Study Of Nature Of Structural Defects In A Prussian Blue Type Cu{sub 0.73}Mn{sub 0.77}[Fe(CN){sub 6}]{center_dot}zH{sub 2}O Molecular Magnet

We have determined crystal structure and nature of structural defects in the Cu{sub 0.73}Mn{sub 0.77}[Fe(CN){sub 6}]{center_dot}zH{sub 2}O molecular magnetic compound by employing the Rietveld refinement and reverse Monte Carlo (RMC) simulation techniques on the neutron scattering data. It crystallizes in a face centred cubic structure (Space group: Fm3m). The analysis of the pair-correlation functions for the oxygen atoms of the coordinated and non-coordinated water molecules reveals a correlated local ordering of water molecules at and around the empty Fe(CN){sub 6} sites in this compound.

36 MATERIALS SCIENCE↗

A New Control System Software for SANS BATAN Spectrometer in Serpong, Indonesia

The original main control system of the 36 meter small‐angle neutron scattering (SANS) BATAN Spectrometer (SMARTer) has been replaced with the new ones due to the malfunction of the main computer. For that reason, a new control system software for handling all the control systems was also developed in order to put the spectrometer back in operation. The developed software is able to control the system such as rotation movement of six pinholes system, vertical movement of four neutron guide system with the total length of 16.5 m, two‐directional movement of a neutron beam stopper, forward‐backward movement of a 2D position sensitive detector (2D‐PSD) along 16.7 m, etc. A Visual Basic language program running on Windows operating system was employed to develop the software and it can be operated by other remote computers in the local area network. All device positions and command menu are displayed graphically in the main monitor or window and each device control can be executed by clicking the control button. Those advantages are necessary required for developing a new user‐friendly control system software. Finally, the new software has been tested for handling a complete SANS experiment and it works properly.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

KOTOBUKI-1 apparatus for cryogenic coherent X-ray diffraction imaging

We have developed an experimental apparatus named KOTOBUKI-1 for use in coherent X-ray diffraction imaging experiments of frozen-hydrated non-crystalline particles at cryogenic temperature. For cryogenic specimen stage with small positional fluctuation for a long exposure time of more than several minutes, we here use a cryogenic pot cooled by the evaporation cooling effect for liquid nitrogen. In addition, a loading device is developed to bring specimens stored in liquid nitrogen to the specimen stage in vacuum. The apparatus allows diffraction data collection for frozen-hydrated specimens at 66 K with a positional fluctuation of less than 0.4 μm and provides an experimental environment to easily exchange specimens from liquid nitrogen storage to the specimen stage. The apparatus was developed and utilized in diffraction data collection of non-crystalline particles with dimensions of μm from material and biological sciences, such as metal colloid particles and chloroplast, at BL29XU of SPring-8. Recently, it has been applied for single-shot diffraction data collection of non-crystalline particles with dimensions of sub-μm using X-ray free electron laser at BL3 of SACLA.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ptychographic x-ray imaging of surfaces on crystal truncation rod

Ptychography is a high-resolution imaging technique, which does not require lenses for image magnification and which provides phase contrast with high sensitivity. Here, we propose to use x-ray ptychography for the imaging of surface structure in crystalline samples. We show that ptychography can be used to image atomic step structures using coherent diffraction patterns recorded along the crystal truncation rod of a crystal surface. In a proof-of-concept experiment on a Pt (111) sample, we present ptychographic reconstructions showing features consistent with surface steps. Due to the penetration power of x-rays, this method could find interesting applications for the study of surface structures under buried interfaces or in harsh environments.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

New developments in micro-X-ray diffraction and X-ray absorption spectroscopy for high-pressure research at 16-BM-D at the Advanced Photon Source

We report the monochromator and focusing mirrors of the 16-BM-D beamline, which is dedicated to high-pressure research with micro-X-ray diffraction (micro-XRD) and X-ray absorption near edge structure (XANES) (6-45 keV) spectroscopy, have been recently upgraded. Monochromatic X-rays are selected by a Si (111) double-crystal monochromator operated in an artificial channel-cut mode and focused to 5 μm × 5 μm (FWHM) by table-top Kirkpatrick-Baez type mirrors located near the sample stage. The typical X-ray flux is ~5 × 10 8 photons/s at 30 keV. The instrumental resolution, Δq/q max , reaches to 2 × 10 –3 and is tunable through adjustments of the detector distance and X-ray energy. The setup is stable and reproducible, which allows versatile application to various types of experiments including resistive heating and cryogenic cooling as well as ambient temperature compression. Transmission XANES is readily combined with micro-XRD utilizing the fixed-exit feature of the monochromator, which allows combined XRD-XANES measurements at a given sample condition.

47 OTHER INSTRUMENTATION↗

Interfacial stability of ultrathin films of magnetite Fe 3 O 4 (111) on Al 2 O 3 (001) grown by ozone-assisted molecular-beam epitaxy

Thin films of iron oxides including magnetite (Fe 3 O 4 ) and hematite (α-Fe 2 O 3 ) have many important applications. Both forms of oxide can occur naturally during film growth by iron deposition under various oxidation environment; an important issue is to understand and control the process resulting in a single-phase film. We have performed in-situ real-time studies using x-ray diffraction of such film growth on sapphire (001) under pure ozone by monitoring the (00L) rod. Stable magnetite growth can be maintained at growth temperatures below 600° C up to a certain critical film thickness, beyond which the growth becomes hematite. The results demonstrate the importance of interfacial interaction in stabilizing the magnetite phase.

36 MATERIALS SCIENCE↗

Synthesis of greigite (Fe 3 S 4 ) particles via a hydrothermal method

Greigite (Fe 3 S 4 ) particles, with strong ferrimagnetic behavior, have been found to have desirable uses in the areas of biomedical and environmental applications. Size-dependent magnetic properties of greigite can play a crucial role in efficiency of its applications. This study reviews two synthetic approaches to producing such particles. The methods tested within this study include a coprecipitation synthesis and a hydrothermal process. While the coprecipitation method proved to be ineffective at producing greigite, the hydrothermal process showed promise after consistently producing greigite. For the hydrothermal process, the effects of synthesis time, autoclave atmosphere, and polyvinylpyrrolidone (PVP) addition as a capping agent to control particle growth were investigated using X-ray diffractometry (XRD) with Rietveld refinement, vibrating sample magnetometry (VSM), and scanning electron microscopy (SEM). The results show that, while pyrite (FeS2) forms as an impurity phase, increasing the synthesis time up to 18 hours increases the greigite fraction up to 70 wt% and saturation magnetization up to ~ 35 emu/g for the powder synthesized in argon. The SEM micrographs of this sample reveal a mean greigite particle size of ~ 700 nm. It was found that adding PVP brings about a much more uniform microstructure of agglomerated plate-shape particles with nano-sized features.

36 MATERIALS SCIENCE↗

Determination of the dehydration pathway in a flexible metal–organic framework by dynamic in situ x-ray diffraction

Understanding guest exchange processes in metal–organic frameworks is an important step toward the rational design of functional materials with tailor-made properties. The dehydration of the flexible metal-organic framework [Co(AIP)(bpy)0.5(H2O)]•2H2O was studied by novel in situ dynamic x-ray diffraction techniques. The complex mechanism of dehydration, along with the as-yet unreported metastable structures, was determined. The structural information obtained by the application of these techniques helps to elucidate the important guest–host interactions involved in shaping the structural landscape of the framework lattice and to highlight the importance of utilizing this technique in the characterization of functional framework materials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Pressure-induced phase transition in barium hydride studied with neutron scattering

Barium hydride can undergo a structural phase transition from an orthorhombic phase to a hexagonal phase induced by high temperature or high pressure. This transition causes an immediate increase in the hydrogen diffusion rates by over an order of magnitude, and therefore, understanding the origin and details of such transition is of great interest not only for fundamental reasons but also for improving materials for future applications. In this work, the pressure evolution of the crystal structure was characterized using neutron powder diffraction up to a maximum pressure of 11.3 GPa. The pressure dependence of the unit cell volumes, lattice parameters, atomic sites, and compressibilities were determined for both phases. A structural phase transition occurred over a wide pressure range of P = 1.3 GPa–4.9 GPa. The transition to the higher density hexagonal phase reduced the volume per formula unit of BaD 2 by 13.6%, hence increasing the volumetric storage density. In addition, we investigated the hydrogen diffusion process using high pressure quasi-elastic neutron scattering up to 7.1 GPa. Our results show that the hydrogen mobility increases with pressure in the hexagonal phase. This work sheds light on the structural and dynamical aspects of barium hydride caused by the application of high pressure. Finally, the results may aid in the development of advanced metal hydride systems with increased hydrogen dynamics.

36 MATERIALS SCIENCE↗

In situ x-ray and electron scattering studies of oxide molecular beam epitaxial growth

We perform the first in situ synchrotron X-ray ray diffraction (SXRD) / reflection high energy electron diffraction (RHEED) studies on the growth of complex oxide thin films by molecular beam epitaxy. The unique deposition chamber, located at the Advanced Photon Source, allows the preparation of complex oxide samples with monolayer precision and facilitates the formation of direct correlations between in situ X-ray studies and the more prevalent RHEED investigations. Importantly, because SXRD and RHEED probe different atomic-scale processes during thin film synthesis, their concomitant use enables the extraction of details concerning growth behavior than one cannot determine from either probe alone. We describe the results of such in situ studies on the epitaxial growth of perovskite LaNiO3on (La 0.18 Sr 0.82 )(Al 0.59 Ta 0.41 )O 3 (001). We find that during the earliest stages of growth, the RHEED and X-ray signals do not agree with each other, demonstrating that while regular RHEED oscillations may imply high quality growth, the film-substrate interface can undergo significant changes during deposition due to the occurrence of interdiffusion at the growth temperature.

36 MATERIALS SCIENCE↗

CENTAUR - The small- and wide-angle neutron scattering diffractometer/spectrometer for the Second Target Station of the Spallation Neutron Source

CENTAUR has been selected as one of the eight initial instruments to be built at the Second Target Station (STS) of the Spallation Neutron Source at Oak Ridge National Laboratory. It is a small-angle neutron scattering (SANS) and wide-angle neutron scattering (WANS) instrument with diffraction and spectroscopic capabilities. This instrument will maximally leverage the high brightness of the STS source, the state-of-the-art neutron optics, and a suite of detectors to deliver unprecedented capabilities that enable measurements over a wide range of length scales with excellent resolution, measurements on smaller samples, and time-resolved investigations of evolving structures. Notably, the simultaneous WANS and diffraction capability will be unique among neutron scattering instruments in the United States. This instrument will provide much needed capabilities for soft matter and polymer sciences, geology, biology, quantum condensed matter, and other materials sciences that need in situ and operando experiments for kinetic and/or out-of-equilibrium studies. Beam polarization and a high-resolution chopper will enable detailed structural and dynamical investigations of magnetic and quantum materials. CENTAUR’s excellent resolution makes it ideal for low-angle diffraction studies of highly ordered large-scale structures, such as skyrmions, shear-induced ordering in colloids, and biomembranes. Additionally, the spectroscopic mode of this instrument extends to lower momentum transfers than are currently possible with existing spectrometers, thereby providing a unique capability for inelastic SANS studies.

47 OTHER INSTRUMENTATION↗

Similarity in the critical thicknesses for superconductivity and ferroelectricity in strained SrTiO 3 films

The possible connection between superconductivity and polar order in SrTiO 3 has been discussed extensively in the recent literature. Here, the thickness dependence of the superconducting and ferroelectric transitions in strained, epitaxial films of SrTiO 3 films is studied. Both superconductivity and ferroelectricity are absent in thinner films (25 nm and below). Here, we discuss the possible origins of the thickness dependence of both phenomena.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Low-temperature formation of Ti2AlN during post-deposition annealing of reactive multilayer systems

M n+1 AXn-phase Ti 2 AlN thin-films were synthesized using reactive sputtering-based methods involving the deposition of single-layer TiAlN, and Ti/AlN and TiN/TiAl multilayers of various modulation periods at ambient temperature and subsequent annealing at elevated temperatures. Ex situ and in situ x-ray diffraction measurements were used to characterize the Ti 2 AlN formation temperature and phase fraction. During annealing, Ti/AlN multilayers yielded Ti 2 AlN at a significantly lower in situ temperature of 650 °C compared to TiN/TiAl multilayers or single-layer TiAlN (750 °C). The results suggest a reactive multilayer mechanism whereby distinct Ti and AlN layers react readily to release exothermic energy resulting in lower phase transition temperatures compared to TiN and TiAl layers or mixed TiAlN. With a modulation period of 5 nm, however, Ti/AlN multilayers yielded Ti 2 AlN at a higher temperature of 750 °C, indicating a disruption of the reactive multilayer mechanism due to a higher fraction of low-enthalpy interfacial TiAlN within the film.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

High-pressure cells for in situ multi-anvil experiments

A new series of high-pressure cells for in situ multi-anvil experiments is described. The cells are based on the conventional COMPRES cells, but modifications are made to improve the passage of X-rays. The modifications include cutting slits in parts of the assemblies that have very high X-ray absorption, such as lanthanum chromite and rhenium, the use of low-Z thermal insulation, such as forsterite, in place of zirconia, and the partial replacement of zirconia by MgO equatorial windows combined with a mullite octahedron. Details of the designs, thermal characterizations, and examples of the application of these cells are described.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Using angular dispersion and anomalous transmission to shape ultramonochromatic x rays

Optical spectrometers, instruments that work with highly monochromatic light, are commonly rated by the spectral bandwidth, which defines the ability to resolve closely spaced spectral components. Another equally important feature is the spectral contrast, the ability to detect faint objects among these components. Here we demonstrate that a combined effect of angular dispersion (AD) and anomalous transmission (AT) of x rays in Bragg reflection from asymmetrically cut crystals can shape spectral distributions of x rays to profiles with high contrast and small bandwidths. The AD and AT x-ray optics is implemented as a five-reflection, three-crystal arrangement featuring a combination of the above-mentioned attributes so desirable for x-ray monochromators and analyzers: a spectral contrast of {approx_equal} 500, a bandwidth of {approx_equal} 0.46 meV, and a remarkably large angular acceptance of {approx_equal} 107 {mu}rad with 9.1 keV x rays. The new optics can become a foundation for the next-generation inelastic x-ray scattering spectrometers for studies of atomic dynamics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Observations of Shock-Loaded Tin and Zirconium Surfaces with Single-Pulse X-ray Diffraction

A single-pulse X-ray diffraction (XRD) diagnostic has been developed for the investigation of shocked material properties on a very short time scale. The diagnostic, which consists of a 37-stage Marx bank high-voltage pulse generator coupled to a needle-and-washer electron beam diode via coaxial cable, produces line-and-bremsstrahlung X-ray emission in a 40 ns pulse. The molybdenum anode produces 0.71 Å characteristic K lines used for diffraction. The X-ray beam passes through a pinhole collimator and is incident on the sample with an approximately 2 mm×5 mm spot and 1° full width at half maximum angular divergence. Coherent scattering from the sample produces a Debye-Scherrer diffraction pattern on an image plate located at 75 mm from the polycrystalline sample surface. An experimental study of the polycrystalline structures of zirconium and tin under high-pressure shock loading has been conducted with single-pulse XRD. The experimental targets were 0.1-mm-thick foils of zirconium and tin using 0.4-mm-thick vitreous carbon back windows for shock loading, and the shocks were produced by either Detasheet or PBX-9501 high explosives buffered by 1-mm-thick 6061-T6 aluminum. The diffraction patterns from both shocked zirconium and tin indicated a phase transition into a polymorphic mix of amorphous and new solid phases.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Instrumentation and Samples (CRADA Final Report)

Instruments which are categorized as shared user instruments at the National Laboratory of the Rockies (NLR) will be utilized for ongoing technical work. Samples will be provided by University of Colorado Boulder (CU) and thus no need for materials at NLR is anticipated.

(Ga1- xZnx)(N1-xOx)↗