Search NASA⌕ Search

SEARCH · Search NASA

Results for “Control Room”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

WE-H-207B-03: MRI Guidance in the Radiation Therapy Clinic: Site-Specific Discussions

In recent years, steady progress has been made towards the implementation of MRI in external beam radiation therapy for processes ranging from treatment simulation to in-room guidance. Novel procedures relying mostly on MR data are currently implemented in the clinic. This session will cover topics such as (a) commissioning and quality control of the MR in-room imagers and simulators specific to RT, (b) treatment planning requirements, constraints and challenges when dealing with various MR data, (c) quantification of organ motion with an emphasis on treatment delivery guidance, and (d) MR-driven strategies for adaptive RT workflows. The content of the session was chosen to address both educational and practical key aspects of MR guidance. Learning Objectives: Good understanding of MR testing recommended for in-room MR imaging as well as image data validation for RT chain (e.g. image transfer, filtering for consistency, spatial accuracy, manipulation for task specific); Familiarity with MR-based planning procedures: motivation, core workflow requirements, current status, challenges; Overview of the current methods for the quantification of organ motion; Discussion on approaches for adaptive treatment planning and delivery. T. Stanescu - License agreement with Modus Medical Devices to develop a phantom for the quantification of MR image system-related distortions.; T. Stanescu, N/A.

60 APPLIED LIFE SCIENCES↗

WE-H-207B-04: Strategies for Adaptive RT

In recent years, steady progress has been made towards the implementation of MRI in external beam radiation therapy for processes ranging from treatment simulation to in-room guidance. Novel procedures relying mostly on MR data are currently implemented in the clinic. This session will cover topics such as (a) commissioning and quality control of the MR in-room imagers and simulators specific to RT, (b) treatment planning requirements, constraints and challenges when dealing with various MR data, (c) quantification of organ motion with an emphasis on treatment delivery guidance, and (d) MR-driven strategies for adaptive RT workflows. The content of the session was chosen to address both educational and practical key aspects of MR guidance. Learning Objectives: Good understanding of MR testing recommended for in-room MR imaging as well as image data validation for RT chain (e.g. image transfer, filtering for consistency, spatial accuracy, manipulation for task specific); Familiarity with MR-based planning procedures: motivation, core workflow requirements, current status, challenges; Overview of the current methods for the quantification of organ motion; Discussion on approaches for adaptive treatment planning and delivery. T. Stanescu - License agreement with Modus Medical Devices to develop a phantom for the quantification of MR image system-related distortions.; T. Stanescu, N/A.

60 APPLIED LIFE SCIENCES↗

WE-H-207B-01: Commissioning and QC

In recent years, steady progress has been made towards the implementation of MRI in external beam radiation therapy for processes ranging from treatment simulation to in-room guidance. Novel procedures relying mostly on MR data are currently implemented in the clinic. This session will cover topics such as (a) commissioning and quality control of the MR in-room imagers and simulators specific to RT, (b) treatment planning requirements, constraints and challenges when dealing with various MR data, (c) quantification of organ motion with an emphasis on treatment delivery guidance, and (d) MR-driven strategies for adaptive RT workflows. The content of the session was chosen to address both educational and practical key aspects of MR guidance. Learning Objectives: Good understanding of MR testing recommended for in-room MR imaging as well as image data validation for RT chain (e.g. image transfer, filtering for consistency, spatial accuracy, manipulation for task specific); Familiarity with MR-based planning procedures: motivation, core workflow requirements, current status, challenges; Overview of the current methods for the quantification of organ motion; Discussion on approaches for adaptive treatment planning and delivery. T. Stanescu - License agreement with Modus Medical Devices to develop a phantom for the quantification of MR image system-related distortions.; T. Stanescu, N/A.

60 APPLIED LIFE SCIENCES↗

Doppler Velocimetry of Current Driven Spin Helices in a Two-Dimensional Electron Gas

Spins in semiconductors provide a pathway towards the development of spin-based electronics. The appeal of spin logic devices lies in the fact that the spin current is even under time reversal symmetry, yielding non-dissipative coupling to the electric field. To exploit the energy-saving potential of spin current it is essential to be able to control it. While recent demonstrations of electrical-gate control in spin-transistor configurations show great promise, operation at room temperature remains elusive. Further progress requires a deeper understanding of the propagation of spin polarization, particularly in the high mobility semiconductors used for devices. This dissertation presents the demonstration and application of a powerful new optical technique, Doppler spin velocimetry, for probing the motion of spin polarization at the level of 1 nm on a picosecond time scale. We discuss experiments in which this technique is used to measure the motion of spin helices in high mobility n-GaAs quantum wells as a function of temperature, in-plane electric field, and photoinduced spin polarization amplitude. We find that the spin helix velocity changes sign as a function of wave vector and is zero at the wave vector that yields the largest spin lifetime. This observation is quite striking, but can be explained by the random walk model that we have developed. We discover that coherent spin precession within a propagating spin density wave is lost at temperatures near 150 K. This finding is critical to understanding why room temperature operation of devices based on electrical gate control of spin current has so far remained elusive. We report that, at all temperatures, electron spin polarization co-propagates with the high-mobility electron sea, even when this requires an unusual form of separation of spin density from photoinjected electron density. Furthermore, although the spin packet co-propagates with the two-dimensional electron gas, spin diffusion is strongly suppressed by electron-electron interactions, leading to remarkable resistance to diffusive spreading of the drifting pulse of spin polarization. Finally, we show that spin helices continue propagate at the same speed as the Fermi sea even when the electron drift velocity exceeds the Fermi velocity of 107 cm s -1 .

36 MATERIALS SCIENCE↗

Energy Savings for Occupancy-Based Control (OBC) of Variable-Air-Volume (VAV) Systems

Terminal boxes usually serve a single building zone, controlling the air-flow rate to the zone and reheating the air when it is too cool. Each terminal box has a minimum air-flow rate that ensures the ventilation requirements of the occupants of the zone served are met. This minimum air-flow rate is maintained at a constant value based on the design occupancy of the zone, which often corresponds to the maximum occupancy, because measurements of actual occupancy are not currently used to adjust the flow rate. Therefore, the minimum flow rate must meet the ventilation needs of the fully occupied zone. The total flow rate may be higher than the minimum to provide adequate cooling or heating, but the minimum for ventilation should always be met. In practice, control system integrators and installers often set the cooling minimum air-flow rate for ventilation to between 30% and 50% of the maximum air-flow rate of the terminal box. Building occupancy, however, varies dynamically. Conference rooms, cafeterias, auditoriums, and other assembly spaces are often unoccupied for significant periods of time. Office occupancy varies during the course of a work day, from day to day, and over the longer term because of attendance of meetings elsewhere, business travel, changing room functions, and variations in staffing. The resulting over-ventilation, during times when the space has less than maximum occupancy or is unoccupied, wastes significant fan energy and causes discomfort for occupants in some spaces (e.g., conference rooms) from overcooling or overheating, especially in interior zones that do not have reheat in the terminal boxes. Common occupancy sensors, which measure whether occupants are present or not, are commonly used for lighting control in conference rooms and other spaces with variable occupancy. They could be used to enable a terminal box to be switched to an occupied standby mode in which the air-flow rate is set to zero when no occupants are in the zone the box serves. If advanced occupancy sensors, which count the actual number of occupants in a room, were used to control terminal boxes, the minimum air-flow rate set point for the terminal box could be reset dynamically based on the actual occupancy sensed. This study evaluates the savings potential from use of occupancy-based control (OBC) of terminal boxes for large office buildings with variable-air-volume (VAV) heating, ventilating and air-conditioning (HVAC) systems using both common occupancy sensors and advanced occupancy sensors.

Zhang, Jian↗

Length scale selects directionality of droplets on vibrating pillar ratchet

Directional control of droplet motion at room temperature is of interest for applications such as microfluidic devices, self-cleaning coatings, and directional adhesives. Here, arrays of tilted pillars ranging in height from the nanoscale to the microscale are used as structural ratchets to directionally transport water at room temperature. Water droplets deposited on vibrating chips with a nanostructured ratchet move preferentially in the direction of the feature tilt while the opposite directionality is observed in the case of microstructured ratchets. This remarkable switch in directionality is consistent with changes in the contact angle hysteresis. To glean further insights into the length scale dependent asymmetric contact angle hysteresis, the contact lines formed by a nonvolatile room temperature ionic liquid placed onto the tilted pillar arrays were visualized and analyzed in situ in a scanning electron microscope. As a result, the ability to tune droplet directionality by merely changing the length scale of surface features all etched at the same tilt angle would be a versatile tool for manipulating multiphase flows and for selecting droplet directionality in other lap-on-chip applications.

42 ENGINEERING↗

Rapid sonochemical preparation of shape-selective lead iodide

Graphical abstract: SEM morphologies of various PbI2 products obtained with the iodine concentration of 6.7 g/L and irradiation time of 1 minute at the reaction temperatures of 35 °C (a), 25 °C (b), and 15 °C (c). Highlights: ► PbI{sub 2} with various morphologies were rapidly formed at room temperature. ► We could well control the morphologies of PbI{sub 2} by changing reaction conditions. ► The PbI{sub 2} films could better resist rolling in a liquid media. -- Abstract: Lead iodide (PbI{sub 2}) films/crystals with various nano/micro morphologies (e.g., Nanoflake, block and microrod) were rapidly synthesized by taking advantage of a simple sonochemical method. The PbI{sub 2} crystals with uniform nanoflake structures could be fabricated directly on lead foils with the irradiation time as short as 36 s via interfacial reaction between lead foils and elemental iodine in ethanol at ambient temperature. It was found experimentally that the morphologies of the resulting thin films/crystals could be well controlled by the adjustment of several parameters including irradiation time, reaction solvents, iodine concentration, ultrasonic power, and reaction temperature. Most importantly, the resultant PbI{sub 2} films are stable enough to resist rolling under the drastic ultrasound irradiation in a liquid media. This method is believed to be the fastest way for in situ fabrication of morphology-controlled semiconductor films on various metal substrates for subsequent applications related to the other metal iodide or metal sulfide semiconductor films.

36 MATERIALS SCIENCE↗

Method for Controlling Temperature Profiles and Water Table Depths in Laboratory Sediment Columns

Core Ideas Column experiments simulating subsurface environments require control of temperature profiles. A 2‐m‐tall laboratory sediment column reproduced vadose zone thermal and hydraulic conditions. Measured CO 2 profiles show the importance of microbial respiration below the root zone. Transport from the soil surface to groundwater is commonly mediated through deeper portions of the vadose zone and capillary fringe, where variations in temperature and water saturation strongly influence biogeochemical processes. This technical note describes a sediment column design that allows laboratory simulation of thermal and hydrologic conditions found in many field settings. Temperature control is particularly important because room temperature is not representative of most subsurface environments. A 2.0‐m‐tall column was capable of simulating profiles with temperatures ranging from 3 to 22°C, encompassing the full range of seasonal temperature variation observed in the deep vadose zone and capillary fringe of a semiarid floodplain in western Colorado. The water table was varied within the lower 0.8‐m section of the column, and profiles of water content and matric potential were measured. Vadose zone CO 2 collected from depth‐distributed gas samplers under representative seasonal conditions reflected the influences of temperature and water table depth on microbial respiration. Thus, realistic subsurface biogeochemical dynamics can be simulated in the laboratory through establishing column profiles that represent seasonal thermal and hydrologic conditions.

54 ENVIRONMENTAL SCIENCES↗

Demonstration of Data Center Energy Use Prediction Software

This report documents a demonstration of a software modeling tool from Romonet that was used to predict energy use and forecast energy use improvements in an operating data center. The demonstration was conducted in a conventional data center with a 15,500 square foot raised floor and an IT equipment load of 332 kilowatts. It was cooled using traditional computer room air handlers and a compressor-based chilled water system. The data center also utilized an uninterruptible power supply system for power conditioning and backup. Electrical energy monitoring was available at a number of locations within the data center. The software modeling tool predicted the energy use of the data center's cooling and electrical power distribution systems, as well as electrical energy use and heat removal for the site. The actual energy used by the computer equipment was recorded from power distribution devices located at each computer equipment row. The model simulated the total energy use in the data center and supporting infrastructure and predicted energy use at energy-consuming points throughout the power distribution system. The initial predicted power levels were compared to actual meter readings and were found to be within approximately 10 percent at a particular measurement point, resulting in a site overall variance of 4.7 percent. Some variances were investigated, and more accurate information was entered into the model. In this case the overall variance was reduced to approximately 1.2 percent. The model was then used to predict energy use for various modification opportunities to the data center in successive iterations. These included increasing the IT equipment load, adding computer room air handler fan speed controls, and adding a water-side economizer. The demonstration showed that the software can be used to simulate data center energy use and create a model that is useful for investigating energy efficiency design changes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Safety Tests on Irradiated AGR-1 Compacts 3-3-2, 3-2-2, and 6-2-1

Post-irradiation examination (PIE) is in progress on coated particle fuel compacts from the first Advanced Gas Reactor irradiation experiment (AGR-1). The AGR-1 Post-Irradiation Examination Plan, INL/PLN- 2828/Rev. 1, includes safety testing of the irradiated compacts in the Oak Ridge National Laboratory (ORNL) Core Conduction Cooldown Test Facility (CCCTF) facility and the Idaho National Laboratory Fuel Accident Condition Simulator (FACS) to evaluate the effect of elevated temperature on the fuel microstructure and fission product retention. Safety tests will involve heating compacts for 100– 500 hours to maximum temperatures of 1600°C–1800°C, where 1600°C is the expected maximum temperature during a high-temperature gas-cooled reactor depressurization conduction cooldown event, and 1800°C is the expected temperature at which the performance of the SiC layer will begin to degrade. ORNL completed the first AGR-1 post-irradiation compact safety test in FY2011. During the first two quarters of FY2012, three additional safety tests were completed. Each of these three compacts was heated up to a maximum temperature of 1600°C and held at this temperature for a period of 300 hours. The standard heating profile specified in each compact examination plan called for a controlled ramp of the furnace to 1600°C with soaks at 400 and 1250°C, a hold at 1600°C for 300 hours, and then a controlled ramp back down to room temperature. The CCCTF performed as designed, except for a few interruptions while the furnace was being ramped up to 1600°C. These interruptions were caused by several power supply problems and one mechanical problem with the cold finger. The root causes of these issues have been identified and addressed to ensure better reliability for future CCCTF operation.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Development of 3-cell Traveling Wave SRF Cavity

Traveling wave SRF cavity is a new technology and requires a multi-stage process for development. Conceptual designs have been proposed to adopt TW resonance in an SRF cavity The early stages of developments have been funded by several SBIR grants to Euclid Techlabs which were completed in collaboration with Fermilab. A 3-cell proof-of-principle TW cavity was fabricated as part of that and demonstrated the TW resonance excitation at room temperature. A TW resonance control tuner for the 3-cell was also fabricated and the preliminary tests were performed. Now, the 3-cell cavity is being processed and prepared for the first cryogenic testing.

43 PARTICLE ACCELERATORS↗

Shell-Based Support Structures for Nb3Sn Accelerator Quadrupole Magnets

Shell-based support structures are being fabricated and tested as part of the development of large-aperture Nb{sub 3}Sn superconducting quadrupoles for future upgrades of the LHC Interaction Regions. These structures utilize water pressurized bladders for room-temperature pre-load control, and rely on a pre-tensioned aluminum shell to deliver a substantial part of the coil pre-stress during cool-down. The coil final pre-load is therefore monotonically approached from below, without overstressing the strain-sensitive conductor. This method has been adopted by the US LARP collaboration to test subscale racetrack coils (SQ series), 1 m long cos-theta coils (TQS series), and 4 m long magnets (LRS and LQS series). We present recent progress in the development of shell-based support structures, with a description of the principles of operations and the future plans.

43 PARTICLE ACCELERATORS↗

ELECTRONICS UPGRADE TO THE SAVANNAH RIVER NATIONAL LABORATORY COULOMETER FOR PLUTONIUM AND NEPTUNIUM ASSAY

The Savannah River Site (SRS) has the analytical measurement capability to perform high-precision plutonium concentration measurements by controlled-potential coulometry. State-of-the-art controlled-potential coulometers were designed and fabricated by the Savannah River National Laboratory and installed in the Analytical Laboratories process control laboratory. The Analytical Laboratories uses coulometry for routine accountability measurements of and for verification of standard preparations used to calibrate other plutonium measurement systems routinely applied to process control, nuclear safety, and other accountability applications. The SRNL Coulometer has a demonstrated measurement reliability of {approx}0.05% for 10 mg samples. The system has also been applied to the characterization of neptunium standard solutions with a comparable reliability. The SRNL coulometer features: a patented current integration system; continuous electrical calibration versus Faraday's Constants and Ohm's Law; the control-potential adjustment technique for enhanced application of the Nernst Equation; a wide operating room temperature range; and a fully automated instrument control and data acquisition capability. Systems have been supplied to the International Atomic Energy Agency (IAEA), Russia, Japanese Atomic Energy Agency (JAEA) and the New Brunswick Laboratory (NBL). The most recent vintage of electronics was based on early 1990's integrated circuits. Many of the components are no longer available. At the request of the IAEA and the Department of State, SRNL has completed an electronics upgrade of their controlled-potential coulometer design. Three systems have built with the new design, one for the IAEA which was installed at SAL in May 2011, one system for Los Alamos National Laboratory, (LANL) and one for the SRS Analytical Laboratory. The LANL and SRS systems are undergoing startup testing with installation scheduled for this summer.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Magneto-optical controlled transmittance alteration of PbS quantum dots by moderately applied magnetic fields at room temperature

We observed changes of the transmitted monochromatic light passing through a colloidal PbS quantum dot film on glass owing to an applied moderate (smaller than 1 T) magnetic field under ambient conditions. The observed alterations show a square dependence on the magnetic field increase that cannot be achieved with bulk semiconductors. The findings point to so far not recognized application potentials of quantum dots.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Room temperature persisting surface charge carriers driven by intense terahertz electric fields in a topological insulator Bi 2 Se 3

Topologically protected surface current is highly promising for next-generation low-dissipation and disorder-tolerant quantum electronics and computing. Yet, electric transport from the co-existing bulk state dominates the responses of the Dirac surface state, especially at elevated temperatures relevant to technological applications. Here, we present an approach that convincingly showcases the generation, disentanglement, and precise control of enduring surface charge carriers on a topological insulator, Bi 2 Se 3 , with high bulk conductivity, all achieved at room temperature. By using pump–probe modulation spectroscopy under ultrabroadband driving tunable from 4 meV to 1.55 eV, we show the terahertz (THz) field-induced surface carriers by discovering their initial temporal responses dominant over high density trivial bulk carriers. Strikingly, the response of the induced surface carrier responses persists for more than ~5 ps and is enhanced by reducing pump photon energy. The dynamics and lifetime of the distinct surface response manifest themselves as the enhanced THz pump-induced THz transmission, which directly correlates with the transient negative THz conductivity. Increasing the THz driving field reduces the induced surface carrier lifetime and identifies, particularly, an optimal pump field of E s ~ 224 kV cm -1 for generating the dominant surface response relative to the bulk. This surface carrier dominant regime is suppressed by a joint effect of enhanced surface-bulk scattering and a more rapid saturation of surface excitation compared to the bulk that sets in above E s . The controllability of room temperature topologically surface carriers through pump photon energy offer compelling possibilities for extending this approach to other topological complex materials.

36 MATERIALS SCIENCE↗

Measurement and control system for cryogenic helium gas bearing turbo-expander experimental platform based on Siemens PLC S7-300

An experimental platform for cryogenic Helium gas bearing turbo-expanders is established at the Technical Institute of Physics and Chemistry, Chinese Academy of Sciences. This turbo-expander experimental platform is designed for performance testing and experimental research on Helium turbo-expanders with different sizes from the liquid hydrogen temperature to the room temperature region. A measurement and control system based on Siemens PLC S7-300 for this turbo-expander experimental platform is developed. Proper sensors are selected to measure such parameters as temperature, pressure, rotation speed and air flow rate. All the collected data to be processed are transformed and transmitted to S7-300 CPU. Siemens S7-300 series PLC CPU315-2PN/DP is as master station and two sets of ET200M DP remote expand I/O is as slave station. Profibus-DP field communication is established between master station and slave stations. The upper computer Human Machine Interface (HMI) is compiled using Siemens configuration software WinCC V6.2. The upper computer communicates with PLC by means of industrial Ethernet. Centralized monitoring and distributed control is achieved. Experimental results show that this measurement and control system has fulfilled the test requirement for the turbo-expander experimental platform.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Indirect excitons in van der Waals heterostructures at room temperature

Indirect excitons (IXs) are explored both for studying quantum Bose gases in semiconductor materials and for the development of excitonic devices. IXs were extensively studied in III–V and II–VI semiconductor heterostructures where IX range of existence has been limited to low temperatures. Here, we present the observation of IXs at room temperature in van der Waals transition metal dichalcogenide (TMD) heterostructures. Here, this is achieved in TMD heterostructures based on monolayers of MoS2 separated by atomically thin hexagonal boron nitride. The IXs we realize in the TMD heterostructure have lifetimes orders of magnitude longer than lifetimes of direct excitons in single-layer TMD and their energy is gate controlled. The realization of IXs at room temperature establishes the TMD heterostructures as a material platform both for a field of high-temperature quantum Bose gases of IXs and for a field of high-temperature excitonic devices.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Wide-range continuous tuning of the thermal conductivity of La0.5Sr0.5CoO3-δ films via room-temperature ion-gel gating

Abstract Solid-state control of the thermal conductivity of materials is of exceptional interest for novel devices such as thermal diodes and switches. Here, we demonstrate the ability to continuously tune the thermal conductivity of nanoscale films of La 0.5 Sr 0.5 CoO 3- δ (LSCO) by a factor of over 5, via a room-temperature electrolyte-gate-induced non-volatile topotactic phase transformation from perovskite (with δ ≈ 0.1) to an oxygen-vacancy-ordered brownmillerite phase (with δ = 0.5), accompanied by a metal-insulator transition. Combining time-domain thermoreflectance and electronic transport measurements, model analyses based on molecular dynamics and Boltzmann transport equation, and structural characterization by X-ray diffraction, we uncover and deconvolve the effects of these transitions on heat carriers, including electrons and lattice vibrations. The wide-range continuous tunability of LSCO thermal conductivity enabled by low-voltage (below 4 V) room-temperature electrolyte gating opens the door to non-volatile dynamic control of thermal transport in perovskite-based functional materials, for thermal regulation and management in device applications.

42 ENGINEERING↗