Search NASA⌕ Search

SEARCH · Search NASA

Results for “Deployable Power Systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

NASA’s Strategic Analysis Cycle 2021 (SAC21) Human Mars Architecture

[Note: this is the presentation for a companion paper with the following abstract] The National Aeronautics and Space Administration’s (NASA) Mars Architecture Team (MAT) was challenged to develop a mission architecture capable of transporting humans to the surface of Mars and back as fast—and as soon—as practical. This challenge represented a significant departure from previous approaches that minimized Earth-launched mass and maximized in-space transportation efficiency, often resulting in roundtrip missions of three years or more in duration. In the interest of crew health, MAT’s cross-Agency team of subject matter experts was challenged to develop an architecture capable of shortening crew time away from Earth to about two years. MAT was given specific mission constraints, such as number of crew, as well as mandates to minimize surface infrastructure as much as possible and to incorporate nuclear transportation options. The resulting MAT-developed concept, referred to here as the Strategic Analysis Cycle 2021 (SAC21) architecture, leverages Artemis elements and emerging commercial capabilities for cargo and logistics launches, and features a hybrid Nuclear Electric Propulsion (NEP)/Chemical transportation system able to complete the 1.8 billion kilometer round-trip journey to Mars and back in 760 to 850 days transit time for the 2039 Earth departure opportunity. Three Mars Descent Systems (MDS), each capable of landing about 25 metric tons of useful cargo on the surface of Mars, would be pre-deployed in advance of crew departure from Earth; two of these MDS’s would deliver a partially fueled Mars Ascent Vehicle (MAV), a fission power system, surface mobility, and additional MAV propellant. To minimize surface infrastructure, only two of the four Mars crew would descend and live in an MDS-landed pressurized rover, exploring the martian surface for 30 martian days, or sols, before returning to Mars orbit aboard their MAV and rejoining the other two crew on the Deep Space Transport for the Earth return voyage. Specifics of many of these architecture elements are detailed in separate technical publications; this paper outlines the end-to-end integrated architecture performance and concept of operations, including synergies with Artemis lunar architecture elements. It is important to note that NASA does not have a formal human Mars program and no decisions have been made; the architecture described here is intended to fill in an often-overlooked corner of the trade space, helping to complete the menu of options available to decision-makers as they chart the course for humans to Mars. Note: Slide 9 contains a ~2 min video, best viewed when downloaded. Once downloaded to begin video you may be requested to hit options and Trust this document.

Long-duration spaceflight↗

Deployment of Advanced Electroanalytical Sensors in the Kairos Power Engineering Test Unit (ETU) (Final CRADA Report)

This document serves as a summary report for the work conducted under CRADA 2022-22119 between Argonne National Laboratory and Kairos Power LLC. As part of this project, Argonne and Kairos worked to develop an advanced electrochemical system and testing protocol for the Kairos Power Enineering Test Unit (ETU), an industrial scale 14 ton molten FLiBe salt system. The main goals were (1) measurements of fundamental properties for key salt species, (2) the deployment and operations of sensors in the ETU, and (3) the development of automated approaches to analyze the measurements.

42 ENGINEERING↗

Sorption-based atmospheric water harvesting device

A water-harvesting system can operate with a material that can take up and release water with minimum energy requirements and powered by low-grade energy sources, such as sunlight, in order to potentially allow its deployment into households, especially those located in sunny regions. A water-harvesting method and system can include vapor adsorption using a porous metal-organic framework. In certain embodiments, the porous metal-organic framework can include metal-organic framework in ambient air with low relative humidity, typical of the levels found in most dry regions of the world.

42 ENGINEERING↗

Sorption-based atmospheric water harvesting device

A water-harvesting system can operate with a material that can take up and release water with minimum energy requirements and powered by low-grade energy sources, such as sunlight, in order to potentially allow its deployment into households, especially those located in sunny regions. A water-harvesting method and system can include vapor adsorption using a porous metal-organic framework. In certain embodiments, the porous metal-organic framework can include metal-organic framework in ambient air with low relative humidity, typical of the levels found in most dry regions of the world.

42 ENGINEERING↗

Clean Grid Vision: A U.S. Perspective - Chapter 2. Distribution Issues and Tools

The continued growth in distributed energy resources is fundamentally changing the way the distribution system is operated and planned. Additionally, an increasing number of grid issues are being regularly experienced by distribution engineers within an increasing number of utilities. Fortunately, these fundamental changes and increasingly regular issues are being addressed via continual improvements in existing distribution system modeling tools—for both tools used by industry and researchers—and via novel modeling methods, which are combining transmission and distribution system modeling to investigate new, often complex, system interactions at the transmission/distribution power system interface. As DERs continue to increase more and more utilities, regulators, and developers are finding usable solutions in the deployment of smart inverters with ever more capable functionalities. This increase in functionality is welcome but comes at the cost of more complex analysis when determining what specific settings should be used for an individual interconnection. With more time, experience, and likely the further development of advanced analysis tools, even higher levels of DER integration will result in a reliable, resilient, low-cost, and safely operating grid.

24 POWER TRANSMISSION AND DISTRIBUTION↗

The Potential to Improve the Value of U.S. Geothermal Electricity Generation Through Flexible Operations

Geothermal power plants have typically been operated as baseload plants. The recent expansion of wind and solar power generation creates a potential opportunity to increase the value of geothermal generation through flexible operations. In recent years, California’s wholesale electricity markets have exhibited frequent, short-term periods of negative pricing, indicating that additional flexibility would be valued in the market. Here, we examine local nodal hourly price records at all geothermal plants located in the western United States. We describe how the frequency and temporal characteristics of negative pricing episodes have changed over recent years. Based on these price series, we calculate the value of multiple strategies of flexible operations. Additionally, we use the estimates of future prices, developed through a capacity-expansion model and a dispatch model, to explore how the value of such flexible operations might change along with further penetration of variable renewable power sources. Based on the historical pricing records, we find that simple curtailment of operations during negative pricing episodes could increase the average energy value by 1–2 dollars per MWh and that allowing for increased production during limited high-priced hours, in addition to curtailment during negative priced hours, could potentially double the increase in value (up to 4 dollars per MWh). The forward-looking simulations indicate reduced values of flexibility from geothermal power despite higher penetrations of variable renewable energy. This result highlights the possibility that increasing flexibility options throughout the system may counteract the influence of increased variable renewable energy deployment.

15 GEOTHERMAL ENERGY↗

Solar Radiometer Instrumentation Evaluation: Cooperative Research and Development (Final Report, CRADA Number CRD-16-00619)

The purpose and intent of this agreement is to evaluate newly manufactured thermopile pyranometers and spectroradiometers. The purpose also extends to provide a framework for Participant to conduct research to improve and develop new radiometric devices and application in the future. The overall objective is to provide more accurate, site-specific, long-term, continuous measurements of the solar resources needed by industry to increase the deployment and improve the operations of photovoltaic and concentrating solar power plants. This CRADA addresses the needs for proven solar irradiance measurement to validate resource assessment models and generate high quality data used for site selection, energy system design, deployment, maintenance, and operation. This work will be conducted at NREL and Participant facilities. This project will place instrumentation at the NREL Solar Radiation Research Laboratory (SRRL) in cooperation with EKO Instruments, USA. Participant instruments will be deployed for the purpose of evaluation under controlled conditions. The scope of the project will be a 3 years-long segmented comparison of the instruments vs. other NREL baseline instruments with a well-characterized history. These evaluations will include planned improvements to instruments as well as extensions of future instrument applications. The final evaluation will be a written report similar to the work done by Wilcox and Myers (see http://www.nrel.gov/docs/fy09osti/44627.pdf).

14 SOLAR ENERGY↗

Analyzing the Inflation Reduction Act and the Bipartisan Infrastructure Law for Their Effects on Nuclear Cost Data

Decarbonizing to meet aggressive climate change mitigation targets requires energy transition within all sectors. In the industrial sector, emissions will need to decrease by 65–90% by 2050 to avert global warming greater than 1.5°C (IPCC 2022). The Inflation Reduction Act (IRA), Bipartisan Infrastructure Law (BIL), and Defense Production Act (DPA) have clean energy requirements and provide financial incentives to accelerate the use of clean energy technologies in the industrial sector. It is important to note that IRA is the most extensive action ever taken by Congress and the U.S. government to combat climate change (US CBO 2021, 2022). The energy system provisions comprise most of the estimated climate and energy support. A better understanding of those provisions in the above mentioned acts and laws is crucial to assessing their impact on the equivalent energy costs to the power plant owners (impact on net revenue in $/MWh) across different energy technologies, market deployment potential offered to different energy technologies applications, and energy system research modeling. The purpose of the report is to shed light on IRA and BIL provisions with particular attention to impacts on the nuclear industry. The report also seeks to understand potential equivalent energy cost savings for nuclear energy technologies from other laws and programs in conjunction with IRA, BIL, loan program guarantees, and DPA. The report reviews recent legislation on energy policy and translates that policy to impacts on equivalent nuclear costs for the purpose of modeling policy in energy scenarios.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Advanced Airfoil Cooling Schemes to Increase Efficiency in Gas Turbines for Combined Heat and Power Applications

This report describes a three-year interdisciplinary effort funded by the U.S. Department of Energy’s (DOE) Energy Efficiency and Renewable Energy/Advanced Manufacturing Office (EERE/AMO) to promote market penetration of combined heat and power (CHP) technologies. Prior studies have shown the technical potential for CHP in the United States is much larger than the current deployment of CHP systems. A large portion of the technical potential CHP market aligns with small (<20 MWe) gas turbines. CHP systems are an attractive alternative to reduce greenhouse gas (GHG) emissions. For example, CHP systems can reduce GHG emissions by 30–40% relative to a conventional boiler and power configuration. These GHG emission reductions are “avoided emissions” which means no CO 2 separation or sequestration is required. This report describes an effort to use additive manufacturing (AM) technologies and advanced airfoil cooling designs to increase the turbine inlet temperature by 100 °C for small gas turbines typically used in CHP systems. At the beginning of this effort, baseline performance data for small gas turbines was not available, and the potential benefits of cooling system improvements were not quantified in the available literature.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Epistemology of voltage control in DER-rich power system

Despite the recent development of several scalable, robust, and resilient control approaches with superior convergence properties considering an increasing penetration of distributed energy resources (DERs), cognitive oversights often simplify several aspects of the cyber–physical power system in the controller development. Here, following the identification of the limitations of classical controller definitions, we justify alternative definitions of voltage control approaches classifiers considering three inter-disciplinary domains: (i) power system, (ii) optimization and decision-making, and (iii) networking and cyber-security, to develop a taxonomy for helping in real-world comparative performance analysis and deployability of these controllers. We observe that classical and introduced domain-based definitions together can better classify the control algorithms.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Quantitative Risk Analysis of High Safety Significant Safety-related Digital Instrumentation and Control Systems in Nuclear Power Plants using IRADIC Technology

This report documents the activities performed by Idaho National Laboratory (INL) during fiscal year (FY) 2021 for the U.S. Department of Energy (DOE) Light Water Reactor Sustainability (LWRS) Program, Risk Informed Systems Analysis (RISA) Pathway, digital instrumentation and control (DI&C) Risk Assessment project. In FY-2019, the RISA Pathway initiated a project to develop a risk assessment strategy for delivering a strong technical basis to support effective, licensable, and secure DI&C technologies for digital upgrades/designs. An integrated risk assessment technology for the DI&C systems (IRADIC technology) was proposed for this strategy, which aims to (1) provide a best-estimate risk-informed capability to quantitatively and accurately estimate the safety margin obtained from plant modernization, especially for the High Safety Significant Safety-related (HSSSR) DI&C systems, (2) develop an advanced risk assessment technology to support transition from analog to DI&C technologies for nuclear industry, (3) assure the long-term safety and reliability of vital HSSSR DI&C systems, (4) reduce uncertainty in costs and support integration of DI&C systems in the plant. To achieve these technical goals and deal with the expensive licensing justifications from regulatory insights, the IRADIC technology is instructive for nuclear vendors and utilities to effectively lower the costs associated with digital compliance and speed industry advances by: (1) defining an integrated risk-informed analysis process for DI&C upgrade, including hazard analysis, reliability analysis, and consequence analysis, (2) applying systematic and risk-informed tools to address common cause failures (CCFs) and quantify responding failure probabilities for DI&C technologies, particularly software CCFs, (3) evaluating the impact of digital failures at the individual level, system level, and plant level, (4) providing insights and suggestions on designs to manage the risks; thus, to support the development, licensing, and deployment of advanced DI&C technologies on nuclear power plant (NPPs). In this report, an approach for performing software CCF analysis, given limited data, is developed and demonstrated using a case study of a highly redundant digital reactor trip system. Consequence analysis is also performed based on different accident scenarios. Results indicate that plant modernization including the improvement of HSSSR DI&C systems will make great benefits to plant safety by providing more safety margins to accident management. In addition, a novel approach is proposed in this report for the quantification of software hazards when sufficient operational and testing data available. The method incorporates software development quality as well as strong analysis techniques to identify and link software defects to potential failure modes. The approach includes both semantic and test-based analysis to detect failures that can exist in different stages of the software development life cycle. This method is applied to an advanced human system interface relevant to reactor trip safety developed from the APR 1400 design.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Austin Sustainable and Holistic Integration of Energy Storage and Solar PV [Austin SHINES]. Final Report, Version 2

The Austin SHINES project and solution is a software management platform, for an electric grid with a high penetration of dispersed photovoltaic (PV) solar generation sites, which maintains the traditional power quality and reliability associated with grid service. This project developed and deployed the platform as a Distributed Energy Resource Management System (DERMS), engaging multiple advanced controls, to evaluate operation and optimization of a fleet of diverse DER assets, installed at several locations among Austin Energy’s customers and distribution system. The project also produced a methodology to create a replicable DERMS template, adaptable to other regions and market structures. Last, Austin SHINES aimed to demonstrate the solution’s methodology would enable the DER grid ecosystem to serve load at a technical cost (System Levelized Cost of Electricity, or System LCOE) of less than the U.S. Department of Energy SHINES program metric of $0.14/kWh, in a defined boundary, while enabling a high penetration of distributed PV. Research was categorized in 6 reports (Final Deliverables = FD) listed below, with titles and descriptions indicating which area of understanding was investigated: FD-1: System Levelized Cost of Electricity (System LCOE) Methodology The creation and use of the System LCOE to Serve Load metric that encompasses the holistic, system-level costs and benefits of all resources, and enables them to be evaluated based on their ability to support an efficient and low-cost integrated grid ecosystem. FD-2: Software Platform Product Description The creation of new DER control methodologies deployable within a utility-grade software platform that enable DER's to maximize their benefit within a grid, that is capable of serving load enabling a high penetration of distributed PV generation. FD-3: Optimal Design Methodology Optimal design methodologies for individual DER installations that enable utilities to determine the optimal combinations and sizing for individual DER sites. FD-4: Austin SHINES Ownership and Operation Models for DER System Performance A comparison of multiple DER aggregation and ownership methodologies including direct utility control, third-party aggregator, and autonomous. FD-5: Economic Modeling & Optimization A comparison of multiple DER technology mixes and configurations within the distribution system, providing insight into an optimal blend of technologies that best enable the distribution system to serve load at the lowest cost at high penetrations of solar. FD-6: Fielded Assets Deployed DER assets within the Austin Energy SHINES circuits. Austin SHINES provided an opening for state-of-the-art technology products to be deployed, providing a rich opportunity for improving how each of the products perform as stand-alone products, and in concert with other complementary products. The Austin SHINES project comprised of two key metrics for System LCOE: SystemLCOE_SHINES<$0.14/kWh Modeled ΔSystemLCOE_SHINES/ΔSystemLCOE_Base≥20% at same solar penetration The System LCOE calculation uses the costs of the utility-owned infrastructure as it exists today, the cost of the DERs that exist in the system today, and the cost of the purchase of energy from ERCOT wholesale markets over the course of the calendar year. All costs are on an annualized basis. The capital and operating costs are derived from the rate case, which produces a yearly cost. The net cost of energy and services imported to the system is integrated over the test year, as is the load served and solar penetration. The first metric was easily achieved by every scenario considered. The goal was set when the Department of Energy’s SHINES Funding Opportunity Announcement was written in 2015 and was a more difficult target at the time. Due mostly to rapidly declining costs for DERs and the significant decrease in the Electric Reliability Council of Texas (ERCOT) energy market prices, which results in lower net cost of energy purchases, the System LCOE is well below this target for all scenarios considered. A fleet of DERs can assume different mixtures, each of which serves the load at a different LCOE. The optimal mixture of DERs serves load at the smallest System LCOE. The second metric (hereinafter %delta metric) asks that the holistic DERMS controls reduce the incremental cost above the baseline of going to a high solar penetration future by at least 20% as compared to the case of a DER deployment with no sophisticated controls (autonomous). Many comparison sets were created throughout this project. Physical technology was installed for informing utility engineering and testing several types of operational control schemes, through the DERMS. The types of operational control which were compared for valuation of the System LCOE Metric were: Holistic control = using the full suite of the DERMS platform to decide and optimize how/why the systems operate depending on weather, market, and reliability signal input. Autonomous control = a local mode at the asset site, wherein a schedule operates the asset, with visibility into performance only No control = the baseline for comparing value against the other two types of control The types of ownership control included: Direct Utility control = the utility dispatches a signal to each asset Third-Party Aggregator = a third party aggregates a fleet of assets and the utility dispatches one signal for all Autonomous = a local mode is set for operation at the asset site, wherein a schedule operates the asset, with visibility into performance only The types of control methodologies deployable within a utility-grade software platform included: Utility Peak Load Reduction = Lower transmission cost obligation Day-Ahead Energy Arbitrage = Realize economic value through price differential Real-Time Price Dispatch = Realize economic value from real-time price spikes Voltage support = Reduce losses and increase solar generation Distribution Congestion Management = Increase local grid reliability Demand Charge Reduction = Lower customer bills and realize system benefit The fielded assets deployed for the project were: Utility Scale Kingsbery Energy Storage System: 1.5 MW / 3 MWh Li-Ion battery storage Mueller Energy Storage System: 1.75 MW / 3.2 MWh Li-Ion battery storage, 7 Energy Storage Units (250 kW each) La Loma Community Solar: 2.6 MW Commercial Scale Aggregated storage installations at 3 sites, with existing solar (300+ kW): One 18 kW / 36 kWh Li-Ion battery storage Two 72 kW / 144 kWh Li-Ion battery storage Residential Scale Aggregated storage installations: -Six stationary battery storage systems (10 kWh each) at homes with existing solar -One Electric Vehicle installed as Vehicle-to-Grid (V2G) Utility-Controlled Solar via Smart Inverters at 12 homes Autonomously-Controlled Smart Inverters at 6 homes Over the course of the project, Austin SHINES undertook installing more than 3 MW of distributed battery energy storage, smart PV inverters, a DER control platform, and other enabling technologies utilizing customer and utility locations and aggregation models. All of these resources were to be integrated and optimized at the utility level. DER assets and control methodologies were designed to achieve a credible pathway to a System LCOE for energy delivered to load of $0.14//kWh or less by 2020, while maximizing distributed solar generation and maintaining acceptable standards of power quality. The project also established a template for other regions to follow, to maximize the adoption of distributed solar PV in support of an economic and efficient grid. In total, the Austin SHINES project added value to the DER subject area in each layer of integration. From utility, to commercial to residential scales, the sheer hierarchy of communication and coordination was a significant accomplishment in addition to learnings from what these communications revealed was unique to each. Economically, the most effective method demonstrated was the criticality of planning phases. Contingencies and multiple projection scenarios helped guide the project to deploy optimal design as close as feasible, in real world conditions. The project and reports will serve public benefit by outlining specific areas of DER strategy and installation where many stakeholders and needs can be addressed with improved efficiency. Overall, communities and utilities should use the results to guide the increasing options available for powering the grid with DER, renewables, and carbon considerate energy.

14 SOLAR ENERGY↗

Infrared Heater Used in Qualification Testing of International Space Station Radiators

Two heat rejection radiator systems for the International Space Station (ISS) have undergone thermal vacuum qualification testing at the NASA Glenn Research Center (GRC), Plum Brook Station, Sandusky, Ohio. The testing was performed in the Space Power Facility (SPF), the largest thermal vacuum chamber in the world. The heat rejection system radiator was tested first; it removes heat from the ISS crew living quarters. The second system tested was the photovoltaic radiator (PVR), which rejects heat from the ISS photovoltaic arrays and the electrical power-conditioning equipment. The testing included thermal cycling, hot- and cold-soaked deployments, thermal gradient deployments, verification of the onboard heater controls, and for the PVR, thermal performance tests with ammonia flow. Both radiator systems are orbital replacement units for ease of replacement on the ISS. One key to the success of these tests was the performance of the infrared heater system. It was used in conjunction with a gaseous-nitrogen-cooled cryoshroud in the SPF vacuum chamber to achieve the required thermal vacuum conditions for the qualification tests. The heater, which was designed specifically for these tests, was highly successful and easily met the test requirements. This report discusses the heating requirements, the heater design features, the design approach, and the mathematical basis of the design.

Ziemke, Robert A.↗

Markov Process to Evaluate the Value Proposition of a Risk-Informed Predictive Maintenance Strategy

To achieve high-capacity factors, the nuclear fleet has relied on labor-intensive and time-consuming operation and preventive maintenance programs for plant systems. Manually performed inspection, calibration, testing, and maintenance of plant assets at periodic frequencies, along with time-based replacement of assets irrespective of condition, have resulted in a costly, labor-centric business model. Fortunately, there are technologies that can eliminate unnecessary preventive maintenance activities by deploying risk-informed predictive maintenance, enabling the transition to a technology-centric business model. The technology-centric business model will enable plants to optimize and automate maintenance activities, leading to cost reductions since labor is a rising cost and technology is a declining cost. The implementation of scalable technologies and methodologies across plant systems and across the nuclear fleet is critical for successful deployment of a risk-informed predictive maintenance strategy at commercial nuclear power plants. The work presented in the report is being developed as part of a collaborative research effort between Idaho National Laboratory and Public Service Enterprise Group Nuclear, LLC. This report describes the technical basis using the Markov Process to evaluate the value proposition for the risk-informed predictive maintenance strategy for the circulating water system. The plant process data from the Salem nuclear plant’s circulating water system is utilized to develop a Markov chain risk models and formulation to estimate the loss and gain in revenue based on plant availability. The outcomes presented in this report provides the technical basis for extensive quantitative evaluation of a scalable risk-informed predictive maintenance strategy as part of future research.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mitigating commutation failures in HVDC systems with SFCL deployment

Commutation failures represent a prevalent issue encountered in line-commutated-converter high voltage direct current (LCC-HVDC) systems. As the widespread deployment of HVDC systems continues, the risk associated with commutation failures increases, posing a growing threat to power grids due to their potential to trigger severe consequences, including cascading failures and widespread blackouts. This research paper aims to address the significant issue of commutation failure within direct current (DC) systems through advocating for the use of resistive-type Superconducting Fault Current Limiters (R-SFCLs). To substantiate the efficacy of this proposed strategy, an array of simulations are executed using the PSCAD/EMTDC software. This comprehensive study investigates the performance characteristics of R-SFCLs configured with varying resistance values, scrutinizing their response under diverse fault resistance scenarios and distinct fault initiation times within the LCC-HVDC system. The outcomes of these simulations are that SFCLs confer significant advantages for mitigating commutation failures, surpassing traditional mitigation methods in terms of effectiveness. Consequently, SFCLs emerge as an optimal solution to prevent commutation failures in the HVDC systems.

Commutation failure↗

A Model Calibration Method for Grid-Forming Inverters Using Iterative Bayesian Optimization

As inverter-based resources (IBRs) are rapidly deployed, especially at the distribution and microgrid levels, the need to include their accurate representations in power systems models increases. With well-calibrated models, IBR-interactions can be examined, preventing any stability and operational issues, especially in islanded systems. This paper proposes a method to calibrate generic inverter models using Bayesian optimization, but with a parameter-grouping approach to improve speed and accuracy. This approach is illustrated for a grid-forming inverter using synthetic data and field measurements from a simple IBRbased microgrid. Tests show that the calibration algorithm has modest computation cost and is robust to noisy measurements..

Biswas, Shuchismita↗

Reactor physics benchmark of Westinghouse PWR core design suite for high burnup/high enrichment fuel - Part 2: 2D and 3D core simulations

Westinghouse has performed a comprehensive set of code-to-code benchmark comparisons to corroborate application of its state-of-the-art NEXUS-based code suite to high burnup and high enrichment (HB/HE) fueled PWR core design and reload analysis. The benchmark consisted of a progression in complexity from modeling single 2D pin cells, through 2D lattices and finally to whole core 2D and then 3D scenarios. The accompanying paper (Part 1) presented the results for a variety of pin cell and lattices representative of high energy cores and established the ability of the MPACT code to accurately match the predictions of the Monte-Carlo code SERPENT2 such that the former may be used as a surrogate reference code in spatially complex whole core modeling applications where using Monte-Carlo methods is somewhat impractical. This paper focuses on comparisons at the whole core level using a representative high power density 3-loop Westinghouse NSSS core operating for 24 month cycles employing high enriched fuel with use of combined burnable absorbers to hold down excess reactivity. The evolution of the core reactivity and power distribution characteristics throughout the cycle are calculated using the Westinghouse NEXUS-based code suite and compared to the results using MPACT. The results of this whole core benchmark confirm the conclusions that the Westinghouse code suite accurately models HB/HE fuel designs, with very good prediction of core reactivity and power distribution throughout the cycle. The industry can be confident that the NEXUS code system can be deployed to support PWR reload safety and operational analyses for cores featuring HB/HE fuel and 24-month cycle operation. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Advanced Distributed Wind Turbine Controls Series: Part 3-Wind Energy in Grid-Connected Deployments – Microgrids, Infrastructure Resilience, and Advanced Controls Launchpad (MIRACL)

In recent years the technical ability and requirement for distributed wind turbines to provide grid support services beyond maximum energy production has increased. Ancillary services leveraged through advance controls of a wind turbine support grid reliability and resilience. One ancillary service that is significant to a grid-connected wind turbine deployment is fault ride through (FRT) in response to the voltage and frequency events in the power system. As part of the Microgrids, Infrastructure Resilience, and Advanced Controls Launchpad (MIRACL) this paper demonstrates, through desktop simulations, the wind turbine's FRT capabilities to support stable grid operation. We establish that the wind turbine models exceed FRT performance requirements stipulated in IEEE 1547-2018, regarding interconnection and interoperability of distributed energy resources. Utilizing a standalone CART2 (600 kW) wind turbine connected to the NREL's Flatirons Campus grid, we study voltage and frequency FRT utilizing various test cases. One of the test cases under study is a Category III voltage fault defined in IEEE 1547-2018 and derived from CA Rule 21. Some distributed wind turbines were unable to connect to the grid following the Rule 21 enforcement in California. Even if this is not a general requirement elsewhere, the grid codes might evolve in this direction. This study illustrates how a distributed wind turbine can provide some of these FRT services and enable a pathway toward a higher contribution of renewable energy in a distribution grid.

17 WIND ENERGY↗