Search NASA⌕ Search

SEARCH · Search NASA

Results for “Control Practices”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Investigation of Radiological Contamination at Parks in the Gateway National Recreation Area - 20350

In 2005, the National Park Service was notified that elevated radiation levels were detected at Great Kills Park during a baseline radiological mapping effort conducted by the Counter Terrorism Bureau of the New York City Police Department and the United States Department of Energy. Great Kills Park is in the Staten Island Unit of the Gateway National Recreation Area. A records search determined that approximately 280 acres of the park was established over an area in which the New York City Department of Sanitation placed approximately 15.1 million cubic yards of waste fill from 1944 to 1948. Since 2005, a series of response actions and investigations were conducted on behalf of the National Park Service to mitigate risk to human health and the environment and to determine the nature of radiological contamination at Great Kills Park. The findings support that radiological contamination is related to certain components of waste fill, including incinerator residue from both on and offsite incinerators, coal ash from the historical use of coal-fired boilers for heating, and incidental radiological artifacts in the waste fill due to their historical use and subsequent disposal. A majority of the radiological artifacts were determined to contain radium-226 and included radioluminescent markers, radium impregnated switch board buttons, radium paint containers, and brachytherapy devices. The National Park Service has several other Parks in the Gateway National Recreation Area that were established in areas with a similar history to Great Kills Park, and overlie waste fill historically placed during landfilling operations, including Spring Creek Park and Dead Horse Bay. Over the last year, the National Park Service has performed additional radiological investigations at Great Kills Park as part of the ongoing Remedial Investigation under the Comprehensive Environmental Response, Compensation, and Liability Act. In addition, preliminary radiological investigations were performed at Spring Creek Park and Dead Horse Bay Park in the Jamaica Bay Unit of Gateway National Recreation Area. These investigation activities identified gamma radiation levels above the ambient level, several of which were attributable to radiological artifacts similar in nature to those recovered at Great Kills Park. Ongoing investigations at Parks in the Gateway National Recreation Area support an association between radiological contamination and historical landfilling practices that were common prior to the regulation and control of radioactive materials. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

The x-ray light valve: A potentially low-cost, digital radiographic imaging system-concept and implementation considerations

New x-ray radiographic systems based on large-area flat-panel technology have revolutionized our capability to produce digital x-ray images. However, these imagers are extraordinarily expensive compared to the systems they are replacing. Hence, there is a need for a low-cost digital imaging system for general applications in radiology. A novel potentially low-cost radiographic imaging system based on established technologies is proposed--the X-Ray Light Valve (XLV). This is a potentially high-quality digital x-ray detector made of a photoconducting layer and a liquid-crystal cell, physically coupled in a sandwich structure. Upon exposure to x rays, charge is collected on the surface of the photoconductor. This causes a change in the optical properties of the liquid-crystal cell and a visible image is generated. Subsequently, it is digitized by a scanned optical imager. The image formation is based on controlled modulation of light from an external source. The operation and practical implementation of the XLV system are described. The potential performance of the complete system and issues related to sensitivity, spatial resolution, noise, and speed are discussed. The feasibility of clinical use of an XLV device based on amorphous selenium (a-Se) as the photoconductor and a reflective electrically controlled birefringence cell is analyzed. The results of our analysis indicate that the XLV can potentially be adapted to a wide variety of radiographic tasks.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Multidimensional Holistic Framework for the Security of Distributed Energy and Control Systems

The digitization of smart grid distributed generation and industrial control systems has prompted utilities to deploy tools with ubiquitous communications that potentially widen the attack surface. The utilities still continue to rely on the traditional cybersecurity technologies, such as firewalls, anti-malware tools, and passwords that do not ensure security across all dimensions of the information assurance model required for a strong cybersecurity business process. This paper proposes a multidimensional holistic framework that addresses this gap through advanced technologies, intelligent algorithms, and continued assessments. To show proof, the layered defense model, a solution dimension of the framework, is integrated into the National Renewable Energy Laboratory's Security and Resilience Testbed to replicate a utility's enterprise and substation networks. The model is used to evaluate the security and resilience of microgrid control systems, and, based on the insights gathered, recommend best practices for utility cybersecurity analysts for a strong business process. Here, with this baseline, the paper conceptually introduces intelligence-driven solutions comprising contextual data analysis and machine learning to respond to advanced persistent threats sponsored by campaign efforts.

24 POWER TRANSMISSION AND DISTRIBUTION↗

A comparison of efficiency-aware model-predictive control approaches for wave energy devices

In this study, we compare four different formulations of model predictive control that attempt to maximise electrical power generated by a wave energy converter (WEC). Control laws include (1) pure maximisation of mechanical power, (2) maximisation of mechanical power with a control penalty factor, (3) maximisation of electrical power using power conversion efficiency, and (4) maximisation of electrical power using the full electro-mechanical model of a system. For this study, a wave-to-wire model is developed for a floating spherical buoy connected to a permanent magnet synchronous generator. The performance of the controllers, including the mechanical and electrical power outputs, is compared in irregular wave conditions for the unconstrained and force-constrained scenarios. The results demonstrate that the controller designed to maximise mechanical power is not suitable for practical applications and may lead to negative electrical power output due to the non-ideal power take-off efficiency. Moreover, the replacement of the power take-off dynamics by the efficiency coefficient does not guarantee the maximum electrical power production.

16 TIDAL AND WAVE POWER↗

Human-system Interface Style Guide for ACORN Control System

The purpose of this style guide is to provide a clear, consistent framework for the design and development of human system interfaces (HSIs) used throughout the Fermilab accelerator complex. It establishes a shared visual and interaction foundation to ensure that interfaces remain intuitive, effective, and cohesive, regardless of when or by whom they are developed. By adhering to these guidelines, developers can avoid introducing unnecessary deviations that compromise usability or increase system training burden. This consistency is especially critical in long-term, multi-contributor projects where interface continuity and maintainability are paramount. This document serves as a practical reference for all HSI development activities related to the accelerator control environment. While the guidance provided is comprehensive, it is not exhaustive of every potential design scenario. As such, the style guide is intended to function as a living document, subject to regular review and revision. Updates will be made at least annually to incorporate emerging best practices, operational feedback, and evolving system needs. Areas where detailed guidance is still under development are clearly indicated in gray throughout the document and will be addressed in future revisions according to project priorities.

Hill, Rachael [Idaho Natl. Lab.] (ORCID:0000000263↗

Weak anti-localization of two-dimensional holes in germanium beyond the diffusive regime

Gate-controllable spin-orbit coupling is often one requisite for spintronic devices. For practical spin field-effect transistors, another essential requirement is ballistic spin transport, where the spin precession length is shorter than the mean free path such that the gate-controlled spin precession is not randomized by disorder. In this letter, we report the observation of a gate-induced crossover from weak localization to weak anti-localization in the magneto-resistance of a high-mobility twodimensional hole gas in a strained germanium quantum well. From the magneto-resistance, we extract the phase-coherence time, spin-orbit precession time, spin-orbit energy splitting, and cubic Rashba coefficient over a wide density range. The mobility and the mean free path increase with increasing hole density, while the spin precession length decreases due to increasingly stronger spin-orbit coupling. As the density becomes larger than , 6 x 10 11 cm -2 , the spin precession length becomes shorter than the mean free path, and the system enters the ballistic spin transport regime. We also report here the numerical methods and code developed for calculating the magnetoresistance in the ballistic regime, where the commonly used HLN and ILP models for analyzing weak localization and anti-localization are not valid. These results pave the way toward siliconcompatible spintronic devices.

42 ENGINEERING↗

Dielectric metasurfaces for complete control of phase and polarization with subwavelength spatial resolution and high transmission

Metasurfaces are planar structures that locally modify the polarization, phase and amplitude of light in reflection or transmission, thus enabling lithographically patterned flat optical components with functionalities controlled by design1,2. Transmissive metasurfaces are especially important, as most optical systems used in practice operate in transmission. Several types of transmissive metasurface have been realized3,4,5,6, but with either low transmission efficiencies or limited control over polarization and phase. Here, we show a metasurface platform based on high-contrast dielectric elliptical nanoposts that provides complete control of polarization and phase with subwavelength spatial resolution and an experimentally measured efficiency ranging from 72% to 97%, depending on the exact design. Such complete control enables the realization of most free-space transmissive optical elements such as lenses, phase plates, wave plates, polarizers, beamsplitters, as well as polarization-switchable phase holograms and arbitrary vector beam generators using the same metamaterial platform.

36 MATERIALS SCIENCE↗

AVESTAR Center for Operational Excellence of Electricity Generation Plants

To address industry challenges in attaining operational excellence for electricity generation plants, the U.S. Department of Energy’s (DOE) National Energy Technology Laboratory (NETL) has launched a world-class facility for Advanced Virtual Energy Simulation Training and Research (AVESTARTM). This presentation will highlight the AVESTARTM Center simulators, facilities, and comprehensive training, education, and research programs focused on the operation and control of high-efficiency, near-zero-emission electricity generation plants. The AVESTAR Center brings together state-of-the-art, real-time, high-fidelity dynamic simulators with full-scope operator training systems (OTSs) and 3D virtual immersive training systems (ITSs) into an integrated energy plant and control room environment. AVESTAR’s initial offering combines--for the first time--a “gasification with CO2 capture” process simulator with a “combined-cycle” power simulator together in a single OTS/ITS solution for an integrated gasification combined cycle (IGCC) power plant with carbon dioxide (CO2) capture. IGCC systems are an attractive technology option for power generation, especially when capturing and storing CO2 is necessary to satisfy emission targets. The AVESTAR training program offers a variety of courses that merge classroom learning, simulator-based OTS learning in a control-room operations environment, and immersive learning in the interactive 3D virtual plant environment or ITS. All of the courses introduce trainees to base-load plant operation, control, startups, and shutdowns. Advanced courses require participants to become familiar with coordinated control, fuel switching, power-demand load shedding, and load following, as well as to problem solve equipment and process malfunctions. Designed to ensure work force development, training is offered for control room and plant field operators, as well as engineers and managers. Such comprehensive simulator-based instruction allows for realistic training without compromising worker, equipment, and environmental safety. It also better prepares operators and engineers to manage the plant closer to economic constraints while minimizing or avoiding the impact of any potentially harmful, wasteful, or inefficient events. The AVESTAR Center is also used to augment graduate and undergraduate engineering education in the areas of process simulation, dynamics, control, and safety. Students and researchers gain hands-on simulator-based training experience and learn how the commercial-scale power plants respond dynamically to changes in manipulated inputs, such as coal feed flow rate and power demand. Students also analyze how the regulatory control system impacts power plant performance and stability. In addition, students practice start-up, shutdown, and malfunction scenarios. The 3D virtual ITSs are used for plant familiarization, walk-through, equipment animations, and safety scenarios. To further leverage the AVESTAR facilities and simulators, NETL and its university partners are pursuing an innovative and collaborative R&D program. In the area of process control, AVESTAR researchers are developing enhanced strategies for regulatory control and coordinated plant-wide control, including gasifier and gas turbine lead, as well as advanced process control using model predictive control (MPC) techniques. Other AVESTAR R&D focus areas include high-fidelity equipment modeling using partial differential equations, dynamic reduced order modeling, optimal sensor placement, 3D virtual plant simulation, and modern grid. NETL and its partners plan to continue building the AVESTAR portfolio of dynamic simulators, immersive training systems, and advanced research capabilities to satisfy industry’s growing need for training and experience with the operation and control of clean energy plants. Future dynamic simulators under development include natural gas combined cycle (NGCC) and supercritical pulverized coal (SCPC) plants with post-combustion CO2 capture. These dynamic simulators are targeted for use in establishing a Virtual Carbon Capture Center (VCCC), similar in concept to the DOE’s National Carbon Capture Center for slipstream testing. The VCCC will enable developers of CO2 capture technologies to integrate, test, and optimize the operation of their dynamic capture models within the context of baseline power plant dynamic models. The objective is to provide hands-on, simulator-based “learn-by-operating” test platforms to accelerate the scale-up and deployment of CO2 capture technologies. Future AVESTAR plans also include pursuing R&D on the dynamics, operation, and control of integrated electricity generation and storage systems for the modern grid era. Special emphasis will be given to combining load-following energy plants with renewable and distributed generating supplies and fast-ramping energy storage systems to provide near constant baseload power.

97 MATHEMATICS AND COMPUTING↗

Temporal nitrogen dynamics in intensively managed loblolly pine early stand development

Forest production is strongly dependent on nutrient uptake; however, sustainable management of intensively managed plantations requires an improved understanding of this relationship when fertilization occurs frequently across short rotations. Here, we studied temporal nitrogen (N) concentration ([N]) and content (Nc) dynamics under different silvicultural practices (herbicide, fertilization, and planting density) throughout early loblolly pine (Pinus taeda) stand development (5 years). We describe relationships of [N] and Nc of different stand components (foliage, branches, stem, roots, and competing vegetation) with carbon and biomass. Our results demonstrate that [N] of perennial loblolly tissues do not respond to silvicultural practices and progressively decrease through development. While foliar [N] was most responsive to resource availability, it was not consistent across time. Controlling competing vegetation was crucial to promote the use of site resources by the crop tree and increased loblolly Nc by >500%. However, increased N uptake and expedited growth is dependent upon fertilization early in stand development. At age 5, herbicide plus reduced and full fertilization rates exhibited similar aboveground Nc, which was 32% higher than with herbicide only. Increasing planting density resulted in increased above- and belowground loblolly Nc; however, increases in Nc were not proportional with increases in planting density. Net primary productivity and N uptake were linearly related, but age/development strongly controlled N use efficiency. Our study helps to understand complex relationships between N, biomass, and silvicultural practices during early stand development and demonstrates that temporal evaluation of nutrient dynamics is crucial to better understand loblolly pine growth, carbon sequestration potential, and to inform sustainable silvicultural practices across short rotations.

54 ENVIRONMENTAL SCIENCES↗

Distillation Column Flooding Predictor

The Flooding Predictor™ is a patented advanced control technology proven in research at the Separations Research Program, University of Texas at Austin, to increase distillation column throughput by over 6%, while also increasing energy efficiency by 10%. The research was conducted under a U. S. Department of Energy Cooperative Agreement awarded to George Dzyacky of 2ndpoint, LLC. The Flooding Predictor™ works by detecting the incipient flood point and controlling the column closer to its actual hydraulic limit than historical practices have allowed. Further, the technology uses existing column instrumentation, meaning no additional refining infrastructure is required. Refiners often push distillation columns to maximize throughput, improve separation, or simply to achieve day-to-day optimization. Attempting to achieve such operating objectives is a tricky undertaking that can result in flooding. Operators and advanced control strategies alike rely on the conventional use of delta-pressure instrumentation to approximate the column’s approach to flood. But column delta-pressure is more an inference of the column’s approach to flood than it is an actual measurement of it. As a consequence, delta pressure limits are established conservatively in order to operate in a regime where the column is never expected to flood. As a result, there is much “left on the table” when operating in such a regime, i.e. the capacity difference between controlling the column to an upper delta-pressure limit and controlling it to the actual hydraulic limit. The Flooding Predictor™, an innovative pattern recognition technology, controls columns at their actual hydraulic limit, which research shows leads to a throughput increase of over 6%. Controlling closer to the hydraulic limit also permits operation in a sweet spot of increased energy-efficiency. In this region of increased column loading, the Flooding Predictor is able to exploit the benefits of higher liquid/vapor traffic that produce increased contact area and lead to substantial increases in separation efficiency – which translates to a 10% increase in energy efficiency on a BTU/bbl basis. The Flooding Predictor™ operates on the principle that between five to sixty minutes in advance of a flooding event, certain column variables experience an oscillation, a pre-flood pattern. The pattern recognition system of the Flooding Predictor™ utilizes the mathematical first derivative of certain column variables to identify the column’s pre-flood pattern(s). This pattern is a very brief, highly repeatable, simultaneous movement among the derivative values of certain column variables. While all column variables experience negligible random noise generated from the natural frequency of the process, subtle pre-flood patterns are revealed among sub-sets of the derivative values of column variables as the column approaches its hydraulic limit. The sub-set of column variables that comprise the pre-flood pattern is identified empirically through in a two-step process. First, 2ndpoint’s proprietary off-line analysis tool is used to mine historical data for pre-flood patterns. Second, the column is flood-tested to fine-tune the pattern recognition for commissioning. Then the Flooding Predictor™ is implemented as closed-loop advanced control strategy on the plant’s distributed control system (DCS), thus automating control of the column at its hydraulic limit.

02 PETROLEUM↗

Multienergy CT acquisition and reconstruction with a stepped tube potential scan

Purpose: Based on an energy-dependent property of matter, one may obtain a pseudomonochromatic attenuation map, a material composition image, an electron-density distribution, and an atomic number image using a dual- or multienergy computed tomography (CT) scan. Dual- and multienergy CT scans broaden the potential of x-ray CT imaging. The development of such systems is very useful in both medical and industrial investigations. In this paper, the authors propose a new dual- and multienergy CT system design (segmental multienergy CT, SegMECT) using an innovative scanning scheme that is conveniently implemented on a conventional single-energy CT system. The two-step-energy dual-energy CT can be regarded as a special case of SegMECT. A special reconstruction method is proposed to support SegMECT. Methods: In their SegMECT, a circular trajectory in a CT scan is angularly divided into several arcs. The x-ray source is set to a different tube voltage for each arc of the trajectory. Thus, the authors only need to make a few step changes to the x-ray energy during the scan to complete a multienergy data acquisition. With such a data set, the image reconstruction might suffer from severe limited-angle artifacts if using conventional reconstruction methods. To solve the problem, they present a new prior-image-based reconstruction technique using a total variance norm of a quotient image constraint. On the one hand, the prior extracts structural information from all of the projection data. On the other hand, the effect from a possibly imprecise intensity level of the prior can be mitigated by minimizing the total variance of a quotient image. Results: The authors present a new scheme for a SegMECT configuration and establish a reconstruction method for such a system. Both numerical simulation and a practical phantom experiment are conducted to validate the proposed reconstruction method and the effectiveness of the system design. The results demonstrate that the proposed SegMECT can provide both attenuation images and material decomposition images of reasonable image quality. Compared to existing methods, the new system configuration demonstrates advantages in simplicity of implementation, system cost, and dose control. Conclusions: This proposed SegMECT imaging approach has great potential for practical applications. It can be readily realized on a conventional CT system.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Impact of Active Control on Passive Safety Response Characteristics of Sodium-cooled Fast Reactors: I - Theoretical background

Here, the interaction of the active control system with passive safety behavior is investigated for sodium-cooled fast reactors. A claim often made of advanced reactors is that they are passively safe against unprotected upset events. In practice, such upset events are not analyzed in the context of the plant control system, but rather the analyses are performed without considering the normally programmed response of the control system (open-loop approach). This represents an oversimplification of the safety case. The issue of passive safety override arises since the control system commands actuators whose motions have safety consequences. Depending on the upset involving the control system ( operator error, active control system failure, or inadvertent control system override), an actuator does not necessarily go in the same direction as needed for safety. So neglecting to account for control system action during an unprotected upset is nonconservative from a safety standpoint. It is important then, during the design of the plant, to consider the potential for the control system to work against the inherent and safe regulating effects of purposefully engineered temperature feedbacks.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Covariance-Free Bifidelity Control Variates Importance Sampling for Rare Event Reliability Analysis

Multifidelity modeling has been steadily gaining attention as a tool to address the problem of exorbitant model evaluation costs that makes the estimation of failure probabilities a significant computational challenge for complex real-world problems, particularly when failure is a rare event. To implement multifidelity modeling, estimators that efficiently combine information from multiple models/sources are necessary. In past works, the variance reduction techniques of control variates (CV) and importance sampling (IS) have been leveraged for this task. In this paper, we present the CVIS framework—a creative take on a coupled CV and IS estimator for bifidelity reliability analysis. The framework addresses some of the practical challenges of the CV method by using an estimator for the control variate mean and sidestepping the need to estimate the covariance between the original estimator and the control variate through a clever choice for the tuning constant. Furthermore, the task of selecting an efficient IS distribution is also considered, with a view towards maximally leveraging the bifidelity structure and maintaining expressivity. Additionally, a diagnostic is provided that indicates both the efficiency of the algorithm as well as the relative predictive quality of the models utilized. Finally, the behavior and performance of the framework is explored through analytical and numerical examples.

Markov chain Monte Carlo↗

Verification and Validation of Digitally Upgraded Control Rooms

As nuclear power plants undertake main control room modernization, a challenge is the lack of a clearly defined human factors process to follow. Verification and validation (V&V) as applied in the nuclear power community has tended to involve efforts such as integrated system validation, which comes at the tail end of the design stage. To fill in guidance gaps and create a step-by-step process for control room modernization, we have developed the Guideline for Operational Nuclear Usability and Knowledge Elicitation (GONUKE). This approach builds on best practices in the software industry, which prescribe an iterative user-centered approach featuring multiple cycles of design and evaluation. Nuclear regulatory guidance for control room design emphasizes summative evaluation—which occurs after the design is complete. In the GONUKE approach, evaluation is also performed at the formative stage of design—early in the design cycle using mockups and prototypes for evaluation. The evaluation may involve expert review (e.g., software heuristic evaluation at the formative stage and design verification against human factors standards like NUREG-0700 at the summative stage). The evaluation may also involve user testing (e.g., usability testing at the formative stage and integrated system validation at the summative stage). An additional, often overlooked component of evaluation is knowledge elicitation, which captures operator insights into the system. In this report we outline these evaluation types across design phases that support the overall modernization process. The objective is to provide industry-suitable guidance for steps to be taken in support of the design and evaluation of a new human-machine interface (HMI) in the control room. We suggest the value of early-stage V&V and highlight how this early-stage V&V can help improve the design process for control room modernization. We argue that there is a need to overcome two shortcomings of V&V in current practice—the propensity for late-stage V&V and the use of increasingly complex psychological assessment measures for V&V.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Learning Constrained Parametric Differentiable Predictive Control Policies With Guarantees

We present differentiable predictive control (DPC), a method for offline learning of constrained neural control policies for nonlinear dynamical systems with performance guarantees. We show that the sensitivities of the parametric optimal control problem can be used to obtain direct policy gradients. Specifically, we employ automatic differentiation (AD) to efficiently compute the sensitivities of the model predictive control (MPC) objective function and constraints penalties. To guarantee safety upon deployment, we derive probabilistic guarantees on closed-loop stability and constraint satisfaction based on indicator functions and Hoeffding’s inequality. We empirically demonstrate that the proposed method can learn neural control policies for various parametric optimal control tasks. In particular, we show that the proposed DPC method can stabilize systems with unstable dynamics, track time-varying references, and satisfy nonlinear state and input constraints. Our DPC method has practical time savings compared to alternative approaches for fast and memory-efficient controller design. Specifically, DPC does not depend on a supervisory controller as opposed to approximate MPC based on imitation learning. We demonstrate that, without losing performance, DPC is scalable with greatly reduced demands on memory and computation compared to implicit and explicit MPC while being more sample efficient than model-free reinforcement learning (RL) algorithms.

97 MATHEMATICS AND COMPUTING↗

Continuous Under-Frequency Load Shedding Scheme for Power System Adaptive Frequency Control

Frequency drop due to loss of massive generation is a threat to power system frequency stability. Under-frequency load shedding (UFLS) is the principal measure to prevent successive frequency declination and blackouts. Based on traditional stage-by-stage UFLS scheme, a new continuous UFLS scheme is proposed in this paper to shed loads proportional to frequency deviation. The characteristic of the proposed scheme is analyzed with a closed-form solution of frequency dynamics. Frequency threshold and time delay are added to make the proposed scheme practical. A line-by-line scheme based on precise load control is introduced to implement the continuous scheme for systems without enough continuously controllable loads. The load shedding scale factor of the proposed scheme is tuned with an analytical method to achieve adaptability to different operating conditions. Furthermore, the adaptability of the proposed scheme is validated with 39-bus New England model and simplified Shandong Power Grid of China.

42 ENGINEERING↗

Floodplain statement of findings for corrective actions in Potrillo Canyon technical area-36, Los Alamos National Laboratory, Los Alamos, New Mexico

In 2014, baseline storm water monitoring samples for Potrillo Canyon Sample Management Area at Los Alamos National Laboratory (LANL) exceeded the National Pollutant Discharge Elimination System Individual Permit No. NM0030759 target action level (TAL) of 15 picocuries per liter (pCi/L) for gross-alpha radioactivity (393 pCi/L) and a TAL of 30 pCi/L for radium-226 and radium-228 (95.9 pCi/L). Consequently, erosion control measures within the management area are proposed to minimize sediment migration, a corrective action under the permit that is a requirement of the New Mexico Environment Department consent decree and a good management practice to limit off-site sediment migration. The area proposed for erosion controls consists of portions of Technical Area 36 that were used as firing sites primarily involving high explosives (HE) and metal (e.g., depleted uranium, lead, copper, aluminum, and steel), small-explosives experiments and burn pits (burn pits were used for burning and disposal of test debris). In addition, underground explosive tests at an approximate depth of 100 feet were also conducted. These watershed-based storm water controls will focus on addressing erosion occurring within the floodplain through mitigating and reducing both current and future channelization and head cutting.

54 ENVIRONMENTAL SCIENCES↗

Development of a plant-wide dynamic model of an integrated gasification combined cycle (IGCC) plant

In this presentation, development of a plant-wide dynamic model of an advanced Integrated Gasification Combined Cycle (IGCC) plant with CO2 capture will be discussed. The IGCC reference plant generates 640 MWe of net power using Illinois No.6 coal as the feed. The plant includes an entrained, downflow, General Electric Energy (GEE) gasifier with a radiant syngas cooler (RSC), a two-stage water gas shift (WGS) conversion process, and two advanced 'F' class combustion turbines partially integrated with an elevated-pressure air separation unit (ASU). A subcritical steam cycle is considered for heat recovery steam generation. Syngas is selectively cleaned by a SELEXOL acid gas removal (AGR) process. Sulfur is recovered using a two-train Claus unit with tail gas recycle to the AGR. A multistage intercooled compressor is used for compressing CO2 to the pressure required for sequestration. Using Illinois No.6 coal, the reference plant generates 640 MWe of net power. The plant-wide steady-state and dynamic IGCC simulations have been generated using the Aspen Plus{reg_sign} and Aspen Plus Dynamics{reg_sign} process simulators, respectively. The model is generated based on the Case 2 IGCC configuration detailed in the study available in the NETL website1. The GEE gasifier is represented with a restricted equilibrium reactor model where the temperature approach to equilibrium for individual reactions can be modified based on the experimental data. In this radiant-only configuration, the syngas from the Radiant Syngas Cooler (RSC) is quenched in a scrubber. The blackwater from the scrubber bottom is further cleaned in the blackwater treatment plant. The cleaned water is returned back to the scrubber and also used for slurry preparation. The acid gas from the sour water stripper (SWS) is sent to the Claus plant. The syngas from the scrubber passes through a sour shift process. The WGS reactors are modeled as adiabatic plug flow reactors with rigorous kinetics based on the mid-life activity of the shift-catalyst. The SELEXOL unit consists of the H2S and CO2 absorbers that are designed to meet the stringent environmental limits and requirements of other associated units. The model also considers the stripper for recovering H2S that is sent as a feed to a split-flow Claus unit. The tail gas from the Claus unit is recycled to the SELEXOL unit. The cleaned syngas is sent to the GE 7FB gas turbine. This turbine is modeled as per published data in the literature. Diluent N2 is used from the elevated-pressure ASU for reducing the NOx formation. The heat recovery steam generator (HRSG) is modeled by considering generation of high-pressure, intermediate-pressure, and low-pressure steam. All of the vessels, reactors, heat exchangers, and the columns have been sized. The basic IGCC process control structure has been synthesized by standard guidelines and existing practices. The steady-state simulation is solved in sequential-modular mode in Aspen Plus{reg_sign} and consists of more than 300 unit operations, 33 design specs, and 16 calculator blocks. The equation-oriented dynamic simulation consists of more than 100,000 equations solved using a multi-step Gear's integrator in Aspen Plus Dynamics{reg_sign}. The challenges faced in solving the dynamic model and key transient results from this dynamic model will also be discussed.

97 MATHEMATICS AND COMPUTING↗