Search NASA⌕ Search

SEARCH · Search NASA

Results for “CONVENTIONAL RADIATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Modification of terahertz emission spectrum using microfabricated spintronic emitters

Terahertz (THz) radiation with sub-millimeter wavelength falls in the gap between optical and radio frequencies. Conventional THz emitters do not intertwine with spin degrees of freedom. However, it was recently shown that broadband THz radiation can be efficiently created also by exploiting spin-based effects on ultrafast time scales. Here, we demonstrate the generation and control of THz radiation from microstructured spintronic THz emitters based on the inverse spin-Hall effect. Using time-domain THz spectroscopy, we compare the THz spectra of different stripe patterns made of Fe/Pt bilayers with a spectrum obtained from an extended Fe/Pt bilayer film. It is found that the THz spectrum can be altered by a proper choice of the microstructure dimensions. The experimentally observed spectra are interpreted in terms of a simplified multi-slit interference model, which captures the main experimental features. Our results pave the way for an efficient control of THz light emitted from magnetic heterostructures. This is a crucial step forward for the design and realization of directional THz sources.

Wu, Weipeng↗

A Novel Platform for Evaluating Dose Rate Effects on Oxidative Damage to Peptides: Toward a High-Throughput Method to Characterize the Mechanisms Underlying the FLASH Effect

High dose rate radiation has gained considerable interest recently as a possible avenue for increasing the therapeutic window in cancer radiation treatment. The sparing of healthy tissue at high dose rates relative to conventional dose rates, while maintaining tumor control, has been termed the FLASH effect. Although the effect has been validated in animal models using multiple radiation sources, it is not yet well understood. Here, in this work, we demonstrate a new experimental platform for quantifying oxidative damage to protein sidechains in solution as a function of radiation dose rate and oxygen availability using liquid chromatography mass spectrometry. Using this reductionist approach, we show that for both X-ray and electron sources, isolated peptides in solution are oxidatively modified to different extents as a function of both dose rate and oxygen availability. Our method provides an experimental platform for exploring the parameter space of the dose rate effect on oxidative changes to proteins in solution.

61 RADIATION PROTECTION AND DOSIMETRY↗

Exploring radiation induced segregation mechanisms at grain boundaries in equiatomic CoCrFeNiMn high entropy alloy under heavy ion irradiation

High entropy alloys have gained significant interest due to several unique properties including enhanced radiation resistance. Here, radiation induced segregation, a key phenomenon observed in alloys under irradiation, is examined for the first time at high angle grain boundaries under Ni heavy ion irradiation in the CoCrFeNiMn alloy. Our experimental study indicates significant Mn depletion and Co and Ni enrichment at grain boundaries. The segregation is discussed in the context of a proposed vacancy dominated radiation induced segregation mechanism and compared to existing models in conventional single core component alloys including stainless steels.

36 MATERIALS SCIENCE↗

Extracorporeal adsorption therapy: A Method to improve targeted radiation delivered by radiometal-labeled monoclonal antibodies.

Many investigators have demonstrated the ability to treat hematologic malignancies with radiolabeled monoclonal antibodies targeting hematopoietic antigens such as anti-CD20 and anti-CD45. [1-5] Although the remission rates achieved with radioimmunotherapy (RIT) are relatively high, many patients subsequently relapse presumably due to suboptimal delivery of enough radiation to eradicate the malignancy. The dose-response of leukemia and lymphoma to radiation has been proven. Substantial amounts of radiation can be delivered by RIT if followed by hematopoietic cell transplantation to rescue the bone marrow from myeloablation.[ref] However, the maximum dose of RIT that can be used is still limited by toxicity to normal tissues affected by nonspecific delivery of radiation. Efforts to improve RIT focus on improving the therapeutic ratios of radiation in target versus non-target tissues by removing the fraction of radioisotope that fails to bind to target tissues and circulates freely in the bloodstream perfusing non-target tissues. Our group and others have explored several alternatives for removal of unbound circulating antibody. [refs] One such method, extracorporeal adsorption therapy (ECAT) consists of removing unbound antibody by a method similar to plasmapheresis after critical circulation time and distribution of antibody into target tissues have been achieved. Preclinical studies of ECAT in murine xenograft models demonstrated significant improvement in therapeutic ratios of radioactivity. Chen and colleagues demonstrated that a 2-hour ECAT procedure could remove 40 to 70% of the radioactivity from liver, lung and spleen. [ref] Although isotope concentration in the tumor was initially unaffected, a 50% decrease was noted approximately 36 hours after the procedure. This approach was also evaluated in a limited phase I pilot study of patients with refractory B-cell lymphoma. [ref] After radiographic confirmation of tumor localization of a test dose of anti-CD20 antibody labeled with indium-111 (111In), seven patients received RIT with anti-CD20 antibody labeled with indium-111 for biokinetics and dosimetry, and therapeutic doses of antibody labeled with yttrium-90 (90Y). Performing the ECAT procedure at a rate that such that one blood volume per hour were circulated for 3 hours, resulted in mean radioactivity depletion of 96% in whole blood, 49% in whole body 49%, 62% in the lungs and 40% in liver and kidneys. There was no sufficient data to determine whether there was an improvement in the relative delivery of radiation to the tumor compared to normal organs by performing ECAT, but pharmacokinetic modeling studies suggested a potential therapeutic advantage using this approach. [refs] To evaluate the potential therapeutic advantages of ECAT, we performed biodistribution studies in nonhuman primates comparing the therapeutic ratios of radiation delivered using this approach to those delivered by conventional RIT alone. In addition, we evaluated lutetium-177 (177Lu) as an alternative isotope to optimize the delivery of RIT by improving the therapeutic index (target to non-target ratio)

60 APPLIED LIFE SCIENCES↗

Deacy of quark-antiquark mesons in NRQCD formalism

We investigate the decay properties of the quark-antiquark cc-bar system using NRQCD formalism. The basic parameters for the decay of the cc-bar states are obtained from phenomenological potential scheme of the type V(r) = -({alpha}{sub c}/r)+Ar{sup {nu}}, with {nu} varying from 0.5 to 2, which is employed to fit the low lying spectra. The resultant wave function and mass parameters are employed to determine the decay constants f{sub P/V} with and without QCD corrections. By incorporating the relativistic corrections of order {nu}{sup 4} to the heavy quarkonium decays into two photons, and the vector state into lepton pairs are computed within the NRQCD formalism. These decay widths are also investigated by incorporating radiative corrections up to the lowest order to the conventional Van Royen- Weisskopf formula. Our theoretical predictions of the decays of the cc-bar meson for the potential index around 0.7 are comparable with other model predictions and with the experimental values.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Lymphocyte-Sparing Effect of Stereotactic Body Radiation Therapy in Patients With Unresectable Pancreatic Cancer

Purpose: Radiation-induced lymphopenia (RIL) is associated with inferior survival in patients with glioblastoma, lung cancer, and pancreatic cancer. We asked whether stereotactic body radiation therapy (SBRT) decreases severity of RIL compared to conventional chemoradiation therapy (CRT) in locally advanced pancreatic cancer (LAPC). Methods and Materials: Serial total lymphocyte counts (TLCs) from patients enrolled in a prospective trial of SBRT for LAPC were compared to TLCs from an existing database of LAPC patients undergoing definitive CRT. SBRT patients received 33 Gy (6.6 Gy × 5 fractions). CRT patients received a median dose of 50.4 Gy (1.8 Gy × 28 fractions) with concurrent 5-fluorouracil (77%) or gemcitabine (23%) therapy. Univariate and multivariate analyses (MVA) were used to identify associations between clinical factors and post-treatment TLC and between TLC and survival. Results: Thirty-two patients received SBRT and 101 received CRT. Median planning target volume (PTV) was smaller in SBRT (88.7 cm{sup 3}) than in CRT (344.6 cm{sup 3}; P<.001); median tumor diameter was larger for SBRT (4.6 cm) than for CRT (3.6 cm; P=.01). SBRT and CRT groups had similar median baseline TLCs. One month after starting radiation, 71.7% of CRT patients had severe lymphopenia (ie, TLC <500 cells/mm{sup 3} vs 13.8% of SBRT patients; P<.001). At 2 months, 46.0% of CRT patients remained severely lymphopenic compared with 13.6% of SBRT patients (P=.007). MVA demonstrated that treatment technique and baseline TLCs were significantly associated with post-treatment TLC at 1 but not 2 months after treatment. Higher post-treatment TLC was associated with improved survival regardless of treatment technique (hazard ratio [HR] for death: 2.059; 95% confidence interval: 1.310-3.237; P=.002). Conclusions: SBRT is associated with significantly less severe RIL than CRT at 1 month in LAPC, suggesting that radiation technique affects RIL and supporting previous modeling studies. Given the association of severe RIL with survival in LAPC, further study of the effect of radiation technique on immune status is warranted.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Step in Understanding the Hubble Tension

As cosmological data have improved, tensions have arisen. One such tension is the difference between the locally measured Hubble constant H 0 and the value inferred from the cosmic microwave background (CMB). Interacting radiation has been suggested as a solution, but studies show that conventional models are precluded by high-ℓ CMB polarization data. It seems at least plausible that a solution may be provided by related models that distinguish between high- and low-ℓ multipoles. When interactions of strongly-coupled radiation are mediated by a force-carrier that becomes non-relativistic, the dark radiation undergoes a "step" in which its relative energy density increases as the mediator deposits its entropy into the lighter species. If this transition occurs while CMB-observable modes are inside the horizon, high- and low-ℓ peaks are impacted differently, corresponding to modes that enter the horizon before or after the step. Here, these dynamics are naturally packaged into the simplest supersymmetric theory, the Wess-Zumino model, with the mass of the scalar mediator near the eV-scale. We investigate the cosmological signatures of such "Wess-Zumino Dark Radiation" (WZDR) and find that it provides an improved fit to the CMB alone, favoring larger values of H 0 . If supernovae measurements from the SH0ES collaboration are also included in the analysis, the inferred value of H 0 is yet larger, but the preference for dark radiation and the location of the transition is left nearly unchanged. Utilizing a standardized set of measures, we compare to other models and find that WZDR is among the most successful at addressing the H 0 tension and the best of those with a Lagrangian formulation.

79 ASTRONOMY AND ASTROPHYSICS↗

Using AI/ML to Address Satellite Cloud Remote Sensing Challenges

Various AI/ML tools, employed within the Clouds and the Earth's Radiant Energy System (CERES) Satellite Cloud and Radiation Property retrieval System (SatCORPS) project, are being used to mitigate satellite radiance artifacts and thereby yield more accurate cloud and radiation data products. Neural network and K-nearest neighbor approaches have been developed that enable us to better address common passive satellite remote sensing challenges, such as corrupted imagery, day/night cloud property discontinuities, solar terminator artifacts, inadequate knowledge of the land surface emission temperature (i.e., skin temperature), and poor assumptions about vertical cloud structure, that have otherwise proven difficult to solve using more conventional methods. Fixing these problems promotes a more consistent Earth radiation budget record. These efforts demonstrate effective use of AI/ML architecture to exploit complex, multivariate predictor relationships and produce usable output at satellite spatial and temporal resolutions that would otherwise be ignored or have large biases.

Benjamin Scarino↗

Generation of tunable laser sidebands in the far-infrared region

In recent years, several techniques have been developed for the generation of tunable coherent radiation at submillimeter and far-infrared (FIR) wavelengths. The harmonic generation of conventional microwave sources has made it possible to produce spectrometers capable of continuous operation to above 1000 GHz. However, the sensitivity of such instruments drops rapidly with frequency. For this reason, a great deal of attention is given to laser-based methods, which could cover the entire FIR region. Tunable FIR radiation (approximately 100 nW) has been produced by mixing FIR molecular lasers and conventional microwave sources in both open and closed mixer mounts. The present investigation is concerned with improvements in this approach. These improvements provide approximately thirty times more output power than previous results.

Farhoomand, J.↗

Measurement of LET distribution and dose equivalent on board the space shuttle STS-65

Space radiation dosimetry measurements have been made on board the Space Shuttle STS-65 in the Second International Microgravity Laboratory (IML-2). In these measurements, three kinds of detectors were used; one is a newly developed active detector telescope called "Real-time Radiation Monitoring Device (RRMD)" utilizing silicon semi-conductor detectors and others are conventional detectors of thermoluminescence dosimeters (TLDs) and CR-39 plastic track detectors. Using the RRMD detector, the first attempt of real-time monitoring of space radiation has been achieved successfully for a continuous period of 251.3 h, giving the temporal variations of LET distribution, particle count rates, and rates of absorbed dose and dose equivalent. The RRMD results indicate that a clear enhancement of the number of trapped particles is seen at the South Atlantic Anomaly (SAA) without clear enhancement of dose equivalent, while some daily periodic enhancements of dose equivalent due to high LET particles are seen at the lower geomagnetic cutoff regions for galactic cosmic ray particles (GCRs). Therefore, the main contribution to dose equivalent is seen to be due to GCRs in this low altitude mission (300 km). Also, the dose equivalent rates obtained by TLDs and CR-39 ranged from 146.9 to 165.2 microSv/day and the average quality factors from 1.45 to 1.57 depending on the locations and directions of detectors inside the Space-lab at this highly protected orbit for space radiation with a small inclination (28.5 degrees) and a low altitude (300 km). The LET distributions obtained by two different detectors, RRMD and CR-39, are in good agreement in the region of 15-200 keV/mm and difference of these distributions in the regions of LET < 15 keV/mm and LET > 200 keV/mm can be explained by considering characteristics of CR-39 etched track formation especially for the low LET tracks.

manned↗

Disappearance and recovery of luminescence in GdPO{sub 4}:Eu{sup 3+} nanorods: Propose to water/OH{sup Bullet} release under near infrared and gamma irradiations

Luminescence intensity of rare-earth doped materials can be varied depending on shape of particles, capping agent, and heat-treatment. This is related to the non-radiative rate possessed by the material. Here, we observed the high quenching of the luminescence intensity of Eu{sup 3+} doped GdPO{sub 4} prepared in water (H{sub 2}O) medium. On the contrary, in ethylene glycol (EG) medium, it shows high luminescence. Luminescence intensity is recovered when Eu{sup 3+} doped GdPO{sub 4} nanorods prepared in H{sub 2}O medium is heated above 700 Degree-Sign C. This transforms hexagonal to monoclinic structure following the removal of water. Luminescence intensity is enhanced by changing the medium from H{sub 2}O to D{sub 2}O and also if core-shell formation occurs. Also, we found significant variation in bending and stretching vibrations of O-H and microstructure in this material prepared in H{sub 2}O and EG. Two types of O-H stretching frequencies are observed at 3450 and 3520 cm{sup -1} in H{sub 2}O medium prepared sample which are assigned to the O-H having the hydrogen bonding (surface water) and the confined water, respectively. The formation of nanorods is due to the presence of water on the surface of particles or/and inside the pores of compound. The available water in the nanoparticles pores can be utilized for the efficient killing of mass cells tumor by generating reactive free radicals (H{sup {center_dot}} and OH{sup {center_dot}}) through the application of laser near infrared (NIR) source and the subsequent irradiation of gamma ray. This proposed mechanism is quite different from the conventional treatment of mass cell/malignant tumor using gamma ray radiation. Sample is highly paramagnetic and it will be useful for magnetic resonance imaging contrast agent.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Irradiation route to aqueous synthesis of highly luminescent ZnSe quantum dots and its function as a copper ion fluorescence sensor

Highlights: • Radiation chemical technique can provide a useful route for synthesis of ZnSe QDs. • Chelating nature of ethylene diamine is exploited for capping nanoparticles. • ZnSe QDs can be a suitable sensitive alternative to toxic cadmium-based system. • Cu(II) ion is probed by QDs in the presence of other physiologically relevant ions. - Abstract: Size-controlled synthesis of stable ZnSe QDs with narrow distribution in aqueous environment through conventional soft chemical method still poses a challenge. The proposed radiation assisted strategy demonstrates aqueous synthesis of stable, monodisperse and luminescent ZnSe QDs capped with chelating ethylene diamine under ambient conditions and at room temperature. Radiation chemical method facilitates in slow and in-situ release of selenium ion from sodium selenosulfate. The concentrations of precursors, such as zinc salt, selenium source, ethylene diamine and absorbed radiation (7–90 kGy) dose were optimized for obtaining good quality particles. Selective quenching of luminescence of as-synthesized quantum dots (QDs) by Cu{sup 2+} ions vis-à-vis other physiologically important cations provide evidence for use of ZnSe quantum dots as alternative to toxic Cd-based quantum dots to probe Cu{sup 2+} ions. The linear relation of ratio of loss in emission intensity as a function of concentration of Cu(II) indicates detection limit in nano-molar range.

36 MATERIALS SCIENCE↗

TU-H-BRA-05: A System Design for Integration of An Interior MRI and a Linear Accelerator

Purpose: MRI is a highly desirable modality to guide radiation therapy but it is difficult to combine a conventional MRI scanner directly with a linear accelerator (linac). An interior MRI (iMRI) concept has been proposed to acquire MRI images within a small field of view only covering targets and immediate surrounding tissues. The objective of this project is to design an interior MRI system to work with a linac using a magnet to provide a field around 0.2T in a cube of 20cm per side, and perform image reconstruction with a slightly inhomogeneous static magnetic fields. Methods: All the results are simulated using a commercially available software package, FARADY. In our design, a ring structure holds the iMRI system and also imbeds a linac treatment head. The ring is synchronized to the linac gantry rotation. Half of the ring is made of steel and becomes a magnetic flux return path (yoke) so that a strong magnetic field will be limited inside the iron circuit and fringe fields will be very weak. In order to increase the static magnetic field homogeneity, special steel magnet boots or tips were simulated. Three curved boots were designed based on two-dimensional curves: arc, parabola and hyperbola. Results: Different boot surfaces modify magnetic field distributions differently. With the same pair of neodymium-iron-boron (NdFeB) magnets, the magnetic induction at the centers are 0.217T, 0.201T, 0.204T, and 0.212T for flat, arc, parabola and hyperbola boots, respectively. The hyperbola boots lead to the most homogeneous results, the static magnetic field deviations are within 0.5% in a cube of 20cm, and can be further improved using shimming techniques. Conclusion: This study supports the concept of an iMRI design. Successful development of iMRI will provide crucial information for tumor delineation in radiation therapy.

43 PARTICLE ACCELERATORS↗

Influence of solidification structures on radiation-induced swelling in an additively-manufactured austenitic stainless steel

Metal additive manufacturing offers potential advantages for producing structural materials, such as austenitic stainless steels, in nuclear power systems. However, the microstructure developed during metal additive processing is notably different from the one developed in conventional processing, and the influence of the microstructural differences on performance in radiation environments has not been fully quantified. Using heavy ion irradiation and transmission electron microscopy, the radiation-induced swelling response of a laser powder-bed fusion-manufactured austenitic stainless steel was investigated at high doses. The influence of solidification-induced dislocation and precipitate structures was studied by comparing the radiation-induced swelling response of a 316L stainless steel in three microstructural states: as-fabricated, solution annealed, and fully recrystallized. Void swelling was approximately twice as pronounced in the as-fabricated state compared to post-processed states. In the framework of the rate theory for radiation effects, the higher swelling in the as-fabricated state can be explained by the strong sink bias for interstitial point defects exerted by the intermediate density of pre-existing dislocations. Void swelling was inhibited in the vicinity of pre-existing precipitates, but the density of precipitates in the as-fabricated material was not enough to compensate for the increase in swelling caused by dislocations.

36 MATERIALS SCIENCE↗

BiFeO(3): Synchrotron Radiation Structure Refinement And Magnetoelectric Geometry

Presently BiFeO{sub 3} focuses attention due to its multiferroic nature. This phase shows a highly distorted perovskite crystal structure, with R3c crystal symmetry. Details of the crystallographic structure are required input for a detailed explanation of its remarkable magnetoelectric properties. Present report contributes a high-resolution synchrotron radiation diffraction analysis of the BiFeO{sub 3} crystal structure. Single-phased sample was obtained by conventional solid-state reaction under bismuth atmosphere. XRD experiment was performed on beamline 2-1, Stanford Synchrotron Radiation Laboratory, with 12 keV X-rays. For data Rietveld processing, Fullprof software package was applied. Obtained cell parameters (in {angstrom}, hexagonal system description) were a = 5.57414(4); c = 13.85882(12). Group-theoretical analysis of BiFeO{sub 3} linear magnetoelectric tensor is presented. Only transverse effect is allowed by symmetry. Axial-symmetry polycrystal ceramics cannot show linear magnetoelectric coupling.

36 MATERIALS SCIENCE↗

A study of respiration-correlated cone-beam CT scans to correct target positioning errors in radiotherapy of thoracic cancer

Purpose: There is increasingly widespread usage of cone-beam CT (CBCT) for guiding radiation treatment in advanced-stage lung tumors, but difficulties associated with daily CBCT in conventionally fractionated treatments include imaging dose to the patient, increased workload and longer treatment times. Respiration-correlated cone-beam CT (RC-CBCT) can improve localization accuracy in mobile lung tumors, but further increases the time and workload for conventionally fractionated treatments. This study investigates whether RC-CBCT-guided correction of systematic tumor deviations in standard fractionated lung tumor radiation treatments is more effective than 2D image-based correction of skeletal deviations alone. A second study goal compares respiration-correlated vs respiration-averaged images for determining tumor deviations. Methods: Eleven stage II-IV nonsmall cell lung cancer patients are enrolled in an IRB-approved prospective off-line protocol using RC-CBCT guidance to correct for systematic errors in GTV position. Patients receive a respiration-correlated planning CT (RCCT) at simulation, daily kilovoltage RC-CBCT scans during the first week of treatment and weekly scans thereafter. Four types of correction methods are compared: (1) systematic error in gross tumor volume (GTV) position, (2) systematic error in skeletal anatomy, (3) daily skeletal corrections, and (4) weekly skeletal corrections. The comparison is in terms of weighted average of the residual GTV deviations measured from the RC-CBCT scans and representing the estimated residual deviation over the treatment course. In the second study goal, GTV deviations computed from matching RCCT and RC-CBCT are compared to deviations computed from matching respiration-averaged images consisting of a CBCT reconstructed using all projections and an average-intensity-projection CT computed from the RCCT. Results: Of the eleven patients in the GTV-based systematic correction protocol, two required no correction, seven required a single correction, one required two corrections, and one required three corrections. Mean residual GTV deviation (3D distance) following GTV-based systematic correction (mean {+-} 1 standard deviation 4.8 {+-} 1.5 mm) is significantly lower than for systematic skeletal-based (6.5 {+-} 2.9 mm, p= 0.015), and weekly skeletal-based correction (7.2 {+-} 3.0 mm, p= 0.001), but is not significantly lower than daily skeletal-based correction (5.4 {+-} 2.6 mm, p= 0.34). In two cases, first-day CBCT images reveal tumor changes-one showing tumor growth, the other showing large tumor displacement-that are not readily observed in radiographs. Differences in computed GTV deviations between respiration-correlated and respiration-averaged images are 0.2 {+-} 1.8 mm in the superior-inferior direction and are of similar magnitude in the other directions. Conclusions: An off-line protocol to correct GTV-based systematic error in locally advanced lung tumor cases can be effective at reducing tumor deviations, although the findings need confirmation with larger patient statistics. In some cases, a single cone-beam CT can be useful for assessing tumor changes early in treatment, if more than a few days elapse between simulation and the start of treatment. Tumor deviations measured with respiration-averaged CT and CBCT images are consistent with those measured with respiration-correlated images; the respiration-averaged method is more easily implemented in the clinic.

60 APPLIED LIFE SCIENCES↗

{sup 99}Mo Production at KIPT Neutron Source Facility

Argonne National Laboratory (ANL) and Kharkov Institute of Physics and Technology (KIPT) have cooperated on the construction of the Neutron Source Facility (NSF) at KIPT, Kharkov (Ukraine). The NSF facility consists of an electron accelerator driven system (ADS) generating 300 kW of thermal power for multiple applications, including medical isotope production. ANL performed extensive analyses including medical isotopes production, reactivity monitoring, operations and control, refueling, cold neutron source design, target design,and radiation shielding. The present study focuses on the use of the KIPT NSF for medical isotope production. Medical isotopes are radioactive isotopes with short half-lives used in diagnostic and therapeutic medical procedures. For example, brain cancer is difficult to treat by ordinary surgery and only brachytherapy with {sup 131}Cs, which has 9.7 days half-life, has shown effective results on the patients. {sup 99m}Tc is the most common medical isotope used in medical diagnoses because the wavelength of its gamma radiation (8.8 pm) is about the same as the conventional X-ray diagnostic devices. {sup 99m}Tc has 6 hours half-life, therefore it cannot be stored because it decays into {sup 99}Tc. The parent of {sup 99m}Tc is {sup 99}Mo, which has 66 hours half-life. Consequently, the delivery of {sup 99m}Tc occurs through shipping {sup 99}Mo samples to the medical facilities. The Neutron Source Facility of KIPT is the first ADS in the world operating at non-zero power and allows producing several isotopes for medical applications. The total power of the facility is about 300 kW, including ∼200 kW from fission reactions. The construction of the NSF has been already completed and operations will start during year 2016. After 20 irradiation days, {sup 82}Br, {sup 64}Cu, {sup 165}Dy, {sup 166}Ho, {sup 192}Ir, {sup 194}Ir, {sup 186}Re, {sup 188}Re and {sup 153}Sm have specific activities, larger than 100 MBq/mg without taking into account the self-shielding effect and therefore they are good candidates for production. The self-shielding effect plays an important role for all nuclide parents that have a large microscopic capture cross section. This effect reduces the reaction rate and therefore the specific activity. For instance, the analyses of molybdenum trioxide (MoO{sub 3}) irradiation samples have shown that the self-shielding effect may reduce the specific activity by a factor 1.4. The metallic form of natural molybdenum produces a higher specific activity, relative to the trioxide form. Analyses on the 6-day Ci {sup 99}Mo activity have shown that is possible to perform between 40 to 310 {sup 99m}Tc medical procedures per MoO{sub 3} irradiation week. The number of medical procedures depends on the diagnosed organ and the weight of the patient. (authors)

07 ISOTOPE AND RADIATION SOURCES↗

Protein Characterisation by Synchrotron Radiation Circular Dichroism (SRCD) Spectroscopy

Circular dichroism (CD) spectroscopy is a well-established technique for the study of proteins. Synchrotron radiation circular dichroism (SRCD) spectroscopy extends the utility of conventional CD spectroscopy (i.e. using laboratory-based instruments) because the high light flux from a synchrotron enables collection of data to lower wavelengths, detection of spectra with higher signal-to-noise levels and measurements in the presence of strongly absorbing non-chiral components such as salts, buffers, lipids and detergents. This review describes developments in instrumentation, methodologies and bioinformatics that have enabled new applications of the SRCD technique for the study of proteins. It includes examples of the use of SRCD spectroscopy for providing static and dynamic structural information on molecules, including determinations of secondary structures of intact proteins and domains, assessment of protein stability, detection of conformational changes associated with ligand and drug binding, monitoring of environmental effects, examination of the processes of protein folding and membrane insertion, comparisons of mutant and modified proteins, identification of intermolecular interactions and complex formation, determination of the dispositions of proteins in membranes, identification of natively disordered proteins and their binding partners and examination of the carbohydrate components of glycoproteins. It also discusses how SRCD can be used in conjunction with macromolecular crystallography and other biophysical techniques to provide a more complete picture of protein structures and functions, including how proteins interact with other macromolecules and ligands. This review also includes a discussion of potential new applications in structural and functional genomics using SRCD spectroscopy and future instrumentation and bioinformatics developments that will enable such studies. Finally, the appendix describes a number of computational/bioinformatics resources for secondary structure analyses that take advantage of the improved data quality available from SRCD. In summary, this review discusses how SRCD can be used for a wide range of structural and functional studies of proteins.

59 BASIC BIOLOGICAL SCIENCES↗