Search NASA⌕ Search

SEARCH · Search NASA

Results for “Counting statistics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

The Chandra Deep Wide-field Survey: A New Chandra Legacy Survey in the Bootes Field. I. X-ray Point Source Catalog, Number Counts, and Multiwavelength Counterparts

We present a new, ambitious survey performed with the Chandra X-ray Observatory of the 9.3 deg2 Boötes field of the NOAO Deep Wide-Field Survey. The wide field probes a statistically representative volume of the universe at high redshift. The Chandra Deep Wide-field Survey exploits the excellent sensitivity and angular resolution of Chandra over a wide area, combining 281 observations spanning 15 yr, for a total exposure time of 3.4 Ms, and detects 6891 X-ray point sources down to limiting fluxes of 4.7 × 10−16, 1.5 × 10−16, and 9 × 10−16 erg cm−2 s−1 in the 0.5–7, 0.5–2, and 2–7 keV bands, respectively. The robustness and reliability of the detection strategy are validated through extensive, state-of-the-art simulations of the whole field. Accurate number counts, in good agreement with previous X-ray surveys, are derived thanks to the uniquely large number of point sources detected, which resolve 65.0% ± 12.8% of the cosmic X-ray background between 0.5 and 2 keV and 81.0% ± 11.5% between 2 and 7 keV. Exploiting the wealth of multiwavelength data available on the field, we assign redshifts to ∼94% of the X-ray sources, estimate their obscuration, and derive absorption-corrected luminosities. We provide an electronic catalog containing all of the relevant quantities needed for future investigations.

Catalogs↗

Evaluation of sliding baseline methods for spatial estimation for cluster detection in the biosurveillance system

Background: The Centers for Disease Control and Prevention's (CDC's) BioSense system provides near-real time situational awareness for public health monitoring through analysis of electronic health data. Determination of anomalous spatial and temporal disease clusters is a crucial part of the daily disease monitoring task. Our study focused on finding useful anomalies at manageable alert rates according to available BioSense data history. Methods: The study dataset included more than 3 years of daily counts of military outpatient clinic visits for respiratory and rash syndrome groupings. We applied four spatial estimation methods in implementations of space-time scan statistics cross-checked in Matlab and C. We compared the utility of these methods according to the resultant background cluster rate (a false alarm surrogate) and sensitivity to injected cluster signals. The comparison runs used a spatial resolution based on the facility zip code in the patient record and a finer resolution based on the residence zip code. Results: Simple estimation methods that account for day-of-week (DOW) data patterns yielded a clear advantage both in background cluster rate and in signal sensitivity. A 28-day baseline gave the most robust results for this estimation; the preferred baseline is long enough to remove daily fluctuations but short enough to reflect recent disease trends and data representation. Background cluster rates were lower for the rash syndrome counts than for the respiratory counts, likely because of seasonality and the large scale of the respiratory counts. Conclusion: The spatial estimation method should be chosen according to characteristics of the selected data streams. In this dataset with strong day-of-week effects, the overall best detection performance was achieved using subregion averages over a 28-day baseline stratified by weekday or weekend/holiday behavior. Changing the estimation method for particular scenarios involving different spatial resolution or other syndromes can yield further improvement.

59 BASIC BIOLOGICAL SCIENCES↗

Improving Weak Lensing Mass Map Reconstructions using Gaussian and Sparsity Priors: Application to DES SV

Mapping the underlying density field, including non-visible dark matter, using weak gravitational lensing measurements is now a standard tool in cosmology. Due to its importance to the science results of current and upcoming surveys, the quality of the convergence reconstruction methods should be well understood. We compare three methods: Kaiser–Squires (KS), Wiener filter, and Glimpse. Kaiser–Squires is a direct inversion, not accounting for survey masks or noise. The Wiener filter is well-motivated for Gaussian density fields in a Bayesian framework. Glimpse uses sparsity, aiming to reconstruct non-linearities in the density field. We compare these methods with several tests using public Dark Energy Survey (DES) Science Verification (SV) data and realistic DES simulations. The Wiener filter and Glimpse offer substantial improvements over smoothed Kaiser–Squires with a range of metrics. Both the Wiener filter and Glimpse convergence reconstructions show a 12 per cent improvement in Pearson correlation with the underlying truth from simulations. To compare the mapping methods’ abilities to find mass peaks, we measure the difference between peak counts from simulated ΛCDM shear catalogues and catalogues with no mass fluctuations (a standard data vector when inferring cosmology from peak statistics); the maximum signal-to-noise of these peak statistics is increased by a factor of 3.5 for the Wiener filter and 9 for Glimpse. With simulations, we measure the reconstruction of the harmonic phases; the phase residuals’ concentration is improved 17 per cent by Glimpse and 18 per cent by the Wiener filter. The correlationbetween reconstructions from data and foreground redMaPPer clusters is increased 18 per cent by the Wiener filter and 32 per cent by Glimpse.

79 ASTRONOMY AND ASTROPHYSICS↗

Global Frequency and Distribution of Lightning as Observed from Space by the Optical Transient Detector

The Optical Transient Detector (OTD) is a space-based instrument specifically designed to detect and locate lightning discharges as it orbits the Earth. This instrument is a scientific payload on the MicroLab-1 satellite that was launched into a low-earth, 70 deg. inclination orbit in April 1995. Given the orbital trajectory of the satellite, most regions of the earth are observed by the OTD instrument more than 400 times during a one year period, and the average duration of each observation is 2 minutes. The OTD instrument optically detects lightning flashes that occur within its 1300x1300 sq km field-of-view during both day and night conditions. A statistical examination of OTD lightning data reveals that nearly 1.4 billion flashes occur annually over the entire earth. This annual flash count translates to an average of 44 +/- 5 lightning flashes (intracloud and cloud-to-ground combined) occurring around the globe every second, which is well below the traditional estimate of 100 flashes per second that was derived in 1925 from world thunder-day records. The range of uncertainty for the OTD global totals represents primarily the uncertainty (and variability) in the flash detection efficiency of the instrument. The OTD measurements have been used to construct lightning climatology maps that demonstrate the geographical and seasonal distribution of lightning activity for the globe. An analysis of this annual lightning distribution confirms that lightning occurs mainly over land areas, with an average land:ocean ratio of 10:1. A dominant Northern Hemisphere summer peak occurs in the annual cycle, and evidence is found for a tropically-driven semiannual cycle.

Christian, Hugh J.↗

Cation dopant distributions in nanostructures of transition-metal doped ZnO:Monte Carlo simulations

The path from trace doping to solid solution formation involves an intermediate regime in which the doping level is a few to several atomic percent. In this regime, dopant-dopant interactions, which are driven by the spatial arrangement of dopants, are critical factors in determining the resulting properties. Conventional wisdom counts on simple probabilistic methods for predicting dopant distributions. Here, we use Monte Carlo simulations to show that widely used, straightforward statistical models, such as that of Behringer1, are accurate only in the limit of infinitesimally small surface–to-volume ratio. For epitaxial films and nanoparticles, where much of the current interest resides, dopant distributions depend strongly on the surface-to-volume ratio. We present empirical expressions that accurately predict dopant bonding configurations as a function of film or particle size, shape and dopant concentration for doped ZnO, a material of particular interest in semiconductor spintronics.

36 MATERIALS SCIENCE↗

Simulation Model of Mobile Detection Systems

In this paper, we consider a mobile source that we attempt to detect with man-portable, vehicle-mounted or boat-mounted radiation detectors. The source is assumed to transit an area populated with these mobile detectors, and the objective is to detect the source before it reaches a perimeter. We describe a simulation model developed to estimate the probability that one of the mobile detectors will come in to close proximity of the moving source and detect it. We illustrate with a maritime simulation example. Our simulation takes place in a 10 km by 5 km rectangular bay patrolled by boats equipped with 2-inch x 4-inch x 16-inch NaI detectors. Boats to be inspected enter the bay and randomly proceed to one of seven harbors on the shore. A source-bearing boat enters the mouth of the bay and proceeds to a pier on the opposite side. We wish to determine the probability that the source is detected and its range from target when detected. Patrol boats select the nearest in-bound boat for inspection and initiate an intercept course. Once within an operational range for the detection system, a detection algorithm is started. If the patrol boat confirms the source is not present, it selects the next nearest boat for inspection. Each run of the simulation ends either when a patrol successfully detects a source or when the source reaches its target. Several statistical detection algorithms have been implemented in the simulation model. First, a simple k-sigma algorithm, which alarms with the counts in a time window exceeds the mean background plus k times the standard deviation of background, is available to the user. The time window used is optimized with respect to the signal-to-background ratio for that range and relative speed. Second, a sequential probability ratio test [Wald 1947] is available, and configured in this simulation with a target false positive probability of 0.001 and false negative probability of 0.1. This test is utilized when the mobile detector maintains a constant range to the vessel being inspected. Finally, a variation of the sequential probability ratio test that is more appropriate when source and detector are not at constant range is available [Nelson 2005]. Each patrol boat in the fleet can be assigned a particular zone of the bay, or all boats can be assigned to monitor the entire bay. Boats assigned to a zone will only intercept and inspect other boats when they enter their zone. In our example simulation, each of two patrol boats operate in a 5 km by 5 km zone. Other parameters for this example include: (1) Detection range - 15 m range maintained between patrol boat and inspected boat; (2) Inbound boat arrival rate - Poisson process with mean arrival rate of 30 boats per hour; (3) Speed of boats to be inspected - Random between 4.5 and 9 knots; (4) Patrol boat speed - 10 knots; (5) Number of detectors per patrol boat - 4-2-inch x 4-inch x 16-inch NaI detectors; (6) Background radiation - 40 counts/sec per detector; and (7) Detector response due to radiation source at 1 meter - 1,589 counts/sec per detector. Simulation results indicate that two patrol boats are able to detect the source 81% of the time without zones and 90% of the time with zones. The average distances between the source and target at the end of the simulation is 5,866 km and 5,712 km for non-zoned and zoned patrols, respectively. Of those that did not reach the target, the average distance to the target is 7,305 km and 6,441 km respectively. Note that a design trade-off exists. While zoned patrols provide a higher probability of detection, the nonzoned patrols tend to detect the source farther from its target. Figure 1 displays the location of the source at the end of 1,000 simulations for the 5 x 10 km bay simulation. The simulation model and analysis described here can be used to determine the number of mobile detectors one would need to deploy in order to have a have reasonable chance of detecting a source in transit. By fixing the source speed to zero, the same model could be used to estimate how long it would take to detect a stationary source. For example, the model could predict how long it would take plant staff performing assigned duties carrying dosimeters to discover a contaminated spot in the facility.

61 RADIATION PROTECTION AND DOSIMETRY↗

Landing Site Dispersion Analysis and Statistical Assessment for the Mars Phoenix Lander

The Mars Phoenix Lander launched on August 4, 2007 and successfully landed on Mars 10 months later on May 25, 2008. Landing ellipse predicts and hazard maps were key in selecting safe surface targets for Phoenix. Hazard maps were based on terrain slopes, geomorphology maps and automated rock counts of MRO's High Resolution Imaging Science Experiment (HiRISE) images. The expected landing dispersion which led to the selection of Phoenix's surface target is discussed as well as the actual landing dispersion predicts determined during operations in the weeks, days, and hours before landing. A statistical assessment of these dispersions is performed, comparing the actual landing-safety probabilities to criteria levied by the project. Also discussed are applications for this statistical analysis which were used by the Phoenix project. These include using the statistical analysis used to verify the effectiveness of a pre-planned maneuver menu and calculating the probability of future maneuvers.

Bonfiglio, Eugene P.↗

A Statistical Test of Uniformity in Solar Cycle Indices

Several indices are used to characterize the solar activity cycle. Key among these are: the International Sunspot Number, the Group Sunspot Number, Sunspot Area, and 10.7 cm Radio Flux. A valuable aspect of these indices is the length of the record -- many decades and many (different) 11-year cycles. However, this valuable length-of-record attribute has an inherent problem in that it requires many different observers and observing systems. This can lead to non-uniformity in the datasets and subsequent erroneous conclusions about solar cycle behavior. The sunspot numbers are obtained by counting sunspot groups and individual sunspots on a daily basis. This suggests that the day-to-day and month-to-month variations in these numbers should follow Poisson Statistics and be proportional to the square-root of the sunspot numbers themselves. Examining the historical records of these indices indicates that this is indeed the case - even with Sunspot Area and 10.7 cm Radio Flux. The ratios of the RMS variations to the square-root of the indices themselves are relatively constant with little variation over the phase of each solar cycle or from small to large solar cycles. There are, however, important step-like changes in these ratios associated with changes in observer and/or observer system. Here we show how these variations can be used to construct more uniform datasets.

Hathaway David H.↗

Report on Concepts & Approaches for SSBD for eCHEM

The verification of special nuclear material (SNM) in spent fuel pyroprocessing is an important safeguards challenge. The detection of spontaneous fission (SF) neutrons from curium is an accepted, non-destructive technique that has been applied to verify special nuclear material (SNM) content in used fuel and other materials in the fuel cycle. The nuclear material accounting (NMA) technique at the Korea Atomic Energy Research Institute’s Reference Engineering-scale Pyroprocessing Facility (REPF) is based on the Cm balance technique. Several publications have demonstrated the safeguards benefit from using process monitoring (PM) on nuclear facilities as a complementary measure to NMA. More recently, this concept was expanded and preliminarily demonstrated for pyroprocessing. The concept of Signature Based Safeguards (SBS) is part of this expansion, and is built around the interpretation of input from various sensors in a declared facility coupled with complementary NMA methods to increase confidence and lower standard error inventory differences (SEID). The SBS methodology was conceptually developed and relies on near real time analysis of process monitoring data to detect material diversion complemented by robust containment and surveillance (C/S) measures. This work demonstrates one example of how the SBS framework can be used in the electrorefiner. In this SBS application, a combination of cyclic voltammetry (CV) and neutron counting is applied to track and monitor Pu mass balance. The main purpose of this experiment is to determine if meaningful information can be gained from CV measurements with regard to the Mg/Gd ratio. This data will be coupled with ICP-MS to verify Gd concentrations and analyzed for statistical significance. It is expected the CV data will register a significant change under the off-normal operating conditions. Knowing how to identify and interpret those changes may help inform how to target more traditional neutron counting methods, which could support a more efficient safeguards system. The experimental results will be compared with theoretical calculations and the ERAD simulations.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Passive scheme with a photon-number-resolving detector for monitoring the untrusted source in a plug-and-play quantum-key-distribution system

A passive scheme with a beam splitter and a photon-number-resolving (PNR) detector is proposed to verify the photon statistics of an untrusted source in a plug-and-play quantum-key-distribution system by applying a three-intensity decoy-state protocol. The practical issues due to statistical fluctuation and detection noise are analyzed. The simulation results show that the scheme can work efficiently when the total number of optical pulses sent from Alice to Bob is above 10{sup 8}, and the dark count rate of the PNR detector is below 0.5 counts/pulse, which is realizable with current techniques. Furthermore, we propose a practical realization of the PNR detector with a variable optical attenuator combined with a threshold detector.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

In Situ Ion Counting for Improved Implanted Ion Error Rate and Silicon Vacancy Yield Uncertainty

An in situ counted ion implantation experiment improving the error on the number of ions required to form a single optically active silicon vacancy (SiV) defect in diamond 7-fold compared to timed implantation is presented. Here, traditional timed implantation relies on a beam current measurement followed by implantation with a preset pulse duration. It is dominated by Poisson statistics, resulting in large errors for low ion numbers. Instead, our in situ detection, measuring the ion number arriving at the substrate, results in a 2-fold improvement of the error on the ion number required to generate a single SiV compared to timed implantation. Through postimplantation analysis, the error is improved 7-fold compared to timed implantation. SiVs are detected by photoluminescence spectroscopy, and the yield of 2.98% is calculated through the photoluminescence count rate. Hanbury–Brown–Twiss interferometry is performed on locations potentially hosting single-photon emitters, confirming that 82% of the locations exhibit single photon emission statistics.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Fabrication and characterization of a co-planar detector in diamond for low energy single ion implantation

We demonstrate low energy single ion detection using a co-planar detector fabricated on a diamond substrate and characterized by ion beam induced charge collection. Histograms are taken with low fluence ion pulses illustrating quantized ion detection down to a single ion with a signal-to-noise ratio of approximately 10. We anticipate that this detection technique can serve as a basis to optimize the yield of single color centers in diamond. In conclusion, the ability to count ions into a diamond substrate is expected to reduce the uncertainty in the yield of color center formation by removing Poisson statistics from the implantation process.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Passive decoy-state quantum key distribution with practical light sources

Decoy states have been proven to be a very useful method for significantly enhancing the performance of quantum key distribution systems with practical light sources. Although active modulation of the intensity of the laser pulses is an effective way of preparing decoy states in principle, in practice passive preparation might be desirable in some scenarios. Typical passive schemes involve parametric down-conversion. More recently, it has been shown that phase-randomized weak coherent pulses (WCP) can also be used for the same purpose [M. Curty et al., Opt. Lett. 34, 3238 (2009).] This proposal requires only linear optics together with a simple threshold photon detector, which shows the practical feasibility of the method. Most importantly, the resulting secret key rate is comparable to the one delivered by an active decoy-state setup with an infinite number of decoy settings. In this article we extend these results, now showing specifically the analysis for other practical scenarios with different light sources and photodetectors. In particular, we consider sources emitting thermal states, phase-randomized WCP, and strong coherent light in combination with several types of photodetectors, like, for instance, threshold photon detectors, photon number resolving detectors, and classical photodetectors. Our analysis includes as well the effect that detection inefficiencies and noise in the form of dark counts shown by current threshold detectors might have on the final secret key rate. Moreover, we provide estimations on the effects that statistical fluctuations due to a finite data size can have in practical implementations.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Accurate U 238 ( n , 2 n ) U 237 reaction cross-section measurements from 6.5 to 14.8 MeV

In this study, the cross section for the 238 U(n,2n) 237 U reaction has been measured in the incident neutron energy range from 6.5 to 14.8 MeV in small energy steps using an activation technique. Monoenergetic neutron beams were produced via the 2 H( d,n ) 3 He and 3 H ( d,n ) 4 He reactions. 238 U targets were activated along with Au and Al monitor foils to determine the incident neutron flux. The activity of the reaction products was measured in TUNL's low-background counting facility using high-resolution γ-ray spectroscopy. The results are compared with previous measurements and latest data evaluations. Statistical-model calculations, based on the Hauser-Feshbach formalism, have been carried out using the CoH 3 code and are compared with the experimental results. Finally, the present self-consistent and high-quality data are important for stockpile stewardship and nuclear forensic purposes as well as for the design and operation of fast reactors.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Expected individual benefit of prophylactic platelet transfusions in hemato‐oncology patients based on bleeding risks

Abstract Background Prophylactic platelet transfusions prevent bleeding in hemato‐oncology patients, but it is unclear how any benefit varies between patients. Our aim was to assess if patients with different baseline risks for bleeding benefit differently from a prophylactic platelet transfusion strategy. Study design and methods Using the data from the randomized controlled TOPPS trial (Trial of Platelet Prophylaxis), we developed a prediction model for World Health Organization grades 2, 3, and 4 bleeding risk (defined as at least one bleeding episode in a 30 days period) and grouped patients in four risk‐quartiles based on this predicted baseline risk. Predictors in the model were baseline platelet count, age, diagnosis, disease modifying treatment, disease status, previous stem cell transplantation, and the randomization arm. Results The model had a c‐statistic of 0.58 (95% confidence interval [CI] 0.54–0.64). There was little variation in predicted risks (quartiles 46%, 47%, and 51%), but prophylactic platelet transfusions gave a risk reduction in all risk quartiles. The absolute risk difference (ARD) was 3.4% (CI −12.2 to 18.9) in the lowest risk quartile (quartile 1), 7.4% (95% CI −8.4 to 23.3) in quartile 2, 6.8% (95% CI −9.1 to 22.9) in quartile 3, and 12.8% (CI −3.1 to 28.7) in the highest risk quartile (quartile 4). Conclusion In our study, generally accepted bleeding risk predictors had limited predictive power (expressed by the low c‐statistic), and, given the wide confidence intervals of predicted ARD, could not aid in identifying subgroups of patients who might benefit more (or less) from prophylactic platelet transfusion.

Cornelissen, Loes L.↗

Real-time characterization of partially observed epidemics using surrogate models.

We present a statistical method, predicated on the use of surrogate models, for the 'real-time' characterization of partially observed epidemics. Observations consist of counts of symptomatic patients, diagnosed with the disease, that may be available in the early epoch of an ongoing outbreak. Characterization, in this context, refers to estimation of epidemiological parameters that can be used to provide short-term forecasts of the ongoing epidemic, as well as to provide gross information on the dynamics of the etiologic agent in the affected population e.g., the time-dependent infection rate. The characterization problem is formulated as a Bayesian inverse problem, and epidemiological parameters are estimated as distributions using a Markov chain Monte Carlo (MCMC) method, thus quantifying the uncertainty in the estimates. In some cases, the inverse problem can be computationally expensive, primarily due to the epidemic simulator used inside the inversion algorithm. We present a method, based on replacing the epidemiological model with computationally inexpensive surrogates, that can reduce the computational time to minutes, without a significant loss of accuracy. The surrogates are created by projecting the output of an epidemiological model on a set of polynomial chaos bases; thereafter, computations involving the surrogate model reduce to evaluations of a polynomial. We find that the epidemic characterizations obtained with the surrogate models is very close to that obtained with the original model. We also find that the number of projections required to construct a surrogate model is O(10)-O(10{sup 2}) less than the number of samples required by the MCMC to construct a stationary posterior distribution; thus, depending upon the epidemiological models in question, it may be possible to omit the offline creation and caching of surrogate models, prior to their use in an inverse problem. The technique is demonstrated on synthetic data as well as observations from the 1918 influenza pandemic collected at Camp Custer, Michigan.

59 BASIC BIOLOGICAL SCIENCES↗

Endogenic craters on basaltic lava flows - Size frequency distributions

Circular crater forms, termed collapse depressions, which occur on many basalt flows on the earth have also been detected on the moon and Mars and possibly on Mercury and Io. The admixture of collapse craters with impact craters would affect age determinations of planetary surface units based on impact crater statistics by making them appear anomalously old. In the work described in the present paper, the techniques conventionally used in planetary crater counting were applied to the determination of the size range and size frequency distribution of collapse craters on lava flows in Idaho, California, and New Mexico. Collapse depressions range in size from 3 to 80 m in diameter; their cumulative size distributions are similar to those of small impact craters on the moon.

Greeley, R.↗

Time Evolving Fission Chain Theory and Fast Neutron and Gamma-Ray Counting Distributions

Here, we solve a simple theoretical model of time evolving fission chains due to Feynman that generalizes and asymptotically approaches the point model theory. The point model theory has been used to analyze thermal neutron counting data. This extension of the theory underlies fast counting data for both neutrons and gamma rays from metal systems. Fast neutron and gamma-ray counting is now possible using liquid scintillator arrays with nanosecond time resolution. For individual fission chains, the differential equations describing three correlated probability distributions are solved: the time-dependent internal neutron population, accumulation of fissions in time, and accumulation of leaked neutrons in time. Explicit analytic formulas are given for correlated moments of the time evolving chain populations. The equations for random time gate fast neutron and gamma-ray counting distributions, due to randomly initiated chains, are presented. Correlated moment equations are given for both random time gate and triggered time gate counting. There are explicit formulas for all correlated moments are given up to triple order, for all combinations of correlated fast neutrons and gamma rays. The nonlinear differential equations for probabilities for time dependent fission chain populations have a remarkably simple Monte Carlo realization. A Monte Carlo code was developed for this theory and is shown to statistically realize the solutions to the fission chain theory probability distributions. Combined with random initiation of chains and detection of external quanta, the Monte Carlo code generates time tagged data for neutron and gamma-ray counting and from these data the counting distributions.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗