Search NASA⌕ Search

SEARCH · Search NASA

Results for “Data fitting”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

WE-F-304-03: Optic Nerve/Chiasm Hypofractionated SRS/SRT Dose Tolerance

Stereotactic Body Radiation Therapy (SBRT) was introduced clinically more than twenty years ago, and many subsequent publications have reported safety and efficacy data. The AAPM Working Group on Biological Effects of Hypofractionated Radiotherapy/SBRT (WGSBRT) extracted published treatment outcomes data from extensive literature searches to summarize and construct tumor control probability (TCP) and normal tissue complication probability (NTCP) models for six anatomical regions: Cranial, Head and Neck, Thoracic, Abdominal, Pelvic, and Spinal. In this session, we present the WGSBRT’s work for cranial sites, and recurrent head and neck cancer. From literature-based data and associated models, guidelines to aid with safe and effective hypofractionated radiotherapy treatment are being determined. Further, the ability of existing and proposed radiobiological models to fit these data is considered as to the ability to distinguish between the linear-quadratic and alternative radiobiological models such as secondary cell death from vascular damage, immunogenic, or bystander effects. Where appropriate, specific model parameters are estimated. As described in “The lessons of QUANTEC,” (1), lack of adequate reporting standards continues to limit the amount of useful quantitative information that can be extracted from peer-reviewed publications. Recommendations regarding reporting standards are considered, to enable such reviews to achieve more complete characterization of clinical outcomes. 1 Jackson A, Marks LB, Bentzen SM, Eisbruch A, Yorke ED, Ten Haken RK, Constine LS, Deasy JO. The lessons of QUANTEC: recommendations for reporting and gathering data on dose-volume dependencies of treatment outcome. Int J Radiat Oncol Biol Phys. 2010 Mar 1;76(3 Suppl):S155–60. Learning Objectives: Describe the techniques, types of cancer and dose schedules used in treating recurrent H&N cancers with SBRT List the radiobiological models that compete with the linear-quadratic model in explaining the results of hypofractionated RT Describe the dose/volume metrics that are considered safe in SBRT treatment of tumors near the optic structures. Discuss the efficacy of hypofractionation and dosing schedules used in treating vestibular schwannomas Identify some difficulties in modeling TCP and NTCP for cranial tumors treated with hypofractionation. One moderator, Dr. Grimm, designed and holds intellectual property rights to the DVH Evaluator software tool which is an FDA-cleared product in commercial use, and can analyze some of this data. No others have relevant conflicts of interest.

60 APPLIED LIFE SCIENCES↗

WE-F-304-04: Radiosurgery for Vestibular Schwannomas: Tumor Control Probability Analyses and Recommended Reporting Standards

Stereotactic Body Radiation Therapy (SBRT) was introduced clinically more than twenty years ago, and many subsequent publications have reported safety and efficacy data. The AAPM Working Group on Biological Effects of Hypofractionated Radiotherapy/SBRT (WGSBRT) extracted published treatment outcomes data from extensive literature searches to summarize and construct tumor control probability (TCP) and normal tissue complication probability (NTCP) models for six anatomical regions: Cranial, Head and Neck, Thoracic, Abdominal, Pelvic, and Spinal. In this session, we present the WGSBRT’s work for cranial sites, and recurrent head and neck cancer. From literature-based data and associated models, guidelines to aid with safe and effective hypofractionated radiotherapy treatment are being determined. Further, the ability of existing and proposed radiobiological models to fit these data is considered as to the ability to distinguish between the linear-quadratic and alternative radiobiological models such as secondary cell death from vascular damage, immunogenic, or bystander effects. Where appropriate, specific model parameters are estimated. As described in “The lessons of QUANTEC,” (1), lack of adequate reporting standards continues to limit the amount of useful quantitative information that can be extracted from peer-reviewed publications. Recommendations regarding reporting standards are considered, to enable such reviews to achieve more complete characterization of clinical outcomes. 1 Jackson A, Marks LB, Bentzen SM, Eisbruch A, Yorke ED, Ten Haken RK, Constine LS, Deasy JO. The lessons of QUANTEC: recommendations for reporting and gathering data on dose-volume dependencies of treatment outcome. Int J Radiat Oncol Biol Phys. 2010 Mar 1;76(3 Suppl):S155–60. Learning Objectives: Describe the techniques, types of cancer and dose schedules used in treating recurrent H&N cancers with SBRT List the radiobiological models that compete with the linear-quadratic model in explaining the results of hypofractionated RT Describe the dose/volume metrics that are considered safe in SBRT treatment of tumors near the optic structures. Discuss the efficacy of hypofractionation and dosing schedules used in treating vestibular schwannomas Identify some difficulties in modeling TCP and NTCP for cranial tumors treated with hypofractionation. One moderator, Dr. Grimm, designed and holds intellectual property rights to the DVH Evaluator software tool which is an FDA-cleared product in commercial use, and can analyze some of this data. No others have relevant conflicts of interest.

60 APPLIED LIFE SCIENCES↗

Toward a unified description of hadro- and photoproduction: S-wave {pi}- and {eta}-photoproduction amplitudes

The Chew-Mandelstam (CM) parametrization, which has been used extensively in the two-body hadronic sector, is generalized in this exploratory paper to the electromagnetic sector by simultaneous fits to the {pi}- and {eta}-photoproduction S-wave multipole amplitudes for center-of-mass energies from the pion threshold through 1.61 GeV. We review the CM parametrization in detail to clarify the theoretical content of the said hadronic amplitude analysis and to place the proposed generalized said electromagnetic amplitudes in the context of earlier employed parametrized forms. The parametrization is unitary at the two-body level, which employs four hadronic channels and the {gamma}N electromagnetic channel. We compare the resulting fit to the maid parametrization and find qualitative agreement; although, numerically, the solution is somewhat different. Applications of the extended parametrization to global fits of the photoproduction data and to global fits of the combined hadronic and photoproduction data are discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Constraints on color-octet fermions from a global parton distribution analysis.

We report a parton distribution function analysis of a complete set of hadron scattering data, in which a color-octet fermion (such as a gluino of supersymmetry) is incorporated as an extra parton constituent along with the usual standard model constituents. The data set includes the most up-to-date results from deep inelastic scattering and from jet production in hadron collisions. Another feature is the inclusion in the fit of data from determinations of the strong coupling {alpha}{sub s}(Q) at large and small values of the hard scale Q. Our motivation is to determine the extent to which the global parton distribution function analysis may provide constraints on the new fermion, as a function of its mass and {alpha}{sub s}(M{sub Z}), independent of assumptions such as the mechanism of gluino decays. Based on this analysis, we find that gluino masses as low as 30 to 50 GeV may be compatible with the current hadronic data. Gluino masses below 15 GeV (25 GeV) are excluded if {alpha}{sub s}(M{sub Z}) varies freely (is equal to 0.118). At the outset, stronger constraints had been anticipated from jet production cross sections, but experimental systematic uncertainties, particularly in normalization, reduce the discriminating power of these data.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Functional representation of tissue phantom ratios for photon fields

Purpose: The tissue phantom ratio (TPR) is a common dosimetric quantity used in photon dose calculations. For small photon fields with side lengths less than 4 cm, TPR data hardly exist in literature. In this work, a self-contained functional representation of TPR is proposed, valid for the whole range of clinically relevant depth and field sizes. This is especially useful for small fields shaped by multileaf collimators. Methods: TPRs were measured for quadratic fields with side lengths between 0.4 and 18 cm. The measured data were fitted to a physically meaningful function taking electron buildup, buildup of scattered photons, beam attenuation, and beam hardening into account. The achievable accuracy was tested against measurement and data from the literature. Results: A set of parameters for the proposed function was derived for 6 and 10 MV beams. The comparison of the calculated and the measured data generally yielded a difference of less than 1%. For field sizes below 2 cm, a systematic discrepancy between the author's data and those from Cheng et al. [Med. Phys 34, 3149-3157 (2007)] was found. Conclusions: With the proposed model, TPRs can be calculated for the full range of field sizes and depths required by treatment planning system algorithms and monitor unit check programs with very high accuracy. The method is also useful in detecting and reducing errors in measurement.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Modeling of Salivary Production Recovery After Radiotherapy Using Mixed Models: Determination of Optimal Dose Constraint for IMRT Planning and Construction of Convenient Tools to Predict Salivary Function

Purpose: The mathematical relationship between the dose to the parotid glands and salivary gland production needs to be elucidated. This study, which included data from patients included in a French prospective study assessing the benefit of intensity-modulated radiotherapy (RT), sought to elaborate a convenient and original model of salivary recovery. Methods and Materials: Between January 2001 and December 2004, 44 patients were included (35 with oropharyngeal and 9 with nasopharyngeal cancer). Of the 44 patients, 24 were treated with intensity-modulated RT, 17 with three-dimensional conformal RT, and 2 with two-dimensional RT. Stimulated salivary production was collected for {<=}24 months after RT. The data of salivary production, time of follow-up, and dose to parotid gland were modeled using a mixed model. Several models were developed to assess the best-fitting variable for the dose level to the parotid gland. Results: Models developed with the dose to the contralateral parotid fit the data slightly better than those with the dose to both parotids, suggesting that contralateral and ipsilateral parotid glands are not functionally equivalent even with the same dose level to the glands. The best predictive dose-value variable for salivary flow recovery was the volume of the contralateral parotid gland receiving >40 Gy. Conclusion: The results of this study show that the recommendation of a dose constraint for intensity-modulated RT planning should be established at the volume of the contralateral parotid gland receiving >40 Gy rather than the mean dose. For complete salivary production recovery after 24 months, the volume of the contralateral parotid gland receiving >40 Gy should be <33%. Our results permitted us to establish two convenient tools to predict the saliva production recovery function according to the dose received by the contralateral parotid gland.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Planck intermediate results: XLVII. Planck constraints on reionization history

In this paper, we investigate constraints on cosmic reionization extracted from the Planck cosmic microwave background (CMB) data. We combine the Planck CMB anisotropy data in temperature with the low-multipole polarization data to fit ΛCDM models with various parameterizations of the reionization history. We obtain a Thomson optical depth τ = 0.058 ± 0.012 for the commonly adopted instantaneous reionization model. This confirms, with data solely from CMB anisotropies, the low value suggested by combining Planck 2015 results with other data sets, and also reduces the uncertainties. We reconstruct the history of the ionization fraction using either a symmetric or an asymmetric model for the transition between the neutral and ionized phases. To determine better constraints on the duration of the reionization process, we also make use of measurements of the amplitude of the kinetic Sunyaev-Zeldovich (kSZ) effect using additional information from the high-resolution Atacama Cosmology Telescope and South Pole Telescope experiments. The average redshift at which reionization occurs is found to lie between z = 7.8 and 8.8, depending on the model of reionization adopted. Using kSZ constraints and a redshift-symmetric reionization model, we find an upper limit to the width of the reionization period of Δz < 2.8. In all cases, we find that the Universe is ionized at less than the 10% level at redshifts above z ≃ 10. This suggests that an early onset of reionization is strongly disfavoured by the Planck data. Finally, we show that this result also reduces the tension between CMB-based analyses and constraints from other astrophysical sources.

79 ASTRONOMY AND ASTROPHYSICS↗

Linear growth of structure in massive bigravity

The ghost-free theory of massive gravity with two dynamical metrics has been shown to produce viable cosmological expansion, where the late-time acceleration of the Universe is due to the finite range of the gravitational interaction rather than a nonzero cosmological constant. Here the cosmological perturbations are studied in this theory. The full perturbation equations are presented in a general gauge and analyzed, focusing on subhorizon scales in the quasistatic limit during the matter-dominated era. An evolution equation for the matter inhomogeneities and the parameters quantifying the deviations from general relativistic structure formation are expressed in terms of five functions whose forms are determined directly by the coupling parameters in the theory. The evolution equation has a similar structure to Horndeski-type scalar-tensor theories, exhibiting a modified growth rate and scale-dependence at intermediate wavenumbers. Predictions of the theory are confronted with observational data on both background expansion and large-scale structure, although care must be taken to ensure a model is stable. It is found that while the stable models fit the data well, they feature deviations from the standard cosmology that could be detected or ruled out by near-future experiments.

79 ASTRONOMY AND ASTROPHYSICS↗

Precision Characterization of Gyrotron Window Materials

The response of dielectric material to electromagnetic waves in the millimeter wavelength range (30 to 300 GHz) has received relatively little study and the processes that give rise to absorption in this region are often poorly understood. Understanding the origin of absorption at these wavelengths has basic significance for solid state physics as well as importance for development of technology in this region of the RF spectrum. This project has provided high-quality data on the temperature dependence of the dielectric loss in high-purity, semi-insulating silicon carbide (HPSI SiC), a material that holds much promise for application, especially in devices that must operate in the high power and high frequency regime. Comparison of this experimental data with theoretical predictions for various loss processes provides convincing evidence that the loss in HPSI SiC arises almost entirely from intrinsic lattice loss (ILL) as described by Garin. Fitting the data to this model yields an accurate value for the Debye temperature that characterizes crystalline SiC. In addition, our results refute a previous study(2) which reported much higher loss, attributed to the presence of free charge. The quality of the data acquired in this project is clear evidence for the value of the experimental technique that was employed here. This technique combines the excitation of a high-quality open resonator by a phase-locked backward wave oscillator (BWO) with use of a spectrum analyzer to measure the change in the resonator response curve when the sample is inserted. This system has demonstrated consistent results for very challenging measurements and does not suffer from the artifacts that often arise when using other techniques that rely on thermal sources. The low absorption loss found in HPSI SiC, when combined with its other outstanding material properties, e.g. high thermal conductivity, high tensile strength, and high carrier mobility, should provide incentive for designers to utilize this material to solve the challenging problems that are encountered as devices are pushed to operate at higher frequencies and higher power levels. In particular, for the fusion energy program, it may provide an economical alternative to CVD diamond for certain gyrotron and beam line applications. In addition, the value obtained for the Debye temperature provides an important datum for modeling the crystalline structure of SiC. Clearly SiC is a unique material with few competitors and should see wider utilization.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Dynamical coupled channels calculation of pion and omega meson production

The dynamical coupled-channels approach developed at the Excited Baryon Analysis Center is extended to include the {omega}N channel to study {pi}- and {omega}-meson production induced by scattering pions and photons from the proton. Six intermediate channels, including {pi}N, {eta}N, {pi}{delta}, {sigma}N, {rho}N, and {omega}N, are employed to describe unpolarized and polarized data. Bare parameters in an effective hadronic Lagrangian are determined in a fit to the data for {pi}N{yields}{pi}N, {gamma}N{yields}{pi}N, {pi}{sup -}p{yields}{omega}n, and {gamma}p{yields}{omega}p reactions at center-of-mass energies from threshold to W<2.0 GeV. The T matrix determined in these fits is used to calculate the photon beam asymmetry for {omega}-meson production and the {omega}N{yields}{omega}N total cross section and {omega}N-scattering lengths. The calculated beam asymmetry is in good agreement with the observed in the range of energies near threshold to W < or approx. 2.0 GeV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Oxalic Acid Adsorption on Rutile: Experiments and Surface Complexation Modeling to 150 °C

Here, we characterize oxalate adsorption by rutile in NaCl media (0.03 and 0.30 m) and between pH 3 and 10 over a wide temperature range which includes the near hydrothermal regime (10–150 °C). Oxalate adsorption increases with decreasing pH (as is typical for anion binding by metal oxides), but systematic trends with respect to ionic strength or temperature are absent. Surface complexation modeling (SCM) following the CD-MUSIC formalism, and as constrained by molecular modeling simulations and IR spectroscopic results from the literature, is used to interpret the adsorption data. The molecular modeling simulations, which include molecular dynamics simulations supported by free-energy and ab initio calculations, reveal that oxalate binding is outer-sphere, albeit via strong hydrogen bonds. Conversely, previous IR spectroscopic results conclude that various types of inner-sphere complexes often predominate. SCMs constrained by both the molecular modeling results and the IR spectroscopic data were developed, and both fit the adsorption data equally well. We conjecture that the discrepancy between the molecular simulation and IR spectroscopic results is due to the nature of the rutile surfaces investigated, that is, the perfect (110) crystal faces for the molecular simulations and various rutile powders for the IR spectroscopy studies. Although the (110) surface plane is most often dominant for rutile powders, a variety of steps, kinks, and other types of surface defects are also invariably present. Hence, we speculate that surface defect sites may be primarily responsible for inner-sphere oxalate adsorption, although further study is necessary to prove or disprove this hypothesis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Planck 2013 results. XI. All-sky model of thermal dust emission

This work introduces an all-sky model of dust emission from the Planck 353, 545, and 857 GHz, and IRAS 100 μm data. Using a modified blackbody fit to the data we present all-sky maps of the dust optical depth, temperature, and spectral index over the 353-3000 GHz range. This model is a good representation of the IRAS and Planck data at 5' between 353 and 3000 GHz (850 and 100 μm). It shows variations of the order of 30% compared with the widely-used model of Finkbeiner, Davis, and Schlegel. The Planck data allow us to estimate the dust temperature uniformly over the whole sky, down to an angular resolution of 5', providing an improved estimate of the dust optical depth compared to previous all-sky dust model, especially in high-contrast molecular regions where the dust temperature varies strongly at small scales in response to dust evolution, extinction, and/or local production of heating photons. An increase of the dust opacity at 353 GHz, τ 353 / N H , from the diffuse to the denser interstellar medium (ISM) is reported. It is associated with a decrease in the observed dust temperature, T obs , that could be due at least in part to the increased dust opacity. We also report an excess of dust emission at H I column densities lower than 10 20 cm -2 that could be the signature of dust in the warm ionized medium. In the diffuse ISM at high Galactic latitude, we report an anticorrelation between τ 353 / N H and T obs while the dust specific luminosity, i.e., the total dust emission integrated over frequency (the radiance) per hydrogen atom, stays about constant, confirming one of the Planck Early Results obtained on selected fields. This effect is compatible with the view that, in the diffuse ISM, T obs responds to spatial variations of the dust opacity, due to variations of dust properties, in addition to (small) variations of the radiation field strength. The indication is that in the diffuse high-latitude ISM τ 353 is not as reliable a tracer of dust column density as we conclude it is in molecular clouds where the correlation of τ 353 with dust extinction estimated using colour excess measurements on stars is strong. To estimate Galactic E(B-V) in extragalactic fields at high latitude we develop a new method based on the thermal dust radiance, instead of the dust optical depth, calibrated to E(B -V) using reddening measurements of quasars deduced from Sloan Digital Sky Survey data.

79 ASTRONOMY AND ASTROPHYSICS↗

Experimental Results and Modeling of Low-Heat-Capacity TES Microcalorimeters for Soft-X-ray Spectroscopy

Transition-edge-sensor (TES) X-ray microcalorimeters have mostly been targeted at mid-band energies from 0.05-10 keV and high energies to above 100 keV. However, many other optimizations are possible. Here we present results from devices optimized for soft X-ray applications. For spectroscopy below 1 keV, the X-ray stopping power and heat capacity (C) of the TES itself are high enough that we can omit a separate absorber. The resulting devices have low C and the best-achievable energy resolution should be under 1 eV. We are interested in pursuing such devices primarily for astrophysical applications and laboratory astrophysics at LLNL's Electron-Beam Ion Trap. To this end, we have studied arrays in which 'bare' TESs are interspersed with broad-band pixels that have absorbers. By extending the absorbers to cover the area where the leads contact the low-energy pixels, we have eliminated a significant source of non-Gaussian detector response. The bare devices are in a different regime from our typical devices in that C is ten times lower and the conductance to the bath is four times lower. We have explored this regime through simultaneous fitting of noise and impedance data. These data cannot be fit by the simple model we employ to describe our typical broad-band devices. In this contribution we present X-ray spectra and the results from modeling.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Viscous dissipative Chaplygin gas dominated homogenous and isotropic cosmological models

The generalized Chaplygin gas, which interpolates between a high density relativistic era and a nonrelativistic matter phase, is a popular dark energy candidate. We consider a generalization of the Chaplygin gas model, by assuming the presence of a bulk viscous type dissipative term in the effective thermodynamic pressure of the gas. The dissipative effects are described by using the truncated Israel-Stewart model, with the bulk viscosity coefficient and the relaxation time functions of the energy density only. The corresponding cosmological dynamics of the bulk viscous Chaplygin gas dominated universe is considered in detail for a flat homogeneous isotropic Friedmann-Robertson-Walker geometry. For different values of the model parameters we consider the evolution of the cosmological parameters (scale factor, energy density, Hubble function, deceleration parameter, and luminosity distance, respectively), by using both analytical and numerical methods. In the large time limit the model describes an accelerating universe, with the effective negative pressure induced by the Chaplygin gas and the bulk viscous pressure driving the acceleration. The theoretical predictions of the luminosity distance of our model are compared with the observations of the type Ia supernovae. The model fits well the recent supernova data. From the fitting we determine both the equation of state of the Chaplygin gas, and the parameters characterizing the bulk viscosity. The evolution of the scalar field associated to the viscous Chaplygin fluid is also considered, and the corresponding potential is obtained. Hence the viscous Chaplygin gas model offers an effective dynamical possibility for replacing the cosmological constant, and for explaining the recent acceleration of the universe.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Physics-Informed Neural Networks for Heat Transfer Problems

Abstract Physics-informed neural networks (PINNs) have gained popularity across different engineering fields due to their effectiveness in solving realistic problems with noisy data and often partially missing physics. In PINNs, automatic differentiation is leveraged to evaluate differential operators without discretization errors, and a multitask learning problem is defined in order to simultaneously fit observed data while respecting the underlying governing laws of physics. Here, we present applications of PINNs to various prototype heat transfer problems, targeting in particular realistic conditions not readily tackled with traditional computational methods. To this end, we first consider forced and mixed convection with unknown thermal boundary conditions on the heated surfaces and aim to obtain the temperature and velocity fields everywhere in the domain, including the boundaries, given some sparse temperature measurements. We also consider the prototype Stefan problem for two-phase flow, aiming to infer the moving interface, the velocity and temperature fields everywhere as well as the different conductivities of a solid and a liquid phase, given a few temperature measurements inside the domain. Finally, we present some realistic industrial applications related to power electronics to highlight the practicality of PINNs as well as the effective use of neural networks in solving general heat transfer problems of industrial complexity. Taken together, the results presented herein demonstrate that PINNs not only can solve ill-posed problems, which are beyond the reach of traditional computational methods, but they can also bridge the gap between computational and experimental heat transfer.

Engineering↗

Radiation dose assessment in a 320-detector-row CT scanner used in cardiac imaging

Purpose: In the present era of cone-beam CT scanners, the use of the standardized CTDI{sub 100} as a surrogate of the idealized CTDI is strongly discouraged and, consequently, so should be the use of the dose-length product (DLP) as an estimate of the total energy imparted to the patient. However, the DLP is still widely used as a reference quantity to normalize the effective dose for a given scan protocol mainly because the CTDI{sub 100} is an easy-to-measure quantity. The aim of this article is therefore to describe a method for radiation dose assessment in large cone-beam single axial scans, which leads to a straightforward estimation of the total energy imparted to the patient. The authors developed a method accessible to all medical physicists and easy to implement in clinical practice in an attempt to update the bridge between CT dosimetry and the estimation of the effective dose. Methods: The authors used commercially available material and a simple mathematical model. The method described herein is based on the dosimetry paradigm introduced by the AAPM Task Group 111. It consists of measuring the dose profiles at the center and the periphery of a long body phantom with a commercial solid-state detector. A weighted dose profile is then calculated from these measurements. To calculate the CT dosimetric quantities analytically, a Gaussian function was fitted to the dose profile data. Furthermore, the Gaussian model has the power to condense the z-axis information of the dose profile in two parameters: The single-scan central dose, f(0), and the width of the profile, {sigma}. To check the energy dependence of the solid-state detector, the authors compared the dose profiles to measurements made with a small volume ion chamber. To validate the overall method, the authors compared the CTDI{sub 100} calculated analytically to the measurement made with a 100 mm pencil ion chamber. Results: For the central and weighted dose profiles, the authors found a good agreement between the measured dose profile data and the fitted Gaussian functions. The solid-state detector had no energy dependence--within the energy range of interest--and the analytical model succeeded in reproducing the absolute dose values obtained with the pencil ion chamber. For the case of large cone-beam single axial scans, the quantity that better characterizes the total energy imparted to the patient is the weighted dose profile integral (DPI{sub w}). The DPI{sub w} can be easily determined from the two parameters that define the Gaussian functions: f(0) and {sigma}. The authors found that the DLP underestimated the total energy imparted to the patient by more than 20%. The authors also found that the calculated CT dosimetric quantities were higher than those displayed on the scanner console. Conclusions: The authors described and validated a method to assess radiation dose in large cone-beam single axial scans. This method offers a simple and more accurate estimation of the total energy imparted to the patient, thus offering the possibility to update the bridge between CT dosimetry and the estimation of the effective dose for cone-beam CT examinations in radiology, nuclear medicine, and radiation therapy.

61 RADIATION PROTECTION AND DOSIMETRY↗

A New 1-step Arrhenius Decomposition Model for PBX 9501: Calibration with Isochoric-Adiabatic High-Activation-Energy Asymptotics and Uncertainty Quantification

Here we present a new 1-step Arrhenius thermal decomposition model of PBX 9501. As opposed to previous studies, we use high-energy asymptotic theory, and previously published equations of state to parameterize the model to experimental critical-time data. The model parameters were fit to experimental data using a bootstrapping procedure to capture the effects of experimental uncertainty. Subsequent implementation of the model in a chemicalkinetics ODE solver shows good agreement of times to ignition vs initial temperature in isochoric thermal explosion calculations with the results of the high-energy asymptotic theory. We also compare the resultant ZND structures to those of one of our previously calibrated burn models.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

NEUTRON STAR MASS–RADIUS CONSTRAINTS USING EVOLUTIONARY OPTIMIZATION

The equation of state of cold supra-nuclear-density matter, such as in neutron stars, is an open question in astrophysics. A promising method for constraining the neutron star equation of state is modeling pulse profiles of thermonuclear X-ray burst oscillations from hot spots on accreting neutron stars. The pulse profiles, constructed using spherical and oblate neutron star models, are comparable to what would be observed by a next-generation X-ray timing instrument like ASTROSAT , NICER , or a mission similar to LOFT . In this paper, we showcase the use of an evolutionary optimization algorithm to fit pulse profiles to determine the best-fit masses and radii. By fitting synthetic data, we assess how well the optimization algorithm can recover the input parameters. Multiple Poisson realizations of the synthetic pulse profiles, constructed with 1.6 million counts and no background, were fitted with the Ferret algorithm to analyze both statistical and degeneracy-related uncertainty and to explore how the goodness of fit depends on the input parameters. For the regions of parameter space sampled by our tests, the best-determined parameter is the projected velocity of the spot along the observer’s line of sight, with an accuracy of ≤3% compared to the true value and with ≤5% statistical uncertainty. The next best determined are the mass and radius; for a neutron star with a spin frequency of 600 Hz, the best-fit mass and radius are accurate to ≤5%, with respective uncertainties of ≤7% and ≤10%. The accuracy and precision depend on the observer inclination and spot colatitude, with values of ∼1% achievable in mass and radius if both the inclination and colatitude are ≳60°.

79 ASTRONOMY AND ASTROPHYSICS↗