Search NASA⌕ Search

SEARCH · Search NASA

Results for “Comparative Study”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Intensity modulated radiotherapy and 3D conformal radiotherapy for whole breast irradiation: a comparative dosimetric study and introduction of a novel qualitative index for plan evaluation, the normal tissue index

We report on a retrospective dosimetric study, comparing 3D conformal radiotherapy (3DCRT) and hybrid intensity modulated radiotherapy (hIMRT). We evaluated plans based on their planning target volume coverage, dose homogeneity, dose to organs at risk (OARs) and exposure of normal tissue to radiation. The Homogeneity Index (HI) was used to assess the dose homogeneity in the target region, and we describe a new index, the normal tissue index (NTI), to assess the dose in the normal tissue inside the tangent treatment portal. Plans were generated for 25 early-stage breast cancer patients, using a hIMRT technique. These were compared with the 3DCRT plans of the treatment previously received by the patients. Plan quality was evaluated using the HI, NTI and dose to OARs. The hIMRT technique was significantly more homogenous than the 3DCRT technique, while maintaining target coverage. The hIMRT technique was also superior at minimising the amount of tissue receiving D{sub 105%} and above (P < 0.0001). The ipsilateral lung and contralateral breast maximum were significantly lower in the hIMRT plans (P < 0.05 and P < 0.005), but the 3DCRT technique achieved a lower mean heart dose in left-sided breast cancer patients (P < 0.05). Hybrid intensity modulated radiotherapy plans achieved improved dose homogeneity compared to the 3DCRT plans and superior outcome with regard to dose to normal tissues. We propose that the addition of both HI and NTI in evaluating the quality of intensity modulated radiotherapy (IMRT) breast plans provides clinically relevant comparators which more accurately reflect the new paradigm of treatment goals and outcomes in the era of breast IMRT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Magnetism and magnetocaloric effect in multicomponent Laves-phase compounds: Study and comparative analysis

This paper presents a review and results of comparative study of the influence of Gd on some physical properties of (R{sub 0.9}R′{sub 0.1}){sub 1−x}Gd{sub x}Co{sub 2} solid solutions with R=Dy, Ho and R′=Er, Ho and x varied from 0.05 to 0.15. Powder X-ray diffraction analysis performed at room temperature revealed that all studied solid solutions solidify with the formation of a Laves-phase MgCu{sub 2}-type structure (space group Fd−3m). The magnetization behavior and the magnetic transition are analyzed in terms of the Landau theory. The studies of magnetic properties and heat capacity showed that a relatively small Gd addition significantly increases T{sub C} of the compounds. The maximum percentage increase in T{sub C}, namely, ∼43% was observed for (Ho{sub 0.9}Er{sub 0.1}){sub 1−x}Gd{sub x}Co{sub 2}. However, the highest temperature was noted for the (Dy{sub 0.9}Ho{sub 0.1}){sub 0.85}Gd{sub 0.15}Co{sub 2} solid solution; it is T{sub C}=183.4 K. Below the ordering temperature, all samples are ferrimagnetically ordered; at high temperatures, they are Curie–Weiss paramagnets. Moreover, a small Gd addition eliminates the field-induced magnetic transition near T{sub C} and, as consequence, transforms the nature of magnetic transition from the first- to second-order. The magnetocaloric effect has been estimated in terms of both isothermal magnetic entropy and adiabatic temperature changes. The highest adiabatic temperature change ΔT{sub ad}=3 K and highest isothermal entropy change ΔS{sub mag}=12.1 J/kg K were observed for (Ho{sub 0.9}Er{sub 0.1}){sub 0.95}Gd{sub 0.05}Co{sub 2} at ∼90 K in magnetic fields of 2 T and 3 T, respectively. A decrease in the entropy change has been observed with increasing Gd content in all studied samples. The smallest values of ΔS{sub mag} were observed for the (Dy{sub 0.9}Ho{sub 0.1}){sub 1−x}Gd{sub x}Co{sub 2} solid solutions. Under an external field change of from 0 to 3 T, the maximum entropy change for (Dy{sub 0.9}Ho{sub 0.1}){sub 1−x}Gd{sub x}Co{sub 2} compounds decreases from 6.9 at x=0.05–4.3 J/kg K at x=0.15. The refrigerant capacity for all solid solutions (with 0.05≤x≤0.15) is reported. The effect of increasing Gd content in the solid solutions on their magnetic and magnetocaloric properties is discussed. - Graphical abstract: Temperature dependencies of ΔT{sub ad} induced by µ{sub 0}H=1 and 2 T in (a) (Ho{sub 0.9}Er{sub 0.1}){sub 1−x}Gd{sub x}Co{sub 2} and (b) (Dy{sub 0.9}Er{sub 0.1}){sub 1−x}Gd{sub x}Co{sub 2} solid solutions. Display Omitted.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Comparison of four MPPT techniques for PV systems

The working behavior of a module / PV array is non-linear and highly dependent on working conditions. As a given condition, there is only one point at which the level of available power at its output is maximum. This point varies with time, enlightenment and temperature. To ensure optimum operation, the use of MPPT control allows us to extract the maximum power. This paper presents a comparative study of four widely-adopted MPPT algorithms, such as Perturb and Observe, Incremental Conductance, Measurements of the variation of the open circuit voltage or of the short-circuit current. Their performance is evaluated using, for all these techniques. In particular, this study compares the behaviors of each technique in presence of solar irradiation variations and temperature fluctuations. These MPPT techniques will be compared using the Matlab / Simulink tool.

14 SOLAR ENERGY↗

Verification of the astrometric performance of the Korean VLBI network, using comparative SFPR studies with the VLBA AT 14/7 mm

The Korean VLBI Network (KVN) is a new millimeter VLBI dedicated array with the capability to simultaneously observe at multiple frequencies, up to 129 GHz. The innovative multi-channel receivers present significant benefits for astrometric measurements in the frequency domain. The aim of this work is to verify the astrometric performance of the KVN using a comparative study with the VLBA, a well-established instrument. For that purpose, we carried out nearly contemporaneous observations with the KVN and the VLBA, at 14/7 mm, in 2013 April. The KVN observations consisted of simultaneous dual frequency observations, while the VLBA used fast frequency switching observations. We used the Source Frequency Phase Referencing technique for the observational and analysis strategy. We find that having simultaneous observations results in superior compensation for all atmospheric terms in the observables, in addition to offering other significant benefits for astrometric analysis. We have compared the KVN astrometry measurements to those from the VLBA. We find that the structure blending effects introduce dominant systematic astrometric shifts, and these need to be taken into account. We have tested multiple analytical routes to characterize the impact of the low-resolution effects for extended sources in the astrometric measurements. The results from the analysis of the KVN and full VLBA data sets agree within 2σ of the thermal error estimate. We interpret the discrepancy as arising from the different resolutions. We find that the KVN provides astrometric results with excellent agreement, within 1σ, when compared to a VLBA configuration that has a similar resolution. Therefore, this comparative study verifies the astrometric performance of the KVN using SFPR at 14/7 mm, and validates the KVN as an astrometric instrument.

79 ASTRONOMY AND ASTROPHYSICS↗

Direction Modulated Brachytherapy for Treatment of Cervical Cancer. II: Comparative Planning Study With Intracavitary and Intracavitary–Interstitial Techniques

Purpose: To perform a comprehensive comparative planning study evaluating the utility of the proposed direction modulated brachytherapy (DMBT) tandem applicator against standard applicators, in the setting of image guided adaptive brachytherapy of cervical cancer. Methods and Materials: A detailed conceptual article was published in 2014. The proposed DMBT tandem applicator has 6 peripheral grooves of 1.3-mm width, along a 5.4-mm-thick nonmagnetic tungsten alloy rod of density 18.0 g/cm{sup 3}, capable of generating directional dose profiles. We performed a comparative planning study with 45 cervical cancer patients enrolled consecutively in the prospective observational EMBRACE study. In all patients, MRI-based planning was performed while utilizing various tandem-ring (27 patients) and tandem-ring-needles (18 patients) applicators, in accordance with the Groupe Européen de Curiethérapie–European Society for Radiotherapy and Oncology recommendations. For unbiased comparisons, all cases were replanned with an in-house–developed inverse optimization code while enforcing a uniform set of constraints that are reflective of the clinical practice. All plans were normalized to the same high-risk clinical target volume D90 values achieved in the original clinical plans. Results: In general, if the standard tandem was replaced with the DMBT tandem while maintaining all other planning conditions the same, there was consistent improvement in the plan quality. For example, among the 18 tandem-ring-needles cases, the average D2cm{sup 3} reductions achieved were −2.48% ± 11.03%, −4.45% ± 5.24%, and −5.66% ± 6.43% for the bladder, rectum, and sigmoid, respectively. An opportunity may also exist in avoiding use of needles altogether for when the total number of needles required is small (approximately 2 to 3 needles or less), if DMBT tandem is used. Conclusions: Integrating the novel DMBT tandem onto both intracavitary and intracavitary–interstitial applicator assembly enabled consistent improvement in the sparing of the OARs, over a standard “single-channel” tandem, though individual variations in benefit were considerable. Although at an early stage of development, the DMBT concept design is demonstrated to be useful and pragmatic for potential clinical translation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Superior liver sparing by combined coplanar/noncoplanar volumetric-modulated arc therapy for hepatocellular carcinoma: A planning and feasibility study

Compared with step-and-shoot intensity-modulated radiotherapy (sIMRT) and tomotherapy, volumetric-modulated arc therapy (VMAT) allows additional arc configurations in treatment planning and noncoplanar (NC) delivery. This study was first to compare VMAT planning with sIMRT planning, and the second to evaluate the toxicity of coplanar (C)/NC-VMAT treatment in patients with hepatocellular carcinoma (HCC). Fifteen patients with HCC (7 with left-lobe and 8 with right-lobe tumors) were planned with C-VMAT, C/NC-VMAT, and sIMRT. The median total dose was 49 Gy (range: 40 to 56 Gy), whereas the median fractional dose was 3.5 Gy (range: 3 to 8 Gy). Different doses/fractionations were converted to normalized doses of 2 Gy per fraction using an α/β ratio of 2.5. The mean liver dose, volume fraction receiving more than 10 Gy (V10), 20 Gy (V20), 30 Gy (V30), effective volume (V{sub eff}), and equivalent uniform dose (EUD) were compared. C/NC-VMAT in 6 patients was evaluated for delivery accuracy and treatment-related toxicity. Compared with sIMRT, both C-VMAT (p = 0.001) and C/NC-VMAT (p = 0.03) had significantly improved target conformity index. Compared with C-VMAT and sIMRT, C/NC-VMAT for treating left-lobe tumors provided significantly better liver sparing as evidenced by differences in mean liver dose (p = 0.03 and p = 0.007), V10 (p = 0.003 and p = 0.009), V20 (p = 0.006 and p = 0.01), V30 (p = 0.02 and p = 0.002), V{sub eff} (p = 0.006 and p = 0.001), and EUD (p = 0.04 and p = 0.003), respectively. For right-lobe tumors, there was no difference in liver sparing between C/NC-VMAT, C-VMAT, and sIMRT. In all patients, dose to more than 95% of target points met the 3%/3 mm criteria. All 6 patients tolerated C/NC-VMAT and none of them had treatment-related ≥ grade 2 toxicity. The C/NC-VMAT can be used clinically for HCC and provides significantly better liver sparing in patients with left-lobe tumors.

61 RADIATION PROTECTION AND DOSIMETRY↗

Comparative Theoretical Study of the Ring-Opening Polymerization of Caprolactam vs Caprolactone Using QM/MM Methods

Candida antarctica lipase B (CALB) efficiently catalyzes the ring-opening polymerization of lactones to high molecular weight products in good yield. In contrast, an efficient enzymatic synthesis of polyamides has so far not been described in the literature. This obvious difference in enzyme catalysis is the subject of our comparative study of the initial steps of a CALB catalyzed ring-opening polymerization of ε- caprolactone and ε-caprolactam. We have applied docking tools to generate the reactant state complex and performed quantum mechanical/molecular mechanical (QM/MM) calculations at the density functional theory (DFT) PBE0 level of theory to simulate the acylation of Ser105 by the lactone and the lactam, respectively, via the corresponding first tetrahedral intermediates. We could identify a decisive difference in the accessibility of the two substrates in the ring-opening to the respective acyl enzyme complex as the attack of ε-caprolactam is hindered because of an energetically disfavored proton transfer during this part of the catalytic reaction while ε-caprolactone is perfectly processed along the widely accepted pathway using the catalytic triade of Ser105, His224, and Asp187. Since the generation of an acylated Ser105 species is the crucial step of the polymerization procedure, our results give an explanation for the unsatisfactory enzymatic polyamide formation and opens up new possibilities for targeted rational catalyst redesign in hope of an experimentally useful CALB catalyzed polyamide synthesis.

Environmental Molecular Sciences Laboratory↗

Current Role of Selective Internal Irradiation With Yttrium-90 Microspheres in the Management of Hepatocellular Carcinoma: A Systematic Review

Purpose: This article reviews the role of selective internal irradiation (SIR) with yttrium-90 ({sup 90}Y) microspheres for hepatocellular carcinoma (HCC). Methods and Materials: Studies were identified by searching Medline and PubMed databases for articles from 1990 to 2009 using the keywords 'selective internal irradiation,' 'hepatocellular carcinoma,' 'therapeutic embolization,' and 'yttrium-90.' Results: {sup 90}Y microspheres are a safe and well-tolerated therapy for unresectable HCC (median survival range, 7 -21.6 months). The evidence was limited to cohort studies and comparative studies with historical control. {sup 90}Y microspheres have been reported to downstage unresectable HCC to allow for salvage treatments with curative intent, act as a bridging therapy before liver transplantation, and treat HCC with curative intent for patients who are not surgical candidates because of comorbidities. Conclusions: {sup 90}Y microsphere is recommended as an option of palliative therapy for large or multifocal HCC without major portal vein invasion or extrahepatic spread. It can also be used for recurrent unresectable HCC, as a bridging therapy before liver transplantation, as a tumor downstaging treatment, and as a curative treatment for patients with associated comorbidities who are not candidates for surgery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Trace element content and magnetic properties of commercial HOPG samples studied by ion beam microscopy and SQUID magnetometry

In this study, the impurity concentration and magnetic response of nine highly oriented pyrolytic graphite (HOPG) samples with different grades and from different providers were determined using ion beam microscopy and SQUID magnetometry. Apart from sideface contaminations in the as-received state, bulk contamination of the samples in most cases consists of disk-shaped micron-sized particles made of Ti and V with an additional Fe contamination around the grain perimeter. The saturation magnetization typically increases with Fe concentration, however, there is no simple correlation between Fe content and magnetic moment. The saturation magnetization of one, respectively six, out of nine samples clearly exceeds the maximum contribution from pure Fe or Fe{sub 3}C. For most samples the temperature dependence of the remanence decreases linearly with T – a dependence found previously for defect-induced magnetism (DIM) in HOPG. We conclude that apart from magnetic impurities, additional contribution to the ferromagnetic magnetization exists in pristine HOPG in agreement with previous studies. A comparative study between the results of ion beam microscopy and the commonly used EDX analysis shows clearly that EDX is not a reliable method for quantitative trace elemental analysis in graphite, clarifying weaknesses and discrepancies in the element concentrations given in the recent literature.

36 MATERIALS SCIENCE↗

Betatron x-ray radiation from laser-plasma accelerators driven by femtosecond and picosecond laser systems

A comparative experimental study of betatron x-ray radiation from laser wakefield acceleration in the blowout and self-modulated regimes is presented. Our experiments use picosecond duration laser pulses up to 150 J (self-modulated regime) and 60 fs duration laser pulses up to 10 J (blowout regime), for plasmas with electronic densities on the order of 10 19 cm –3 . In the self-modulated regime, where betatron radiation has been very little studied compared to the blowout regime, electrons accelerated in the wake of the laser pulse are subject to both the longitudinal plasma and transverse laser electrical fields. As a result, their motion within the wake is relatively complex; consequently, the experimental and theoretical properties of the x-ray source based on self-modulation differ from the blowout regime of laser wakefield acceleration. In our experimental configuration, electrons accelerated up to about 250 MeV and betatron x-ray spectra with critical energies of about 10–20 keV and photon fluxes between 10 8 and 10 10 photons/eV Sr are reported. In conclusion, our experiments open the prospect of using betatron x-ray radiation for applications, and the source is competitive with current x-ray backlighting methods on multi-kilojoule laser systems.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Optimal PV Inverter Control in Distribution Systems via Data-Driven Distributionally Robust Optimization

Distribution systems with high penetration of uncertain solar generation call for advanced control strategies of photovoltaics (PVs) inverters. This paper proposes a data-driven distributionally robust optimization (DDDRO) approach to optimally controlling the PV inverters to improve the system operation performance under solar power uncertainties. In the proposed DDDRO approach, a Wasserstein ball-based method is proposed to construct the distributional ambiguity set to model the uncertainties of PV generation through partial observations of historical data without knowing exact probability distributions. We further reformulate the computationally intractable DDDRO model to a mixed integer second order cone programming (MISOCP) problem. The effectiveness and out-of-sample performance of the proposed approach have been demonstrated on a modified IEEE 33-node system. We conduct a comparative study to compare the proposed method with traditional chance constrained programming (CCP). It shows that the proposed DDDRO approach can provide a less conservative yet robust solution to minimize the worse-case expectation of the total network loss while maintaining nodal voltages in a secure range.

Xue, Yaosuo↗

A comparative reactivity study of 1-alkene fuels from ethylene to 1-heptene

In this work, a comparative reactivity study of 1-alkene fuels from ethylene to 1-heptene has been performed using ignition delay time (IDT) measurements from both a high-pressure shock tube and a rapid compression machine, at an equivalence ratio of 1.0 in ‘air’, at a pressure of 30 atm in the temperature range of 600–1300 K. At low temperatures (< 950 K), the results show that 1-alkenes with longer carbon chains show higher fuel reactivity, with 1-pentene being the first fuel to show negative temperature coefficient (NTC) behavior followed by 1-hexene and 1-heptene. At high temperatures (> 950 K), the experimental results show that all of the fuels except propene show very similar fuel reactivity, with the IDTs of propene being approximately four times longer than for all of the other 1-alkenes. To analyze the experimental results, a chemistry mechanism has been developed using consistent rate constants for these alkenes. At 650 K, flux analyses show that hydroxyl radicals add to the double bond, followed by addition to molecular oxygen producing hydroxy-alkylperoxy radicals, which can proceed via the Waddington mechanism or alternate internal H-atom isomerizations in chain branching similar to those for alkanes. We have found that the major chain propagation reaction pathways that compete with chain branching pathyways mainly produce hydroxyl rather than hydroperoxyl radicals, which explains the less pronounced NTC behavior for larger 1-alkenes compared to their corresponding alkanes. At 1200 K, flux analyses show that the accumulation of hydroperoxyl radicals is important for the auto-ignition of 1-alkenes from propene to 1-heptene. The rate of production of hydroperoxyl radicals for 1-alkenes from 1-butene to 1-heptene is higher than that for propene, which is due to the longer carbon chain facilitating hydroperoxyl radical formation via more efficient reaction pathways. This is the major reason that propene presents lower fuel reactivity than the other 1-alkenes at high temperatures.

1-Alkene↗