Search NASA⌕ Search

SEARCH · Search NASA

Results for “Design Verification”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Computer program for design and performance analysis of navigation-aid power systems

The paper examines the requirements, design rationale, operation, and verification of a computer program designated as design synthesis/performance analysis (DSPA) computer program, which is capable of performing all the calculations necessary to understand the overall characteristics of solar array/battery power systems for navigation-aid applications. Despite the uncertainties in the erratic solar array degradation data and the potential impact on actual battery behavior, verification of the DSPA is considered successful. The program is shown to have the capability of simulating the performance of solar array/battery navigation-aid power systems. It can also be used to synthesize power system designs and provide essential design and cost data.

Weiner, H.↗

JPL control/structure interaction test bed real-time control computer architecture

The Control/Structure Interaction Program is a technology development program for spacecraft that exhibit interactions between the control system and structural dynamics. The program objectives include development and verification of new design concepts - such as active structure - and new tools - such as combined structure and control optimization algorithm - and their verification in ground and possibly flight test. A focus mission spacecraft was designed based upon a space interferometer and is the basis for design of the ground test article. The ground test bed objectives include verification of the spacecraft design concepts, the active structure elements and certain design tools such as the new combined structures and controls optimization tool. In anticipation of CSI technology flight experiments, the test bed control electronics must emulate the computation capacity and control architectures of space qualifiable systems as well as the command and control networks that will be used to connect investigators with the flight experiment hardware. The Test Bed facility electronics were functionally partitioned into three units: a laboratory data acquisition system for structural parameter identification and performance verification; an experiment supervisory computer to oversee the experiment, monitor the environmental parameters and perform data logging; and a multilevel real-time control computing system. The design of the Test Bed electronics is presented along with hardware and software component descriptions. The system should break new ground in experimental control electronics and is of interest to anyone working in the verification of control concepts for large structures.

Briggs, Hugh C.↗

The Block V Receiver fast acquisition algorithm for the Galileo S-band mission

A fast acquisition algorithm for the Galileo suppressed carrier, subcarrier, and data symbol signals under low data rate, signal-to-noise ratio (SNR) and high carrier phase-noise conditions has been developed. The algorithm employs a two-arm fast Fourier transform (FFT) method utilizing both the in-phase and quadrature-phase channels of the carrier. The use of both channels results in an improved SNR in the FFT acquisition, enabling the use of a shorter FFT period over which the carrier instability is expected to be less significant. The use of a two-arm FFT also enables subcarrier and symbol acquisition before carrier acquisition. With the subcarrier and symbol loops locked first, the carrier can be acquired from an even shorter FFT period. Two-arm tracking loops are employed to lock the subcarrier and symbol loops parameter modification to achieve the final (high) loop SNR in the shortest time possible. The fast acquisition algorithm is implemented in the Block V Receiver (BVR). This article describes the complete algorithm design, the extensive computer simulation work done for verification of the design and the analysis, implementation issues in the BVR, and the acquisition times of the algorithm. In the expected case of the Galileo spacecraft at Jupiter orbit insertion PD/No equals 14.6 dB-Hz, R(sym) equals 16 symbols per sec, and the predicted acquisition time of the algorithm (to attain a 0.2-dB degradation from each loop to the output symbol SNR) is 38 sec.

Aung, M.↗

Structural Similitude and Scaling Laws

Aircraft and spacecraft comprise the class of aerospace structures that require efficiency and wisdom in design, sophistication and accuracy in analysis and numerous and careful experimental evaluations of components and prototype, in order to achieve the necessary system reliability, performance and safety. Preliminary and/or concept design entails the assemblage of system mission requirements, system expected performance and identification of components and their connections as well as of manufacturing and system assembly techniques. This is accomplished through experience based on previous similar designs, and through the possible use of models to simulate the entire system characteristics. Detail design is heavily dependent on information and concepts derived from the previous steps. This information identifies critical design areas which need sophisticated analyses, and design and redesign procedures to achieve the expected component performance. This step may require several independent analysis models, which, in many instances, require component testing. The last step in the design process, before going to production, is the verification of the design. This step necessitates the production of large components and prototypes in order to test component and system analytical predictions and verify strength and performance requirements under the worst loading conditions that the system is expected to encounter in service. Clearly then, full-scale testing is in many cases necessary and always very expensive. In the aircraft industry, in addition to full-scale tests, certification and safety necessitate large component static and dynamic testing. Such tests are extremely difficult, time consuming and definitely absolutely necessary. Clearly, one should not expect that prototype testing will be totally eliminated in the aircraft industry. It is hoped, though, that we can reduce full-scale testing to a minimum. Full-scale large component testing is necessary in other industries as well, Ship building, automobile and railway car construction all rely heavily on testing. Regardless of the application, a scaled-down (by a large factor) model (scale model) which closely represents the structural behavior of the full-scale system (prototype) can prove to be an extremely beneficial tool. This possible development must be based on the existence of certain structural parameters that control the behavior of a structural system when acted upon by static and/or dynamic loads. If such structural parameters exist, a scaled-down replica can be built, which will duplicate the response of the full-scale system. The two systems are then said to be structurally similar. The term, then, that best describes this similarity is structural similitude. Similarity of systems requires that the relevant system parameters be identical and these systems be governed by a unique set of characteristic equations. Thus, if a relation or equation of variables is written for a system, it is valid for all systems which are similar to it. Each variable in a model is proportional to the corresponding variable of the prototype. This ratio, which plays an essential role in predicting the relationship between the model and its prototype, is called the scale factor.

Simitses, George J.↗

Characterization of a novel EPID designed for simultaneous imaging and dose verification in radiotherapy

Purpose: Standard amorphous silicon electronic portal imaging devices (a-Si EPIDs) are x-ray imagers used frequently in radiotherapy that indirectly detect incident x-rays using a metal plate and phosphor screen. These detectors may also be used as two-dimensional dosimeters; however, they have a well-characterized nonwater-equivalent dosimetric response. Plastic scintillating (PS) fibers, on the other hand, have been shown to respond in a water-equivalent manner to x-rays in the energy range typically encountered during radiotherapy. In this study, the authors report on the first experimental measurements taken with a novel prototype PS a-Si EPID developed for the purpose of performing simultaneous imaging and dosimetry in radiotherapy. This prototype employs an array of PS fibers in place of the standard metal plate and phosphor screen. The imaging performance and dosimetric response of the prototype EPID were evaluated experimentally and compared to that of the standard EPID.Methods: Clinical 6 MV photon beams were used to first measure the detector sensitivity, linearity of dose response, and pixel noise characteristics of the prototype and standard EPIDs. Second, the dosimetric response of each EPID was evaluated relative to a reference water-equivalent dosimeter by measuring the off-axis and field size response in a nontransit configuration, along with the off-axis, field size, and transmission response in a transit configuration using solid water blocks. Finally, the imaging performance of the prototype and standard EPIDs was evaluated quantitatively by using an image quality phantom to measure the contrast to noise ratio (CNR) and spatial resolution of images acquired with each detector, and qualitatively by using an anthropomorphic phantom to acquire images representative of human anatomy.Results: The prototype EPID's sensitivity was 0.37 times that of the standard EPID. Both EPIDs exhibited responses that were linear with delivered dose over a range of 1–100 monitor units. Over this range, the prototype and standard EPID central axis responses agreed to within 1.6%. Images taken with the prototype EPID were noisier than those taken with the standard EPID, with fractional uncertainties of 0.2% and 0.05% within the central 1 cm{sup 2}, respectively. For all dosimetry measurements, the prototype EPID exhibited a near water-equivalent response whereas the standard EPID did not. The CNR and spatial resolution of images taken with the standard EPID were greater than those taken with the prototype EPID.Conclusions: A prototype EPID employing an array of PS fibers has been developed and the first experimental measurements are reported. The prototype EPID demonstrated a much morewater-equivalent dose response than the standard EPID. While the imaging performance of the standard EPID was superior to that of the prototype, the prototype EPID has many design characteristics that may be optimized to improve imaging performance. This investigation demonstrates the feasibility of a new detector design for simultaneous imaging and dosimetry treatment verification in radiotherapy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Risk-Informed Monitoring, Verification and Accounting (RI-MVA): An NRAP White Paper Documenting Methods and a Demonstration Model for Risk-Informed MVA System Design and Operations in Geologic Carbon Sequestration

This white paper accompanies a demonstration model that implements methods for the risk-informed design of monitoring, verification and accounting (RI-MVA) systems in geologic carbon sequestration projects. The intent is that this model will ultimately be integrated with, or interfaced with, the National Risk Assessment Partnership (NRAP) integrated assessment model (IAM). The RI-MVA methods described here apply optimization techniques in the analytical environment of NRAP risk profiles to allow systematic identification and comparison of the risk and cost attributes of MVA design options.

carbon sequestration↗

Future integrated design process

The design process is one of the sources used to produce requirements for a computer system to integrate and manage product design data, program management information, and technical computation and engineering data management activities of the aerospace design process. Design activities were grouped chronologically and explored for activity type, activity interface, data quantity, and data flow. The work was based on analysis of the design process of several typical aerospace products, including both conventional and supersonic airplanes and a hydrofoil design. Activities examined included research, preliminary design, detail design, manufacturing interface, product verification, and product support. The design process was then described in an IPAD environment--the future.

Meyer, D. D.↗

Verification of Space Station Secondary Power System Stability Using Design of Experiment

This paper describes analytical methods used in verification of large DC power systems with applications to the International Space Station (ISS). Large DC power systems contain many switching power converters with negative resistor characteristics. The ISS power system presents numerous challenges with respect to system stability such as complex sources and undefined loads. The Space Station program has developed impedance specifications for sources and loads. The overall approach to system stability consists of specific hardware requirements coupled with extensive system analysis and testing. Testing of large complex distributed power systems is not practical due to size and complexity of the system. Computer modeling has been extensively used to develop hardware specifications as well as to identify system configurations for lab testing. The statistical method of Design of Experiments (DoE) is used as an analysis tool for verification of these large systems. DOE reduces the number of computer runs which are necessary to analyze the performance of a complex power system consisting of hundreds of DC/DC converters. DoE also provides valuable information about the effect of changes in system parameters on the performance of the system. DoE provides information about various operating scenarios and identification of the ones with potential for instability. In this paper we will describe how we have used computer modeling to analyze a large DC power system. A brief description of DoE is given. Examples using applications of DoE to analysis and verification of the ISS power system are provided.

Karimi, Kamiar J.↗

Development of an advanced composite aileron for the L-1011 transport aircraft

Significant improvements in structural efficiency can be achieved by the utilization of advanced composites for construction of aircraft secondary structures. Careful evaluation of alternate designs and materials for the L-1011 advanced composite inboard aileron has led to the selection of several unique material combinations and easily manufactured structural configurations. The advanced composite aileron is a direct replacement for the metal aileron with a weight savings of 23 percent. Due to the configurational simplicity of the components within the composite aileron, and because it contains 50 percent fewer parts and fasteners than the metal aileron, it is predicted that the composite aileron will be cost competitive with the metal aileron in a production environment. Structural analysis of the composite aileron, in conjunction with the design data, concept verification, and ground tests, indicates that the composite aileron design meets or exceeds structural requirements.

Griffin, C. F.↗

Design, dynamic modeling and wave basin verification of a Hybrid Wave–Current Energy Converter

Massive and high-density Marine and Hydrokinetic (MHK) energy is contained in the ocean, including waves, tidal streams, and ocean currents. Traditional MHK energy converters harvest energy from only a single MHK energy source, which does not fully exploit the energy potential that co-exists in multiple forms of MHK energy in the ocean. This paper presents the design and dynamics of a Hybrid Wave–Current Energy Converter (HWCEC) that can simultaneously convert both wave and current energy to electricity with a single Power Take-off (PTO) through the engagement and disengagement of the three one-way clutches. The critical design parameters are analyzed through modeling and simulation, including the transmission ratios, the electrical impedance, and the turbine-heave plate distance. Water basin tests in a wave–current tank were conducted, which shows the prototyped HWCEC can improve the electric power output by 38%–71% for regular waves and 79% for irregular waves, while providing a 70% reduction of the Peak to Average Ratio (PAR) of power compared to the baseline Wave Energy Converter (WEC). Here we further analyze the occurring percentages of the instant power of both WEC and HWCEC in irregular wave tests, shedding new insight on how HWCEC reduces the PAR.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Actuation and system design and evaluation OMS engine shutoff valve, Volume 1

A technology program was conducted to identify and verify the optimum valve and actuation system concept for the Space Shuttle Orbit Maneuvering System engine. Of major importance to the valve and actuation system selection was the ten-year, 100-mission, 10,000-cycle life requirement, while maintaining high reliability, low leakage, and low weight. Valve and actuation system concepts were comparatively evaluated against past valve failure reports and potential failure modes due to the shuttle mission profile to aid in the selection of the most optimum concept for design, manufacture and verification testing. Two valve concepts were considered during the preliminary design stage; i.e., the moving seat and lifting ball. Two actuation systems were manufactured and tested. Test results demonstrate the viability of a lifting ball concept as well as the applicability of an ac motor actuation system to best meet the requirements of the shuttle mission.

Dunn, V. B.↗

Control/structure interaction design methodology

The Control Structure Interaction Program is a technology development program for spacecraft that exhibit interactions between the control system and structural dynamics. The program objectives include development and verification of new design concepts (such as active structure) and new tools (such as a combined structure and control optimization algorithm) and their verification in ground and possibly flight test. The new CSI design methodology is centered around interdisciplinary engineers using new tools that closely integrate structures and controls. Verification is an important CSI theme and analysts will be closely integrated to the CSI Test Bed laboratory. Components, concepts, tools and algorithms will be developed and tested in the lab and in future Shuttle-based flight experiments. The design methodology is summarized in block diagrams depicting the evolution of a spacecraft design and descriptions of analytical capabilities used in the process. The multiyear JPL CSI implementation plan is described along with the essentials of several new tools. A distributed network of computation servers and workstations was designed that will provide a state-of-the-art development base for the CSI technologies.

Briggs, Hugh C.↗

Camera Layout Design for the Upper Stage Thrust Cone

Engineers in the Integrated Design and Analysis Division (EV30) use a variety of different tools to aid in the design and analysis of the Ares I vehicle. One primary tool in use is Pro-Engineer. Pro-Engineer is a computer-aided design (CAD) software that allows designers to create computer generated structural models of vehicle structures. For the Upper State thrust cone, Pro-Engineer was used to assist in the design of a layout for two camera housings. These cameras observe the separation between the first and second stage of the Ares I vehicle. For the Ares I-X, one standard speed camera was used. The Ares I design calls for two separate housings, three cameras, and a lighting system. With previous design concepts and verification strategies in mind, a new layout for the two camera design concept was developed with members of the EV32 team. With the new design, Pro-Engineer was used to draw the layout to observe how the two camera housings fit with the thrust cone assembly. Future analysis of the camera housing design will verify the stability and clearance of the camera with other hardware present on the thrust cone.

Wooten, Tevin↗

Block 2 SRM conceptual design studies. Volume 1, Book 2: Preliminary development and verification plan

Activities that will be conducted in support of the development and verification of the Block 2 Solid Rocket Motor (SRM) are described. Development includes design, fabrication, processing, and testing activities in which the results are fed back into the project. Verification includes analytical and test activities which demonstrate SRM component/subassembly/assembly capability to perform its intended function. The management organization responsible for formulating and implementing the verification program is introduced. It also identifies the controls which will monitor and track the verification program. Integral with the design and certification of the SRM are other pieces of equipment used in transportation, handling, and testing which influence the reliability and maintainability of the SRM configuration. The certification of this equipment is also discussed.

Source record↗

Development of a combustor analytical design methodology for liquid rocket engines

The development of a user friendly computerized methodology for the design and analysis of liquid propellant rocket engine combustion chambers is described. An overview of the methodology, consisting of a computer program containing an appropriate modular assembly of existing industry wide performance and combustion stability models, is presented. These models are linked with an interactive front end processor enabling the user to define the performance and stability traits of an existing design (point analysis) or to create the essential design features of a combustor to meet specific performance goals and combustion stability (point design). Plans for demonstration and verification of this methodology are also presented. These plans include the creation of combustor designs using the methodology, together with predictions of the performance and combustion stability for each design. A verification test program of 26 hot fire tests with up to four designs created using this methodology is described. This testing is planned using LOX/RP-1 propellants with a thrust level of approx. 220,000 N (50,000 lbf).

Pieper, Jerry L.↗

SU-D-BRC-03: Development and Validation of an Online 2D Dose Verification System for Daily Patient Plan Delivery Accuracy Check

Purpose: All plan verification systems for particle therapy are designed to do plan verification before treatment. However, the actual dose distributions during patient treatment are not known. This study develops an online 2D dose verification tool to check the daily dose delivery accuracy. Methods: A Siemens particle treatment system with a modulated scanning spot beam is used in our center. In order to do online dose verification, we made a program to reconstruct the delivered 2D dose distributions based on the daily treatment log files and depth dose distributions. In the log files we can get the focus size, position and particle number for each spot. A gamma analysis is used to compare the reconstructed dose distributions with the dose distributions from the TPS to assess the daily dose delivery accuracy. To verify the dose reconstruction algorithm, we compared the reconstructed dose distributions to dose distributions measured using PTW 729XDR ion chamber matrix for 13 real patient plans. Then we analyzed 100 treatment beams (58 carbon and 42 proton) for prostate, lung, ACC, NPC and chordoma patients. Results: For algorithm verification, the gamma passing rate was 97.95% for the 3%/3mm and 92.36% for the 2%/2mm criteria. For patient treatment analysis,the results were 97.7%±1.1% and 91.7%±2.5% for carbon and 89.9%±4.8% and 79.7%±7.7% for proton using 3%/3mm and 2%/2mm criteria, respectively. The reason for the lower passing rate for the proton beam is that the focus size deviations were larger than for the carbon beam. The average focus size deviations were −14.27% and −6.73% for proton and −5.26% and −0.93% for carbon in the x and y direction respectively. Conclusion: The verification software meets our requirements to check for daily dose delivery discrepancies. Such tools can enhance the current treatment plan and delivery verification processes and improve safety of clinical treatments.

60 APPLIED LIFE SCIENCES↗