Search NASA⌕ Search

SEARCH · Search NASA

Results for “Detection Limit”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 613 records · Page 34

Rapid, non-destructive carbon analysis of forest soils using neutron-induced gamma-ray spectroscopy

Forest soils are pivotal to understanding global carbon (C) cycling and evaluating policies for mitigating global change. However, they are very difficult to monitor because of the heterogeneity of soil characteristics, the difficulty of representative sampling, and the slow time scale of response to environmental change. Here we demonstrate that use of gamma-ray spectroscopy facilitates in situ non-destructive analysis of C and other elements in forest soils. In this approach the element-specific gamma-rays are induced by fast and thermal neutrons interacting with the nuclei of the elements present in the soil. Background gamma-rays emanating from naturally occurring radionuclides in the forest are recorded as well. We applied this approach in a mature northern hardwood forest on glacial till soils at the Bartlett Experimental Forest in New Hampshire, USA. The inelastic neutron scattering (INS) system yielded strong signals in gamma-ray counts/h, from C and other elements present in the soil matrix that included silicon, oxygen, hydrogen, iron, aluminum, manganese and potassium. The INS sensitivity for carbon was 20.656 counts h{sup -1} kg{sup -1} C m{sup -2} based on current net C gamma-ray counts and the data for the O horizon and mineral soil to a depth of 30 cm obtained from a nearby quantitative soil pit (7.35 kg C m{sup -2}). We estimate the minimum detectable change to be {approx}0.34 kg C m{sup -2}, which is {approx}5% of the current soil C content, and the minimum detectable limit to be {approx}0.23 kg C m{sup -1}. Eight % reproducibility from 11 measurements was limited, in part, by the large variability in the system counting geometry due to the uneven forest microtopography. The INS approach has the potential to revolutionize belowground monitoring of C and other elements, because the possibility of detecting a 5% change in forest soils has not been possible with destructive sampling methods.

08 HYDROGEN↗

Direct Real-Time Detection of Vapors from Explosive Compounds

The real-time detection of vapors from low volatility explosives including PETN, tetryl, RDX and nitroglycerine along with various compositions containing these substances is demonstrated. This was accomplished with an atmospheric flow tube (AFT) using a non-radioactive ionization source and coupled to a mass spectrometer. Direct vapor detection was demonstrated in less than 5 seconds at ambient temperature without sample pre-concentration. The several seconds of residence time of analytes in the AFT provides a significant opportunity for reactant ions to interact with analyte vapors to achieve ionization. This extended reaction time, combined with the selective ionization using the nitrate reactant ions (NO3- and NO3-•HNO3), enables highly sensitive explosives detection. Observed signals from diluted explosive vapors indicate detection limits below 10 ppqv using selected ion monitoring (SIM) of the explosive-nitrate adduct at m/z 349, 378, 284 and 289 for tetryl, PETN, RDX and NG respectively. Also provided is a demonstration of the vapor detection from 10 different energetic formulations, including double base propellants, plastic explosives and commercial blasting explosives using SIM for the NG, PETN and RDX product ions.

atmospheric pressure ionization↗

A COMPACT DEGENERATE PRIMARY-STAR PROGENITOR OF SN 2011fe

While a white dwarf (WD) is, from a theoretical perspective, the most plausible primary star of a Type Ia supernova (SN Ia), many other candidates have not been formally ruled out. Shock energy deposited in the envelope of any exploding primary contributes to the early SN brightness and, since this radiation energy is degraded by expansion after the explosion, the diffusive luminosity depends on the initial primary radius. We present a new non-detection limit of the nearby SN Ia 2011fe, obtained at a time that appears to be just 4 hr after explosion, allowing us to directly constrain the initial primary radius (R{sub p} ). Coupled with the non-detection of a quiescent X-ray counterpart and the inferred synthesized {sup 56}Ni mass, we show that R{sub p} {approx}< 0.02 R{sub Sun} (a factor of five smaller than previously inferred), that the average density of the primary must be {rho}{sub p} > 10{sup 4} g cm{sup -3}, and that the effective temperature must be less than a few Multiplication-Sign 10{sup 5} K. This rules out hydrogen-burning main-sequence stars and giants. Constructing the helium-burning and carbon-burning main sequences, we find that such objects are also excluded. By process of elimination, we find that only degeneracy-supported compact objects-WDs and neutron stars-are viable as the primary star of SN 2011fe. With few caveats, we also restrict the companion (secondary) star radius to R{sub c} {approx}< 0.1 R{sub Sun }, excluding Roche-lobe overflowing red giant and main-sequence companions to high significance.

79 ASTRONOMY AND ASTROPHYSICS↗

An X-ray and radio study of steep-spectrum radio sources. II - Four fields from a 22 MHz polar cap survey

Four fields containing radio sources with spectral indices greater than unity at low frequencies have been observed over a wide range of radio wavelengths and at X-ray wavelengths. For most of the steep-spectrum sources no optical identifications have been found to the detection limit of the Palomar Schmidt prints, even with the positional precision of about 1 arcsec from VLA maps. This implies that the associated galaxies or clusters lie at a great distance. X-ray emission was not detected from any of the steep-spectrum radio sources. In one case, an extended source appears to be a radio halo in an uncataloged cluster of galaxies at a redshift of 0.125, and it is suggested that this object is a promising candidate for the detection of inverse Compton X-rays, since it is not a high-luminosity source of thermal X-rays.

Dewdney, P. E.↗

Column Optical Depth (COD) Derived from CALIOP Ocean Surface Returns

The Cloud Aerosol Lidar with Orthogonal Polarization (CALIOP) on board the Cloud Aerosol Lidar Infrared Pathfinder Satellite Observations (CALIPSO) satellite has been making near-global measurements of clouds and aerosols since mid-June 2006. Among the properties reported in CALIPSO data products are estimates of total column optical depth (COD) obtained by integrating the retrieved extinction coefficients of detected particulates (i.e., aerosols and clouds) from 36 km to the surface. However, due to algorithm detection limits and instrument sensitivities, particulates can go undetected when the particulate loading is especially diffuse or in regions where the signal is attenuated by over-lying layers. Because extinction is not calculated where features are not detected, these undetected particulates can introduce low biases into the reported COD. Lidar ratio assumptions used in the extinction retrievals can also introduce errors. To minimize these biases, future releases of the CALIPSO lidar data products will implement an ocean-derived column optical depth (ODCOD) retrieval. The following paper briefly describes the algorithm, the current status of the algorithm development and verification efforts, and preliminary comparisons to col-located COD estimates derived using other retrieval schemes and obtained from other sensors.

Robert A Ryan↗

Safeguards Verification Measurements using Laser Ablation, Absorbance Ratio Spectrometry in Gaseous Centrifuge Enrichment Plants

Laser Ablation Absorbance Ratio Spectrometry (LAARS) is a new verification measurement technology under development at the US Department of Energy’s (DOE) Pacific Northwest National Laboratory (PNNL). LAARS uses three lasers to ablate and then measure the relative isotopic abundance of uranium compounds. An ablation laser is tightly focused on uranium-bearing solids producing a small plume containing uranium atoms. Two collinear wavelength-tuned spectrometry lasers transit through the plume and the absorbance of U-235 and U-238 isotopes are measured to determine U-235 enrichment. The measurement has high relative precision and detection limits approaching the femtogram range for uranium. It is independent of chemical form and degree of dilution with nuisance dust and other materials. High speed sample scanning and pinpoint characterization allow measurements on millions of particles/hour to detect and analyze the enrichment of trace uranium in samples. The spectrometer is assembled using commercially available components at comparatively low cost, and features a compact and low power design. Future designs can be engineered for reliable, autonomous deployment within an industrial plant environment. Two specific applications of the spectrometer are under development: 1) automated unattended aerosol sampling and analysis and 2) on-site small sample destructive assay measurement. The two applications propose game-changing technological advances in gaseous centrifuge enrichment plant (GCEP) safeguards verification. The aerosol measurement instrument, LAARS-environmental sampling (ES), collects aerosol particles from the plant environment in a purpose-built rotating drum impactor and then uses LAARS-ES to quickly scan the surface of the impactor to measure the enrichments of the captured particles. The current approach to plant misuse detection involves swipe sampling and offsite analysis. Though this approach is very robust it generally requires several months to obtain results from a given sample collection. The destructive assay instrument, LAARS-destructive assay (DA), uses a simple purpose-built fixture with a sampling planchet to collect adsorbed UF6 gas from a cylinder valve or from a process line tap or pigtail. A portable LAARS-DA instrument scans the microgram quantity of uranium collected on the planchet and the assay of the uranium is measured to ~0.15% relative precision. Currently, destructive assay samples for bias defect measurements are collected in small sample cylinders for offsite mass spectrometry measurement.

Enrichment Monitoring↗

Copper oxide assisted cysteine hierarchical structures for immunosensor application

The present work describes the promising electrochemical immunosensing strategy based on copper (II) assisted hierarchical cysteine structures (CuCys) varying from star to flower like morphology. The CuCys having average size of 10 μm have been synthesised using L-Cysteine as initial precursor in presence of copper oxide under environmentally friendly conditions in aqueous medium. To delineate the synthesis mechanism, detailed structural investigations have been carried out using characterization techniques such as X-ray diffraction, transmission electron microscopy, and Fourier transform infrared spectroscopy. The electrochemical behaviour of self-assembled CuCys on gold electrode shows surface controlled electrode reaction with an apparent electron transfer rate constant of 3.38 × 10{sup −4 }cm s{sup −1}. This innovative platform has been utilized to fabricate an immunosensor by covalently immobilizing monoclonal antibodies specific for Escherichia coli O157:H7 (E. coli). Under the optimal conditions, the fabricated immunosensor is found to be sensitive and specific for the detection of E. coli with a detection limit of 10 cfu/ml.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A DEEPER LOOK AT LEO IV: STAR FORMATION HISTORY AND EXTENDED STRUCTURE

We present MMT/Megacam imaging of the Leo IV dwarf galaxy in order to investigate its structure and star formation history, and to search for signs of association with the recently discovered Leo V satellite. Based on parameterized fits, we find that Leo IV is round, with {epsilon} < 0.23 (at the 68% confidence limit) and a half-light radius of r{sub h} {approx_equal} 130 pc. Additionally, we perform a thorough search for extended structures in the plane of the sky and along the line of sight. We derive our surface brightness detection limit by implanting fake structures into our catalog with stellar populations identical to that of Leo IV. We show that we are sensitive to stream-like structures with surface brightness {mu}{sub r} {approx}< 29.6 mag arcsec{sup -2}, and at this limit we find no stellar bridge between Leo IV (out to a radius of {approx}0.5 kpc) and the recently discovered, nearby satellite Leo V. Using the color-magnitude fitting package StarFISH, we determine that Leo IV is consistent with a single age ({approx}14 Gyr), single metallicity ([Fe/H] {approx} -2.3) stellar population, although we cannot rule out a significant spread in these values. We derive a luminosity of M{sub V} = -5.5 {+-} 0.3. Studying both the spatial distribution and frequency of Leo IV's 'blue plume' stars reveals evidence for a young ({approx}2 Gyr) stellar population which makes up {approx}2% of its stellar mass. This sprinkling of star formation, only detectable in this deep study, highlights the need for further imaging of the new Milky Way satellites along with theoretical work on the expected, detailed properties of these possible 'reionization fossils'.

79 ASTRONOMY AND ASTROPHYSICS↗

Airborne Doppler radar detection of low altitude windshear

As part of an integrated windshear program, the Federal Aviation Administration, jointly with NASA, is sponsoring a research effort to develop airborne sensor technology for the detection of low altitude windshear during aircraft take-off and landing. One sensor being considered is microwave Doppler radar operating at X-band or above. Using a Microburst/Clutter/Radar simulation program, a preliminary feasibility study was conducted to assess the performance of Doppler radars for this application. Preliminary results from this study are presented. Analysis show, that using bin-to-bin Automatic Gain Control (AGC), clutter filtering, limited detection range, and suitable antenna tilt management, windshear from a wet microburst can be accurately detected 10 to 65 seconds (.75 to 5 km) in front of the aircraft. Although a performance improvement can be obtained at higher frequency, the baseline X-band system that was simulated detected the presence of a windshear hazard for the dry microburst. Although this study indicates the feasibility of using an airborne Doppler radar to detect low altitude microburst windshear, further detailed studies, including future flight experiments, will be required to completely characterize the capabilities and limitations.

Bracalente, Emedio M.↗

Inter-annual variability of net and gross ecosystem carbon fluxes: A review

As the lifetime of regional flux networks approach twenty years, there is a growing number of papers that have published long term records (5 years or more) of net carbon fluxes between ecosystems and the atmosphere. Unanswered questions from this body of work are: 1) how variable are carbon fluxes on a year to year basis?; 2) what are the biophysical factors that may cause interannual variability and/or temporal trends in carbon fluxes?; and 3) how does the biophysical control on this carbon flux variability differ by climate and ecological spaces? To address these questions, we surveyed published data from 59 sites that reported on five or more years of continuous measurements, yielding 544 site-years of data. We found that the standard deviation of the interannual variability in net ecosystem carbon exchange (162 gC m -2 y -1 ) is large relative to its population mean (-200 gC m -2 y -1 ). Broad-leaved evergreen forests and crops experienced the greatest absolute variability in interannual net carbon exchange (greater than ±300 gC m -2 y -1 ) and boreal evergreen forests and maritime wetlands were among the least variable (less than ±40 gC m -2 y -1 ). A disproportionate fraction of the yearly variability in net ecosystem exchange was associated with biophysical factors that modulated ecosystem photosynthesis rather than ecosystem respiration. Yet, there was appreciable and statistically significant covariance between ecosystem photosynthesis and respiration. Consequently, biophysical conditions that conspired to increase ecosystem photosynthesis to from one year to the next were associated with an increase in ecosystem respiration, and vice versa; on average, the year to year change in respiration was 40% as large as the year to year change in photosynthesis. The analysis also identified sets of ecosystems that are on the verge of switching from being carbon sinks to carbon sources. These include sites in the Arctic tundra, the evergreen forests in the Pacific northwest and some grasslands, where year to year changes in respiration are outpacing those in photosynthesis. While a select set of climatic and ecological factors (e.g. light, rainfall, temperature, phenology) played direct and indirect roles on this variability, their impact differed conditionally, as well as by climate and ecological spaces. For example, rainfall had both positive and negative effects. Deficient rainfall caused a physiological decline in photosynthesis in temperate and semi-arid regions. Too much rain, in the humid tropics, limited photosynthesis by limiting light. In peatlands and tundra, excess precipitation limited ecosystem respiration when it raised the water table to the surface. For deciduous forests, warmer temperatures lengthened the growing season, increasing photosynthesis, but this effect also increased soil respiration. Finally, statistical analysis was performed to evaluate the detection limit of trends; we computed the confidence intervals of trends in multi-year carbon fluxes that need to be resolved to conclude whether the differences are to be attributed to randomness or biophysical forcings. Ongoing studies and reports on interannual variations need to consider the role of the duration of the time series on random errors when quantifying potential trends and extreme events.

54 ENVIRONMENTAL SCIENCES↗

STUDIES OF THE DIFFUSE INTERSTELLAR BANDS. III. HD 183143

Echelle spectra of HD 183143 [B7Iae, E(B - V) = 1.27] were obtained on three nights, at a resolving power R = 38,000 and with a signal-to-noise ratio approx 1000 at 6400 A in the final, combined spectrum. A catalog is presented of 414 diffuse interstellar bands (DIBs) measured between 3900 and 8100 A in this spectrum. The central wavelengths, the widths (FWHM), and the equivalent widths of nearly all of the bands are tabulated, along with the minimum uncertainties in the latter. Among the 414 bands, 135 (or 33%) were not reported in four previous, modern surveys of the DIBs in the spectra of various stars, including HD 183143. The principal result of this study is that the great majority of the bands in the catalog are very weak and fairly narrow. Typical equivalent widths amount to a few mA, and the bandwidths (FWHM) are most often near 0.7 A. No preferred wavenumber spacings among the 414 bands are identified which could provide clues to the identities of the large molecules thought to cause the DIBs. At generally comparable detection limits in both spectra, the population of DIBs observed toward HD 183143 is systematically redder, broader, and stronger than that seen toward HD 204827 (Paper II). In addition, interstellar lines of C{sub 2} molecules have not been detected toward HD 183143, while a very high value of N(C{sub 2})/E(B - V) is observed toward HD 204827. Therefore, either the abundances of the large molecules presumed to give rise to the DIBs, or the physical conditions in the absorbing clouds, or both, must differ significantly between the two cases.

79 ASTRONOMY AND ASTROPHYSICS↗

Windshear detection and avoidance - Airborne systems survey

Functional requirements for airborne windshear detection and warning systems are discussed in terms of the threat posed to civil aircraft operations. A preliminary set of performance criteria for predictive windshear detection and warning systems is defined. Candidate airborne remote sensor technologies based on microwave Doppler radar, Doppler laser radar (lidar), and infrared radiometric techniques are discussed in the context of overall system requirements, and the performance of each sensor is assessed for representative microburst environments and ground clutter conditions. Preliminary simulation results demonstrate that all three sensors show potential for detecting windshear, and provide adequate warning time to allow flight crews to avoid the affected area or escape from the encounter. Radar simulation and analysis show that by using bin-to-bin automatic gain control, clutter filtering, limited detection range, and suitable antenna tilt management, windshear from wet microbursts can be accurately detected. Although a performance improvement can be obtained at higher radar frequency, the baseline X-band system also detected the presence of windshear hazard for a dry microburst. Simulation results of end-to-end performance for competing coherent lidar systems are presented.

Bowles, Roland L.↗

Mineralogical, Elemental and Tomographic Reconnaissance Investigation for CLPS (“METRIC”)

METRIC comprises a suite of two instruments in a Lunar lander that perform X-ray diffraction (XRD) for mineral structure, X-ray fluorescence (XRF) for elemental composition, and X-ray Micro Computed Tomography (XCT) for 3D internal micromorphology. The instruments are accompanied by optical-near IR cameras to provide local geologic context. The Honeybee Robotics PlanetVac pneumatic sampling and transfer system [1],positioned on a lander footpad, will deliver sieved regolith to the X-ray instruments for analysis. The instrument suite is intended for delivery to the lunar surface on a Commercial Lunar Payload Services (CLPS) lander. The METRICXRD/F instrument draws on heritage from the Mars Science Laboratory CheMin instrument [2] and improves upon the design in multiple ways [3]. Like CheMin, Rietveld refinement and full-pattern fitting of METRIC XRD data can identify minerals at a detection limit of ~1 wt.%, quantify their abundances when present at >3 wt.%, and determine mineral composition (e.g., Fo#in olivine) from lattice parameters for minerals present at >5 wt.%[4,5]. An optimized XRF geometry provides for improved detection and quantification of major, minor and trace elements. The METRIC XCT instrument is a miniaturized X-ray Computed Tomography scanner[6]. Lunar regolith is delivered to a 3 mm diameter, 10 mm long graphite tube inside the instrument. The tube is rotated through 360°in 0.9deg.incrementsand a divergent point source X-ray beam is directed through the material. A Charge Coupled Device (CCD)records attenuation images whose brightness and contrast area function of average atomic number and density. Quantitative data, including particle and void sizes, 3D particle shape parameters, modal volumes and pore geometry can be derived from the resulting 3D reconstructions(voxel resolution: 30 μm). Crystal morphologies derived from METRIC XCT data complement the bulk mineralogy determined by the METRIC XRD/F and provide a measure of grain size distribution for the different phases. Taken together, the METRIC instrument suite determines crystal structure, elemental composition and morphology, three principal characteristics of geological materials that are highly useful in determining the origin and subsequent processing of lunar regolith.

Moon↗

Dual-Readout Immunochromatographic Assay by Utilizing MnO 2 Nanoflowers as the Unique Colorimetric/Chemiluminescent Probe

Manganese dioxide nanoflowers (MnO2 NFs) were synthesized and utilized as a dual readout probe to develop a novel immunochromatographic test strip (ITS) for detecting pesticide residues using chlorpyrifos as the model analyte. MnO2 NFs-labeled antibody for chlorpyrifos was employed as the signal tracer for conducting the ITS. After 10-min competitive immunoreaction, the tracer antibody was captured by the immobilized immunogen on test line in the test strip, resulting in the accumulation of MnO2 NFs. The accumulation of MnO2 NFs led to the appearance of brown color on the test line, which could be easily observed by the naked eye as a qualitative readout. Moreover, MnO2 NFs showed a remarkably enhancing effect on the luminol-H2O2 chemiluminescent (CL) system. Unlike peroxidase-like nanomaterials, the enhancing mechanism of MnO2 NFs was based on its oxidant activity to decompose H2O2 for forming reactive oxygen species. After initiating the CL system in the test zone, strong CL signal was collected as a quantitative readout to sensitively detect chlorpyrifos. Under optimal conditions, the linear range of chlorpyrifos was 0.1–50 ng/mL with a low detection limit of 0.033 ng/mL (S/N = 3). The reliability of the dual-readout ITS was successfully demonstrated by the application on traditional Chinese medicine and environmental water samples. Due to the simultaneous rapid-qualitative and sensitive-quantitative detection, the dual-readout protocol provides a promising strategy for rapid screening and field assay on various areas such as environmental monitoring, food safety and point-of-care testing.

Ouyang, Hui↗

Nanoparticle-Based Immunochromatographic Test Strip with Fluorescent Detector for Quantification of Phosphorylated Acetycholinesterase: An Exposure Biomarker of Organophosphorous Agents

A nanoparticle-based fluorescence immunochromatographic test strip (FITS) coupled with a hand-held detector for highly selective and sensitive detection of phosphorylated acetylcholinesterase (AChE), an exposure biomarker of organophosphate (OP) pesticides and nerve agents, is reported. In this approach, OP-AChE adducts were selectively captured by quantum dot-tagged anti-AChE antibodies (Qdot-anti-AChE) and zirconia nanoparticles (ZrO2 NPs). The sandwich-like immunoreactions were performed among the Qdot-anti-AChE, OP-AChE and ZrO2 NPs to form Qdot-anti-AChE/OP-AChE/ZrO2 complex, which was detected by recording the fluorescence intensity of Qdot captured on the test line. Paraoxon was used as the model OP pesticides. Under optimal conditions, this portable FITS immunosensor demonstrates a highly linear absorption response over the range of 0.01 nM to 10 nM OP-AChE, with a detection limit of 4 pM, coupled with a good reproducibility. Moreover, the FITS immunosensor has been validated with OP-AChE spiked human plasma samples. This is the first report on the development of ZrO2 NPs-based FITS for detection of OP-AChE adduct. The FITS immunosensor provides a sensitive and low-cost sensing platform for on-site screening/evaluating OP pesticides and nerve agents poisoning.

Acetylcholinesterase↗

Sensitive and single-shot OH and temperature measurements by femtosecond cavity-enhanced absorption spectroscopy

In many low-temperature plasmas (LTPs), the OH radical and temperature represent key properties of plasma reactivity. However, OH and temperature measurements in weakly ionized LTPs are challenging, due to the low concentration and short lifetime of OH and the abrupt temperature rise caused by fast gas heating. To address such issues, this Letter combined cavity-enhanced absorption spectroscopy (CEAS) with femtosecond (fs) pulses to enable sensitive single-shot broadband measurements of OH and temperature with a time resolution of ∼180 ns in LTPs. Such a combination leveraged several benefits. With the appropriately designed cavity, an absorption gain of ∼66 was achieved, enhancing the actual OH detection limit by ∼55× to the 10 11 cm -3 level (sub-ppm in this work) compared with single-pass absorption. Single-shot measurements were enabled while maintaining a time resolution of ∼180 ns, sufficiently short for detecting OH with a lifetime of ∼100 μs. With the broadband fs laser, ∼34,000 cavity modes were matched with ∼95 modes matched on each CCD pixel bandwidth, such that fs-CEAS became immune to the laser-cavity coupling noise and highly robust across the entire spectral range. Also, the broadband fs laser allowed simultaneous sensing of many absorption features to enable simultaneous multi-parameter measurements with enhanced accuracies.

Liu, Ning↗

Spectral Aerosol Extinction (SpEx): A New Instrument for In situ Ambient Aerosol Extinction Measurements Across the UV/Visible Wavelength Range

We introduce a new instrument for the measurement of in situ ambient aerosol extinction over the 300-700 nm wavelength range, the Spectral Aerosol Extinction (SpEx) instrument. This measurement capability is envisioned to complement existing in situ instrumentation, allowing for simultaneous measurement of the evolution of aerosol optical, chemical, and physical characteristics in the ambient environment. In this work, a detailed description of the instrument is provided along with characterization tests performed in the laboratory. Measured spectra of NO2 and polystyrene latex spheres agreed well with theoretical calculations. Good agreement was also found with simultaneous aerosol extinction measurements at 450, 530, and 630 nm using CAPS PMex instruments in a series of 22 tests including non-absorbing compounds, dusts, soot, and black and brown carbon analogs. SpEx can more accurately distinguish the presence of brown carbon from other absorbing aerosol due to its 300 nm lower wavelength limit compared to measurements limited to visible wavelengths. In addition, the spectra obtained by SpEx carry more information than can be conveyed by a simple power law fit that is typically defined by the use of Angstrom Exponents. Future improvements aim at lowering detection limits and ruggedizing the instrument for mobile operation.

Jordan, C. E.↗

A SEARCH FOR DIFFUSE NEUTRAL HYDROGEN AND H I CLOUDS IN THE NGC 2403 GROUP

We have observed the NGC 2403 group of galaxies using the Robert C. Byrd Green Bank Telescope in a search for faint, extended neutral hydrogen clouds similar to the clouds found around the M81/M82 group, which is located approximately 250 kpc from the NGC 2403 group along the same filament of galaxies. For an H I cloud with a size {<=}10 kpc within 50 kpc of a group galaxy, our 7{sigma} mass detection limit is 2.2 x 10{sup 6} M {sub sun} for a cloud with a line width of 20 km s{sup -1}, over the velocity range from -890 to 1750 km s{sup -1}. At this sensitivity level, we detect three new H I clouds in the direction of the group, as well as the known galaxies. The mean velocity of the new clouds differs from that of the group galaxies by more than 250 km s{sup -1}, but are in the range of Milky Way high-velocity clouds (HVCs) in that direction. It is most likely that the clouds are part of the Milky Way HVC population. If H I clouds exist in the NGC 2403 group, their masses are less than 2.2 x 10{sup 6} M {sub sun}. We also compared our results to structures that are expected based on recent cosmological models, and found none of the predicted clouds. If NGC 2403 is surrounded by a population of dark matter halos similar to those proposed for the Milky Way in recent models, our observations imply that their H I content is less than 1% of their total mass.

79 ASTRONOMY AND ASTROPHYSICS↗