Search NASA⌕ Search

SEARCH · Search NASA

Results for “Conditional distributions”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Soil thermal dynamics, snow cover, and frozen depth under five temperature treatments in an ombrotrophic bog: Constrained forecast with data assimilation: Forecast With Data Assimilation

We report that accurate simulation of soil thermal dynamics is essential for realistic prediction of soil biogeochemical responses to climate change. To facilitate ecological forecasting at the Spruce and Peatland Responses Under Climatic and Environmental change site, we incorporated a soil temperature module into a Terrestrial ECOsystem (TECO) model by accounting for surface energy budget, snow dynamics, and heat transfer among soil layers and during freeze-thaw events. We conditioned TECO with detailed soil temperature and snow depth observations through data assimilation before the model was used for forecasting. The constrained model reproduced variations in observed temperature from different soil layers, the magnitude of snow depth, the timing of snowfall and snowmelt, and the range of frozen depth. The conditioned TECO forecasted probabilistic distributions of soil temperature dynamics in six soil layers, snow, and frozen depths under temperature treatments of +0.0, +2.25, +4.5, +6.75, and +9.0°C. Air warming caused stronger elevation in soil temperature during summer than winter due to winter snow and ice. And soil temperature increased more in shallow soil layers in summer in response to air warming. Whole ecosystem warming (peat + air warmings) generally reduced snow and frozen depths. The accuracy of forecasted snow and frozen depths relied on the precision of weather forcing. Uncertainty is smaller for forecasting soil temperature but large for snow and frozen depths. Lastly, timely and effective soil thermal forecast, constrained through data assimilation that combines process-based understanding and detailed observations, provides boundary conditions for better predictions of future biogeochemical cycles.

54 ENVIRONMENTAL SCIENCES↗

The Effect of Bars on the Ionized ISM: Optical Emission Lines from Milky Way Analogs

Gas interior to the bar of the Milky Way has recently been shown to be the closest example of a low-ionization (nuclear) emission region (LI(N)ER) in the universe. To better understand the nature of this gas, a sample of face-on galaxies with integral field spectroscopy is used to study the ionized gas conditions of 240 barred and 250 nonbarred galaxies, focusing on those that are most similar to the Milky Way. Strong optical line emission of [N ii] λ6584, Hα, [O iii] λ5007, and Hβ are used to diagnose the dominant ionization mechanisms of gas across galaxies and the Galaxy via Baldwin-Phillips-Terlevich diagrams. Barred galaxies show a strong suppression of star formation and an increase in composite and LI(N)ER-like spectra in their inner regions when compared with similar nonbarred counterparts. This effect is lessened in galaxies of very low (log 10 (M * /M ⊙ ) ≲ 10.4) or very high (log 10 (M * /M ⊙ ) ≳ 11.1) total stellar mass. Bar masks from Galaxy Zoo:3D show the bar's nonaxisymmetric effect on the ionized gas and help predict the face-on distribution of ionized gas conditions near the bar of the Milky Way.

79 ASTRONOMY AND ASTROPHYSICS↗

System and method for islanding detection and prevention in distributed generation

Various examples are directed to systems and methods for detecting an islanding condition at an inverter configured to couple a distributed generation system to an electrical grid network. A controller may determine a command frequency and a command frequency variation. The controller may determine that the command frequency variation indicates a potential islanding condition and send to the inverter an instruction to disconnect the distributed generation system from the electrical grid network. When the distributed generation system is disconnected from the electrical grid network, the controller may determine whether the grid network is valid.

47 OTHER INSTRUMENTATION↗

Mangrove Carbon Stocks in Pongara National Park, Gabon

Mangroves are recognized for their valued ecosystem services to coastal areas, and the functional linkages between those services and ecosystem carbon stocks have been established. However, spatially explicit inventories are necessary to facilitate management and protection of mangroves, as well as providing a foundation for payment for ecosystem service programs such as REDD+. We conducted an inventory of carbon stocks in mangroves within Pongara National Park (PNP), Gabon using a stratified random sampling design based on forest canopy height derived from TanDEM-X remote sensing data. Ecosystem carbon pools, including aboveground and belowground biomass and necromass, and soil carbon to a depth of 2 m were assessed using measurements and samples from plots distributed among three canopy height classes within the park. There were two mangrove species within the inventory area in PNP, Rhizophora racemosa and R. harrisonii. R. harrisonii was predominant in the sparse, low-stature stands that dominated the west side of the park. In the east side of the park, both species occurred in tall-stature stands, with tree height often exceeding 30 m. Canopy height was an effective means to stratify the inventory area, as biomass was significantly different among the height classes. Despite those differences in aboveground biomass, the soil carbon density was not significantly different among height classes. Soils were the main component of the ecosystem carbon stock, accounting for over 84% of the total. The ecosystem carbon density ranged from 644 to 943 Mg C ha−1 among the three height classes. The ecosystem carbon stock within PNP is estimated to be 40,588 Gg C. The combination of pre-inventory information about stand conditions and their spatial distribution within the assessment area obtained from remote sensing data and a spatial decision support system were fundamental to implementing this relatively large-scale field inventory. This work exemplifies how mangrove carbon stocks can be quantified to augment national C reporting statistics, provide a baseline for projects involving monitoring, reporting and verification (i.e., MRV), and provide data on the forest composition and structure for sustainable management and conservation practices.

Carl C Trettin↗

Voltage positioning using co-optimization of controllable grid assets in radial networks

With increasing penetration of solar PV, some distribution feeders are experiencing highly variable net-load flows and even reverse flows. To optimize distribution systems under such conditions, the scheduling of mechanical devices, such as OLTCs and capacitor banks, needs to take into account forecasted solar PV and actual grid conditions. However, these legacy switching assets are operated on a daily or hourly timescale, due to the wear and tear associated with mechanical switching, which makes them unsuitable for real-time control. Therefore, there is a natural timescale- separation between these slower mechanical assets and the responsive nature of inverter-based resources. In this paper, we present a network admissible convex formulation for holistically scheduling controllable grid assets to position voltage optimally against solar PV. An optimal hourly schedule is presented that utilizes mechanical resources to position the predicted voltages close to nominal values, while minimizing the use of inverter-based resources (i.e., DERs), making them available for control at a faster time-scale (after the uncertainty reveals itself). A convex, inner approximation of the OPF problem is adapted to a mixed-integer linear program that minimizes voltage deviations from nominal (i.e., maximizes voltage margins). Here, the resulting OPF solution respects all the network constraints and is, hence, robust against modeling simplifications. Simulation based analysis on IEEE distribution feeders validates the approach.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Solutal Convection Around Growing Protein Crystal and Diffusional Purification in Space

This work theoretically addressed two subjects: 1) onset of convection, 2) distribution of impurities. Onset of convection was considered analytically and numerically. Crystal growth was characterized by slow surface incorporation kinetics, i.e. growth kinetic coefficient beta (cm/s) small as compared to the typical bulk diffusion rate, D(sub 1)/h, where D(sub 1) is diffusivity of major crystallizing protein and h is the crystal size. Scaling type analysis predicted two laws on how the convection rate, v, essentially the Peclet number, Pe exactly equal to vh/D(sub 1), depends on dimensionless kinetic coefficient a exactly equal to beta h/D(sub 1). Namely: Pe = C(sub 2/5)(aRa(sup 2/5)) and Pe = C(sub 1) aRa. Here, Reynolds number Ra = rho(sub 1)(sup 0)gh(sup 3)(rho(sub p) - rho(sub w))/rho(sup p)rho(sub 1)vD(sub 1), v being solution viscosity. The constants C(sub 2/5), exactly equal to 0.28 and C(sub 1) exactly equal to 10(exp -2) found from the full scale computer simulation for a cylindrical crystal inside big cylindrical vessel. The linear boundary conditions connecting protein and impurity concentration at the interface with the flux to/from the interface was applied. No-slip condition for Navier-Shocker equations was employed. With these conditions, flow and concentration distributions were calculated. Validity of the Pe(Ra) dependencies follows for wide range of parameters for which numerical calculations have been accomplished and presented by various points.

Chernov, A. A.↗

Exploratory Pu(III) Oxalate/Pu(IV) Oxide Morphology Studies

Exploratory experiments were performed to see if morphological information (particle- size/habit) about PuO 2 might give useful information about growth conditions for its oxalate precursor. We performed experiments with trivalent Pu and its analogue, trivalent cerium (Ce). Movies of the Ce oxalate experiments showed that solution turbidities can be a useful monitor for the precipitation kinetics. It was clear that when mixing was too slow to keep up with oxalic acid addition, precipitates formed locally, and partially re-dissolved when oxalic addition was complete. The Ce oxalate and oxide particle-sizes determined in liquid slurries by traditional light-scattering instrumentation agreed in general with those found by SEM imaging. The Ce oxalate size distributions depended on the synthesis conditions, but it was not monotonic in the progression from best- to worst-mixed. Uniformity, as measured by the FWHM (full width at half maximum) of the distributions, varied by a factor of two or more. Because the distributions and FWHMs did not change monotonically as synthesis conditions changed from best- to worst-mixed, the utility of the size distributions for Ce as a diagnostic is doubtful.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Combustion-related pollutants of polydisperse single-composition aerosols and advection fog formation

The most noticeable effect of air pollution on the properties of the atmosphere is the reduction in visibility, with and without the occurrence of condensation, which frequently accompanies polluted air. The present study concerns the formation of advection fog associated with aerosols, due to combustion-related pollutants, with a polydisperse population distribution and a single composition model. The results show that an aerosol population with high particle concentration-shifted distribution provides a more favorable condition for the formation of dense fog than an aerosol population with a low particle concentration-shifted distribution if the value of the mass concentration of the aerosols is kept constant.

Hung, R. J.↗

Measurements of CH4, N2O, CO, H2O, and O3 in the middle atmosphere by the Atmospheric Trace Molecule Spectroscopy Experiment on Spacelab 3

The volume mixing ratios of five minor gases (CH4, N2O, CO, H2O, and O3) have been retrieved through the middle atmosphere from the analysis of 0.01/cm resolution infrared solar occultation spectra recorded near 28 deg N and 48 deg S latitudes with the Atmospheric Trace Molecule Spectroscopy instrument, flow on board Spacelab 3 (April 30 through May 6, 1985). The results are in general agreement with reported measurements from ground-, balloon-, and satellite-based instruments for the same seasons. In detail, the vertical profiles of these gases show the effects of the upper and middle atmospheric transport patterns dominant during the season of these observations. The profiles inferred at different longitudes around 28 deg N suggest a near-uniform zonal distribution of these gases, for conditions corresponding to late spring. The sunrise occultation measurements point to a larger longitudinal variability in the vertical distribution of these gases at 48 deg S.

Gunson, M. R.↗

Numerical modeling of the interstellar medium in galactic disks

We have been developing detailed hydrodynamic models of the global interstellar medium in the hope of understanding the mass and volume occupied by various phases, as well as their structure and kinematics. In our model, the gas is modeled by one fluid while representative Pop 1 stars are modeled by a second fluid. The two fluids are coupled in that the gas forms into stars at a rate given by a Schmidt law while stellar mass loss returns matter into the gas phase (on a time scale of 100 Myr). Also, the stars heat the gas through stellar winds and the gas cools through optically thin radiation. The time behavior of these two fluids is studied in two spatial dimensions with the Eulerian finite difference numerical hydrodynamic code Zen. The two spatial dimensions are along the plane of a disk (x, total length of 2 kpc) and perpendicular to the disk (z, total height of +/- 15 kpc) and a galactic gravitational field in the z direction, typical of that at the solar circle, is imposed upon the simulation; self-gravity and rotation are absent. For the boundary conditions, outflow is permitted at the top and bottom of the grid (z = +/- 15 kpc) while periodic boundary conditions are imposed upon left and right sides of the grid. As initial conditions, we assumed a gaseous distribution like that seen for the H1 by earlier researchers, although the results are insensitive to the initial conditions. We have run simulations in which the heating due to stars, parameterized as a stellar wind velocity, a, is varied from low (a = 150 km/s), to intermediate (a = 300 km/s), to high (a = 600 km/s). Since the intermediate case is roughly equivalent to the Galactic energy injection rate from supernovae, this summary will concentrate on results from this simulation.

Rosen, A.↗

Integrating Indigenous Traditional, Local and Scientific Knowledge for Improved Management, Policy and Decision-Making in Reindeer Husbandry in the Russian Arctic

As scientists and policy-makers from both indigenous and non-indigenous communities begin to build closer partnerships to address common sustainability issues such as the health impacts of climate change and anthropogenic activities, it becomes increasingly important to create shared information management systems which integrate all relevant factors for optimal information sharing and decision-making. This paper describes a new GIs-based system being designed to bring local and indigenous traditional knowledge together with scientific data and information, remote sensing, and information technologies to address health-related environment, weather, climate, pollution and land use change issues for improved decision/policy-making for reindeer husbandry. The system is building an easily-accessible archive of relevant current and historical, traditional, local and remotely-sensed and other data and observations for shared analysis, measuring, and monitoring parameters of interest. Protection of indigenous culturally sensitive information will be respected through appropriate data protocols. A mechanism which enables easy information sharing among all participants, which is real time and geo-referenced and which allows interconnectivity with remote sites is also being designed into the system for maximum communication among partners. A preliminary version of our system will be described for a Russian reindeer test site, which will include a combination of indigenous knowledge about local conditions and issues, remote sensing and ground-based data on such parameters as the vegetation state and distribution, snow cover, temperature, ice condition, and infrastructure.

Maynard, Nancy G.↗

Turbulent Jet Flames Into a Vitiated Coflow

Examined is the vitiated coflow flame, an experimental condition that decouples the combustion processes of flows found in practical combustors from the associated recirculating fluid mechanics. The configuration consists of a 4.57 mm diameter fuel jet into a coaxial flow of hot combustion products from a lean premixed flame. The 210 mm diameter coflow isolates the jet flame from the cool ambient, providing a hot environment similar to the operating conditions of advanced combustors; this important high temperature element is lacking in the traditional laboratory experiments of jet flames into cool (room) air. A family of flows of increasing complexity is presented: 1) nonreacting flow, 2) all hydrogen flame (fuel jet and premixed coflow), and 3) set of methane flames. This sequence of experiments provides a convenient ordering of validation data for combustion models. Laser Raman-Rayleigh-LIF diagnostics at the Turbulent Diffusion Flame laboratory of Sandia National Laboratories produced instantaneous multiscalar point measurements. These results attest to the attractive features of the vitiated coflow burner and the well-defined boundary conditions provided by the coflow. The coflow is uniform and steady, isolating the jet flame from the laboratory air for a downstream distance ranging from z/d = 50-70. The statistical results show that differential diffusion effects in this highly turbulent flow are negligible. Complementing the comprehensive set of multiscalar measurements is a parametric study of lifted methane flames that was conducted to analyze flame sensitivity to jet and coflow velocity, as well as coflow temperature. The linear relationship found between the lift-off height and the jet velocity is consistent with previous experiments. New linear sensitivities were found correlating the lift-off height to coflow velocity and temperature. A blow-off study revealed that the methane flame blows off at a common coflow temperature (1260 K), regardless of coflow or jet velocity. An explanation for this phenomenon is that entrainment of ambient air at the high lift-off heights prevents autoignition. Analysis of the results suggests that flame stabilization occurs through a combination of flame propagation, autoignition, and localized extinction processes. Proposed is an expanded view of distributed reaction combustion based on analysis of the distributions of probe volume conditions at the stabilization region of the lifted hydrogen and methane flames. Turbulent eddies the size of the flame thickness mix fuel and hot coflow across the flame front, thereby enhancing the reaction zone with autoignition of reactants at elevated temperatures; this is the reverse effect of turbulent flames in ambient air, where intense turbulence in cool mixtures result in localized extinction. Each of the three processes (i.e., flame propagation, autoignition and localized extinction) contributes to flame stabilization in varying degrees, depending on flow conditions.

Holdeman, James D.↗

Enhancing Distribution System Resiliency Using Grid-Forming Fuel Cell Inverter: Preprint

Legacy inverters interfacing distributed energy re-sources are traditionally grid-following (GFL) in nature. GFL assets typically follow real power and reactive power set points. Recently, inverters with grid-forming (GFM) capability are gaining attention as GFM assets can increase the resiliency of the distribution system under stressed conditions. These GFM inverters can use photovoltaics, batteries, or fuel cells as their energy source. In this paper, we present information on inverters interfacing fuel cell assets, specifically with GFM capability. By introducing a fuel cell powered GFM coupled with hydrogen production and storage, the GFM can continuously provide GFM activities during periods of low renewable resource availability, and/or during power outages exceeding typical electric battery duration. Finally, we present information on the need for updates on interconnection and interoperability standards that can be leveraged by utilities for including fuel cell inverters in their asset mix.

fuel cell inverters↗

VERA neutronics high-fidelity benchmark for a modern PWR core design

Nearly 20 years since the origin of the infamous 'Kord Smith Challenge', and after 10 years and hundreds of millions of dollars invested by the US Department of Energy into the development of the Virtual Environment for Reactor Applications (VERA), the capability to accurately simulate a modern pressurized water reactor (PWR) fuel cycle at the fuel rod level with high-fidelity Monte Carlo (MC) stochastic transport methods still evades us. The deterministic methods in VERA make approximations that allow it to be successfully benchmarked against measured data from hundreds of PWR fuel cycles, but none of these benchmarks provided information at the local fuel rod level or allowed quantification of these approximations' impact for modern PWR reload designs. Using MPACT to establish the estimated isotopic distributions and thermal hydraulic conditions in a recent and challenging reactor design, a 2D quarter-core benchmark problem was established and solved consistently with both MPACT, the 51-energy group deterministic transport solver in VERA, and Shift, the continuous-energy MC transport solver in VERA. Impacts of energy groups, ray spacing, and scattering treatment were evaluated. Though MPACT has been previously shown to perform well compared to MC methods for initial Cycle 1 cores with only fresh fuel, this is the first benchmark of MPACT for a challenging modern reload core with depleted fuel and burnable absorbers. This work establishes additional credibility for the methods in MPACT and highlights the efficiency of these methods relative to those in use by MC-based tools. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Building America Case Study: Standard- Versus High-Velocity Air Distribution in High-Performance Townhomes, Denver, Colorado

IBACOS investigated the performance of a small-diameter high velocity heat pump system compared to a conventional system in a new construction triplex townhouse. A ductless heat pump system also was installed for comparison, but the homebuyer backed out because of aesthetic concerns about that system. In total, two buildings, having identical solar orientation and comprised of six townhomes, were monitored for comfort and energy performance. Results show that the small-diameter system provides more uniform temperatures from floor to floor in the three-story townhome. No clear energy consumption benefit was observed from either system. The builder is continuing to explore the small-diameter system as its new standard system to provide better comfort and indoor air quality. The homebuilder also explored the possibility of shifting its townhome product to meet the U.S. Department of Energy Challenge Home National Program Requirements. Ultimately, the builder decided that adoption of these practices would be too disruptive midstream in the construction cycle. However, the townhomes met the ENERGY STAR Version 3.0 program requirements.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Polarimetric Retrievals of Surface and Cirrus Clouds Properties in the Region Affected by the Deepwater Horizon Oil Spill

In 2010, the Goddard Institute for Space Studies (GISS) Research Scanning Polarimeter (RSP) performed several aerial surveys over the region affected by the oil spill caused by the explosion of the Deepwater Horizon offshore platform. The instrument was deployed on the NASA Langley B200 aircraft together with the High Spectral Resolution Lidar (HSRL), which provides information on the distribution of the aerosol layers beneath the aircraft, including an accurate estimate of aerosol optical depth. This work illustrates the merits of polarization measurements in detecting variations of ocean surface properties linked to the presence of an oil slick. In particular, we make use of the degree of linear polarization in the glint region, which is severely affected by variations in the refractive index but insensitive to the waviness of the water surface. Alterations in the surface optical properties are therefore expected to directly affect the polarization response of the RSP channel at 2264 nm, where both molecular and aerosol scattering are negligible and virtually all of the observed signal is generated via Fresnel reflection at the surface. The glint profile at this wavelength is fitted with a model which can optimally estimate refractive index, wind speed and direction, together with aircraft attitude variations affecting the viewing geometry. The retrieved refractive index markedly increases over oil-contaminated waters, while the apparent wind speed is significantly lower than in adjacent uncontaminated areas, suggesting that the slick dampens high-frequency components of the ocean wave spectrum. The constraint on surface reflectance provided by the short-wave infrared channels is a cornerstone of established procedures to retrieve atmospheric aerosol microphysical parameters based on the inversion of the RSP multispectral measurements. This retrieval, which benefits from the ancillary information provided by the HSRL, was in this specific case hampered by prohibitive variability in atmospheric conditions (very inhomogeneous aerosol distribution and cloud cover). Although the results presented for the surface are essentially unaffected, we discuss the results obtained by typing algorithms in sorting the complex mix of aerosol types, and show evidence of oriented ice in cirrus clouds present in the area. In this context, polarization measurements at 1880 nm were used to infer ice habit and cirrus optical depth, which was found in the subvisual/threshold-visible regime, confirming the utility of the aforementioned RSP channel for the remote sensing of even thin cold clouds.

Polarization↗

Emergency Voltage Regulation in Power Systems via Ripple-Type Control

With increasing penetrations of volatile renewable generation and cyber-physical disruptions, ensuring the safe operation of bulk power systems has become unprecedentedly challenging. Because communication and computational costs restrict centralized system dispatch to being called upon every few minutes, and because purely local schemes are shown to be insufficient, distributed controls have been advocated for handling unanticipated system conditions in real time. The applicability of distributed control schemes, however, is fundamentally limited by their need for widespread communication and model cognizance. In this context, we put forth a hybrid, low-communication, saturation-driven protocol for the coordination of control agents that are distributed over a physical system and are allowed to communicate with peers over a "hotline" communication network. Under this protocol, when agents observe a constraint violation based on local measurements, they respond locally until their control resources saturate, in which case they send a beacon for assistance to peer agents. The scheme ensures that minor violations are efficiently mitigated via fast local controls, whereas severe violations can be handled by collaboration among a relatively small set of agents. We evaluate the performance of this scheme via numerical tests on the IEEE 14-bus test feeder, where agents act upon noisy measurements under diverse scenarios of load variations and severe low-/high-voltage events.

collaboration↗

Evidence for Spiral Magnetic Structures at the Magnetopause: A Case for Multiple Reconnections

We analyze plasma structures within the low latitude boundary layer (LLBL) observed by the lnterball Tail spacecraft under southward interplanetary magnetic field. Ion velocity distributions observed in the LLBL under these conditions fall into three categories: (a) D-shaped distributions, (b) ion velocity distributions consisting of two counterstreaming magnetosheath-type, and (c) distributions with three components where one of them has nearly zero velocity parallel to magnetic field (VlI), while the other two are counter-streaming components. D-shaped ion velocity distributions (a) correspond to magnetosheath plasma injections into reconnected flux tubes, as influenced by spacecraft location relative to the reconnection site. Simultaneous counter-streaming injections (b) suggest multiple reconnections. Three-component ion velocity distributions (c) and theii evolution with decreasing number density in the LLBL are consistent v behavior expected on long spiral flux tube islands at the magnetopaus as has been proposed and found to occur in magnetopause simulatior We interpret these distributions as a natural consequence of the formation of spiral magnetic flux tubes consisting of a mixture of alternating segments originating from the magnetosheath and magnetospheric plasmas. We suggest that multiple reconnections pla! an important role in the formation of the LLBL.

Vaisberg, O. L.↗