Search NASA⌕ Search

SEARCH · Search NASA

Results for “Coherence”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Coherently prepared nondegenerate Y-shaped four-level correlated emission laser: A source of tripartite entangled light

A detailed derivation of the master equation of the cavity radiation of a coherently prepared Y-shaped four-level correlated emission laser is presented. The outline of the procedures that can be employed in analytically solving the stochastic differential equations and the rate equations of various correlations are also provided. It is shown that coherently preparing the atoms in the upper two energy levels and the lower level initially can lead to a genuine continuous-variable tripartite entanglement. Moreover, preparing the atoms in the coherent superposition, other than the possible maximum or minimum, of the upper two energy levels, leaving the lower level unpopulated, may lead to a similar observation. With the possibility of the atom at the intermediate energy level to take three different transition roots guided by the induced coherence, this system, in general, is found to encompass versatile options for practical utilization. In particular, coupling at least one of the dipole forbidden transitions by an external radiation is expected to enhance the degree of detectable entanglement.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Triple photonic band-gap structure dynamically induced in the presence of spontaneously generated coherence

We study a cold atomic sample coherently driven into the five-level triple-{Lambda} configuration for attaining a dynamically controlled triple photonic band-gap structure. Our numerical calculations show that three photonic band gaps with homogeneous reflectivities up to 92% can be induced on demand around the probe resonance by a standing-wave driving field in the presence of spontaneously generated coherence. All these photonic band gaps are severely malformed with probe reflectivities declining rapidly to very low values when spontaneously generated coherence is gradually weakened. The triple photonic band-gap structure can also be attained in a five-level chain-{Lambda} system of cold atoms in the absence of spontaneously generated coherence, which however requires two additional traveling-wave fields to couple relevant levels.

74 ATOMIC AND MOLECULAR PHYSICS↗

Heterodyne coherent anti-Stokes Raman scattering by the phase control of its intrinsic background

We demonstrate the use of femtosecond laser pulse shaping for precise control of the interference between the coherent anti-Stokes Raman scattering (CARS) signal and the coherent nonresonant background generated within the same sample volume. Our technique is similar to heterodyne detection with the coherent background playing the role of the local oscillator field. In our experiment, we first apply two ultrashort (near-transform-limited) femtosecond pump and Stokes laser pulses to excite coherent molecular oscillations within a sample. After a short and controllable delay, we then apply a laser pulse that scatters off of these oscillations to produce the CARS signal. By making fine adjustments to the probe field spectral profile, we vary the relative phase between the Raman-resonant signal and the nonresonant background, and we observe a varying spectral interference pattern. These controlled variations of the measured pattern reveal the phase information within the Raman spectrum.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Coherence of a qubit stored in Zeeman levels of a single optically trapped atom

We experimentally investigate the coherence properties of a qubit stored in the Zeeman substates of the 5{sup 2}S{sub 1/2}, F=1 hyperfine ground level of a single optically trapped {sup 87}Rb atom. Larmor precession of a single atomic spin-1 system is observed by preparing the atom in a defined initial spin state and then measuring the resulting state after a programmable period of free evolution. Additionally, by performing quantum-state tomography, maximum knowledge about the spin coherence is gathered. By using an active magnetic field stabilization and without application of a magnetic guiding field, we achieve transverse and longitudinal dephasing times of T{sub 2}{sup *}=75-150 {mu}s and T{sub 1}>0.5 ms, respectively. We derive the light-shift distribution of a single atom in the approximately harmonic potential of a dipole trap and show that the measured atomic spin coherence is limited mainly by residual position- and state-dependent effects in the optical trapping potential. The improved understanding enables longer coherence times, an important prerequisite for future applications in long-distance quantum communication and computation with atoms in optical lattices, or for a loophole-free test of Bell's inequality.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Coherent population trapping in Raman-pulse atom interferometry

Raman pulse atom interferometry is an important modality for precision measurements of inertial forces and tests of fundamental physics. Typical Raman atom optics use two coherent laser fields applied at gigahertz-scale detunings from optical resonance, so that spontaneous emission produces a minor or negligible source of decoherence. An additional consequence of spontaneous emission is coherent population trapping (CPT). We show that CPT produces coherences and population differences which induce systematic effects in Raman pulse atom interferometers. We do not believe that CPT has been previously identified as an error mechanism in Raman pulse atom interferometry. We present an experimental characterization of CPT coherences and population differences induced in laser-cooled cesium atoms by application of Raman pulses at detunings near 1 GHz, commensurate with detunings used in several precision measurement experiments. We are not aware of previous demonstrations of CPT-induced population difference. We argue that CPT effects could induce phase shifts of several milliradians in magnitude for typical experimental parameters and stipulate that these errors can be suppressed by propagation direction reversal in Raman interferometer-based precision measurements.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Robust Millisecond Coherence Times of Erbium Electron Spins

Erbium doped solids are prime candidates for quantum memories in optical quantum networks given their telecom-compatible photon emission. An electron spin of erbium with millisecond coherence time is desirable for generating remote entanglement between adjacent quantum network nodes. Here, in this study, we report GHz-range electron spin transitions of 167 Er 3+ in yttrium oxide (Y 2 O 3 ) matrix with coherence times that are consistently longer than a millisecond. By polarizing para magnetic impurity spins we achieve a spin T 2 up to 1.46 ms, and up to 7.1 ms after dynamical decoupling. These coherence lifetimes are among the longest found for erbium in crystalline matrices despite the presence of host nuclear spins. We further enhance the coherence time beyond conventional dynamical decoupling, using customized sequences to simultaneously mitigate spectral diffusion and dipolar interactions. Our study not only establishes 167 Er 3+ : Y 2 O 3 as a significant quantum memory platform but also provides a guideline for engineering long-lived erbium spins in a variety of host materials for quantum technologies.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Long-distance coherence of Majorana wires

Theoretically, a pair of Majorana bound states in a topological superconductor forms a single fermionic level even at large separations, implying that the parity information is stored nonlocally. The nonlocality leads to a long-distance coherence for electrons tunneling through a Coulomb-blockaded Majorana wire, an effect that can be observed, e.g., in an interferometer. Here, we examine theoretically the coherent electron transfer, taking into account that tunneling implies the long-distance transfer of charge, which is carried by one-dimensional plasmons. In this work, we show that the charge dynamics does not affect the coherence of the electron tunneling process in a topological superconductor consisting of a semiconductor wire proximitized by a single bulk superconductor. The coherence may be strongly suppressed, however, if the topological superconductivity derives from a semiconductor wire proximitized by a granular superconductor.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Quasiparticle coherence in the nematic state of FeSe

We report electronic nematicity is a ubiquitous phenomenon in iron-based superconductors but its origin is still debated. Most models consider either spin or orbital degrees of freedom as the driving force but typically do not take electronic correlations into account. However, mass enhancements, coherent-incoherent crossovers, and the strong orbital differentiation can only be understood using correlations in a Hund's metal framework. Here, we study the influence of nematicity on the quasiparticle coherence in detwinned FeSe using angle-resolved photoemission spectroscopy (ARPES). We compare photoemission spectral weight from d xz and d yz orbitals in the coherent quasiparticle peak and in the incoherent Hubbard band and find an anisotropy between the two orbitals. We interpret our observation in terms of a more coherent d xz orbital compared to the d yz orbital inside the nematic phase. This result is in contrast to earlier predictions of an incoherent d xz orbital and highlights the importance of electronic correlations in the description of nematicity.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Coherent X-Ray Diffraction Imaging with Nanofocused Illumination

Coherent x-ray diffraction imaging is an x-ray microscopy technique with the potential of reaching spatial resolutions well beyond the diffraction limits of x-ray microscopes based on optics. However, the available coherent dose at modern x-ray sources is limited, setting practical bounds on the spatial resolution of the technique. By focusing the available coherent flux onto the sample, the spatial resolution can be improved for radiation-hard specimens. A small gold particle (size <100 nm) was illuminated with a hard x-ray nanobeam (E=15.25 keV, beam dimensions {approx_equal}100x100 nm{sup 2}) and is reconstructed from its coherent diffraction pattern. A resolution of about 5 nm is achieved in 600 s exposure time.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Probing the Transverse Coherence of an Undulator X-Ray Beam Using Brownian Particles

We present a novel method to map the two-dimensional transverse coherence of an x-ray beam using the dynamical near-field speckles formed by scattering from colloidal particles. Owing to the statistical nature of the method, the coherence properties of synchrotron radiation from an undulator source is obtained with high accuracy. The two-dimensional complex coherence function is determined at the sample position and the imaging optical scheme further allowed us to evaluate the coherence factor at the undulator output despite the aberrations introduced by the focusing optics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Coherent Control of the Exciton-Biexciton System in an InAs Self-Assembled Quantum Dot Ensemble

Coherent control of a strongly inhomogeneously broadened system, namely, InAs self-assembled quantum dots, is demonstrated. To circumvent the deleterious effects of the inhomogeneous broadening, which usually masks the results of coherent manipulation, we use prepulse two-dimensional coherent spectroscopy to provide a size-selective readout of the ground, exciton, and biexciton states. The dependence on the timing of the prepulse is due to the dynamics of the coherently generated populations. To further validate the results, we performed prepulse polarization dependent measurements and confirmed the behavior expected from selection rules. All measured spectra can be excellently reproduced by solving the optical Bloch equations for a 4-level system.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Detecting Multiple Moving Objects in Crowded Environments with Coherent Motion Regions

We propose an object detection system that uses the locationsof tracked low-level feature points as input, and producesa set of independent coherent motion regions as output.As an object moves, tracked feature points on it spana coherent 3D region in the space-time volume defined bythe video. In the case of multi-object motion, many possiblecoherent motion regions can be constructed around theset of all feature point tracks. Our approach is to identifyall possible coherent motion regions, and extract the subsetthat maximizes an overall likelihood function while assigningeach point track to at most one motion region. Wesolve the problem of finding the best set of coherent motionregions with a simple greedy algorithm, and show thatour approach produces semantically correct detections andcounts of similar objects moving through crowded scenes.

99 GENERAL AND MISCELLANEOUS↗

Secure Wireless Communication Using Distributed Coherent Transmission and Spatial Signal Decomposition

We present a new approach to secure wireless communications using coherent distributed transmission of signals that are spatially decomposed between a two-element distributed antenna array. High-accuracy distributed coordination of microwave wireless systems supports the ability to transmit different parts of a signal from separate transmitters such that they combine coherently at a designated destination. In this article, we explore this concept using a two-element coherent distributed phased array where each of the two transmitters sends a separate component of a communication signal, where each symbol is decomposed into a sum of two pseudorandom signal vectors, the coherent summation of which yields the intended symbol. By directing the transmission to an intended receiver using distributed beamforming, the summation of the two vector components is largely confined to a spatial region at the destination receiver. We implement the technique in a $50−λ$ array operating at 3 GHz. We evaluate the symbol error rate (SER) in 2-D space through simulation and measurement, showing that the approach yields a spatially confined secure region where the information is recoverable (i.e., the received signal has low SER), and outside of which the information is unrecoverable (high SER). The proposed system is also compared against a traditional beamforming system where each node sends the same data. We validate experimentally that our approach achieves a low SER of 0.0082 at broadside and an SER above 0.25 at all other locations compared to a traditional beamforming approach that achieves a SER of 0 at all locations measured.

Engineering - Electronic and electrical engineerin↗

Initial Results in Using a Self-Coherence Method for Detecting Sustained Oscillations

This paper develops a self-coherence method for detecting sustained oscillations using phasor measurement unit (PMU) data. Sustained oscillations decrease system performance and introduce potential reliability issues. Timely detection of the oscillations at an early stage provides the opportunity for taking remedial reaction. Using high-speed time-synchronized PMU data, this paper details a self-coherence method for detecting sustained oscillation, even when the oscillation amplitude is lower than ambient noise. Simulation and field measurement data are used to evaluate the proposed method’s performance. It is shown that the proposed method can detect sustained oscillations and estimate oscillation frequencies with a low signal-to-noise ratio. Comparison with a power spectral density method also shows that the proposed self-coherence method performs better. Index Terms—coherence, power spectral density, phasor measurement unit (PMU), oscillations, power system dynamics

Zhou, Ning↗

Quickest Detection for Changes in Maximal kNN Coherence of Random Matrices

This paper addresses the problem of quickest detection of a change in the maximal coherence between columns of a n p random matrix based on a sequence of matrix observations having a single unknown change point. The random matrix is assumed to have identically distributed rows and the maximal coherence is defined as the largest of the ( 2 p) correlation coefficients associated with any row. Likewise the κ nearest neighbor (kNN) coherence is defined as the κ-th largest of these correlation coefficients. The forms of the preand postchange distributions of the observed matrices are assumed to belong to the family of elliptically contoured densities with sparse dispersion matrices but are otherwise unknown. A nonparametric stopping rule is proposed that is based on the maximal kNN sample coherence between columns of each observed random matrix. This is a summary statistic that is related to a test of existence of a hub vertex in a sample correlation graph having degree at least κ. Performance bounds on the delay and false alarm performance of the proposed stopping rule are obtained in the purely high-dimensional regime where p → ∞ and n is fixed. When the prechange dispersion matrix is diagonal it is shown that, among all functions of the proposed summary statistic, the proposed stopping rule is asymptotically optimal under a minimax quickest change detection model as the stopping threshold approaches infinity. Furthermore, the theory developed also applies to sequential hypothesis testing and fixed sample size tests.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Ex vivo evaluation of a coherent normalization procedure to quantify in vivo finger strontium XRS measurements

Purpose: Energy dispersive x-ray fluorescence spectroscopy (XRS) measurements were performed on human cadaver index fingers to measure bone strontium content in the presence of intact overlying soft-tissue. This work assesses the feasibility of applying a normalization procedure including soft-tissue correction of x-ray absorption as a means to quantify an ex vivo bone strontium XRS measurement. Methods: Bone strontium measurements were made using an excitation-detection system incorporating an {sup 125}I x-ray excitation source and an Ortec registered Ametek-AMT Si(Li) detector in 180 deg. backscatter geometry. Spectral processing was accomplished using an in-house nonlinear least-squares Marquardt fitting routine. Bone strontium was quantified using an egs5 Monte Carlo based x-ray soft-tissue correction algorithm in conjunction with the normalization of strontium x-rays to the coherent scatter peaks of 35.5 keV {sup 125}I {gamma}-rays. Results: Comparison of tissue intact and bare bone finger XRS measurement quantification attempts revealed an overall discrepancy of 18.6% that is attributed primarily to the significant contribution of soft-tissue to coherent scatter of 35.5 keV source {gamma}-rays and to a lesser degree, inconsistencies with the simulated tissue correction model. Work toward the beginnings of an experimentally derived tissue correction model, as a means to validate the simulated model, have been reported. Two observations hinted at a systematic inflation of the observed K{beta} peak area. First, strontium concentrations estimated by K{alpha} peak areas were less than the K{beta} peak areas by 28.6% (p < 0.0001) and 10.5% (p < 0.001) for tissue intact and bare bone measurements, respectively. Second, the K{alpha}:K{beta} x-ray average ratios between tissue corrected (3.61 {+-} 0.55) and bare bone predicted (4.4 {+-} 0.4) did not agree (p < 0.0001) and pointed to shortcomings with the current processing treatment of strontium K x-ray peak area extraction. Through finger bone XRS measurements, bone strontium concentration in the Caucasian population was estimated at 95 {+-} 15 {mu}g Sr/g dry bone. Conclusions: The discrepancies observed: between quantification attempts of tissue corrected and bare bone measurements, the inflated estimates of K{beta} relative to K{alpha} peak concentrations and between observed and expected K{alpha}:K{beta} ratios, have indicated that shortcomings with the bone strontium coherent normalization and tissue correction procedure exist. Coherent scatter contribution of soft-tissue overlying bone, tissue correction model limitations, and spectra processing issues are all mentioned as sources of observed discrepancies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cascaded-systems analyses and the detective quantum efficiency of single-Z x-ray detectors including photoelectric, coherent and incoherent interactions

Purpose: Theoretical models of the detective quantum efficiency (DQE) of x-ray detectors are an important step in new detector development by providing an understanding of performance limitations and benchmarks. Previous cascaded-systems analysis (CSA) models accounted for photoelectric interactions only. This paper describes an extension of the CSA approach to incorporate coherent and incoherent interactions, important for low-Z detectors such as silicon and selenium. Methods: A parallel-cascade approach is used to describe the three types of x-ray interactions. The description of incoherent scatter required developing expressions for signal and noise transfer through an 'energy-labeled reabsorption' process where the parameters describing reabsorption are random functions of the scatter photon energy. The description of coherent scatter requires the use of scatter form factors that may not be accurate for some crystalline detector materials. The model includes the effects of scatter reabsorption and escape, charge collection, secondary quantum sinks, noise aliasing, and additive noise. Model results are validated by Monte Carlo calculations for Si and Se detectors assuming free-atom atomic form factors. Results: The new signal and noise transfer expressions were validated by showing agreement with Monte Carlo results. Coherent and incoherent scatter can degrade the DQE of Si and sometimes Se detectors depending on detector thickness and incident-photon energy. Incoherent scatter can produce a substantial low-frequency drop in the modulation transfer function and DQE. Conclusions: A generally useful CSA model of the DQE is described that is believed valid for any single-Z material up to 10 cycles/mm at both mammographic and radiographic energies within the limitations of Fourier-based linear-systems models and the use of coherent-scatter form factors. The model describes a substantial low-frequency drop in the DQE of Si systems due to incoherent scatter above 20-40 keV.

36 MATERIALS SCIENCE↗

SU-F-I-53: Coded Aperture Coherent Scatter Spectral Imaging of the Breast: A Monte Carlo Evaluation of Absorbed Dose

Purpose: Coherent scatter based imaging has shown improved contrast and molecular specificity over conventional digital mammography however the biological risks have not been quantified due to a lack of accurate information on absorbed dose. This study intends to characterize the dose distribution and average glandular dose from coded aperture coherent scatter spectral imaging of the breast. The dose deposited in the breast from this new diagnostic imaging modality has not yet been quantitatively evaluated. Here, various digitized anthropomorphic phantoms are tested in a Monte Carlo simulation to evaluate the absorbed dose distribution and average glandular dose using clinically feasible scan protocols. Methods: Geant4 Monte Carlo radiation transport simulation software is used to replicate the coded aperture coherent scatter spectral imaging system. Energy sensitive, photon counting detectors are used to characterize the x-ray beam spectra for various imaging protocols. This input spectra is cross-validated with the results from XSPECT, a commercially available application that yields x-ray tube specific spectra for the operating parameters employed. XSPECT is also used to determine the appropriate number of photons emitted per mAs of tube current at a given kVp tube potential. With the implementation of the XCAT digital anthropomorphic breast phantom library, a variety of breast sizes with differing anatomical structure are evaluated. Simulations were performed with and without compression of the breast for dose comparison. Results: Through the Monte Carlo evaluation of a diverse population of breast types imaged under real-world scan conditions, a clinically relevant average glandular dose for this new imaging modality is extrapolated. Conclusion: With access to the physical coherent scatter imaging system used in the simulation, the results of this Monte Carlo study may be used to directly influence the future development of the modality to keep breast dose to a minimum while still maintaining clinically viable image quality.

60 APPLIED LIFE SCIENCES↗