect their privacy, a homomorphic encryption-based approach is developed to achieve the privacy preservation with the Paillier encryption scheme. The proposed privacy-perserving design is then demonstrated on a transactive energy system that coordinates and controls residential air conditioners to manage the feeder congestion. The simulation results confirm the effectiveness of the proposed design in protecting the privacy of individual market participants without affecting the overall system performance. Future work on the proposed design is also suggested.

Lu, Yang↗

Substation-Level Grid Topology Optimization Using Bus Splitting

Operations of substation circuit breakers are important for maintenance needs and topology reconfiguration in power systems. Bus splitting is one type of topology change where the two bus bars at a substation can become electrically disconnected under certain actions of circuit breakers. Because these events involve detailed substation modeling, they are typically not considered in routine power system operation and control. In this paper, an improved substation-level topology optimization framework is developed by expanding traditional line switching decisions by breaker-level bus splitting, which can further reduce grid congestion and generation costs. A tight McCormick relaxation is proposed to reformulate the bilinear terms in the resultant optimization problem to linear inequality constraints. Thus, a tractable mixed-integer linear program reformulation is attained that allows for efficient solutions in real-time operations. Numerical studies on the IEEE 14-bus and 118-bus systems demonstrate the computational performance and economic benefits of the proposed topology optimization approach.

bus split↗